Loading...
HomeMy WebLinkAboutHIGHLAND BLK 2 LT 15I(.I 2_3 ---~- oEk Z 0 MUNICIPALITY OF ANCHORAGE ~'-'~ O[N" DEPARTMENT OF HEAl.TH & ENVIRONIV1ENTAL PROTI:CTION ENVIRONMENTAL ENGINEERING DIVISION 825 t. Street - Anchorage, Alaska 99501 Telephone 264-4'720 ON-SITE SEWAGE DISPOSAl_ SYSTEM AND/C)f~ WELL INSPECTION REPORT LOCATION -- I DISTANCE TO: ] ~ I DISTANCE TO: I ~ ~ ~ To--lie to finisl) grade I ~¢~ Width ~ P I Type of crib Clib diameter ~-' Absorpti,~ ea Dwelling NO. OF BEDROOMS PERMIT NO. Inside length Width Liquid depth Dwelling PERMIT NO. Material Liquid capacity in gallons Nearest lot line %-rich width ~'O inches [Foundation ¢'~ Total length of lines Material beneath tile Depth PERMIT I~O. A ~ cf ~,~ ~, I-~,, Total effective absorption area PERMIT NO, Crib depth Total effective absorption area Buildin9 foundation Nearest lot line Driller Distance to lot line PERMIT NO. Sewer tine Septic tank Absorption area(s) OTHER PIPE MATERIALS Pvc SOIL TEST RATING /Sc, iNSTALLER REMARKS APPROVED DATE LEGAL MUNICIPALITY OF ANCHORAGE Department Health and Environmental 'rotection 825 L Street, Anchorage, AK. >~.501 264-4720 * * * HANDWRITTEN PERMIT * * * Permit ~ ~ ~~ ~--~-~:~t][7~R ON-S I TE SEWER PERM I T Location: Phone Number: Legal Description:~;'~ ~ Z ~/.~/~ ~/~, Type of Soil Absorption System Is: Lot Size: Trench: ~ Drainfield: Seepage Bed: Holding Tank: Maximum Number of Bedrooms: ~3~ Soil Rating{sq.ft/br) /~O DEPTH //. ~ The Required Size of the Soil Absorption System Is: LENGTH -~' GRAVEL DEPTH ~ WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = /~'~9 GALLONS * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required, and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 1 9 8 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is uemodeled to include more that 3 bedrooms. Date: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION [] PERCOLATION TEST 825 L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST PERFORMED FOR: DATE PE-RFORMED: SLOPE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15- 16 17 18 19 2O COMMENTS PERFORMED BY: 72-008 (6/79) 6~v'J SITE PLAN IF YES, AT WHAT DEPTH? .'; .,,,,..' .,.. . '- ~> .~,, ,~i;' ,~. . PER'COLATION RATE '" \ ~' '(mmu'tes/mch) TEST RUN BETWEEN ..,'FT .A.~I~) ~ -', ~- : ". -._~.',.,~,.,,,~! , ;2'"F~'%'~ .... ::'~.~'~.'~ I' CERT,~,EO."~': ":h~ ~ ,', "-" .':~' ' ~, '~:,, ..... .' ~',, ,, Gross Net Depth to Net Readin9 Date Time Time Water Drop DATE: ALASKA eFIUIROF1Frt F1TAL COFITROL IFIC. July 25, 1983 Department of Health and Environmental Protection 825 L. Street Anchorage, Alaska 99501 Attn: Laura Dear Laura: On June 21, 1983 we performed a soils test for Mike Rush on Lot 15 Block 2 Highland Subdivision. The soils test and the subsequent permit are in error. I am enclosing the soils test with the correct legal description. Please correct the handwritten permit. Sorry for the mixup. Sincerely, Leroy C. Reid Jr., PhD PE President M/JNICIPALITY OF ANCHORAGE DEPI. OF HFALIH ENVIRONMENTAL PROTECTION RECEIVED 1200 LUcsl 33rd Aucnu¢, Suite [~ · Anchora§¢, Alaska 99503 · (907) 276-~36~ SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAl_ PROTECTION 825 L. Street, Anchorage, Alaska 99501 264~4720 SOILS LOG - PERCOLATION TEST PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: SLOPE SITE PLAN 1 2 3 4 5 6 7 8 9 lO 11 12 13 14 15 t6 17 18 19 2O %¢ Gl. COMMENTS 72-008 (6/79) WAS GROUND WATER ENCOUNTERED? I~AT Gross Date Time Net Time Depth to Water Net Drop (907) 243-2282 KEN JOHNSON KEN'S COMPANY WATER WELL DRILLING PUMP SALES & SERVICE 30 YEARS ALASKA DRILLING 3163 LINDEN DRIVE ANCHORAGE, ALASKA 99502 SEPTE~BER 9, 1983 ( Hm. 243~7237... Wk. 563-3628~.,U)MC,PAU,~¢, , /, OF ANCHOZ,~.(~B DEPT. OF HEALTH & WATER WELL LOG ENVIRORM~NTAL PROTECT[O~ 0 ft to 3 ft 3:6t to 9 ft 9 ft to 27 ft 27 ft to 40 ft 40 ft to 47 ft 47 ft to 55 ft Fill Fine sand Med. sand and gravel ((try) Med. gravel, and clay Sandy clay Med. grave], and clay Olean med. Sand and gravel Water bearif~g Static 25 ft. 30 ft Head Test bailed one hour at 15 Drawdown to 40 ft. Good recovery Bottom Stable