ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: SW940119 PID Number: 051-792-02
Page 1 of 3
• (907) 343-7904
p New ❑ Upgrade
Name:
STEVE C & MANDY POGANY
ABSORPTION FIELD
Address -
21245 OBERG
✓
❑ Deep Trench ❑Shallow Trench Bed ❑Mound
❑ Other
Phone
Number of Bedrooms
4
Soil Rating
0.8GPD/SF
Total depth from original grade .
8.0 R.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Gravel depth beneath pipe
Subdivision Block Lot
MCKINLEY VIEW EST
3 Ft.
5.0Ft.
1 2
Fill added above original grade
Gravel length
Township Range Section
0 Ft:
77.1 Ft.
Gravel width
Beds: Number of Lines
Distance between lines
SEPARATION DISTANCES
2.5Ft.
Pt.
To
From
Septic
Tank
Absorption
Field
Lift Station
Holding
Tank
Sewer
Line
Total absorption area
7701
Fiz
Number of trenches
Dist. between trenches
N/A Ft.
Well
200+
200+
N/A
N/A
200+
TANK l Septic 0 S.T.E.P. 0 Holding 0 Other
Manufacturer
Capacity
Surface Water
100+
100+
N/A
N/A
ANCHORAGE TANK(Assc.vree_S
1250GaI.
Material
Number of compartments
Lot Line
26.2
2642
N/A
N/A
NA
STEEL
2
Foundation
39.6
57.7
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
N/A
N/A
N/A
N/A
Gal.
Remarks
-Aocv,nc[9..,�'.—A-i7ov dt= 5'Tic —�.-I
Pump on level at
Pump off level at
High water alarm at
tiUSiriatL&j Op4Do2'P fr1ir c.ii @t flet
- in.
in.
in.
Pump make and model
Electrical Inspections performed by
Installer
PIPE MATERIAL House to tank Tankto
3034 grainfield 3034
ld
UNtk,"Vow 0-
Drainfield 3034 CO/MT 3034
Inspector Pannone Engineering Services
BENCH MARK (Assumed elevation) 100ft
Inspection,
dates: fn 10/30/14 2nd 11/4/14
Location and descri tion
p
aid aln
Corner of house trim
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Conditional Approval: Date -•
Engineer's Stamp
• `!V
Approv-d / �, Date I f Id
I
even .Dqa.nn. I• gliC b9 '`
r
q
oma
\1»ez"C,•
_1 -1 -IL.
0
0
w Q
0 O
O CC
LOT 3
LOT 4
PRIMARY DRAIN FIELD
77.1 LF X 2.5' WIDE, 5.0' E.D., 9' TD
/
/
T&E EASEME
/
DRIVEWAY
NOTES:
RECORD DRAWING
PLAN
LOT 1
1250 GAL SEPTIC TANK
CLASS A WATER SERVICE
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AI 99510
PHONE (907) 272-8218 FAX (907) 272-8211
SUMMIT ESTATES, BLK 2, LOT 9
CRAIG WILSON
5401-5439 SUMMIT ST
ANCHORAGE, AK 99507
(e OF A.•L4kk�
Arca;
*4' %\ . . *SII
�`a�
Steven Pannor3e j
-2,2eL CE 8149
I10IV•
f'ROFES510� �//
Date
11/6/2014
Scale
P.I.D. NO
051-792-02
PERMIT NO
SW940119
Sheet
2 OF 3
A
B
FC
4.2
-
T1
40.3
53.4
T2
48.1
60.8
DCO
50.0
62.7
01
86.1
69.0
M1
85.2
68.4
C2
65.7
76.3
M2
66.1
69.0
/
/
T&E EASEME
/
DRIVEWAY
NOTES:
RECORD DRAWING
PLAN
LOT 1
1250 GAL SEPTIC TANK
CLASS A WATER SERVICE
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AI 99510
PHONE (907) 272-8218 FAX (907) 272-8211
SUMMIT ESTATES, BLK 2, LOT 9
CRAIG WILSON
5401-5439 SUMMIT ST
ANCHORAGE, AK 99507
(e OF A.•L4kk�
Arca;
*4' %\ . . *SII
�`a�
Steven Pannor3e j
-2,2eL CE 8149
I10IV•
f'ROFES510� �//
Date
11/6/2014
Scale
P.I.D. NO
051-792-02
PERMIT NO
SW940119
Sheet
2 OF 3
SPECIAL PROVISIONS TO SPECIFICATIONS
. ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE
STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE
WASTEWATER DISPOSAL SYSTEMS AND ATTACHED FES SPECIAL PROVISIONS.
3 SCOPE OF WORK: INSTALLED NEW 1250 GAL SEPTIC TANK AND SOIL ABSORPTION SYSTEM.
4. GROUNDWATER WAS NOT ENCOUNTERED BELOW EXISTING GRADE IN ANY OF THE EXCAVATIONS LESS THAN 15 FEEL
TEST HOLE 1
ELEV. 94.3
IILLTER FABRIC
%550Nt�6
4" 0 PERF PIPE
DRAIN ROCK 6" ABOVE PIPE INV
3.0
DRAIN ROCK
140
0
0
U
43
ELEV- 93.25
0
0
w
U
1250 g SEPTIC
TANK (14lE
s
w0
0<
0W
cLa
0U
FLOWSPLITTER
PIiE INV. ELEV. 91.3
5080
ISOT ELEV. 96.3
SECTION
CO
o • I_
< • O
U
FILTER FABRI
C AssUtWcTh)
4" 0 PERF PIPE
DRAIN ROCK 6"
ABOVE PIPE INV
1 MONITOR TUBE
TOP OF PIPE ELEV. 91.6
DESIGN PARAMETERS
PRIMARY/RESERVE SEPTIC SYSTEM
NO. BEDROOM: 4 (600 gpd)
TANK SIZE: 1250g SEPTIC TANK
PERC RATE = 9 MPI
SOIL RATING: 0.8 GPD/SF
AREA ROD: 750 SF
SYS. TYPE: DEEP TRENCH 5.0'ED
RE:—
MIN LENGTH: 75 LF
USED:
77.1 LF X 2.5 WIDE, 5.0' E.D., 8.0. TD
TOTAL AREA: 771 SF
INV. ELEV. 92.50
PROFILE
W
ss
DRAIN ROCK�Z'_�',-_- 3.
`.
TRENCH SEE DESIGN
LEGEND
WATER LINE/
WELL RADIUS
NEW SEPTIC
PIPE INV. ELEV. 91.3
BOT ELEV. 96.3
ABBREVIATIONS
Cu
DIP
TH
FC
T#
C#
M#
R.I.
DCO
DV
FS
BFG
OG
COPPER
DUCTILE IRON PIPE
TEST HOLE
FOUNDATION CLEAN OUT
TANK CLEAN OUT NO.
CLEAN OUT NO.
MONITOR TUBE NO.
RIGID INSULATION
DOUBLE CLEAN OUT
DIVERTER VALVE
FLOW SPLITTER
BELOW FINISH GRADE
ORIGINAL GRADE
PG FINISH GRADE
TS&V TOPSOIL & VEGETATE
NOTES
RECORD DRAWING
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
DESIGN DETAILS
SUMMIT ESTATES, BLK 2, LOT 9
CRAIG WILSON
5401-5439 SUMMIT ST
ANCHORAGE, AK 99507
J' -Se • OF ACgsl10
AC,s
• . Steven •RTPannome
V.•. CE 8149 • .•��%
��l1kupPRoFEssoot-z-
Date
11/6/2014
Scale
NTS
P.I.D. NO
02
PERMIT NO.
SW940119
Sheet
3OF3
69-991 3d 'OSLO
3JI UO/UNV MONS 3AISS3
<MIA HI
\�)k/§co
OBE G ROAD
071
)/j§(.{
rl
.§/`\1-1
nZ, 7C FM 2
\�\ODD
\\1712
MUNICIPALITY OF ANCHORAGE
Development Services Department r Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 051-792-02
Legal description McKinley View Estates Block 1 lot 2
Site address 21245 Oberg Rd Chugiak
Current property owner(s) Michael & Lisa Watson
Expiration Date: 7-11-2023
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
9-2-22
By: 1ti (� ; Original Certificate Date:
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA Approval_June 2022
MUMUPALJTY O HCFC --AOR G
Development Services Department - T Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 051-792-02
Complete legal description McKinley View Estates, Block 1 Lot 2
Location (site address) 21245 Ober'g Road, Chugiak, AK 99567
Current property owner(s) Michael & Lisa Watson Day phone
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units 0 Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ®❑ Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: 0 Steel ❑ Plastic ❑ Concrete ❑ Fiberglass
Age 8 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed 0 Deep Trench ❑ Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee / Waiver Fee $
Date of Payment �/ 3 f%� Z Date of Payment
COSA # Waiver #
COSA Application_June 2022
Legal Description: McKinley View Estates Block 1 Lot 2 Parcel ID: 051-792-02
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system
A. WELL DATA
L VII, oq is filed with Onsite (or attached)
Date drilled _ Total depth ft
Cased to ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Well production at time of test gpm
Water storage tank volume gallons
Well disinfected for coliform test? ❑ Yes ❑ Nc
❑ Coliform bacteria is Negative
itrate mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by
Static water level at beginning of test ft. Date
Comments Serviced by a Class A Well PWSID# 210697
B. TANK DATA
Measured operating fluid level in septic tank
Date of pumping 6/29/22 Sanitary Pumpers
❑ Required maintenance completed, if AWWTS
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) After 6/19/1994
❑ ALL standpipes present per record drawing
Total measured depth from grade 6.6 ft (max)
Measured depth to pipe invert from grade 1.6 ft (min)
❑ N/A — pressurized field.
❑ Per record drawings, field is insulated.
❑ Monitor tubes go to bottom of effective.
If not, state depth into effective
❑ Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months)
If yes, enter date
Comments/Deficien
COSA Checklist June 2022
C. LIFT STATION
HRem ed maintenance completed
Age of lift station ears
Lift station material
Comments:
Adequacy test date 7/11/22
Results g Pass
Fluid depth prior to test
633
27 in
Water added gal
New fluid depth 38 in
Elapsed time 1440 min
Final fluid depth 26 in
Absorption rate >600 gpd
FIELD STATUS — POST RECOVERY
Effective depth (per record drawings) 60 in
Effective depth used 27 in
Effective depth remaining 33 in
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Se tip nk/Lift Station on Lot > 100' NSA Community Sewer Manhole/Cleanout > 100'
❑Yes if No ft Ely- if No NSA ft
Neighboring Tank > 100' if No NSA ft Private Sewer/Septic Line > 25' ❑ Yes if No NSA ft
Absorption Field on Lot > 100' ❑ Yes if No Holding Tank > 100' Yes if No NSA ft
Neighboring Absorption Fields > 100' NSA Animal Con nt > 50' ❑Yes if No NSA ft
❑ Yes if No ft
Manure/Animal Excreta Storage �_ 1
Community Sewer Main > 75' ❑ Yes if No NSA ft ❑ Yes i NSA ft
❑ N/A — Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10' 0 Yes if No ft Surface Water > 100' 0 Yes if No ft
Tank to Property Line > 5'
Fn� Yes
if No ft
Field to Property Line > 10'
no Yes
if No ft
Water Main > 10'
❑m Yes
if No ft
Water Service Line > 10'
0 Yes
if No ft
F. ENGINEER'S COMMENTS
Wells on Adjacent Lots:
Private Wells > 100'
Community Wells > 200'
r-0-1 Yes if No ft
Qm Yes if No ft
If tank or field is under driveway comment below
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm Forge Engineering
Engineer's Printed Name Benjamin Schiller, P.E.
COSA Checklist June 2022
Phone (907) 522-7773
Date 8/29/22
OF
*. qg TM
• • ' Benjarr�ryy chiller , ' • .
I �F� • • CE 12592AW
�`nt�c • . . • '�v
��l�i�pROf E3S10N����
RUSH
• Municipality of Anchorage
41, On -Site Water and Wastewater Program
�+ (907) 343-7904
Certificate of On -Site Systems Approval
Parcel I.D. 051-792-02
Expiration Date:
1. GENERAL INFORMATION
Complete legal description McKinley View Est. Block 1, Lot 2
Location (site address) 21245 Oberg Rd.
Current Property owner(s) Steve & Mandy Pogany Day phone
Mailing address PO Box 672362 Chugiak, AK 99567
Real Estate Agent Day phone
2. TYPE OF DWELLING:
E Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3: NUMBER OF BEDROOMS:
4
SUBMITTAL
NOV 122014
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well ❑ Individual 0
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System El Public Sewer ❑
WaiverNariance request for: Distance:
Received b •
COSA to be released to the engineer, unless otherwise requested by the engineer.
Date: Z
stn r
COSA Fee $ 524-F 3``15.(a t:?"4 .SSD Waiver Fee $
Date of Payment 1t 112-114 (1/2- Date of Payment
Receipt Number Ob`jib & Receipt Number
COSA# 05Ct4 1SJlo Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined
in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater
disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply
and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at
the time of installation.
In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA COSA
guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test,
and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil
condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions
are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future
performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty
for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed
above.
Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218
Address P.O. Box 100217, Anchorage Ak. 99510
Engineer's Printed Name Steven R Pannone
6. DSD SIGNATURE
System #1 Approved for bedrooms seven �2'.''onnone
CE -8149 .
System #2 Approved for bedrooms�
Disapproved %OFE39
Date 10/30/2014
e0? '
,/*: 49TH
Conditional approval for bedrooms, with the following stipulations:
`J2 ON-51it
`t WATAND
ro WASTEREWATER o^
-t9 0PflGRAM
NT SER`\ ���
»))))»)1`
e/
(W� r
kililii J1-1
Original Certificate Date: I) i /`C ( ,
r a
e Jnicipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet_c
If more than 1 septic system is on the lot:
COSA Checklist # 1 of 1
Structure served by this system 1
Certificate of On -Site Systems Approval Checklist
Legal Description: McKinley View Est. Block 1, Lot 2 Parcel ID: 051-792-02
A. WELL DATA
Well type CiaSS A' If A, B, or C provide PWSID # I c 7 Well Log (Y/N)
Date completed Sanitary seal (Y/N) Wires properly protected (Y/N)
Total depth ft. Cased to ft. Casing height (above ground) in.
FROM WELL LOG AT INSPECTION
Date of test
Static water level ft. ft.
Well production g.p.m. g.p.m.
WATER SAMPLE RESULTS:
Coliform colonies/100 mL Nitrate mg/L
Arsenic
ug/L Date of sample: Collected by:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel Date installed After 6/19/1994
Tank size 1,250
gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N
Date of pumping 10/31/2014 Pumper Sanitary Pumpers
C. ABSORPTION FIELD DATA
Date installed
After 6/19/1994 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.8 GPD/SF System type Deep Trench
Length 77.1 ft. Width 2.5 ft. Gravel below pipe 5 ft.
Total depth 8 ft. Eff. absorption area 770 ft2 Monitoring tube Y Depression over field N
Date of adequacy test 10/30/2014 Results (Pass/Fail) Pass For 4 bedrooms
Fluid depth in absorption field before test 13 in. Water added 606 gal. New depth 33 in.
Elapsed Time: 310 min. Final fluid depth 13 in. Absorption rate >= 600+ g.p.d.
No
Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date
D. LIFT STATION
Date installed Size in gallons
"Pump on" level at in. "Pump off' level at in.
Datum Cycles tested
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
Sewer /septic service line
Animal containment areas
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5+ Property line 5+
Water main 10+
Wells on adjacent lots 100+
ABSORPTION FIELD ON LOT TO:
Manhole/Access (Y/N)
High water alarm level at in.
Meets alarm & circuit requirements?
On adjacent lots
On adjacent lots
Public sewer manhole/cleanout
Holding tank
Manure/animal excrete storage areas
Absorption field 5+
Water service line 10+ Surface water 100+
Property line 10+ Building foundation 10+
Water Service line 10+
Water main 10+
Surface water 100+ Driveway, parking/vehicle storage 10+
Curtain drain 50+ Wells on adjacent lots 100+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
1 certify that I have determined through field inspections and
reviewof Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Steven R. Pannone
Date 10/30/2014
COSA brown sheet 10-10-12.doc
'f'fi
*+
10 • keven 12. Pannonee. .
r0
David R. Dayton P.E.
20210 Donalar St.
Chugiak, Alaska 99567
SUBJECT
/
T iz
65.7,9
DATI
e::, 14
//$
RECEIVED
JON 1 41994
Municipality of Anchorage
Dept. Health & Human Services
POLY PI (50 SETS) 4P460
1 HO I4EllY WC,
`ilf;�fLl3
It;5.111b
Rick Mystrom,
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
May 9, 1995
Gary C. Pogany
PO Box 770323
Eagle River, Alaska 99577
Subject: Lot 2 Block 1 Mc Kinley View Estates Subdivision
Permit #SW940119, PID #051-792-02
The subject permit, issued May 9, 1994 by this office for a
single family well and/or on-site wastewater system, has
expired as of May 9, 1995.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as -built inspection report must be sent to this office for
review, approval and documentation. All inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
cerely,
�GJ `,
ames Cross, P.E.
rogram Manager
On-site Services
enc: Copy of Permit
cc: Mary Dayton
hs
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW940119
DESIGN ENGINEER:DAVID R. DAYTON, P.E.
OWNER NAME:POGANY GARY C &
OWNER ADDRESS:P.O. BOX 770323
EAGLE RIVER, AK 99577
PARCEL ID:05179202
LEGAL DESCRIPTION: MCKINLEY VIEW ESTATES BLK 1
LT 2
LOT SIZE: 31696 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
PAGE 1 OF 1
DATE ISSUED: 5/09/94
EXPIRATION DATE: 5/09/95
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 (24 HOURS) .
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY:
ISSUED BY: ('c
DATE: 'OA /
6 DATE: G' 04''',
L p --r- Z. 1 Nick, &• \1, e.„.4 csT
4--'-� SPA
Ana
GA 4-0.44_
—�� 1l l%i to 8grAl/s 1
3�. w 75'0 sa
8 + oc.ia-'
1
go
2 a
zXs
e/5 eF
0
J5
5 cov rt.,
oe/4iNAf-
4 Ff^+w/e-^ed
X16
4'
/0'
11 0 w nom- 1220 u..1n
�T Z FJ Ly-
I `/ 1c, 1,3 Ls,/ V l e3 E`aT,
6//3/95 OFrvi s az" A-1.,
David R. Dayton P.E.
20210 DonaIar St.
Chugiak, Alaska 99567
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW940119
DESIGN ENGINEER:DAVID R. DAYTON, P.E.
OWNER NAME:POGANY GARY C &
OWNER ADDRESS:P.O. BOX 770323
EAGLE RIVER, AK 99577
PARCEL ID:05179202
LEGAL DESCRIPTION: MCKINLEY VIEW ESTATES BLK 1
LT 2
LOT SIZE: 31696 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
PAGE 1 OF 1
DATE ISSUED: 5/09/94
EXPIRATION DATE: 5/09/95
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIQNS:
RECEIVED BY
ISSUED BY:
DATE:
DATE:
Lar , IVICilNwy \/1C--uJ T
3 4-3-® pa ooc)gcJ
Eto
.5744 LA
C/se ®c,=
t.TEbT ,FML-.
1.10 w P.--T-Gat— 10.0 U
Z FLL-14-.
Mcg Iry LA'S/ Ni 1 eu3 E r.
David R.DayBon P•E.
10210 Denalar St.;
Chugiak, Alaska 99567
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
6,gey y
LEGAL DESCRIPTION:Z 2• 6/ •///e k'ut"ey ' '
cif / C
it
2
2i
3
4
5
6
7
8
9
10
11
12
13
1
4
15
16
17
18
19
20
DEPTH
1FFF Ta
SwL
it/
rr1
•�i% •ala Fao�`
*I F1, : i. :'r:"� 2 �s 8�
• •. i'ys•e• e7yr. /'oaewd•• ` 4
aagayH•N••••• a• ••• •P
a
David R. Payton
Sa� NO. 2t6.13 -E ,CP'
s e-17
DATE PERFORMED: x? -
Township, Range, Section: Sac - 41`j' ) 5N,
SLOPE SITE PLAN
1
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
S
L
0
P
E
Depth to Water AfterA/0.4J $�� /9,7/Monitoring? 11O Dat • 412-7/91,
N
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
Pr2GSD
i
447.i4 #
1 e-. -2 3- 3 y
3c)
77 _ /05i
Z ra
Z.
Z3_ -3 os
30
71. — / >'
1 ZJ8
3
X0&-33.1.
30
7%a-/0o/r
ZN
4-
3a1 - Vo?
30
7%- /D"
Z%
PERCOLATION RATE
(minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN' FT AND CO FT
COMMENTS • ' '' _
PERFORMED BY: 'Q
Pa
CERTIFY THAT -THIS TEST WASPERFQRMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE
72-008 (Rev. 4/85)
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
77/
PERFORMED FOR:
LEGAL DESCRIPTION: LZ i ✓i 1I4410t-Cy LI?gtt.)
G`3T,
,y -
DEPTH pL6A.-»t
(FEFT)
Si cry
S.ti•.+O
5 -
10
11 -
12-
13-
14
LTV G-/1.f'vcr-r--
Ln
i3 C.- -tt)vvl. o {Z
15-
16-
17-
18-
19-
20 -
*r 49T
e•,0•Po••••I ••••oe• •••. •sa�S'k
MC David R. Dayton /t{tu!
1 r9
p Fn r
DATE PERFORMED IN`trr./..g':
Township, Range, Section: z>c 4-. -1--IS J
SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
S
L
0
P
E
Depth to Water Atter �2 5� jg
Monitoring? '4'6 Date:/27th
21W
N
S�-
054
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
el /
/
a°" 2- .-5-.2
'°
74 - //A'
371-
7-2
2.
L31�3 cz
303 _373
3m
4 v
ii -- //%z
7J -//YP
___1X7
31'2
3
4-
33S -V°
3o
Jit `//Xy
37x._
PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN'
FTAND
7` FT
COMMENTS
PERFORMED BY: a wo "pYJ
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
72-008 (Rev. 4/85) - -
CERTIFY THAT THISTEST WAS PERFORMED IN
DATE Sr ://4.‘ fi
D. R. DAYTON, P.E., R.L.S.
Chugiak, Alaska 99567 (907) 684)24.4x7
20210 Donalar 696-2417
May 4, 1994
Septic System
Lot 2, Block 1, McKinley View Estates Subdivision
The proposed septic system will serve a 3 bedroom on a lot served
by a Community Water System.
There are no wells within 200 ft. of the system. There will be
no adverse effects on neighboring septic systems, reserved areas or
drainage.
Os
-hue#Arkb d*. nL yf Ofi enmb.4.
.K.: ,ovi6i It. on
NO. 2s20 5 -E ,•' _
4.4 .6
' '.,APE`•••• y
pFOFES41�'�