MCMAHON BLK 4 LT 1
McMahon Block 4 Lot 1 #017-041-10 i MUNICIPALITY OF ANCHORAGE DE (TMENT OF HEALTH AND HUMAN SER\ ES Environmental Health Division 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Name y L, Cv 6V=dy91 DISTANCES FROM TO SEPTIC TANK ABSORPTION FIELD WELL Address l/? y 5, "!3 WELL P 9 7- //_s) Phone y r0Z7,1 Permit No. ed oo/061(;,.3 No. of Bedrooms LOT LINE N �d ` XS LEGAL DESCRIPTION Lot Block Subdivision Ne �uy� FOUNDATION NO% /� i✓o{ /A% Township, Range, Sectionn ,5" 2 r/L rJ n 3 o AS -BUILT DIAGRAM (Show location of well, septic system, property lines, foundation, driveway, water bodies, etc.) TANKS HuFn1 u - go r> tit ITLI POLC � to CY,SEPTIC ❑ HOLDING Manufacturer p / Capacity in gallons x1 kit 1- S yn rit1, Material No. of Compartments TYPE OF SYSTEM w t Clicort 17 TRENCH El/ BED S. DRAIN (3f)❑ OTHER Depth to pipe bottom from Total depth from original grade original grade / FT 7 FT Fill added -above original grade FT Gravel depth beneath pipe 3 FT Gravel length 6q FT Gravel width Cl1 3� a ^"''FT Total absorption area 3919 SO FT Distance between lines FT 3 tiv 1� Number of lines 3 Soil rating JZ S SOFT1 Pipe material 11>3034 C1 Installer S*w ShrecK Date Installed 6-13 :%-4--)6 lk$G Cl WELLS w�l PRIVATE ❑ OTHER fldentifv) Classification (A,B,C) Total Depth FT Cased to FT Installei Date Installed: REMARKS: /S'f 1'45?cx 'unr ) 7�� 2hd i4S�cfion Dar- Scale: / 2 LIFO /,,"It7 IV Inspections Performed by. /? Fr -S $5 0 ENGINEER'S SEAL Date: July inspection was performed according to all ,P certify that this Municipal and State guid Ines in ellecl on this date: J u !X / / I Health Department Approval: "y\�� Date 7 7 f4 72-013 (3/85) ** TANK MUST HAVE AT LEAST TWO COMPARTMENTS ' I certi�y that; 1" I yor on~site sewers and wells as set forth by the Municipality of Anchprage (MOA) and the State of Almka" 2, I will install the system in accordance with all MOA codes and regulations, and in complwith the design criteria of this permit. ^ 3. I will adhere to all MOA and State of Alaska the set back distances from any existing well, wastewater disposal system or public sewerage system on this or any adjacent or nearby lot. ` 4. I understand that this permit is valid For a maximum of 3 bedrooms and _ any an additional permit" � IF,A LI|T STATION %S INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THEN (1) AN ELECTRICAL PERMITAND INSPECTION MUST BE OBTAINED; (2) AS'BUILTS CT ON REPORT AND (3) THE WILL NOT BE APPROVED WITHOUT AN INSPE I ELEC�RICAL � ELECTRICAL WORK MUST BE DONE BY A LICENSED ELECTRICIAN. SIGNED ~- DATE: _ -______._ =- APPLICANT: BETTY ��VANS ISSUED BY/1_ ��«�~�,�� DATE: _~..�L�..~~_~..._��~--.__� �--��~� ^ '.. ��_111[ C.�:: 1: 10" env I.... I -'Ir " --V C-34 ��Ff. E_..� ' DEPARTMENT OF HEALTH AND ENVIRO|MENTAL PROTECTION 825 L STREET, ANCHORAGE, AK 99501 , 264~4720 �4 TE'E' ��Vr";� 0 B ][ q- PERMIT NO: 860016 ��\� �° DATE ISSUED: 01/17/86 'nou*a� A|�`P|�.ICANT�: BETTYEVANS ����^ ^�y��~� /�~���� . _e;»'-I � ^-- ~ ADDRESS: 11240 S. BRA(DjAW ANCHORAGE, AK 99516 . CONTACT PHONE: 349�1029 ` LEGAL DESCRIP: SUBDIVISION: MCMAHON LOT: 1 BLOCK-4 SECTION: 28 TOWNSHIP: 12N RANGE: 3W LOT 556 (SQ"FT. OR ACRES) MAX BEDROOMS: 3 , / Listed below are the to you in designing your E.ieptic system. Choose the option that best fits your site" ������H-A ER E'EAD k.4 ��F..-!;: ii�nv 1: 11N.11 DEPTHTO PIPE DOTTOM(FT") 6.0 ' ` 6^5 6^0 GRAVEL DEPTH (FT") 3^0^ 0"5 2"0 TOTAL DEPTH (FT" 9~0 7°0 8.0 GRAVEL WIDTH (FT.) 2"5 14., 5"0 GRAVEL LENGTH (FT,) 43"(::) 28.0 36"U GRAVEL VOLUME (CU^YDS.) 14,0 14"6 16.7 TANK SIZE (GALS) 1,600.0 ** 1,000^0 ** 1000.0 ** SOIL RATING (SQ"FT�/BR) 85 85 85 ** TANK MUST HAVE AT LEAST TWO COMPARTMENTS ' I certi�y that; 1" I yor on~site sewers and wells as set forth by the Municipality of Anchprage (MOA) and the State of Almka" 2, I will install the system in accordance with all MOA codes and regulations, and in complwith the design criteria of this permit. ^ 3. I will adhere to all MOA and State of Alaska the set back distances from any existing well, wastewater disposal system or public sewerage system on this or any adjacent or nearby lot. ` 4. I understand that this permit is valid For a maximum of 3 bedrooms and _ any an additional permit" � IF,A LI|T STATION %S INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THEN (1) AN ELECTRICAL PERMITAND INSPECTION MUST BE OBTAINED; (2) AS'BUILTS CT ON REPORT AND (3) THE WILL NOT BE APPROVED WITHOUT AN INSPE I ELEC�RICAL � ELECTRICAL WORK MUST BE DONE BY A LICENSED ELECTRICIAN. SIGNED ~- DATE: _ -______._ =- APPLICANT: BETTY ��VANS ISSUED BY/1_ ��«�~�,�� DATE: _~..�L�..~~_~..._��~--.__� �--��~� �U phi :1��VON M I_ 11 1"Y" POO- F-11 1117-14 F-111 IC:)���� DEPHRTMENT,�F`HEHLTH HND ENVIRONMENTHL��/OTECTION �� /~�^~ A. 6 E 25UDOR RD/ HNCHORHGE/ HK��7 ' *� � 276'2221 ��RiD, ����JE , P� �ERMIT NO ( 77062 ) ' HPPLICHNT 612 1/2 EHST 1440 HYE 272~6]05 LOCHTION LESLIE ST LEGHL L.A. B4 MCMHHON SUBD LOT SIZE ]]55� SQUHRE FEET TYPE OF SOIL FHB SORBTION SYSTEM ISn TRENCH MHXIMUM NUMBER OF E)EDROOMS 4 SOIL RHTING (SQ FT/BR)� 85 YS vD. BEE FO" -Y 1-4 HE TRENCH OR DRHINFIELD. THE DEPTH OF H TRENCH OR PIT IS THE DISTH EEN THE SUFIT" HCE OF THE GROUND HND THE BOTTOM OF THE EXCHVHTION (I ) THE ETWEEN THE OUTFHLL PIPE HND THE BOTTOM OF THE EXCHVHTION (IN 171 FEE CIA L A X IFT? us: TJ TEL FEE 0:04 _T_ 70: 10 W low RUA K PEE to. 22 oil Uzi His low �L. fit Phs SR. W 11,41 cin NC Q! Do 3: 1`41 T; 1=4 K 02 -Y K: Hot PEE K0, BHCKFILLING OF HNY SOYSMEM 1411151. HPPROVHL BY THIS DEPHRTMENT WILL BE SUM ' TO PR - MINlMUM DISTHNCE BETWEEN H W SITE SEWHGE DISPOSHL SYSTEM IS 100 FEET FOR H PRIVHTE WELL O F H PUBLIC WELL WELL LOGS FART REQ RED HND MUS RNE TO THE DEPHRTMENT WITHIN ]0 DHYS OF THE WELL COM ION SPECIFICHTIONS HN CONSTRUCTION HG S HR HVHILHBLE TO INSURE PROPER INSTHLLHTION� \ \ \ � �������,, P 3EV 1: I HW! FHWIILIHR IREME S FOR GN~SITE SEWERS HND WELLS HS SET FORTH BY THE MUNICIP NCHOR E 2� I WILL L INSTH�N HCC DHNCE WITH THE CODES I� I UNDERSTHND T TE SE 1, 1 R SYSTEM MAY REQUIRE ENLHRGEMENT IF THE RESIDENCE IS REMO UDE M 0 E THHN 4 BEDROOMS. SIGNED ~. ~� HPPLIWIN T BOB G[��TZEL / ALASKA ENVIRONPAENTAL ADB RP y Cvaar # "O CONTROL SERVICE INC. SHEET NO. OF 1200 West 33rd Avenue Suite B ANCHORAGE, ALASKA I4kA;§_jALITY OF ANCHORAGSCULATED BY le DATE i—lD-SCS Phone 561-5040 DEPT. OF HEALTH & ENVIRONMENTAL PROTECTICSIGECKED BY DATE_ SCALE l - logo W#al 4f'__ Y d's pr,j'Y,1-'rces�1rc G,�m Maxi ow) ALASKA ENVIRONMENTAL CONTROL SERVIC^, INC. 1200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 561-5040 JOB Me h1ul�o., L SHEET NO. OF CALCULATED BY ��'� "7 DATE CHECKED BY SCALE I DATE Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST (ENGIN AL), PERFORMED FOR: Steve SQiltrwe n,. t•frDATE PERFORMED: +%`/3-- 86 LEGAL DESCRIPTION: fort 1 5)OL�- 4 •-6�4c) Township, Range, Section: Se. Zg' 'rttlV P_31.J- » SLOPE SITE PLAN 1 rel oyv"s c 31 H I C,►�t Sol 5ajjj jrove( ,vZ cfood '-ft„") Sah" Iewa--- 4 5 6 ,A : a P sandy a. t .1 he ucval 7 gravel Lj S��}P 8 - SASk m r ®� day' Vv, ,s rta«a ;n S:1-u,Ff 9 �M N 13 — Depth to Water After Monitoring? Date: 14 15 16 17 18 19 ■■■■■®I■IMM■ ■■■■■■1■IIl 10 !MMS'■ER■L WAS GROUND WATER QQ T ENCOUNTERED? tJ 1) 1 1 a4 0 � p i IF YES, AT WHAT 0 12 U- f� DEPTH? P v� g � E �M N 13 — Depth to Water After Monitoring? Date: 14 15 16 17 18 19 ■■■■■®I■IMM■ ■■■■■■1■IIl . E !MMS'■ER■L EM 2 u/o ad! Date Gross Net Depth to Net Time Time Water Drop 20 I PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER lul /TEST RUN BETWEEN FT AND FT COMMENTS s6,-/ fYUMy 76 /`S re -r -.*e( 10 /45— ! P PERFORMED BY: __A r: c -f ��`� Wf •�� I - nTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 7-zr-9-e 72-008 (Rev. 4/85) RSM CONSULTANTS, INC EA GAN [ERS GEOLO .I `iT5 PLANNERS tiURVEYpRS 5024 CORDOVA O BOX 6067 Y ANCHORAGE, ALASKA 99562 A FH. 907'215-J_i: O TEX. 030-25360 February 28, 1977 Mr. Bob Goentzel 612-1/2 East 14th Avenue Anchorage, Alaska 99501 R & M No. 751119 Re: Test Hole and Soil Log Report for Sanitary System, Lot 1, Blocc 4, McMahe Subdivision, Anchorage, Alaska. Dear Mr. Goentzel: We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This in7esti- gation was performed in accordance with your request of February 26, 1977 and those procedures outlined in a letter dated July 15, 1975, by Mr, Rolf Strickland of the Municipality of Anchorage Department of Environmental Quality. A single test hole was put down within the subject site area for the purpose of defining general.subsurface soil conditions for the proposed sanitary system. Excavation was accomplished with a tractor -mounted backhoe and the test hole was extended to a total depth of 13 feet below ground surface. The final log prepared for the test hole has been included in Drawing A-01. Groundwater was not encountered in the test hole while excavating. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M CONSULTANTS, INC. �Q r James W. Rooney Vice President JWR:mh xc: Municipality of Anchorage ..rI .1'1A1( FAIROANKS elvk N O,c oR A�O(Ty Q'eq 1 rF SFr s,9�, c>/0' v�40 WASILLA JUNf. AU VALDEZ " q N HUFFMAN ROAD 30' TH-1 G----- 40' Lot 1, PDlocl: 4, McHann S Note: Test Bole locations are approximate and have not been located by survey methods_ e ek rR �f��.'S.o°0'J �990y a0 0���• ea �a .>,oaoba,vep°p° a��d ' p y JAMES W. ROONEY se.17 CE -1316 ^z TF1 -1 2-28-77 All Samples A 0.0' ORGANIC MATERIAL GRADIIIG TO ORGANIC SILT — — — — — — —1.51 SANDY SILT 7.7/SORE GRAVEL (ML) Brown, Medium Dense This log represents subsurface soil conditions within Lot 1, Block 4, L:e:}cfn Subdivision, Anchorage, Al: C/'lgNo /V VRZ � l :EST HOLE LOG AND F-& EY R&m CONSULTANTS, INC. LOCATION DIAGRAH GR;D 3Fi 34 ..o,..... °.o.o ....... _... FROJ310 751119 2-28-77 ANCHORAGE, ATLASYA .•; 7p z a O e a e ry b 'M1 ff yZ eee a SANDY GRAVEL(j� o W/TRACE SILT (G`.•7) �w boa 64 a 00a O gp Op° ° O OQ O s OD Q °o 13.0' TD This log represents subsurface soil conditions within Lot 1, Block 4, L:e:}cfn Subdivision, Anchorage, Al: C/'lgNo /V VRZ � l :EST HOLE LOG AND F-& EY R&m CONSULTANTS, INC. LOCATION DIAGRAH GR;D 3Fi 34 ..o,..... °.o.o ....... _... FROJ310 751119 2-28-77 ANCHORAGE, ATLASYA 0-1 U phi I CT 1 13"1 L— I —F 17; F" Ff phi NO 1-1 FAR Ff Cis G: ~ ~ ` .DEPHRTMENT HEHLTH HND ENVIRONMENTHL \ >TECTION ~ 825 'L/ STREET, HNCHORHGE/ ^ HK� 995�� 264-4720 PERMIT NOI ( 780297 ) FIT LICHNT SRH BOX 1562~D 274 ]949 1-1)CH1IO04 LESLIE / HUFFMHN LEGHL L1 1.34 MCMHHHN S/D LOT SIZE ]]000 SQUHRE FEET MINIMUM DISTHNCE BETWEEN H WELL HND HNY ON�SITE SEWHGE DlSPOSHL SY�TEM IS 100 FEET FOR H PRIVHTE WELL/ OR 150 TO 200 FEET FROM H PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL WELL LOGS HRE REQUIRED HND MUST BE RETURNED TO THE DEPHRI'M ENT WITHIN ]0 DHYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY HPPLK SPECIFICATIONS AND CON5TRUCTION DIHGRHMS HRE HVHILHBLE TO INSURE PROPER INSTHLLHTION. FE�� I CERTIFY THHT 1 I HM FHMILIHR WITH THE REQUIREMENTS FOR ON-SITE SEWERS HND WELLS HS SET FORTH BY THE MUNICIPHLITY OF HNCHORHGE 2� I WILL INSTHLL THE SYSTEM IN HCCORDHNCE WITH THE CODES if- VI2 ISSUED BY� _` _~—_��~~�^�DHTE�—��._��� ..... ..... ��/_� Wei I Loa,4 �'77-�:: /e�eg � �3 c ...'� -' ✓7 ,�"�t✓a�;� � P if l 'l 4 tr �f.ZV A.a�ibG8�1� � 1 fds �� � ���M' zlt�r` ��� �-`r✓f'Ri,, _ �, � -�.�� ./j G t x 1 lx { S '� �. k 1 e t t- '4��" / t •t x 1 e tkr- ` '' rC-x�`e.4 L t .{ a � � e t ♦ §r � ,{ t 5 � f7 � �sipT-„i 4.. tar -+r- is � y Y x �s r� i trt �+ �: "r .f t <.s ♦ `:xt � y✓' � 3` ,�.v S S +a yk 8i _'�, .G r �.� ,b err' .� M�Y3 .y rnr +�i�� jib � � Y��(i� � :. i gi.o.y.6� �..a �. �.a..,e.mi f3 f � . s.... h✓'.3 ' , . �t .: s�.<lt �-xr., t x=.:' .: r +r , . Fb:. l..rr; r�1 � +:' DELTA DRILLING COM I ',saa Bou 39A Municipality of An orage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 � D 13 (Uc4 Mc &C'Aan Community Class Well ❑ Public Water System Y` !Y J 2 3Y f .' SA Y f K 3111. T CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcell.D.0(7 —c Y( —f0 COSA# 0161359 Expiration Date: {— /1 — D7- Iiwel#iL4c"T MC137 i3L•`1Ci7Zl Complete legal description Lot 1.0 13 (Uc4 Mc &C'Aan Community Class Well ❑ Public Water System Location (site address) _ _ J 2 3Y f 46 er4 rn or SA Current Property owner(s) _ i3e 1±J e I vaA r Day phone `e0 3S/ —GT 70 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address yG0 2 i �Ff Drrw cho.-!! . Ak Day phone Day phone Unless otherwise requested, COSA will be held by DSD for pickup. p tr eat/ Da ,ice ' hit;r4,u:-4cIV wAirm 2. NUMBER OF BEDROOMS: 3 Coto .ready Tai' l+:u. 3S'l— oT7p 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding Tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given In paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of We (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my Investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the Information obtained from the Municipality of Anchorage files and from my investigation and Inspection, the on-site water supply and/or wastewater disposal system Is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Ranecv rl of 919/00, Cev,1- N ew tma/Y,- / •vt er-e«rAr «t -bow Name of Firm _FIuN-,n -fw Phone 3 Hs--r,?s Address t `S -3o ecAv eO•nf Gn Rol/ Anc%c.,-ope 9`u /C Engineer's Printed Name 7_1+ro aeore T-• "c r, a Date G/'7 /ate S. DSD SIGNATURE Jeffo Approved for bedrooms. Disapproved. r., b' it l--•�t t �''••� `i'>..: -. at. rpt =ti •ik1 TAin 0. .:..........ls........ d . T11.00.0RE F. A400RE f �' t�' .;• CE -3539 t;4 Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: Original Certificate Date: 6-11-07. (R".11)05) SCS Ref.X 1072297001 Client Name Flattop Technical Srv. Project NamdR LI D4 McMahon SD Client Sample ID LI 64 McMahon SD Matrix Drinking Water PWSID 0 Sample Remarks: Parameter Results PQL 05/2212007 12:45 ReceivedDate/fime 05/22/2007 14:35 Metals by ICP/MS Stephen C. Ede D Arsenic ND 5.00 Waters Department Total Nitrate/Nitrite•N 0.983 0.100 Microbiology Laboratory Total Coliform 0 All Dstesffimn are Alaska Standard Time Printed Dateffime 06/07/2007 14:09 Collected Datellime 05/2212007 12:45 ReceivedDate/fime 05/22/2007 14:35 Technical Director Stephen C. Ede Allowable Prat Anal)Yis Units Method Container ID Limits Dat: Date Init ug/L EP200.8 C (<10) 05/30/07 04'03107 TK mgfL Sh120 4500NO3•F D (<10) 05/30/07 JDS coVI00mL SN1209222D A (<l) 0522107 DLC Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage. AK 99519-6650 www.muni.orglonsite (907)343-7904 got, e• • Q i - . V �A � i S• (.. I CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 017 —OYl -10. COSA# D' 59 Expiration Date: s' l " 0 CP 1. GENERAL INFORMATION Complete legal description Lo t I- a toe le V. M c hfa %ion S / p Location (site address) 12 Y 3 / L o�� r,ne Sf_ Current Propertyowner(s) Ge -4y Dayphone `lo 3S'l —o7?e Mailing address Lending agency Mailing address Real Estate Agent Mailing Address Nb0 2 TaFf brioa-A� ¢, Ilk yv .Skewa•-F -idle Day phone FS CID Day phone Unless otherwise requested. COSA will be held by DSD for pickup. f l emte- Call D a v..( / t a 4 a F/ -e y 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual On-site Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given In paragraph 4 by an Independent professional civil engineer registered In the State of Alaska. Certificates of Onsite Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system Is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my Investigation and inspection, the on-site water supply and/or wastewater disposal system Is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of Installation. Name of Firm !_ W &,a 1-4cA^, cu/ Sve r Phone Y'/s' —/ 3 s r Address 01S'3o Eckes fame. Rc%, �4.co�� gk gas -/6 Engineer's Printed Name T/14r0de.-e J= . f -re cp.e Date Y .4v wf 2-c406, TN til* 5. DSD SIGNATURE / e�--------------------- - �G Approved for bedrooms. ¢ „? ;TMODCU F. &>09E 3� CE -3589 A- Conditional approval for bedrooms, with the following stipuld�ons •��;,` Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemerttal Engineer's Report Other By: Original Certificate Date:3-9-06 (Rev. 1VOS) Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST i o• • 1• sTT i Legal Description: LO 1- (I gl0cic Y. MC Neriton S/ -D ParcellD: 017-0Y/ AW10 A. WELL DATA Well type —EWIt A, B, or C provide PWSID # = Well Log (YIN) Y Date completed _,/31/75 Sanitary seal (Y/N) )' Total depth 233 ft. Cased to 233 ft. FROM WELL LOG Date of test .5-13 1 /'7 8 Static water level '20Y Well production 1 2 9 - p.m -WATER SAMPLE RESULTS: Coliform O colonies/110 mL Nitrate 1. 14 mg/L Arsenic: 1,.S- ppb date of sample: 7//5/06 B. SEPTICIHOLDING TANK DATA Wires properly protected (Y/N) 'Y*_ i Casing height (above ground) / 6 in. AT INSPECTION 7/20 /aur 20 f ft. N, 6 + g.p.m. Other bacteria 0 colonies/100 mL Collected by: If /a,/•A" T.cA Sc.e I Tank Type/Material gr �t•cDate installed 7 / / /B 6 Tank size 100& gal. Number of Compartments �_ Cleanouts (YIN) Y Foundation cleanout (Y/N) Y Depression over tank (YIN) N High water alarm (YIN) N• 4, Date of pumping 8 / Z /0d' Pumper i C. ABSORPTION FIELD DATA Date installed ZZ±J&r Soil rating (g.p.d./ft' or ft?/bdrm) 125 Mr System type %cmc A tt•.a Length 61 ft. Width 3 ft. Gravel below pipe � i Total depth W. 2 ft. Eff. absorption area 361/ ft? Monitoring tube Y Depression over field N Date of adequacy test 7 / 20 /0 6 Results (Pass/Fail) PoW For bedrooms Fluid depth in absorption field before test 0 in. Water added 1187gal. New depth G in. I Elapsed Time: _0 min. Final fluid depth _QL in. Absorption rate >= Y rO 1 g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date N• A. i D. LIFT STATION N• .4. Date installed 'Pump on' level at_ in. Datum E. SEPARATION DISTANCES Size in gallons 'Pump off" level at Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 1.0d" Absorption field on lot 17-20 Public sewer main ti - A. Sewer /septic service line > 'Lt' Animal containment areas Neat Manhole/Access (Y/N) in. High water alarm level at in. Meets alarm 8 circuit requirements? On adjacent lots > I Ow ' On adjacent lots -� too ' Public sewer manhole/cleanout N• �. Holding tank N• A.. Manurelanimal excrete storage areas N. A. SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 3oProperty line SD' Absorption field is - Water main P.A. Water service line > ro' Surface water > / Oo ' Wells on adjacent lots > 1O4P ' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 30' Building foundation = SO Water main Al. A. Water Service line >10' Surface water 1 IOo ' Driveway, parking/vehicle storage > SG Curtain drain N• Ae Ste•^ Wells on adjacent lots � 101 F. COMMENTS a -.,y,..• .�. C^`� y '•l G. ENGINEER'S CERTIFICATION r 6.� ; TH .' -p ; l� I certify that I have determined through field inspections and"/"�'.�"."�"...... review of Municipal records that the above systems are in OJ,..i"...E.;�.,,,,,f„ conformance with MOA COSA guidelines in effect on this date. a rn;ccc{r, r, UeoR..• 0 r c"" h, -G+ 3589 45' Engineer's Printed Name 7-Aeodo-r- F• l`+oo �c a` r'•�.., �'(�;p. Date 4l_�v..If, ZuO� �•�'_ ;y,. COSA Fee $ H$O Waiver Fee $ Date of Payment 911104 Date of Payment Receipt Number $`I 3 S 2 Receipt Number, (Rev. 11/05) n 36 3Dt 41 T /57S0" p 1� the Bxl%% d .till$9 4MC+ 1 ;io 1, p. . .• 0 H • �¢i 1 V -O A•/ 2 SroRY �Rd ME ! SSE. �,aA'�``�• Q,1� h 2vo FL'R DEQ Zn/W<.'R D. f7�. Fob% /B 7.50' SURVEY CERTIFICATION: I h.,eby c9101y Shot I have ou,v.yed the p,00stly aho..n end do m=gw���y�yj'J},IyJ��7■.�� app e0,lb.d he,.on end that the I,npto W,ne.l. ahv.I.d tha.on ua wlthln the PloOuty Iln.$ end nc o encroKhmente ubl Otho than noted. !."x flOn 4W,54- 4. p. . .• 0 H • �¢i 1 V -O A•/ 2 SroRY �Rd ME ! SSE. �,aA'�``�• Q,1� h 2vo FL'R DEQ Zn/W<.'R D. f7�. Fob% /B 7.50' • r-/17�t,A1orV . S416D. SURVEY CERTIFICATION: I h.,eby c9101y Shot I have ou,v.yed the p,00stly aho..n end do m=gw���y�yj'J},IyJ��7■.�� app e0,lb.d he,.on end that the I,npto W,ne.l. ahv.I.d tha.on ua wlthln the PloOuty Iln.$ end nc encroKhmente ubl Otho than noted. !."x flOn PLEASE NOTE: It is the contract LEGEND: SET ►OSiNO ^O • P� L� �[� INE�ER�S • P ANNERE9 • SURVEYOR6 aloe responsibility 10 cheek top 6/8" REDAII 0 U U of IOYndetlon In fa61101 10 HUD 6 TACK • O w 0.. I.- nEST ESTBENSON BLVD. 272.9231 finish wade and building an' MONVMENT 0 N ORAGE, ALASKA 99503 562.5291 back, tion 10 101 Iln.e AL -CAP G e c^'o' and tI" 9.1 IK NAIL X DESCRIPTION: IRON►IPE o..o ... ELEVS. DATUM ASSUMED .6. �¢n • r-/17�t,A1orV . S416D. SGS ReEN 1063979001 Client Name Flattop Technical Srv. Project Name/N Lot 1 Dik 4 McMahon Client Sample ID Lot I Dik 4 McMahon Matrix Drinking Water All Datts/Fimes are Alaska Standard Time Printed Datt/Time 07282006 9:44 Collected Date/Time 07/182006 13:30 Received Date/Time 07/182006 13:45 Technical Director Stephen C. Ede Sample Remarks: Allowable Rep Analysts Parameter Results PQL Units Method Container ID Limits Date Date [nit Metals by ICP/MS Arsenic ND 5.00 u8/L EP200.8 C (<10) 0720/06 0725/06 NII Waters Department Nitrate -N 1.16 0.100 mg/L EPA 300.0 D (<10) 07/18/06 07/18/06 DSII Microbiology Laboratory Total Coliform 0 coV100mL SM209222D A (<I) 07/18/06 TLF 0 If MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 1. GENERAL INFORMATION lei Application Date /0J (a) Legal Description (include lot, block, subdivision, section, township, range) %/1c 1%Jatior� f3%xA y dot l .Set z8 j/t 1u /Z rt Location. (address �ro[r directions) (b)" Applicant Name :S eve" Sh"« Telephone: Home Business 3y tql S-- Applicant Address 26 � l vary �-,'ve l�ncti AA (c) Applicant is (check -one); Lending Institution ❑ ; Owner/builder,; Buyer ❑ ; Other ❑ (explain); (d) Lending Institution, Telephone Address (e) Real Estate Company and Agent Address Telephone iv (f) Mail the HAA to the following address: 2. TYPE OF RESIDENCE Single -Family 1� Multi -Family ❑ Other Number of Bedrooms 3. WATER SUPPLY Individual Welytid Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. i 4. SEWAGE ISPOSAL Ons itePublic ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 (11/84) k9c /1Iee6wy 6 Y L I 5. ENGINEERING FIRM PROVIDING SPECTIONS, TESTS, FILE SEARCH, DAI 1ND INFORMATION .As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm A Ec S In Telephone J_6 ! s__0 C/o Address /ZC)D 4J 3 J'-� �ilc�ic 141ar%a I f 5-4)_S Date /v /r3 �S Vo ro• ose • ooesq�'!ea• , 0eese• Peeel�fe°OOOB :Bea �P-T___ 4`0 6. DHEP APPROVAL bedrooms b '�� Approved for �3� Y Date Approved- Disapproved Conditional Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025(11/84) 3-D PUMP & WELL M7 HARTZELL STREET ANCHORAGE, ALASKA 99507 907 —344-0732 Date: " �- Contractor:-�— 2rn $ Job Site: 11��--� Legal Description: t -C I MgMahs►Ls 5v T II�E L '3 3d 'D :1 2, Ib -7 1. 2.20 2:25 J. TSA 7Gkli G.} .N,. 2/3'3" 3 213' " 213, „ 2!3'9 ,t ,t I! it Pump Type: 4,�,- gNco 6 Pumping Level: 2-1951 Static Level: Start Time: End Time: tt 12 3avo:M vie rIII's DRAWDNN G.F.M. /!Ott; i AN nlLaS %n2n�$ i^oryl -TDP OP ca5�n n PNGN pt�GE PP�,�'Cf � EPt'�OZEGjvON MONS oE� ON'�N' QR A. WELL DATA MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal Description: Ar A, -6o,' 8 l6 /< y La*/ `e, 2 S- -r,zNR-3(-J Well Classification R"vatP If A, B, C, D.E.C. Approved (Y/N) fJ A Well Log Present &N) Date Completed A 3 6 / q �'? Yield S GP /V ; Total Depth Z 3 _ Cased to 2 3 Y Jkt Depth of Grouting — Static Water Level � /_I ia� Pump Set At Sanitary Seal on Casing LPN) Casing Height Above Ground Electrical Wiring in ConduitON) Depression Around Wellhead (Y/IQ Separation.Distances from Well: -- To Septic/Holding Tank on Lot 3On Adjoining Lots To Nearest Edge of Absorption Field on Lot 2 ; On Adjoining Lots — Gr loo Gr /00 To Nearest Public Sewer Line N To Nearest Public Sewer Cleanout/Manhole 'IA To Nearest Sewer Service Line on Lot 16'7- Zy Water Sample Collected by`f`T /ICc_S ; Date N Z 619-6 Water Sample Test Results Comments -# 1J,// 7r/0" * t 3_s ---6' S 6X 3 2:) PIP "W Wc// B. SEPTIC/HOLDING TANK DATA Date Installed 6-16– 8S Size Standpipes &Q) Depression over Tank (Y/W /600 Air -tight Caps &N) Pumping/Maintenance Contract on File (Y/N) No. of Compartments Mi Foundation Cie Date Last Pumpe /V A for �vA Holding Tank High -Water Alarm (Y/N) Np Temporary Holding Tank Permit (Y/N) Separation Distances from Septi LHo ding Tank: To Water -Supply Well % To Building Foundation To Property Line G8 A- To Disposal Field / b To Water Main/Service Line 4F7_ Z Course G 100 Comments " Page 1 of 2 72-026(11/84) P–A N.4 To Stream, Pond, Lake, or Major Drainage C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata 123- Type of System Design Date Installed 66 Length of Field 6 i Width of Field -3 4- Depth of Field % Gravel Bed Thickness Square Feet of Absorption Area `f l3 Standpipes Present (ON) Depression over Field (Y/6? Date of Last Adequacy Test A Results of Last Adequacy Test N A Separation Distance from Absorption Field: To Water -Supply Well �� Z' To Property Line G To Building Foundation 3 To Existing or Abandoned System on Lot "' A On Adjoining Lots G/- 30 To Water Main/Service Line To Cutbank (if present) `13 To Stream/Pond/Lake/or Major Drainage Course r7 ioo To Driveway, Parking Area, or Vehicle Storage Area 'O�— Comments D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Comments Dimensions Manhole/Access (Y/N) "Pump Off" ,,V>st (Y/N) Pumping Cycles during Adequacy Test. Meets MOA ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed Date Company MOA No. sT� fdz aP@ QFAt%94 Receipt No. (Do t oU,2<J e.kW4 Date of Payment ID -3 . 49JTH� ,tag y d••ee w• •e• •• •eo••e...,� Amount: $ y �9� eal • *eel ,r ee ,e,. • YC. REID, J ; � ��,` • ." c Ar /f -/v T-5 CE - 2251 f� Page 2 of 2 �Jk We![ for ��►�1.�.��`a- ��P•nP �ri</, i.ry c�r,h9 ver,'17'c•-'/1 o.e,.� z-ozshveal _ well - Ina fie5t res(4lf) Municipalicy of Anchorage June 23, 1986 P.O. BuX 196650 ANCHORAGE, ALASKA 99519-6650 (907)264-4111 TONY KNOWLES, MAYOR DEPARTMENT OF HEALTH 8 HUMAN SERVICES Betty Evans 11240 South Bragaw Anchorage, Alaska 99516 Subject: Lot 1 Block 4 Mc Mahon Subdivision On-site Sewer Permit #860016 - Issued January 17, 1986 On May 20, 1986, The Anchorage Assembly approved a new ordinance regulating on-site wastewater disposal systems (septic systems). All septic systems constructed after the effective date of this ordinance are subject to the provisions of this ordinance. Our records show that you currently hold a permit for the installation of a septic system. We strongly urge that you contact this office prior to constructing your system. Any changes in the code that could impact the construction requirements of your septic system will be identified and brought to your attention. Please contact the Environmental Services Division at 264-4720. Thank you for your cooperation. Sincerely, Susan E. Oswalt Program Manager On-site Services SEO/SSM/ljw �l M ®f [. P.Oncherade November 26, 1985 Ms. Betty Evans 11240 S. Bragaw Anchorage, Alaska 99516 Dear Ms. Evans: BOX 6650 ANCHORAGE, ALASKA 99502-0650 (907!264-4111 IONV tiNOWLE ti. I, an v 01+ DEPARTMENT OF HEALTH & HUMAN SERVICES The city is drafting guidelines to tighten requirements for on-site septic systems. Lot 1, Block 4, McMahon Subdivision, is 33,557 sq. ft. in size and appears to have good soils. It is likely that you will be able to have an on-site system on your lot, but I cannot say so for certain until the guidelines are set and the department scru- tinizes an application by you for a permit. Since y, R� ti 0dman Wilson, M.D. Public Health Director Department of Health & Human Services cc: Assemblyman Brockway Assemblyman Evans Senator Sturgulewski Senator Faiks CO-CHAIRMAN FINANCE COMMITTEE 907-465-3740 it nnaft December 9, 1985 Rodman Wilson, M.D. Deputy Director Department of Health and Human Services Municipality of Anchorage Post Office Box 196650 Anchorage, Alaska 99519-6650 Dear Dr. Wilson: JAN FARS POUCH V CAPITOL BUILDING JUNEAU, ALASKA 99811 Betty Evans shared with me a copy of her November 20th letter to you regarding her efforts to construct a home on a lot in McMahon subdivision on the Hillside. As you may recall, the process was proceeding to her satisfaction until she learned from her builder the Municipality was not approving any permits for lots less than 40,000 square feet. For your quick reference, another copy of her correspondence is enclosed. While I certainly understand the Municipal Health Divi- sion's intentions regarding a minimum lot size for on-site septic systems, I would appreciate your reviewing the specifics of Ms. Evans' property to determine if her lot could support an on-site system. If not, your division's expertise in evaluating the alternatives available to her would also be greatly appreciated. in anticipation of Vt ur a SlSt =e, }., a nTr. Y -�u. eas: forward your reply to my Anchorage office (address below). Sincerely, J Faiks nator enclosure cc: Assemblyman Dana Brockway Assemblyman Joe Evans OUT OF SESSION 1024 WEST SIXTH AVENUE, SUITE 302 ANCHORAGE, ALASKA 99501 907-2746611 ity- -\ P.O. BOX 6650 �� �,,a �� icipall ANCHORAGE, ALASKA 99502-0650 j �+ (907) 264-4111 !C nchoY arse TONY KNOWLES. MAYOR DEPARTMENT OF HEALTH 8 HUMAN SERVICES December 23, 1985 Senator Jan Faiks 1024 West 6th Avenue, Suite 102 Anchorage, AK 99501 RE: Lot 1, Block 4, McMahon Subdivision Betty Evans' soils probably would support an on-site disposal system, but she has not yet formally applied for one. I suggested to her at the Huffman -O'Malley Community Council Meeting on December 12, that she do so in order for a record of application be on file at such time as a permanent new rule about minimum lot size for an on-site system was adopted by the Assembly. Currently, the department is not permitting new systems on lots less than 40,000 sq ft, under emergency administration criteria set by Mayor Knowles on October 18, 1985. Whether this will be the administrations'; recommendation to the Assembly may not be decided for several weeks yet. Sincerely, /n(_ . %). Rodman Wilson, M.D. Public Health Director cc: Assemblyman Dana Brockway Assemblyman Joe Evans Betty Evans kec DoE EVANS Assembly Dr. Rod Wilson Health & Human Services 825 "L" Street Anchorage, Alaska 99501 Dear Dr. Wilson: Home: 13116 Bay Circle, Anchorage, Alaska 99515 Work: 1127 West 7th Ave., Anchorage, Alaska 99501 November 27, 1985 Re: Inquiry from Betty Evans, dated 11/20/85 345-3688 (h) 263-7251 (w) Enclosed you will find some materials I received from Betty Evans recently. Would you please advise me on the status of her inquiry. Please direct your response to me and I will see that a copy is forwarded to Ms. Evans. Sincerely, C�L,iLIM� Joe Evans JE/pj Enclosure: as stated cc: Ms. Betty Evans 11240 S. Bragaw Anchorage, Alaska 99516-1521 14 paa� .Saeutiar� %a $autoulranarye �ao�?eHs�! Paid for by Evans for Assembly, P.O. Box 102526, Anchorage, AK 99510 oig�c]22 November 20, 1935 Dr. Rodman Wilson Deputy Director Health & Human Services Municipality of Anchorage P. 0. Box 196650 Anchorage, Ak 99519-6650 Dea B. EVANS 11240 S. BRAGAW ANCHORAGE, AK 99516-1521 MUN�CIpa�fly P ANCH E V nuORA iVMENT O q T� GEN NOV 1©1986 RECEI V ED I bdu�ot 1, Blk 4 McUahan.Subdiui.s�on,--NE%,,__Sec 28, T12N, R3 SNI this spring, 1985 (copy of plat attached). It 13 vacant land with the only improvement a 233 ft. drilled well on which I had a flow test done before purchasing the land. I have applied to the State for water rights for this well. I personally visited various municipal offices and checked the McMahon Subd. covenants and restrictions as to the size and type of house I could build. The previous owner of the land had a perk test done (copy attached). The Hillside Wastewater Management Plan map (copy attached) showed Lot 1, Blk 4 suitable for an on-site septic treatment system. With these assurances that I could build a house on this land, I made the purchase. When I contacted my building contractor recently to review the modest structure I want to build (approximately 1740 sq. ft.), I was informed that the City wasn't granting any building permits for lots less than 40,000 sq. ft.! At no time previous to purchasing this property was I told of this restriction. Drainage, ground saturation and soil composition wer`— e mentioned and I was assured that the lot I contemplated buying would support an on-site septic system. Now 1 face owning a piece of land that 1 can't build my dream house on unless the City will give me a building permit. I have lived in Alaska for 36 years, have witnessed the growth that has besieged Anchorage, am a registered voter who has voted in every election previous to statehood to the present. Since I am an older Alaskan, I want to proceed with building my home this spring 1986 and appeal to you to allow this effort to come to fruition. Please advise, I await your response with high hope of being granted a building permit. 71-6-e 15 i20 ibGL �eS"�fiG� 9 .. % PGIiI� �`c � ��/zd��>r Az/f 4- / I I—ef d Dr. Rodman Wilson Page 2 Very truly yours, Betty Evans 11240 S. Bragaw Anchorage, Ak 99516 Phone: 349=1P1�� 3 y )- . (��-74 Attachments cc: Assemblyman Dana Brockway Assemblyman Joe Evans Senator Arliss Sturgulewski Senator Jan Faiks + 455.0 IiUFrM/3N R 0 A D 120.00 9� ✓' 3d 10 157.58-- 9, i + 455.0 IiUFrM/3N R 0 A D 120.00 9� ✓' 3d SEC. CORNIER 21-22-27-2 U S. G. L. O. MONUMENT G a 30 p�\2 157.50 I 1 10 157.58-- 9, 0 3,306.95 SO FT v (� ( I I - — ---� ----- of ----------- u-) 33,556.95 SO, O 1 32,595.65 SO FT 1 187.50 ! I I 1 187.85 I I I I 1 I ! � _ M I N — QN — N0 8 v 0 0 N 40,328 01 S0. FT �G O LLJ 0 20 o F— 1 N °' W i i,.3ri6.9 SQ FT W I cr �I ! JI I C) \ti oN M 120.00 p� v1 0 8 co o 0 40,218.75 SO. FT. i 1� 40,393.56 S0. FT. N 1 I I 110 187.50 ! 188.47 1 1 SET MONUMENT 1 1 I MARKED 650-S, 1965 I 185.00 9j v 1 m 7 Lq a 40,218.75 SQ. FT. 1 N I I _a 40,461.00 S0. FT. N I I ------187.50---J I I I I � 188.78 ------------ r -1('X90' 10 0 131.95 SO. FT. 215.00 I 0 0 0. _ U) t "; cr rn O ,550.00 SO. FT Z --^-15.00------ I SEC. CORNIER 21-22-27-2 U S. G. L. O. MONUMENT G a 30 p�\2 157.50 I 1 N M NOT r 157.58-- 9, ( I o 10 m y u-) 33,556.95 SO, FT. I 1 32,595.65 SO FT 1 187.50 ! I I 1 187.85 I I I I 1 I ! � _ O un I N — QN — I 8 v N 40,218.75 SO. FT. 1 N 40,328 01 S0. FT �I LLJ 21 1 wl I a1 w 1 187.50 I oo Ir �I ! JI I C) oN 1r)� 0 � 3 1 v1 0 8 N � G V 40,218.75 SO. FT. i 1� 40,393.56 S0. FT. N 1 I I 110 187.50 ! 188.47 1 1 SET MONUMENT 1 1 I MARKED 650-S, 1965 I p 4 I I 1 `i 1 I 1 m 7 Lq a 40,218.75 SQ. FT. 1 N I I _a 40,461.00 S0. FT. N I I ------187.50---J I I I I � 188.78 ------------ r -1('X90' N M NOT r T111-1 2-28-77 All Samples A 0.01 ORGANIC MATERIAL GTUNDING ^( TO ORGANIC SILT — �IY/ d'• SANDY SILT 1.4/SOME GRAVEL (ML) Brown, Medium Dense Note- Test dole locations are approximate and have not been located by survey methods. This log represents subsurface soil conditions within Lot 1, Block 4, i:e�,4a n Subdivision, anchorage, Ak �VRZ TES 11 HOLE LOG A14D Ey l R&rV] CONSULTANTS, INC. T•OCATION DIAGRAM =., .... ...........,. 2-2877 ..., ANCHOPAGr, ALASKA E 1"-3' F.B. fiUFFNAN ROAD e --- — — —6.0-' 30' e TH-1 40' °, o o° Lot 1, ; • o � I➢ LH.' [�' Bloch -4, Dee H 6ici9ann Subd. U) Ca SANDY GRAVEL a ade 0 °eo° W/TRACE SILT (GW) LP n eea r7 pae ey° y S ° ° (J OOe e ° DQ O e OO ea O 13.0' TD Note- Test dole locations are approximate and have not been located by survey methods. This log represents subsurface soil conditions within Lot 1, Block 4, i:e�,4a n Subdivision, anchorage, Ak �VRZ TES 11 HOLE LOG A14D Ey l R&rV] CONSULTANTS, INC. T•OCATION DIAGRAM =., .... ...........,. 2-2877 ..., ANCHOPAGr, ALASKA E 1"-3' F.B. GR!D 2834 PR0J3'J'0 751119 A-01 ON 1 y =o 2m O D 0 D C x Gf {,1 m.'o m 3 3m 2mR[ n,0 p m m N O N J m 3 - - m E j 2 3 O N d _. v. W C _. F m m = O Z r 3 m 3 r y md N m 1^ 0 M o F m o m D O1 V n N N c yti ' O m a D� d d NFA o`u N 3 mm j n m 2l0 ; z 10 m z C '� m G K O D d N N Q O N y R j F M - a a a N N (A ON O m 0 D m m N 2 O T J O T O � T d7 2 u_ p D O D n 0 c 0 O N N b 3 J O O a 0 N mcm° J o 3n O" N ry O - d n A `G v O m J 0 d ^ m ] b' c c ] o m m m ro 3 n a o o U o a ,a d H s m' F Mal r ✓ f Y 4t4 14A Y.. s: LORRIN r E { RC �>•4Y r = ,,•tdlOP1\'�H�lyd9 Y_. tt1lkS.`Y,:s 'I, .:�il:'��1' :y';'+, .t':i` Ixo i.:�n]w.'•. December 29, 1978 #780297 Bob Goentzel Star Route A Box 1562-D Anchorage, Alaska 99507 Subject: Lot 1 Block 4 Mc Mahon Subdivision A permit issued by this department for well and/or sewer system has expired. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal ordinance. If you have drilled the well, a well log should be sent to this department to document the installation date. If there are any further questions, please contact this office at 264-4720. Sincerely, Les N. Buchholz, R.S. Senior Environmental Specialist LNB/l j w enc: copy of permit 30 March 86t 1978 97062 Bob Goantzel 612 h East 14th Avenue Anchorage, Alaska 99501 Subjects Permit Expiration A permit issued by this department for well and/car on-site seater installation on Lot 1 Block 4 Mc Mahon Subdivision has expired since the issue date exceeds one(l) Year. In the event You still plan to install the well azar:/or on- site sewer system, a now permit is require.. The original soil test may be used to obtain a current permit, if the well has been drilledp a. well log should be sent to this department to document the installation €late# if you have any q4etions regarding the above matter# Please contact this office,,*i1ediately at 264-4720. Sincerely, Les N. SuchholZ, R.S. Senior Environmental Specialist UiB/lj h