ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: OSP111090 PID Number: 050-312-26
Theodore Schindler Wastewater System: [] New [] Upgrade
Address:
13111 Sues Way, Anchorage, AK 99516 ABSORPTION FIELD
Phone: Number of Bedrooms:
[] Deep Trench [] Shallow Trench [] Bed [] Mound [] Other:
LEGAL DESCRIPTION so, Rating: Total Depth from original grade:
0.8 GPD~Ft2 8.5
Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe:
6 Highland Terrace #5 3Ft. 5.5 Ft.
Township: Range: Sec[ion: Fill added above original grade: Gravel Length:
.5 Pt. 55
Well: [] New [] Upgrade Grave~ width: Number of lines: I Distance between lines:
2.5 Ft. 1I
Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material:
Existing Private Pt. .t. 605 pt2 3034 PVC
Driller: Date Drilled: Static Water Level: Installer: Date Installed:
Ft. Flintstone Enterprises 6/2812011
Yield: GPM Pump Set at: Casing Height Above Ground:
Pt. Pt. TANK
SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other:
T~To Septic Absorption Lift Holding ~ublic/PrivateManufacturer: Capacity:
From~
Tank Field Station Tank Sewer Line Anchorage Tank 1250Gal.
Material: Number of Compartments:
We~ 62.3* 110.0 72.0 42.7 Steel / STI P3 2
Surface Water 100+ 100+ 100+ ~ / LIFT STATION
Lot Line1.5'* 7.7 1.5~ S~ze: Man~ac[urer:
250 Sa~. Orenco/Anchroage Tank
"Pump on" level at: "Pump off" level at: in. High water alarm at:
Poundat~on 35.0 54.9 44.0 +40 ~n. +36 +45 ~n.
Cu.ain Drain NIA NIA N/A Pump Make & Model Electrical Inspections performed by:
P2005-1 .-T, ~-/-.gJ?--q~__~c. j L L,
Remarks:
*Waved to 60'. **1 request a lot line to septic tank distance BENCH MARK
Location and Description:
waiver of 1.5', and a lot line to drain field distance waiver of 7.5'. GAS METER/VALVE
Assumed Elevation:
100.0 Ft.
Engineer's Stamp
Inspections performed by: PANNONE ENG. SVC, LLC Dates: 1st 9/27/2011
2nd 912812011 ~.~;~ y). ................
Development Services Department Approve- -~- ...,~:.." ~.~
Conditional Approval Date: -~ ~'" 4~TH ~
........... ~ ..... ~"~"~t~'"""~ ........ '" .....
¥'..~ Oo No. CE c~149
aev e ,ed and approved by' 5 ff
A B C x '"~ ~ /
T1 56.750.2 ~ -~
T2 42.4 56.4 /7/. /
M1 68.5 59.8 ~'~'~-~~ W~N EXISTING
M2 108.8 82.2 ~ ~SEPTIC
CICUTTA WAY ~ AREA
NEW PRIMARY FIELD
_ ~ 55LF~5.~'EDx2.5'W. 8.5'TD
I '¢
~SEPTIC .~'~ X /
~..-.-. x" ......... T2: ~'" "~
NEW 12509-'~<(" '1 ~¢¢7'~"~"Z ~'US~ Z ~.~...,.~....,..~ .........
PAGE 2/3 ~, 62.3 · ~ ~EXlSTING
EXISTINOsEPTic'IOOOgTANK ~i ?~o ~WELL,-(E) ~,/ AREASEPTIC
ABANDON PER CODE N~
BY REMOVAL
AND DISPOSAL
DRAIN FIELD IN P~CE
NOTES: P~O~ ~G ~C, L~ ~ ~F Al ?~l Dote
~&~.N .... ~I~, ~/28/1~
RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 ~..
PHONE (907) 272-8218 F~X (907) 272-8211 ~ .- ~..W ~ Scal~
~,..'~ ~ ~ '..~ 1":so'
HIGHLAND TERRACE frS, LOT 6 ..... ~ 050-512-26
THEODORE SCHINDLER ~ ~~,~nno~e'~ PERMIT NO.
13111 SUES WAY-~' bE ~I~V ,~,~~} .~:~' 0SPl11090
PLAN ANCHORAGE, AK 99516 ~ Sheet
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE
STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE
WASTEWATER DISPOSAL SYSTEMS.
2. ALL WAS BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS.
5. SCOPE OF WORK: INSTALLED NEW 1250 GALLON S.T.E.P. TANK AND NEW SOIL ABSORPTION SYSTEM.
4. NO GROUNDWATER WAS OBSERVED AS EVIDENCED BY THE SOIL TEST HOLE. NO APPARENT WATER TABLE WAS
OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 14.5 FEET BELOW EXISTING GRADE.
5. TANK WAS COATED TO STI PS, UNDERGROUND FUEL TANK, STANDARDS WITHOUT THE SACRIFICIAL ANODE.
-- 6" TOPSOIL AND VEGETATION
Tm ..~ 99.7 (FO)
¢,/,M J ~ Ys" HOLES © 24" O.C.
~ ~-DRAIN ROCK
2.5
6.0
No groundwoter ~
monitored ~- 6" TOPSOIL AND VEGETATION
SECTION ° ~ / ~ ~,"0 PERF P~PE o
~ ~ B ~ -~ OO FILTER FABRIC
o o ~ 99.7 (FG)..~__ 99.7 (FO)
85.0-x I 90.7 ~ 90.7
-- · NEW 125~'gu TRENCH - SEE DESIGN
l S.T.E.~. PROFILE
TANK
*SEE NOIE 5, IHIS PAG£.
ABBREVIATIONS
DESIGN PARAMETERS cu COPPER
PRIMARY/RESERVE SEPTIC SYSTEM DIP DUCTILE IRON PIPE LEGEND
NO. BEDROOM: 5 (450 gpd) TH TEST HOLE --W WATER LINE/
TANK SIZE: 1250g S.T.E.P. FC FOUNDATION CLEAN OUT WELL RADIUS
PERC RATE = 1-5 MPI
SOIL RATING: 0.8 GPD/SF TI/ TANK CLEAN OUT NO.
AREA RQD: 562.5 SF CC/ CLEAN OUT NO. ~ SS NEW SEPTIC
SYS. TYPE: DEEP TRENCH 5.5' E.D. M# MONITOR TUBE NO.
MIN LENGTH: 51.1 LF R.I. RIGID INSULATION
DCO DOUBLE CLEAN OUT
USED: DV DIVERTER VALVE
55 LF X 2.5' WIDE, 5.5' E.D., FS FLOW SPLITTER
8.5' TD FO FINISH GRADE
TOTAL AREA: 605 SF OG ORIGINAL GRADE
RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 ~-~.::.'
~HONE (~07) 272-8218 ['AX (907)272-~211
HIGHLAND TERRACE #5, LOT 6 ~ ...... i ''''~ P.I.D. NO
-~ ~050-312-26
THEODORE SCHINDLER · ~ PERMIT NO.
DESIGN DETAILS ANCHORAGE, AK 99516 'li~"9,~;~k¥'S"O~x?~.~.~.~,~v,~o,~..~-~ Sheet
Jun ,'~ /U~'~ ~,~/~1 J L~c~'r.J~l~:~c LIe ~Jf-ffU4~-Jbb f;m~e ~
TD:272~211
P.1/1
J ELECTRIC ~,LC
6732 E. 99Ch AVE,.
ANCHORaGe, AK. 99507
June 27. 2011
JR'$ Septic Pu~ping
P. 0. Box 773415
Eagle River, Ak. 99577
1954&. Ctc~ltta~ Way
star*ion and al~o bmgk level, ala~ a= the a~eve ad~es~ ~
accordance with the ~C ~d MOA codeg.
J ELECT~C LLC
Contractors # 34469
Municipality of Anchorage
P.O, Box 196650 · 4700 Elmore Road
Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997
http:llwww.muni.or.qlOnsite
Development Services Department
On-Site Water and Wastewater Program
~epartment
**** VARIANCE/WAIVER REVIEW ****
WR#: OSPl11091
PID#: 050-312-26
Legal Description: Hi.qhland Terrace #5
Engineer: PES
HA#: OSCl 11225
Lot 6
Permit#: OSO111090
Applicant: Theodore Schindler
Your request for a waiver of the required 10 feet horizontal separation from the absorption field
to the property line has been approved. The approved separation distance is 1.5 feet.
This waiver approval applies to the existing absorption field to property line separation only.
Any future upgrade to the on-site wastewater disposal system will require all separation
distances be met or another approval from this department. Add comments / explanations or
DELETE
Waiver is Granted: X Waiver is not Granted:
Date: 6/29/2011 Approved by: &~/~/~"'/'
. ~-/ma~~ewer
Rec#: Amount: Date Paid:
**** VARIANCE/WAIVER REVIEW ****
Permit Number: OSPl11090
Tax Code Number: 05031226000
Work Type: Septic
Permit Effective Dates: June 15, 2011
Design Engineer:
Subdivision:
On-Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Upgrade
to June 14, 2012
PANNONE ENGINEERING SERVICE
HIGHLAND TERRACE #5
Site Legal Address: HIGHLAND TERRACE #5 LT 6 G:0155
Owner/Address: SCHINDLER THEODORE J &
TERESA A 13111 SUES WAY ANCHORAGE AK 995162641
Site Mailing Address:
19544 CICUTTA WAY, Eagle River
Lot Size in Sq Ft: 56236
Total Bedrooms: 3
/c"' cO
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection· Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By: ~
Issued By:
Date:
Date:
Municipality of Anchorage
P.O. Box 196650 ® 4700 Elmore Road
AnChorage, Alaska 99519-6650 ® (907) 343-7904 · Fax (907) 343-7997
httl~://www.muni.or~lOnsite
Development Services Department
On=Site Water and Wastewater Pro.qram
epartment
**** VARIANCE/WAIVER REVIEW ****
Waiverg: OSP111091 COSA#:
PID#: 050-312-26
Legal Description: Hi.qhland Terrace #5 Lot 6
Engineer: PES
Permit-g: OSP111090
Applicant: Theodore and Theresa Schindler
Your request for a waiver of the required 100 feet horizontal separation from the S.T.E.P. tank to
the private well has been approved. The approved separation distance is 60.0 feet. The existing
tank has been in the same location for 34 years. Water sample is negative for total coliform and
only .413 mg/L of Nitrates. The new tank will have the STi-P3 coating.
This waiver approval applies to the proposed S.T.E.P. tank only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
Waiver is Granted: X Waiver is not Granted:
Date: ~2>/~/~' Approved by:
' Name of Reviewer
Rec~: 083325 Amount: $1,050.00 ' Date Paid: 6/1/11
**** VARIANCE/WAIVER REVIEW ****
UNICIPALITY OF
ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Mayor Dan Sullivan
~ Phone:907-343-7904
Fax:907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. (:~'~-3i2--
Property owner(s) -1"1-/~ ~2¢-~ ~t.~ 1'~¢46-54
Mailing address ('.~ [I ~ ~------------------~-~. i,d'~ ~(
Site address I~/~,.:/z./ (21c.O'T"r'~ c0.~ ,¢
Legal description (Sub'd., Block & Lot) ./¢../~[¢LR,v'.O
Legal description (Township, Range & Section)
Lot Size ~'~ ~-_;~ ~, Sq. Ft. Number of Bedrooms
Day phone
THIS APPLICATION IS FOR:
([~ all that apply)
Absorption Field ~
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I cedify that the above information is correct. I fudher cedify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
(signa~&e ~f propeh~ owner or authorized agent)
~----~Rush Fees: ~ --
--Date of Payment: (~ - ~'- ~
Receipt Number: ~' ~"~ ~
Permit No. ~--'~t¢[!! E) c~o
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
G:\Building\On Site\Forms\CIient Forms\Permit App_010411 .doc (Rev. 1/11)
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panenRak.com
June 14, 2011
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
4700 S. Bragaw Street
P. O. Box 196650
Anchorage, Alaska 99519
Subject:
Highland Terrace #5, Lot 6
Septic System Permit Upgrade Request, Revised
Ladies and Gentlemen:
I am writing to request a permit to construct an upgraded septic system be issued for this property. The proposed
systems will serve an existing three-bedroom house. Currently the lot is developed. The lot is served by a private
well. The existing septic system is in failure. The surrounding lots are served by private wells.
1. Soils. A single test hole was excavated by Pannone Engineering Service in May of 2011. See the soil log
attached. Ground water was monitored for seven days. No ground water was monitored to a depth of 14.5 feet
below ground level after the monitoring period. Bedrock was not encountered in the test hole. It is my opinion,
based on the results of the percolation tests and overall soils appearance; an application rate of 0.8
gallons/day/square feet should be used, using a 1,250 gallon S.T.E.P. tank and deep trench type drain field.
Soil Absorption System Design.
a. See Sheet 2 of the design package
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and the existing drain
field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches.
4. Topography: The topography in the area slopes generally from north to south. There is a high relatively
flat area where the purposed drain field will be located. Just uphill from the tank there is a fill slope that is over 50
feet from the purposed drain field.
So
Waiver Request: I request the following waiver:
a. Well to Septic Tank/Lift Station from 100 feet to 60 feet.
The existing drain field serving this lot is located over the property line and is in failure. It is located approximately
90 feet from the well. The existing 1000 gallon tank is located 63 feet from the well. Both will be abandoned per
code. A water sample was taken and analyzed on May 6, 2011 and found to have nitrates of 0.413 mg/L. The
purposed S.T.E.P. tank will be located 60 feet from the well, and will be coated to STi-P3, Underground Fuel Tank
Standards, minus the sacrificial anode. There is an area to the south west of the well that is outside the well radius.
We looked at installing the system in this area and found it unsuitable for the following reasons: 1) The well is 24 feet
Page 2 of 2
from the house, there is not enough room to install a sewer line outside the 25 foot protective radius. It is easier to
control the coating on a tank, than to protect the raw sewage line from leaking; 2) The area slopes at approximately
six percent and the proposed tank and drain field would not fit in this area and meet code; 3) installing a S.T.E.P. tank
in this area would require pumping the effluent approximately 300 feet, uphill and across a drive way. There would
be possibilities of freezing and clogging over that length. The soils we encountered in the area of the drain field
(uphill from the tank) were sandy, gravely, silts to 14.5 feet below ground with a percolation rate of 3.8 minutes per
inch. The ground at the tank is located approximately level to the ground at the well casing and contamination is
unlikely. The well is located on the southern portion of the lot. The static water level in the well is 220 feet below
the top of the casing (218 feet below ground level). The hydraulic gradient is 6 to 7 percent from northeast to
southwest. Approving the waiver will not create a health problem for this or the surrounding lots.
In review of the ADEC Waiver Memorandum the following points are tabulated:
Section Points
Water Table (220 ft) 8.5
Soil Sorbtion (Silty Gravel / bedrock) 4.1
Permeability 1.0
Water Table Gradient {-0.5%) 2.0
Horiz. Separation (60ft) 1.5
Total 17.1 points
16-25 points: Almost sure to be free from any form of contamination from household sewage.
6. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the
review is complete and that there are no further comments is received from MoA On-Site Department, the note will
be removed and "Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of the surrounding or existing lots. There are no
wells or septic systems within 100 feet of the proposed septic location.
If you have any questions or concerns, please contact me at 272-8218.
Sincerely,
~.....[..~...~..~;.. ~
~.....~: .................................. ? ".
Steven R. Pannone, P.E.
Owner/Civil Engineer
Attachments
Mailing: ?~0~ Bo){ 100217, Anchol'age~ At{ 99510-02i?
Te{ephone: (907) 272-82t8 FAX: (907} 272~g211
~ ~"~-~~ w
~ ,/--SEPTIC
ClCUTTA WAY ~ AREA
PRIMARY FIELD (P) ~.
~ 55LFx5.5'EDx2.5"W, ,.8~TD ..... ~
,N /
PAGE 2/3 60't ~ , ~EXISTINO
~ / ~ ~ WELL (E) ~ SEPTIC
EXISTING lO00g ~1 ~ ~ AREA
SEPTIC TANK ~ ~/
ABANDON PER CODE
~ABANDON EXISTING
DRAIN FIELD IN P~CE
NOTES: P~O~ ~G ~C, L~ ~ ____, ~ Date
PHONE (907) 272-8218 tAX (907) 272-8211
PLAN ANCHORAGE, AK 99516
1 OF3
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON-SITE WASTEWATER DISPOSAL SYSTEMS.
2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS.
3. SCOPE OF WORK: INSTALL NEW 1250 GALLON S.T.E.P. TANK AND NEW SOIL ABSORPTION SYSTEM.
4. NO GROUNDWATER WAS OBSERVED AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS
OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 14.5 FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER
IMMEDIATELY.
5. TANK SHALL BE COATED TO STI PS, UNDERGROUND FUEL TANK, STANDARDS WITHOUT THE SACRIFICIAL ANODE.
CONTRACTOR SHALL PROVIDE WRI~EN VERIFICATION FROM MANUFACTURER.
-6" TOPSOIL AND VEGETATION
0.5
'*'~ (~ ~-FILTER FABRIC
X-DRAIN
6.0
No ~roundwoter
monitored~,,<,~ °z /- 6" TOPSOIL AND VEGETATION
SECTION o ~ /
4.0
NEW 1250 g TRENCH - SEE DESIGN
S.T.E.P. i PROFILE
TANK
*SEE NOTE 5, THIS PAGE.
DESIGN PARAMETERS
PRIMARY/RESERVE SEPTIC SYSTEM AB B R EVIATI 0 N S LEG E N D
NO. BEDROOM: 3 (450 gpd) CU COPPER -- W WATER LINE/
TANK SIZE: 1250g S.T.E.P. DIP DUCTILE IRON PIPE WELL RADIUS
PERC RATE = 1-5 MPI TH TEST HOLE
SOIL RATING: 0.8 GPD/SF FC FOUNDATION CLEAN OUT ~ SS NEW SEPTIC
AREA RQD: 562.5 SF TiC TANK CLEAN OUT NO.
SYS. TYPE: DEEP TRENCH 5.5' E.D. CiC CLEAN OUT NO.
MIN LENGTH: 51.1 LF
M# MONITOR TUBE NO.
USE: R.I. RIGID INSULATION
55 LF X 2.5' WIDE, 5.5' E.D., DCO DOUBLE CLEAN OUT
~o~'.~!~ TD ~' ~, ¢.¢. DV DIVERTER VALVE
TOTAL AREA: 605 SF FS FLOW SPLITTER
NOTES: PANNONE ENG SVC, LLC
FOR CONSTRUCTION p.O. BOX ~00217 ANCHORAGE, AK 99510
NTS
P.I.D. NO
HIGHLAND TERRACE #5, LOT 6 050-312-26
THEODORE SCHINDLER . CE ~149 .~',~-~ 0SPl11090
20F3
SOILS LOG - PERCOLATION TEST
TEST HOLE 1
()N TOPSOIL SLOPE ~:'~ ~'r~['SITE PLAN~
5 -- " ' "' ~' GB ..... "" ' GB -..
6--
SANDY /
7 -- GRAVELY
8 -- LARGER TH
9 -- DEPTH
12 --, ~ ........ ? ............. '?' ......... ',r ........ S E
13 -- ,,,
WAS GROUND WATER SLOPE
14 -- ENCOUNTERED? N
15 -- BOH
IF YES, AT WHAT TH
16 -- DEPTH? -0-' X
17 -- DEPTH TO WATER AFTER
MONITORING? -DRY-
18 DATE: 5/18/11
DATE PERFORMED: 5/11/11 READING DATE CLOCK WATER
TIME NET TIME LEVEL NET DROP
READING
I 5/11/11 12:07 --- 5.17 ---
2 12:17 10 MIN 8.03 2.80
3 12:17 --- 5.17 --
4 12:27 10 MIN 7.81 2.64
; 5 12:27 .... 5.17
6 12:37 10 MIN 7.75 2.58
PEROLATION RATE 3.8 (min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 5 FT AND 6 FT
COMMENTS: Test hole excavated by SOUTH FORK CONSTRUCTION. Prec hole was presoaked~
Test run for one hour. Last 3 readings reported
PERFORMED BY: Steven R. Pannone~ P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
~~.~. D a t e
NOTES: PANNONE ENG SVC, LLC ~.~,.. 9.~. .~,.L~ ~,, 6/14/11
,=~,'t. ~.;c.^, R~-VlEW 0::':,' P.O. BOX 102954 ANCHORAGE, AK 99510 ~'c_~.~.''
~ C~x),-.~"r'iP--I,~'7'¢'~,,~ PHONE (907) 272-8218 FAX (907) 272-8211~ --".'~'*."'4c~ TH ~...,~
Scale
NTS
P.I.D.
NO
...... 050-312-26
THEODORE SCHINDLER ~'~,~ ¢~e ve ~EIX ~ lh'4~n n .°.-~ ~ PER M I T N O.
15111 SUES WAY ,~.. ..~,~,~x~___~,.~ 0SPl11090
SOILS LOG ANCHORAGE, AK 99516 ti~.~OF[SS\O~?_~,~ ~'~"" Sheet
READING DATE CLOCK WATER
TIME NET TIME LEVEL NET DROP
READING
1 5/11/11 12:07 --- 5.17 ---
2 12:17 10 MIN 8.03 2.80
3 12:17 --- 5.17 --
4 12:27 10 MIN 7.81 2.64
5 12:27 --- 5.17
6 12:37 10 MIN 7.75 2.58
~.i~-.~ GRE~, ER ANCHORAGE AREA BOR~.UGH
~ ~ )~ Department of Environmental Quality
3330 C Street
(Z ~ ~-~ f][O ~ Anchorage, Alaska 99503
INSP~C~O~ REPORT ON-SITE SEWAGE DISPOS~. SYSTEM
SEPTIC TANK:
DISTANCE -'~.~ /
FROM WELL (~"/ MANUFACTURER ___ ~'""~' MATERIAL
INSIDE LENGTH ,/' INSIDE WIDTFI ""/ LIQUID DEPTH
~ COMPARTMENTS --
LIQUID C APAC I TY [0 ~) ~"E~AL LON $.
TILE DRAIN FIELD:
/
DISTANCE FROM WELL ~'-~--~ ~'~--FOUNDATION
NUMBER OF LINES DISTANCE BETWEEN LINES __ TRENCH WIDTH IN.
DEPTH: TOP OF TILE TO FINISFI GRADE ¢
q¢__NEAREST LOT LINE
TOTAL LENGTH/
OF LINES
DEPTH OF FILTER
MATERIAL BENEATH TILE
TOTAL EFFECTIVE
{,~0 '
IN. ABOVE TILE .~' IN.
WELL: ~
TYPE 'd[~,/)~ '/~ ['C¢- ~J/ .... CONSTRUCTION
BUILDING NEAREST
FOUNDATION__ LOT LINE__,
CESSPOOL OTIHER SOURCES
APPROVED DISAPPROVED
NEAREST
SEWER LINE
DEPTH ........ DISTANCE FROM:
SEPTIC SEEPAGE
TANK __, SYSTEM
REMARKS
DISTANCES: ~ _
INSTALLED BY: ~~ '
SEWER LINE DEPTH:
PIPE MATERIAL: (~'
DIAGRAM OF SYSTEM
, ~.,, ~ '~.~ _~_ 7o'___._~--.--~O.~eJl
~or L, ~ ~ ~- - ~ ,
I:::11::'I::'1,. :1: I:::: I:il",l '1"
f. IZI I:'::1:::1'1" :1: O I",t
I.., 1:!!: (:!il:::tl .,,
I..E; I'"I:I:GHt...I::II",!t) 'i"I!!i:I:;i:I:'::FIE:E: .t.I.
::L: :1: I:::11"'1 I:::'l::'ll'"J:l:l...:l:f::ll';i: I.'.I:I:'TH 'l'Hli~: F'.l:ii:QLl:[t:;?.E:t"'lE:l",t'l"'.iii; I::'Efl;i: OI",t-'t!i;:[TE: :fi;[:::l,.llii:l:;?.:i::; I:::IH[Z:' l.'.tl{:i:I..l. :i: l:::l:i!i;
I:::'OI:;i:'FH Iii?,"? 't'HI!!: Ifil N'I'-: I:::'1:::11 'l"l'"r' FI:::' :.:ll'.,Ir":l.l~"l:;'l:::lr:il:!:'
;i?: :lZ I.,.I :1: I..I... :[ I'.,l:i!i;'l"l:::ll...I... 'l"Hlili: :ii!;'.r'r!~:;TE:H :[ t'.,I :::::::::::::::::::::::::::::::::::::::::::::: I.,.I :1: "I'1.t t"l.llii:
:::i:: ]: I..IJ,,l[::,Iii~l:;i::iil;Tl:::li'.,Jl:::, I'HI::II' 'l"l..lliii: Ol'.,I...:!ii;:l:"l"E: iiii;l!ii:l,.![ii:Fi: :!!i;"r':iiiFl"l!ii:l"l I"ll:::l"r' I:?. li!i: C! l. .l :l I:;?.liii: E:I,,II.I:::iI:;irGI!~:I','Ili!!ZI'.,Fr' :lZl:::
t:~'.E::i!i;:I:I:::,I~i!:I'.,ICE: :l:tiil; I:;i:lii:l','lO[::,l:ii:l.lii~lZ::, "t'~:::~ :ft'~!~::[.l..llZ::,t!i: I"'tOl:;?l!i: 'I'HFiI'.,! ::i!:
1::~1::'t:::'1.r · ' d~:l: ::::FiN"I' ~:1..~;'t' :[ ::. H :::
O 8- E GFO'
'CHNICAL 8- DEVEL
Box 90, Davis St., Eagle River, Alaska 99577
6952774 or 688-2280
?MENT CO.
Russell Oyster Earl EIh~
694-2774 SOIL LOG 688-2280
Soils ~ Foundations Land Development
Performed for:
Mailing Address:
D~~ S~ Characteristlc~
0
7~
8
9 ,~
10
Ground Water Encountered: Yes No
Proposed Installation: Seepage Pit
Com~lents: ---/
If yes, wh~t
Drain Field
0
13' W
294.7
I~ '~ o ~ L'~
It, d_ k-! ~-~,~ ~ ~1..
I~ O~ ~ ~ o~ O ~H
' /~ ~ ~L~
~ 0~ H
~ H
~ o
o
30f
ROM
MUNICIPAUTY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Section Phone., 907-343-7904
Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 050-312-26-000
Expiration Date:bec 16 .acoc-�
I. GENERAL INFORMATION
Complete legal description Highland Terrace #5 LIS
Location (site address) 19544 Cicutta Way Eagle River, AK 99577
Current property owner(s) Austin Gillette Day phone
Mailing address 191544 Cicutta Way Eagle River, AK 99577
Real estate agent
2. TYPE OF DWELLING:
P Single Family (w/wo ADU)
El Duplex
n Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
❑
Private Septic Ej
Water Storage
0
Holding Tank
Community Well
171
Community ❑
Public Water System
❑
Public Sewer ❑
VVaiver request ;or:
Distance:
Received by:
Date:
Cos t' be to be released to the engiree,unless rolherlwis.
leMI-1.11 1-.
quested by the engineer,
COSA Fee $ Waiver Fee $
Date of Payment Date of Payment
Receipt Number
Receipt Number
COSA#. C)5C2)j_r
)0'
-b Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures
outlined In the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or
wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated
herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with ail applicable Municipal and State
codes, ordinances, and regulations in effect at the time of installation.
In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MOA
COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time
of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on
the local soil condition; ground water levels that may fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not
guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot
provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole
benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly
recommends buyers hire their own engineer to evaluate this report.
Name of Firm Pannone Engineering Services Phone (907) 745-8200
Address P.O. Box 1807 Palmer, AK 99645
Engineer's Printed Name Steven R. Pannone P.E.
6. DSD SIGNATURE
I/ System #1 Approved for 2 bedrooms
System #2 Approved for _ bedrooms
Disapproved
Date
Conditional approval for bedrooms, with the following stipulations:
By;'t ((fJ( Q17lL.c G� Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineers work,
ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA CheMisl blue sheet
Legal Description: Highland Terrace #5 L6
If more than 1 septic system on lot: COSA Checklist # 1 of 1
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled unknown
Total depth 45+ ft
Cased to 40'+ ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) 12+ in.
Date of flow test for COSA 8/28/20
Static water level at beginning of test 118.5 ft
Comments
B. TANK DATA
Age of tank(s) 9 years
Tank type/material Step/Steel
Measured operating fluid level in septic tank 48
❑ Standpipes/foundation cleanout per record drawing
Date of pumping 9/10/20
D. ABSORPTION FIELD DATA Deep Trench
Which system tested (date installed) 2011
On ALL standpipes present per record drawing
Total measured depth from grade 10.25* ft (max)
Measured depth to pipe invert from grade ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Comments/Deficiencies: '+/- 2.0' fill added over the top of the drain field
COSA Checklist yellow sheet
Parcel ID: 050-312-26
Structure served by this system 1
Well production at time of test 2.7 gpm
Water storage tank volume n/a gallons
Well disinfected for coliform test? ❑ Yes No
❑ Coliform bacteria is Negative
Nitrate 2.43 mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by Pannone Engineering
Date of Sample
9/2/20
C. LIFT STATION
❑ Required maintenance completed
Age of lift station 9 years
Lift station material Steel
Comments:
Adequacy test date
8/28/20
Results Q Pass
For 3 bedrooms
Fluid depth prior to test 0/0 in
Water added 452
gal
New depth 9/7 in
Elapsed time 240
min
Final fluid depth 0/0
in
Absorption rate -"40u gpd
Any rejuvenation treatment (past 12 months) no
If yes, enter date
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
62.3
Community Sewer Manhole/Cleanout > 100'
f7 Yes
if No
ft
[❑✓ Yes
if No ft
Neighboring Tank > 100' M Yes
if No
ft
Private Sewer/Septic Line > 25' ❑ Yes
if No ft
Absorption Field on Lot > 100' M Yes
if No
ft
Holding Tank > 100' ❑✓ Yes
if No ft
Neighboring Absorption Fields > 100'
If septic tank is under driveway comment below
Surface Water > 100'
Animal Containment > 50' ❑✓ Yes
if No ft
0 Yes
if No
ft
waivers on file with MOA for separation distances
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ❑✓ Yes
if No
ft
0 Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10' Yes if No ft Surface Water > 100' ® Yes if No ft
15
Property Line > 5'
❑ Yes
if No •
ft
Wells on Adjacent Lots:
Absorption Field > 5'
0 Yes
if No
ft
Private Wells > 100' M Yes if No.
Water Main > 10'✓❑
Yes
if No
ft
Community Wells > 200' 0 Yes if No
Water Service Line > 10'
Q Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
E] Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
❑ Yes
if No 7.7
ft
Wells on Adjacent Lots:
Water Main > 10'
❑ Yes
if No
ft
Private Wells > 100' E1 Yes if No
Water Service Line > 10'
M Yes
if No
ft
Community Wells > 200' 121 Yes if No
Surface Water > 100'
0 Yes
if No
ft
F. ENGINEER'S COMMENTS
waivers on file with MOA for separation distances
G. ENGINEER'S CERTIFICATION
l certify that l have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
`" �Il s
•
COSA Checklist yellow sheet
ft
ft
10
ft
IVIUNK"A""IPALITY. OF ANCHORAGE
D&w-.)1oj-,.-)rnent 3(.-.,rvices Deparl.nnent
9011-34'-7004
Phone . 1)
On-S�te \A./a1`E-,,r & 'V,Jasiewaer St,.,,Nion -7
Lift Station/Pump Vault
Maintenance Log
Owner—A Street Address
Septic Tank:
-Sludge level nches -Pumping: required e -Pumping completed
rY9LJh_o
Lift station:
-Pump basket cleaned De no -Effluent filter cleaned e ` no
-Control floats cleaned4-Proper float settings confirmed <Aj:) no
�no �o
-Operation satisfactory e no
Alarm System:
-Dedicated electrical alarm circuit e ��)n o -Audible and visual alarm inside dwellin<_p��' no
-Alarm system operation s tisfaciol- ot satisfactory
Manhole Riser
-Ground water intrusion at riser to tank connectionyes
no
-Ground water intrusion around pipe penetrations es n6' -Weep hole functional iLno
-Manhole lid: Functionalfes' no Insulated (yg,!�,, no Properly Secured &�S�, no
Other
-All manufacturer required inspections and maintenance complete es no
Qualified Maintenance Provider:
/ , -
Technician Date of maintenanceUt
Company
Signature— 11�741,1,4�4 D a t 9L� 0a,
- V
Municipality of Anchorage
Development Services Department
Bui dng Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
(907) 343-7904
www. muni.org/onsite
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. o5o-3~-2-z6
GENERAL INFORMATION
Complete legal description Highland Terrace #5, Lot 6
Location (site address) ~9~4.¢ Cicutta Way, Eagle River
Expiration Date: fi" 2. ¢1 - i i
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Theodore Schindler
Day phone
! ~-PLr~T'o,~,, O~A;
Day phone
Real Estate Agent
Mailing Address
Unlegs otherwise requested, COSA will be held by DSD for pickup.
2¢':: ,NUMBER OF 'BEDROOMS: 3
3. :: TYP~ 0F WATER ~UPPLY:
InldivJ,dUa/;"",W~., []
.Individual Water Storage []
Community Class ~ Well []
Public Water System
Day phone
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding Tank
Community On-site
Public Sewer
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of.bedrooms and type of structure indicated herein. I further verify that b,ased on the information
obtained from the Municipality of Anchorage files and from my investigation and insp~C~ion, the' on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Pannone Engineering Services, LLC
Phone 272-82:1.8
Address P.O. Box :too2~7, Anchorage, AK 995~o
Engineer's Printed Name Steven R. Pannone, P.E.
Date 6/28/2o~
Engineers Comments: In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in
accordance with MOA DSD Guidelines & Regulations. The reported results describe the performance of the system under the conditions
encountered at the time of the test, and separation distances measured to readily identifiable features.
The operational life of all wells and septic systems depend on the local soil condition, ground water
levels that may fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of this system. All systems eventually fail and
satisfactory test results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. PES can therefore not provide any warranty for future
performance nor give any estimate of how long the system will continue to meet the operational
requir, ements qfthe MOA DSD. The content of this report is for the sole benefit of the owner listed
above. Any reliance upon or use of this report by any other person or party is not authorized nor will it
confer any legal right whatsoever..
5. DSD SIGNATURE
~,~"~ Approved for _'~ bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
(Rev. 11/0
X
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date: ~_~ - ,~,- ~-//
Municipality of Anchorage
DevelOpment Services Department
Building Safety Division
On-Site Water & Wastewater program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99~,19-6650
www. m u ni.org/~)~nsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST'
Legal Description: Highland Terrace #5, Lot 6
A. WELL DATA
Parcel ID: o5o-~.2-26
Well type Private
Date completed U/~.,ui~
Total depth~:~'
Date of test
Static water level
Well productiOn
IfA, B, or C provide PWSID
Sanitary seal (Y/N)
Cased to ~ft.
FROM WELL LOG
,,°)
g.p.m.
WATER SAMPLE RESULTS:
Well Log (Y/N) N
Wires properly protected (Y/N)
Casing height (above ground)
AT INSPECTION
r;Ir;1201~.
221 ft.
~..2 g.p.m.
in.
Coliform Ne9 colonies/100mL
ArseniC: ND ug/I
SEPTIC/HOLDING TANK DATA
Nitrate o.~,~ mg/L
Date of sample: r;16f, o~.~.
Collected by: DRM
Tank Type/Material Anchorage Tank/Steel
Tank size ~25o S.T.E..P. gal. Number of Compartments
Foundation cleanout (Y/N) Y_ Depression over tank (Y/N) N
Date of pumping &/~.W,/'.~_ Pumper
C. ABSORPTION. FIELD DATA
Date installed
Cleanouts (Y/N) Y
High water alarm (WN) Y
Date installed 6~'28~'2Oll
Length
Total depth 9 ft. Eft. absorption area 605 ft2
Date of adequacy test New Results (Pass/Fail)
Fluid depth in absorption field before test ~ in.
Elapsed Time:
Any rejuvenation treatment (past 12 mo.) (Y/N & type)
Soil rating (g.p.d./~ or ~/bdrm) 0.8
Width 2.5
Monitoring tube Y
Water added
in.
System type Deep Trench
Gravel below pipe 5.5
DepressiOn over field N
For ~ bedrooms
~ gal. New depth
Absorption rate >=
If yes, give date
in.
g.p.d.
LIFT STATION
Date installed 612812o3.3.
"Pump on" level at ~ in.
Datum Bottom
E. SEPARATION DISTANCES
Size in gallons 250
"Pump off' level at 3~ in.
Cycles tested /'q~
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tankJlift station on .lot 62.=~
Absorption field on lot ~.3.o.o
Public sewer main 75+
Sewer/septic service line ~2.7 ,
Animal containment areas 50+
Manhole/Access (Y/N) Y
High water alarm level at/~5
Meets alarm & circuit requirements? Y
in.
On adjacent lots 3.00+
On adjacent lots 3.00+
Public sewer manhole/cleanout 3.00+
Holding tank ~.oo+
Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 35.0 Property line
Water main 3.0+ Water service line
Wells on adjacent lots
Water Service line 53.8
Curtain drain 50+
F. COMMENTS
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 7.7* Building foundation ~,.._cj
Surface water 3.oo+
Wells on adjacent lots 3.0o+
Absorption field 57.6
Surface water 3.oo+
Water main 75+
Driveway, parking/vehicle storage
I request a lot line to septic'tank distance waiver of 1.5', and a lot line to drain field distance waiver of 7.5'.
I ce~i~ that l have determin~ though field insDections and ~. ~.:' ~ '.~. ~
rew~w of Municipal taco,s that th~above sys'tems are in ~ *~", '49~ ~ '*? ~
conformance w~h MOA COSA guidelines in effect on this date. ~'~'~~
Engineers Printed Name Steven R Pannone, P E ~~~;'~
Date ~1~1~.. '*~"'.. ........ ~'"~'~
COSA Fee $
Date of Payment
Receipt Number
(Rev. 11/05)
Waiver Fee $ ;~C~t
Date of Payment ~ - ~ - ({
Receipt Number (~)~' ~'-~ c~
SGS ReL# 1111739001
Client Name Pannone Eng. Srv. Printed Date/Time 05/16/2011 13:42
Project Name/// 19544 Cicutta Way Water Sample Collected Date/Time 05/06/2011 11:30
Client Sample 1D 19544 Cicutta Way Received Date/Time 05/06/2011 12:05
Matrix Drinking Water Technical Director Stephen C. Ede
PWSID 0
Sample Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Metals b~, ICP/MS
Arsenic
ND 5.00 ug/L EP200.8 C (<10) 05/09/11 05/09/11 NRB
Waters De,oar tment
Total Nitrate/Nitrite-N
0.413 0.100 mg/L SM204500NO3-F B (<10) 05/10/11 AYC
Microbiolog~r Laborator~r
E. Coli
Total Coliform
Negative I 100mL SM20 9223B A 05/06/11 DSH
Net~ative 1 100mL SM20 9223B A 05/06/11 DSH
Cl CUTTA ~,4 y
Lot 7 ~
CLEANOUTS
6.6' CANT--,.....
-..,
WITH DECK BELOW
PLOT PLAN
-SEPTIC
MANHOLE
/
I ~0(
\
Lot 1
WELL
DECKx 12~2'
STORY \\
RESIDENCE
WITH BASEMENT
Lot 6
56,236 s.f. /
,/
S 89'58'00"W 180.00'
\~-[.. ~ Lot2 j
SUBD1
E47~ ~WEST
AS BUILT X SCALE 1" = 50' GRID NW 155
Lot 5
Lot 5
Project No. 11-088
Lo ng (907) 522-6476
Registered Land Surveyors (907) 522-4625
ken{Hangsurvey.corn / JonathanOlangsurvey.com
& Associates, inc. 11500 Daryl Avenue, Anchorage, Alaska 99515-5049
Phone
Fax '=~'"~ O ~' A /'%%.
e'~;': .............. r ..... ~'::~'~
VJ ~ * "
I hereby certify that I have surveyed the following described properly:
Lot 6, Highland Terrace Subdlvislon Addition No. 5 (Plat No, 75-12)
Anchorage Recording DlsfHcf, Alaska, and that the Improvements situated thereon are
within the properly Ilnes and do not encroach onto fha properly adjacent thereto, that
no Improvernenfs on the property lylng adjacent thereto encroach on the surveyed
premises and that there are no roadways, fransrnlsslon lines or other visible
easements on said property except as Indicated hereon.
Dated thls the ?~% Day of _ _~J.t~ ........... '~L\ , af Anchorage, Alaska
If Is fha responsibility of the owner to determine the existence of any easements,
covenants, or restrictions which do not appear on the recorded subdivlslon plat.
Aarow Pump & Well Service LLC
(907)346-9355
Inspection Report
I ran a camera 45' down the well at 19544 Cicutta Way, Eagle River
and did not find any holes/cracks in the casing or leaking around the pitless.
Beau Maxim
Parcel I.D.
1.
MUNICIPALITY OF ANCHORAGE
DE"PARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmentar Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
GENERAL INFORMATION
Complete legal description L-~'T'
Location (site address or directions)
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
HAA # "~1 ~-~X~
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS: '~"
TYPE OF WATER SUPPLY:
Individual well
Community well
Public water
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site /~ .
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. 1191) Front MOA ~21
Legal Description: ~,J:)'~-"~ APD~I .%- !-!!6l~(,J~Jb 'T'~_~ .,~-? Parcel I.D.'
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
Environmental Services Division
825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744
Health Authority Approval Checklist
A. WELL DATA
Well type ?¢._{~-'[~'~ If A, B, or C, attach ADEC letter, ADEC water system number
Log present (Y/N)
Total depth "2--I
Sanitary seal (Y/N) ~1~
Date completed .\/JEJ..C PUT !Al [<~¢ ~
Cased to ~>~ftt~ ~'~J-O _ Casing height (above ground)
Wires proPerly protected (Y/N) __~)
II
FROM WELL LOG
AT INSPECTION
Date of test
Static water level
Well production
g.p,m,
WATER SAMPLE RESULTS:
Coliform ~;)
Date of sample: ,'%E.P'T" ~'~
SEPTIC/HOLDING TANK DATA
. Nitrate
0,.737
Collected by: "~h
Other bacteria
Date installed
Foundation cleapout (Y/.N) _
Date of pU 'roPing --~., t z-~(¢{~
C. ABSORPTION FIELD DATA
Tank size ~ Number of Compartments _~__ Cleanouts (Y/N)~
Depression (Y/N) ~[ . High water alarm (Y/N) _/V~
.Pumper ~-?_.{~ PO:~,I,~(_.~
Date ih. stalled,. Iq'7 :;7. Soil rating (g.p.d,/fF or fF/bdrm) ~/ . System type _
Leng~/'.~?' "Width, . ~- Gravel thickness below pipe~ ~_ Total depth
E~ectlve able r ~l~[ ~a ~ ~ ~) ~ ~ [ Monitoring Tube present (Y/N) ~) Depression over f e d (Y/N) _._~__.
Date of ad.qu. y te,t R. u ts PA :? Fo, b.droom
Fluid depth in absorption field before test (in,); ~ _
Fluid depth ! (ins) Minutes later: [O!
Peroxide treatment (past 12 months) (Y/N)
Immediately after,-~-"C'"~gal, water added (in.):
Absorption rate = t"'~/dXZ'_;, _g.p.d.
If yes, give date
72-026 (Rev. 3/96)*
~.~_~_..~. CT&E Environmental Services Inc.
CT&E Ref.#
Client Name
Project Name/#
Client Smnple ID
Matrix
Ordered By
PWSID
Sample Remarks:
985024001
Schindler, Ted
Lt 6 Adn Highlm~d Terrace
Well Outlet
Drinking Water
Client PO#
Printed Date/Time 09/09/98 09:23
Collected Date/Time 09/04/98 10:00
Received Date/Time 09/04/98 11:00
Technical Director: Stephen C. Ede
Released By~~,~.~ ~
Parameter
Results PQL Units Method
Allowable Prep Analysis
Limits Date Date Init
Nitrate-N 0.737 0.100 mg/L EPA 300.0 10 max 09/04/98 09/04/98 GCP
Total Coliform 0 co[/lOOmL SN18 9222B 09/04/98 KAP
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
GENERAL INFORMATION
(a)
(b)
(c)
Application Date
Legal Description (include lot, block, subdivision, section, township, range)
Location (address or directions)
19544- Cl'c.u~
Appl!cant Name_ l~'~e,'~, ~ 'Y/,Vq~,,;~ ~'~:~' Telephone: Home ro~Pq- -~.'S~- Business
A~ 21icant Address
Applicant is (check one): Lending Institution []; Owner/builder [~; Buyer []; Other [] (explain); __
(d) Lending Institution Telephone
:'"Address
(e) Real Estate Company and Agent
Address
Telephone
(f) Mail the HAA to the following address:
TYPE OF RESIDENCE
Single-Family 13t Multi-Family []
Number of Bedrooms "~
Other
WATER SUPPLY
Individual Well ~ Community [] Public [] ,,
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SFWAGE DISPOSAL
Onsite 1~ Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status,
Page 1 of 2 ~-o~5 m.84)
ENGINEERING FIRM PROVIDIE .NSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
AS certified by 'my sear affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the ~umber of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, ~nd regulations in effect on
the date of this inspection.
Name of Firm ~'~c-~_ ~,~ )~ Telephone
Address ~l ~ ~ ~ ~~
Date ~ t~,
Approved ,o, '-~i.~bedrooms by
Approved ~/'~ DisapproveoV/ Conditional .(~.J
Terms of Conditional Approval
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 (11/84)
A. WELL DATA
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
Legal Description:
/~UNICIPALITY OF ANCHORAGE
DEPT. OF HEAl. TH &
/NVI~ONMEN/'AI. PROTEcTIoN
SEP '.l ? I[ [i
RECEIVED
L-co O~O~'~e~,~ T~,~,-~o~ g5
5-7 -F ~4~ Rx~
Well Classification
Well Log P~esent (Y/N)
Total ~pth . ~n~n(z 7 Z~ Card t v~
Static Water ~vel ~ ~t At
Casing Height A~ve Ground
Electrical Wiring in Conduit (Y/N)
Sep~ation Distan~s f~ ~11:
If A, B, or C, D.E.C. Approved(Y/N)
Date Completed ~F~o× /~8 Yield
._ Depth of Grouting.
Sanitazy Seal on Casing (Y/N) Y
Depression Around Wellhead (Y/N) nj
To Septic/Holding Tank on Lot ~' ; On Adjoining Lots lco'~
..
To Nearest Edge of Absorption Field on Lots~ ~Lu~¢~; On Adjoining Lots ~
To Nearest Public Sewer Line 5o'+ To Nearest Public Sewer
Cleanout/Manhole ~o'+ To Nearest Sever Service Line on Lot
Wate~ Sa~ple Collected By Co~.~s~¥u~, .~--~ ~_; Date
Water Sant01e Test Results
~te Installed I~ Size 1~o ~ No. of C~[~nts I
Standpi~s (Y~) ~ Ai~-tight Caps (Y~) ~[ Foundation Cleanou% (Y~)
~p~ession oveF Ta~ (Y~) ~ Date ~st P~d ~
P~i~g/Maintenan~ Contract on File (Y~) Nh ; for
Holding Tank High-Water Ala~ (Y~) ~ Tem~rary Holding Tank Permit (Y~)
Separation Distan~s ~ ~ptic~olding Tank:
To Water-Supply ~11 G~' ~,h~%k~8 To ~ilding Foundation
To ~o~rty Li~ ,o' To Dis~sal Field
To Water Main/Servi~ Li~ ~'+ To S~e~ Pond, ~e, ~ Major ~aina~
Cour~ N h '
[Page 1 of 2]
Receipt 9
Date :Paid:
Amount:
2-15-84
/
C. ABSORPTION FIELD DATA
Soils t~ating in Absorption Strata
Date Installed
Width of Field Il'
Square Feet of Absorption A~ea ~5~'
Depression over Field (Y/N) ~q
/~o~ Type of System Design
Length of Field %~'
Depth of Field ~'
Gravel Bed Thickness ~'
Standpipes ~esent (Y~)
~te of ~st A~qua~ Test 5~+
Results of Last Adequacy Test .~e~ Z~?~u~ ~_~
Separation Distan~ from~sorption Field:
To Water-Supply ~11 ~'+ To ~o~rty Li~ ~ p~~.
To Building Foundation ~'~ To Existing or ~ndo~d System
Lot 7~' ; ~ Adjoining Lots
To Water Main/~rvi~ Line t~'+ To Cutba~(if pre~nt)
To St~e~ond~ke/~ Ma3o~ ~ainage Co~se
To~iveway, Parking ~ea, or Vehicle Storage ~ea
Counts ~ ~9~~ 13~V- ~~
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes(Y/N)
Dimensions
Manhole/Access (Y/N)
~ y "Pump Off" Level at
,r Vent (Y/N)
Pumping Cycles during Adequacy Test.
Meets MOA
Conments
** Check Permitted Bedroc~ Rating Against HAARequest **
I certify that I have checked, verified, or conformed to all MOA HAA
on the date of this inspection.
Signed
Company
KB1/d5/s
[Page 2 of 2]~g/z~~ ~'~,C,a~}
Date 9-~ ~-~55
MOA No.
in effect
2-15-84
DEPARIME]
825
MUNICIPALITY OF ANCHORAGE C~o~
OF ttEALTH ~ND ENVIRONMEN PROTECTION
L Street, Anchorage, Alaska -9950].
279-2511, ext. 224 or 225
Date Received: April 22, 1977
#1: Time 10:30 a.m. #2: Time #3: Time
Date 4-25-77 Monday
Date Date
Insp Pratt In~p Insp
REQUEST_ FOR APPROVAL OF INDIVIDUAL SEWER' 4. AND WATER FACILITIES
Lending Institution Request: Alaska Bank of Commerce
Mailing Address: Pouch 7-012 99510 Phone: 279-5641
2. Property Owner: Paul/Carol Jones Phone: 694-2124
Mailing Address:
3. Lega[L Description: Lot 6 Highland Terrace Subdivision #5
4: Single Family Residence: ( ~
Multiple Family Residence:
Number of Bedrooms:
Number of Bedrooms:
Well System:
Permit #
Construction
Public/Community System: ( ) Individual Well: ~ )
Depth of Well Well Log on File (
Bacterial Analysis
Sewage Disposal System: On-site System (xJ Public Utility ( )
PermJ_t # ~/~/~ Insl~alled 1968 .(_?_)___ Installe,? A~ f~/~nm~s.
Septic Tank Size __/_~)~ Fo~_~j~fO~q_~ Manufacturer
Absorption Area ._~1~ ........ Soil. s Rate __.~=~ .... Material
7. Distances: Well to Septic Tank
to Sewer Line Nearest Lot line
to Nearest Lot Line
to Absorption Area 3_ZbZ]'~
Absorption Area
MUNICIPALITY OF ANCHORAGE \x)
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
2510 East Tudor Road, Anchorage, Alaska 99504 43a-C~J~,4.UL.~:r~A;~+¥ ~'J~:/.>k/ ;;:
D;JPI, ~', ,
REQUEST FOR APPROVAL OF :i ,.,.,~;,,~i,,~.~r, ,~.. ..... . , 'HCI,~
INDIVIDUAL SEWER and WATER FACILITIES
1. Type of Inspection:
2. Property Owner,_
Mailing Address:
3. Name of Buyer:__ k'~.C2
Mailing Address:_
VA____FHA
Day Phone:_¢
,- ~7t~ /A'~'DayPhon,:
Name of Lending Institution:, ~ X~¢'
Mailing Address:_ Phone:
Name of Real'tor or Agent: ¢_. <4_ ~.. ~:-;,~ ¢~',..../ { ~¢ O..~:-L~_
Mailing Address: /, (~' ,~ <~,~X ~ ~ X / ' '
Legal Description:
Location:
7. Type of Facility to be Inspected:
8. Water Supply
Type of Supply:
c/
Public Utility Individual
If Individual, number of dwellings presently served
If Individual, depth of well ~/ ~)
9. Sewage Disposal System
Type of System: Public Utility
If Individual, date of installation
Individual (on-site)
!
72 003(3/76)
Page Two
· Department of He~l%h and Environmental Protection
Request for Approval of Individual Sewer and Water Facilities
Legal Description: Lot 6 Highland Terrace Subdivision #5
Co~hme~ts:
Affadavit Attached:~' )
Letter A%tached: (
Disapproved:
Date:
Departmen% Workshee%:
1977
Alaska Bank of Com~t~rce
Mortgage Loan Section
Pouch 7- 012
Anchorage, Alaska 99510
SFbject~ Lot 6 Highland ?efface Subdivision ~5
Before this department will give an ap)?roval on the subject
property, s~ve~al discrepancies must be corrected:
(a) The seepaqe pit must be one-hundred (100) fee'[: from
the well.
(b} '/'he septic tank must be uncov~red, an~[ pump(~;d to
v~rify its size and existanc~.
(o) The well seal must be tightened so that it is
air tight ~
If there are any further questions, pluas~ contact this
office at 279-~2511, extension 224 or 225.
~)bert Co Pratt, ~oS.
Sanitarian