On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 1
ON -SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP221371 PID Number: 02009229000
Dwelling: 01 Single Family (SF) El with ADU R Duplex (D) R Two Single Family Project: OR New RN Upgrade
Name
Donna J. Platt (MF 11 Dec'24)
ABSORPTION FIELD
F1 Deep Trench R Wide Trench RN Bed R Mound
Site Address
16910 Bettijean Street, Anchorage, AK 99516
El Other
Phone
I Number of Bedrooms
Soil Rating
depth from original grade
907-346-3395 (MF 11 Dec'24)13
0.8 GPD/SF
ITotal
3.75' or less to rock Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Average 2' Ft.
Gravel depth beneath pipe
0.5+ Ft.
Subdivision Block Lot
Loma Estates 1 1
Fill added above original grade
—1 1 Ft.
Gravel length
24 Ft.
Township Range Section
Gravel width
r Ft.
Beds: Number of Lines
4
Distance between lines
6 Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
1576 Ft2
NA
NA F L
Well
>100'
>100'
>1 00'
-
>50'
TANK El septic 9 S.T.E.P. El Holding E] Other
Manufacturer
Anchorage Tank
Capacity
1500 Gal.
Surface Water
>100'
>100'
>1 00'
-
Material
Epoxy Coated Steel
Number of compartments
2
I
NA
Lot Line
>20'
>20'
>20'
-
Foundation
>1 0,
>1 0,
>1 0,
-
KIFT STATION
IManufacturer
Capacity
Gal.
Remarks As -built survey attached with exact measurements.
Alarm location
Electrical installed by
On House
JR. The Alaskan Electricians
Tank to ,
PIPE MATERIAL House to tank 4"ABSI�R_1411. 2 PVC
Installer
CIC General
drainfield
Drainfield 2" PVC CO/MT ABS/Fy
BENCH MARK (Assumed elevation) ft
inspector ANTHC / HDL Engineering Consultants
Inspection Is' May 11, 2023 Aug 22, 2023
Location and description
dates: 2 �d
3,dA u g 2 4;,,�", 4 1h S e p 8, fl`
ON -SITE WATER AND WASTEWATER SECTION APPROVAL
; 01F At,,q
Conditional Approval: Date
y.
00-4:*49 TH
0 ..........
.............
va* For4m 11
19 Dec 2023
Septic System
Approved Date 'ZVL,�-
DSW 4-
No CE 1166793
ITA,
Illk �K
Note: this ap i val does not include well permit requirements.
pf)o
Rev 05/02/18)
n
C
C
0
FIN
SITE PLAN
1 00'WELL
RADIUS
BLOCK 3
PLAT 76-262
/L=61.24', R=60.86'
A=057°39'17"
01 �J _
CELTIC DRIVE
w
�1 \
L=31.41', R=20.00'
tA=089'58'58"
T I
I
I
I
I
rl
I I
1. FIELD AS -BUILT SURVEY PERFORMED SEPTEMBER 13, 2023.
2. ALL DIMENSIONS SHOWN ARE IN US SURVEY FEET.
3. THIS DRAWING REPRESENTS AN AS -BUILT SURVEY OF
PLANIMETRIC FEATURES AND GROUND CONDITIONS AS THEY
EXISTED ON SEPTEMBER 13, 2023.
4. A TITLE REPORT WAS NOT PERFORMED, EASEMENTS OF RECORD
OTHER THAN THOSE SHOWN ON THE PLAT OF RECORD MAY
EXIST.
5. ADDITIONAL UNDERGROUND UTILITIES MAY EXIST THAT ARE NOT
SHOWN ON THIS AS -BUILT SURVEY.
6. STRUCTURE LOCATIONS FROM MUNICIPALITY OF ANCHORAGE
RECORD FILE #020-92-28 FOR LOT 2, BLOCK 1; #020-92-25 FOR LOT
3, BLOCK 1, #020-092-24 FOR LOT 4, BLOCK 1; #020-92-30 FOR LOT
1, BLOCK 3, #020-92-31 FOR LOT 2, BLOCK 3, #020-92-35 FOR LOT 9,
BLOCK 3, PLAT 76-262.
HORIZONTAL CONTROL STATEMENT
THIS PROJECT IS LOCATED ENTIRELY WITHIN THE ALASKA STATE
PLANE ZONE (AKSPZ) 4, U.S. SURVEY FOOT COORDINATE SYSTEM.
HORIZONTAL CONTROL
THE BASIS OF HORIZONTAL CONTROL IS ANTHC POINT #401, A SET
MAGNETIC NAIL LOCATED IN THE DRIVEWAY OF LOT 1, BLOCK 1, LOMA
HILLS ESTATE.
SAID STATION HAS AN AKSPZ4 US SURVEY FOOT VALUE OF:
N: 2582140.085'
E: 1679051.081'
Division of Environmental
Health and Engineering
4500 Diplomacy Drive
Anchorage, Alaska 99508
(907) 729-3600
0 F %�11
1�
Aw
00 ...................................�
P` PA.. / RUSSELL • ••••/
,�%••, LS-14430 •�.' �c�i
���t�� •� 1/2/2025 5
AW
,� 11 `SS I ON _ ���
�x
0 1.,
BAR IS ONE INCH ON
ORIGINAL DRAWING, IF NOT
ADJUST SCALES ACCORDINGLY
�; hJ w I VERTICAL CONTROL STATEMENT
(IV c0 v z o(~ THE BASIS OF VERTICAL CONTROL IS THE DERIVED NAVD88
�o o a w �' I ORTHOMETRIC HEIGHT OF ANTHC POINT 401, A SET MAGNETIC NAIL
/ O 0 Q I SET IN THE DRIVEWAY OF LOT 1, BLOCK 1, PLAT 76-262. SAID STATION Q LJ.I
� m I HAS COMPUTED ORTHOMETRIC HEIGHT OF 649.34 . H
GARAGE SLAB 80 W J
FF = 645.7' C) LEGEND 0 Q a
BASEMENT
F639.7' �`� „ I PC FOUND 5/8 " REBAR WITH PLASTIC CAP cc Q
G F 55.2' I OwZ
F w FOUND IRON PIPE _
OT 9-4F oM FOUND 5/8 " REBAR () H Q
Z Uo — — PROPERTY LINE Q
v ) I — —
LOT 1 BLK 1 J . EASEMENTw
014 PLAT 76-262 Co w
l ��
�" J' ANCHORAGE R.D. ST �_ � I EM ELECTRIC METER
CO
1.45 AC ST o I T z E GUY ANCHOR
i OR 63,302 SF c Q OH/E OVERHEAD POWER LINE
)� � z -' w
/ ;c+�j w I POWER POLE
0") ( O w m I CO SEPTIC CLEANOUT
J�
186.0' w ss SEPTIC SEWER SERVICE
SEPTIC TANK
/ J O QV SEPTIC VENT
C
/ J 641.6' I WS WATER SERVICE
WATER WELL
/ n• I Opp x x FENCE LINE
RIDGE R
`GQ� h� J• J' „ I STONE TREE LINE
't 624.1' I 800.0 SPOT ELEVATION
�3J NATURAL DRAINAGE
NATURAL GAS METER
F F UG NATURAL GAS LINE
PC — — — — — S89049'21 "W In 288.31' — — — —
'� TP TELEPHONE PEDESTAL
LOT 3 - UNDEVELOPED
PLAN SET: AKA-21-ANC
BLOCK 1
PLAT 76-262 I I CERTIFICATE OF SURVEY
I PROJ MGR:
LOT 2 I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING PROJ ENG:
/ DESCRIBED PROPERTY: LOT 1, BLOCK 1, LOMA ESTATE SUBDIVISION, TUS ENG:
PLAT 76-262, ANCHORAGE RECORDING DISTRICT, ALASKA, FOR THE DRAWN BY: PDR
J'J J
PURPOSES OF PROVIDING AN MOA COMPLIANT AS -BUILT. THIS SHEET TITLE
IJ I I SURVEY IS UNSUITABLE FOR OTHER USES. IT IS THE RESPONSIBILITY
I I OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, DONNA PLATT
I COVENANTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON THE
I / RECORD SUBDIVISION PLAT. AS BUILT
z
z
0
a
U
co
w
0
w
Q
0
11
SURVEY AS -BUILT
SHEET 1 OF 1
1 OF 1 TOTAL SHEETS
1"=30'
USER: PDRUSSELL PRODUCT: Autodesk Civil 3D 2023 - English FILE: \\deh02\Engineering\Anchorage\ANC_Survey\ANC_DATABASE\ANC_SURVEYS\ANC_SCATTERED_SITES\2023\Platt_Donna_As_Built_(2021_Site)\SRVY_DWG\ANC-V-XPBASE-DPlatt. dwg
LAYOUT: LAYOUT1 PRINTED: 1/2/2025 2:17:26 PM
MAT-SUANCHORAGE
907.564.2120
3335 Arctic Boulevard, Suite 100 Anchorage, AK 99503
907.746.5230
civil - geotechnical - surveying - environmental - material testing
www.HDLalaska.comAECL861
4500 Diplomacy Drive
4500 Diplomacy Drive
x
x
x
x
x
x
x
x
x
x
x
4500 Diplomacy Drive
4500 Diplomacy Drive
TH
TH
TH
4500 Diplomacy Drive
ϰϱϬϬŝƉůŽŵĂĐLJƌŝǀĞ
x
x
EG
:
6
4
3
.
8
'
EG
:
6
4
4
.
1
'
EG
:
6
4
3
.
3
'
EG
:
6
3
9
.
2
'
EG
:
6
3
8
.
3
'
EG
:
6
3
8
.
0
'
EG
:
6
3
7
.
0
'
EG
:
6
3
6
.
7
'
EG
:
6
3
6
.
9
'
EG
:
6
3
7
.
3
'
EG
:
6
3
8
.
0
'
4500 Diplomacy Drive
x
x
x
x
4500 Diplomacy Drive
x
x
4500 Diplomacy Drive
x
x
x
2'-0"
4' MIN
FINISH
FLOOR
WALL
FERNCO CAP
4" PVC
SCH 80
RISER
90° FITTING (TYP)
2% SLOPE MIN
TO SEPTIC TANK
OR SEWER MAIN
EXISTING
GROUND
CRAWLSPACE
4" PVC SCH 40 THROUGH
STEM-WALL PENETRATION
RUN SEWER SERVICE
LINE UNDER FOUNDATION
WALL AND FOOTER
USE ARCTIC BOX IF
SEWER CONNECTION
IS ABOVE GRADE
HOUSE
CONCRETE BLOCK
5'-0" MAX
RIGID
INSULATION
PVC SANITARY WYE
SEE SEWER SERVICE
TRENCH DETAILS
FOR BEDDING AND
BACKFILL REQUIREMENTS
HAZARD
TAPE6"
1'-0"
STUB OUT
1' MIN
ABOVE GRADE
CLEANOUT CAP, SECURE
WITH ALL METAL HOSE
CLAMP (FERNCO QWIK
CAP OR APPROVED EQUAL)
CRAWL
SPACE
WIDTH
VARIES
CONCRETE
STEM WALL
PENETRATION NOTE:
LOCATION OF PENETRATION SHALL BE APPROVED BY HOME OWNER
AND FIELD VERIFIED TO ENSURE PROPER LOCATION. PENETRATION TO
BE CLEANLY CORED OR DRILLED.
ELASTOMERIC SEAL
ELEMENT LS MODEL
(C, L, S-316,
O, OS-316, T)
(LINK SEAL)
LINK SEAL W/ BOLTS
CAST/CORE
DRILLED HOLE
SPRAYED
LOW-EXPANDING
URETHANE
INSULATION
INSULATE
WITH
SPRAYED
URETHANE
INSULATION
BITUTHANE SHEET
COVED AROUND
PIPE, SEAL WITH
BITUTHANE MASTIC
SPRAYED
LOW-EXPANDING
URETHANE
INSULATION
1/2" PLYWOOD
CRAWL
SPACE
TO SEPTIC TANK
OR SEWER MAIN
WOOD PENETRATION
1" = 4'
CONCRETE PENETRATION
1" = 4'
SEWER SERVICE - ABS PIPING
1" = 1'-0"
SHEET OF
4500 Diplomacy Drive
Anchorage, Alaska 99508
(907) 729-3600
D
A
B
C
12 3 4
Division of Environmental
Health and Engineering
BAR IS ONE INCH ON
ORIGINAL DRAWING, IF NOT
ADJUST SCALES ACCORDINGLY
USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2021 - English FILE: P:\_Eng_Ref\z_Restricted_Access\_Scattered_Sites_Library\SSD-C-DTSSWR.dwg LAYOUT: SSSD-301 SEWER SERVICE AND CLEANOUT - ABS PIPE PRINTED: 7/20/2022 3:05:52 PM
0 1"
TH
E
R
E
G
I
S
T
E
R
E
D
E
N
G
I
N
E
E
R
F
O
R
T
H
E
P
R
O
J
E
C
T
I
S
RE
S
P
O
N
S
I
B
L
E
F
O
R
T
H
E
P
R
O
P
E
R
A
P
P
L
I
C
A
T
I
O
N
A
N
D
IN
T
E
G
R
A
T
I
O
N
O
F
T
H
E
S
E
D
E
T
A
I
L
S
A
N
D
A
N
Y
M
O
D
I
F
I
C
A
T
I
O
N
S
SH
O
W
N
.
T
H
E
A
L
A
S
K
A
N
A
T
I
V
E
T
R
I
B
A
L
H
E
A
L
T
H
C
O
N
S
O
R
T
I
U
M
(A
N
T
H
C
)
O
R
I
T
S
A
G
E
N
T
S
O
R
E
M
P
L
O
Y
E
E
S
S
H
A
L
L
N
O
T
B
E
H
E
L
D
RE
S
P
O
N
S
I
B
L
E
F
O
R
T
H
E
A
C
C
U
R
A
C
Y
O
R
C
O
M
P
L
E
T
E
N
E
S
S
O
F
SC
A
N
N
E
D
C
O
P
I
E
S
O
F
T
H
I
S
P
L
A
N
S
H
E
E
T
.
T
H
I
S
D
R
A
W
I
N
G
H
A
S
BE
E
N
P
R
E
P
A
R
E
D
B
Y
A
N
T
H
C
A
S
A
N
I
N
S
T
R
U
M
E
N
T
O
F
S
E
R
V
I
C
E
AN
D
S
H
A
L
L
R
E
M
A
I
N
T
H
E
P
R
O
P
E
R
T
Y
O
F
A
N
T
H
C
.
A
N
T
H
C
S
H
A
L
L
RE
T
A
I
N
A
L
L
C
O
M
M
O
N
L
A
W
,
S
T
A
T
U
T
O
R
Y
A
N
D
O
T
H
E
R
RE
S
E
R
V
E
D
R
I
G
H
T
S
,
I
N
C
L
U
D
I
N
G
C
O
P
Y
R
I
G
H
T
T
H
E
R
E
T
O
.
STANDARD
DETAIL
VERSION
SSSD-301
11
SE
W
E
R
S
E
R
V
I
C
E
A
N
D
C
L
E
A
N
O
U
T
-
AB
S
P
I
P
E
1.0
NOTE: SEE SSSD-400 FOR MINIMUM FROST PROTECTION REQUIREMENTS
NOTES:
1. SEE SPECIFICATION FOR ADDITONAL EARTHWORKS REQUIREMENTS.
2. SEE SPECIFICATION FOR SEEDING REQUIREMENTS.
3. 4" MIN GRAVEL LEVELING COURSE, COMPACTED, IN DRIVEWAYS AND
ROADWAYS ONLY.
4. 12" TOPSOIL OVER COMPACTED FILL, 12" OVER SURROUNDING GRADE,
RAKED SMOOTH, MOUNDED AND LANDSCAPED WITH GRADE AND
FERTILIZED, EXCEPT NEAR HOME. MOUND SHOULD SLOPE WATER AWAY
FROM HOME.
5. LIMITS OF EXCAVATION, TYP. MINIMUM SLOPE OR PROTECTIVE SYSTEM AS
REQUIRED BY OSHA - BASED ON SOIL TYPE AND CONDITIONS 1 1/2 :1
SHOWN FOR TYPE C SOILS FOR REFERENCE.
6" MIN
(TYP ALL SIDES)
4'-0" MIN
CLEAN
COMPACTED
BACKFILL
6" WIDE
HAZARD TAPE
3/4" MINUS GRAVEL OR SAND PIPE BEDDING,
SEE SPECIFICATIONS
NATIVE MATERIAL
2'-0"
ARCTIC PIPE, 4" x 12"
1.5
1
2"THICK x 24" WIDE BOARDSTOCK
1.5
1
4" PVC. SCH 40 PIPE OR 4" ABS PIPE
6" MIN
(TYP ALL SIDES)
4'-0" MIN
CLEAN
COMPACTED
BACKFILL
6" WIDE
HAZARD TAPE
3/4" MINUS GRAVEL OR SAND PIPE BEDDING,
SEE SPECIFICATIONS
NATIVE MATERIAL
2'-0"
1.5
1
1.5
1
OPTION 1:
EXISTING DRIVEWAY, SIDEWALK, OR PATHWAY
OPTION 2:
YARD AND NON-PAVED AREA
OPTION 1:
EXISTING DRIVEWAY, SIDEWALK, OR PATHWAY
OPTION 2:
YARD AND NON-PAVED AREA
SEWER TRENCH DETAIL - ABS OR PVC PIPE
3/4" = 1'-0"
SEWER TRENCH DETAIL - ARCTIC PIPE
3/4" = 1'-0"
6" MIN
6" MIN
4"
4500 Diplomacy Drive
Anchorage, Alaska 99508
(907) 729-3600
D
A
B
C
12 3 4
Division of Environmental
Health and Engineering
BAR IS ONE INCH ON
ORIGINAL DRAWING, IF NOT
ADJUST SCALES ACCORDINGLY
USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2021 - English FILE: P:\_Eng_Ref\z_Restricted_Access\_Scattered_Sites_Library\SSD-C-DTRNC.dwg LAYOUT: SSSD-400 SEWER SERVICE LINE TRENCH PRINTED: 7/20/2022 3:06:46 PM
0 1"
TH
E
R
E
G
I
S
T
E
R
E
D
E
N
G
I
N
E
E
R
F
O
R
T
H
E
P
R
O
J
E
C
T
I
S
RE
S
P
O
N
S
I
B
L
E
F
O
R
T
H
E
P
R
O
P
E
R
A
P
P
L
I
C
A
T
I
O
N
A
N
D
IN
T
E
G
R
A
T
I
O
N
O
F
T
H
E
S
E
D
E
T
A
I
L
S
A
N
D
A
N
Y
M
O
D
I
F
I
C
A
T
I
O
N
S
SH
O
W
N
.
T
H
E
A
L
A
S
K
A
N
A
T
I
V
E
T
R
I
B
A
L
H
E
A
L
T
H
C
O
N
S
O
R
T
I
U
M
(A
N
T
H
C
)
O
R
I
T
S
A
G
E
N
T
S
O
R
E
M
P
L
O
Y
E
E
S
S
H
A
L
L
N
O
T
B
E
H
E
L
D
RE
S
P
O
N
S
I
B
L
E
F
O
R
T
H
E
A
C
C
U
R
A
C
Y
O
R
C
O
M
P
L
E
T
E
N
E
S
S
O
F
SC
A
N
N
E
D
C
O
P
I
E
S
O
F
T
H
I
S
P
L
A
N
S
H
E
E
T
.
T
H
I
S
D
R
A
W
I
N
G
H
A
S
BE
E
N
P
R
E
P
A
R
E
D
B
Y
A
N
T
H
C
A
S
A
N
I
N
S
T
R
U
M
E
N
T
O
F
S
E
R
V
I
C
E
AN
D
S
H
A
L
L
R
E
M
A
I
N
T
H
E
P
R
O
P
E
R
T
Y
O
F
A
N
T
H
C
.
A
N
T
H
C
S
H
A
L
L
RE
T
A
I
N
A
L
L
C
O
M
M
O
N
L
A
W
,
S
T
A
T
U
T
O
R
Y
A
N
D
O
T
H
E
R
RE
S
E
R
V
E
D
R
I
G
H
T
S
,
I
N
C
L
U
D
I
N
G
C
O
P
Y
R
I
G
H
T
T
H
E
R
E
T
O
.
STANDARD
DETAIL
VERSION
SSSD-400
11
SE
W
E
R
S
E
R
V
I
C
E
L
I
N
E
T
R
E
N
C
H
1.0
FOR BUILDING SEWER LINE
2" SCH 40 PVC PIPE FOR PRESSURIZED SEWER LINE
PRESSURIZED SEWER LINE TO SLOPE BACK TO TANK
MIN 2' OF SOIL COVER AND 2" OF INSULATION FOR FROST PROTECTION
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP221371
Work Type: Septic Upgrade
Tax Code Number: 02009229000
Site Legal Address: LOMA ESTATES BLK 1 LT 1 G:3337
Site Mailing Address: 16910 BETTIJEAN ST, Anchorage
Owner: PLATT DONNA J &
Design Engineer: HDL ENGINEERING CONSULTANTS
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
i
1Jeparnnent
12/16/2022
12/16/2023
63302
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Gtr
CD (�Orv°T G -D �-
Received By: S SoliQ TD 14- Q L
Issued By:
-- I i- Or
C /I
Date:
Date: I 2 Z,-.) Z Z_
9
\JIIUNCFPAUTY OF AHCHORAGIE
Development Services Department `''
p p - -� Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 02009229000
Property owner(s) Donna J. Platt
Mailing address 16910 Bettijean Street, Anchorage, AK 99516
Site address 16910 Bettijean Street, Anchorage, AK 99516
Day phone 907-346-3395
Legal description (Sub'd., Block & Lot) Loma Estates Subdivison, Block 1, Lot 1 (Plat: 76-262)
Legal description (Township, Range & Section) Seward Meridian, T.11 N, R.3W, SE 1/4 SEC 3
Lot Size 63,302 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field 0 Initial ❑
Single Family (SF) ❑
Septic Tank ElUpgrade N
(w/wo AD U)
Holding Tank ElRenewal ElDuplex
(D) ❑
Privy ❑
Multiple Dwellings ❑
(SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that
this is in accordance with
applicable Municipal Codes.
k__�
Chris Bowman, PE
(Signature of property owner or authorized agent)
Permit/Rush Fees: 515 Waiver Fees:
Date of Payment: 1015b2- CJti, Date of Payment:
Receipt Number: Oas5l� Receipt Number:
Permit No. a5 69 2-0� l �; -1 I Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
Townsend, Curtis L.
From: Mark Fondren <mfondren@hdlalaska.com>
Sent: Wednesday, July 12, 2023 2:34 PM
To: Townsend, Curtis L.
Cc: Christopher J. Bowman
Subject: RE: Change Order - Loma Est L1 131 review comments
Attachments: 20230712 - 18-021-52 - Loma Est L1 B1.pdf
[EXTERNAL EMAIL]
Curtis,
Thank you for your time to discuss this project yesterday. Please see my responses to your comments below, and
attached revised drawings. I look forward to hearing from you soon.
Thank you,
MARK FONDREN, PE
Civil Engineer HM
o: 907.564.2120 1 c: 832.260.2905
wwwMDLalaska.com its
From: Townsend, Curtis L. <Curtis.Townsend@anchorageak.gov>
Sent: Friday, July 7, 2023 5:30 PM
To: Mark Fondren <mfondren@hdlalaska.com>
Cc: Christopher J. Bowman <cbowman@hdlalaska.com>
Subject: Change Order - Loma Est L1 B1 review comments
OSP221371 Loma Est L1 B1
Hello Mark,
Thanks for your patience. Here are my comments on this change order:
I. C-101 Your visual description of the existing trenches differs than what you submitted to us at permit request.
Did you confirm visually that this is how the existing system is orientated? This is important because we require
horizontal separations between the new field and the old. See 15.65.210 B1g
The existing system location as shown on the plans is based on the following information
® The contractor excavated into the side of the existing system when setting the new septic tank
® Reviewing the MOA records more closely, the existing system was located as shown
It is relevant to note the survey sheet provided by our client does not appear to match with what we observed in
the field.
The proposed system should be able to have greater than 6 FT offset to the existing field, and I have revised the
drawings to indicate this.
2. C-101: Bed width is controlled by 15.65.210 D2c You can justify bed width being larger if you desire.
We propose to install a 24 FT x 24FT bed soil absorption system wider than 15 FT specified in 15.65.210 because
we want to maintain adequate separation from the existing soil absorption system and available area on the lot
is limited. The lot will allow for the bed soil absorption system (SAS) to be constructed without tracking
equipment over the SAS; I have added a note to the detail drawing for the SAS.
1
3. G-003 is it not desirable to have the DESIGN POINT closer to the OPERATING POINT on the pump curve?
The design point shows based on the input parameters the feet of head and flow rate required. The operating
point shows how the system will perform with the selected pump. The operating residual head will be higher
than the 5 FT residual design point. The residual head will be approximately 25 - 26 FT (11psi) and will keep the
system adequately pressurized.
4. V-101: existing trench description doesn't match what is shown on C-101. Please coordinate. See comment #1
above
I have remove V-101 from our plan set as discussed.
5. V-101: can you show the location of the new test pit dug in June 2023 on this page with the 30' radius?
I have removed V-101 from our plan set.
6. C-101: can you show all test holes dug in support of this project on this page with 30' radii around each?
Yes. The test holes were originally not included because they are greater than 30' away from proposed soil
absorption system. Please see revised C-101.
7. C-103: bottom of bed sewer rock looks to be at approximately 634'. This is approximately 2.5'— 3.5' bgs. Please
justify that this will all be draining into the soil strata that you performed the perc test in. Perc test was
performed at 3.5' bgs. Looks like from your soil log there is a different layer between 2 — 3.5'. Or justify that this
is all similar soil.
The bottom of the sewer rock is approximately at 3 FT below ground surface and the soil absorption system will
be draining into the same soil strata as the perc test at 3.5 FT.
I would like to explain the test pit log. The soil has the same classification from 2.0 FT to 7.5 FT (sp/SP). The soil
changes on the test pit log are identified by the lines that run halfway across the page under subsurface
material. According to our geotech group, the uppercase SP at 3.5 FT identifies lab testing was used for the soil
classification and not a change in soil type. The sm classification at 8.0 FT is not capitalized because testing to
distinguish between silt or clay was not performed.
8. C-301: please clarify native sand below sewer rock? This makes it look like you are installing a sand filter layer
below the sewer rock. Not needed since the soil is classified as SP.
The native SP soils will be used, not a sand liner. I revised detail drawing to clarify.
9. C-301: laterals should be located in the middle vertically of the sewer rock. it appears you have the laterals
located towards the top of the sewer rock.
I have revised the drawings to indicate 2" of sewer rock above the laterals.
Curtis Townsend, PE
Onsite Water and Wastewater
Municipality of Anchorage
907-343-7908
From: Mark Fondren <mfondren@hdlalasl<a.com>
Sent: Monday, June 26, 2023 5:00 PM
To: Townsend, Curtis L. <Curtis.Townsend@anchorageak.gov>
Cc: Christopher J. Bowman <cbowman(@hdlalaska.com>
Subject: Change Order - Loma Est L1 B1- (1 of 2 emails)
[EXTERNAL EMAIL]
2
Civil
Engineering
Geotechnical
Engineering
Transportation
Engineering
Aviation
Engineering
W/WW
Engineering
Environmental
Services
Surveying &
Mapping
Construction
Administration
Material
Testing
"ENGINEERING
'Consultants LLc
MEMORANDUM /Co,•
;5r
41 • • -'•'
Date: June 21, 2023 -/j ' � ,t
2A .
To: Alaska Native Tribal Health Consortium • • •• • • MarkFcxxkenll • • •�
,% ,• Daft No
June 2023 •. st
From: Mark Fondren, PE rIlk
l �?°. CE tTs3•U
�PROFES$10NA,
Subject: Geotechnical Memo
Platt Residence Test Pit & Percolation Testing
Loma Estates L1 131
HDL Engineering Consultants, LLC (HDL) conducted a test pit and percolation testing in
support of a wastewater system replacement at the Platt residence located at 16910 Bettijean
Street in Anchorage, Alaska (Site). This geotechnical memo is subject to the attached
limitations.
HDL conducted a falling head percolation test in an excavated test pit (TP -01) near the
proposed soil absorption system on May 31, 2023. We conducted the test in general
accordance with the Environmental Protection Agency's Falling Head Percolation Test
Procedure by placing a 4 -inch diameter standpipe in a bench adjacent to TP -01. The final depth
of the standpipe was approximately 3.5 feet below the existing ground surface (bgs). See HDL
TP -01 on the attached Site Plan for the test pit location.
The test pit encountered an organic mat followed by layers of poorly graded sand with varying
amounts of silt and gravel extending to the test pit termination depth. HDL collected grab
samples at select depths and returned them to HDL's laboratory for testing. See the attached
Test Pit Log for detailed soil information and results of the laboratory testing.
HDL observed a groundwater seep during excavation at a depth of approximately 7.5 feet bgs.
HDL installed a slotted 2 -inch PVC pipe in TP -01 to monitor groundwater levels at the Site. On
June 8, 2023 we measured groundwater in the PVC pipe at a depth of approximately 8.75 feet
bgs. We adjusted the groundwater depth by 1 foot in accordance with the Municipality of
Anchorage code 15.65. The resulting adjusted seasonal high groundwater level at the Site is
7.75 feet bgs.
Due to the permeable nature of the soil, HDL collected 7 measurements of the time it took for
the water level in the standpipe to drop 6 inches. Table 1 presents the results of the percolation
test.
3335 Arctic Boulevard, Suite 100, Anchorage, Alaska 99503
202 West Elmwood Avenue, Palmer, Alaska 99645
907.564.2120
907.746.5230
Geotechnical Memo, Platt Residence Percolation Testing
June 21, 2023
Table 1 - Percolation Test Results
Drop in water
level(inches)
6.00
Time Interval
(minutes)
0.96
Percolation Rate
(minutes per;
inch)
0.16
6.00
1.05
0.18
6.00
1.13
0.19
6.00
1.19 ,
0.20
6.00
1.27
0.21
6.00
1.33
0.22
6.00
1.35
0.23
Per the Falling Head Percolation Test Procedure, the last measurement taken represents the percolation
rate. Based on the last measurement, the calculated percolation rate was 0.23 minutes per inch.
We appreciate the opportunity to provide this service. If you have any questions, please feel free to
contact Mark Fondren at mfondren@hdlalaska.com or 907.564.2120.
Attach: Limitations (2 pages)
Boring Log Key (1 Page)
Test Pit Log (1 page)
Grain Size Distribution Curve (1 page)
Site Plan (1 page)
GEOTECHNICAL LIMITATIONS
Use of Report
1. HDL Engineering Consultants, LLC (HDL) prepared this report on behalf of, and for the
exclusive use of our Client for the stated purpose(s) and location(s) identified in the
Proposal for Services and/or Report. Use of this report, in whole or in part, at other
locations, or for other purposes, may lead to inappropriate conclusions; and we do not
accept any responsibility for the consequences of such use(s). Further, reliance by any party
not expressly identified in the agreement, for any use, without our prior written
permission, shall be at that party's sole risk, and without any liability to HDL.
2. If substantial time has elapsed between submission of this report and the start of work
at the site, or if conditions have changed because of natural causes or construction
operations at or adjacent to the site, we recommend that HDL be retained to review this
report to determine the applicability of the conclusions considering the time lapse or
changed conditions.
Standard of Care
3. HDL's findings and conclusions are based on the work conducted as part of the Scope of
Services set forth in the Proposal for Services and/or Report, and reflect our professional
judgment. These findings and conclusions must be considered not as scientific or
engineering certainties, but rather as our professional opinions concerning the limited data
gathered during the course of our work. If conditions other than those described in this
report are found at the subject location(s), or the design has been altered in any way, HDL
shall be so notified and afforded the opportunity to revise the report, as appropriate, to
reflect the unanticipated changed conditions.
4. HDL's services were performed using the degree of skill and care ordinarily exercised by
qualified professionals performing the same type of services, at the same time, under
similar conditions, at the same or a similar property. No warranty, expressed or implied, is
made.
Subsurface Conditions
S. The generalized soil profile(s) provided in our Report are based on widely -spaced
subsurface explorations and are intended only to convey trends in subsurface conditions.
The boundaries between strata are approximate and idealized, and were based on our
assessment of subsurface conditions. The composition of strata, and the transitions
between strata, may be more variable and more complex than indicated. For more
specific information on soil conditions at a specific location refer to the exploration logs.
6. Unanticipated soil conditions are commonly encountered and cannot be fully
determined by merely taking soil samples or advancing borings. Such unexpected
conditions frequently require additional expenditure to attain a properly constructed
project. Therefore, some contingency fund is recommended to accommodate such
potential extra costs.
7. In preparing this report, HDL relied on certain information provided by the Client, state
and local officials, and other parties referenced therein which were made available to HDL
at the time of our evaluation. HDL did not attempt to independently verify the accuracy
or completeness of all information reviewed or received during the course of this
evaluation.
8. Water level readings have been made in test holes (as described in the Report) and
monitoring wells at the specified times and under the stated conditions. These data have
been reviewed and interpretations have been made in this Report. Fluctuations in the
level of the groundwater occur due to temporal or spatial variations in areal recharge
rates, soil heterogeneities, the presence of subsurface utilities, and/or natural or
artificially induced perturbations. The water encountered in the course of the work may
differ from that indicated in the Report.
9. HDL's services did not include an assessment of the presence of oil or hazardous materials
at the property. Consequently, we did not consider the potential impacts (if any) that
contaminants in soil or groundwater may have on construction activities, or the use of
structures on the property.
10. Recommendations for foundation drainage, waterproofing, and moisture control address
the conventional geotechnical engineering aspects of seepage control. These
recommendations may not preclude an environment that allows the infestation of mold
or other biological pollutants.
Compliance with Codes and Regulations
11. We used reasonable care in identifying and interpreting applicable codes and regulations.
These codes and regulations are subject to various, and possibly contradictory,
interpretations. Compliance with codes and regulations by other parties is beyond our
control.
Additional Services
12. HDL recommends that we be retained to provide services during any future: site
observations, design, implementation activities, construction and/or property
development/redevelopment. This will allow us the opportunity to: i) observe
conditions and compliance with our design concepts and opinions; ii) allow for changes
in the event that conditions are other than anticipated; iii) provide modifications to our
design; and iv) assess the consequences of changes in technologies and/or regulations.
Summary of the Unified Soil Classification System
(from ASTM International Standard D2487)A
Soil Classification
Group Symbol Group Names
Coarse-grained Soils
(More than 50°° retained on
No. 200 sieve)
Gravels
(More than 50°° of
coarse fraction
retained on No. 4
sieve)
Gravels with
<5%finest
Cu>_4 and 1:5C,530
GW
Well -graded grave IE
Cu<4 and/or [Cc<1 orCc>3 °
�
GP
Poorly
y graded gravelE
Gravels with
> 12% finest
Fines classify as ML or MH
GM
Silty gravelEAG
Fines classify as CL or CH
GC
Clayey gravelE,P,G
Sands
°
(50/ or more of coarse
fraction passes No. 4
sieve)
Sands with
< 5%fines"
Cu<3°
>_6 and 15C ,-
SW
Well -graded sand
C"<6 and/or [C<<1 or Cc>3]°
SP
Poorly graded sand'
Sands with
> 12% fines"
Fines classify as ML or MH
SM
Silty sandF,G,i
Fines classify as CL or CH
Sc
Clayey sandF,G,t
Fine-grained Soils
(More than 50°° passes the
No. 200 sieve)
Silts and Clays (LL<50)
Inorganic
PI>7 and plots on or above "A" line'
CL
Lean clay KLM
PI<4 or plots below "A" line'
••
ML
SiltK,L,M
Organic
LL - Oven dried/LL - Not dried <035
OL
Organic clay/siltK,L M,14/0
Silts and Clays (LL>50)
Inor
Inorganic
g
PI plots on or above "A" line
CH
Fat clayK,L,M
PI plots below "A" line
MH
Elastic siltK,L,M
Organic
LL - Oven dried/LL - Not dried <035
OH
Organic clay/siltK,L M,P/a
Highly Organic Soils
Primarily organic matter, dark in color, and organic odor
PT
Peat
NOTES:
Visual soil descriptions performed in accordance with ASTM D2488
Lowercase USCS abbreviation indicates field classification
Uppercase USCS abbreviation indicates laboratory classification
`Based on the material passing the 3 -in. (75 -mm) sieve
BIf field sample contained cobble or boulders, or both, add "with cobbles or
boulders, or both" to group name
'Gravels with 5 to 12% fines require dual symbols:
GW -GM well -graded gravel with silt
GW -GC Nell -graded gravel with clay
GP -GM poorly graded gravel with silt
GP -GC poorly graded gravel with clay
° C =D60 D o, C (D3o)2/(131oxl)m)
EIf soil contains > 15° o sand, add "with sand" to group name
Flf fines classifv as CL -ML, use dual svmbol GC -GM, or SC -SM
60
so
e 40
Z
30
20
a
10
7
4
0
rlf fines are organic, add "with organic fines" to group name
"Sands with 5 to 12% fines require dual symbols:
SW -SM well -graded sand with silt
SW -SC well -graded sand with clay
SP -SM poorly graded sand with silt
SP -SC poorly graded sand with clay
'If soil contains >15% gravel, add "with gravel" to group name
'If Atterberg limits plot in hatched area, soil is a CL -ML, silty clay
KIf soil contains 15 to < 30% plus No. 200, add "with sand" or "with gravel", whichever is
predominant
If soil contains > 30% plus No. 200, predominantly sand, add "sandy" to group name
"If soil contains > 30% plus No. 200, predominatly gravel, add "gravelly' to group name
. > 4 and plots on or above "A" line
°PI < 4 or plots below "A" line
PPI plots on or above "A" line
QPI plots below "A" line
For classification of Fine-grained soils.'
SAMPLE TYPES
Symbol
Description
SS
And fine-grained fraction of coarse-grained
y
Modified Split Spoon
G
Grab
Soils.
Shelby Tube
Equation of "A" — line
Push Sample
C
v--�--�
8-15
1.0-2.0
Horizontal at PI = 4 to LL = 25.5,
15-30
2.0-4.0
Hard
>30
>4.0
then PI = 0.73 (LL- 20)
1/16 - 3/16
2.0-4.7
Medium
1/64-1/16
0.42-2.0
Equation of"U"line
oe
0.074-0.42
Silt and Clay
<1/256
<0.074
vertical at LL = i6 to PI = 7,
then PI = 0.9 (LL - 8) /
G
t �
1
Ir
MH oR OH
V (
D
I I
-� is 'M
_
ML o OL
j
I
vu W bu 70 00 90 100 110
LIQUID LIMIT (LL)
_
SAMPLE TYPES
Symbol
Description
SS
Split Spoon
MSS
Modified Split Spoon
G
Grab
ST
Shelby Tube
DP
Push Sample
C
Core
RELATIVE SOIL DENSITY
SOIL CONSISTENCY
N -Value
Description
N -Value
_
Pocket Pen.
Very Soft
<2
<0.25
Soft
2-4
0.25-0.5
Medium
4-8
E5 - 1.0
Stiff
8-15
1.0-2.0
Very Stiff
15-30
2.0-4.0
Hard
>30
>4.0
RELATIVE SOIL DENSITY
GRAIN SIZE
N -Value
Size Class
Inches
mm
Boulders
>12 inches
>300
Cobbles
3 to 12
75-300
Gravel
Coarse
3/4 - 3
19.0 - 75
Fine
3/16-3/4
4.76-19.0
Sand
Coarse
1/16 - 3/16
2.0-4.7
Medium
1/64-1/16
0.42-2.0
Fine
1/256 -1/64
0.074-0.42
Silt and Clay
<1/256
<0.074
RELATIVE SOIL DENSITY
Description
N -Value
Very Loose
0-4
Loose
5-10
Medium Dense
11-30
Dense
31-50
Very Dense
>50
COMPONENT
PROPORTION
(Visual)
Term Range
Trace 0-5%_
Little 5 - 15%
Some
And
r
a
W
W
F
LL
O
U
D
fa
rZ M1ENGINEERING LOG OF TEST PIT TEST PIT # TP -01
hl�q issConsultantsLLc
PROJECT NUMBER: 18-021-52
PROJECT: Anchorage Scattered Sites - Platt
CLIENT: ANTHC
Sample
Data
Ground Water Data
Geologist: K. Horning Total Depth: 13.8 feet
W�
Depth in (ft.) 8-75
o
Field Crew: A+ Home Services Date: 513112023
LL
t–
E
m N
o.
Equipment Type: CAT 430E
Time
y
a
z
a
rn . � c
Location: Anchorage, Alaska
Date 5/31/23 6/8/23
Sy,, b°i
E
E
v m o—
Lat/Long: 61.06771, 149.78228
rn
LL
cn
j U LL
in
0
SUBSURFACE MATERIAL
ORGANIC MAT
1
Sm:o;
•:
Poorly -graded SAND, (sm); fine to coarse; with gravel, fine to coarse, subangular to rounded; 0.6
some silt; brown, moist; cobbles, trace root hairs
2
spPoorly-graded
SAND, (sp); fine to coarse; trace gravel, fine to medium, subrounded; trace silt; 2.0
3
brownish gray, moist;
4
GRAB
S-5
SP
(SP); dark brown 3.5
P200 =1.9°1°, Sa =97.3%, Gr =0.8°1°, Moisture =5.6%
5
GRAB
S-2
Moisture=4.3°l0
6
7
8
GRAB
S-3
Sm
Poorly -graded SAND, (sm); fine to coarse; with silt; little gravel, fine to coarse, subrounded to 7'5
subangular; dark gray, moist; groundwater seep at 7.5 feet bgs
9
P200 =30.3%, Sa =59.4%, Gr =10.3°/0, Moisture =15.7%
10
11
GRAB
S-4
sp-sm
o:
10.5
Poorly -graded SAND, (sp-sm); fine to coarse; some gravel, fine to coarse, subangular to
subrounded; trace to little silt; brownish gray, moist; digging becomes more difficult with depth
:
'o:
12
Moisture =8.61° 11.5
Boulder encountered at 11.5 ft bgs.
13
BOH
Notes:
13.s
Terminated test pit at 13.8 feet bgs due to excavator refusal. Stepped over and performed 13.8
percolation test at a depth of approximately 3.5 feet bgs
E
+ u
FF, ro
7
, f 7
a
rt`
Sheet Number 1 of 1
:' 11■�■IIIIIII� �'"'�IIYl�iiil IIIYIIIII■1■IIIIIII■IIIIIII■�
.,11■IIIHill! ■�IIIIIl■■I�11111■IPoll ■III
IIII■�
11■X1111111■®Illlirlm11►111■■�IIIIIII■Mill IIII■NO
III OUR I■®Hill II 71111111■IHill II■IIIIIII■M
III UPON ■®1111111■111'111■ 111111■■Hill l■■�
INN �IIIIIII■®ONE 1■�IIIIII®I■�111111■■IllOil
1■■mIIIIII■■1111111■11111111■IIIIIII■IIIIIII■�
INN IIIIHIM ®111111■■IIIIIII �IIIIII■■m IIIIII■�
.. 11■IHillis ®III IIII■�OUR II\IIIIIII■MI I
1■■IIIIIII■■IIIIIII■mill 11111■1Hill Millis
INN �IIIIIII■®UPON ■�IIIIII[in 'illilll■■IIIIIII■�
1■■III1111111 111111■■�IIIIIIII \IIMI■�IIIIIII■�
1■■mIIIIIII■®IIIIIII■ONIIIIIIII��111111■■oI 1111■�
,11■M111111■■®IIIIIII■�OUR III�111111■■IIIIII■■t
11■IIIIIII■IIIIIII■�OUR 1111111■IIIIIII■�
,11■IOU I■®111111■■IIIIII■m IIIIII■■mIIIIIII■�
11■IIIIIII■■®IIIIIII■wIIIIII11111111 IIIIIII■�
III �I111111■IIIIIII■ONE ■11111111■IIIIIII■�
11■1111111■®IIIIIII■IIIIIII■`i1111111■IIIIIII■■�
.II■BRUIN! ®HOME HOW ■HUHN 1111111■�
COBBLES GRAVEL SAND SILT OR CLAY
coarse fine coarse I medium I fine
Specimen Identification Classification LL PL PI Cc Cu
, • TP -01 DEPTH 3.5 POORLY GRADED SAND(SP) 1.06 2.45
c
El TP -01 DEPTH 8.0
o Specimen Identification D100 D60 D30 D10 %Gravel I %Sand I %Silt %Clay
• TP -01 DEPTH 3.5 19 0.384 0.252 0.156 0.8 97.3 1.9
Z TP -01 DEPTH 8.0 25.4 0.227 10.3 59.4 30.3
Im
M&ConsyKaOtaLLSC
ENGINEERING
3335 Arctic Blvd Ste 100
Anchorage, AK 99503
Telephone: 907-564-2120
GRAIN SIZE DISTRIBUTION
Project: Anchorage Scattered Sites - Platt
Client: ANTHC
Project Number: 18-021-52
n SITE PLAN • D. PLATT
SCOPE OF WORK/ NOTES:
1. FII "DE NEI SEPTIC STEL 0 REPLAGE THE -5— FAILING SEPTIC STSTEL, SKISTINC HELL
AND HATER GER.CE LINE TO REMAIN IN SERVICE,
2. INSTALL NEI " ACS $EW£ SERVICE WITH 2' IkSULATION NO— AD— PIPE, AS SROM M
SHEET SSA-AGO,
1 INSTALL EW %1""
AO-GALLON SEPTIC TANK, E GAI COAlEO STESI — LIFT STATIM R+CAI
INCHMAGE TANK. SEE CS-SO1 Fp SEPTIC TANK DETAILS,
ManN Nmvmw�
+. INSTALL NEI PNESSLAIINDN BED SYSTEM AS SHORN ON SITE PINI ANG PRCGII£ CRAW[NGS. •�MWNM
SHEETS C-101, C-iD2, C-103.
5. PUMP-OUT, AND RELOYE THE EXISTING SEPTTD TANK. ALI— EAISTING GRAINFIELD IN PLAE" ulnae
REMOTE 4MIT(a'tiNG PORTS. CGLPACT, "IL. ANO I'D DATE DISTURBED ARG_
G. _0SW FILL NOT SHO^ FOR CLARITY, SEE C-1D2.
aY1MYt 1. RATTtls2�uRT�Tf55UBGnvoN
:. oRUTA",
SFTEP H-PIATT
0-101
E— 2 Gr
rr
Q ,
• , ALASKA NATIVE
• ® TRIBAL HEALTH
• CONSORTIUM
DIVISION OF ENVIRONMENTAL
HEALTH AND ENGINEERING
4500 DIPLOMACY DRIVE
ANCHORAGE, ALASKA, 99508 -Mo
PHONE: (907) 7293600
FAX: (907) 729-0090
httpJrwvm.dehe.org
ANCHORAGE, ALASKA
SCATTERED SITES- PLATT
ISSUED FOR REVIEW
PLAN SET NUMBER: AKA -2I -ANC PHASE II
ANTHC PROJECT NUMBER: AKAC6K-1276SSS
JSER: JERHARDT PRODUCT: AutoCAD 2016 — English FILE: H:\lobs\18-021 anthc term contract 18—tc-161654 (anthc)\52 — well and septic designs — 2 anchorage
Co 44- 1
SHEET LIST TABLE
G-001
GENERAL LEGEND
G-002
DESIGN CRITERIA
G-003
PUMP SELECTION CALCULATIONS
C-001
CIVIL LEGEND
C-101SITE
PLAN - PLATT
C-102
PLAN - PLATT
C-103
PROFILE - PLATT
C-301
SECTION - PLATT
CS -501
SEPTIC TANK DETAIL
SSSD-301
SEWER SERVICE AND CLEANOUT - ABS PIPE
SSSD-400
SEWER SERVICE LINE TRENCH
LAYOUT: COVER PRINTED: 7/11/2023 4:37:27 PM
1 OF 12 TOTAL 5HEE1S
GENERAL SYMBOLS
�NUMBER
X D
X VIEW TITLE
(�7
7 SCALE XX"-XX'T. SCALE XX" -XX'
VIEW NUMBER
VIEW NUMBER
x 1
x-xxx
SHEET NUMBER
C VIEW NUMBER
x
x—xxx
SHEET NUMBER
VIEW NUMBER
x
x-xxx
SHEET NUMBER
0 1- 2-
B 0 10000' 20000'
—J�
MATCH LINE, SEE X—XXX
0
USER: JERHARDT PRODUCT: AutoCAD 2016 — English
DRAWING TITLE
OR SECTION TITLE
DRAWING TITLE OR
SECTION TITLE WITH
VERTICAL AND
HORIZONTAL SCALE
SECTION INDICATOR
DRAWING OR PHOTO/IMAGE
ELEVATION INDICATOR
CALL OUT BUBBLE
ARCHITECTURAL
GRAPHIC SCALE
ENGINEERING
GRAPHIC SCALE
BREAK LINE
KEY NOTE INDICATOR
(REFERS TO NOTE
ON SAME SHEET)
MATCH LINE
REVISION INDICATOR
FILE: H:\iohs\18-021 onthc term contract 18—tc-161654
ra
ABBREVIATIONS
ABS ACRYLONITRILE BUTADIENE STYRENE
ADEC
ALASKA DEPARTMENT OF
ENVIRONMENTAL CONSERVATION
ALUM
ALUMINUM
ANSI
AMERICAN NATIONAL STANDARDS
INSTITUTE
APPROX APPROXIMATE
ARV
AIR RELEASE VALVE
AS
ASPHALT
AVEC
ALASKA VILLAGE ELECTRIC
COOPERATIVE
AVG
AVERAGE
AMERICAN WATER WORKS
AWWA
ASSOCIATION
BH
BORE HOLE
BLDG
BUILDING
BMP
BEST MANAGEMENT PRACTICE
BOH
BOTTOM OF HOLE
BTU
BRITISH THERMAL UNITS
CFM
CUBIC FEET PER MINUTE
CL
CENTERLINE
CO
CLEANOUT
CONC
CONCRETE
CMP
CORRUGATED METAL PIPE
DCCED
DEPARTMENT OF COMMERCE AND
ECONOMIC DEVELOPMENT
DIA
DIAMETER
DI
DUCTILE IRON
DIST
DISTANCE
DWV
DRAIN WASTE VENT
EG
EXISTING GROUND/GRADE
ELEC
ELECTRIC
ELEV
ELEVATION
FF
FINISHED FLOOR
FG
FINISHED GROUND/GRADE
FLG
FLANGE
FM
FORCE MAIN
FPS
FEET PER SECOND
FPT
FEMALE PIPE THREAD
GA
GAUGE
GALV
GALVANIZED
GPD
GALLONS PER DAY
GPM
GALLONS PER MINUTE
HDPE
HIGH DENSITY POLYETHYLENE
HORZ
HORIZONTAL
HP
HORSEPOWER
HUD
DEPARTMENT OF HOUSING AND
URBAN DEVELOPMENT
H WL
HIGH WATER LEVEL
— well and septic designs — 2 anchorage
j
ID INSIDE DIAMETER
I/I INFILTRATION /INFLOW
INV INVERT
IPS IRON PIPE SIZE
LB POUNDS
LF LINEAR FEET
LPS LOW PRESSURE SEWER
LPSS LOW PRESSURE SEWER SERVICE
MAX MAXIMUM
MH MANHOLE
MIN MINIMUM
MLLW MEAN LOWER LOW WATER
MPT MALE PIPE THREAD
NFS NON FROST SUSCEPTIBLE
NPSH NET POSITIVE SUCTION HEAD
NSF NATIONAL SANITATION FOUNDATION
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OSHA OCCUPATIONAL SAFETY & HEALTH
ADMINISTRATION
PE POLYETHYLENE
PERC PERCOLATION
PEX CROSS—LINKED POLYETHYLENE
PP POWER POLE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PERCOLATION TEST
PVC POLYVINYL CHLORIDE
REPS RESIDENTIAL EFFLUENT PUMPING
STATION
ROW RIGHT OF WAY
SDR STANDARD DIMENSIONING RATIO
SL SLOPE
SS SEWER SERVICES OR STAINLESS
STEEL
STA STATION
SUBD SUBDIVISION
SWPPP STORM WATER POLLUTION
PREVENTION PLAN
SWT SWEAT
TDH TOTAL DYNAMIC HEAD
THD THREADED
TYP TYPICAL
UHM W ULTRA HIGH MOLECULAR WEIGHT
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
WST WATER STORAGE TANK
WTP WATER TREATMENT PLANT
G—STGENL.dwq
PF
LO
(P
LAYOUT: G—LGND
( 'n N-1
4
SECTION 11, T11N, R3W, SEWARD MERIDIAN, ALASKA,
USGS QUAD: ANCHORAGE A-8
VICINITY MAP
SCALE: 1" = 2040'
;1:1k'I e1�►C�)I�
THESE DRAWINGS HAVE BEEN DEVELOPED FOR CONSTRUCTION BY
CONSTRUCTION CONTRACT METHODOLOGY. CONSTRUCTION
SPECIFICATIONS HAVE ALSO BEEN DEVELOPED SPECIFICALLY FOR
THIS PROJECT. TOGETHER, THE DRAWINGS AND CONSTRUCTION
SPECIFICATIONS CONSTITUTE A COMPLETE AND INSEPARABLE SET OF
CONSTRUCTION DOCUMENTS, INCLUDING ALL NECESSARY
CONSTRUCTION AND MATERIALS SPECIFICATIONS TO ENSURE THE
PROJECT AS CONSTRUCTED MEETS THE DESIGN INTENT. ANY
CHANGES TO CONSTRUCTION METHODS OR MATERIALS SHALL BE
APPROVED IN ADVANCE BY THE RESPONSIBLE REGISTERED
PROFESSIONAL.
PRINTED: 7/11/2023 4:37:38 PM
0
a
Division of Environmental
Health and Engineering
4590 Diplomacy Drive
Anchorage, Alaska 99508
(907) 729-3600
i ykP . ' '• l f1
iii `S7
fff`s '•.•. ti�'�
ff ir'aE0�5,�
0 1 -
BAR IS ONE INCH ON
ORIGINAL DRAWING, IF NOT
Qat
LU W CC
W
CC
oC N 0
p O W
W
U W
W
a�NQ _
U
e�
PROJ ENG: MEF
DRUMS ENG: ----
DRAWN BY: JSE
SHEET TITLE
GENERAL LEGEND
G-001
SHEET 1 OF S
2 OF 12 TOTAL SHE
I I 1
j
GENERAL NOTES
REFERENCES
1.
THESE PLANS ARE BASED ON TOPOGRAPHIC SURVEY INFORMATION PROVIDED BY ANTHC IN SUMMER 2022. THE CONTRACTOR SHALL
1. STATE OF ALASKA ADEC ONSITE WASTEWATER SYSTEM INSTALLERS MANUAL, JANUARY 2016.
•
VERIFY SITE CONDITIONS, DIMENSIONS, AND DETAILS PRIOR TO THE START OF CONSTRUCTION. IF ANY DISCREPANCIES AND/OR
® s
UNKNOWN CONDITIONS WHICH AFFECT THE PROJECT ARE FOUND, THE CONTRACTOR SHALL NOTIFY ANTHC AND THE PROJECT
2. ADEC WASTEWATER DISPOSAL REGULATIONS 18 AAC 72, NOVEMBER 2017.
ENGINEER. THE CONTRACTOR MAY BE REQUIRED TO PROVIDE MINOR LAYOUT CHANGES IN THE FIELD BASED ON ACTUAL SITE
CONDITIONS. VERIFY ALL CHANGES WITH ANTHC AND THE PROJECT ENGINEER PRIOR TO PROCEEDING.
3. MUNICIPALITY OF ANCHORAGE WASTEWATER REGULATIONS, AMC 15.65.
e •
2.
IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND
®
COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY
OF ALL PERSONS
SORS. AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
WORKING
DESIGN CRITERIA
D
Division of Environmental
3.
CONTRACTOR SHALL FIELD VERIFY EXISTING UTILITIES BEFORE CONSTRUCTION. CONTRACTOR SHALL PROTECT UTILITIES AT ALL
PLATT SEPTIC SYSTEM
Health and Engineering
TIMES DURING CONSTRUCTION AND REPAIR DAMAGES IN ACCORDANCE WITH THE RESPECTIVE UTILITY COMPANY REQUIREMENTS.
4500 Diplomacy Drive
4.
CONTRACTOR SHALL INSTALL ALL MATERIAL AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS,
3 BEDROOM HOUSE. DESIGN FLOW RATE: 150 GAL/DAY/BEDROOM. TOTAL DESIGN FLOW: 450 GAL/DAY
Anchorage, Alaska 99508
(907)729.3s90
INSTRUCTIONS, AND INSTALLATION DRAWINGS, UNLESS INDICATED OTHERWISE.
GEOTECH MEMO SUBMITTED SEPARATELY WITH PLANS INCLUDES HDL TEST PIT LOG & PERC TEST INFORMATION
5. CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE, STATE AND FEDERAL OCCUPATIONAL
SAFETY & HEALTH REGULATIONS, ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION, AND ALL OTHER FEDERAL, STATE, AND.
HDL TEST PIT TP -01 EXCAVATED ON MAY 31, 2023 (SEE SHEET C-107 FOR LOCATION). TARGET RECEIVING SOILS AT 3 FT�e
.•''������►4
LOCAL LAWS AND REGULATIONS PERTAINING TO THIS PROJECT. ANY WORK PERFORMED BY THE CONTRACTOR CONTRARY TO SUCH
BELOW GROUND SURFACE (BGS) WERE CLASSIFIED AS SP. PERCOLATION TEST CONDUCTED IN BENCH NEAR TP -01 AT 3.5 FT
� *""?......•i•
LAWS OR REGULATIONS SHALL BE MET AT THE CONTRACTOR'S SOLE RISK AND EXPENSE.
BGS HAD PERCOLATION RATE OF LESS THAN 1 MIN/1N. DURING EXCAVATION A GROUNDWATER SEEP WAS OBSERVED AT 7.5 FT`:<•••
6.
WORK SHALL BE PERFORMED WITH SKILLED CRAFTSMEN SPECIALIZING IN THE REQUIRED WORK. INSTALL ALL MATERIALS IN A NEAT,
BGS IN TP -01. JUNE 8, 2023 GROUNDWATER WAS MEASURED IN HDL TP -01 AT 8.75 FT BGS. A 1 FT ADJUSTMENT FACTOR
WAS APPLIED (TABLE 1, AMC 15.65) TO THE JUNE 8, 2023 GROUNDWATER READING. ADJUSTED SEASONAL HIGH GROUNDWATER
a a :?�•
:gye
ORDERLY, AND SECURE FASHION, AS REQUIRED BY THE CONTRACT DOCUMENTS AND COMMONLY RECOGNIZED STANDARDS OF GOOD
LEVEL IS 7.75 FT BGS IN HDL TP -01.
6`0
0- = �w
WORKMANSHIP.
'
7.
ALL EXCAVATIONS SHALL BE SLOPED AND SHORED AS REQUIRED FOR SAFETY OF PERSONNEL AND TO ENSURE THAT EXISTING
BED SYSTEM APPLICATION RATE: 0.8 GAL SQ FT TABLE 2, AMC 15.65
/ ( )
• r '••
• s
STRUCTURES, UTILITY POLES, AND UNDERGROUND UTILITIES ARE NOT COMPROMISED. UTILIZE PORTABLE TRENCH SHIELDS OR OTHER
SUPPORT SYSTEMS IN COMPLIANCE WITH RELEVANT OSHA REGULATIONS.
BED SYSTEM ABSORPTION AREA REQUIRED: (3 BEDROOMS * 150 GAL/BEDROOM/DAY) / (0.8 GAL/SQ FT) = 563 SQ FT
•*► *'aE�:.�
►o,;,,�,.•
8.
CONTRACTOR SHALL PROTECT ALL MONUMENTS AND PROPERTY CORNERS. DAMAGED MOVED MONUMENTS AND CORNERS, WHETHER OR
BASED ON SITE AREA AVAILABLE - 24' WIDE BED REQUIRES LENGTH = [563 SQ FT / (24 FT)] =23.5 FT
_
D
NOT THEY ARE SHOWN ON THE DRAWINGS, SHALL BE PROPERLY SURVEYED AND REPLACED IN THEIR PRECONSTRUCTION CONDITION.
SUBMIT SURVEY FIELD BOOK TO PROJECT ENGINEER AFTER CONSTRUCTION IF ANY MONUMENTS ARE IMPACTED.
A 24'X24' BED SOIL ABSORPTION SYSTEM IS PROPOSED
BAR IS ONE INCH ON
9.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE OVERALL CARE OF PROPERTY USED TO STAGE MATERIALS AND EQUIPMENT DURING
• LIFT STATION IS PROPOSED FOR 4' SEPARATION TO GROUNDWATER. DETAILS FOR LIFT STATION, AND FLOAT SETTINGS MAY BE
ORIGINAL DRAWING, IF NOT
CONSTRUCTION. FUEL, OIL, HYDRAULIC FLUID, AND OTHER PETROLEUM OR COMBUSTIBLE PRODUCTS SHALL BE STORED AND
FOUND ON CS -501. ANCHORAGE TANK SEPTIC TANK EFFLUENT PUMPING SYSTEM PACKAGE WITH 2" DISCHARGE, ON/OFF
ADJUST SCALES ACCORDINGLY
MAINTAINED AT A LOCATION ACCEPTABLE TO THE OWNER'S REPRESENTATIVE. FLOAT, HIGH LEVEL FLOAT, CONTROLLER, AUDIBLE AND VISUAL HIGH LEVEL ALARM OR EQUAL IS SPECIFIED.
10.
ALL EQUIPMENT OWNED BY THE CONTRACTOR SHALL BE KEPT IN GOOD REPAIR AT ALL TIMES. ALL POWERED EQUIPMENT SHALL BE
HYDRAULIC CALCULATIONS FOR PRESSURIZED BED SYSTEM AND PUMP CURVE ARE PROVIDED ON G-003. BASED ON PROVIDED
C
INSPECTED BEFORE AND AFTER EACH USE FOR ANY FUEL, HYDRAULIC OIL, OR COOLANT LEAKS. THE USE OF ANY POWERED
CALCULATIONS AN ORENCO P2005 HH EFFLUENT PUMP OR EQUAL IS SPECIFIED.
EQUIPMENT WITH KNOWN LEAKS IS PROHIBITED. SITE CLEAN-UP OF ANY ACCIDENTAL PETROLEUM LEAKS OR SPILLS ARE THE
RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE REMEDIATED IMMEDIATELY UPON DISCOVERY. ANY SPILL, REGARDLESS OF SIZE,
BUOYANCY CALCULATIONS - TOTAL VOLUME OF SEPTIC TANK (BASED ON DIMENSIONS) IS 1671 GALLONS - TANK WILL
MUST BE REPORTED TO THE OWNER'S REPRESENTATIVE AS SOON AS PRACTICAL. IN ADDITION, CONTRACTOR SHALL COMPLY WITH ALL
DISPLACE APPROXIMATELY 14,000 LBS OF WATER (ASSUMING WATER LEVEL AT TOP OF TANK). SURFACE AREA ABOVE TANK
Q
ADEC REQUIREMENTS IN 18 AAC 75.
EXCLUDING RISERS IS APPROXIMATELY 42 FT"2. ASSUMING TANK WILL HAVE 4' OF DRY SOIL WITH ESTIMATED DENSITY OF AT
J
LEAST 115 LB/FT-3. WEIGHT OF SOIL ABOVE TANK IS ESTIMATED 115 LB/FT-3 * 42 SQ FT *4 FT = 19,320 LBS. SOIL SHOULD
Y (L W
Q
11.
REFUELING OR OTHER FLUID HANDLING ACTIVITIES MAY HAVE SPECIAL RESTRICTIONS IN SENSITIVE AREAS, SUCH AS WITHIN 100
BE ADEQUATE TO KEEP TANK FROM FLOATING - GIVEN ASSUMED WATER LEVEL.
r >
FEET OF DRINKING WATER WELLS. ACCEPTABLE LOCATIONS FOR SUCH ACTIVITIES SHALL BE APPROVED BY THE OWNER'S
N W
REPRESENTATIVE. AN ADEQUATE SUPPLY OF ABSORBENT PADS SHALL BE KEPT ON SITE TO FACILITATE INITIAL REMEDIATION OF
SMALL PETROLEUM
FOUR CONCRETE ANCHOR BLOCKS - APPROXIMATELY 2'X2'X4* WERE STRAPPED TO TANK WITH STAINLESS STEEL CABLE FOR
W W CC
F -
SPILLS.U'
ADDITIONAL BUOYANCY RESTRAINT. RUBBER STRIPS WERE PLACED UNDER STEEL CABLE TO KEEP FROM SCRATCHING THE TANK.
BASED ON APPROXIMATE DIMENSIONS OF CONCRETE ANCHOR BLOCKS (PROVIDED BY CONTRACTOR) THE BLOCKS ARE 16 FT"3.
fA
cc 0
FOUR BLOCKS HAVE A TOTAL VOLUME OF 16 FT"3 * 4 = 64 FT"3. WEIGHT OF CONCRETE BLOCKS UNDER WATER IS 64 FT"3 *
O
WELL AND SEPTIC SYSTEM GENERAL NOTES
[150 LB/FT - 62.4 LB/FT"3]=5,606LBS. WEIGHT OF SOIL ABOVE BLOCKS WILL ADD EVEN GREATER BUOYANCY RESTRAINT.
W
1.
CONTRACTOR SHALL ABIDE BY MUNICIPALITY OF ANCHORAGE WASTEWATER REGULATIONS, AMC 15.65.
U cc W
2
CONTRACTOR SHALL VERIFY THAT ALL SEPARATION DISTANCES FOR SEPTIC TANK AND DRAINFIELD LOCATIONS STATED ON PLANS HAVE BEEN
z:3
3.
CONTRACTOR SHALL FURNISH ALL ON-SITE SEPTIC RELATED SUBMITTALS FOR APPROVAL PRIOR TO BEGINNING WORK.
U
4.
WITHIN 5 WORKING DAYS OF COMPLETION OF THE PROJECT THE CONTRACTOR SHALL PROVIDE A SET OF RED -LINED DRAWINGS TO THE
N
ENGINEER. DRAWINGS SHALL SHOW AS -BUILT MEASUREMENTS OF THE COMPLETE SYSTEM INSTALLATION. ALL SWING -TIE MEASUREMENTS
SHALL BE TAKEN TO THE NEAREST 1/10 FOOT. TAPE SHALL BE HELD TAUT TO PROVIDE AS ACCURATE A MEASUREMENT AS POSSIBLE.
5.
VERTICAL ELEVATION MEASUREMENTS SHALL BE TAKEN BASED ON THE FINISHED FLOOR OF THE BUILDING AT THE FOLLOWING POINTS, AT A
z
MINIMUM:
B
INLET AND OUTLET OF TANKS; TOP OF PIPE; EACH CLEANOUT
BEGINNING; MIDPOINT; AND END OF EACH DRAINFIELD BED AT:
ELEVATION OF BOTTOM OF DRAINFIELD BEDS
ELEVATION OF BOTTOM OF LATERAL PIPES
ELEVATION OF FINISHED GRADE
z
P
6.
CONTRACTOR SHALL SUBMIT SEPTIC SYSTEM DOCUMENTATION TO THE ENGINEER IN ACCORDANCE WITH SPECIFICATION SECTION 01 78 39
a
AND AMC 15.65.
u,
7.
SEWER ROCK AND COARSE FILTER SAND MUST MEET MUNICIPALITY OF ANCHORAGE SPECIFICATIONS.
8.
THE SEWER ROCK FOR BOTH SEPTIC SYSTEMS MUST BE RAKED LOOSE AND NOT COMPACTED BY EQUIPMENT.
9.
CONTRACTOR SHALL SUBMIT WELL DRILLING RESULTS AND INFORMATION TO THE STATE OF ALASKA'S WELL LOG TRACKING SYSTEM (WELTS),
AS REQUIRED BY 11 AAC 93.140(a).
a
0
PROJECT RESTORATION NOTES
1.
ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE RETURNED TO PRE -CONSTRUCTION CONDITION OR BETTER. CONSTRUCTION
PLAN SET. AKA -21 -ANC PHASE II
DEBRIS SHALL BE REMOVED FROM THE PROJECT AREA AND DISPOSED OF AS DIRECTED BY THE OWNER. CONTRACTOR SHALL
PROJ MGR: CJB
A
EXERCISE DUE CARE TO AVOID DISTURBING AREAS OUTSIDE THE WORK LIMITS,
PROJENG: MEF
2.
DISTURBED AREAS OUTSIDE TRAVELED WAYS SHALL BE STABILIZED IN ACCORDANCE WITH THE PLANS.
DRUMS ENG: ----
3.
ALL DISTURBED AREAS OR SLOPES SHALL BE RE -GRADED, COMPACTED, AND HYDROSEEDED AS DETAILED IN THE
DRAWN BY: JSE
SPECIFICATIONS.
SHEET TITLE
4.
THE CONSTRUCTION SITE, STAGING AREAS, STORAGE AREAS, AND MOBILIZATION AND DEMOBILIZATION ROUTES SHALL BE
RESTORED TO THEIR ORIGINAL CONDITIONS PRIOR TO CONSTRUCTION ACTIVITIES. ANY LEFTOVER MATERIALS SHALL BE
REMOVED FROM THE SITE. ALL EXCAVATED MATERIAL SHALL BE USED AS BACKFILL OR REMOVED FROM THE SITE AND THE
DESIGN CRITERIA
SURFACE PROFILE SHALL BE GRADED AS SHOWN IN THE PLANS. THE GROUND AROUND THE WELL HEAD SHALL BE SLOPED
AWAY FROM THE WELL AS SPECIFIED IN THE PLANS AND IN ACCORDANCE WITH ADEC REGULATIONS.
G-002
SHEET 2 OF 3
hero. icouA-T
oonnii"T. ___ n ___r_____ ----- A -11T. 101- rA oo 11- 1/„ /1m: n.:1.
3 OF 19 TOTAI SHFFT�
U
C
B
A
1
2
Pump Selection for a Pressurized System - single Family Residence Project
Platt Residence / Loma Est 131 L1
Parameters
Discharge Assembly Size
2.00
inches
Transport Length
30
feet
Transport Pipe Class
40
Transport Line Size
2.00
inches
Distributing Valve Model
None
Max Elevation Lift
11
feet
Manifold Length
18
feet
Manifold Pipe Class
40
Manifold Pipe Size
2.00
inches
Number of Laterals per Cell
4
Lateral Length
18
feet
Lateral Pipe Class
40
Lateral Pipe Size
2.00
inches
Orifice Size
1/8
inches
Orifice Spacing
3
feet
Residual Head
5
feet
Flow Meter
None
inches
'Add-on' Friction Losses
0
feet
Calculations
Minimum Flow Rate per Orifice
0.43
gpm
Number of Orifices per Zone
28
Total Flow Rate per Zane
12.1
gpm
Number of Laterals per Zone
4
% Flow Differential 1sULast Orifice 0.0
%
Transport Velocity
1.2
fps
Frictional Head Losses
Loss through Discharge
0.3
feet
Loss In Transport
0.1
feet
Loss through Valve
0.0
feet
Loss in Manifold
0.0
feet
Loss in Laterals
0.0
feet
Loss through Flowmeter
0.0
feet
'Add-on' Friction Losses
0.0
feet
Pipe Volumes
Vol of Transport Line
5.2
gals
Vol of Manifold
3.1
gals
Vol of Laterals per Zone
12.6
gals
Total Volume
20.9
gals
Minimum Pump Requirements
Design Flow Rate
12.1
gpm
Total Dynamic Head
16.4
feet
mot.
i
raoucnrc m[ wouos w�tto
200
180
160
140
om, 80
R
f
60-
40 -
20-
0 E
0
000
PumpData
3
5 10 15 20
Net Discharge (gpm)
P2005 HH Effluent
Pump Data
P2005 High Head Effluent Pump
20 GPM 1/2HP
115V 10
25 30
.oyo
System Curve:._
Pump Curve:
Pump Optimal Ranger
Operating PointP.
Design Point:`_
USER: JERHARDT PRODUCT: AutoCAD 2016 — English FILE: H:\jobs\18-021 anthc term contract 18—tc-161654 (anthc)\52 — well and septic designs — 2 anchorage homes\engineering\CAD\Drawings\General\ANC—G—STGENL.dwg LAYOUT: G-003
4
PRINTED: 7/11/2023 4:37:56 PM
0
® s
® v
0
Division of Environmental
Health and Engineering
4500 Diplomacy Drive
Anchorage, Alaska 99508
(907) 7293600
oe4 w:
#
0 1-
BAR IS ONE INCH ON
ORIGINAL DRAWING, IF NOT
ST SCALES ACCORDI
r_
Y J W
Qa>
LLI W CCW
ccCl) O
001,_
W
Ucc W
W
J=
L) Q
U
PROJ MGR: CJB
PROJ ENG: MEF
DRUMS ENG: ----
DRAWN BY: JSE
SHEET TITLE
PUMP SELECTION
CALCULATIONS
G-003
SHEET 3 OF 3
4 OF 12 TOTAL SH
•
e •
0
SANITARY SEWER
WATER
LINE LABELS
D
Division Environmental
Qs
SEWER MANHOLE
HYDRANT
WATER
Health and Engineering
4500 Diplomacy Drive
CO
CLEANOUT
P4 WATER VALVE
MS
WATER SERVICE
Anchorage,A69509
(907)729-36099508
vQ
SEPTIC VENT
WATER WELL
SANITARY SEWER
31;
©
SEWER LIFT STATION
Qw WATER MANHOLE
P : �Q
�0
SS
GRAVITY SEWER SERVICE
:e�' -
si
SEPTIC TANK
® WATER VALVE VAULT
CULVERT
ice= E!
®
ARCTIC BOX
THAW PORT
♦ s:, �:
��is
---------
BELOW GROUND SANITARY SEWER
...•• "e'
4��0������..•��•
05
SEWER VALVE VAULT
CONTROL VALVE
TOPOGRAPHY AND VEGETATION
--
FLOW DIRECTION
AIR RELIEF VALVE
O t'
220
MAJOR CONTOUR
—©-- EXPANSION JOINT
BAR IS ONE INCH ON
POWER AND COMMUNICATION
2Ie
MINOR CONTOUR
OIGINALIF NOT
ADJUST SCALESwACCORDINGLY
LIGHT POLE
C
SITE STRUCTURES
POWER AND COMMUNICATION
o
POWER POLE
�••-
QB BOLLARD
CATV-
CABLE TV BURIED
I"
©
ELECTRIC PED
d
fi FUEL TANK
FOR
GAS LINE
W
Q
EN
ELECTRIC METER
N LuPi
PROPANE TANK
-FO-
F[BEROPT[C BURIED
W L!1
E❑
ELECTRIC TRANSFORMER
N Q
© GATE POST
- OH/E -
POWER AND TELEPHONE BURIED
c
®
THERMISTOR
0In LL
® MONITOR WELL
LU
= � 0
®
TELEPHONE PEDESTAL
SITE
Z W n
THERMOSYPHON
Q r US
®
TELEPHONE BOOTH
X
FENCE LINE
Q N
SIGN
U
®
CABLE PED
to
® CATCH BASIN
®
ANTENNA
PB PULL BOX
F
z
QE ELECTRICAL VAULT
B
E6
FUEL POWERED GENERATOR
TOPO AND VEGETATION
Q
HYDRO POWERED GENERATOR
111- SLOPE ARROW
F
®
WIND POWERED GENERATOR
a•
TP -XX® TEST PIT
N
RUNWAY LIGHT
3y
o
SITE DRAINAGE
STREET LIGHT
WATER ELEVATION
TAXIWAY LIGHT
p�a RIP RAP
W
STRAW BALE
o
GRAVEL
ROAD OR DRIVEWAY
PLAN SET:AKA-21-ANC PHASE If
PROJ MGR: CJB
A
PROJ ENG: MEF
DRUMS ENG: ----
DRAWN BY. JSE
SHEET TITLE
CIVIL LEGEND
C-001
SHEET 1 OF G
USER: JERHARDT PRODUCT: AutoCAD 2016 — English
FILE: H:\iohs\18-021 anthc term contract
18—tc-161654 (anthc)\52 — well and septic designs
— 2 anchorage homes\engineerinq\CAD\Drawings\Civil\ANC—C—STLGND.dwq
LAYOUT: C—LGND PRINTED: 7/11/2023 4:38:11 PM
5 OF 12 TOTAL SHEETS
B
A
1 2
♦ \ ,/i I 1 , I I 29.1 s' � \
♦ I \ / ; ; IIS I� 41'30"W
\ \ \ I 1 1 1 , \ 1 \ ♦� �� \ , \ \ , I 0
-Ir
O
100 FOOT WELL ♦\ I I \\ \, /\\ \ \I \ \ \�� \\ \ 1 � � I III \�
SETBACK TO
SEPTIC SYSTEM♦
/ \N
l — l
♦ \ I I I I I, I 1 I I ,r //1 APPROXIMATE LOCATION \\
♦♦ ♦ I I I / ! ' / I 1 P h , (! 7 / II , OF GROUND WATER t— \
♦ III I I I / / / j 1 �� \� \ \ MONITOR TUBE/CULVERT .1W \
\ SET NEAR TANK. I \7 ¢
ry / / jl
^�
U) / 1 11 11 1\ \�
If)�
1 cO \ h( \\ ♦\ \\� Lu
\\ 1 I It
! 1 j 1 1 I �1 ANTHC TESTr \ �\ 5 .m \ ♦ \ \ \ \; In
I; I II �11j 1
tl PIT NO.1,� `� \` s COU L. 18' LONG SCH 40\ \ \
�I♦' I \ 2"0 PVC HEADER.
\ / / I 11 ` ♦ \ \ I VI I \I �, \ \ \\ \ I I
\\ I ! l ,! ! j I \ 1 1 ♦ R 3 0.0
A l \ I �I V 24' x 24' BED SOIL I I
ABSORPTION
\\ I
Oil I l j ,\ I j 'I SYSTEM (SAS)
I
HDL TP -01
\\ \ / I I I I IIII \ ` \ I I I I I I �'// ' ^ ♦-- (4) 18' LONG SCH 40 2"9+ /
PVC LATERALS SPACED
\ I —
\ 16' OC AND 3' FROM EDGE.
MONITOR TUBE
INSTALLED IN EACH__
IjlR30.0' / / CORNER OF SOIL
1 I I I I I /� I I I f l l
ABSORPTION SYSTEM
III it
ANTHC TEST
PIT NO.2 / \ 1 ��/\ t' 4�%'
i I I /\ �-,�^}^ \ \\ \ \\ l I 111
I'll ll / (\ \� \ \III I
i I'/ I f I� IY IILII I I I I I /Nil \
•I(t 6• —\ \ \
1 ; f ,�-(,-�I � ; ; ;111 I ; i ; ; 111 , I ; ; ; ; /; ; � ,{ 1 1, "'il � r -t y� \�. 1 , `\ `\ ; ; I • � � ! ; ; l ; , � _
L I I l l/ // // l l/_ /' 1 1 1288.31' /_ — i \k L, ! I, 1— 0 0 za'� +0'
\\�—ll ♦ I I 1 7�-11-1 /r 1 l 1 r��S89'49'21"W � — — �� I I ! l T
SITE PLAN - D. PLATT
Al 1--20•
USER: JERHARDT PRODUCT: AutoCAD 2016 — Enalish FILE: H:\iobs\18-021 anthc term contract 18—tc-161654 (anlhc)\52 — well and septic designs — 2 anchorage
r .n f =>� I
zi
SCOPE OF WORK/ NOTES:
•
1. PROVIDE NEW SEPTIC SYSTEM TO REPLACE THE EXISTING FAILING SEPTIC SYSTEM. EXISTING WELL • •
AND WATER SERVICE LINE TO REMAIN IN SERVICE. • .
2. INSTALL NEW 4" ABS SEWER SERVICE WITH 2" INSULATION BOARD ABOVE PIPE, AS SHOWN ON s e
SHEET SSSD-400. •
3. INSTALL NEW 1,500—GALLON SEPTIC TANK, EPDXY COATED STEEL, WITH LIFT STATION FROM
ANCHORAGE TANK. SEE CS -501 FOR SEPTIC TANK DETAILS.
Division of Environmental
4. INSTALL NEW PRESSURIZED BED SYSTEM AS SHOWN ON SITE PLAN AND PROFILE DRAWINGS, Health and Engineering
SHEETS C-101, C-102, C-103. 4500 Diplomacy Drive
Anchorage, Alaska 99508
5. PUMP—OUT, AND REMOVE THE EXISTING SEPTIC TANK. ABANDON EXISTING DRAINFIELD IN PLACE, (907) 72941600
REMOVE MONITORING PORTS. COMPACT, LEVEL, AND LANDSCAPE DISTURBED AREA.
6. PROPOSED FILL NOT SHOWN FOR CLARITY, SEE C-102.
C—SPHOME.dwq LAYOUT: PLATT PRINTED: 7/11/2023 5:32:52 PM
0 1.
BAR = ON
ORIGINAL DRAWING, IF NOT
J
YaW
Q
LLi�w
W
Q 0
0 N 00
W
fY
U W
a�W=)
U
r7)
PLAN SET.-AKA-21—ANC PHASE 11 1
DRAWN BY: JSE
SHEET TITLE
SITE PLAN - PLATT
C-101
SHEET 2 OF 6
6 OF 12 TOTAL S
I
I � (
I , �
I 1
� I I
1 X100—FOOT WELL SETBACK
1 TO SEPTIC SYSTEM
I 1 �
� 1 I
I 1
/ I
/ / I
/ V
/
I
I
1 1
1
1 I LG1
APPROXIMATE LOCATION
ABANDONED EXISTING
SS DRAIN FIELD
TH 1 I 1
I
11 i I11 I �
11I I
Y 0' I I 111 \ I
1
USFR- MFONDRFN PRODUCT: AutoCAD 2016 - English FILE: h:\iobs\18-021 anthc term contract 18-1c-161654 (an
NOTES
Q1 DO NOT EXCAVATE DRIVEWAY, REBUILD/REPAVED IF IMPACTED.
Q2 CLEAN OUT LOCATED IN CRAWL SPACE. ELEVATION AND LOCATION OF EXISTING
PIPE APPROXIMATE.
3. SLOPE PRESSURIZED SUPPLY LINE TO DRAIN BACK TO TANK (SEE SS -02)
® GRADE SITE SO DRAINAGE ON EAST SIDE OF SOIL ABSORPTION SYSTEM (SAS) IS
DIRECTED AROUND SAS TO THE SOUTH, AND DOWNHILL TO THE WEST
5. CONSTRUCT SAS A MINIMUM OF 6FT FROM EDGE OF ADJACENT FIVE WIDE TRENCH
SAS AND FIELD VERIFY PRIOR TO CONSTRUCTION
SEWER
SERVICE
ID
START
END
LENG
TH
SLOPE
DESCRIPTION
SS -01
0+22.03
0+32.64
10.6'
2.0%
4" SCH 40 ABS PIPE
SS -02
0+44.61
0+71.11
26.5'
1.0% MIN
2" SCH 40 PVC PIPE
SS -03
0+71.11
0+74.11
3'
0%
2" SCH 40 PVC PIPE
SWING TIE DATA
FROM
TO
DESCRIPTION
DESIGN
DISTANCE
AB
OA
Oi
PIPE CONNECTION (APPROX)
30.9'
©
Ot
PIPE CONNECTION (APPROX)
31.4'
QA
O2
NEW SEPTIC SYSTEM MANHOLE
36.5'
QB
O
NEW SEPTIC SYSTEM MANHOLE
42.4'
0
O
NEW SEPTIC SYSTEM MANHOLE
42.8'
Q
O
NEW SEPTIC SYSTEM MANHOLE
51.3'
QA
0
ELBOW AT BED SAS
69.8'
©
O
ELBOW AT BED SAS
73.7'
- well and septic designs - 2 anchorage homes\engineering\CAD\Drawings\Civil\ANC-C-SPPRFL.dwg
MAJOR STRUCTURES
ID
STATION
DESCRIPTION
CO 01
"A" 0+20.93
DOUBLE CLEAN—OUT, SEE SSD -301
ST 01
"A" 0+38.65
1,500 GALLON EPDXY COATED STEEL
SEPTIC TANK (ANCHORAGE TANK) WITH
LIFT STATION, SEE CS -501
SWING TIE DATA
FROM
TO
DESCRIPTION
DESIGN
DISTANCE
AB
QA
O5
NW CORNER BED SAS
67.7'
©
O
NW CORNER BED SAS
79.3'
QA
O
NE CORNER BED SAS
73.8'
0
O
NE CORNER BED SAS
69.8'
QA
O
SE CORNER BED SAS
96.2'
©
O
SE CORNER BED SAS
93.2'
QA
O
SW CORNER BED SAS
91.7'
QB
OB
SW CORNER BED SAS
100.5'
LAYOUT: PLATT PLAN PRINTED: 7/12/2023 9:06:53 AM
•
S
Division of Environmental
Health and Engineering
4500 Diplomacy Drive
Anchorage, Alaska 99508
(907) 72936DO
0 1-
BAR IS ONE INCH ON
ORIGINAL DRAWING, IF NOT
Y J W
aa>
wWw
<-
O D O Cn LL
W
U W
W
a� n
aLI)
U
U)
PLAN SET:AKA-2I-ANC PHASE 11
PROJ MGR: CJB
PROJ ENG: MEF
DRUMS ENG: ----
DRAWN BY: JSE
SHEET TITLE
PLAN - PLATT
C-102
SHEET 3 OF 6
7 OF 12 TOTAL SHEETS
NII♦
Z
O
I=
Q
w
J
LJ
3=
I
NOTES
Q1 GROUNDWATER LEVEL ASSUMED 7.75 FT BELOW GRADE.
O PROVIDE A MINIMUM 2.5 FT OF SOIL COVER OVER
INSULATION FOR FROST PROTECTION.
Q3 PLACE INSULATION OVER SEPTIC TANK SO IT EXTENDS 2.0
FT PAST EDGE OF SEPTIC TANK ON ALL SIDES.
® MONITORING TUBES SHALL BE 4" PERFORATED PIPE IN
SEWER ROCK, SOLID PIPE ABOVE SEWER ROCK, AND
CAPPED. THE BOTTOM OF THE PIPE SHALL BE LEVEL WITH
THE BOTTOM OF THE SEWER ROCK.
MAJOR STRUCTURES
ID
STATION
DESCRIPTION
CO 01
"A" 0+20.93
DOUBLE CLEAN-OUT, SEE SSD -301
ST 01
"A" 0+38.65
1,500 GALLON EPDXY COATED STEEL
SEPTIC TANK (ANCHORAGE TANK) WITH
LIFT STATION, SEE CS -501
I
1
GRADING TABLE
ID
DESCRIPTION
ELEV
AB
A
SEPTIC TANK (BOTTOM)
628.87'
650
B
TANK BEDDING (LOWER)
627.87
C
COVER / FILL, GRADE TO DRAIN
VARIES
D
FINE GRADE SEWER ROCK (LOWER)
634.0'
E
FINE GRADE SEWER ROCK (UPPER)
635.17'
o
F
TOP OF SAS PIPING
635.0'
(. o I,- 'I
650'
1 DD
650
2ND
FF
o
0
ELEV=
of
1
645.7'
0
to
4" PVC MONITORING
TUBE IN EACH
EG_
-
CORNER, SEE NOTE 3
2" INSULATION OVER ENTIRE 24'X24'
_ _ _ _
_ _
(TYP OF 4)
BED SOIL ABSORPTION SYSTEM
2" INSULATION
4' RISERS
2" INSULATION
SEE C102 FOR PLAN VIEW
-
-��
\���
24" WIDE OVER
SUPPLY LINE C
640'
Q3
640'
1ST FF
ELEV=
FG
EG
-
-
—1 2 -L
4- 3FG i
_ _ _ _ --
- -°— —
I fiiT�� ISI
M
<
639.7
-
--
-
--
--
-
--
I
1 1 I "� >'s�? ',�c�',
"�,�",✓^2 _ "^
-DSI
cm
SS -)2 I
2" LATERALS SCH
2" SCH 40 PVC 40 PVC 18' LONG
-
I 14" SEWER ROCK
D
OZ
SS -01
_ _ - _
I
T -
I
SUPPLY LINE_
MIN 2" ABOVE
630'
SLOPED TO DRAIN WITH 1/8 HOLES
i - -
630'
I
' I
_ _ _
' - _ _
BACKTOTANK _
_ _ _ I_ _ TOP OF PIPE
_ 4
_ -
64" DIAMETER
AND
APPROXXIMATELY 3'
10' LONG TANK
APART (7 HOLES
4 CONCRETE ANCHOR
1
A�
BLOCKS APPROXIMATELY PER LATERAL)
B
I 2'(W)x4'(L)x2'(H) WITH
STAINLESS STEEL STRAPS.
TANK PROTECTED WITH
RUBBER STRIPS UNDER
CABLE.
I
i
I ( I
620'
620'
ID
�J
1.1
1:1
I:i
VI
W
W
1.1
i:i
17�'
0+00 0+10 0+20 0+30 0+40 0+50 0+60 0+70 0+80 0+90 +
4
PROFILE - D. PLATT
Al 1-_4.
I
USER: MFONDREN PRODUCT: AutoCAD 2016 — Enalish FILE: H:\iobs\18-021 ANTHC Term Contract 18—TC-161654 (ANTHC)\52 — Well and Seatic Designs — 2 Anchorage
C—SPPRFL.dwg LAYOUT: PLATT PROFILE PRINTED: 7/12/2023 2:18:36 PM
• o
0
Division of Environmental
Health and Engineering
4500 Diplomacy Drive
Anchorage, Alaska 99508
(907) 7293600
w ¢ g
pis'••" �
s
�♦/ *.0.E; .'�
O 1
BAR IS ONE INCH ON
ORIGINAL DRAWING, IF NOT
IDJUST SCALES ACCORDINGLY
ob Z
Z
LLI U
Q Q �
F-
N
4Lu Z
j=r—
CC � J U
=oaX
W
Z0 O
QLLJ Lou
U �
N N
PROJ MGR: CJB
PROJ ENG: MEF
DRUMS ENG: ----
DRAWN BY: JSE
SHEET TITLE
PROFILE - PLATT
C-103
SHEET 4 OF 6
8 OF 12 TOTAL SHEETS
Al
M1
31
C-�) 0 .1
NOTES
Q1 GROUNDWATER LEVEL ASSUMED 7.75 FT BELOW GRADE.
O SLOPE WALLS AS REQUIRED FOR SAFETY.
3. CONTRACTOR SHALL NOTIFY THE ENGINEER AND ANTHC 24 HOURS
PRIOR TO EXCAVATING FOR THE INSTALLATION OF THE SYSTEM TO
VERIFY SUBSURFACES MEET MOA REQUIREMENTS; TO COORDINATE
DOCUMENTATION FOR SUBMITTAL.
4. CONTRACTOR TO CONSTRUCT BED SOIL ABSORPTION SYSTEM WITH OUT
TRACKING EQUIPMENT OVER SOIL ABSORPTION SYSTEM.
6' MIN VERTICAL SEPARATION TO
IMPERMEABLE SOIL OR BEDROCK
a TYPICAL LEACH FIELD SECTION - D. PLATT
AlN.T.S.
IICFP- .IFPPAPr)T PPnl)llfT• A,il..r An gf11R G71 r. —1h, Ia.... —Ir...•! 1R--1n1RSd well —A —N, A..i— — 9 —h-- A— I AYnl]T• PI GTT CFrTION PRTNTFn- 7/11/9n9; 4.4r-01 PIA
Division of Environmental
Health and Engineering
4500 Diplomacy Drive
Anchorage, Alaska 99508
(907) 7293600
0 1"
BAR IS ONE INCH ON
'.GINAL DRAWING. IF h
ad Z
Z 0
J U
Q Q �
r F --
N
W Z
O
= w
z� O
a� w
a �
U fn
U) N
PLAN SET:AKA-21-ANC PHASE 11
PROJ MGR: CJB
PROJ ENG: MEF
DRUMS ENG: ----
DRAWN BY: JSE
SHEET TITLE
SECTION - PLATT
C-301
SHEET 5 OF 6
■
NOTES:
1. MEASURE FLOATS FROM CENTER OF TEE HANDLE ON
D 9 15 FLOAT STEM
P �( I 2. ORENCO FLOAT SWITCHES — MODEL P (HIGH LEVEL
B ALARM) AND MODEL B (ON/OFF).
FLOAT SETTING DETAIL
131 N.T.S.
■
al ANCHORAGE TANK 1500 GALLON STEEL TANK WITH LIFT STATION PACKAGE
Al N.T.S.
Cb 0 Z
NOTES:
1. SEPTIC TANK AND SEPTIC TANK EFFLUENT PUMPING (STEP) SYSTEM DETAIL FROM
ANCHORAGE TANK. DIMENSIONS ARE IN INCHES. FOR MORE INFORMATION ON LIFT
STATION AND STEP SYSTEM COMPONENTS REFER TO ANCHORAGE TANK
INSTALLATION MANUAL.
2. FLOAT SYSTEM AND CONTROLS TO BE WIRED BY QUALIFIED ELECTRICIAN IN
ACCORDANCE WITH ANCHORAGE TANK INSTALLERS MANUAL
3. STEP CONTROL PANEL TO HAVE AUDIBLE AND VISUAL HIGH LEVEL ALARM
4. ORENCO P2005 PUMP OR EQUAL SPECIFIED FOR DESIGN
5. DISCHARGE WILL BE 2" VALVE & HOSE NOT HANGING DISCHARGE SHOWN.
6. TANK HAS BEEN SET BY CONTRACTOR. BEDDING MATERIAL PLACED 1' BELOW TANK
AND ON SIDES TO TOP OF THE TANK - DUE TO SATURATED SOILS AT TIME OF
INSTALL.
7. INSULATE AND BACKFILL SEPTIC TANK AS SHOWN ON PROFILE SHEET.
INSULATION TO EXTEND 2' PAST EDGE OF TANK ON ALL SIDES.
SEPTIC TANK MATERIALS OF CONSTRUCTION:
• FABRICATE FROM 10 GAUGE STEEL.
• SANDBLAST & COAT W/DEVOE BAR -RUST 235 OR 236 (EPDXY COATING).
• SEAL WELD ALL INTERIOR SEAMS.
FLOAT SETTINGS TABLE
INSULATED FIBERGLASS
A
43" PUMP OFF
B
47" PUMP ON
C
RISER LID—ORENCO
D
56" RESERVE
DOSE VOLUME
FLD 24 G [ 4
RESERVE
JABOVE HIGH LEVEL ALARM IS APPROXIMATELY 96 GALLONS
C
ORENCO 24" RIBBED
RISER W/ 4" FOAM
2" VALVE & HOSE DISCHARGE TO BE
INSULATION &
REQUESTED FROM ANCHORAGE TANK
48"
COAL TAR TOP COAT
(DIFFERENT THAN HANGING DISCHARGE SHOWN)
24" 4 SLIDE OVER
4" ABS
15" MANHOLE
FROM HOME
JIM CAP TO
7
4
_ r,
SEAL OFF 2„ DIAMETER SCH 40
�_'j
TANK OUTLET
PVC SUPPLY LINE TO
SOIL ABSORPTION SYSTEM
INLET PIPING
I
±!'
OUTLET PIPING
3 BY TANK MFR.
i;
REMOVED
BAFFLE
464"
PIPING
BY
D TANK
C B MFR.
A
37" J
�'I
'}
ANCHORAGE TANK
SEPTIC TANK EFFLUENT
BAFFLE
PUMPING (STEP)
SYSTEM PACKAGE
SEE SHEET G-003
FOR PUMP INFORMATION
80"
40"
120"
al ANCHORAGE TANK 1500 GALLON STEEL TANK WITH LIFT STATION PACKAGE
Al N.T.S.
Cb 0 Z
NOTES:
1. SEPTIC TANK AND SEPTIC TANK EFFLUENT PUMPING (STEP) SYSTEM DETAIL FROM
ANCHORAGE TANK. DIMENSIONS ARE IN INCHES. FOR MORE INFORMATION ON LIFT
STATION AND STEP SYSTEM COMPONENTS REFER TO ANCHORAGE TANK
INSTALLATION MANUAL.
2. FLOAT SYSTEM AND CONTROLS TO BE WIRED BY QUALIFIED ELECTRICIAN IN
ACCORDANCE WITH ANCHORAGE TANK INSTALLERS MANUAL
3. STEP CONTROL PANEL TO HAVE AUDIBLE AND VISUAL HIGH LEVEL ALARM
4. ORENCO P2005 PUMP OR EQUAL SPECIFIED FOR DESIGN
5. DISCHARGE WILL BE 2" VALVE & HOSE NOT HANGING DISCHARGE SHOWN.
6. TANK HAS BEEN SET BY CONTRACTOR. BEDDING MATERIAL PLACED 1' BELOW TANK
AND ON SIDES TO TOP OF THE TANK - DUE TO SATURATED SOILS AT TIME OF
INSTALL.
7. INSULATE AND BACKFILL SEPTIC TANK AS SHOWN ON PROFILE SHEET.
INSULATION TO EXTEND 2' PAST EDGE OF TANK ON ALL SIDES.
SEPTIC TANK MATERIALS OF CONSTRUCTION:
• FABRICATE FROM 10 GAUGE STEEL.
• SANDBLAST & COAT W/DEVOE BAR -RUST 235 OR 236 (EPDXY COATING).
• SEAL WELD ALL INTERIOR SEAMS.
. evnn . o. - nv ooi1111 /ono¢ n. en ou
•
e
• � s
e •
0
Division of Environmental
Health and Engineering
4500 Diplomacy Drive
Anchorage, Alaska 99506
(907)729.1600
P+
00
7Q_ s
•v,.��;:
11 .k•pEG�•.�
0 1'
BAR IS ONE INCH ON
Is
w
aa>
L U W CC
W
Er
xU)0
013 LL
W
U
CC W
W
CC N
Q
U
U)
ASE U 1
PROJ ENG: MEF
DRUMS ENG: ----
DRAWN BY: JSE
SHEET TITLE
SEPTIC TANK DETAIL
CS -501
SHEET 6 OF 6
FLOAT SETTINGS TABLE
(MEASURED IN INCHES FROM BOTTOM OF SEPTIC TANK)
A
43" PUMP OFF
B
47" PUMP ON
C
52" ALARM ON
D
56" RESERVE
DOSE VOLUME
JAPPROXIMATELY 121 GALLONS
RESERVE
JABOVE HIGH LEVEL ALARM IS APPROXIMATELY 96 GALLONS
. evnn . o. - nv ooi1111 /ono¢ n. en ou
•
e
• � s
e •
0
Division of Environmental
Health and Engineering
4500 Diplomacy Drive
Anchorage, Alaska 99506
(907)729.1600
P+
00
7Q_ s
•v,.��;:
11 .k•pEG�•.�
0 1'
BAR IS ONE INCH ON
Is
w
aa>
L U W CC
W
Er
xU)0
013 LL
W
U
CC W
W
CC N
Q
U
U)
ASE U 1
PROJ ENG: MEF
DRUMS ENG: ----
DRAWN BY: JSE
SHEET TITLE
SEPTIC TANK DETAIL
CS -501
SHEET 6 OF 6
�' Q 0 1
7 L 3 4
5'-0" MAX /
•
o -
G 'I • o
I
D OPTION 1: / HOUSE
USE ARCTIC BOX IF Division of Environmental
SEWER CONNECTION I Health and Engineering
FERNCO CAP I IS ABOVE GRADE I 4500 Diplomacy Drive
I I Anchorage, Alaska 99508
I (907) 729-3600
-1 T T r -
I I I I
I I I
I I WALL FINISH
4" PVC I I I FLOOR
2'-0" SCH 80
RISER I I I I I
EXISTING I I I I
GROUND I I I I I
I I I I I
[11111111
111111111111111111111111 HIM 111111111111111111111111111111111 HII 1 111111
I I I I I
III—III—III i-1 I I_i I I_i i I—I I H I i .III—i 11=1 11=1 I H I 1=1 I(=1 11=1 11=1 11=1 1=1 11=1 1=1 11=1 1=1 1=1 I(=1 11=1 11=) I i =1 11=1 1=J I I—III—I I i_I I I—I 1=f I I- I f=1 11=1 11=1 11=1 11=1 11=1 11=1 I-1 I I r -I i 1=! ! I-
=1 I-1 11=1 11=1 I=1 1=1 11=1 1=1 11=1 f =1 1=1 11=1 11=1(1=1 11=1
III 11=1 11=1 11=1 1=1 1=1 1=1 11=1 11=1 11=1 1=1(1= I I I=1 11=1 11=1 I I=1 III=1 11=1 11=1 I I-1 11 I I E=1 11=1 11=1 I I-111=1 I I -I 11=1 11=11—=1 11=1 I
I I I—I 11=I I IIS i 1=1 11=1 1=1 11=1 ! I� I f- 11=(I 1=1 11=1I h I I=1 11=! 11=1 11=1 I I� 1=1 11=1 1=1 1=1 I� 1=1 11=1 I!=1 f 1=1 I i —I 11=1 f=1 I—I i ISI 11=1 11=1 1=11—; 11=1 11=1 1=1 11=1 11=1 11=' 11=, I)=1, I_rl 1=111=1 I
CRAWLSPACE o ,
=1� III=1I 1=III=1 11=I 11=I 11=1 I I=1 f =1 11=(I 1=�=1 11-T=1 11=I 11=1I I=1 I I-1 I I=I 11=I 11=1 11=1 I L^T=1 I�—_I I ITI I I— T—�I LI I f-1 11=1 I =I I �I I =f I I—�1= I I L=III=III=1 11=1T=1 f CONCRETE BLOCK I�< �
BAR IS ONE INCH ON
III -1 ! 1—III— ORIGINAL DRAWING, IF NOT
–�-—� ADJUST SCALES ACCORDINGLY
SEE SEWER SERVICE
TRENCH DETAILS I —III—III CLEANOUT CAP, SECURE
(; FOR BEDDING AND WITH ALL METAL HOSE r
4' MIN BACKFILL REQUIREMENTS I OPTION 2: I I—I I (—III. CLAMP (FERNCO QWIK F-
4" PVC SCH 40 THROUGHI I—III= _^ CAP OR APPROVED EQUAL)
STEM -WALL PENETRATION I 1—I I (—III STUB OUT 0
11=1 I F .'.'. 1' MIN z
RIGID HAZARD I I—III—III ' ABOVE GRADE Q
TAPE 1' 0" -! !— — , J
INSULATION 6"
z %SLOPE MIN
TO SEPTIC TANK HE=; 1 ! !-1 !—! I—! I I� I—III—� I-1 I I -I-1 I I—! ! !—I I—III—! ! !—I I—I ! o W
OR SEWER MAIN I I— I� I I—III—I 11=1 11=1 11=1 I I- I I I-1TI=1TI� 11=1 11=1 1=1 11=1 I I� 11= z a
WW
I U Q
I OPTION 3: g0° FITTING (TYP)
(IF DOUBLE) I (IF SINGLE) W
TO SEPTIC TANK PVC SANITARY WYE RUN SEWER SERVICE
OR SEWER MAIN LINE UNDER FOUNDATION fn
WALL AND FOOTER
W
W
�1 SEWER SERVICE - ABS PIPING C/)g o i 1" =1'-0"
PENETRATION NOTE:
LOCATION OF PENETRATION SHALL BE APPROVED BY HOME OWNER 0/ STDA TDRD
AIL
AND FIELD VERIFIED TO ENSURE PROPER LOCATION. PENETRATION TO iE ' VERSION t.o
BE CLEANLY CORED OR DRILLED.
1/2" PLYWOOD CONCRETE
STEM WALL
BITUTHANE SHEET a z 2 w o¢ cwi 1,
COVED AROUND SPRAYED CAST/CORE _ O - _ z _ w> wo
PIPE, SEAL WITH LOW -EXPANDING DRILL<mz L
ED HOLEO u=
BITUTHANE MASTIC URETHANE "x: y`.. / CRAWL w O� z o o' o z o=
�/ SPACE 0F=0� <Ci
------------ INSULATION w< -= Oa -wJaoZci
/ w m w
rod¢=0:0w�~r¢,a
SPRAYED �w'da>0i�0¢00
LOW -EXPANDING w o¢ a_¢ N z
URETHANE za¢Ww�gaa3�
----------_ / -- -- INSULATION zFo,�-0O<10
4 INSULATE _ __ ww=Z~o}2F
'• k '.. w w LL N U, w N m Z O o
WITH
SPRAYED ym OS ¢u_ww<J�
CRAWL t LINK SEAL W/ BOLTS wok =gym 0 z >
URETHANE �arrwwow dw
SPACE INSULATIONELASTOMERIC SEAL ¢ 3 0 a z o' y¢ w
ELEMENT LS MODEL z °x z w, w o
WIDTH 11 I (C, L. S-316, - u, gM w m <
VARIES T l O, OS -316, T)
(LINK SEAL)
A3 WOOD PENETRATION A4 CONCRETE PENETRATION SSSD-301
SHEET 1 OF
USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2021-Enalish FILE: P:1 Eno Reitz Restricted Accessi Scattered Sites LihraMSSD-C-DTSSWR.dvm LAYOUT-SSSD-301 SEWER SERVICE AND CLEANOUT -ABS PIPE PRINTED:72020223,05,52 PM
0
A
B
1 1 2 1 3 I
OPTION 2:
2" SCH 40 PVC PIPE FOR PRESSURIZED SEWER LINE - MIN 2' OF SOIL COVER AND INSULATION
NOTE: PRESSURIZED SEWER LINE TO SLOPE BACK TO TANK
SEWER TRENCH DETAIL - ABS OR PVC PIPE
/11 314"=1'A"
:R: MCYANDELL PRODUCT: Autodesk Civil 3D 2021 - English FILE: P:1_Eng_RefVz_Restricted _Accessl_ Scattered _ Sites_ LibmiytSSD-C-DTRNC.dwg LAYOUT: SSSD-400 SEWER SERVICE LINE TRENCH PRINTED: 7202022 3:06:46 PM
rt-a� 1q- I
4 - -
gOTES:
1. SEE SPECIFICATION FOR ADDITONAL EARTHWORKS REQUIREMENTS.
•
2. SEE SPECIFICATION FOR SEEDING REQUIREMENTS. .
O 4" MIN GRAVEL LEVELING COURSE, COMPACTED, IN DRIVEWAYS AND e
ROADWAYS ONLY.
® 12" TOPSOIL OVER COMPACTED FILL, 12" OVER SURROUNDING GRADE,
RAKED SMOOTH, MOUNDED AND LANDSCAPED WITH GRADE AND
FERTILIZED, EXCEPT NEAR HOME. MOUND SHOULD SLOPE WATER AWAY Division of Environmental
FROM HOME. Health and Engineering
4500 Diplomacy Drive
O5 LIMITS OF EXCAVATION, TYP. MINIMUM SLOPE OR PROTECTIVE SYSTEM AS Anchorage, Alaska 99506
REQUIRED BY OSHA - BASED ON SOIL TYPE AND CONDITIONS 1 112:1 (907) 7293600
SHOWN FOR TYPE C SOILS FOR REFERENCE.
0 1"
BAR IS ONE INCH ON
ORIGINAL DRAWING, IF NOT
U
Z
W
Q'
I—
W
Z
I
W
U
W
U)
w
W
W
U)
I STANDARD I
DETAIL
VERSION 1.0
>2
yO�zjw0=
�Wy(9C(nC0
F, G<Omw ZNUi
O Z LL z~ LL z~ W
w0—ZF-<OZO2
KQOO�a0ZUZ1-
n-O�F ¢�tnwx6x
w�Y�xO=fir>U_'
x oag_ZgqTrnO r�Z�2
j d
OrYz-�wOwZ OrO
W a m O U N Q O
w0�¢aq¢z¢iryz
zdta W W �gQd3j
wwZ OaOog�
wrW<o< zz
Opwz¢¢l,ow FFriwovi
W.WP.Mwo>.zO=
Nm OQ N�+-aW� jK
wz0=~m UQa:¢w
w= aW a,.Oz Owa1SQ¢
r0zw
~MF=j.q
ZZzwmw
owz
�N.S W.,
SSSD-400
SHEET 1 OF 1
4500 Diplomacy Drive
Anchorage, Alaska 99508
(907) 729-3600
D
A
B
C
1 2 3 4
Division of Environmental
Health and Engineering
G-003
3 4
SOILS INFORMATION -
PLATTANCHORAGE, AKSCATTERED SITES- ALLEN &PLATTISSUED FOR CONSTRUCTIONTH#1 SOILS LOGC1NTS
TH#1 MUNI SOILS LOGC2NTS
EXISTING SYSTEM DESIGNA3NTS
TH#1 PERCOLATION TESTC3NTS
TH#3 PERCOLATION TESTA1NTS
D
D
4500 Diplomacy Drive
Anchorage, Alaska 99508
(907) 729-3600
D
A
B
C
1 2 3 4
Division of Environmental
Health and Engineering
V-101
1 1
SURVEY PLOT PLANANCHORAGE, AKSCATTERED SITES-DONNA PLATISSUED FOR CONSTRUCTIONSITE PLANA11" = 30'
49THSTATEO F ALA
S
KAPAUL RUSSELL
LS-14430REGI
STEREDPROFESSIONA L LANDSURVEYOR8/31/2022
Municipality of Anchorage page / of 2 -
DEPARTMENT OF HEALTH AND HUMAN SERVICES
DEPARTMENT
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SW930390 PID Number: 0z00gzz9
Name.
CHERYL S17`05-77—
HCIZAddress:
Wastewater System: Ls3 New ❑ Upgrade
Address:
ABSORPTION FIELD
p2 009229000?Y'
Phone:
No. of Bedrooms
:hone: 70
3
Deep Trench Shallow Trench ❑ Bed ❑ Mound ❑ Other
LEGAL DESCRIPTION
Soil Rating:
Total Depth from original grade:
O. 6 GPD/Sq. Ft.
G
Lot: Block: Subdivision:
Depth to pipe bottom from original grade:
Gravel depth beneath pipe
/0,06a.4 ES7-47-6S
3 Ft.
3 Ft.
Township:
Range:
Section:
Fill added above original grade:
Gravel length:
o - / Ft.
93 Ft.
WELL: ❑ New ❑ Upgrade
Gravel width:
5"
Number of lines:
z
Distance between lines:
1 /6
Ft.
Ft.
Classification (Priv te, A,B,C):
Total Depth:
Cased To:
Total absorption area:
Pipe material: 0303y
- -
FL
Ft.
SQ. Ft.
45rM F id o PE',21=•
Driller:
Date Drilled:
Static Water Level:
Instal er: /
Date installed:
Ft.
�•�L/
/o -/3-93
Yield:
Pump Set at:
Casing Height Above Ground:
TANK
GPM
Ft.
Ft.
SEPARATION DISTANCES
0 Septic ❑ Holding ❑ S.T.E.P.
To
Septic
Absorption
Liu
Holding
Public/Private
Manufacturer:
Capacity in gallons:
From
Tank
Field
Station
Tank
Sewer Lines
4A)cHaR_,466 7;;w k-
4z! o
Well
—.
,_,
Z$i f,
Materials EEL
Number ofCompartments:
SurfacWater
/00'1/-
/oo '4
—
—
LIFT STATION
Lot
,
�Size
in gallons:
acturer:
Line
/0
/O
--
—�
Foundation_•
21i t
1.12 `
__
"Pump on" level at:
"Pump ofY a
High water alarm at:
Curtain
NDN
,e.N
W.V
Pump Make & Model
Electrical Inspections performed by:
Drain
Remarks:
BENCH MARK
lQJELL �� �2�c_c g7) Al
Location and Description: Off.
ioP av c. rh, u. ui4« 44 Al�i4T!
Assumed Elevation:
/dU . O
ENGINEER'S SEAL
S
17034 Eagle River Loop Road, No. 204
Inspections performed by: Eagle River, Alaska 99577 Dates: 1 st /o -// -93
2nd /o - -93
Department of Heal nd Human Services approval
/y ��'
Reviewed and approved by: / Date:
72-013 (Rev. 9/91) MOA 25
Permit No. SW930390 Page 2 Of 2
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 e Anchorage, Alaska 99519-6650 * Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: LOMA ESTATES, BLOCK 1, LOT 1 PID No.: 02009229
Col CO2
95.4"
C05
C06 MTS
MT2
W
NEW
89.5
.0. ..... 0 ..................
1 0 GAL
.... ............. .............
........ ......... ............
.......
............. ...........................
. . ........ ..........................................
S.T.
88.6a; R
R
N.T.S.
........... ....................... I
...... ...................................
......................................... I ...... ..................................
.............................._85:3'...................
. ... . ......... .... .. .. ... . .
A 79.3'
NO WATER FOUND
B
.......... ......... .. . ......
A
FCO
15.0
10.0
COI
25.5
45.0
CO2
33.0
50.5
CO3
45.0
58.0
C04
62.0
74.5
C05
79.5
76.0
a
We—
z5z_
'59za
............. ................. ....... a ........... ......
NEW ... DRAINFEILDS
...............
.............
MT1
60.5
57.5
MT2
75.0
174.5
C05
G 6
MT2
MT1 o
..................................... .
..................................
....... ............
....... ....... .....
. ...... .... ........ .. . ...................... . .........................................
WALL
B
co 03
FCO
C
3 BDRM
DHL CO:
.-Col ...
......
ENGINEERS SEAL
NEW 1250 GAL
SEPTIC TANK
SCALE 1" = 40'
w
4 1 x
t t*0143** *
(S
C
Pon
C
B*P"
"now
on"
4)
O
fn
RECEIVED
MAR 7 1994
Municipaliq of Anchorage
Dept. Health & Human Services
51
ot
i
P -i
Pi
f
qq;,
00 OD;
U*11 in
-04 E�l
Ed4 1,64
P'
Ln! in gf;:
14 �k
UA
I it
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW930390
DESIGN ENGINEERS & S ENGINEERING
OWNER NAME:FISHER CHERYL F
OWNER ADDRESS: 0200922900088
PARCEL ID:02009229
LEGAL DESCRIPTION: LOMA ESTATES BLK 1 LT 1
LOT SIZE: 63302 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
PAGE 1 OF 1
'Qnm
o- 1113
12.1,00 Pyvk
1c) -1 3 , 413
DATE ISSUED: 9/22/93
EXPIRATION DATE: 9/22n/94
to-►S�y�
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY:
DATE:
ISSUED BY: / DATE: Z L
Fj-
HEALTHAUTHORITY
APPROVALS
September 16, 1993
unicipality of Anchorage
EPARTMENT OF HEALTH AND HUMAN SERVICES
25 L Street
SEWER & ER
MAIN EXTENSIONS nchorage, AK 99519-6650
SEWER&WATER EFERENCE: Loma Estates Subdivision, Block 1, Lot 1
INSPECTION
ROBERT SHAFER, P.E.
ROGER SHAFER, P.E.
CIVIL ENGINEERS
(907)694-2979
FAX 694-1211
e request you issue a permit to drill a well and install a
ENGINEERING STUDIES geptiC system to serve the proposed three bedroom house on
AND REPORTS
he referenced property.
o test holes were excavated and percolation tests performed
WELLINSPECTION n the property. The approximate location of the test holes
&FLOW TEST re located on the attached site plan. The test holes have
teen checked and found to be dry.
Phis property has enough area for a future septic upgrade,
SITE PLANS vhich can be seen on the attached site plan. We do not
anticipate any adverse effects on neighboring properties by
he installation of the proposed septic system.
ROAD DESIGN f you have any questions, or require additional information
or your review, please contact us.
SOIL TEST
o`l�ert A. Shafer, P.E.
PERCOLATION
TEST
S/LSU/lsu
STRUCTURAL&
MECHANICAL
INSPECTIONS
ONSITE
WASTEWATER
DISPOSAL SYSTEM
DESIGN
17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577
7 Z�YIKL
i
1V a
i I
� I
LO z
I
oLLJ U)
E,
co Z
Q� F- (n O
W 7- O Z
l x C7 = 0 z a W OAS I
W \� z �Wa co // a°c)
o w =)I-> o o' w
M � oaQ U) Op o
rn ���� F- �oX Awa/
J (Dd c°r-w >v `n� r P, cn P�
II
oil
7 0)TTekk Il����iidwwZ ��o
w v p F� w01, O Q r
V) / O
r MM W— b- J Z 04
< G
2i w O m:t o O / a E-
M—J
10 V) � � (D � ro 00 00 d � '� P. m $ Z I w
0
0 H I W
-- P E+ I F-
E,
O W
I
O
-a o z `2 I w
vi zz moo
_ 0 LLI o i w
%� aN C) 2: o Q� o m
VlV 0
0 V Q W W =
zw�-V)=ow
-aa U wpm r0�Z O
-� Q�Q z C.D L,E5D tk
0zQZOO>-
Z--4 ra0wl= I
W Z >J(nd
=w W m r 0 E I
J w0w((nz Wd / u� I I
N t rZOf 6
W
.,� J — W r
V1 V I
VzV)`'-rwz� - I
Q �a to>a
Oz
0
I
I
s
4
V• U
�e 3ltlJS
NVId 311S 09 = IIS
Municipality of Anchorage
t DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST }
PERFORMED FOR: HEEIL E-ISOE& DATE PERFORMED: fin /73
LEGAL DESCRIPTION: /0� 5/P4Li It Township, Range, Section:
DEPTH SLOPE SITE SITE PLAN
(FEET)
h ^ a2(rf1NICS
1 -A _
—Siczy Sawn N
2 U I I I I I I I I I I I -��
3 P d�
< C.
4 �� <
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
SSw - 6aftoi o sty
ML- _ I16wl err r "rA2GUwoa7
6 Gti/
fl A11 11411 1 'El
WAS GROUND WATER NO ENCOUNTERED? V v
S
L
IF YES, AT WHAT '— 0
DEPTH? P
E
Depth to Water After
Monitoring? Date: a �3
Reading Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
ai '
I N
3/cy
14"
Am mIU f�-,
e-
I I "
—
S3/
�r
t1ir
S1
9-
yZ
20I I PERCOLATION RATE 4- (minutes/inch) PERC HOLE DIAMETER C ' _
u TEST RUN BETWEEN FT AND 2 FT
COMMENTS k� 7EO 22 S17E, w r �� �(tN `-0
S & S CNGINEERING CERTIFY THAT THIS TEST WAS PERFORMED IN
PERFORMED M770 age Rjvbr Loop Road NO. 204
ACCORDANCE-QQIP¢ MVef,TAM�J9 ICIPA .GUIDE E FFECT ON THIS DATE. DATE:
e Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
�1�i� }-�St(z
PERFORMED FOR: � DATE PERF
LEGAL DESCRIPTION: I-0/tIft -/%/ w / f . ISL.. 1
DEPTH
(FEET)tc 01Z&
1
Ox.�SdLCw-
2ff��
ShO�— — Stc l y SAID
3
r 7-) 4 i — 'F ,-lz_ (70 � t' 7
9
10-
12
0 12 to, t4-
13
14
15
16
17
18
19
Township, Range, Section:
WAS GROUND WATER
ENCOUNTERED? ,v
S
IF YES, AT WHAT L
0
DEPTH? P
E
Depth to Water After �2 g i3
Monitoring? Date:
dp I JI I C rLHIV
MEMO, TF 0W wom0®v
6
G ,I
j
a
9
10-
12
0 12 to, t4-
13
14
15
16
17
18
19
Township, Range, Section:
WAS GROUND WATER
ENCOUNTERED? ,v
S
IF YES, AT WHAT L
0
DEPTH? P
E
Depth to Water After �2 g i3
Monitoring? Date:
dp I JI I C rLHIV
20 -{ ��
IL— JI PERCOLATION RATE (20 (minutes/inch) PERC HOLE DIAMETER
p.�� TEST RUN/B�ETW— �"EEN 1'S FT AND 15 }SFT
COMMENTSUSE x SHfl"Ub ` —&-V &412E L.�` I•JI 'IN i'IRJ. ),
Gt So fc_S 1150116 , C _ 2SO SE f
PERFORMBE&PT:E��NGIN6ERINGRTIFY THAT THIS TEST WAS PERFORMED IN
(
ACCORDA d E tPbW. MgldP4WJIDEES FFECT ON THIS DATE. DATE:
Eagle River, Alaska 99577
MEMO, TF 0W wom0®v
20 -{ ��
IL— JI PERCOLATION RATE (20 (minutes/inch) PERC HOLE DIAMETER
p.�� TEST RUN/B�ETW— �"EEN 1'S FT AND 15 }SFT
COMMENTSUSE x SHfl"Ub ` —&-V &412E L.�` I•JI 'IN i'IRJ. ),
Gt So fc_S 1150116 , C _ 2SO SE f
PERFORMBE&PT:E��NGIN6ERINGRTIFY THAT THIS TEST WAS PERFORMED IN
(
ACCORDA d E tPbW. MgldP4WJIDEES FFECT ON THIS DATE. DATE:
Eagle River, Alaska 99577
1
r RUSH! ,
• Municipality of Anchorage
On -Site Water and Wastewater Program
(907)343-7904
Certificate of On -Site Systems Approval q -7
Parcel I. D. 020-092-29 Expiration Date: f - 1! /
1. GENERAL INFORMATION
Complete legal description Loma Estates Block 1 Lot 1
Location (site address) 16910 Bettijean St, Anchorage AK 99516
Current Property owner(s) Joshua Nadell Day phone 317-8788
Mailing address
Real Estate Agent Day phone
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
I]
Individual
F-1
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public !^.Dater System
❑
Pi �blir_. $ewer
❑
Waiver/Variance request for: NONE Distance: ---
Received by:7� Date: 6/111%3P
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ lO� (3 ^ 1 c�lLi ei As "�
Date of Payment (. ( ri I, I ( 7�
Receipt Number 04 IQ (o G
COSA# C) -_c jI X 5 1
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm SPURKLAND ENGINEERING
Phone 279-3916
Address 203 W. 15TH AVE.,STE.202A, ANCHORAGE, AK 99501
Engineer's Printed Name LARS SPURKLAND Date 6/14/13
OF At
o C,
6. DSD SIGGNNgTURE i .
V System #1 Approved for 3 bedroolns % ' ...'.. .
System #2 Approved for bedrooms
Disapproved
Conditional approval for bedrooms, with the following stipuls ii
By: t1 ' Original Certificate Date: 6-17-13
Thenil lty 'f orage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet E i c
If more than 1 septic system is on the lot:
COSA Checklist # _of _
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: LOMA ESTATES BLOCK 1 LOT 1
Well type Private If A, B, or C provide PWSID #
Date completed 2/2/1994 Sanitary seal (YIN) Y
Total depth 74 ft. Cased to 74 ft.
FROM WELL LOG
Date of test 2/2/1994
Static water level 30
Well production 10
ft.
WATER SAMPLE RESULTS:
w
Coliform Neg colonies/100 mL Nitrate 'mg/L
Arsenic �'�� ug1L Date of sample:
517113
B. SEPTICIHOLDING TANK DATA
Tank Type/Material Septic/Steel
Tank size 1250 gal. Number of Compartments 2
Foundation cleanout (YIN) Y
Date of pumping 6/11113
C. ABSORPTION FIELD DATA
Parcel ID: 020-092-29
Well Log (YIN) Y
Wires properly protected (YIN) Y
Casing height (above ground) 18+ in.
AT INSPECTION
6/12/13
29
6.2
ft.
g. p. m.
Collected by: Gayness Engineering
Date installed 10/13/1993
Cleanouts (YIN) Y
Depression over tank (YIN) N High water alarm (YIN) N
Pumper Denali Sewer and Drain
Date installed 10/13/199: Soil rating0.6 Trench
(g.p.d./ft or ftz/bdrm) System type
Length 93 (2`46.5) ft Width 5 ft. Gravel below pipe 3 ft.
Total depth 7'1/7.1 ft. Eff. absorption area 801.7 fiz Monitoring tube y Depression over field n
Date of adequacy test 6/22113 Results (Pass/Fail) Pass For 3 bedrooms
Fluid depth in absorption field before test 29'5129 in. Water added 450 30.5/345
p p gal. New depth in.
Elapsed Time: 1080 min. Final fluid depth 25/30 in. Absorption rate >= 450 9 p d
Any rejuvenation treatment (past 12 mo.) (YIN & type) No If yes, give date _
D. LIFT STATION
Date installed
"Pump on" level at
Datum
Size in gallons
in. "Pump off' level at
E. SEPARATION DISTANCES
WELL ON LOT TO:
Cycles tested _
Septic tank/lift station on lot '100'
Absorption field on lot >100
Public sewer main »5
Sewer /septic service line >25
Animal containment areas >50'
Manhole/Access (Y/N)
in. High water alarm level at in.
Meets alarm & circuit requirements? _
On adjacent lots '1001
On adjacent lots >100,
Public sewer manhole/cleanout >100'
Holding tank >100,
Manurelanimal excrete storage areas >100'
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5 Property line >5
Water main >10 Water service line >10'
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOT TO:
Property line >10 Building foundation >10,
Water Service line >10 Surface water >100
>50' (N.O.) >100,
Curtain drain Wells on adjacent lots
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name
Date
COSA brown sheet -1 0-10-1 2.doc
Absorption field >5
Surface water >100,
Water main >10'
Driveway, parking/vehicle storage >10'
OF A4
49�+t�l
i
.... . ... .. ......
SPU9KLANO,�� j
�1li�FOF 1�I59 t}
Municipality of Anchorage s
Community Development Department°l
Development Services Division
On -Site Water and Wastewater Program
4700 Elmore Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
Nitrate Advisory
Certificate of On -Site Systems Approval # 131257
A Certificate of On -Site Systems Approval inspection and test of potable
water was recently conducted on the well water supply on Block 1, Lot 1 of
Loma Estates subdivision. This inspection revealed a nitrate concentration of
5.02 milligrams per liter (mg/L) was reported for the property's well water
sample. The Environmental Protection Agency (EPA) has established a
maximum contaminant level (MCL) of 10.0 mg/L for public drinking water
systems. While private wells are not subject to this regulation, EPA
standards are based on existing health information and can therefore be used
to gauge the relative quality of water from private wells. Please see the
attached "Nitrate Fact Sheet" for important information regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On -
Site Systems Approval.
Municipality of Anchorage
�.� Development Services Department
Building Safety Division x
On -Site Water and Wastewater Program
4700 Bragaw Street s'
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 020-092-29 COSA # C)5 C_
Expiration Date:�3 �1
1. GENERAL INFORMATION
Complete legal description LOMA ESTATES, LOT 1, BLOCK 1
Location (site address) 16910 BETTITEAN STREET, ANCHORAGE, AK 99516
Current Property owner(s) WILLIAM MORRIS Day phone
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing Address
16910 BETTITEAN STREET, ANCHORAGE, AK 99516
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage.
Community Class Well
Public Water System
3
Day phone
Day phone
TYPE OF WASTEWATER DISPOSAL:
®
Individual On-site
❑
Individual Holding Tank
❑
❑
Community On-site
❑
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm ARCTERRA CONSULTING INC. Phone 868-3792
Address 20441 PTARMIGAN BLVD. EAGLE RIVER AK 99577
Engineer's Printed Name KENNETH M. DUFFUS Date 1/7/2011
Engineer's Comments: This investigation was completed in compliance with ADEC''and MOA regulations. The
assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow
and absorption rates may change due to subsurface conditions that may not be observed from. the surface,
changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the
water usage of the family being served by the system. The operational life of all well and septic systems are
subject to these various and dynamic characteristics and are outside the control of the
evaluator of the well and septic system. Therefore,
ArcTerra can not give any estimate of how long a
system will function satisfactory for current or future 41W
occupants or can ArcTerra guarantee that no unseen:
encroachments, deficiencies or discrepancies exist.
5. DSD SIGNATURE
Approved for bedrooms.
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
♦`. 1.':
J ON-SITE
0 •. G�
�ERAND
WASTEWATER
IVT
Attachments:
COSA Checklist X Arsenic Advisory
Septic System Advisory Maintenance Agreements
Well Flow Advisory Supplemental Engineer's Report
Nitrate Advisory Other
By: �-' "" �Y� Original Certificate Date:_
(Rev. 11/05)
Municipality of Anchorage *At
Development Services-DepartmentBuilding Safety DivisionOn-Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: LOMA ESTATES, LOT 1, BLOCK 1 Parcel ID: 020-092-29
A. WELL DATA
Well type FMAT.E If A, B, or C provide PWStD # Well; Log (Y/N) Y
Date completed ZIV1994 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y
Total depth 74 ft. Cased to 74 ft.
FROM WELL LOG
Date of test 2/2/1994
Static water level 30 ft.
Well production 10 g.p.m.
WATER SAMPLE RESULTS:
Casing height (above ground) 18+ in.
AT INSPECTION
12/22/2010
38 ft.
6.3 g.p.m.
Coliform 0 colonies/100mL Nitrate 4.05 mg/L
Arsenic: ND mg/I Date of sample: 12/27/10 Collected by: ArcTerra
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material fttic/Steel Date installed 10131993 Tank size low gal.
Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N
High water alarm (Y/N) N Date of pumping 1/3/2011 Pumper Denali
C. ABSORPTION FIELD DATA (south/north trench)
Date installed 10131993 Soil rating (g.p.d./fe or fe/bdrm) 0_6 System type Trench
qu.s
Length 93 (2 x 16B) ft. Width 5 -ft. Gravel below pipe 3 ft. Total depth 7.08 7.10 ft. (Measured 12/22/10)
Eff. absorption area 801.7fl? Monitoring tube Y
Date of adequacy test 12/22/2010
Depression over field N
Results (Pass/Fail) Pass For 3 bedrooms
Fluid depth in absorption field before test 16 16 in. Water added 380 500 gal. New depth 20 23 in.
Elapsed Time: 1200 min. Final fluid depth 15 17 in. Absorption rate >= 450+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date -_
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N)
"Pump on" level at in. "Pump off level at in. High water alarm level at in.
Datum Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+
Absorption field on lot 1001+
On adjacent lots 1001+
On adjacent lots 1001+
Public sewer main 751+ Public sewer manhole/cleanout 100'+
Sewer /septic service One 251+ Holding tank 1001+
Animal containment areas 5o'+ Manure/animal excrete storage areas loo'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 51+ Property line 51+
Absorption field 51+
Water main 10'+ Water service line lo'+ Surface water 1o0'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 1o'+ Building foundation 101+ Water main 1o'+
Water Service line 101+ Surface water 100'+ Driveway, parking/vehide storage 10'+
Curtain drain 50'+ (None Known) Wells on adjacent lots 100'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipai records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name KENNETH M. DUFFUS
Date 01/07/2011
COSA Fee $490.00 Waiver Fee $ _
Date of Payment Date of Payment
Receipt Number b�-15a C, Receipt Number
(Rev. 11/05)
Municipality of Anchorage
1 Development Services Department ;4
.� ##!!
— i Building Safety Division l�t
On -Site Water li Wastewater Program • ' . `
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519519.6650
www.muni.org/onsite VT
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. DotO -09a P-9 COSA#(�_R )Lq
1. GENERAL INFORMATION Expiration Date: G n OR
Complete legal description LOMA ESTATES LOT 1 BLOCK 1
Location (site address) 16910 BETTIJEAN STREET • ANCHORAGE AK 99516
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
SHEROL GRUNDMAN Day phone 345-0174
16910 BETTIJEAN STREET + ANCHORAGE AK 99516
_LARRY ROSS w/BUYERS REAL ESTATE
Day phone
Day phone 561-2227
401 EAST FIREWEED LANE SUITE 101 • ANCHORAGE AK 99503
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 3
3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well
Individual On-site
0
Individual Water Storage
❑
Individual Holding tank
❑
Community Class Well
❑
Community On-site
❑
Public Water System
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the
information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Address 3701 E. TUDOR ROAD. SURE 101 " ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, GEG, VD. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines B Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily Identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party Is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE
Approved for 3 bedrooms.
Phone 337-6179
Date 3'3/08
Disapproved.
Conditional approval for bedrooms, with the fllowing stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Reort
Other
�.. .........•e
A. L;;rness,
T3
79 3 v8 «4N
Prof ssslo'Noo
OO�0000
ott jYtOFAV, 0.
J :• ONSITE c
WATER AND
WASTEWATER .
PROGRAM '
per•. •
)1
By: Original Certificate Date:
(Rw. 11005)
Municipality of Anchorage
(� Development Services Department
\ Building Safety Division
On -Site Water 8 Wastewater Program 1 >
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: LOMA ESTATES LOT 1 BLOCK 1 Parcel ID: ,20-09',.�?Cj
A. WELL DATA
Well type PRIVATE If A. B, or C provide PWSID# N/A
Date completed 2/2/1994 Sanitary deal (Y/N) YES
Total depth 74 ft. Cased to 74 ft.
FROM WELL LOG
Date of test 2/2/1994
Static water level 30 g
Well Log (Y/N) YES
Wires properly protected (Y/N) YES
Casing height (above ground) 18'+ In.
AT INSPECTION
2/19/2008
36 ft
Well production 10 g,p,m. 7.20
g.p.m.
WATER SAMPLE RESULTS:
Coliform (7 colonies/100 mi. Nitrate .57mg./L. Other bacteria colonies/100 mi.
Arsenic: "0 ug./L. Date of sample: 2/19/2008 Collected by: GEG Ltd.
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material SEPTIC/STEEL Date installed 10/13/1993
Tank size 1000 gal, Number of Compartments E Cleanouts (Y/N) YES
Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A
Date of pumping 2/19/2008 Pumper AROUND THE CLOCK PUMPING
C. ABSORPTION FIELD DATA BELOW EXISTING GRADE "SOUTH TRENCH /NORTH TRENCH
Date installed 10/13/1993 Soil rating (g.p.d./Wo /bd 0_6
System type 5—WIDES
Length 93 `(2 ® 46.5) ft, Width 5 ft. Gravel below pipe 3 ft,
7.08/
Total depth ft. Eff. absorption area801.7 ft' Monitoring tube YES Depression over field NO
Date of adequacy test "2/19/2008 ! - Results (Pass/Fail) PASS For E bedrooms
Fluid depth in absorption field before test 17/12 in. Water added 720/9 10 gal, New depth 30/26 in.
,
Elapsed Time: 120 min. Final fluid depth 27/24
p _m. Absorption rate >= 450+ g.p.d,
Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date —
D. LIFT STATION
Date installed
"Pump on" level at in.
Size in gallons
"Pump off"
Manhole/Access
water alarm level at In.
n rCvcles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot
100'+ On adjacent lots 100'+
;Absorption field on lot
100'+ On adjacent lots 100'+
Public sewer main
N/A Public sewer manhole/cleanout N/A
Sewer /septic service line 25'+ Holding tank N/A
Animal containment areas
50'+ Manurelanimal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
5'+ Property line_____L+— Absorption field 5'+
Building foundation P rtY
Water main
N/A Water service line 10'+ Surface water 100'+
Wells on adjacent tots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line
10'+
Building foundation
9
10'+
Water main N/A
Water service line
10'+
Surface water
100'+
Driveway. parking/vehicle storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots 100'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through rield inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. GARNESS
��_�M
COSA Fee S / U • w
Date of Payment
Receipt Number % 5 5 9 5
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
G�
•� / a evbeLOW 16.16' � I
J �
1
I I
I
p�' I
L^ 1 I
� 1
1
J• i I i
I I
JJ 6M1 I
-------------
AP..S}1. `• .... r I
•�, C9Zl1 '.... ,�. •'•1 I
in
y\ I
7 •f 1
1
I
1
• \ I � I
/ 1 n
I
A
I 6
�i
l I O
/ • i 1 2
w 1
I� I
1
' 1 I
o
IS
I i" 1
I
I I
1 �
I ,
1
I �
I ,
N ■p 6S' 16• W 156.11 �•.�• � �
fLnwib{ LLLLV1�t�4O•IATRGIpiLNLt 0�14NFLt�yMdNYLLVM►M WV
•1MCLWF)d{F.LfLR\ MN VIED {M gYDjL.pRTN.M
TL'NY
WiLlr/1\d11FCM0 b1•fll T,w 1MN bCw., W M RDD1'fDMT, ME 11D'f 6Pw1.54d
a lC4T[ ti•VCiND(\S�w W lOG1ED M110muTEly NO ME •DT TOl VEFD M DETt.L••( Ma6[m ••e�
1L0,.[t1.LTfi tll
NIiD \T ••pb,1MC MAWLM
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: 3
J
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on 7thea this inspection.
S & S ENGINEERING
Name of FirmEauPhone
Aririrccc va
Eagle River, Alaska 94 77 -
Date
�s C,a
bedrooms.
u
bedrooms, with the following stipulations:
Date 6,; — �¢
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: L( 8? Parcel I.D. On�OO�o2��
A. Well Data r %
Well type RZ\UF,?E If A, B, or C, attach ADEC letter. ADEC water system number
Log present [�/N) YDS Date completed oZa 7LI Driller . LJ
�3q ' Casing height l8"
Total depth _�4 ,/ Cased to
s Wires properly protected (Y/N)
Sanitary seal 6/N) Y;
FROM WELL LOG AT INSPECTION 3
Date of test a -aa-9 4 Z
Static water level rn o z
�0 g.p.m. `
D .<
Well flow g A o
Pump levels C m Z
11`n p y O
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot 1 1 U ; On adjacent lots �� o
l �0 ; On adjacent lots I
Absorption field on lot ,�
Public sewer main OJ/14 Public sewer manhole/cleanout AJ&
Sewer service line
`-F Petroleum tank &VE wN
WATER SAMPLE RESULTS:
11 w` �
Coliform 't � h � � Other bacteria
Collected by:
EA
Date of sample: S �NCr�NfLING
B. SEPTIC/HOLDING TANK DATA
Date installed U 1131` 3 Tank size kn->0 &Pc Compartments
Cleanouts '/ ) Foundation cleanout ON) -Depression (Y/O Ov` 0
High water alarm (Y/61 Alarm tested (Y/N)
Date of pumping �— U ` Pumper
SEPARATION DISTANCES FROM SEPTIC/ TANK TO:
Well(s) on lot On adjacent lots I Oc5
(.►- Foundation o20
TO property line ISO Absorption field l0 � Water main/service line
Surface water/drainage I f
CONTINUED ON BACK PAGE
72-026 (3/93)' Front
C. LIFT STATIO n '/
Date installed
Size in gallons
Vent(Y/N)
High water alarm level
"Pump on" level at
Meets MOA electrical codes (Y/N)
SEPARATION DISTANCE
Well on
D. ABSORPTION FIELD DATA
LIFT STATION TO:
On adjacent lots
Manufacturer
Manhole/Access
"Pump off" Level at
Surface water
Date installed Soil rating (GPD/Ft) 6PPIS System type S-14tc l -()lit) w OE -me,2
LengthId y3' 93 idth S Gravel thickness 3 Total depth r
T07K
Total absorption area Pn( St- Cleanout present O/N) eS Depression over field (Y�) J
Date of adequacy test 1,14 –/)�w Sys, Results (pass/fail) LZ for –3, Bedrooms
Water level in absorption field before test ��� – a Ucw "Q54„ After test '��
Peroxide treatment (past 12 months) (Y/6) N o If yes, give date /`,/A_
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot 1,.�0 _r On adjacent lots z o U f Property line �U f
To building foundation y.c� f To existing or abandoned system on lot
On adjacent lots C -O f Cutbank LL14 Water main/service line
i
Surface water 6�y) Driveway, parking/vehicle storage area 5 y
Curtain drain VUo&)F (_nlowry
E. ENGINEER'S CERTIFICATION
/ certify that/ have checked, verified, or
Signature
170-34 Ea91e Liver
Engineer's Namga
Date —
MOA and HAA guidelines in effect nri, the
HAA Fee $. ' Waiver Fee $
Date of Payment / ./ (� Date of Payment
Receipt Number Receipt Number
atP o this inspection.