HomeMy WebLinkAboutMCCARREY Lots 1-6 Plat# 92-88 S-9236
Department of Economic DeveloPment
and Planning
May 5, 1992
Page Two
S-9233:
S-9234:
S-9235:
S-9236:
S-9237:
S-9238:
S-9239:
Plat Checklist and Addendum Checklist No objection.
Lots 16A thru 16F Block 10 Green Acres Subdivision No objection.
Lot 6A Block 5 Greenland Subdivision
DHHS is able to support only a portion of this
platting request. Under provisions of AMC 15.65.180.A,
Lot 15 may increase in size. Lot 6 may also be
increased since it has a dwelling and a conforming
on-site disposal system (AMC 15.65.180.D).. However,
Lot 7 is not 40,000 square feet nor does it contain
an existing system. Therefore we are unable to
support any change to this lot. We will support the
resubdivision of Lots 15 and 6.
Lots 1 thru 6 Mc Carrey SubdiVision
The following items are required for this plat:
1. The applicant must designate the appropriate
reserve disposal area on Lots 1 and 2.
2. Provide actual location of testhole on Lot 2.
3. Submi% information on missing testholes 7 thru 9.
4. Provide water monitoring through the seasonal
high water period (approximately the middle of May)°
5. Prior to final plat, upgrade the existing sewer
system, serving the dwelling on Lot 2.
Lots 1 thru 6 & Tract C2 Foxhall Subdivision No objection.
East 43' Lot 6 La Foret Subdivision
DHHS has complete records for this property. No
objection.
Cross Pointe Subdivision No objection.
SO/ljm
MUNICIPALITY OF ANCHORAGE
ECONOMIC DEVELOPMENT AND PLANNING
P.O, Box 196650
Anchorage, Alaska 99519-6650
PRELIMINARY PLAT APPLICATION
OFFICE U~
REC'D BY:
VERIFY OWN:
Please fill in the information requested below. Print one letter or number per block. Do not write in the shaded bi cks.
1. Vacation Code 2. Tax Identification No.
3. NEW abbreviated legal description (T12N R2W SEC 2 LOT 45 OR SHORT SUB BLK 3 LOTS 34).
EXISTING abbreviated legal description (T12N R2W SEC 2 LOT 45 OR SHORT SUB BLK 3 LOTS 34) full legal on back page.
Petitioner's Name (Last - First) 6. Petitioner's Representative
J,4J ,,J EJcbJoJ JllJJJJJJJJJ
Address ~-- ~' ! ~
City ~ ~ ¢'~ ~'1 State
Phone~ ~'~/~ Zip
7. Petition Area 8. Proposed 9. Existing
Acreage Number Number
Lots Lots
10. Grid Number 11. Zone
12. FeeS 13. Community Council
B. I hereby certify that (I am) (I have been authorized to act for) the owner of the property described above and that I desire to subdivide it in
conformance with Chapter 21 of the Anchorage Mu nicipal Code of Ordinances. I understand that payment of the basic subdivision fee
is nonrefundable and is to cover the costs associated with processing this application, that it does not assure approval of the
subdivision. I also understand that additional fees may be assessed if the Municipality's costs to process this application exceed the
basic fee. t further understand that assigned hearing dates are tentative and may have to be postponed by Planning Staff, Platting
Oete:°ard' ~aTir 'zC~7;~the Assemb" due~7' j~_~~/.~
Signature
*Agents must provide written proof or authorization,
20-003 (Rev 6/89)MOA-24
Please check or fill in the following:
1. Comprehensive Plan -- Land Use Classification
Residential
Commercial
Parks/Open Space
Transportation Related
2. Comprehensive Plan -- Land Use Intensity
Special Study
3. Environmental Factors (if any):
a. Wetland
1. Developable
2. Conservation
3. Preservation
Marginal Land
Corn merciai/Industrial
Public Lands/Institutions
Dwelling Units per Acre
Alpine/Slope Affected
b. Avalanche
c. Floodplain
d. Seismic Zone (Harding/Lawson)
Please indicate below if any of these events have occurred in the last three years on the property.
Rezoning Case Number
Subdivision Case Number
Conditional Use Case Number
Zoning Variance Case Number
Enforcement Action For
Building/Land Use Permit For
Army Corp of Engineers Permit
Legal description for advertising.
Alpine/Slope Affected
Industrial
Special Study
Checklist
30 Copies of Plat
Reduced Copy of Plat (8~/2 x 11)
Certificate to Plat
Fee
Topo Map 3 Copies
Soils Report 4 Copies
Aerial Photo
Housing Stock Map
Zoning Map
Water:
Sewer:
Private Wells
t,.,'~'Private Septic
Waiver
Community Well
Community Sys.
Public Utility
Public Utility
20-003 Back (Rev. 6/89)MOA-24
April 23, 1992
Mr. Michael Anderson
2515 A Street
Anchorage, Alaska 99503
RECEJVED
APR ~ ? 19~
Municipality of Anchorage
Dept. Health & Human Services
Subject:
Evaluation of the potential and expected drainage patterns of the proposed
Lots 1 through 6, McCarrey Subdivision, Anchorage.
Dear Mr. Anderson:
You have requested that I evaluate the potential and expected drainage patterns of the proposed
McCarrey Subdivision. The approximately 10 acre presently unplatted parcel is located on the
eastern side of Golden View Drive approximately 1300 feet to the north of the Rabbit Creek
Road and Golden View Drive intersection. The site is rectangular in shape with approximately
330 feet common with and adjacent to Golden View Drive and projecting towards the east
approximately 1320 feet. The eastern portion of the parcel is adjacent to Pickett Street. This
information is visually illustrated with the enclosed topographic map you provided to me.
As required by the Municipality of Anchorage (MOA) a topographic map of the proposed area
shall be submitted. Enclosed with this letter is a copy of the topographic map you have provided.
The map is a photocopy of the MOA topographic map Sec. 35, T12N, R3W, S.M., Scale 1"=285',
1979. The topography shown on the MOA map is a good representation of the relief of the subject
parcel. On the enclosed drawing the approximate boundaries of the site and existing streets have
been placed on the drawing. No existing or proposed drainage structures are located within the
surrounding area of the parcel. No surface water or drainage areas were identified on the parcel.
As can be detemfined from the enclosed topographic map the western 2/3 of the parcel slopes
towards the west and the eastern 1/3 slopes towards the south. All drainage from the site is
suspected to be transported to the small drainage approximately 900 feet to the south of the site.
This eventually connects with Rabbit Creek. Water transport is either through a shallow
groundwater aquifer or by surface sheet flow. Several test pits were excavated throughout the site
to a depth of 15 feet. Groundwater monitoring tubes were installed in these excavations and no
groundwater was detected to the 15 foot depth at any of the test pit locations. Additionally, no
surface drainage channels were observed in the area of the parcel and surrounding parcels. The
roadways adjacent to the parcel have been constructed not having drainage ditches. No evidence
Mr. Michael Anderson
April 23, 1992
Page 2
of surface drainage erosion was observed along any of the roadways common with the parcel.
Except for the existing honse located on proposed Lot 1 the parcel is undeveloped. Site vegetation
consists mainly of large birch and spruce trees. The parcel is proposed to be used for residential
development and little change is anticipated in the topography of the site after subdivision.
I appreciate the opportunity to provide the above information to you. If you have questions
concerning the infornnation outlined in this letter, please call me.
Sincerely,
Michael B. Brodie, P.E.
,81~'SOI I
~90,§0o00 ]
,,,
~ .00,~;0o00 N
~ ,9~'~96£
April 24, 1992
Department of Health and Human Services ~ -- ~'~. ~,~ ~
Anchorage, Alaska
Re: Evaluation of the soils on the proposed McCarray Subdivision, Anchorage, Ak.
DearDHHS,
After logging and testing of the soils and measurement of the water levels in the fore mentioned
property the following conclusions are:
1) The water table is lower than 16 feet on all six lots.
2) All the lots will support a four bedroom wastewater system.
3)
The Subdivision will not be impacted by the existing surrounding property wastewater
disposal systems. See attached map for location of all wells surrounding the subject
parcel.
A total number of nine holes were excavated on the property, with three holes (#5,7,9) being just
for water level monitoring (see map). The soils on test hole #5 and #7 had a 3 to 6 foot layer of
good gravel. Test hole #9 was sandy-gravely-silts for the first 9 feet then silts. See enclosed soil
logs for soil descriptions at each test pit location on subject pamel.
Below is a summation of the existing systems which border the property. This provides you the
overall soil types which match our investigation results. ].
LOT WELL DEPTH FLOW RATE BEDROOMS PERK RATE GROUND WATER
(fi) (Gal/Min) ..(im/mht)~- & DEPTH
1 90 2 4 13 NONE
2 77 6 3 13 YES @ 8.6'
3 96 4 3 28 NONE
4 63 16 4 12.5 NONE
5 77 10 3 4.1 NON E
6 80 1.5 3
7 65 2 3 19
8 120 5 3 23 NONE
9 107 3 60 NON E
10 100 2 3
Michael Brodie, P.E.
CIR.
I0' TELE.o ELEC.
165~
165'
165 '
145'
ST.
P. / '..'. '~
Municipality o~ Anchor, ge I~ ......... ~.~~ ......
DEPARTMENT OF HEALTH & HUMAN SERVICES ,. : :
J
825 "L" Street, Anchorage, Alaska 99502-0650 j
SOILS LOG -- PERCOLATION TEST
P~oPoS~D Lom 2 ~CA~eey JoB~. Township, Range. Section:
LEGAL DESCRIPTION:
SLOPE SITE PLAN
3
7
8
10 ~ GROUNDWATER
ENCOUNTERED?
S~
11 L;
IF YES, AT WHAT K~ /~
12 DEPTH?
Oepth to Water ,Alter
13- Monitoring? NO ~.¥V/. Date:
Gross .,~ Net /~4 ~'~ Depth to Net
Reading Date Time ~'MIN~ ~.-,-/Time ~ Water Drop
14-
16
17
18
19
20
PERCOLATION RATE__~ (mmutes~lnch) PERC HOLE DIAMETER 'TC~P -- IZ'
.~o"'r'r~,~*.t = ~ '
TEST RUN BETWEEN g'~ FTAND ~/'~ FT
COMMENTS ~ ~t5 ~ /&~ I~ US~ ~ ~ 15p~ ~ ~
PERFORMED BY: /41/~11~ ~JDg~_ 50/~J I /~,,~'/~,,6,gc. ]~eODq'~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATEAND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DAT~ A~'~--''~YI /q?
72~ (Rev. 4/~)
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19-
20-
Township, Range, Section:
SLOPE
SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
S
IF YES, AT WHAT /~. L
DEPTH? Nit. pO
E
Depth to Water ~A[ter
Monitorino? ~Jo ~.~. Date: ~'
Reading Date Gross Net Depth to Net
Time Time Water Drop
PERCOLATION RATE ~ (m~nutes/mcl~) PERC HOLE DIAMETER ToP = IZ/t
TEST RUN BETWEEN ~' FT AND '7 FT
PERFORMED BY: MI ~ ~O ~ 5~ I ~t~ ~EO~,~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~-/~el/,_. ~?! 1~ ~..
72-008 (Rev. 4/85)
PERFORMED FOR:
LEGAL DESCRIPTION:
4
5
6
7
8
9
10
13
t4
15
16
17
18
19
20
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Ancl~orage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
LoT ,~.~ /~c¢,/¥&£6y' ~'oSD. Township, Range, Section:
SLOPE
WAS GROUND WATER
ENCOUNTERED?
iF YES, AT WHAT
DEPTH?
SITE PLAN
Oepth to Water After
Monitm'ing? /'.)~, ~.V~. Dale:
Gross Net / % Depth to Net
Reading Date Time
Time ~,.M I") Water Drop
~/-18-I~ o o
~'O la I, z ~' '
(m~nutesnncb) PERC HOLE DIAMETER
-7 FT AND ~ FT
PERCOLATION RATE __
TEST RUN BETWEEN
COMMENTS
~_.~.
PERFORMED BY: /¥(( ¢~.. ~O&~-~.o4 I /I/~, ~./~-t~-z.- t~oO I~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: (~,L.. ,~ ~7/! /~' ~
72-008 (Rev. 4/85)
PERFORMED FOR:
LEGAL DESCRIPTION:
1
2
3
4
5
6
7
8
9
10
11
12
13,
14
15
16
17
18
19
20-
COMMENTS
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
ZO'/' ¢., /~tO,4-E£¢¢ ~'0,6/:). Townsmp. Range. Section:
SITE PLAN
SLOPE
WAS GROUND WATER
ENCOUNTERED?
S
IFYES, ATWHAT ~/,~, ~
DEPTH? p
E
'5'Oep~ to Water ~er
Moni~ring? /~o ~, ~V/. Oa~ ~-Z~-~L
Gro. Ne, De.t, to Ne,
Reading Date Time Time Water Drop
(o (o I, Z ~
PERCOLATION RATE ~ (m~nutes,'~nctt) PERC HOLE DIAMETER
TEST RUN BETWEEN ~ FT AND '7 FT
PERFORMED BY: /~,1.(.~. A-~Pr-..~Sc~ , /~'~J'~,~.~- ~/~-OP,(_ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
PERFORMED FOR:
LEGAL DESCRIPTION:
~)EPTH
FEET)
1
2
4
7
8
12
13-
14-
15-
16-
17
1@
20
COMMENTS
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
Lo-r ¢', Township, Range, Section:
SLOPE
WAS GROUND WATER
ENCOUNTERED?
S
IF YES, AT WHAT /~,
DEPTH? I~J
E
Depth Io Waler After
Monitoring? Mo ~// Date: tJ-g'-/-qZ-
SITE PLAN
Gross/ '~ Net (N~ ~ Depthto Net /
Reading Date Time (A4~/I Time ~ Water Drop {,tl~]
q-18 - ff~ 0 o
lo ~o ~.o
PERCOLATION RATE ~ {m,nutesanch) PERC HOLE DIAMETER
TEST RUN BETWEEN 3 FT AND ~/ FT
PERFORMED BY: /~'~' ~,~ ~r..~-- :~,c~ i /~/~1/_/~.~ ~l~::)O ,{_ CERTIFY THAT THIS TEST WAS PERFORMED I"
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~.
72-008 (Rev. 4/85)
PERFORMED FOR:
LEGAL OESCRIPTION:
2
3
4
~ .
7
8
10
14
17
18
20-
Municipality et Anchorage ~ ...... . ......
DEPARTMENT OF HEALTH & HUMAN SERVICES ~,?~. /Vdcha~J [3. Brodie
825 "L" Street, Anchorage, Alaska 99502-0650 ~'C:."-. CE. 7442
SOILS LOG -- PERCOLATION TEST ~ ~C'- .....
~ ~ ~'; ,., 'r - .,' '.'L ~.~'~
d, M4 0~ ~o*0. Towns"ip. Range. Section:
SLOPE SITE PLAN
i/ce'
I<
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Depth to Water A.II~r
Monitoring? No ~. Tg/, riate:
Gross ~} Net / N Depthto Net ~)
Reading Date Time ~' Time k/qt~] Water Drop
q-/~-'~ o o
to lo 3.5
Zo to ~.1
d/ ~o ~o & S
qo ID ~,~
PERCOLATION RATE g~' (minutes/inch) PERC HOLE DIAMETER 'TOP
6"
TEST RUN BETWEEN ~' ~' FT AND L/.~- FT
COMMENTS
PERFORMED BY: /~t~C~' ~,'J~,~g. 5oM I /~'~'~ ~OC~, ~. CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATEi DATE: A~PE-I b ~! I~ Z-
72-008 (Rev. 4/85)
4¸,
August 20, 1992
Department of Health and Human Services
Anchorage, Alaska
RECEIVED
AUG 2 0 1992
...... , oervlces
Re: Evaluation of the soils of the proposed McCarrey Subdivision, Anchorage,
Ak.
Dear Susan,
This is the information that was needed for the McCa'rrey subdivision to show
that the soils on lots 1 & 2 will support an on-site septic system. The original
soils investigation on all the lots was performed in April with test holes 1,2,3,4,6
& 8 being perk and water monitoring sites, but test holes 5,7, & 9 being strictly a
water monitoring station. You asked me for a showing of the reserve area for
lots 1 & 2 near the water monitoring station #7 (see attached plat of subdivision),
therefore a perk test was run at this location to show that the soils are
acceptable ( see attached). The water monitoring has been checked weekly
from the original soils investigation showing the water table to be below 15.5 ft
(no water was found). The reserve area of 12,000 square ft is shown on the plat
which is acceptable for the soils found. If you have any more questions please
call.
Sincerely
Michael Anderson
B.L.M. MONUMENT FOUND
REBAR FOUND
M OF A MONUMENT FOUND 2.
I I/2' AL. CAP ON 5/8" X 30" REBAR SET
AL. MONUME.T SET F ! V ED'
AUG 2 0 1992
. ~ ,'~,','o~'age
/2' BO · -~.., ~. ;~.;,a;'~ Services
252.41 REC.
N 89e~16'29" E 251.57'
252~.5 I
252,47 REC.
N 89°53,'02' E 2"14.16'
--RTON AV~.
1.880
S 89e19'02" W ~
EXISTING
HOUSE
.10' DRAINAGE EASEMENT
:IBOo
CERTIFICATE
I' CURVE DATA
· '~. R T L
~ (~) 59'~51'P'2" 50.00 28.78 52.23
(~) 59cOS'lO" 50.00 28.35 51.58
~ 3~28'13" 50.00 16.94 32.67
~ ~6*~0~9' 50.00 16.57 52.00
~ 90'0~4" 20.00 20.03 31.44
Honte R. ~onitzke . , professional land surveyor do h~eby cai'lily
:t t#e plat of f~cCarrey Subdivision /~ · true and correct r~re~enta~ion
~and~ actuaUy ~veyed and t~at the d/~tance~ and bea~n~
~rectly and that all pennant exterior contro~ ~n~nt$, all other
n~ntz, and lot corner$ have been set and ztaffed, or If ftnmJ c~letloo
~d/vlsiofl a~e~nt. ~ot co~fle~$ to be $et by
,?~nt$ to be ~et
LA T APP~VA~
at app~ovaJ by t~e ~fc/pa~ Platting Aut~ity
i~ day of · 1~.
NOTES:
I. LOT 6 TOTAL AREA INCLUDING 1/2 OF ABUTING
RIGHT OF WAY IS 1.511 AC.
ALL LOTS WILL HAVE ITS OWN WELL.
LAND LOCKED PARCELS HAVE ACCESS EASEMENTS RECORDING
IN ANCHORAGE RECORDING DISTRICT BOOK 253. PAGE 55-55
AND BOOK Ill. PAGE 51-52.
THIS PLAT IS DEDICATING A PRIVATE ACCESS EASEMENT Al.ON
THE EXISTING SARABELLA LANE ON LOTS 2 AND 3 FOR THE
BENEFIT OF LOT 2 (M¢CARREY SUBDIVISION) AND UNDER PROP
CONTIGUOUS TO AND SOUTH OF LOTS ~' AND :5. M¢CARREY SUE
3
S 89'56'51" E REC.
50"t.
252dl7 REC. 504.
UTILITY EASEMENT
'UBO,
r5 MEA.
~1 REC
N 89·51'35' E $5T. 15'
89~53'02' E
8.$5' LOT 4
1.577 AC,
N 89'55'5'~' E
235.61'
L,q' IL ITY ESMT.
LOT3
I.~117 AC.
135.28~.---
252."17 REC. '~__.
N8g~51'35'E
LOT
I.:578
S 89·53'53' W
S89eSI'28'W 2~16.62' R-50.O0' o
$0' PUBLIC USE S
DRAINAGE 8~
UTILITY ESMT.
ESTATES
ESTATES
ACCEPTANCE OF DEl)ICA T/ON '
2 1/2' AL. MON.
~he tluniclpalfty of ~nco~a~e hereby accepts for public uses an~l
fop puOl /c purposed the real p~ope~y dedicated on tMs plat
including, but flat ;fmited to the e~nt$, Pl~t~o~y, al~e~,
roa~ys, thoroughf~e~ ~d parks sh~ here~.
Oared at/~ch°~age, Ala~lta this day of
I~unicipa~ Clerl~
TAX CENT/F,
&Il real propert~
~ncho~age on the
APPROVALS
Platttng Officer,i
Hunicloal 5u~vey~
Municipality of Anchorage
so, s
PERFORMED FOR:~O~ ~ ~~ DATE PERFORMED:
LEGAL DESCRIPTION: &~ I ~E~% ~o~Township, Range, Section:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20-
RECEIVED
AUG 2 0 1997-
Mumc~pal :y u~ ~,;~6~§~ND WATER
Oept, Health & Hum~
SLOPE SITE PLAN
S
L
IF YES, AT WHAT ~'/(~ O
DEPTH? p
E
Depth to Water Alter
Monitoring? ~ Date: ~
Gross Net Depth to Net
Reading Date Time Time Water Drop
~o ~o
PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN ~ FT AND lc) FT
PERFORMED BY: ~f, LI(.E &c-J~,¢,~¢,--~' I ~-~"~: ~b~.~'~l~,~O~OzCf~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES iN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
September 21, 1992
USKH
2515 A Street
Anchorage, Alaska
99503
Attention: Mike Anderson
CHUGACH ELECTRIC
ASSOCIATION, INC.
N%unlc~P . . .,..~n Services
Dept. Healtf~ a mu,,,~n
Subject:
Encroachment Agreement
Lot 2, McCarrey Subdivision
Grid 3038
Dear Mr. Anderson:
Enclosed is the Encroachment Agreement you requested on Lot 2,
McCarrey Subdivision.
If your clients are agreeable with the conditions, please have
them sign the document and return it in the enclosed envelope.
The original document must be kept on file in this office.
If you have any questions, please contact me at 762-4735.
Sincerely,
Susan Truskett
Right-of-Way Agent
ST/kjt
LETTERS/33
Enclosure
560t Minnesota Drive · RO, Box '196300 · Anchorage, Alaska 995'19-0300
Phone 907-563-7494 · FAX 907-562-0027
ENCROACHMENT AGREEMENT SEP ~ 3 ~9~,2
, ~ .... ' 0,~( -
Oep~ He:- ' ' ge
. alth & Human Services
THIS AGRE~ENT, made and entered into this 21st day of
September, 1992, by and between CHUGACH ELECTRIC ASSOCIATION,
INC., an Alaska non-profit electric cooperative membership
corporation of Anchorage, Alaska, hereinafter called "First
Party" and Sally Monserud Trust of Anchorage, Alaska, hereinafter
called "Second Party", WITNESSETH T~T:
WHEREAS, First Party occupies an easement on Lot Two
(2), McCarrey Subdivision, Anchorage Recording District, Alaska;
and
WHEREAS, Second Party has proposed to construct a leach
field into the foregoing easement.
NOW, THEREFORE, for and in consideration of their
mutual agreements and other good and valuable consideration, the
receipt of which is hereby acknowledged, First Party, for itself,
its successors and assigns, waives its objections to Second
Party's encroachment on the said easement for the purpose
mentioned, subject to the following conditions:
1. Second Party will hold First Party harmless from
liability for any injury or damage to any person or property
which may result from such encroachment.
2. The said encroachment will be without prejudice to
First Party's full enjoyment of any and all rights it may have in
and to such easement.
3. Any facilities or property of First Party which
are damaged or destroyed as a result of such encroachment will be
repaired or replaced at no cost to First Party.
4. Second Party will comply with all applicable
safety codes and regulations.
5. Any expenses which First Party may incur in the
relocation or modification of its facilities to accommodate the
said ~~i; by
encroachment will be pa Second Party.
6. Second ~~il~ve two four-inch PVC conduits
installed within the~s~/ o~ west side of said lot.
By its executi{~n of this Agreement, Second Party
agrees, for itself, its successors, and assigns, that its
encroachment upon the named easement as hereinabove mentioned
will be subject to the foregoing conditions.
IN WITNESS WHEREOF, the parties have caused this
Agreement to be executed by their duly authorized representatives
and agents as of the day and year first above mentioned.
CHUGACH ELECTRIC
ASSOCIATION, INC
('~h~ t.. Gene~l Ma.n~r
. '7"~; DaSd L. H~g~ers
,~-_r r.,9 7--£ ,,,e., -~.,...--
SAI.T.Y MONSERUD ~,
'(Second party)
Mike Walton
National Bank of Alaska,
T~dstee for Sally Monserud Trust
ZZ
0
E '660.29j PI~P
84-29&
REC.(2)
5286.25 MEA. VIEj'~/ ~
NOO~O5'OO'W 330.~8' PROP.
REC. J
224,96'
149.92'
991.49' PROP.
CEA ESMT.