HomeMy WebLinkAboutMARIANN Lot 73A & 73B S-7725 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION Environmental Health Division CASE REVIEW WORKSHEET CASE NUMBER: DATE RECEIVED: S-7725 June 12, 1984 SUBDIVISION OR PROJECT TITLE: Lots ~3A, ~Mariann Subdivision ( ~J[~/PUBLIC WATER AVAILABLE (~) COMMUNITY WATER AVAILABLE /PUBLICSEWER COMMENTS DUE BY: June 29, 1984 AVAILABLE 71-014 (Rev. 5/83) DISTANCE TO: ~".' MUNICIPALITY OF ANCHORAGE C DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT PHONE ANEw Inside length IF HOMEMADE: Dwelling DISTANCE TO: Manufacturer DISTANCE TO: No. of lines J Top of tile Length Type of crib DISTANCE TO: DISTANCE TO: Fou ndat ion,.- ,~- *~ Width Depth NO. OF BEDROOMS Dwelling ~ /.1/- PE~T Wi~d t h~ No. of compart~n{s ~ ' ~ Liquid depth PERMIT NO. Material ............. L~quid Capacity in ~llons i Z / ~ Total effectiv~absorption area inches PERMIT NO. Crib depth Total effective absorption area Well Building foundation Nearest lot Jine Driller Distance to lot line PERMIT NO. Septic tank Absorption area(s) Building foundation Sewer line OTHER MATERIALS ~EMARKS /. /?~)l:l(Rev. 3/78) DATE LEGAL ~ E, ~ E:]GINEP-i~ING · . SRB 196~ -- ,~ STATE OF ALASKA k-¢~1-~ ~)' DEPARTMENT OF ENVIRONMENTAL CONSERVATIONS) APPROVAL OF ON-SITE RESIDENTIAL WATER AND SEWER SYSTEMS PROPERTY DESCRIPTION ILot, Block & Subdivision or U.S. Survey The Department of Environmental Conservation does not guarantee the continued satisfactory'perform- ance of the water supply and wastewater disposal systems. The validation dates are based on evaluation of the systems using accepted engineering practices and assuming satisfactory maintenance. WATER SUPPLY w m:has been evaluated and .found to comPly with 18AAC 8.0,~tandards for ater quality of Class~ water supplies a~ separation distances as appropriate. ~,i.,~""~- Th'~r _~¢ff~nths for t~upply System from date of issuance, pro- WASTEWATER DISPOSAL The domestic wastewater treatment and disposal system has been evaluated and has been found to be in compliance with 18 AAC 72 for a [] single family J~nulti-family unit with. ~ total bedrooms, satisfying the requirements for design, sizing and construction of a wastewater disposal system. · ~/~ months for the Wastewater ,Disposal System from date of is- This certificate is valid for suance, provided the system is properlyZ maintained. Receipts for Septic Tank Pumping, which is required every 24 months, must be retained for a valid approval. 18-0Z~04(6/82) Distribution: White -Bank/Lending Institution; Canary - Applicant; Pink - Department BILL SHEFFIELD, GOVERNOR DEPT. Ot ANCHORAGE/WESTERN DISTRICT OFFICE 437 "E" STREET, SUITE 303 ANCHORAGE, ALASKA 99501 July 30, 1985 S & S Engineering SRB 196X Eagle River, Alaska 99577 SUBJECT: Lot 73-B; Section 5; T15N; RiW; Eagle River, Alaska 8621-FA-022 and 8621-DA.-032 274-2533 Dear Sir: We have reviewed the plans and specifications for the subject project and are hereby issuing this approval letter which constitutes the permit required by A.S. 46.03.720(a) for construction of the sewer system and operation for the water system. Enclosed with this letter is a "Certificate To Operate" for the drink- ing water system° It should be remembered that final approval will necessitate the submis- sion of Engineer As-Built Plans and owners name, address and telephone number. This will consequently mandate that a professional engineer conduct basic inspection of this project so as to be able to sign off on as-built plans. Arrangement for this inspection work is the responsi- bility of the developer. Any future expansion of subject project will require additional approval from this office. Si ncerely, Steve W. En§, P.Eo District Engineer SWE/dd ENCLOSURE STATE OF ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION CONSTRUCTION AND OPERATION C'ERT FICATE for PUBLIC WATER SYSTEMS APPROVAL TO CONSTRUCT Plans for the construction or modification of in by public water system located , Alaska, submitted in accordance with 18 AAC 80.100 have been reviewed and are [] approved. <' [] conditionally approved (see attached conditions). BY TITLE DATE If construction has not started within two years of the approval date,.this certificate is void and new plans and specifications must be submitted for review and approval before construction. APPROVED CHANGE ORDERS Charlge (contract order no. or descriptive reference) Approved by Date APPROVAL TO OPERATE The "APPROVA.L..~T.~O .~. PER~,~E" 'Section must be completed and signed by the "~Dep~'~-~m~ent-b~ore any water is made av~ble to the public.~o~ ~/~(~ ~ ~ ~7~/ ..... The construction of the - ' ,~ ~ ~ · .~'?~ ~ ~ · i~ ' .'- ; · ~ ~.. ~ ~- public ~(dr system was completed on (date). The system is~ereby graY,ted interim approval to operate for 90 days following the completion date. aY ~iTL~ DAT~ As-built plans submitted during the interim approval period, or an inspection by the Department, has confirmed the system was constructed according to the approved plans. The system Is hereby granted final approval to. operate. BY TIT~E 18-0407 (Rev. 11183) DISTRIBUTION: 1. WHITE - ENGINEER (Complete Section C) 2. YELLOW - WATER SYSTEM FILE (Complete Section C) 3. PINK - ENGINEER/MUNI-BOROUGH (Complete Section C) 4. GOLOENROD - MUNI-SOROUGH (Complete Section A) :"~" *'~ : '"-~ STA'TE OF ALASKA D ~~ APPROVAL OF ON-SITE RESIDENTIAL WATER AND SEWER SYSTEMS PROPERTY DESCRIPTION Lot, Block & Subdivision or U,S. Survey The Department of Environmental Conservation does not guarantee the continued satisfactory perform- ance of the water supply and wastewater disposal systems. The validation dates are based on evaluation of the systems using accepted engineering practices and assuming satisfactory maintenance. WATER SUPPLY ----T~.a~,~s. tem has been evaluated and found to comply with 18 AAC 80, satisfy!n.~g.~tandards for system constr~ water quality of Class"{: water supplies and. f~G~aration distances as appropriate. This approval is valid for ...~:.~.~m~t~ t'~T~'e-~,.E~pply System from date of issuance, pro- vided the syst~y.j::~a~tained. ~ ' WASTEWATER DISPOSAL The domestic wastewater treatment and disposal system has been evaluated and has been found to be in compliance wi,th 18 AAC 72 for a [] single family J~ulti-family unit with ~ total bedrooms, satisfying the requirements for design, sizing and construction of a wastewater disposal system. This certificate is valid for ~7/4~ months for the Wastewater ,Disposal System from date of is- suance, provided the system is properly maintained. Receipts for Septic Tank Pumping, which is required every 24 months, must be retained for a valid approval. 18-0404(6/82) Distribution: White-Bank/Lending Institution; Canary -Applicant; Pink - Department