Loading...
HomeMy WebLinkAboutMCMAHON BLK 3 LT 17 GREA ,"R ANCHORAGE AREA BOR':"qGH Q Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME ",~"',,~g~'~ v~'~-'~'~--~ DISTANCE ~.~ / FROM WELL MANUFACTURER INSIDE WIDTH INSIDE LENGTH MATERIAL LIQUID DEPTH NUMBER OF ~--.~--~x.-~---~.. COMPARTMENTS LIQUID CAPACITY /--~//g/~' GALLONS. SEEPAGE PIT: NUMBER OF PITS LINING MATERIAL BUILDING FOUNDATION__ ADDITIONAL ABSORPTION DIAMETER /'~ %R WIDTH ~, LENGTH ~ DEPTH CRIB SIZE: DIAMETER ~> DEPTH ~' DISTANCE FROM: WELL NEAREST LOT LINE ~:2 ~.~, TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) /_~b' ~- SQ. FT. WELL: T Y P E CONSTRUCTION ~-~/~ DEPTH DISTANCE FROM: BUILDING FOUNDATION NEAREST NEAREST SEPTIC ~-- / SEEPAGE LOT LINE /~ [/ SEWER LINE /~ ~'~ TANK ~ ~ SYSTEM CESSPOOL /f'/'~/'"/~-~' , OTHER SOU RCES APPROVED LOT SLOPE: R E M A R KS: Form No. EQ-031 DIAGRAM OF SYSTEM GREATer ANCHOrage Area Borough DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 PERMIT SEWAGE DISPOSAL SYSTEM M APPLICATION AND PERMIT MAILING ADDRESS PH ON E~/~/-~ ~--Y~ · DRAIN FIELD . , OTHER LEGAL DESCRIPTION ~) ~ INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH SOIL TEST RESULTS /~ COMPLETION DATE ANTICIPATED SEEPAGE PIT TO BE INSTALLED BY '~ '/~/~/ NOTE: THIS PERMIT iS NOT VALID WITHOUT SOIL TES~ FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE TYPE MINIMUM DISTANCES, REQUIREMENTS SEEPAGE AREA SIZE //~ /¢/X ~/~//~TYPE DIAGRAM OF SYSTEM FOUNDATION TO SEPTIC TANK / / FOUNDATION TO SEEPAGE PIT . DRAIN FIELD / SEPTIC TANk TO SEEPAGE PIT WAL[ 5'-~ ~c SEPTIC TANK , SEEPAGE PIT ., DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK ~ ~) . SEEPAGE PIT ! DRAIN FIELD /~ ~ WATER MAIN TO SEPTIC TANK DRAIN FIELD SEPTIC TANK, , SEEPAGE PIT TO RIVER. LAKE. STREAM. ALSO CONSIDER AREA WELLS. SEEPAGE PiT /~/ , DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET into UNDISTURBED SO[L. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING ~NSTALLATION. OR LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUireMENTS OF GREATER ANCHORAGE AREA/~R(~UGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE With SAID CODE. /~ ~ // APPL'CANT'B--NAT RE GAAB-HD- I ,ER ANCHORAGE AREA BOR: '~ DEPARTMENT OF ENVIRONMENTAL 0. UALIT~' 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE FROM WELL LIQUID CAPACITY /~9 ~)~ GALLONS. MAILING ,/'~'~,'~ ~ ~'J-"~'/t ADDRESS~'~'~'.g/, ~O~'~' ~ ') ~/ PHONE NUMBER OF / MATERIAL ~'"/':~t: z;':,Z, COMPARTMENTS O~.¢,~.~Wt~ .,~¢-',~'1,.) ~' /~ ~I~IL~//,"I I~=/,Z'' ~'~/CtL:~ LIQUID INSIDE LENGTH. INSIDE WIDTH DEPTH SEEPAGE SYSTEM: NUMBER OF PITS LINING MATERIAL NEAREST LOT LINE SEEPAGE PiT: ~ OR WIDTH. LENGTH /DEPTH TILE DRAIN FIELD: DISTANCE FROM WELL L"JL.:r~/'~¢'~! ~'"~- ' , FOUNDATION NUMBER OF LINES DISTANCE BETWEEN LINES ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE DEPTH: TOP OF TILE TO FINISH GRADE ,NEAREST LOT LINE ~ TRENCH WIDTH TOTAL LENGTH OF LINES IN. TOTAL EFFECTIVE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE__ WELL: TYPE//~/O,V/ DEPTH //,?9 LOT LINE 6t~/~/~//~/~TLj~, NEAREST .-- SEPTIC SEWER LINE ., TANK DISTANCE FROM x · BUILDING FOUNDATION. ~' "'-' , SYSTEM_ eL) ~ /' SEEPAGE WATER SAMPLE,/~.~''1//9,''~'~ , NEAREST OTHER , CESSPOOL SOURCES DISTANCES: DIAGRAM OF SYSTEM Sop%ember 13, 1969 ~. James Posey P. O. Box 8361 Anohorage~ 99 o4 Percolation Test Lot 17, Block 3 of the MeMmhon Subdivision Dear Nr. Posey~ This letter is to certify that a percolation test has been conducted on the ~bove~mentioned property. It w~s determined at the time of our investigation that a percolation test was neoemmary and the information enclosed here-in describes the soil characteristics ~d percotmtion rate fo~ you~. property which is adequmte for ~ sewer system~ Location of the septic %~k and seepage pit is shown on %he at%ached Greater Anchorage ~re~ Borough Health Department form. This tezt wa~ performed in accordance with the Greater ~nohorageArea Borough Health Department specifications and, the Public t~al%h Service Publication No. 5~6o Respectfully submitted, W~ll~m~ ~,. ~.kmoa-u Nana~ger P;nolosure Greater Anchore~ge Area Borough Health Department GREATER ANCHORAGE .AREA BOROU HEALTH DEPARTMENT ' $27 EAGLE STREET ANCHORAGE, ALASKA 99501 Performed For_ ' . ~al Descri tzon: ock ~ S~dzv~szon This Form Reports a: Solls Log~ ~ ...... '~{_~--. 0 0.5 2 4 Depth Feet Soil Characteristics Overburden Was Ground Water Encountered?__~9__.~ if Yes, A~ What Depth . Reading Date Z:35 '" , Z:40 Location Sketch · 5 ainu%eS i · e 1 /~~fihu~ ..... Proposed Installation: Seepage Pit X Drain Field X Depth Of Inlet Deptb.~ BOttom Of'~it Or Trenc.~~ COMMENTS: Test Performed B~: Data Certified By: ~'~illiam E. Dun a. Date: o ~ -- -~' '-- AFril 29, 1970 ,~sox g3Ol Anchora~.;e, Alaska 99504 Lot 17, Block Su~i sion A review oF thi.~ i~part.~ont . records has revealed a percolation test ~or the subject lot. ~ .. ~ this F~pa~ment of your plans regardin~ the installa- leas~ ac~ise tion of a sewer systea on this pro]~rty, ~ you could co,~ into our office at ~27 [~agle Streot, we could then revim~ your plans and issue you the required permit for a sewer syste~ i-nstallatic,~. Sincerely, CLIFF(~RD P. JU[)K!N~;~ Adainistrativo Dim~ctor s..~.,PT FOr CERTIFIED POSTMARK OR DATE CITY, STATE. AND ZIP CODE -- EXTRA SERVICES FOR ADDITIONAl, delivered delivered 10¢ fee [] 35¢ fee POOForm~SOQ NO ,NsURANC£ COVERAGE Nov. 19~ NOT FOR iNTERNATIONA See other side) FEES Deliver to Addressee Only GREATI=R ANCHORAGE: AREA BOROUGH HEALTH DEPARTMENT 327 EAGLE STREET · P. O. BOX 968 ANCHORAGE, ALASKA 995OI PHONE 279-25! I January 18, 1971 Mr. James Posey Box 8561 Anchorage, Alaska 99504 SUBJECT: Sewer System for Lot 17, Block 3, McMahon Subdivision Dear Mr. Posey: April 29, 1970, we wrote you regarding a percolation test on the subject lot. To date we have not received a reply to that letter. -'- Please advise this Department of your plans regarding the installation of a sewer system on this property. Sincerely, Lynn S. toad " Sanitarian AIR MAIL TO ALASKA IS FASTER January 18, 1971 Mr. James Posey Box 8561 ^nchorage, Alaska 99504 SUBJECT: Se~qer System for Lot 17, Block 5, McMahon Subdivision Dear ~Ir. Posey: April 29, 1970, we ~qrote you regarding a percolation test on the subject lot. To date ~ve have not received a reply to that letter. Please advise this Department of your plans regarding the installation of a sewer syste~ on this property. Sincerely, Lynn S. Coad Sanitarian ~n