Loading...
HomeMy WebLinkAboutMCMAHON #1 BLK 7 LT 4McMahon Block 7 Lot 4 #017-361-20 . · Municipality of Anchorage r .  Development Services Department o~ ~,, Building Safety Division On-Site Water & Wastewater Program. 4700 Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of On-Site Wastewater Disposal System and/or Well Inspection Report permit Number:. SW080098 PID Number: 017-361-20 "~°:BOB MURATI Wastewater System: I-1 New · Upgrade 3650 DOROSHIN DRIVE *ANCHORAGE, AK 99516 ABSORPTION FIELD Ph°ne:/'907~ / 345-6295 3 · Deep Trench O Shatlow Trench i'l Bed I'1 Mound [] Other LEGAL DESCRIPTION 1.2 ~0/~. r~ 12 7 4 MCMAHON #1 7 - - - SEE DWG. WELLI D New n Upgrade 3 ,. 400 ,.,.,. o o3 /F- to ~. ~,,'~.~: s,.,~ w~., ~: ~'"~' GEG ~*' ~'"~'~' 7/23/08 SEPARATION DISTANCES 0 s.pt~c rl Holdlng [] S.T.,F,~. ~ Tank rmld Station Tank See~ Unee ~.t_~: l~,~- Well tOO'+ 100'+ - - 25'+ s~,o¢o wot,, ~oo'+ ~oo'+ - - - LIFT STATION Cu~aln Drain NONE KNOWN I I ~,~o~k~: ,w~R t os0o~s BENCH MARK EXI~NG SEPTIC T~K W~ INSPECTED ~D D~ERMINED GAUGE S~B TO BE ~EUCTU~LY SOUND. Inspections pedormed by: GiG, Ltd. Dates: lSt2nd 7/237,23/08/08 3rd 7/23/08 ' Development Se~ices Depa,ment Approval ~.~ 4~ff~.~ ~ Conditional approval: Do[e: · AS BUILT DRAWING .~cE, ,o NUM.ER: pERMIT NUMBER: O17--361--20 SW080098 - / ~~ ~ / ,/ ,, MC N ~1: BLOCK 7, LOT 4 P.N.B ASBUILT DRAWING :' DRAWING ...cE.,..UMBER: pERMIT NUMBER: AS-BUILT 017-361-20 SW0800g8 FINAL GRADE'- = 97.29+ MT ORIGINAL GRADE = 96.70 FABRIC dVERT OF PIPE = 89.70 BO'FI'OM OF TRENCH = 84.70 ;LATIVE ELEVATION OF BO'Fi'OM OF TEST HOLE= 78.70 (DRY) GA"NESS EN G I NEE tR I :?.?.Ac.rOo~~ .... .~. · CONSULTANTS & GENERAL C T .............. ....~-------I ~,,~,~,~-,"~'~"'""""~"'~'"'" '"~'~""~ ' '-""'-" I,A ~111 I1,~-.~...I.-.,'-..~ o~ UURA~ I 345-6295 I ~c~Auo~ ~: ~LOCK ~. LOT ~ I ~~~"~';~g~/ PROFILE DRAWING MUNICIPALITY OF ANCHORAGE Development Services Depa~lmont On-Site Water & Wastewater Program 4700 South Bragaw Street P,O. Box 196650, Anchorage, AK 99519-6650 (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Jun 25, 2005 Expiration Date: Jun 25, 2009 Permit Number: SW080098 Legal Description: MCMAHON #1 BLK 7 LT 4 Design Engineer: 0855 GARNESS ENGINEERING GROU[ Owner Name: BOB MURATI Owner Address: 3650 DOROSHIN DR ANCHORAGE, AK 99516- Parcel ID: 017-361-20 Site Address: 003650 DOROSHIN AVE Lot Size: 43579 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for Ihe construction of: [] DisposalField [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage Ail construction must be In accordance with: 1. The attached approved design. 2. All requirements spec[fled In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day, B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. A. Permit includes a 0 foot lot line waiver from the proposed drainfield to the north property line. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastcwater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.¢i.anchorage.ak.us (907) 3430904 Waiver Review Worksheet WRg: 080038 PID#: 017-361-20 HA/Permitg SW080098 Date Received: June 26, 2008 Legal Description: MeMahon #1; Block 7, Lot 4 Engineer: Jeffrey Garness, P.E. Garness Engineering Group 3701 E. Tudor Road, Suite 101 Anchorage, AK 99507 Applicant: Bob Murati Waiver Requested: 0' Lot Line Waiver Criteria: Geology Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: Waiver is Granted: ){ Waiver is not Granted: . Ust Conditions or Reasons for above: Date: 1~26/0~ By: Jav Crewdson Name of Reviewer Rec#: 66444 Amount: $175 Date Paid: ~12§12~08 M ,uni ipality of Anchorag C /~ ,~',,~ · ~ ,. Office: (~R)7) ,~11 · I:lm (~X)7) 3~X) Mayor Mark Bcg~ch DcvclopmotL ~qccs Dcp~/mcnt Depar~mem June 26,2008 Jeffrey Garness, P.E. Garness Engineering Group 3701 E. Tudor Road, Suite 101 Anchorage, AK 99507 Subject: Waiver Request for McMahon gl; Block 7, Lot 4 Waiver Request WRg: 080038 Parcel ID # 017-361-20 SW080098 Dear Jeffrey Garness, P.E.: Your request for a waiver of the required 10 feet horizontal separation fi.om the absorption field to the property line has been approved. The approved separation distance is 0.0 feet. This waiver approval applies to the proposed absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincer. rtly, /'7 L/James "Jay" Crewdson, P.E. Civil Engineer On-Site Water & Wastewater Program Comntunity, Security, Prosperity Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERHIT ~,PPLICATION FOR ,b, SINGLE FAHILY DWELLING Parcel I.D. Property owner(s) BOB MURATI Day phone Mailing address .3650 DOR1SHIN * ANCHORACE. AK Site address Zip Code Legal description (Sub'd, Block & Lot ) ~I(;MAHON ~-1. LOT 4~ ~t.~)(~K 7 Legal description (Township, Section & Range) LotSize ("/~j 57~ Sq. Ft. ~/^ Number of Bedrooms 345-6295 THIS APPLICATION IS FOR ( [] all that apply): Absorption Field Septic Tank Holding Tank Privy Private Well [] Water Storage [] THIS APPLICATION IS AN: [] Initial [] [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUPf Ltd. Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) Waiver Fees: I "~ '~. (~ 0 GARNESS ENGINEERING GROUP, Ltd. *', :~ ~-: CONSULTANTS & GENERAL CONTRACTORS June 12, 2008 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic Upgrade for McMahon gl; Lot 4, Block 7, To whom it may concern: The existing 3 bedroom house is served by a private well and septic system. The septic system is in a state of failure and needs to be upgrade. We are proposing to install a deep trench type drainfield. One test hole was excavated on the property. The drainfield will be designed around the 30 foot radius ofthis test hole. Comments regarding the design are summarized as follows: I. SOILS: See the attached logs which show the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPiiY: As can be seen on the attached design drawing the average topography below the drainfield is a 5-10 percent slope running approximately south to north. 5. LOT LINE WAIVER: We are requesting a 0 foot lot line waiver from the proposed drainfield to the north lot line. The property line abuts a road right-of-way. As a result, there are no encroachment concerns, We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. Sincerel2 ', I /th a ess, E.,M.S. NOTE: Attached is a site plan drawing, a design druwing, one soil log, which are all part of the design package for this septic system. (Contact G.E.G. Ltd. for ?page construction specification letter.) 3701 E. Tudor Road, Suite 101 * Anchorage, AK 9950%1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 Website: www.garnessengineering.com BLOCK ,~ MCMAHON ~1 MCI, Ut&ION LOT gA ~LOCK 5 BLOCK 3 MCMAHON LOT 10 LOT 11 BLOCK ......... LOT 12 DORO~¢E. - './ ........ 7%~ ...... ~- MOMAHON ~1 BLOCK 7, LOT 4 P.N.B 3650 DOROSHIN ~ANCHORAGE, AK 99516 6/11/08 (Rev. 01~5) ~ DOROSHIN AVE. NUMBER OF DEDROOUB: '~ONS PER DAY (GPD): 450 C~O~ ~[RCO~ON ~/S: ; UINI~UM O~NRE~ wide: 2.5 rE~ . ~.0~ ~PRO~D ~D RL~R: N/A ~ L~[R ~T PERTNNS TO ~IS D~IGN. co~*~ ceo. BL~K 7. LOT 3 / I i ~/ ~ / ~ ~ ~ / uc~o. t,. / ~ ~ ~ .. .L~ ;, ~o; ~ '~ ~ . ~ ~~TH L~T -UN~, A~ WELL ~11 F~GGED BY A REGISTERED ~ND SURV~OR ~ ~ ~ ~ GAYNESS PROPOSED SEPTIC SYSTEM UP-GRADED DESIGN CERTIFICATE FOR A Parcel I.D. 017-561-20 1. GENERAL INFORMATION Municipality of AnChorage Development Services Depsrtment Building Safety Division On-Site Water & Wastewater Program 4700 E!more Road P.O. Box 196650 " Anchorage, AK 99519-6650/j~/? www.muni.orglonsite t /' (907) 343-7904 //r OF ON-SITE SYSTEHS APPROVAL SINGLE FAHILY DWELLING COSA# ExpirationDate: ~/~ /'/ Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address MCMAHON #1; BLOCK 7, LOT 4 5650 DOROSHIN DRIVE *ANCHORAGE, AK BOB & CINDY MURATI 5650 DOROSHIN DRIVE Day phone *ANCHORAGE, AK Day phone 545-6295 BETHANY MEHNER W/ PRUDENTIAL Day phone 762-3111 3801 CENTERPOINT DRIVE #200 ~ANCHORAGE, .AK__99505 ........... Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 5 3. TYPE OF WATER SUPPLY: Individual Well · Individual Water Storage [] Community Class Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site · Individual Holding tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATE~'¢,ENT OF ~NSPECT!ON BY ENGINEER As certified by my seal affixed hereto and as oF the vafidation date shown below, t verify that my invest~ation, based on procedures outlined in the Certificate of On-Site Systems Approval GuNeiines for this appfication, s,i~,?v~ ,,,~, ~,,~ on-s~te water supply and/or ,~'~o~,,,~, '~o,~,o~ ~,,~,~m lo (are) s~~,~, fi~p, nfi~,q~t and adequate for the number of bedrooms and type of structure indicated herein. I further verify t,~at based on the information obtained fi'om the Municipality of Anchorage files and £'om my investigation and inspection, t.~e on-site water supply and/or wastewater disposal system is(are) in compliance with all appficable Municipal and State codes, ordinances, and regulations in effect at t,ffe time of installationo Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Phone 537-6179 Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for t,ffe sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE '¢-// Approved for -~-~ bedrooms~ Disapproved. Conditional approval for bedrooms, with the following stipulations' Septic System Advisory Well Flow Advisory Nitr.~.e Adv~soFy ? Arsenic Advisow Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: (Rev. 11/05) Municipality of Anchorage Development Services Department Building Safety Division ~' ==='"=':'"' '" ='''=' '''~ On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: MCMAHON #1; BLOCK 7, LOT 4- Parcel ID: 017-361-20 A. 'WELL DATA *PER AAROW PUMP AND WELL INSPECTION. SEE AFl'ACHED REPORT. Well type PRIVATE If A, B, or C provide PWSlD# N/A Well Log (Y/N) YES Date completed 7/9/197,:3 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth 98 f. Cased to *40+ ft. Casing height (above ground) 12+ JR. FROM WELL LOG AT INSPECTION Date of test 7/9/197,7, . 3/18/11 Static water level 76 ft. 71 ft. Well production 11 g.p.m. ,3.69+ g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi. Nitrate .** 10.7 mg./L. Date of sample: 3/18/11 Collected by: GEG, Ltd. SEPTIC/HOLDING TANK DATA Arsenic: ND ug./L. I**SEE ATTACHED AAROWI PUMP AND WELL REPORT Tank Type/Material SEPTIC/STEEL Tank size... 1000 gal. Number of Compartments 2 Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO Date of pumping 10/25/2010 Pumper... Date installed 4/29-30/1993 Cleanouts (Y/N) YES High water alarm (Y/N) N/A MCDONALDS PUMPING ABSORPTION FIELD DATA I'BELOW EXISTING GRADE'! Date installed: 7/'25/08 Soil rating (g.p.d./ft2o~.. 1.2 Length 40 ff. Width 3 ft. Total depth * 13.1 6 ft. Eft. absorption area.. ,400 ft2 Monitoring tube.**YES Date of adequacy test 3/18/11 Results (Pass/Fail) PASS Fluid depth in absorption field before test DRY in. Elapsed Time: ....!...75 min. Final fluid depth 2 Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN NOTE: PREVIOUSLY DOCUMENTED 197,3 CRIB AND 1978 DURING INSPECTION THEY WERE NOT IN USE AND DRY, System type ... DEEP TRENCH Gravel below pipe 5 ft. Depression over field......... NO For... 3 bedrooms Water added 630 gal. New depth .....7.5 in. in. Absorption rate >= 450+ g.p.d. If yes, give date ...... - TRENCH ARE CONNECTED AS RESERVE SITES. **SEE ATTACHED LETTER. LIFT STATION Date installed "Pump on" level at __ .in. E. SEPARATION DISTANCES Size in gallons "Pump off" levet_.a~. Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot 100'+ Public sewer main N/A Sewer/septic service line 25'+ Animal containment areas 50'-I- 100'+ Ma n hole/Access (Y__(.(.(.(.(.(.(~} ~ High water alarm level at Meets alarm & circuit requirements? ,in. On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout Holding tank N/A N/A Manure/animal excrete storage areas 100'+ Building foundation Water main Wells on adjacent lots SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: 5'+ Property line 5'+ N/A Water service line. 10'+ 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line *0% 10'+ Water service line Curtain drain NONE COMMENTS KNOWN *WR#0800 8 Absorption field 5'+ Surface water. 100'+ Building foundation 10'+ Surface water 100'+ Wells on adjacent lots. 100'+ Water main N/A Driveway, parking/vehicle storage 10'+ G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date _~'/~//' COSA Fee $ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Community Development Department Development Services Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Nitrate Advisory Certificate of On-Site Systems Approval # OSC111126 A Certificate of On-Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 7, Lot 4 of McMahon #1 subdivision. This inspection revealed a nitrate concentration of 10.7 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval. J LOT 5 W_ELL DOROSHIN S88'05'00"E 161.25' 'GRAVEL':: ~, O/W LOT BLK WELL 4 7 AVE SEPTIC VENTS (TYP) LOT 5 LOT 1 0 ANCHORAGE RECORDING DISTRICT ASBUILT OF: McMAHON SUBDIVISION FIRST ADD. LOT 4 BLOCK 7 PLAT 71-317 SURVEY CERTIFICATION: I, John L. Schuller, have conducted a physical survey of this property as shown on this drawing and that the improvements situated thereon are within the property lines and no enchroachments exist other that noted. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. Under no circumstance should any information on this drawing be used for construction of fences, structures, improvements, or for establishing boundary lines. WORK ORDER NUMBER: IDA'IE; [SCALE: I^PR ~8, 2o1~ I 1"=3o' I 11 01 5 I I JLS I 2835 I 110111 ~ . 1831 Talkeetna Street Anchorage, ~aska 99508 (907) 227-1455 office (907) E74-499E fax GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS April 27, 2011 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: McMahon Subdivision #1; Block 7, Lot 4, Monitoring Tubes; Mr. Poet: The primary drainfield on the property was installed on 7/23/2008. It was installed and documented by GEG, Ltd. Per our as-built drawings, there were two monitoring tubes installed in the drainfield. On 3/18/2011, we inspected the property for the purpose of obtaining a C.O.S.A. During our inspection, only one monitoring tube could be located. After we had installed the system, the owner had arranged landscaping work that apparently concealed the east monitoring tube. Since only one monitoring tube is necessary, we request you approve the system in its current condition, noting that one pipe will be missing from the current as-built survey. If you have any questions, please contact us at 337-6179. Sincerely, ~.~ . Jeffrey P/~arnesS, ~ M.S. President Thank you for your assistance. 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com 2011-05-02 07:47 AAROW PUMP & WELL 18882806416 >> Fax P 1/1 Aarow Pump & Well Service LLC (907)346-9355 Inspection Report 3650 Doroshin, Anchorage Well was inspected by camera down to 43'. No perforations or leaks were found. Well was then nm for 20 hours and re-sampled for nitrates. Second nitrate test came in at 8.79 from 10.7 previously sampled by Garness Engineering,<~ter this testing it is obvious the nitrates are not coming from this well. Aarow Pump & Well Service LLC GAllNLSS ENGINEERING GROUP, Ltd ~;~ [ ........... COhlSULTANTS&GENEI~ALCONTRACTORS .................... L~.~l.~..' ~ ~:~,r~J/ ,,o,~.~,o,.~,.~,,,~,-,,,,.,~,,,~-~,.~~-~-:"' ";'~ .... ISOIL LOG - PERCO~TION TESTJ ~'~t' DEPTH ~ O~GNICS (f ....SM~~ GROUNDWATER ~ ~~ ~.;~.'~ ~ .. SOl~ ITEST DEPTH TO ' "., DD~ RY GP GW C~SSIFICATIONSGCGMSC SM SP SW HOLE~ TT~ ..... ..... --~ h 0/22/200; ,/0 ~1, DATE 1/200; CL ML ORG CH MH OL OH ~'" '~/ ~~// .....~~ ~ N' . '.{ '~/ /~/'' --_ ::''' ~t~ '~ ---- ~] // ,/ ''. ,/ / TH,~, 11 : DATE READING CLOCK NET TINE WATER LEVEL NET DROP  TINE (HINUTES) READING (INCHES) 12 10/23/2007 1 3:00 - 6- _ 2 3:30 30 0 6" 13 ~.t;~;' 3 3:30 - 6" ~ ::~:~ ~*"* 4 4:00 30 0 14 'e%'J 5 4:00 -- 6" -- '.'J~ 6 4:30 30 0 6" 15 %%*' SP TO SP-SM 17 %'*' ' ~ PERCOLATION RATE 5 (H[N./INCH) PE~C. HOLE DIA. 6 (INCHES) 1~{~ TEST RUN BETWEEN 7 FT. AND 7.5 FT. 20~ A FOUR HOUR PRESOAK WAS PERFORHED: ~ YES ~ NO SOILS LOGGED BY: SU~N OSWALT PERCOLATION TEST PERFORMED BY: PIERCE COHHENTS: PERFORMED BY GEG, Ltd. I, JEFFR~ A. GARNESS, CERTI~ THAT THIS WAS/P~RFORMED IN ACCORDANCE WiTH ALL ~ATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL SUBMITTAL COMMENT SHEET To: Legal description: McMahon #1; Lot 4, Block 7 [~Permlt ["]C.O.S.A. [-'llnspection Report The attached paperwork has been reviewed and is being returned for the following reasons: 1. It appears the proposed drainfield may be near a roadside ditch. Please substantiate the horizontal and vertical location of the proposed dra[nfield in relation to the topography in the adjacent right-of-way. Name of reviewer: Jay Date: 6119108 Please supply the necessary information and re-submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Repo. rt Permit Number: -%l'v' ~JOO'TC~ PID Number: O1'73~120 Name:~O~E~T ~U R~TI Wastewater System: B No~ ~grade Address: 3G50 bORoSH ~ AVE, ANC¢ , ?~S/6 ABSORPTION FIELD NO. of Bedrooms: Phone:~ ~ ~ ~ Deep Trench ~ Shallow Trench D Bed ~ Mound DOther LEGAL DESCRI PTI ON so,, Rating: Total Depth from original grade: GPD/Sq. Ft. Lot: Block: Subdivision: Depth Io pipe botlom from original grade: Gravel depth beneath pipe 8' ~ 4cM4HO~ ~ ~ Ft. Ft. Township:[ ~ ~ Range: ~ ~ Section:~ Fill added above original grade: Ft. Gravel length: Ft., WELL: EXlSTiN~New~ ~ Upgrade Graveldepth: Numberer gnes: Dislance~lweenli,es: Ft. Ft. Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: Ft. Ft. ~ SQ. Ft. Driller: Date Drilled: Slalic Water Level: installer: ( ~ ~ ¢~1~ J Date installed: Yield: GPM *.rap Set at: Ft. Casing Height Above Ground:Ft. TAN K SEPARATION DISTANCES ~Septic U Holding ~ S.T.E.P. TO Septic Absorplion LiFt Rolding Puhlic/Prival(~ Mantlf~Clllr~r: Capacity in gallons: From Tank Field Station Tank s .... .,... ANCfloRA~¢ TAN~ Iooo Number of Compartments: Well ] JOt Materiel: ¢~EEL Surface Water >/~' LIFT STATION LineL°t ~OI Size in gallons: ~ Manufacturer: I Foundation ~ I "Pump on" level al: "Pump off" level at: High water alarm at: Cu~ain Pump Make & Model Electrical Inspections performed by: Drain BENCH MARK Remarks: N~ ~n~ I~l/e~ Location and Description: Assumed Elevation:~ ~[Op Tec~n~cc] Se~ices ENGINEER'S SEAL Inspectionspe~ormedby: ~LA~OP TEC~ 5YC~ Dates: lst q/2q/~3 ~w : ~'--~ Department of Health~d H um~rvices approval ~'¢.~.~ .~,~'. c[". 3~s¢~' ' ..; ~ ~,~_ Reviewed and approved by ' ~ Date' 72-013 (1/91) MOA 25 P'ermit No. 5 i4/c~ 3 4::)O '7°/ Page ;2 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report LegalDescription: LoT q¢ 'BLK"J/ ~4c/VJAt~ON PIDNo.: ~173(0120 72-013 A (Rev. 9/91 ) MOA 25 piT' looo gAL. ~£P. FlcdtoP Technlcc! Ser~ ces 14530 Echo Street Anc;horc~g-e, Alaskc 9~ ~e ENGIne'S SEAL '0 '~*', ". C~ ~ ." ~ ~ ~ ~ % ..' .,e.~ Permit No. ~l,v' c~3C)O --/c/ Page ~ of '~ Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: LOT ~ BLK' "7¢ HC H/~HOt~ PID No.: 0 1'7 ~Glzo No I-JoR t~oN ?AL SCALE 72-013 A (Rev. 9/91) MOA 25 ELEV= I00.0~ Fiattoi5 Technica! Servic~ 14530 Echo Street ~fiChorage, Alaska 9951t MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF 1 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW930079 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:MURATI ROBERT E & OWNER ADDRESS:3650 DOROSHIN AVE ANCHORAGE, ALASKA 99516 DATE ISSUED: 4/29/93 EXPIRATION DATE: 4/29/94 PARCEL ID:01736120 LEGAL DESCRIPTION: MCMAHON #1 BLK 7 LT 4 LOT SIZE: 43579 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4329 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: THIS PERMIT IS FOR A COLLAPSED SEPTIC TANK ONLY. THIS IN NO WAY CONSTITUTES APPROVAL FROM THIS OFFICE OF THE COMPLETE WASTEWATER DISPOSAL SYSTEM. RECEIVED B Y:,,_if~ ~ DATE: DATE: I.. 31~ LOT 5- C~pT~C l~Ic~top Technical Services 14530 Echo Street Anchorage; Alaska 9951~  MUNICIPALITY OF ANCHORAGE ,; ~* DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 TeLephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ~ NO. OF BEDROOMS ~l[Wel~/~ Absorption area Dwelling PERMIT NO. ~ ~ DISTANCE TO: ~ ~ Manufacturer Material No. of compartments ~ ~ Liq. capacity in gallons IF DE: Inside length Width Liquid depth ~ ~ DiSTANCETO: Well [ ~X4 Dwelling PERM,TNO. O Z ~ Manufacturer Material Liquid capacity in gallons Nearest lot Hne ~= DISTANCE TO: Well XO¢~ Foundation ~ ~ ~ No. of lines ~ Length of each lin~ ~ Total length of ,ine~ ~. Tren5 ~¢,h Distance between lines ~ -- Top of tile to finish ~rade ~ ~ Material beneath tile Total effective abso~tion Length f~ /~ ~ Width ~ Depth PERMIT ~O. ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line ¢ DISTANCE TO: Class (~ Depth Driller Distance to lot line PERMIT NO. ~ DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS ¢ ~ SOIL TEST RATING INSTALLER REMARKS ~PPS~ VED -~ DATE LEGAL 72-013 (Rev. 3/78) 6~--_~'I"E 780440 ~iT ~LIGANT SAMUEL SPEZIALE _OCATION DOROSHAIN DR. LEGAL L 4 B 7 MC MRHON Ir-'JLIl'-,! -r F_: I F'RL ! T¥ I:,F FIN¢:~ DEPARTMENT Or'-~"'HERLTH AN[.':, ENVIRONMENTAL F'~OTECTION 264-4?20 SRA BO,',-.', t55t-T RNCH 99507 TYPE OF SOIL 8BSORBTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOblS = '~ SOIL RATING ,::S~. FT/BR)= "'.~ THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: [:oEF'TH= 14 LENGTH~ 22 m]RR',/EL lC_-, E F" T H = LOT SIZE 42..:579 SQUARE FEET THE LENGTH DIMENSION IS THE LENGTH <IN FEET) OF THE TRENCH OR [>RRINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE E~C8VRTION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). PERMIT RPPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY NEL.LS ADJACENT TO THIS PROPERTY AND THE NUMBER OF' RESIDENCES THAT THE WELL WILL SERVE. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBSECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN 8 WELL. AND ANY ON-SITE SEHRGE DISPOSAL SYSTEM IS ±00 FEET FOR A PRIVATE'WELL¢ OR i50 TO 200 FEET FROM 8 PLIBLIC WELL DEPENDING UPON THE T'¢PE OF PUBLIC WELL OTHER REQUIREMENTS MAV 8PF'LY. SPECIFICATIONS RND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F"ERr-1T T E×P I RES [:-,EL-:Er-IE:ER 3::[-.., :1"'_.-~- '78 I CERTIFY THAT i: I AM FAMILIAR WITH THE REG!UIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET FORTH BY THE MUNICIPALITY' OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CO[:,ES. ~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REt;!UIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THRN 3 BEDROOMS. / / RF'PLICRNT SRMUEL SP~Z~LE I SSLIE[:' ---D "'" ~ ~' GR~J'TER ANCHORAGE AREA BO~ ')UGH x Department of Environmental Quality 3330 C Street "'~ Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE L'~ O' EROM WELL ~?~_?~^N,~EACTO RER~4 ~,&. INSIDE LENGTH INSIDE WIDTH NUMBER OF LIQUID DEPTH LIQUID CAPACITY ~ ~)(~ (~) GALLONS. SEEPAGE PIT: NUMBER OF PITS J DIAMETER__ORWIDTH ~',. LENGTHJZ~;, DEPTH LINING MATERIAL\O~¥'\g CRIBSIZE: DIAMETER~' DEPTH GIDISTANCE FROM: BUILDING FOUNDAT ON$~)/ ~O' TOTAL EFEECTIVE . NEAREST LOT LINE -, . ABSORPTION AREA (WALL AREA) O SQ. FT. ADDITIONAL ABSORPTION ~0~'~ ~ WELL: ~ \ TYPE ~¥~\.) A8 ~V-', [~.~'.O CONSTRUCTION BUI LDING NEAREST NEAREST FOUNDATION __ LOT LINE SEWER LINE CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMARKS DEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK __ SYSTEM DISTANCES: 5~'~ O~.'.'~ ~"~ PIPE MATERIAL, ~(~.\ ~11 LOT SLOPE: ~.~ Form No. EQ-031 DIAGRAM Of SYSTEM APPROVED ~),/',,rX.¢'¢",.-~ - ~:;~t~ ' G.A.A.B. GREATER ANCHORAGE AREA Borough PERMIT NO. DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 SEWAGE DISPOSAL SYSTEM w APPLICATION AND PERMIT NAME OF APPLICANT ,/~-~-'7--- 7'(j~/U'/ INSTALLATION LOCATION /~/~A/L://~/~ /~/~ MAILING ADDRESS PHONE . iNSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED SEEPAGE PIT K~ , DRAIN FIELD FINANCED THROUGH COMPLETION DATE ANTICIPATED , OTHER. TO BE INSTALLED BY //~° NOTE: THIS FERMiT 15 NOT VALIB WITHOUT 5OIL FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE /~ ~- TYPE ~/~ ~ ~/~E~SEEPAGE AREA SIZE /~/ ~'~ ~ ~! ~ MINIMUM DI$~rANCE$, REQUIRENIENT~ FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT ~ ~) / / SEPTIC TANK TO SEEPAGE Pit Wall /J SEPTIC tANK ~/ '~, SEEPAGE PIT / TO NEAREST LOT LINE. / ~EL[- TO SEPtiC TANK ~) . SEEPAGE DRAIN Field WATER MAIN TO SEPTIC TANK DRAIN FIELD TO RIVER, LAKE, STREAM. .. DRAIN Field ALSO CONSIDER AREA WELLS. ., SEEPAGE Pit DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOil. 4 INCH DIAMETER CAST IRON S~PHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. OR DIAGRAM Oi= SYSTEM ~//~/~ ¢ APPLICANT'S SIGNATURE Performed For R. Stanton Legal Description: Lot 4 Block This ~orm Re,orts Soils Loft Yes "One trust is wo~t~ a th~$anc~ o~inions" Date Performed ? SubdivisionMcMahon Subd±v±sion Percolation Test Deoth Feet Soil Characteristics OverOur~n 5 6 Bnttom of test hole at 14 ft. Was Ground Water Encountered? IF Yes, At what Depth? Reading I.. Date Gross Time Net Time Depth to H20 I Net Dron L ~., 1. ~ I ' ! Percolation Rate ~tinute Proposed Installation: SeepaGe Pit Drain Field Depth of Inlet Depth To Bottom Of Pit Or TrenCh C~M~ENTS: 8~sq. ft. drainage area required per bedroom No bedrock or water table four_~'t, below.se~page.pm~ Test Performed B.yjim Mack, Lab Manage~ Data Certified By:Construction Eestlab ~ Da te :~/16/73 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date ~_p'"r.., :' ;.!' GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Location (address or directions) (b) Applicant Name ~_~i~_~L~- ~,; Telephone: Home Applicant Address Business (c) Applicant is (check one): Lending Institution []; Owner/builder/~; Buyer []; Other [] (explain); (d) Lending Institution Address (e) Real Estate Company and Agent Address ~'~1 ~ ~¢~ Telephone ~- (f) Mail the HAA to the following address: Telephone TYPE OF RESIDENCE Single-Family~ Multi-Family [] Number of Bedrooms ~'~ Other WATER SUPPLY Individual Well~ Community [] Public Note: If corn munity well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite/~ Public [] Community [] Holding Tank [~ / Note: If community well system, must have written confirmation from the State Department of Environmental Conservabon attesting to the legality and status. 72 I o t11/84) Page 1 of 2 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water suppJy and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or v/astewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm %~/~:~ ~--~1 "~~'~''~'t~F '~' ~- Telephone Address Date DHEP, APPRO.~., A _ Approved for Approved bedrooms by~~. ~at e Disapproved Conditional Terms of Conditiona! Approval' CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes an~J their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections o analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in t' professional engineer's work. Page 2 of 2 MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST- FEBRUARY 1984 264-4720 Legal Description: J..OT WELL DATA Water Sample Collected by Water Sample Test Results . Comments '~ ~Y',~-~.~ Well Classification Well Log Present (Y/N) Total Depth J OO' Static Water Level Casing Height Above Ground Electrical Wiring in Conduit (Y/N) Separation Distances from Well: To Septic/Holding Tank on Lot · To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line NOI~L~ Cleanout/Manhole NoN ~-~ Cased to No'~¢ u~4 Depth of Grouting N '7 7 Pump Set At Sanitary Seal on Casing (Y/N) ¢~' Depression Around Wellhead (Y/N) ifA, B, C, D.E.C. Approved (Y/N) l~/f~ Date Completed ~) v~ ~4~ Yield ~"~ ~=~>~ I l'7 F'~' ; On Adjoining Lots I'~'~ ; On Adjoining Lots To Nearest Public Sewer To Nearest Sewer Service Line on ; Date B. SEPTIC/HOLDING TANK DATA Date Installed /~-1~-7.~ Size I-OOO No. of Compartments TWO Standpipes (Y/N) O ~/:~ Air-tight Caps (Y/N) ~ Foundation Cleanout (Y/N) Y Depression over Tank (Y/N) N Date Last Pumped ~ ' ''~' Pumping/Maintenance Contract on File (Y/N) l'¢/'~ ; for Holding Tank High-Water Alarm (Y/N) l,¢/"~, Temporary Holding Tank Permit (Y/N) Separation Distances from Septic/Holding Tank: To Water-Supply Well To Property Line To Water Main/Service Line Course To Building Foundation To Disposal Field To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata ~J~ Date Installed 7'~ o~,~ ~'~ Width of Field /'~-~ 'f Square Feet of Absorption Area Depression over Field (Y/N) /'%/ Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well / To Building Foundation ~.-~ Lot To Water Main/Service Line 2' / 0 To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments Type of System Design Length of Field ..~ '~, Depth of Field Gravel Bed Thickness Standpipes Present (Y/N) Date of Last Adequacy Test To Property Line ,.~ To Existing or Abandoned System on ; On Adjoining Lots To Cutbank (if present) NoN,~ D. LIFT STATION ~ ON/----" Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MOA and HAA g uidelines in effect on the date of this inspection. E'~'" .S Signed '"~. ~ Date ! Company 7'<~/¢~,4 ,~ur~L~.,~gtC~.,t~ MOA No. Receipt No. '-~ "~'q '~ 6'/ Date of Payment Amount: $ C( ~' . Page 2 of 2 72-026 O1/84) Engineer's Seal CONSULTING ENGINEER ~03 W. 15th AVE "C" SUITE 203 ANCHORAGE, ALASKA 99501 TELEPHONE: (907) 279-3916 SEPTIC SYSTEM ADEQUACY TEST LEGAL: LOT 4, BLOCK 7, MC MAHON LOCATION: 3650 DOROSHIN OWNER: SAMUEL SPEZIALE RESIDENCE: SINGLE FAMLIY, THREE BEDROOMS WATER SYSTEM: ON SITE WELL DATE OF TEST: TEST PROCEDURE: FROM MUNICIPAL RECORDS: TANK: STACK STEEL, STEEL, TWO COMP. 1000 GAL. ABSORPTION SYSTEM: CONCRETE CRIB AND TRENCH ABSORPTION AREA:360 SQ.FT AND 264 SQ. FT. SOIL RATING: 85 INSTALLATION DATE: CRIB IN 1973, TRENCH IN 1978 SEPTEMBER 4, 1985 SEPTEMBER 4, 1985 SYSTEM WAS INSPECTED ON SEPTEMBER 3, WATER WAS ADDED TO THE TRENCH UNTILL 1985, WATER FLOWED INTO THE CRIB. ON SEPTEMBER 4, WATER WAS AGAIN ADDED TO THE TRENCH AND THE WALER LEVEL MONITORED.A TOTAL OF 400 GALLONS WERE ADDED CAUSING A RISE OF 7 INCHES IN THE WATER LEVEL. AFTER 4 HOURS THE WATER LEVEL HAD SUBSIDED TWO INCHES INDICATING THAT 100 GALLONS HAD BEEN ABSORBED. EXTENDED TO A 24 HOUR PERIOD THIS IS A DAILY RATE OF 600 GALLONS. TEST RESULT: THIS SYSTEM MEETS THE CODE REQUIREMENTS OF iTHE MUNICIPALITY OF ANCHORAGE. The operational life of all septic systems depends on the local soil conditions, groundwater Ievels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this septic system. We can therefore not give any estimate of how long the system will continue to meet the operational requi- rements of the Municipality and State. 203 W. 15th AVE "C" SUITE 203 ANCHORAGE, ALASKA 99501 TELEPHONE: (907) 279-3916 RE S I DE N T I AL WELL I N S P EC T I O~N LEGAL: LOT 4. BLOCK 7, MC MAHON LOCATION: 3650 DOROSHIN OWNER: SAMUEL SPEZIALE TYPE OF WELL: RESIDENTIAL, SINGLE HOME WELL LOG AVAILABLE: NO INSTALLATION REQUIREMENTS MET: YES WELL YIELD FROM WELL LOG: NOT AVAILABLE PUMP YIELD: 6 GALLONS PER MINUTE DATE OF INSPECTION: SEPTEMBER 3, 1985 TEST PROCEDURE: WELL WAS PUMPED AT A CONSTANT RATE OF 4 GALLONS PER MINUTE AND THE DRAWDOWN MONITORED. STATIC WATER LEVEL WAS 77 FEET, AND TOTAL DEPTH 100 FEET. AT 4 GALLONS PER MINUTE THE DRAWDOWN STABILIZED AT 80 FEET. TEST FOR COLIFORMS: WATER WAS TESTED ON SEPTEMBER 4, 1985. TEST WAS NEGATIVE. TEST RESULT: THIS WELL MEETS THE REQUIREMENT OF THE MUNICIPALITY. The Municipal requirement for well flow is 150 gallons of water per bedroom per 24 hours.This well surpasses this requirement. The assessment of the condition of this well applies only to the conditions as of this date. The flow rate of the well may change due to subsurface conditions that may not be observed from the surface, and changes in land use and other factors that may impact the conditions of the aquifer feeding the well. GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage., Alaska 99503 274-4561 Date Received November 17, 1976 Time of Inspection Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR 4. 5. 6. Approval requested by: Mailing Address: Property Owner: Mailing Address: Legal Description: Location: Cony. Home Federal Savings & Loan 535 D Street Robert J. & Charlene F. Stanton Box 1551-T Star Route A Lot 4 Block 7 Mc Mahon #1 Doroshain Drive Phone: 272-1451 Phone: 344-0501 Type of facility to be inspected Single Family Well Data: A. Type Individual C. Construction Sewage Disposal System: A. Installed 9/73 C. Septic Tank: 1. D. seepage Pit: 1. E. Disposal Field: Total length of lines No. of bedrooms 3 B. Depth D. Bacterial Analysis On-site system B. Installer Size /~ 2. Manufacturer~~d. Absorption Area .~0' 2. Material /~ /'~ , Absorption area Other contamination , Absorption area Distances,~ A. Well to: Sep{ic·tank Nearest lot line B. Foundation to septic tank C. Absorption area to nearest lot line , Sewer Lines __ EQ-034 (1/74) Page 1 of two pages ',Page 2 o7 two pages - Re' ~st for Approval'of In'dividual ~er & Water Facilities ,Le'gal Description Lot 4 Block 7 Mc Mahon #1 Comments .. Approved : Disapproved Date Approvali. Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM I certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and. water facilities and these facilities are operating satisfactorily. SIGNED Date EQlO34 (1/74) MUNICIPALITy OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 2510 East Tudor Road, Anchorage, Alaska 99504 276-222i REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES MUNICIPALITY OF ANCHOP, AGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION~ NOV 1 ? 1976 : RECEIVED 1. Type of Inspection: CMRO VA FHA CONV 2. Property Owner: '~0/~¢-J'T- '--J' ~ 0_/~/~c~-t~ /%. Mailing Address: ,_~'X J~'J-'T- /g/&. cJcig)?DayPhone: 3. Name of auyer: ~/)¢~tCLeC. '~, 4- ~ ~l-%-Fl~ ~. Mailing Address: J~J~' -~oJC ~ /~. ~1¢1'?O'7 DayPhone; 4. Name of Lending Institution: /'~-O~- ~--~(Z/gc- ~'/~d~/~ . Mailing Address: ~%~ Name of Realtor or Agent: ~~ Mailing Address: ~ Legal Description: (~ Location: ~ ~ '~~ Type of Facility to be Inspected:/~ ms. Water Supply TYpe of Supply: Public Utility. IndiVidual If Individual, number of dwellings presently served C)t~' If Indivi.dual, depth of well C)/~ ~ Sewage Disposal System Type of System: Public Utility Individual (on-site). If Individual, date of installation ~e*~- ~ i~"-/~ 72-O03(3/76} July 13, 1978 R&M No. 851555 Mr. Sam Speziale Doroshin Drive Anchorage, Alaska Re: Adequacy Test on Existing Sanitary Sewer System; Lot 4, Block 7, McMahon Subdivision, Anchorage, Alaska Dear ~lr. Speziale: Per your request of July 7, 1978, we conducted a test of the sanitary sewer system on the above described property. The septic tank was pumped and water was added to the log crib. During the test, the liquid level in the crib was measured before and after the addition of 200 gallons of water at which point the crib was full as indicated by a backflow of water into the septic tank. The total depth of the crib was 11.4 feet. All liquid levels were measured below the top of the standpipe and are summarized in the following table: Liquid Level Before Water Added Liquid Level After Water Added Total Rise in Liquid Level 5.5' 3.6' 1.9' The water level rose 1.9 feet or 22.8 inches with the addition of 200 gallons of water, indicating an acceptance rate of 8.8 gallons per inch in the crib. Twenty-four hours later the liquid level was again measured and found to be at 6.6 feet. It had dropped 36 inches. This indicates an average effluent acceptance rate of 316.8 gallons per day for the surrounding soils. If the three bedroom residence on the property is to house 6 people, the average load on the system can be expected to be 450 gallons per day. We can, therefore, conclude that the system is not accepting effluent at an adequate rate for a 3 bedroom residence. We appreciate this opportunity to be of service to you. If you have any questions regarding this letter please contact us. Very truly yours, R~4 CONSULTANTS, INC. Lynne Kosikowski Staff Geologist Gary ~Manager GS: LK/kah To, .~{ome Federal Savings and Loan AT 835 D Street 99501~~ ~ SUBJECT Lot 4 Block 7 r,{c Mahon Subdivision $1 DATE November 23, 197~ The 1977 construction season is ending due to seasonal cold weather. To date, this depc~rtment~ has no record of the Dpqrade being completed. DUPLICATE SIGNED -, .~ " "~ ~ ~ DATE SIGNED Redi~prm ® SEND PARTS 1 AND 3 WITH CARBON INTACT - 4S 469 PART $ WILL BE RETURNED WITH REPLY Poly Pak 150 sefs) 4P469 DETACH AND FILE FOR FOLLOW-UP