Loading...
HomeMy WebLinkAboutMCMAHON BLK 2 LT 16 GREA,CR ANCHORAGE AREA BOR . Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE FROM WELL Li INSIDE LENGTH MANUFACTURER _,,~:¢..z~LA~ ~ MATERIAL INSIDE WIDTH LIQUID DEPTH NUMBER OF COMPARTMENTS_ LIQUID CAPACITY /~O GALLONS. TILE DRAIN FIELD:r'~~ DISTANCE FROM WELL FOUNDATION NEAREST LOT LINE TOTAL LENGTH OF LINES NUMBER OF LINES DISTANCE BETWEEN LINES TRENCH WIDTH__ IN. TOTAL EFFECTIVE ABSORPTION AREA '-~ "'~¢--?~ SQ. FT. LENGTH OF EACH LINE DEPTH OF FILTER (~ (¢~ (" DEPTH: TOP OF TILE TO FINISH GRADE "~ MATERIAL BENEATH TILE__ IN. ABOVE TILE IN. WELL: TYPE _ BUILDING FOUNDATION CESSPOOL APPROVED CONSTRUCTION DEPTH NEAREST NEAREST SEPTIC SEEPAGE LOT LINE__ SEWER LINE TANK , SYSTEM , OTHER SOURCES DISAPPROVED REMARKS DISTANCE FROM: DISTANCES: DIAGRAM OF SYSTEM INSTALLED BY: SEWER LINE DEPTH: PIPE MATERIAL: LOT SLOPE: REMARKS: f I DATE /~ ¢¢ APPROVED ~ G.A.A.B. Form EQ-032 /LD -',-/- ?£. t-ll_l~& ICI F'RLI ]-'~-' IDF Rr~CHORRGE DEPRRTMENT OF HERLTH RND ENVIRONMENTRL PROTECTION ~0 C STREET, 8NCHORRGE~ 8LRSK8 9~50~ 274-456t PERMIT NO.( JERRY DELCR~JJ~ PO BOX 192~ ~44~8 LOCBTION FURROW CRK RD LEGRL L i~ B 2 MCMBHON SD LOT SIZE 320~8 SQFT TYPE OF SOIL RBSORPTION SYSTEM...TRENCH NUMBER OF BEDROOMS 5 SOIL RBTING~SQFT?BR i50 THE REQUIRED SIZE OF THE SOIL BBSORPTION SYSTEM IS:DEPTH= i5 LENGTH= THE MINIMUM DEPTH OF GRBVEL BETWEEN THE OLITFRLL PIPE BND THE EXCBVBTION BOTTOM IS B FT THERE IS NO SET WIDTH FOR TRENCHES. FOR DRHINFIELDS, THE WIDTH IS ~ FT. THE DEPTH OF TRENCH OR PIT IS THE DISTBNCE BETWEEN THE GROUND SURFBCE BND THE BOTTOM OF THE EXCBVBTION. THE LENGTH DIMENSION IS THE LENGTH OF EBCH SIDE FOR B SEEPHGE PIT OR THE LENGTH OF THE TRENCH, OR DRBINFIEL. D. THE REQUIRED SEPTIC TBNK SIZE IS i500 GBLLONS 8BCKFILLING OF BNY SYSTEM WITHOUT ~I~'~E' INSPECTION BY THIS DEPBRTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTBNCE FROM WELL TO BNY SEPTIC TBNK?PBCKBGE PLBNT OR SOIL BBSORPTION SYSTEM IS t00 FT FOR B PRIVBTE HELL BND 200 FT FOR B PUBLIC HELL. WELL LOGS MUST ~E RETURNED TO THE DEPBRTMENT WITHIN 50 D8YS OF THE WELL COMPLETION. SPECIFICBTIONS BND CONSTRUCTION DIBGRBMS BRE 8VBILBBLE TO INSURE PROPER INSTBLLBTION. I CERTIFY THBT I BM FBMILIBR WITH THE REQUIREMENTS FOR ON-SITE =,EWER_ BND WELLS RS SET FORTH BY THE MUNICIPBLITY OF 8NCHORBGE BN[:, WILL INSTBLL IN BCCORDBNCE WITH THE CODE. , ........ CONSULTANTS, INC. 2,49 EAST SIST AVENUE P.O. BOX 6087 ANCHORAGE. ALASKA 99503 ' TELEPHONE 907-279-0483 October 21, 1975 R & M NO. 562144 R Jerry Delcamp P. O. Box 1923 Anchorage Alaska 99510 P~E: Test Hole and Soil Log Report for Sanitary System Lot 16, Block 2, McMahon Subdivision Dear Mr. De!camp: We are submitting herewith the test boring results and our co~ents regard- ing soil conditions encountered at the subject site. This investigation was performed in accordance with your request of 10-20-75 and those proce- dures outlined in a letter dated July 15, 1975, by Mr. Rolf Strickland of the Greater Anchorage Area Borough Department of Environmental Quality. A single test hole was put down within the Lot 16 area for'the purpose of defining general subsurface soil conditions for the proposed sanitary system. Excavation was accomplished with an auger type drilling rig and the origi- nal test hole was extended to a total depth of 20,0 feet below ground sur- face. The final log prepared for the test hole has been included in Drawing A-01. Ground water was not encountered in the test hole. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M CONSULTANTS, INC. Vice President JWR/WED/j a xc: GAAB ~ TH-1 TH-1 10-20-75 ORGA/'~ICS 0.0~ ORGANIC SILT SO~gg SAaND (}iL) 2.0' GRAVELLY S~D w/TRACE COBBLES (S?) 4.57 SANDY GRAVEL TRACE SILT (GW) 5.5' SILTY SANDS TRACE GRAVEL (SM) '7.0' SAND TRACE SILT TRACE GRAVEL (S~) 17,0' SAND TI{ACE SILT SOME GRAVEL (S~) NO WATER T~LBLE 20.0' T.D. Log represents location of test hole, Lot 16, Block 2, McMahon Subdivision, NE 1/4, h~E 1/4, Section 28, T12N, R3W, S.M. R Consultants lac.  ANCHORAGE FAIRI~ANXS ALASKA JUNEAU JERRY DELCAF[P PROPERTY Log of Test Hole Anchorage, Alaska SCALE 1"=3' OWN SY WED c~)<o s¥ ['{ED NO. 562144 OWO ~O.A_01 WATER WELL LOG WELL oWNER FOSS DRILLING 1336 Ingra Street Anchorage, Alaska 99501 USE oF WELL SIZE OF CA~ING~ ~,,DEPTH OF STATIC WATER LEVEL FEET OF DRAWDOWN. FT · RF~S DATE COMPLETED PUMP TO BE SET AT /~_to ~' , to to to __to ,,to , ,to.__ to , GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 ~ ~S,Q~ . Date Received January 12, 1977 ,.~¼~ 'a ,~. ~0~ Time of Inspection £/'~ Pr~l ~g~~~ Date of Inspection /-~-7~ ~Y3.' ~ ~ ~ INDIVIDUAL SEWER & WATER FACILITIES l. gppr0va] requested by: ~at~onal Bank of ~laska Mailing Address: Post Qffice. Box 3-3859 99509 Phone: 279-2506 2. Property Owner: G~rald C Delcamp Phone: 272-9507 Mailing Address: 3737 West 87th Avenue 3. Legal Description: Lot 16 Block 2 Mc Mahon Subdivision 4. Location: 5. Type of facility to be inspected Single Family No. of bedrooms l~ -)~[ 6, Well Data: A. T~pe Individual C. Construction /x~~_ Sewage Disposal Sy~em: On-site system A. Installed C. Septic Tank: B. Depth D. Bacterial Analysis IQU~o B. Installer 1. Size ;,SLD~D. 2. Manufacturer ~,~ D. Seepage Pit: l. Absorption Area ~5/~q~).' 2. Material E. Disposal Field: Total length of lines 8. Distances: A. Well to: Septic tank , Absorption area , Sewer Lines , Nearest lot line , Other contamination B. Foundation to septic tank , Absorption area C. Absorption area to nearest lot line EQ-034 (1/74) Page 1 of two pages Page '2 of two pages - Re(~'st for Approval of Individual .¥~'~r & Water Facilities ~egal Description Lot 16 Block 2 Mc Mahon Subdivision Comments Approved Disapproved Date~ .... App~al\Va!id for one year from date signed ~, Greater Anchorage Ar~a Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74) MUNICJPALITY OF ANCHORAGE DEPARTIV]ENT OF ENV!t:~ONMENTAL QUALITY 2518 Tudor ]load .Anchorage~ Alaska 99503 REGUEST FOI':{ APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES RECEIVED,' t. Type of Inspection: CMRO 2. :Property Owner: JVlaiiJng Address: _t~ ~/,~ ~ /~-.), 3. Name of Buyer: VA. FHA CONV /~ ' [\~,ailing .Address: 4. Name of Lending Institution: Mailing Address: 5. Name of Realtor or Agent: Day Phone ,Mailing Address: Phone Legal Description:~L'~ //~ ~ c~ 8. Water Supply Type of Supply: Public Utility :if Individual, number of dwellings presently served If Individual, depth of well 9. Sewage Disposal System Type of System: Public Utility ~No. Bdrms. Individual ,X .... Individual (on-site) tf Individual, date of installation EQ-037 (i/74) 06-1220(a) Rev. 1973 DATE ALAS .... DEPARTMENT OF HEALTH AND SOCIAL : DIVISION OF:PUBLIC HEALTH INDIVIDUAL AND SEMI*PUBLIC BACTERIOLOGICAL WATER ANALYSIS ]NblVlDUAL-Iq SEMI-PUBLIC [] CHLORINE RESIDUAL PPM REPORT RESULTS TO ADDRE~SS. /' - :.~ ~_, :.: Lab No. OFFICE ?-' .:- ~'-~-' ~ [] Bottle broken in transit, ple~e-' s~nd' n~~ s~mple. CITY · ~ ":' '¥ ' ' '"" '-~-- ZIP CODE ..... ~ _~ OFADDRESS SOURCE .: ":--" "'"' "-;"' =~'/?!'~ :: -' /~/ ~';~..,' '', .... '.' 'S ,.-_ . · ....,....;: ,~ . .?__.--~ > · . ::.; ..... COMPLETE THIS S[CTION- /An~Jysls shows thTs Wc~ter SAMPLE to be: ~"~Safisfactory [] Unsatisfactory ' - ' :. . [- Sample too long in transit; saml~let ~'l~0ul~l not be over 48 hours old at examination to indicate reliable results. Please ONLY IF WATER~ I$ AN INDIVIDUAL SUPPLY ~' - / . . .::.? .:; · Well-- [~ Dug [] Driven [] Drilled [] Bored SOURCE: [] Spring [] Cistern [] Other' Dug Well or Cistern Construction: Walls-- [] Wood [] Concrete [] Metal [] Tile Brick or Top -- ~- Wood [] Concrete [] Metal [] Open Top [] Concrete LOCATION: [] In Basement [] Basement Offset [] Under House []In Yard [] Other Building Sewer Septic DISTANCE TO: or Other Drainage Pipe Feet. Tank Feet Tile Seepage Cess- Field Feet. Pit Feet, Pool Feet. Privy__Feel. Other Possible Sources of Contamination ", MATERIAL: Building Sewer- [] Cast Iron [] Wood [] Tile [] Fibre [] Asbestos Cement [] Plastic Joint Mater~al - Type GENERAL: Does Water Become Muddy or Discolored? [] Yes [] No When? D~ameter of Well Well Casing Material Diameter Length of Drop P;pe Offset in PUMP LOCATION: [] In Well [] Basement On Top [] Of Wel [] Other PURPOSE OF EXAMINATION: Illness Suspected? New Source of Supply? [] Yes Depth Feet· Depth Water Depth From Bottom - Feet. [] In Basement ~ Room READ INSTRUCTIONS ON REVERSE SIDE BEFORE COLLECTING SAMPLE [] Yes ~ No 'i ..~ ~ , ~ . [] No Repairs to System? [] Yes r~ No Signature . - 06-i~2o (bi BA~TERIOLOGI(~AL WATER ANALYSIS RECORD Rev. 1973 Date Received ~ ~ _/~ /~ [ -~) -'~ Time Received ~.z,_ pm ,~ab. No Lactose Broth 1gcc 10cc 10cc 10cc 10cc 1.0cc 1.0cc · 24 Hours Brilliant Green 24'Hours 48 Hours ' EMB AGAR Lactose Broth, 24 hrs. 48 hrs. Gram's stain Coliform Density (Most probable No. per 100cc) MF Results Reported by This analysis indicates Coliform Organisms to be: