ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP221271 PID Number: 017-361-57
Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 0 Upgrade
Name
Howard & Debra Golden
ABSORPTION FIELD
KDeep Trench ❑ Wide Trench EJ Bed El Mound
Site Address
3741 Taiga Dr
❑ Other
Phone
Number of Bedrooms
Soil Rating
depth from original grade
4
125 GPD/SF
JTotal
11 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
4' Ft.
Gravel depth beneath pipe
7 Ft.
Subdivision Block Lot
McMahon #2 7 7
Fill added above original grade
0-21 Ft.
Gravel length
36 Ft.
Township Range Section
Gravel width
3 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
605 Fe
1
Ft.
Well
100'+
TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Capacity
Surface water
100'+
Gal.
Material
Number of compartments
Lot Line
13'
NA
Foundation
10'+
LIFT STATION
Manufacturer
Capacity
Remarks ALL PIPE IS PVC SCHEDULE 40 & CONFORMS TO ASTM 3034
Gat.
Alarm location
Electrical installed by
Installer
PIPE MATERIAL House to tank Tank to 3034
drainfield
A+ HOME SERVICES
Drainfield 3034 CO/MT3034
Inspector ANSON MOXNESS, PE
BENCH MARK (Assumed elevation)100' ft
Inspection 1°' 8/3/22 21d 8/3/22
da
Location and description
3rd am
Backdoor concrete
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
�4�•�
Conditional Approval: Date
.�4F
�•.•
9th ' � �:
�.......... ........................... .!..... ;
... ..;.ANSO S �
AV
Septic System
Approved L Date -�
®1�®;•.. No. C£-103906 V
♦ ��'P:�s®•r
Note: this approval does not Include well permit requirements.
eat'p*
ose
kruiv varucu io/
LINE TO SFR
EXISTING DOUBLE
Deep Trench, CLEAMUTS'
2' vide J
36' Long `
11' Max Depth Q 0 ---�}
7' Sewer Rock
4' Cover
EXISTING 1250 CALLDN SEPTIC TANK F
NQ SCALE
Trench Elevaflon (TyP)
Cl ea r►L,L4
Monitors
O.G. G/ V. 99.2-98,0'
9.ry -38.0p/Silt Barrier
TH1 A 11
1.1 �il 4' Cover Fr, r\ �a �'
PIPE INV
ELM 95.6
BOT TRENCH ELM 88.6'
7.0 Ft OF Septic Rock
801TOM TNI ELEV• -82'
NO GROUNDWATER
0BSUM ON 8/3/22
FGrWBATIaN
INV CUM 99.3' CL£AhWT
PIPE INV EUX 95.6' 1 1
EXISTING 1250 GALLLW HBPE SEPTIC TANK
SEPTIC SYSTEM ASBUILT
BATE, AUG 4 2022
SHEET, 3/3 GRID, 2835
PERMIT # OSP221071 PID #017-361-57 HCHAHON2B7LM ASBOVG I
\
ALTERNATIVE SITE,
WING n£S A B \ \ FIELD. 36° LONG TRENCH WITH t
F C.O. C 35.5, 32.0+ ,� �0 7' ROCK AMO STEP TANK OR LOT 6
Or M.T. D 36.5 335 sAMP STATION /
F C.0 E 32.5" 50.0'
F M.T. F 34.0' 51.0'SePt�c� � \. MCMAHDN #2 SID
(Area �' \ \ BLOCK 7
�J \
1 �L
LOT 8 /
3 BDRM
SFR
LOT 7 l
ABANDONED MnNG OWN
FIELD
INSTALLED 4-80ROOM DRAINFI£LD
CONNECTED TO EXISTING SEPTIC TANK
TRENCH LENGTH 36 FEETf
TRENCH W/DTH 2 FELT
MAX EXCAM70N DEPTH 11 FEET ��.�� ����♦
ROCK DEPTH 7 FEETOF
�� ............. ♦®♦
COVER 4 fE£TAF
®�P ;.••'
s
NOTE.' SLOPES EXCEEDING 25% WERE NOT OBSERVED 0�'49th •:�
A..............:WITHINETDOWN GRADIEM OF THE PROPOSED ""AZZMON RELD LOCAnON.0.y . ,. ..: ....;. ..�
�, .. ANQi# M XNESS
NOTE: THIS 15 NOT A SURVE7£D PUT. WELL & SMC , r No.CE-103906 •° o
LOCATIONS TAKEN fROM ON-SITE WATER AND WASTE WATER ♦ LA * ~ o
DEPARTMENT DOCUMENTAnON, ALL LOCAWNS SHOWN ARE I N `•• •?;�:.�``'• •�®
APPROXIMATE B�•p'e'
441,'
25 0 25 50 75 1011 125 150
SCALE., I' = 50 FT
ANSON MOXNESS PE KHMONAff 7 LOT 7 SEPTIC SYSTEM ASBUX
,�1,2
2439 DOUGLAS DR 11`
ANCHORAGE AK 99517 HOWARD AND DEBRA GOLDEN DATE: AUGUST 3 2022
907 242 5995 3741 TAIGA DR ANCHORAGE AK 99518 SHEET.• 1 1 GRID. 2835
PERMIT # OSP221271 PID #017-361-57
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax, (907) 343-7997
http:Nwww.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP221271
Work Type: Septic Upgrade
Tax Code Number: 01736157000
Site legal Address: MCMAHON #2 BLK 7 LT 7 G:2835
Site Mailing Address: 3741 TAIGA DR, Anchorage
Owner: GOLDEN HOWARD & DEBRA
Design Engineer: MOXNESS ANSON
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
n�cnt S
1°t �
�4f
I
ep:u•t�nEut
7/27/2022
7/27/2023
25978
Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received B
Issued By:
y Date:
Date: 71Z'7
4
MUNICIPALITY OF ANCHORAGE
Development Services Department
�� Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel I.D.
017-361-57
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Property owner(s) Howard & Debra Golden Day phone
Mailing address 3741 Taiga Dr Anchorage AK 99516
Site address Same
Legal description (Sub'd., Block & Lot) McMahon #2 Block 7 Lots 7
Legal description (Township, Range & Section)
Lot Size
Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR: APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
El(w/wo
Single Family (SF)
Absorption Field n Initial
ADU)
Septic Tank ❑ Upgrade 0
Duplex (D) ❑
Holding Tank ❑ Renewal ❑
Multiple Dwellings ❑
Privy ❑
(SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Siafla'fure of prop y owner or authorized agent)
Permit/Rush Fees: >! Waiver Fees:
Date of Payment: 1 5 0 Date of Payment:
Receipt Number: Receipt Number:
Permit No. Waiver No.
G:\Development Services\Building Safety\On Site Water and WastewaterTorms\Client Forms\Permit Application.doc
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221271, Deb Wockenfuss, 07/27/22
Wells:
There are no wells within 100 feet of the proposed system location.
The installation of this septic system will not prevent wells and septic systems from being installed on
the adjacent lots. There are no developed or natural surface /sub surface drainage courses within 100
feet of the proposed septic system location. The proposed septic system will not change the general
slope of the area. Ponding and/or concentration of surface runoff will not result from this installation.
ifv ou have any questions or are in need of additional information please contact me at 242-5995.
Sincerely
Je
Anson M xness, P.E.
2439 Douglas Dr, Anchorage, AK 99517
(907) 242-5995
anson.moxness@gmail.com
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221271, Deb Wockenfuss, 07/27/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221271, Deb Wockenfuss, 07/27/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221271, Deb Wockenfuss, 07/27/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221271, Deb Wockenfuss, 07/27/22
Municipality of Anchorage
On -Site Water and Wastewater Section • (907) 343-7904 Page of
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: 0SP191408 PID Number: 017-361-57
Dwelling: 9 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑■ Upgrade
Name
Howard & Debra Golden
ABSORPTION FIELD
❑ Deep Trench El Wide Trench ❑ Bed E] Mound
Site Address
3741 Taiga Dr
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
113
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Gravel depth beneath pipe
Subdivision Block Lot
McMahon #2 7 7
Ft.
Ft.
Fill added above original grade
Gravel length
Township Range Section
Ft.
Ft.
Gravel width
Beds: Number of Lines
Distance between lines
SEPARATION
DISTANCES
Ft.
Ft.
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Ft2
Ft.
Well
100,+
TANK IN Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Greer
Capacity
1250 Gal.
Surface Water
100'+
Material
Number of compartments
Lot Line
10'+
NA
HDPE
2
Foundation
10,+
LIFT STATION
Manufacturer
Capacity
Remarks ALL PVC IS SCHEDULE 40 & CONFORMS TO ASTM 3034
Gal.
Alarm location
Electrical installed by
Installer
PIPE MATERIAL House to tank PVCTank to PVC
drainfield
A+ HOME SERVICES
Drainfield CO/MT PVC
Inspector ANSON MOXNESS, PE
BENCH MARK (Assumed elevation) 100' ft
Inspection 15t 9/30/19
Location and description
dates: 2nd
3rd 4th
Backdoor concrete
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
_�®0®•apQ
OF A��s,
Conditional Approval: Date
"��
J. Aioximo .. .
Date 30 Zo21 . ��
���9Fc,'..No. . ==
�sl • No. CE 103906
Septic System ,
p y (1
CIA14
Approved I �(, ,A V Date (o 17� /20��
• �,
�
Note: this approval does not include well permit requirements.
N,
/0'
� LOT 6
Areaic� / . MCMAHON #2 S/D
BLOCK 7
a
INSTALLED NEW 1250 GAL HDPE SEPTIC TANK
CONNECTED TO DRAIN FIELD �\
INSTALLED NEW MONITORING TUBE & CLEANOUT T
LOT 8 /
^ B
,+ ouKM 1/
A
SFR l
LOT 7 /
ABANDONED EXIST/NG
SEPTIC TANK
DOUBLE
CLEAN
/ 4t FEET COVER
CONNECTED TO
EXIST DRAINFIELD
ANSON MOXNESS PE
2439 DOUGLAS DR
ANCHORAGE AK 99517
(907) 242 5995
1250 GALLON HDPE TANK
FOUNDATION
CLEANOUT
.:
49.th '';'
71 . - ...
' ..................
�n ..ANSON MfOXNESS s
►��5,':� NO, CE -103906
e;iFi►i►Sis►;.
BENCH MARK.- CONCRETE 0 BACK DOOR
ASSUMED ELEVATION 100 FEET
MCMAHON 12 BLK 7 LOT 7
HOWARD AND DEBRA GOLDEN
3741 TAIGA DR ANCHORAGE AK 99516
SEPTIC TANK ASBUILT
DA TE' OCT 5 2019
SHEET. 1/1 GRID: 2835
PERMIT #- OSPI91408 PID # 017-361-57 MCMAHON2B7L-4SB7,DWG
PER MOA
25 0 25 50 75 100 125 150
CODE REOU/REMENTS
SCALE, I' = 50 FT,
SWING TIES A B
NOTE.- THIS IS NOT A SURVEYED PLAT. VIELL & SEPTIC
S T. M.H. C
18.0'
21.0'
LOCATIONS TAKEN FROM ON-SITE WATER AND WASTE WATER
S T. C.O. D
DBL. C- 0- E
22.0'
25.5'
24.5'
27.0'
DEPART'VENT DOCUVENTATION. ALL LOCATIONS SHOWN ARE
APPROXIAfATE.
DOUBLE
CLEAN
/ 4t FEET COVER
CONNECTED TO
EXIST DRAINFIELD
ANSON MOXNESS PE
2439 DOUGLAS DR
ANCHORAGE AK 99517
(907) 242 5995
1250 GALLON HDPE TANK
FOUNDATION
CLEANOUT
.:
49.th '';'
71 . - ...
' ..................
�n ..ANSON MfOXNESS s
►��5,':� NO, CE -103906
e;iFi►i►Sis►;.
BENCH MARK.- CONCRETE 0 BACK DOOR
ASSUMED ELEVATION 100 FEET
MCMAHON 12 BLK 7 LOT 7
HOWARD AND DEBRA GOLDEN
3741 TAIGA DR ANCHORAGE AK 99516
SEPTIC TANK ASBUILT
DA TE' OCT 5 2019
SHEET. 1/1 GRID: 2835
PERMIT #- OSPI91408 PID # 017-361-57 MCMAHON2B7L-4SB7,DWG
Lot
8
X10
�70 �S9 000'
�fi�lL 001x, Lot 6
\F n- X06
r9
Wood & wire fence (typ) <
r --x 1-1 1-1
OM a.5 OIC deck
0 38.0
�j Manhole ti 2 Story Frame
o House o
CO N�23801 N
Op
pert 00)
Seg
Gacp°��
�
0 '59o0
0
i
n
r
69
Aj
\ ' qln
SCALE: 1 "= 40'
/fl �
1 a / Conc. block
ret. wall
N74 o
2001 /VV
10' x 20' Anchor
Easement
Chimney
ail
Gazebo & Spa
Well o
Lot 7
/ 8502Q
30
/
4,89 03 30
`33820 'l ��O
AS-Rttll T NO f:(1RNFRS SFT TUIQ MATH
®0N%XX1%
w�. OF • A4qsARW
f
49th •.-9
®
00 .
*
•••
01 i •. lizabeth L. Walatka ow
®�1P, • • 8036 - LS • • kl®
AW
aFESSIONAt•�®0
I hereby certify that I have performed a Mortgagee's inspection
in accordance with ASPLS Standards of the following
described property: LOT 7 BLOCK 7
SECOND ADDITION TO McMAHON SUBDIVISION
Anchorage Recording Precinct, Alaska, and that the
improvements situated thereon are within the property lines
and do not overlap or encroach on the property lying
adjacent thereto, that no improvements on the property lying
adjacent thereto encroach on the premises in question and
that there are no roadways, transmission lines or other
visible easements on said property except as indicated
hereon.
Dated at Anchorage, Alaska
this 14th day of JUNE 2022.
EASEMENTS OF RECORD, OTHER THAN iD' O ^ Z071
THOSE SHOWN ON THE RECORDED FRED WALATKA &ASSOCIATES, L.L.C.
PLAT ARE NOT SHOWN HEREONEngineers and Surveyors
BE
UNLESS OTHERWISE NOTED. FB 22-2, pg 22-25 907-248-1666.
This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary
survey and Is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to
establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original
client or by others at a later date without the consent of Elizabeth L. Walatka Is a violation of Federal Copyright law. Unless gross negligence is discovered,
the liability extent of the preparer is limited to the amount of fees collected for services In preparation of this product.
•
,4„.,,,'rMUNICIPALITY OF ANCHORAGE
• ,,,.,.__.....,,o, ^11,,Cnt
/ On-Site Water& Wastewater Program S
'; PO Box 196650 4700 Elmore Road _ f .
" Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 E.
r
http:/Iwww.muni.orglonsite r
� epartincnt
c NoRAO.
On-Site Wastewater Disposal System Permit
Permit Number: OSP191408 Effective Date: 9/13/2019
Work Type: SepticTank Upgrade Expiration Date: 9/12/2020
Tax Code Number: 01736157000
Site Legal Address: MCMAHON #2 BLK 7 LT 7 G:2835
Site Mailing Address: 3741 TAIGA DR, Anchorage
Owner: GOLDEN HOWARD & DEBRA Lot Size in Sq Ft: 25978
Design Engineer: MOXNESS ANSON Total Bedrooms: 3
This permit is for the construction of:
❑ Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: The septic tank shall be at least 5 ft from any carport supports.
:::::
By: Date:
: icuclLL'"�h"
( Date: I®!
MUNICIPALITY OF ANCHORAGE
® (
Development Services Department Phone: 907-343-7904
On-Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 061
Property owner(s) 1464, Day phone 21
Mailing address 37k ,cA.A. *C H -h-/ck '? I L
Site address S A i t e •
Legal description (Sub'd., Block & Lot) AcMatit,tJ x12 3 2---
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(® all that apply)
Absorption Field ❑ Initial ❑ Single Family (SF) 12'
(w/wo ADU)
Septic Tank Upgrade Duplex (D) ❑
Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
•
( •na ure of prope 'y owner or authorized agent)
Permit/Rush Fees: ORS CO Waiver Fees:
Date of Payment: VW 2447 Date of Payment:
Receipt Number: 02545 ✓ Receipt Number:
Permit No. Os Ptql462 Waiver No.
G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Appiication.doc
Anson Moxness, PE
2439 Douglas Dr
Anchorage, AK 99517
September 10, 2019
Municipality of Anchorage
Development Services Department
Building Services Division
On-Site Water and Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: SEPTIC TANK PERMIT APPLICATION
McMahon#2 Block 7 Lot 7
I am submitting an application to upgrade the septic tank for this lot.The existing septic tank serving the
above referenced lot has been compromised and the owner would like to replace it.The owners wish to
upsize to a 1250 gallon tank to replace the existing 1000 gallon tank.The submittal consists of one (1)
drawing showing the present improvements on the lot and the proposed improvements of the lot, of
which only the septic tank is subject to this permit application.
The installation of this septic tank will not prevent wells and septic systems from being installed on the
adjacent lots. There are no developed or natural surface/sub surface drainage courses within 100 feet
of the proposed septic tank location. The proposed septic tank will not change the general slope of the
area. Ponding and/or concentration of surface runoff will not result from this installation.
If you have any questions or are in need of additional information please contact me at 242-5995.
Sincerely,
/'
/ -_
'Anson Moxness, P.E.
2439 Douglas Dr, Anchorage, AK 99517
(907) 242-5995
anson.moxness@gmail.com
....'...\./
ip. LOT 6
� \ Grl �
Septics / \€N, MCMAHHN #2 S/D I
/ . \� . BLOCK 7 / /
/ /
INSTALL NEW 1250 GALLON HOPE SEPTIC TANK \ \7
CONNECT TO DRAIN FIELD ---
LOT 8 / I'
�---
/ 3 ORM / /
/ SFR /
•
.0401.
/ ,.
LOT 7
NOTE:ENSURE TANK IS LOACATED l I
>5' FROM CARPORT SUPPORTS & 1 -
>10' FROM FOUNDATION / I
\ Ili \ .---}
\ \ ABANDON EXISTING I
SEPTIC TANK PER MOA
m-m-.. ••• CODE REQUIREMENTS
25 0 25 50 75 100 125 150
SCALE: 1' = 50 FT.
NOTE: THIS IS NOT A SURVEYED PLAT. WELL & SEPTIC
LOCATIONS TAKEN FROM ON-SITE WATER AND WASTE WATER
DEPARTMENT DOCUMENTATION. ALL LOCATIONS SHOWN ARE
APPROXIMATE.
4 FEET COVER
DOUBLE
CLEANOUTS
NEry= ' FOUNDATION
_ I- ir4LE n=u=11=11=11:=II;II'-11="` CLEANOUT
11=11-11:-11=�I f=11==II-11=11=11=11=11=11=�'-
II II�I 11==I11:I 111 II 11=11 1111011'"11-11
-11=11-11=1=11=11=11—
IIJI II��.11:=�II?:I1—" E a = E 4 =
.WI�S`U\\��
OF 47
4*c
' 49th �\ •• #0
•
••,
CONNECT TO 1250 GALLON HDPE TANK • -1_---- / �
EXIST DRAINFIELD ♦ '; Y' • mils
ANSON♦ ANSO MOXNESS
.: 4/m
♦O- % No. CE-103906 • -\
.S‹eF •••••.,,e-1 /1 /7. <c, 4
•BENCH MARK • •
•'4-11'asw���0"4•'
ASSUMED ELEVATION 100 FEET
ANSON MOXNESS PE MCMAHON 12 ELK 7 LOT 7 ' SEPTIC TANK
2439 DOUGLAS DR
ANCHORAGE AK 99517 HOWARD AND DEBRA GOLDEN DATE: SEPT 11 2019
(907) 242 5995 3741 TAIGA DR ANCHORAGE AK 99516 SHEET: 1/1 GR/D: 2835
PERMIT #: OSP191408 PID # 017-361-57 MCMAHON2B7L 7 D WG
GRE,-,,ER ANCHORAGE AREA BOL .UGH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
NAME t~/'
LOCATION
INSPECTIONREPORT ON-SITE SEWAGE DISPOSALSYSTEM
L?r, LEGALDESCR,PT'ON ZOf 7 7
SEPTIC TANK:
DISTANCE / ~ ,~..~.~..,.~::..~/' NUMBER OF
INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH ../'~'~'LIQUID CAPACITYOOOALLON$.
TILE DRAI N~'FIELD:
/
D,STANCE FROM WELL/OD FOUNDAT,ON Z 7
NUMBER OF LINES 1 DISTANCE BETWEEN LINES
ABSORPTION AREA Z/ ~
DEPTH: TOP OF TILE TO FINISH GRADE
NEAREST LOT LINE 2S/oFTOTALLINEsLENGTH ,~::, f
P/~-~ TRENCH WIDTFL/~IN. TOTAL EFFECTIVE
SQ. FT. LENGTH OF EACH LINE / /~¢'~ ~ '¢~ ¢ /*
WELL:
CONSTRUCTION
BUILDING NEAREST NEAREST
FOUNDATION__ LOT LINE__ SEWER LINE__
SEPTIC
, TANK __
CESSPOOl
, OTHER SOURCES
APPROVED
DISAPPROVED
REMARKS
DEPTH
SEEPAGE
SYSTEM
DISTANCE FROM:
DISTANCES: ~/~"~"'"'~-
INSTALLED BY:
SEWER LINE DEPTH:
PIPE MATERIAL:
LOT SLOPE:
REMARKS:
?]AGRAM'OF SYSTEM
G .A .A. B:~./~
Form EQ-032
START
TIME
DRILL LOG CASING
C.U,
SELF' DRILLING
914 East 78th Avenue
ANCHORAGE, ALASKA
344-9242
COMPLETE
DATE
NAME tNo.
ADD?ESS __
CITY /PHONE
JOB LOCATION
TIME WELL LOG DEPTH WELL LOG
GPM - YIELD
STATIC LEVEL
PERMIT N0.
FIF'F'L I CRNT
L. OCRT I ON
LEGRL
W D ITTE:F.:ENt';,ER _,F..H E:FO.:: 476"r'
T FI I G R [:'R I V E
L7 87 MC:MFIHON SUBD RD[:'N ~2
LOT SIZE
:?.E)k-3E;8 SQURRE FEET
T"¢F'E OF c;, '- I L HB_,UF..BT I ON S"r'STEM I S: TRENCH
MRXIMI_IM NUMBER OF BE[:,ROOMS = S
SOiL RRTING (SQ FT,.-"BR)=
]"HE REQLIIRED SIZE OF THE SOIL IRBSORF'TION S'.r'STEM IS:
THE LENGTH DIMENSION IS ]"HE LENGTH (IN FEET) OF THE TRENCH OR [:,RRINFIEI..D.
'THE DEPTH OF R TRENCH OR PIT IS THE DIS'TFINCE BETWEEN THE SURFRCE OF THE
GROUND RND THE BOTTOH OF THE E'XCRVRTION (IN FEET).
]"HERE IS NO SET WIDTH FOR TRENCHES.
]'HE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRRVEL BETWEEN THE OUTFFIL.L F'IPE
FIND THE BOTTOM OF THE EXCR',,,'R]'ION (IN FEET).
~j P-~ _--_. F-.'. E Q L~ ~ EE:: LEE
'1- ~.~ C~ ,:." '::
][ t'-.i'_.~;F"EC:-F ]E -- "'-- RRE
BRCKFILL. ING OF RN'.¢ =,Cz, TEll NITHOLIT F!NRL INSF'ECTION RN[:, RPF'R]',,,'RL B"r' THIS
[:,EPRRTMENT WILL BE SIJBJECT TO PROSECUTION.
MINIMUM DISTRNCE BETWEEN R WELL RND RN'¢ ON-SITE SENRGE DISPOSFIL S~r'S'TEM IS
:1.0~ FEET' FOR R PRIVFITE WELL OR 2E~E~ FEET FOR R PUBLIC WELL.
WELL LOGS FIRE REQUIRED FIND MUST BE RETURNED "FO THE DEPRRTMENT WITHIN 3".E~ DR'CS
OF THE WELL COMPLETION.
SPECIFICRTIONS FIND CONSTRUCTION DIFIGRFIMS RF.'.E FI',/FIILFIBLE TO INSURE PROPER
INSTRLLRTION.
I CERTIF"¢ THRT
i;: I RM FRMILIRR 14ITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WEI_LS RS SET
FORT'H 8'¢ THE MUNICIPRLIT'¢ OF FINCHORRGE.
2: I WILL. INSTRLL THE S'¢STEM IN RCCORDRNCE WITH THE CODES.
Z::: I UNDERSTFIND THRT THE ON-SITE SEWER S'¢S]"EM i"IRM REQUIRE ENLRRGEMENT IF TNE
RESIDENCE IS REMODELED TO INCLUDE MORE THRN 3: BEDROOMS.
S I GNED ' _ ......................
RPPLICRNT W D I T TE, F..ENDEF..
_ _ ~ ..... DRTE ............................
, De~rtment of Health and Environment-~', Protection
A[tchorage, Alaska 99507
....... 2.- ~Z~II
.";()II,S 1,0(3 PIHI()I,ATION r|'I~S'I'
Performed fo~ ..... .~._.~_~r~_ .................................. ;~ate Pcrformu.J
Legal Uescrip~tion:
.form reports:
Dep th -
Feet
9-
'10 -
11
'Ce- ~ T F< c-:-~ D ~o ,b.
Was ground wa~er encountered?
If yes, a~ wna~ de,;th?
Reading Date Gross Time ' ~. 'F~et Time ' f Depth t°_~ate;~ Net i)ro!~::;~.,,,
CZ_ZZZZV. LT_-.'-_Z_-_-ZJ-:LL.Z '_ --~ ......... ' .......
,Proposed installa~'n-~-]"~b-eh~'ge Pit Drain Field
MUNICIPALITY OF ANCHORAGE
Q
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 017-361-57
1. GENERAL INFORMATION
Expiration Date: 1 9 r 2�
Complete legal description McMahon #2 Block 7 Lot 7
Location (site address) 3741 Taiga Dr Anchorage AK 99516
Current property owner(s) Debra and Howard Golden
Mailing address same
Real estate agent
Teresa Bell
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
Day phone 240-7612
Day phone 240-2248
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
0
Private Septic
❑
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ yy� Waiver Fee $
Date of Payment Date of Payment
Receipt Number / Receipt Number
COSA # 0 S C 22 1 3 Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm Anson Moxness, PE Phone 242-5995
Address 2439 Douglas Dr, Anchorage, AK 99517
Engineer's Printed Name Anson Moxness Date
• 7SY\"j4r(7-7e�
` 9t
6. DSD SIGNATURE r..... ... .......................
r
_)!C, System #1 Approved for bedrooms •..ANsaN MOXNESS••
No
System #2 Approved for bedrooms �� s` :,. . E-143906 : ti
�y
Disapproved ®��♦�.SP.
Conditional approval for bedrooms, with the following stipulations:
\PNLITY
0
�m
W ER v
��FRVI CES\������\
By: Original Certificate Date: C
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheat
Legal Description: McMahon #2 Block 7 Lot 7
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled 1977
Total depth 161 ft
Cased to 161 ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) 24 in.
Date of flow test for COSA 7112122
Static water level at beginning of test 160 ft.
Comments Well log unreadable, Well inspection previously filed
B. TANK DATA
Age of tank(s) 3 years
Tank type/material HDPE
Measured operating fluid level in septic tank 56
❑ Standpipes/foundation cleanout per record drawing
Date of pumping 8/2/22
A
D. ABSORPTION FIELD DATA
Which system tested (date installed) 8/3/22
❑ ALL standpipes present per record drawing
Total measured depth from grade 7 ft (max)
Measured depth to pipe invert from grade 4 ft (min)
❑ N/A m- pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
NO Code -required soil cover over field
Parcel ID: 017$361-57
Structure served by this system 1
Well production at time of test 10 gpm
Water storage tank volume gallons
Well disinfected for coliform test? ❑ Yes ❑ No
❑ Coliform bacteria is Negative
Nitrate 2• mg/L ❑ Nitrate less than MRL (ND)
Arsenic: ug/L ❑ Arsenic less than MRL (ND)
Collected by Anson Moxness
Date of Sample 7/13/22
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments:
Adequacy test date New
Results ❑Pass For bedrooms
Fluid depth prior to test in
Water added gal
New depth in
Elapsed time min
Final fluid depth in
❑ System presoaked Absorption rate gpd
(Required if vacant for greater than 34 days prior to Any rejuvenation treatment (past 12 months)
date of test) If yes, enter date
Gallons introduced gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
C]
Yes
Community Sewer Manhole/Cleanout > 100'
[J✓` Yes
if No
ft
M Yes
if No ft
Neighboring Tank > 100' Q✓ Yes
if Na
ft
Private Sewer/Septic Line > 25' El Yes
if No ft
Absorption Field on Lot > 100' E✓ Yes
if No
ft
Holding Tank > 100' 0 Yes
if No ft
Neighboring Absorption Fields > 100'
❑✓ Yes if No ft
Water Main > 10'
Animal Containment> 50' Q Yes
if No It
E] Yes
if No
It
Q Yes if No ft
Water Service Line > 10'
[✓
Yes
if No
Manure/Animal Excreta Storage > 100'
If septic tank is under driveway comment below
Community Sewer Main > 75' 0Yes
if No
ft
✓Q Yes
if Na ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
C]
Yes
if Na
ft
Surface Water> 100'
Yes if No ft
Property Line > 5'✓Q
Yes
Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
Q
Yes
if No
ft
Private Wells > 100'
❑✓ Yes if No ft
Water Main > 10'
Q
Yes
if No
ft
Community Wells > 200'
Q Yes if No ft
Water Service Line > 10'
[✓
Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
C]
Yes
if No
ft
if absorption field is under driveway comment below
Property Line > 10'
21
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'no'
Yes
if No
ft
Private Wells > 100' Yes if No ft
Water Service Line > 10'
Q
Yes
if No
ft
Community Wells > 200' Q Yes if No ft
Surface Water > 100'
Q
Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that / have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
Lot 8 Hca
�ro�s9-
00'
00', Lot 6
\\� 706
7
Wood & wire fence (typ) �f `g
W
.!Z?4.5 OH 38 EMT 0 eck
oQ) Manhole S 2 Story Frame
So House o
CO N `2 CD
38.01 NO
00 dk deck
\ geP�ic vent
00
1
Sig° a f Conc. block
rte• ret. wall
000'l,,
Stj Jf
rq,�q <.,89
4,Q7� 03
fi
,J.
SCALE: 1 "= 40`
N74ops
\
54.92
10' x 20' Anchor
Chimney Easement /
/ 8502Q
/ 30
41
O U
78.
Gazebo & Spa (V
O CC/ l
Well o
h
4
Lot 7 z
30
RECERTIFIED 8-04-22�
AS -BUILT NO CORNFRC SFT THTC nATF
®LXXX\ I t
of + A4qS ,l
00 _49th00
00
00
0 !V,,'. Izabeth • alatka
�� ���F • , 8036 - L5 . • AM
ttP
o i O pRaFESSIONA�
W
•\ym'
�
EASEMENTS OF RECORD, OTHER THAN�Zra
THOSE SHOWN ON THE RECORDED i G -
PLAT ARE NOT SHOWN HEREON FB 22-2, pg 58 BE
UNLESS OTHERWISE NOTED. FB 22-2, pg 22-25
I hereby certify that I have performed a Mortgagee's inspection
in accordance with ASPLS Standards of the following
described property: LOT 7 BLOCK 7
SECOND ADDITION TO McMAHON SUBDIVISION
Anchorage Recording Precinct, Alaska, and that the
improvements situated thereon are within the property lines
and do not overlap or encroach on the property lying
adjacent thereto, that no improvements on the property lying
adjacent thereto encroach on the premises in question and
that there are no roadways, transmission lines or other
visible easements on said property except as indicated
hereon.
Dated at Anchorage, Alaska
this 14th day of JUNE 2022.
FRED WALATKA & ASSOCIATES, L.L.C.
907-248-1666 Engineers and Surveyors
This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary
survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to
establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original
client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered,
the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product.
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
1. GENERAL INFORMATION
Complete.legal description
HAA #
Location (site address or directions)
Property owner
Mailing address
Lending agency
Mailing address '~t~o
Agent ~.~,¥ ~_~,- ~J
Address ¢-&,o O
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS:
Day phone .~ ¥~-- 5~,u-~
Day phone
Day phone
TYPE OF WATER SUPPLY:
Individual well
Community well
NOTE:
Public water
If community well system, provide written confirmation from State ADEC attest-
lng to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE:
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. 1/91) Front MOA #21
sluewwoo leUO!~!PP¥
:suo!~elndRs 15U!MOIIO~ egl~ LI~!M 'SLUOO~peq
]o~ leAo~dde leUO!l!puoo
'peAoJddes!Q
'SLUOO~peq
/& '&/./4 al. aa
.~o~. peAo.lddv ~,~
:II::IrlJ.'VN~DIS SHHa '9
e~n~eua!s s,~eeu!au3
/ -~z~ o/ sseJ ppv
I:EI:iNIgN:I A8 NOIIO:IdSNI -10 J.N:~:I.L¥1$
Legal Description:
A, WELL DATA
Well type ~
Log present (Y/N)
Total depth
Sanitary seal (Y/N)
Municipality of Anchorage '~,~,
Department of Health & Human Services
HEALTH AUTHORITy APPROVAL CHECKLIST '~c~,~;4,..,~.~
if A, B, or C, attach ADEC letter.
~ _/"~o-~'~ ~'-~.) Date completed
I (~ I Cased to I (~ !
1~I77 -~ Driller C.
Casing height
Wires properly protected (Y/N)
Date of test:
Static water level
Well flow
Pump level
FROM WELL LOG
AT INSPECTION
cia. ?/
g.p.m. ~' ' g.p.m,
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot //
Absorption field on lot /~
Public sewer main
Public sewer's~'rvice line
; On adjacent lots
; On adjacent lots
Public sewer manhole/cleanout ~//,Ar
Petroleum tank
WATER SAMPLE RESULTS:
Coliform
Date of sample:
Nitrate
~). ~ ~ Other bacteria
Collected by: ~--~' ----~- '
B. SEPTIC/I |CLD;;;G TANK DATA
Date installed
Cleanouts (Y/N)
High water alarm (Y/N)
Date of pumping
Tank size I0~o Compartments ~
Foundation Cleanout (Y/N) ~/ Depression (Y/N)
'/~//~ Alarm tested (Y/N) ' ~//~A,
SEPARATION DISTANCES FROM SEPTIC/HeEDING TANK TO:
Well(s) on lot //7
To property line '~
Surface water/drainage
On adjacent lots ~/OC~
AbSorption field / 7
Foundation
Water main/service line
72-0~6 (Rev. 3/91) Front MOA 21 CONTINUED ON BACK PAGE
C, LIFT STATION
Date installed
Size in gallons
Vent (Y/N) "Pump on" level at
High water alarm level
Meets MOA electrical codes (Y/N)
SEPARATION DISTANCE FROM LIFT STATION TO:
Manufacturer
Manhole/Access IY/N)
"Pump off" level at
Cycles tested
Well on lot
On adjacent lots
Surface water
D. ABSORPTION FIELD DATA
Date installed / ?77
Length ~ Width
Total absorption area ~, /
Depression over field (Y/N)
Results (pass/fail)
Peroxide treatment (past 12 months) (Y/N)
System type
Gravel thickness ~,, ' Total depth
Cleanouts present (Y/N) ~"
Date of adequacy test ~/¢~//?
for
J~/ If yes, give date
Soil rating I0o
bedrooms
SEPARATION DISTANCE. FROM ABSORPTION FIELD TO:
Wellon lot //'7/0'~-' On adjacent lots Prope(ty line ,~-~'
To building foundation ~--~ ~
, To existing or abandoned system on lot
On adjacent lots ~ ~ ~ Cutbank I'Y'//'A~, Water main/service line ~ -~--~
Driveway, parking/vehicle storage area
Surface water
Curtain drain
E. ENGINEER'S CERTIFICATION
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
. ~ ~ ,-~,;%¢¢~ ,,,,o.~..~., ~: ,..~. ~',tI .
HAA Fee $ /~ Waiver Fee: $
Date of Payment ~ ~ ~-~/ Date of Payment
Receipt Number ~ ~ ~ ¢ '-- ¢/¢~ Receipt Number
72-026 (Rev. 3/91) Back MOA 21
gSl L DiNDND BLVD.
~N~HOR~GE, ~L~SK~ ~02-~V04
(~07) 2~B-50V5
RESIDENTIAL WELL INSPECTION
LEGAL:
LOCATION:
OWNER:
L. ot 7.~ Block 7 McMAhor'~
3741 'f'ai
Cather'ine Hart
TYPE OF WELL: f::'rivat~ Single F:'amily
WELL LOG AVAILABLE: Yes
INSTALLATION REQUIREMENTS MET:Yes
WELL YIELD FROM WELL LOS: Ga].lons per Minute
PUMP YIELD FROM TEST:
6 Gal 101qS per Mi flute
DATE OF INSPECTION:
April 18,~ 1991
TEST PROCEDURE: Well was pumped at a constant rate while the
drawdown was moni tol'-ed wi th an acoustic
probe. A'k 'khe beg:Lnning o~~ the test water level was .~ound at 112
feet below top of casing. At a pumping rate o~: 6 gallons per
minute the water level dropped to 116 feet a~ter 8 minutes o4:
pumping. The water level stabilized at this depth and did not
change cluring the next 60 minutes c:)-~ pumping. The well recovered
1Cx}% in 2 minutes. A totai of 207 gallons were pumped.
TEST FOR E.COLI AND TOTAL NITROGEN: Water' was tested 'for' E.Coli
and total nitrogen on April 19,~ 1991.
E,Coli 0, Total Nitregen 0,68 rog/1,
Max, allowable T'otal Nitrogen 10 rog/1,
TEST RESULTS: This well meets the requir'ements c,.F the
M u.n i c: i p a 1 i 'k y c:,.F A n ,::: h,::)r a g e.
THIS WELL WILL PRODUCE MORE THAN ! ~ALLONS PER MINUTE FOR MORE
THAN FOUR HOURS
The Mur~ic:i. pal r'ectu:[remer~t .for well flow is 150 gallons o~: water
per bedroom per day. This well exceed this requirement. The
assessment of the cond:i, t i on of the we]. 1 app:l, i es on 1 y to t:he
c:onditions as o.f 'khe day testecJ, The .Flow rate may change due to
~SL.d:)sLlrfac:e CC)l"ldi'~:.ic)l-r&s tJ"iat: tn~y I"tlD~] be ebfise:,Fvec:J t:l"C:)m '[7. he
and changes in the lafld LH~;~)~ al"HJ other fac:'kors 'khai: may impact: the
acluieer' .feecting t. he well,
6751 ~, ~IHDN~ BLV~,
~NCHOR~BE~ ALASKA 99502-3~0~
(907) 26B-5095
LEGAL:
LOCATION:
OWNER:
RESIDENCE:
WELL:
SEPTIC SYSTEM:
SEPTIC SYSTEM ADEQUACY TEST
[]att her' J. i']e Hart ~,~ ,. '
. ' ~,
S:i. nqle f:'amiI , ~ 3 Bedrooms ' ~"
F'ROM MI.JNICtF'AL. RE[lORDS: 3 Bedroom System
TANK: Greet Steel 1OOO Gal. 'T],¥o Compar't,s.
Ai}:{SORPT I ON SYSTEM: "French
ABSORF:'TZON AREA: 312 Sq. F:t.
SO ]: L RA]" I NG: 10C)
I NSTAL..L.A]" I ON DATE: 1977
DATE OF LAST PUMPING: A+ Home ~',.~','~,,'', .[c'-~=~... Jan/Feb 1991
DATE OF TEST: Apr':[1 ].8~ :[99:1.
TEST PROCEDURE: Sys'Eem was inspected and measured. '/"ank was
.Found with 3 ~eet o~ cover and with a liquid level e,F 48.5 inch-
es. Trench c:lean out was deep and dry. Trench mor~itc)r tube was
6 .Feet deep with 12 inches of water.
72C) gallons e.F clean water was added i:o the trench while ~l")e
water lev(.:~,!s il"~ the tank al'id the filC)l]it(]r tt.~be ~,.Jere mc)nitored. ]"he
~,a't:,er l~ve]. :i.n the '~:al]k did l]ot c:hange~ v~h:[].e the ].evel in i:'.he
m(]nit(:)r rose 30 :i. nches.. The next day the vaai:er level in the
monitor tube was c:hecked. The water lew:,z, 1 had dropped 27 inc:hes~
:i. rldicatin(:~ thai: 650 gal l(:)ns ~4:: water had heel'1
TEST RESULT: 'l"h:i.s ....... t.,..m meets the code?
the Health and
Depal."'tment e~: thce Munic:ipa].ity c, 4: Anc:hc) r'age.
r eqL.ti r emel"Y~.s o4:
S o c i a I S e r v i (:: e s
NOTE The operational l:[,z.e <:)~ all sep'Lic systems depends [)n 'the
:[ (3C:~.], S(:)i I (::(3rid i t i c3r]s ~ (.:jrc)ur')dv~a'L:er 1 eve]. s tha't: may ~: 1 uctuate
clur:i.r)g the year"~ and the wa'l:er usage o~ t. he eamily be:Lng served
by the system,, These c:(:~nditi(:)ns are outside the contrc:~Z o~: the
eMa].L[atc)r o~ th:[E; sep~.~(: ~;F. yste[[~. [~]e (::ar'~ there.Fete riot c~]:i, ve any
esi:imai:e o~: how lon(:j tl'l:Ls system
/~~--~ ~, MUNICIP~TY OF ANCHORAGe..
~o'~,~ . - DEPARTM? ~ O.F/~A~L'[/I-J~IDfENVIRONME~~ '),L PROTECTION
~1: Time~ fl:00 a.m._~~ Time ~3: Time
Date 7-14-77 Thursday Date Date
Insp ~chhc!z /~~ Insp Insp
REQUEST FOR APPROVAL ~F INDIVIDUAL SEWER AND WATER FACILITIES
Lending Institution Request: Alaska Bank of Commerce
Mailing Address: Pouch 7-012 99510 Phone: 279-5641/350
Property Owner: Wilber W./Gloria Dittbrender
Mailing Address:
3. Legal Description: Lot 7 Block 7 Mc Mahon Subdivision
4:
Phone: 349-2235
Single Family Residence: (x)
Multiple Family Residence: ( )
Number of Bedrooms: One
Number of Bedrooms:
Well System:
Permit #
Construction
Individual Well (x) Community/Public System ( )
Depth of Well Well Log on File ( )
Bacterial Analysis
Sewage Disposal System:
Permit #
Septic Tank Size
Absorption Area
On-site System (x) Public Utility ( )
Installed 1977 Installer.
Manufacturer
Soils Rate Material
Distances: Well to Septic Tank to Absorption Area
to Sewer Line Nearest Lot line Absorption Area
to Nearest Lot Line
Pag~ Two
Department of Health and Environmental Protection
Request for Approval of Individual Sewer and Water Facilities
Legal Description: Lot 7 Block 7 Mc Mahon Subdivision
Comments:
Affadavit Attached: ( ) Letter Attached: ( )
Approved: ~.~~~_t Date:
Disapproved: Date:
Department Worksheet:
...... MUNICIPALITY OF ANCHORAG
~/~..~.'~2.~ -, ~ Departmenh of Health and Envlronmenta± Prot~:~.lo:n
"[/~'~"~i~:'"~"i; 825 L Street, Anchorage, Alaska
~ ~'""~/~ 27~-2511, e..t. 224, 225
"
z~<-m:'f~-%~&quest for Approval of Zndividual Sewer aha Water Facili%ies [~
1. 2~ope~ty Owne~: Nilber N. & Gloria Dittrend~
NaiIing ~ddress: Star Route Taiga Dr. Phone:
N~me of Buyer:
Mailing Address:
Marshall & Kathryne A. Har~e
SRA Box 1670 Anch. Phone: 349-1173
Lending Institution:
Mailing Address:
Alaska Bank of Commerce
Pouch 7012 Anchorage, Ak.
9951-Y --
Mary Lou Cacy
Realtor/Agent:
Mailing Address: 2804 W. Northern Lights
Pholle:
279-56~1, x350
Phone: 277-3511
Legal Description: Lot 7, Block 7, McMahon S/D #2
Street Location: NHN Taiga Dr. Anchorage, Ak.
Single Family Residence: (X) Number of Bedrooms:
Multiple Family Residence: ( ) Number of Bedrooms:
Water Supply: *Individua'l Well (X)
If Individual Well, well depth
If Co~mmmity System, name of system
Public/Community System ( )
8. Sewage Disposal System: On-site System (X) Public System
If On-site Syshen, date of installation:
*NOTE: A well log is required on ALI, wells drilled since 6/75.
3/7'/