Loading...
HomeMy WebLinkAboutHIGHLAND BLK 1 LT 10LIO I1 1 NAME MUNICIPALITY O~i_~')L~iI~yAS~ ANC, .AGE DEPARTMENT OF HEALTH &. EN.V. IRE~E~)~:'t;i~OtYECTION ENVIRONMENTAL E N G I~ii~l~li~t~:i.~ I V I si ONCTION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/d'(~/~LZOLi~ (~.~i~ECTION REPORT 0M N I NoA¥ff MAILING ADDRESS LEGAL DESCRIPTION LOCATION LoT 10 ~ B~~ z H/Gfl~D OPF ff[~TT ~'war ~E,~ Sff[TCr/) 0N ~ ~ DISTANCE TO: Absorption area h ~ Manufacturer Liq. capacity i~ ,. Insid~ length - I O O¢ [ ,. HOMEMADE: ~ v DISTANCE TO: ~Well Dwelling O ~ ~ Manufacturer Q Well Foundation ~ ~ISTANC[ TO: ~ ~ ~o. of lines ~en~th of each line Total ~on~th of lines i:~~= ~ ~' _Z~ ~h Top of tile to finish grade ~1 U Material beneath tile Length Width DISTANCE TO: Well Class Depth DISTANCE TO: Depth Crib depth Building foundation Driller Building foundation Sewer line OTHER S u~l)~ vJ_~jeN ~4M6£LL tDwellin.(i inches IMaterial ~T'e~Tfot ~ipe __ h'rench w}dth NO. OF BEDROOMS PERMIT NO. No. of comE-tments Liquid depth PERMIT NO. Liquid capacity in gallons PERMIT NO, r~ NEW [] UPGRADE Distance between lines Total effective absorption area PERMIT NO. PIPE MATERIALS To SOIL TEST RATING line MI'F NO. ?'ption area(s) INSTALLER REMARKS ),.0 Al G t ~ APPROVED DATE LEGAL 72-013 (Rev. 3/78) PERMIT NO~ DEPRRTMENT OF HERL. TH FIND EN',,,'IRONMENTRL PROTEC'TION 825 '"L.'" STREET., RNCHORFIGE, FIl<. 9950i 264-4720 K_-.~ ~4 .... ."~ ~ -T' [3': ~ E ~..! ~ ~." F" E ~4~- P,-I Z: 'T ( 8000?6 ) FlF'P L. I CFlNT LOCRT I ON LEGAl_ OMNI NORTH E:X ±kq-5?Z.: RNCH 995i:1. ~.:;EWR R [:, LT. : &O BLK. ~ HtGHLFIND S/C:,:.' LO'F SIZE 344-2560 9450 SQURRE FEET T'-r'PE: OF:' SOIL RBSORPTION S~'STEM IS: TRENCH I'"IW,:.~IMUM NUMBER OF BE:DROOP'IS SOIL RR'rING (SQ FT,."BR)= :1.00 'THE REQUIRED SIZE OF' THE SOIL RBSORPTION SYSTEM IS: THE LENG'rH DIHENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIEL[:,. THE DEPTH OF R TRENCH OR PIT IS THE E:,ISTRNCE BETWEEN THE SURFRC:E OF THE GROUND RND THE BOTTOM OF THE ENCRVRTION ,.'.IN FEET). THERE IS NO SET' WIDTH FOR TRENCHES. 'FI4E GRFIVEL. [:,EPTH IS THE MINIhlUM DEPTH OF GRWv'EL DE'THEEN THE OIJTFFIL. I_ PIF'E RND THE: BOTTOM OF THE EXCRVRTION (IN FEET). F'ERMIT RPPLICF~NT HRS THE RESPONSIBILIT~r' TO INF'ORM THIS DEPRR'TblENT DLIRING THE INSTFIL. LFITION INSPECTIONS OF RN"r' WEI_,L.S RDJRCENT TO THIS PROPERT"r' BP'iD THE NUMBER OF RESIDENCES THRT THE WELL WILL SER'¢E. E:RCKFILLING OF RN'¢ S~r'STEM WITHOUT FINRL INSPECTION RND RPPRO',,"RL B'Y THIS DEPRRTblENT WIt_L BE SUBJECT TO PROSECUTION. MINIMUH DISTFINCE BETWEEN R WEI_L RND RN'¢ ON-SITE SEI.4RGE DISPOSRL S'T'STEM IS t00 FEET FOR'. Fl PRIVFITE WELl_ OR i50 TO 200 FEET FROM FI PUBLIC 1.4ELL [:,EPEN[:,ING IJPON THE T'¢F'E OF PUE:LIC WELL. HINIMUH [:,I~,TFINCE FROM R PRIVF4TE: WELL TO FI F'RI',,,'FITE SEP.IER LINE IS ;25 FEET FIN[.', TO Fl COMHUNIT'Y SEWER I...INE IS 75 FEET. OTHER REQUIREMENTS HFI~r' FIPPL'¢. SF'ECIFICFITIONS FIN[:, CONSTRUCTION DIRGRFIMS F:IRE I::IVFII. LFIBLE TO INSURE. PROPER INSTFll...LFITION. I CERTIF'r' THRT :L: I FlM FRHILIFIR P.IITH 'THE REQUIREMENTS FOR ON-SITE SEWERS FIND 14ELL. S RS SE]' FORTH B"¢ THE tdUNICZPRL. ZT"r' OF FtNC:HORRGE. ;2: :1: WILL ZNSTRLL THE S"r'STEM ZN RCCORDRNCE t.,IZTH THE C:O[)ES. 3: Z LINDERSTRND TFIRT THE ON-'-SZTE SEWER SYSTEM MR"r' REQUIRE ENL.RRGEhlENT ZF THE RESIDENCE ZS REMODEL. ED TO ZNCt..L.IDE MORE 'rHRN ~ E:EDROOMS. BORING NUMBERT'P-I Date Completed: ~- SOIL DESCRIPTION SILT ,,/.5o~E C. tAy LOCATION SKETCH No Scole EXPLANATION GROUND ~ ORCA NI_C MATERIAL t.itlle V,slble Ice 0:-I0' Vx -- "~ A B L--ICE DESCRIPTION ~1- Ss, 72,57 I°/o, 85.9 pcf I ~LO~'S/~OOT ~ ~0. ~ATER T~BLE ~EDROCK TYPICAL SOILS LOG I SAMPLER TYPE SYMBOLS SOIL SYMBOLS r- 0 ~N. L~ U LTA I~11".3, INC. SOILS LOG Al>ri[ 14, 1980 F,&H No. 051001-21 Omni North P.O. Bo× An('horag(,.~ Al~ka 99511 Subject: Soil Investigation for Sanitary Sewer System, Lot 10, Block 1, Highland Subdiv£sion, Anchorage, Alaska Gentlemen: At your request of April 9, 1980, we conducted a subsurface soils investS- gation at the proposed location of the sanitary sewer system on the subject lot. The investigati, on complied with those procedures required by the HunS cipality of Anchorage Department of ttealth and Environmental Protection. This investigation, which was accomplished on April 10, 1980, consisted of a test hole excavated to a depth of 16 feet below the existing ground surface. The test hole was s~ted accord5ng to your instructions and its location is shown in attached Drawing A-01. Excavation was accomplished with a backhoe. All material excavated was continuously monitored by an experienced engineerSng geologist. The topography at the excavation site is generally horizontal. AL the time of the invest5gation tim site had been stripped of vegetation. The soils encountered in the excavation are shown Jn the test hole log in Drawing A-OI. This log displays specific conditious encountered at the test location, floweret, suhsurtace conditions may vary in other parts of the lot without any apparent' sur['ic/al evidence of the change. Groundwater was not encountered and br~drock was not e,co,mtered. Seasonal frost was not present aad perma[rost was not en(ountered. Based on the visual classification of the soil and the requirements set forth by the Huncipal£ty of Anchorage, a percolation test was not necessary within the test hole on the subject We appreciated this opportunity to be of service to you. Please contact us £f you haw~ any quest, io,s concerning this letter or if we can be of addi- tional service. Very truly yours, R&M CONSUL'FANTS, INC. Janice Cecere ~ Project Manager JC/dj/ATSI-A April 16, 1980 Bill Breedlove Omni North Post Office Box 10-573 Anchorage, Alaska 99511 Subject: Lot 10, Block 1 Highland Subdivision Dear Mr. Breedlove: 338 Denali Street MacKay Bldg., Room 1206 Anchorage, Alaska 99501 (907) 274-5527 P.O. Box 1207 Soldotna, Alaska 99669 (907) 262-5210 P,O. Box 1064 ['] Wasilla, Alaska 99687 (907) 376-5038 MUNICIPALITY OF ANCHORAGE DEPT. ~7: ' ,', ENVIROF ,: , : TION RECEIVED We have reviewed the on-site soils information which was compiled by R & M Consultants on the subject lot. It is our understanding that you wish to construct an office facility which up to five (5) people will occupy. The on-site water and sewer systems are hereby approved for the features with which this department is concerned providing a separation of at least 120 feet is maintained between the well and any surrounding septic tanks and soil absorption systems. This will require that the well be located near the front of the lot and the sewer system near the rear lot line. The Municipal Department of Health and Environmental Protection (264-4720) must also issue a sewer system permit prior to installation of the system. They will also inspect the system as it is installed. Please feel free to contact me if you have any questions regarding our review of this proposal. Sincerely, James O. Starr cc: DHEP - Les Buchholz bi 18~06LH