HomeMy WebLinkAboutHIDDEN HILLS BLK 1 LT 18QGRE :'ER ANCHORAGE AREA BO' Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 'UGH INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION (~ (.'[ J.~'J"' LEGAL DESCR,PT,ON ,~r/r a I fl~4U.~ fl,/?,~' SEPTIC TANK: DISTANCE FROM WELL MANUFACTURER MATERIAL ~ ~""'~'~( NUMBER OF COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY. //(')OC') GALLONS, SEEPAGE PIT: NUMBER OF PITS LINING MATERIAL. I BUILDING FOUNDATION_ ADDITIONAL ABSORPTION CRIB SIZE: DIAMETER ~1" DEPTH ~ DISTANCE FROM: WELL /(~ O TOTAL EFFECTIVE , NEAREST LOT LINE l0 . ABSORPTION AREA (WALL AREA) ~(~(' SQ. FT. WELL: BUILDING FOUNDATION CESSPOOL APPROVED _CONSTRUCTION NEAREST NEAREST LOT LINE SEWER LINE OTHER SOURCES DISAPPROVED REMARKS DEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK SYSTEM DISTANCES: INSTAL. LED BY: k~Lu PiPE MATERIAL, LOT SLOPE: REMARKS: Form No, EQ-031 DIAGRAM OF SYSTEM DATE"'~'(~-'''~¢' APPROVED ('LC ~J~AI~' G.A.A.B. GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM B APPLICATION AND PERMIT PERMIT NO. ___ PHONE INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH COMPLETION DATE ANTICIPATED SEEPAGE PIT /X~ , DRAIN FIELD OTHER TO BE INSTALLED BY ~ NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24. HOUR NOTICE REQUIRED, BACKFILLING OI:' ANY SYSTEM WITHOUT FINAl. INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPT,C TANK s,,E MINIMUM DISTANCE~, REOUIREMENTS FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE PIT WALL TG .S*R~ST LOT ~IN~. ("1~)~U¢-~¢' SEEPAGE AREA SIZE TYPE TYPE /:$--4//-~- ?f'/O : WRLL TO SEPT,C TANK /00 DRAIN PlELD WATER MAIN TO SEPTIC TANK DRAIN FIELD DRAIN FIELD ., DRAIN FIELD SEEPAGE PIT ALSO CONSIDER AREA WELLS, · SEEPAGE PIt TO RIVER, LAKE. STI;tEAM. DRAIN FIELD CAST IRON INtO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAV/~T_~ION ~ FEET INTO UNDISTURBED SOIL. ~4~1~C~1 DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION· I CERTIFY THAT I AM FAMILIAR WlTB THE REQUIREMENTS OF HEATEr AN~)l~AgE /~,REa BOR~UGb/~ORDINANCE NO. 28-68 AND THAT TNE ABOVE DESCRIBED SYSTEM '$ IN ACCORDANCE WITH SAID CODE. ~~-'~/ 5/ ~~ ~/l/ soil ~_ The sediments show a low compaction and wate G][ content. The contacts between the soil types are erratic. M1 Sp' Reading .{ Slope is to the S and E Depth To H20 ~~~ _~et ni h~'To _ ~ - ....... ~ c~b .= ~ . ~ ~ D~, ~ RECEIVE[) ~ INSPECTION APPOINTMENTS ~I'1M I: TIME ------ TIM[-' ' iNSPECTOR - INSPECTOR iNSPECTOR ~ MUNICIPALITY OF ANCHO~AGh MUNICIPALITY OF ANCHORAGE Di:P[ OF J::  DEPART~N~ OF HEALTH & ENVIRONMENTAL PRO~E~iF&~Ni~;~j,,d,,, ; 825 L Street - Anchorage, Alaska 99601 ENVIRON~ENTAL~ANITATIONDIVISION .... ~ "' :~;~ Telephone 264-4720 ~ ..... ~ . REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND 8EWER FACILITIES ~IRECTION8: Oomplete ail parts on page 1, Incomplete requests will not be processed, Please allow ten (10} days for procesGing, 1. PROPERTY OWNER - MAI LING ADDRESS ~ ~ ~8~~t from abo~) ~ ~ ..... ~NE MAILING ADDRESS ~ ~ n -- ~ ' 5, LEGAL DESCRIPTION 6. TYPE OF RESIDENCE [~ SINGLE FAMILY [] MULTIPLE FAMILY NUMBER OF BEDROOM8 [~ One ~l Four [] Other ~I~ Two --] Five [] Three --] Six 7, WATER SUPPLY INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG. A well Icg is required for all wells drill~-d since June 1975. For wells drilled prior to that date, give well depth (attach Icg if available,) 8, SEWAGE DISPOSAL SYSTEM [] NDIVIDUAL/ON-SITE*~ [] PUBLIC UTILITY YEAR oN-SITE SYSTEM WAS INSTALLED. EMOTE: THE INSP,.ECTIOI~ FlEE MUS,T ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 'Rev. e/79) / THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [~SI N G LE FAMILY [~ ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY I~ TWO [] FOUR [~] SIX PERMIT NUMBER 2, WATER SUPPLY ~' DEPTH OF WELL INDIVIDUAL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. 'SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [~DIVIDUAL/ON -SITE DATE INSTALLED E~PUBLIC UTILITY Connection Verified ~NSTALLER E~Septic Tank or E~] Holdin9 Tank Size:/~O k~ IfTank ishomemade SOILS RATING give dimensions: TYPE OF TANK ~-~) MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4, DISTANCESwELL TO: Septic/Holding Tack [Absorption Area ]Sewer Line [ Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS . '' PPROVED FOR q/ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED ALASKA i FIUIROFlmeF1TAL COFITROL SE!RUICE!$, IFIC. I~n§in~erir~c1 8 I~nui~'onmcntal StuJ:Jics 9/23/81 LESLIE JORDON 3931 MARQUIS WAY ANCHORAGE AK 99502 SELLER - LESLIE JORDON SUBDIVISION-HIDDEN HILLS SBDN BLOCK-1 LOT-18 ADEQUACY TEST FOR SEWER SYSTEM ~{E TYPE OF ABSORPTION SYST~ IS A PIT WITH AN AREA OF 864 SQFT. THE SYST~t~4 IS (iAPA~SLE OF ACCEPTING 450 GALLONS OF WATER PER DAY. THE SURGE CAPACITY OF THE SYS%~_.~ IS 630 GALIJDNS. BASED UPON THE TEST DA~.~A THE SYSTEM IS ACCEPTABLE FOR A 3 BEDROOM HOME. THE SEPTIC TANK Wk~ PUMPED ON 9/23/81 . SEPTIC TANK ADEQUACY THE EXISTING SEPTIC TANK VOLUME OF THIS 3 BEDROOM HOUSE° 1000 IS ADEQUATE FOR 1220 LUesl 25th J~uenu¢ · J~nchoraq~', /~lr~sk,] 99503 · [907] 276q361 September 24, 1981 Franklin/Leslie Jordan 393]_ Marquis Way Anchorage, Alaska 99502 Subject: Lot 18 Block 1 IIidden Hills Subdiv:.sion Approval for'the individual sewer and water facilities cannot be granted until the following items have been completed: (1) The water analysis report needs to be submitted to this office from the Chem Lab, 5633 1~ Street, for our review. The septic tank pumped with a receipt submit:ted to this office for our review. An adequacy test needs to be performed on the existing leaching area. This test will. determine if the system is adequate according ho National Standards. A listing ,of private firms performing the test is enclosed. This report needs to be submitted te this e~Tfice for our review. If there are any further questions, please ca].l this office at 264-4720. Sincerely, James S. Roberts Associate Environmental Specialist JSR/ljw cc: First National_ Bank of Anchorage Post Office Dox 720 991510