Loading...
HomeMy WebLinkAboutHIDDEN HILLS BLK 1 LT 10Onsite File Hidden Hills Block 1 Lot 10 #011-121-35 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP241065 PID Number: 011-121-35 Dwelling: Fill] Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: X New ❑ Upgrade Name Brent Aafedt ABSORPTION FIELD [:1 Deep Trench El Wide Trench 9Bed El Mound Site Address 6301 Quiet Circle ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 5 1 GPD/SF 10.0 / 7.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 9.4/6.4 Ft. Gravel depth beneath pipe 0.6 / 0.6 Ft. Subdivision Block Lot Hidden Hills 1 10 Fill added above original grade -0.1 /0.9 Ft. Gravel length 32.5 - 55.2 Ft. Township Range Section Gravel width 25 Ft. Beds: Number of Lines 5 Distance between lines 5.0 Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches N/A Dist. between trenches N/A From Tank Field Tank Line 1072 Ft, Ft. Well >100' >1 00' N/A N/A >25' TANK ❑� Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer Capacity 1500 Gal. Surface Water >100' >100' N/A N/A Material Plastic Number of compartments 2 Lot Line >5' 1.0'* N/A N/A NA Foundation > 10' 3.8'* N/A N/A LIFT STATION Ma rer Capacity Gal. Remarks *OSV241014. Deep burial tank. Field info listed as high side / low side. Alarm location installed by PIPE MATERIAL House to tank D3034Tank to D3034 drainfield Installer Red Dog Masonry Drainfield D3034 CO/MTD3034 Inspector J. Opheim & M. Jakubisin BENCH MARK (Assumed elevation) 100 ft Inspection 15, 5/3/24 8/22/24 Location and description dates: 2 r m (h Concrete Slab (See Plan) 3 4 ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date ... i4Cq�,�i + Ale 49 TH . ................. �Ij. �• Benjamin Schiller12592 Septic Syster Approved / Date v1lF�PROFESSIONA f� h�F CE 12/18/24 ,Gal dte: this approval does not include well permit requirements. (Rev 05/02/1)' ALTERNATE SITE: CAT III ADVANCED TREATMENT w/ PUMP VAULT 20' x 5' x 4' ED IF USED, EXCAVATE BED 8' AROUND AND REPLACE WITH IN-SITU SOILS TO ACHIEVE SEPARATION Benjamin Schiller CE 12592R E GISTEREDPROFES S I O N A L E N GINEER 1"=20' 1072 SF ABSORPTION BED CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 2CO PERMIT # OSP241065 PID # 011-121-35 HIDDEN HILLS, BLOCK 1 LOT 10 AB C FEET 0 20 40 FCO 5-BDRM HOME PLAN AS-BUILT 12/18/24 10' UTILITY EASEMENT LU C Y S T QUIET CIR CARPORT MT4 1500-GAL SEPTIC TANK EXISTING WELL MT3 TH#1 MT1 MT2 25.0 55.2 32.5 TH#2 CO6 CO7 CO8 CO9 CO4CO3CO2CO1 CO5 CO10 A B FCO 30.0 MH 40.1 SV 44.3 C 2CO 47.1 MT1 50.1 CO1 50.9 CO2 55.6 10.3 16.2 16.6 17.3 65.3 64.2 CO3 60.3 CO4 65.0 CO5 69.5 MT2 72.3 MT3 CO6 CO7 31.6 8.4 9.8 16.3 CO8 CO9 CO10 28.8 28.3 29.2 MT4 30.5 23.7 30.2 37.0 39.9 64.6 65.9 67.1 68.2 70.5 34.6 34.7 MH SV BM PROFILE AS-BUILT (NO SCALE) 92.8 87.0 93.4 101.4 FC O MH SV PERMIT # OSP241065 PID # 011-121-35 HIDDEN HILLS, BLOCK 1 LOT 10 1500 GAL SEPTIC TANK 101.4 FINISH GRADE ON HIGH SIDE LENGTH VARIES (SEE PLAN) DRAINFIELD ROCK MT 1 TH # 2 NO GROUNDWATER 5/13/24 92.2 CO 1 CO 1 0 80.0 92.2 101.5 ORIGINAL GRADE ON HIGH SIDE MT 4 2C O 92.7 Benjamin Schiller CE 12592 R E GISTEREDPROFE S S I O N A L E N GINEER 12/20/24 99.4 FINISH GRADE ON LOW SIDE 98.5 ORIGINAL GRADE ON LOW SIDE MOA APPROVED SAND 89.589.5 91.591.5 FLOW LINE 92.2 BOT ROCK 91.5 BOT SAND 89.5 BOT FOOTING 92.2 FINAL GRADE 101.4 FLOW LINE @ TANK 92.7 CONCRETE PAD 100.0 3.7' 0.7' BOT TANK 87.0 FINAL GRADE 99.4 - 101.4 FEET 0 2 4 12/31/24 Benjamin Schiller CE 12592 R E G ISTEREDPROFE S S I O N A L E N GINEER 1"=2' PERMIT # OSP241065 PID # 011-121-35 HIDDEN HILLS, BLOCK 1 LOT 10 FOUNDATION TO BED WAIVER PROFILE I N F L U E N C E L I N E 1 1 BED TO FOUNDATION BED TO TANK FILL NOT TO SCALE unlclallty ®f Anchorage �_ i)rparr,,,t•,r P.O. Box 196650 0 4700 Elmore Road Anchorage Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program * * VARIANCE/WAIVER REVIEW Waiver#: OSV241014 COSA#: Permit#:OSP241065 �(4 PID#: 011-121-35 p Legal Description: HIDDEN HILLS BLK 1 LT 10 �pI I �, T n k -f-o i s i'\ 0, 7 Engineer: Forqe engineering^ f Rd -+V �ounda�co n i 35 ' Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 1.0 foot. In addition, the trenches do not follow the contours but are allowed if installed per engineers design. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: �11 2 Approved by: Name of Revievy **** VARIAN C E/WAIVER REVIEW **** December 31, 2024 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Hidden Hills Block 1 Lot 10 – 6301 Quiet Cir Septic system design and waiver requests Dear On-Site Services Engineer: At the time of permitting, we had requested a waiver for a 2’ separation from the tank to the septic field. During installation, however, the actual distance ended up closer to 0.7’. We have discussed with the contractor and the same justifications apply to this lesser separation. The effluent will not degrade the plastic tank. The primary treatment is the 2' sand filter, and even in fast-draining gravel the effluent is assumed to flow vertically through it. As gravel is mostly incompressible and minimally affected by liquid flow there is little risk of either preventing treatment or undermining the tank with effluent from the sand filter. This did not cause a difficulty for construction. For all of these reasons we request a reduced waiver for 0.7’ from the field to the septic tank. Sincerely, Benjamin Schiller, PE MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: _______________ Date of Issue: ____-____-____ Parcel Identification Number: ____-____-____ Legal Description Block Lot Property Owner Name & Address: Pump Installation Date: _____-_____-_____ Pump Intake Depth Below Top of Well Casing: __________ feet Pump Manufacturer’s Name: ___________________________ Pump Model: _____________________________________ Pump Size: ____________hp Pitless Adapter Burial Depth: _________ feet Pitless Adapter Manufacturer’s Name: _________________________ Pitless Adapter Installer: ____________________________ Well Disinfected Upon Completion? XX Yes No Method of Disinfection: _____________________________ Comments: Pump Installer Name: __________________________________ Company: ___________________________________________ Mailing Address: ______________________________________ City: ___________________ State: __________Zip: _________ Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road i. Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 �r hftp://www.muni.org/onsite L)eparct�lc-�tt On -Site Wastewater Disposal System Permit Permit Number: OSP241065 Effective Date: 5/1/2024 Work Type: Septic Initial Expiration Date: 5/1/2025 Tax Code Number: 01112135000 Site Legal Address: HIDDEN HILLS BLK 1 LT 10 G:2222 Site Mailing Address: 6301 QUIET CIR, Anchorage Owner: AAFEDT BRENT & ALEXXANDRA M Lot Size in Sq Ft: 10120 Design Engineer: FORGE ENGINEERING Total Bedrooms: 5 This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: • A LNO from ROW for the well in the Utility Easement is required prior to IR approval. a dJO eVklfl4 tf r"9 to be Ivy -Ae bo -H -o,,, &7 4k, beA. Re e -Received-By: � s � �t � � -to �orc► Issued By: rif% o� ue- �U 15,o 115 �/z�/Zy Date: Date: Z _ Municipality of Anchorage __,. Urp:rtmenr P.O. Box 196650 ® 4700 Elmore Road Anchoraqe, Alaska 99519-6650 0 (907) 343-7904 Fax (907) 343-7997 http://www.muni.org/Onsite Services ii i On -Site Water and Wastewater Program * x * * VARIANCE/WAIVER REVIEW x Waiver#: OSV241014 COSA#: Permit#:OSP241065 PID#:011-121-35/�� S��(I . f'I o a�o�� • Legal Description: HIDDEN HILLS BLK 1 LT 10 , r4,) k z Engineer: Forge engineering y(d Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 1.0 foot. In addition, the trenches do not follow the contours but are allowed if installed per engineers design. This waiver approval applies to the proposed absorption field only. Any fixture upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. ............................................... ■ ............................ 0 ■ i Waiver is Granted: X Waiver is not Granted: Date: � Approved by: Name of Revie **** VARUANCEMAIVERh REVIEW**** MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWERA/VELL`PERMIT APPLICATION Parcel I.D. 011-121-35 Property owner(s) Aafedt Brent & Alexxandra M pay phone Mailing address 2835 Lily St, Anchorage, AK 99517 Site address 6301 Quiet Cir, Anchorage, AK 99502 Legal description (Sub'd., Block & Lot) Hidden Hills Block 1 Lot 10 Legal description (Township, Range & Section) Lot Size 15,120 sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field r_X� Initial FX] Single Family (SF) (wlwo ADU) Septic Tank FX]Upgrade ❑ :Duplex (D) Holding Tank ❑ Renewal ❑ Multiple Dwellings Privy (SF and/or D) Private Well Water Storage ❑ THIS APPLICATION INCLUDES A'VARIANCE / WAIVER REQUEST FOR: Tank/Absorption trench to property line Distance: 91 / 11 I certify that the above information is correct. I further certify that this is in accordance with applicableMunicipal Codes. (Signature ,of property owner or authorized agent) Permit/Rush Fees: Waiver Fees: Z Date of Payment: Date of Payment: Receipt Number: Receipt Number: Permit No. 05P `7 ' Waiver No. 0--' - Permit App_'-'-:- ,'_:c, Jame 18, 2024 UTE E E R I N G Municipality of Mdlor On-site Water and Wastewater REVIEWED FOR CODE COMPUANCE 0--X241001, Deb tM cken(uss, 0&211, PO BOX 240773 (-o ANCHORAGE. AK 99524 ��((// 522-7773 677-7766 (FAX) FORGECIVIL.COM MOA Development Services, On -Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Hidden Hills Block 1 Lot 10 — 6301 Quiet Cir Septic system design and waiver requests Dear On -Site Services Engineer: The owner of the above lot intends to build a 5 -bedroom home on the property, so we are submitting this permit application for the construction of a new septic system. The attached site plan identifies the location of the home as well as the existing well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes moderately to the east at between 5-10% in general. There are some areas that are steeper but do not approach 25%. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new bed will be constructed over the lower gravel layer and will be flat. The soils on this lot support a deep -bury shallow bed, as there is very rocky gravel about 10' below grade, as measured from original grade on the high end (toward the center of the lot). The lot slopes down toward the east, where the gravel is about 7.5' below grade along the property line. However, with the limited area and the location of the existing well the system will only fit if the separation distances to the building, lot lines and septic tank are reduced. The lot lines are the boundaries for the ROW in Quiet Circle and Lucy Street. The installation of bed will not cause problems for the ROW, and will not affect any neighboring lots. Currently, the excavation has been open for the construction of the foundation and installation of the septic tank for well over four weeks, and there have been no problems with sloughing of the side walls. The rocky bed with the sand filter does not undermine any structures. The attached profiles show the relative elevations of the building foundation, bed, and septic tank, and show the reduced separation distances. The bed is outside the line of influence of the building foundation and there is only a small portion of the sand below that falls within that. As clean filter sand is solid structurally and typically considered non-compactable (as is larger gravel/sewer rock), this does not adversely affect the foundation. The effluent from the bed will disperse fairly rapidly through the sand and larger gravel below, spreading laterally minimally. It could reach the septic tank before flowing further downward but will not degrade the plastic tank. The primary treatment is the 2' sand filter, and even in fast -draining gravel the effluent is assumed to flow vertically through it. As gravel is mostly incompressible and minimally affected by liquid flow there is little risk of either preventing treatment or undennining the tank with effluent from the sand filter. For all of these reasons we request waivers for 1' to both South and East lot lines for the bed, 3.5' to the building foundation, and 2' to the septic tank. Code limits beds to being constructed on slopes less than 10%. In this case, we have verified that the gravel layer that we are installing on is flat below the surface of the ground, and we have test hole information down more than 12' further below with no impermeable layers or groundwater. The bed will be built flat, and we have evidence of much more than sufficient vertical separation even taking into account the approximate 3-4' difference in surface grade from one side to the other. We request a waiver to allow the bed to be built as a deep burial bed on a slope greater than 10%. The bed, as it fits, would be wider than the standard 15'.1 have discussed this with the contractor, and they will be able to construct the bed from both sides of the excavation to a width of 10' without tracking onto the bed. They are able to construct the middle portion, whatever they're not able to reach with the equipment, using workers with shovels. We therefore also request approval to construct the bed as a 25' wide bed, the length changing depending on the well radius. We recognize that this is a non-standard installation; however, we are able to make the design work with these basic waivers. The homeowner understands that in the case of drastic failure it may not be easy to excavate or repair the bed after the home and driveway are built, and in that case, they will be looking at using advanced treatment with the alternate site. Wells on this and adjacent lots are shown. The new system will be a minimum of 100' from all wells and surface water. The alternate site is located more than 16' away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE HIDDEN HILLS, BLOCK 1 LOT 10 Onsite Water and Wastewater REVIEWED FOR CODE COfVPLJANI.E OSX241001, Deb VWckenfuss, 06/2 14 LOTS L_ `FG� �( I I ---- -------------------------------- EXISTING WELL 10' UTILITY EASEMENT t l tc CARPORT 1 1 ALTERNATE SITE: - CAT Ill ADVANCED TREATMENT I w/ PUMP VAULT - 20'x5'x4'ED I LOT 11 LOT 14 I 5-BDRM HOME _ 1 f I APPROX. LOCATION OF EXISTING BM TOP MT' SEEPAGE PIT. TO BE LOCATED, FOUNDATION 100.0 EXCAVATED, AND BACKFILLED WITH ACCEPTING SOIL (NATIVE cd' EXISTING. GRADE 94.2 SOIL FROM EXCAVATION) OR MOA TH#2 Q' CO I _- SAND - C0- . C0 CO 55.6 I FCO I 100. TH#1 OG EL 97.7 1coCo CO CO ' T MT -------------------------------------------- 1500-GAL SEPTIC TANK W/ 20"MANWAY 25.0 MIN 10' TO FOUNDATION EXISTING GRADE 94.7 QUIET CII 1072__ SF_ ABSORPTION BED, MAX SEPARATION BETWEEN LEGS 5', MAX SEPARATION TO EDGE OF BED 3' - � — MT'S TO BE WITHIN V OF CORNERS ENG IH E``E0.I NG kk OF At�`ptt�l .rte • " ,� i*'4sTM^ • *��i SEPTIC PLAN �• �. + . Benjai Schiller .:� 0 20 40 2592 islF .,• 5113!24 ,.•�� , FEET tli`F�pROFESSIO0 1"=20' - DEPTH OF EXCAVATION TO GRAVEL LAYER: 7.5' i LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE 7' Cil Or�-site ORC� tewterHIDDEN HILLS, BLOCK 1 LOT 10 REWEVVEDONPUAl OSX241001, Deb Kbckenftas, 06 DESIGN FACTORS: SYSTEM REQUIREMENTS: C-o'-gj 750 GPD PEAK FLOW SHALLOW BED SYSTEM W/ SAND FILTER PERK RATE: <1 MIN/IN 1500 -GAL SEPTIC TANK APPLICATION RATE: 0.7 GPD/SF 750 GPD / 0.7 GPD/SF = 1071 SF BED REQUIRED (1072 SF SPECIFIED) WIDTH: 25', LENGTH CHANGES ALONG WELL RADIUS BOTTOM OF BED: 8' BELOW OG(MEASURED FROM THE HIGHEST OG ELEVATION) BOTTOM OF SAND: 10' BELOW OG (TOP OF GRAVEL LAYER) FLOW LINE ELEVATION: 7.5' BELOW OG NOTE: GRADE HAS BEEN CUT DOWN SIGNIFICANTLY FOR FOUNDATION CONSTRUCTION. MAX DEPTH NEAR PROPERTLY LINES IS 7.5' OG AT WEST END OF FIELD 100.0 PROVIDE ADDITIONAL FILL TO (AT TH#11) ACCOUNT FOR SETTLEMENT -4"' PERFORATED PVC (HOLES DOWN) FLOW LINE 92.5 BOT ROCK 92.0 BOT SAND 90.0 01 A 'k •A *F49 M .......... ....... Benja in Schiller CE 12592 6/13124 HIDDEN HILLS, BLOCK 1 LOT 10 E N Gk"-� I�-- FLOW LINE 89.9 BOT ROCK 89.4 BOT SAND 87.4 On-site Water and Wastewater REVIEWED FOR CODE COlVPUA OSX241001, Deb Mckedun R EXISTING GRADE @ TH1 97.7 FLOW LINE @ TANK 90.0 2' BED SEPARATION PROFILES SCALE 1" = 2' 0 2 4 FEET E OF P'�q���1 � :f 1 *:Q TH ••tt • • • • .. • ' • Benja 'n Schiller ' CE 12592��� �il'j • • , 6113{24 •(� lill:� pROFESS10Na��., �� SOILS LOG AND PERCOLATION TEST E N G I N E E R I N G LEGAL DESCRIPTION: HIDDEN HILLS BLOCK I LOT 10 PERFORMED FOR: BRYAN AAFEDT DATE: 1121121 PARCEL ID#: 011-121-35 DEPTHTEST HOLE 1 ((eel) G 1 1 1 1 1 1 mKol 3 aPERC TEST LOCATION SM (SILTY SAND) SP (SAND / COBBLES) NO WAS WATER ENCOUNTERED'? - IF YES @ WHAT DEPTH? DRY DEPTH TO WATER AFTER MONITORING 1/28/21 DATE OF MONITORING DATE READING START TIME NET TIME DEPTH To WATER NET DROP (MINUTES) (INCHES) INCHES) 1/21/21 1 1:02 9:21 10 716 6 16 2 1:12 10:00 1 0 516 416 3H1:23 10:00 1 16 416 3 16435 10:00 116 4 a 3 1°-6 5 1:47 10:00 1 4 3 16 16 16 6 1:50 10:00 1-1 3 is 2 16 PERCOLATION RATE: 3.4 (MIN/INCH) COMMENTS: USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED SITE PLAN TECHNICIAN: L. TIDWELL DEPTH (feet) 1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1 1 2 2I.J E E N G i N E E g i N G Co 70f I 1. SOILS LOG AND PERCOLATION TEST LEGAL DESCRIPTION: HIDDEN HILLS BLOCK I LOT 10 PERFORMED FOR: RED DOG MASONRY DATE: 5/6/2024 PARCEL ID#: 011-121-35 TEST HOLE LOT HEAVILY GRADED. RELATIVE ELEVATIONS CONFIRMED WITH LASER SM (SILT WITH SAND) aPERC TEST LOCATION GP (POORLY -GRADED GRAVEL W/ SAND) NO WAS WATER ENCOUNTERED? IF YES �( WHAT DEPTH? NONE DEPTH TO WATER AFTER MONITORING 5/13/202Z' DATE OF MONITORING DATE READING START TIME NET TIME (MINUTES) DEPTH To WATER NET DROP INCHES) (INCHES) 5/6 1 3:00 0:07 1 0 7 0 616 2 3:00 0:09 1 0 7 0 616 3 3:00 0:10 1 16 716 616 4 3:01 0:13 1 16 7 16 6 16 5 3:01 0:14 1 16 716 616 6 3:01 0:16 1 16 716 616 PERCOLATION RATE: 0.04 (MINANCH) SITE PLAN TECHNICIAN: J.OPHEIM COMMENTS: USCS SOIL CLASSIFICATION OF GP DETERMINED BY LABORATORY ANALYSIS oGRE"- R ANCHORAGE AREA BOF"'JGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION SEPTIC TANK: DISTANCE / FROM WELL INSIDE LENGTH MANUFACTURER ('~-Jl')--f;~ ..... ¢: I)~' MATERIAL ~ -- - '-- INSIDE WIDTH ..... LIQUID DEPTH - - NUMBER OF COMPARTMENTS LIQUID CAPACITY i~}C) O GALLONS. SEEPAGE PIT: NUMBER OF PITS I DIAMETER OR WIDTH i:z) '~ / --- ~ LENGTH t~, DEPTH l"~:~ ' LINING MATERIAL J._--0~%l CRIB SIZE: DIAME-TER____DEPTH ~_'/ DISTANCE FROM: WELL BUILDING FOUNDATION ~C~-~ / NEAREST LOT LINE '~-,~]) / TOTAL EFFECTIVE .... ABSORPTION AREA (WALL AREA) '~ [ SQ. FT. ADDITIONAL ABSORPTION TYPE (:P BUILDING FOUNDATION C ESSPOO L APPROVED _CONSTRUCTION NEAREST LOT LINE OTHER SOURCES DISAPPROVED NEAREST SEWER LINE REMARKS DEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK. SYSTEM INSTALLED BY: =b PIPE MATERIAL: LOT SLOPE: Form No, EQ-031 DIAGRAM OF SYSTEM GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL (~UAI. ITY 3330 "C" STREET ANCHORAGE, ALASI'(A 99503 TELEPHONE 274-4§61 PERMIT NO, SEWAGE DISPOSAL SYSTEM --- APPLICATION AND PERMIT FINANCED THROUGH TO BE INSTALLED SY'~¢ O6¢ )/~ ~ _. NOTE: THI¢ PERMIT IS ~40'f VAI,,ID ~¢ITHOUT SOlE TEST COMPI_ETION DATE ANTICIPATED ~/~ / WELt. TO SEPTIC TANK (//~ j SEEPAGE PIT /'~00 WATER MA,N TO ~EPTIC TANK_ /'0 ., SEERAGE P~T / :~ 'rG RIVER. LAKE, STREAM TYPE CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION, CERTIFY 'rFIAT I AM FAMILIAR WFFH THE REQUIREMENTS OF GREATER-~NCHORAGE A~ BOROUGH ORDINANCE DESCRIBED SYfiTEM I$ IN ACCORDANCE WITH $AID CODE,,./ . / ~/, ¢"%/h/- /. / ~ THAT THE ASOVE BILL SHEFFIELD, GOVERNOR DEPT. OF ENVIRONMENTAL CONSERVATION Telephone: (.o07) 274-2533 Address: 437 E. Street Suite 200 Anchorage, AK 99501 October 5, 1983 Mr. Leroy C. Reid, P.E. Alaska Environmental Control Services, Inc. 1200 W. 33rd Avenue, Suite B Anchorage, Alaska 99503 Dear Mr. Reid: MUNICDIEPALITy OF Ai~.C . -PT O[ ~ ' FIORAo.c ENV Ro~,,,,i~,.' ,.'Z/.LTH ~: "~ 'zr',!TAL pROTECFiON RECEIVED Subject: Lot 10, Block 1, Hidden Hills Subdivision The Department has reviewed the request for a waiver of the 150 feet well to septic separation distance on the subject property and cannot grant the waiver because the small Lot sizes of Lots 8, 9, 10 and 11 increases the risks of contamination for these wells which have no impervious layer between the source of contamination and the water table. Sincerely, Environmental Engineer BEE/msm cc: Robbi Robinson, MOA "One test is ~vorth a thousand opinion, s" ~62~ TUDOR ROADi ANCHORAGE, ALASKA ~g~O7 · TELEPHONE 333-8472 Performed For '3--t~ ~~ b~ Date Performed~-¢-7~ Legal ~escrintion: Lot./~__Block "~ Subdivision This Form Re~orts Soils LoQ ~_ Percolation Test nenth Feet Soil Characteristics 1 5 7-- in /s ' ,I ~as 6round ~ater Encountered? I~ Yes, At what Depth? Percolation Rate Minute Proposed Installation: SeeDaae Pit Drain Field Den. th of Inlet DePth To Bottom Of Pit Or Trench Test Performed By_ :~ m~:K Data Certified Net Drop Readin~ Date Gross Time Net Time Depth to 1 H20 STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING, LAND & WATER Alaska Hydrologic Survey WATER WELL LOG Revised 08/18/2016 Drilling Started: ____/____/______ Completed: ____/____/_______ Pump Install: ____/____/_______ City/Borough Subdivision Block Lot Property Owner Name & Address Well location: Latitude Longitude Meridian ____________ Township ______ Range _______ Section _______ , _____ 1/4 of _____ 1/4 of _____ 1/4 of _____ 1/4 BOREHOLE DATA: (from ground surface) Suggest T.M. Hanna’s hydrogeologic classification system* https://my.ngwa.org/NC__Product?id=a185000000BYub3AAD Depth From To Drilling method:  Air rotary,  Cable tool,  Other Well use:  Public supply,  Domestic,  Reinjection,  Hydrofracking  Commercial,  Observation/Monitoring,  Test/Exploratory,  Cooling,  Irrigation/Agriculture,  Grounding,  Recharge/Aquifer Storage,  Heating,  Geothermal Exploration,  Other Fluids used: Depth of hole: __________ ft Casing stickup: ___________ft Casing type: __________ Casing thickness: _________ inches Casing diameter: _________ inches Casing depth: __________ ft Liner type: _________ Depth: _____ ft Diameter: _____inches Note: Well intake opening type:  Open end,  Open hole, Other Screen type: _________, Screen mesh size: ____________ Screen start: ________ ft, Screen stop:________ ft, Perforated  Yes  No Perforation description: Perf from: ________ ft, Perf to: _______ft, Perf from: ________ ft, Perf to: ________ ft Gravel packed  Yes  No Gravel start: ______ ft , Gravel stop:______ ft Note: Static water (from top of casing): _______ ft on____/____/_____ Artesian well  Pumping level & yield: ______ feet after _____ hours at _____ gpm Method of testing:__________________________________________ Development method:______________ Duration: ____________ Recovery rate: _________ gpm Grout type: _________________ Volume __________________ Depth: From ___________________ft, To ___________________ft Final pump intake depth: __________ ft Model: _______________ Pump size: _____________ hp Brand name: __________________ Include description or sketch of well location (include road names, buildings, etc.): Was well disinfected upon completion?  Yes  No Method of disinfection: Was water quality tested?  Yes  No Water quality parameters tested: Well driller name: .................................................................................. Company name: ................................................................................... Mailing address: .................................................................................... City: __________________________ State: AK Zip: ___________ Phone number: (________) ________- ______ Driller’s signature: Date: ______/______/_________ Anchorage Municipal Code 15.55.060(I) and North Pole Ordinance 13.32.030(D) require that a copy of this well log be submitted to the Development Services Department/City within 30 days of well completion. City Permit Number: _____________________________ Date of Issue: _____/____/_________ Parcel Identification Number: ______-_______-________ *Guide for Using the Hydrogeologic Classification System for Logging Water Well Boreholes by Thomas M. Hanna NGWA Press AS 41.08.020(b)(4) and AAC 11 AAC 93.140(a) require that a copy of the well log be submitted to the Department of Natural Resources within 45 days of well completion. Well logs may be submitted using the online well log reporting system available at: https://dnr.alaska.gov/welts/ OR email electronic well logs to dnr.water.reports@alaska.gov North sandy gravel - possibly silty n110 gravelly sand S 1973 12 105 94 JAMES LAUGHLIN , n 12 L10 9 silty sand NW n 39 137 110 HIDDEN HILLS 1 89 n 18 0 138 012N n gravelly, silty sand 004W clayey sandy gravel 94 105 39 sandy clay gravelly sand NE 18 5 Municipality of Anchorage ARCTIC DRILLING (ANCHORAGE) B1 14180 89 gravelly sandy clay - dark brown men t. PV1IN1` R CffPALITY OF A` C H[O AGE N,°� Devellopmenit Servkes Department q 4w, Dight ®i Way Sectionopalt ENCROACHMENT IENT PERIV[i �T R251079 THIS AGREEMENT, made this 10th day of January 2025, by and between BRENT AAFEDT & ALEXXANDRA M and their heirs, administrators, and assigns, hereinafter called "PERMITfEE", and the Municipality of Anchorage, a municipal corporation organized and existing under its Charter and the laws of the State of Alaska, hereinafter called the "PERMITTER". WITNESSETH: WHEREAS, PERMITTEE is the owner of the following described real property: HIDDEN HILLS SUBDIVISION, BLOCK 1, LOT 10, according to the official records thereof, on file in the office of the District Recorder, Anchorage Recording District, Alaska, and; WHEREAS, PERMITTER owns and/or maintains the real property more particularly described as follows: The TEN FOOT UTILITY EASEMENT, immediately to the north side of PERMITTEES property as shown on Plat No. 70-338, on file in the office of the District Recorder, Anchorage Recording District, Alaska, and; WHEREAS, PERMITTEE has placed a well upon the referenced real property which encroaches 9.0 feet upon the PERMITTER'S 10.0 -foot Utility Easement. NOW, THEREFORE, it is mutually agreed between the parties hereto that: 1. The PERMITTER, acting through the Director of Development Services Department, hereby grants to the PERMITTEE the privilege of allowing well to encroach 9.0 feet upon the PERMITTER'S l 0.0 -foot Utility Easement, as shown on "Attachment A," included herewith. The PERMITTEE agrees forever to indemnify, defend, save and hold harmless, the Municipality, its officers and employees, from any and all lawsuits, claims or actions brought to any person for or on account of damage to property or injury, disease, illness or death of persons, including all costs and expenses incident thereto, arising wholly or in part from or in connection with the existence of, alterations, maintenance, repair, renewal, reconstruction, operation, use or removal of the encroaching well, as placed upon the PERMITTER'S 10.0 -foot Utility Easement. The PERMITTEE shall not assign or transfer any of the rights granted herein to another individual or company without first notifying and securing the approval of the Director of Development Services Department. 4. This Agreement and Permit grants PERMITTEE no interest in PERMITTER'S real property whatsoever, except only the encroachment rights described herein. 5. The PERMITTER reserves the right to revoke this permit upon twenty (20) days written notice to the PERMITTEE. The PERMITTEE agrees upon such notice of revocation, to move said encroachment(s) from the 10.0 -foot Utility Easement in which it is placed. Should the PERMITTEE refuse or fail to comply with said written notice, the PERMITTER may, without further notice to the PERMITTEE, remove or cause to be removed the encroachment(s), and the PERMITTEE hereby agrees to reimburse the PERMITTER for all costs incidental to the removal thereof. In addition to the mutual promises heretofore made, the PERMITTEE has paid the PERMITTER a one-time permit application fee of $120.00. The PERMITTER hereby waives the annual fee of $315.00. IN WITNESS WHEREOF, the parties hereto have hereunto set their hands and seal the day and year first hereinabove written. GRANT Alexxandra M Aafedt Owner Brent Aafedt Owner GRANTOR: MUNICIPALITY OF ANCHORAGE John Snelson Right of Way Supervisor POST IN A CONSPICUOUS PLACE ALL WORK MUST BE INSPECTED Field Inspection Request required 2 working days in advance of starting work and 2 working days in advance for final inspection. Call (907) 343-8206 (voice recorder) for scheduling. Permit is not valid without the call-in and also must include the one -call ticket (utility locate) number. ✓� MUNICIPALITY OF ANCHORAGE - RIGHT OF WAY DIVISION 4700 ELMORE ROAD TELEPHONE (907) 343-8240 EMAIL: moarowrequests@muni.org RIGHT OF WAY PERMIT 1)'_.partIII t'til R251079 Type: Encrchmnt Status: Issued Grid: SW2222 Date Applied: 01/10/2025 Date Issued: 01/10/2025 Issued By: PWMSW Construction Start Date: 01/10/2025 Last Updated: 01/10/2025 Last Updated By: PWMSW Permittee: AAFEDT BRENT & ALEXXANDRA M Work Order: Utility: Contact Person: Ben Schiller, 907-522-7773 Primary Inspector: ROW Lead Address/Loc: 7726 LUCY ST, Anchorage - @ Quiet Legal Description: HIDDEN HILLS BLK 1 LT 10 G:2222 Original Work Encroachment of an existing well 9' into a 10' utility easement. Description: Summarized Financial Transactions Fee Description Quantity Amount Permit 1 $120.00 Total Fees: $120.00 See reverse for requirements/remarks. I have read and understand both sides of this permit. I agree to the terms and conditions; and I certify that all work will comply with federal, state, and municipal codes and regulations and the provisions of this permit. Signature: '`' 9 �i Date: 1-9-2025 ) a Municipality of Anchorage MUNICIPALITYDeveJUN 10 2024 Right lof Way Section Servicesent Department 4700 Elmore Road - Anchorage, AK 99507 APPLICATION FOR RIGHT OF WAY PERMIT p W, Permit Coun�one 907-343-8240 By MOAROWrequests@muni.org PRIMARY SITE i kL Street # - 4-3VI Street Name Quiet Circle Parcel # 011-121-35 Nearest Cross Street Kincaid Road Plat 70-338 Grid SW2222 --- ----- — - _ . -- ------ - - - - - - ---- -- .... -- - Subdivision Name Hidden Hills Block 1 Lot 10 Tract APPLICANT AND CONTACT Permittee Forge Engineering (Ben Schiller) ❑ Contractor ❑ Utility ❑ Owner Mailing Address P.O. Box 2407773 City Anchorage State AK Zip 99524 PROJECT DETAILS Type of Permit ❑ General ❑ Rental ❑ Driveway ❑ Utility ❑ Street Maint. ❑ FN Encroachment MOA" "MOA Project Name Project # Work Order # Utility Acct # Activity Date: From To Description: The well is located Inside the utility easement Onsite has requested we seek an encroachment permitfrom ROW prior to approval of the inspection report. ROAD CLOSURE DETAILS Use Supplement Worksheet for additional closures Road Name ❑ Full ❑ Partial ❑ None Adjacent to TCP Attached? ❑ Yes ❑ No Closure Dates: From T Hours of Closure From 0 To ❑ Sidewalk Only ❑ On its Way A full road closure or a partial road closure on a classified arterial or collector street requires an approved Traffic Control Plan (TCP) signed by MOA Traffic Department. Consult the OS&HP to determine road classification. RIGHT OF WAY DETAILS Check all that apply. Use Supplemental Worksheet for additional rights of way. Location Type Surface Material Road Prism Pavement Age Construction Method Curb & Gutter ❑ MOA Right of Way ❑ Gravel / Dirt (see reverse) ❑ 1 orLessYr ❑ Trench Open ❑ None X Utility Easement(s) ❑ Asphalt ❑ Inside ❑ 1to2Years ❑ Boring/Trenchless ❑ Type 1 ❑ Drainage Easement ❑ RAP/Chip ❑ Outside ❑ 2to3Years ❑ Existing Conduit ❑ Type 2 ❑ Public Use Easement ❑ Concrete ❑ N/A ❑ 3YearsPlus ❑ Aerial ❑ Type 3 ❑ BLM Easement ❑ Grassy Area ❑ No Cut Required ❑ Closure Only ❑ Type 4 ❑ Pedestrian/Bike Trail � developed ❑ Maintenance Only ❑ ❑ Sidewalk ❑ N/A ❑ Alley Lineal Feet Parallel to Right of Way Centerline I certify 1 am the owner/authorized representative for the project described in this Right of Way Permit application and that all work will comply with federal, state and municipal codes, regulations, relevant design criteria and conditions of the permit. 5/6/24 (907) 522-7773 office@forgecivil.com signature Date Phone Email Ben Schiller Printed R.cci'M Mard 2012 (PLEASE PRINT DOUBLE SIDED / FRONT TO BACK) 1'11gc 1 0-2 PARID:01112135000 LUC: 100 AAFEDT BRENT & ALEXXANDRA M 7726 LUCY ST TAX YEAR: 2024 Property Information Property Location: Class: Use Code (LUC): Condo/Unit #: Tax District: Zoning: Plat #: HRA #: Grid #: Deeded Acres: Square Feet: Legal Description: Economic Link: Owner Owner Co -Owner Care Of Address City / State / Zip Deed Book/Page Tax Information Parcel Roll Tax Cycle DID Goss Amount Type Year Tax .00 96.66 -881.00 Amount 01112135000 RP 20241 888.79 01112135000 RP 20242 888.78 01112135000 RP 20231 892.38 01112135000 RP 2023 2 892.38 01112135000 RP 20221 883.26 01112135000 RP 20222 883.26 01112135000 RP 2021 1 1,890.29 01112135000 RP 20201 2,101.59 01112135000 RP 20191 2,018.82 01112135000 RP 20181 2,054.92 01112135000 RP 20171 1,882.33 01112135000 RP 2016 1 1,722.77 Assessed Value 6301 QUIET CIR R - Residential 100 - Residential Vacant Land 03 R5 70-338 SW2222 10,120 HIDDEN HILLS BLK1LT10 No Show Parcel on Map AAFEDT BRENT & ALEXXANDRA M 2835 LILY ST ANCHORAGE, AK 99517 0000 Res Sr/Vet IPC Paid Net Exemption Exemption Billed Amount Due 112.21 -1,001.00 .00 96.66 -881.00 104.44 104.11 -996.49 .00 .00 -892.38 .00 .00 -883.26 .00 .00 -883.26 .00 .00 -1,890.29 .00 251.92 -2,353.51 .00 437.91 -2,456.73 .00 681.85 -2,736.77 .00 993.46 -2,875.79 .00 879.16 -2,601.93 .00 Make a Payment Interest Penalty Costs Total Due Due Due Due Due Date .00 .00 .00 .00 06/30/2024 3.66 .00 .00 108.10 08/31/2024 .00 .00 .00 .00 06/30/2023 .00 .00 .00 .00 08/31/2023 .00 .00 .00 .00 07/31/2022 .00 .00 .00 .00 09/30/2022 .00 .00 .00 .00 06/15/2021 .00 .00 .00 .00 07/15/2020 .00 .00 .00 .00 06/15/2019 .00 .00 .00 .00 06/15/2018 .00 .00 .00 .00 06/15/2017 .00 .00 .00 .00 06/15/2016 Tax Year Roll Type LUC Class Land Building Total Appraised 2024 RP 100 R 110,100 0 110,100 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: (907)343-7904 On -Site Water & Wastewater Section Fax: (907)343-7997 Certificate of On -Site Systems Approval OSC241523 Parcel ID 011 -121-35 Expiration Date: Legal description HIDDEN HILLS BLK 1 LT 10 Site address 7724 LUCY ST. ADU 12/10/2025 Current property owner(s) AAFEDT BRENT & ALEXXANDRA M By: This'Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. The On-site system(s) is/are approved for bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or conditions: ATTACHMENTS: COSA Checklist Absorption Field Advisory Tank Age Advisory Other X Well Flow Advisory Nitrate Advisory Arsenic Advisory M 12-1 v 3 4 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 011-121-35 Complete legal description Hidden Hills, Block 1 Lot 10 Location (site address) 6301 Quiet Circle, Anchorage, AK, 99502 Current property owner(s) Brent & Alexxandra Aafedt Day phone 2. ON-SITE SYSTEMS SIZED FOR 5 BEDROOMS 3. TYPE OF WATER SUPPLY:❑ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ❑■ Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel X Plastic ❑ Concrete ❑ Fiberglass Age NEW - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ■❑ Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Tank to absorption field Distance: 0.79 Expedited review requested: Al By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee Date of Payment12 2 ZPZ`I COSA # S c' t Waiver Fee $ Date of Payment Waiver # COSA Application—June 2022 8.53 N/A N/A N/A Benjamin Schiller, P.E. (907) 522-7773 WELL FLOW TEST REPORT Conducted by Anchorage Well & Pump Service 7640 King Street, Anchorage AK 99518 Ph: (907) 243-0740 Fax: (907) 243-0742 OWNER INFORMATION PUMP INFORMATION Owner: Intake Depth: Address: Static Water Level: Depth of Casing Max Drawdown: None Well Production: PUMP ON Time: 12:58pm Date: 04/03/04 (at time of test) PUMP OFF Time: 2:17pm Date: 04/03/04 Gallons Comments Pumped 04/03/24 12:58pm Start 04/03/24 2:17pm 770.0 Stop 770 gallons in 79 minutes 770 ÷ 79 = 9.75 9.75 gpm 11220 11990 Water LevelElapsed Time Feet Reading 9.75 gpm Flowmeter 134' 99' Gene Aafedt 6301 Quiet Cir Anchorage, AK 99502 * Well chlorinated and flushed prior to test. Test performed at wellhead MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT On -Site Water and Wastewater Section www.muni.org/onsite �i Nitrate Advisory Certificate of On -Site Systems Approval # OSC241523 Subdivision: Hidden Hills, Block: 1, Lot: 10 907-343-7904 Fax: 343-7997 A water sample revealed a nitrate concentration of 8.53 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Since nitrates are known to slowly increase, we recommend you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. N 12/18/2024 Feet 0 30 60