On-Site Wastewater Disposal System Permit
OSPl11000
01112145000
Septic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
January 04, 2011 to January 04, 2012
ANDERSON ENGINEERING
HIDDEN HILLS
HIDDEN HILLS BLK 1 LT 20 G:2222
STUART ELIZABETH
8008 INGRAM ST ANCHORAGE AK 995023998
Site Mailing Address: 6470 QUIET CIR, Anchorage Lot Size in Sq Ft: 20616
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field N Septic Tank
N Holding Tank N Privy N Private Well
N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: CO1 changes the design engineer and makes some minor design revisions.
.-.'- d"~
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Bragaw St.
P.O. Box 196650
Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLIN6
Parcel I.D. 011-121-45
Property owner(s) SCOTT STUART
Day phone 244-8568
Mailing address
6470 QUIET CIRCLE * ANCHORAGE, AK * 99502
Site address 6470 QUIET CIRCLE * ANCHORAGE, AK
Zip Code 99502
Legal description (Sub'd, Block & Lot) HIDDEN HILLS S/D; BLOCK 1, LOT 20
Legal description (Township, Section & Range) N/A
Lot Size Sq. Ft.
Number of Bedrooms
THIS
APPLICATION IS FOR ( [] all that apply):
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
............................
Permit/Rush Fees:
Date of Payment:
Receipt Number:
(Rev. ~ ~/o5)
Waiver Fees:
Date of Payment:
Receipt Number:
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
July 1, 2011
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 20, Block 1, Hidden Hills Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 20, Block 1, Hidden Hills Subdivision intends to construct a new three-
bedroom home on the lot. A mobile home was recently located on the lot and has since
been removed. The mobile home was served by a STEP tank acting as a holding tank.
We are therefore requesting a permit be issued for the construction of a new septic
system to accommodate the new home. The lot is currently served by a Class C Water
System. The attached Site Plan and backup documentation identify the location and
configuration of the proposed septic system along with the alternate site and the
existing STEP tank which will be removed from the site. No existing wells or septic
systems conflict with the proposed septic system. Drainage arrows are shown on the
site plan showing the grade and direction of flow on the lot. The drainage pattern will
not be changed as a result of this project.
The test holes placed on the lot in the area of the absorption trench and alternate site
indicated poorly graded sand and silt (SP/SM). The percolation rate in the material was
determined to be less than 1 to 2 minutes per inch. No groundwater was found during
the placement of the test holes and none was noted during the monitoring period. An
application rate of 1.0 gallons per day per square foot was used in the design of the
absorption system. We are proposing to place a new 1,000-gallon septic tank and a 33'
long by 3' wide by 7' effective depth absorption trench to treat and dispose of the
effluent generated in the house. The elevation of the distribution line in the absorption
trench will be 4' below the surface and the total depth will be 11'. A minimum of 3' of fill
or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the
septic tank.
The ground surface on the lot in the area of the absorption trench is virtually flat with a
Co:!.
Lot 20, Block 1, Hidden Hills Subdivision
July 1, 2011
Page Two
slight grade to the west. A steep slope however is located to the south and east
approximately 30' to 35' from the edge of the new or alternate absorption trench. A
waiver has been issued allowing the trench to be located less than 50' from the edge of
the trench. The new trench will be constructed parallel with the contours of the slope as
much as possible in conformance with Municipal requirements. The new septic system
will be constructed a minimum of 100' from any surface water and 10' from the
proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
o
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
COX'
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
July 15, 2011
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 20, Block 1, Hidden Hills Subdivision
Absorption Trench to Slope Waiver
Dear Onsite Services Engineer:
Lot 20, Block 1, Hidden Hills Subdivision has limited area for construction of a septic
system due to a steep slope to the east and south. We have located an area with
acceptable soils, but it is situated slightly more than 25' from a break in grade greater
than 25%. The alternate site at its closest point is 10' from the break. We are therefore
applying for a waiver allowing placement of the absorption trench at the location shown
on the Site Plan. The attached cross section of the property shows the 25% slope from
2.5' above the distribution does not daylight.
Subsurface soil on the lot absorbs water at a rate less than 5 minutes per inch. It is
highly unlikely septic effluent will migrate laterally. We therefore recommend a waiver
be issued allowing placement of the new absorption trench within 35' of a slope greater
than 25%.
Sincerely,
Michael E. Anderson, P.E.
ee~?OFESS~
Municipality of Anchorage
P.O. Box 196650 · 4700 Elmore Road
Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997
http:l/www, muni.or,cl/Onsite
Development Services Department
On-Site Water and Wastewater Pro.qram
,epa]-tment
**** VARIANCE/WAIVER REVIEW ****
WP, g: OSPl11001 HA#: ~ Permitg: OSPl11000
PID#: 011-121-45
Legal Description: Hidden Hills, Block 1, Lot 20
Engineer:-~q3--~ vx t~r'~*t.q ~'v~. CO_J-
Applicant: Scott Stuart
Your request for a waiver of the required 50 feet horizontal separation from the absorption field
to a slope greater than 25% has been approved. The approved separation distance is 35 feet.
This waiver approval applies to the existing absorption field to a slope greater than 25%
separation only. Any future upgrade to the on-site wastewater disposal system will require all
separation distances be met or another approval from this department.
Waiver is Granted: X Waiver is not Granted:
' Approved bY'~, d
Date: 1/3/11 .
( ./Name of Reviewer
Re~7,g: 016528 Amount: $200.00 Date Paid: 12130/10
**** VARIANCE/WAIVER REVIEW ****
ENGI iEERIN'G )UP,
;ONSULTANTS ", GENERAL' ;ONTRACTOR
IC"O~GE. ~. ggs07 * ~"ONE: (g07)557-' 7g * F~: (go7)3~-
ITEST HOLE
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK. 99507 * PHONE: (907)557-6179 * FAX: (907)538-524,6 * WEBSITE: gamesaengineerlng.co
LEGAL DESCRIPTION:
PERFORMED FOR:
ORGANICS
SP-SM
16.4'
SOIL CLASSIFICATIONS
GW ~ ORG
GP HL
GM CL
GC OL
SW MH
SP CH
SN OH
SC
DEPTH TO
GROUNDWATER DATE
DRY 10/14/10
DRY 10/22/10
DATE READING CLOCK NET TINE WATER LEVEL NET DROP
TIME (I'fllNUTES) READING (INCHES)
10/15/2010 1 8:45 - 6,, _
2 8:46 1 O" 6"
5 8:46 - 6,, _
4 8:47 1 O" 6"
5 8:47 - 6,, _
6 8:48 1 0" 6"
7 8:48 - 6- _
8 8:49 1 O" 6"
9 8:49 - 6- _
10 8:50 1 0" 6"
11 8:50 - 6- _
12 8:51 1 0" 6"
PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES
SOILS LOGGED BY:
TEST RUN BETWEEN 5.0 FT. AND 6.0 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: r--lYES
ROB CAMPBELL PERCOLATION TEST PERFORMED BY:
· NO
ANDREW GRAY
COMMENTS:
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS I~E~-/~RMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: I~/d~/t *
(;ARNESS EN~INEERINC-C;RO'U'P, Ltd.
ISOIL LOG - PERCOLATION TESTI
:St-~ ORGANICS ....
' .... * ~ ITEST HOLE ~2
.........
~ GC OL
' ~ ~ SW ~H
5--' ' SM OH
7~
8~ ' DRY 10/14/10 -= .......... m~__~__~l-' ~,
SP-SM DRY 10/22/10 ~' / ~ --~ ~~--} ~-~-~-~-'
[~, DATE READING CLOCK NET TINE WATER LEVEL NET DROP
11
~ TINE (~INUTES) READING (INCHES)
12 ~ ~<~, 0/15/2010 1 4:00 - 6.. _
2 4:10 10 1" 5"
15 ~ ~, 3 4:10 - 6.. _
4 4:20 10 1" 5"
1 ~ ~ ~' 5 4:20 - 6- _
~_"" ' 6 4:30 10 1" 5"
15 ~ ~<~ 7 ~:30 - 6.. _
"" 8 ~:40 10 1" 5"
16~ 6"
9 4:40 - -
B.O.H. ,,
17 ~ 10 4:50 10 1
11 4:50 - 6,, _
18~ 12 5:00 10 1" 5"
PERCOLATION RATE 2 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES)
19~
TEST RUN BETWEEN 5.5 FT. AND 6.5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORHED: ~ YES ~ NO
SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST RERFORHED BY: ANDREW GRAY
CONNENTS:
PERFORMED BY GEG, Ltd. I, JEFFR~ A. GARNESS, CERTI~ THAT THIS WAS ~E~ORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ~ /~/1~
I
DEPTH TO DATE
GROUNDWATER
DRY 10/14/10
DRY 10/22/10
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 20, BLOCK 1, HIDDEN HILLS SUBDIVISION
GENERAL:
The scope of this project includes the procurement and placement of a new
1,000-gallon septic tank at the location shown on the Site Plan. Work also
includes the construction of a new 33' long X 3' wide X 7' effective depth
absorption trench at the location also shown on the Site Plan. The
distribution line in the trench will be placed at 4' below the existing ground
surface. Total depth of the trench will be 11' below the existing ground
surface. The new absorption trench and septic tank must be placed a
minimum of 100' from all private wells, 150' from Class C Wells and 100' from
any surface water in the area and 10' from the water service line proposed for
the lot. A minimum of 3' of cover is required over the absorption trench and
4' of cover over the septic tank.
Construction shall be in accordance with the approved site plan, design
drawings, Municipal Permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the location
of all lot lines. The Contractor must also verify the location of wells in the
area and assure that the separation distances are met.
Unless specifically agreed otherwise, the contractor shall be responsible for
final grading areas subsequently depressed from soil settling. Property
owner shall be responsible for revegetation of affected areas unless
specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified by the
Municipal Building Safety Division On-Site Water and Wastewater Program
for system installations. Owners installing their own systems must receive
prior approval from the On-Site Water and Wastewater Program. before
beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,000-gallon septic tank must be procured from an approved source
and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
Lot 20, Block 1, Hidden Hills
June 30, 2011
Page 2 of 3
COl
3. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches above
final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial
insulation.
6. A foundation cleanout shall be installed one to four feet from the building
foundation. Two cleanouts are required between the tank and the drainfield.
7. Final grading over the tank shall be such that a positive slope exists away
from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the design.
The bottom of the trench shall be within 2" of level.
Distribution piping must be placed level with perforations down atop a level
bed of drainfield rock. Rock should then be placed over the pipe to provide a
minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield rock
and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations shown on
the design. The portion below ground must be perforated.
Contractor shall verify the septic tank and drainfield are a minimum 100' away
from any private water wells in the area, 150' from a Class "C" Well or 200'
from any community well.
Direct bury insulation must be placed over the distribution system if less than
3' of backfill depth is available. Finish grade over the trench must be
mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
A minimum 2' of accepting soil is required below the drainfield rock for a 5'
wide trench. All pockets of unacceptable materials must be removed and
replaced.
Lot 20, Block 1, Hidden Hills
June 30, 2011
Page 3 of 3
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic tank
manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and
solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662
or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the
#200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These inspections
must be conducted under the supervision of a professional engineer registered
in the State of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled.
The second inspection must be conducted after the placement of the geotextile
fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No
backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction notes
for use in preparing the certified as-built of the completed system.
On-Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage. AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSPl11000
Tax Code Number: 01112145000
Work Type: Septic Initial
Permit Effective Dates: January 04, 2011
to January 04,2012
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: HIDDEN HILLS
Site Legal Address: HIDDEN HILLS BLK 1 LT 20 G:2222
Owner/Address: STUART ELIZABETH
8008 INGRAM ST ANCHORAGE AK 995023998
Site Mailing Address: 6470 QUIET CIR, Anchorage
Lot Size in Sq Ft: 20616
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field N Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By: / ~,~ ,.~.--~-/ Date:
Issued By:.~ ~J~/~-~ Date:
Municipali_~ty__ o[ Anc~_~__horage
P.O. Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997
http:llwww.muni.or.qlOnsite
Development Services Department
On-Site Water and Wastewater Program
~epartment
VARIANCE/WAIVER REVIEW
WP~: 0SPl11001 HA#: Permit~: OSP111000
PID#: 011-121-45.
Legal Description: Hidden Hills, Block 1, Lot 20
Engineer: GEG.
Applicant: Scott Stuart
Your request for a waiver of tho required 50 foot horizontal separation from tho absorption field
to a slope greater than 25% has be~n approved. Tho approved separation distance is 35 foot.
This waiver approval applies to tho existing absorption field to a slope greater than 25%
separation only. Any future upgrade to the on-site wastewater disposal system will require all
separation distances bo mot or another approval from this department.
Waiver is Granted: X Waiver is not Granted:
Approve ( / Name of Reviewer
Rec#: 016528 Amount: $200.00 Date Paid: 12/30/10
**** VARIANCE/VVAIVER REVIEW ****
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Bragaw St.
P.O. Box 196650
Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINOLE FAHILY DWELLING
oSP litOOO o%¢'~loo~
Parcel I.D. 011-121-45
Property owner(s) sco-n- STUART
Day phone 244-8368
Mailing address
6470 QUIET CIRCLE * ANCHORAGE, AK * 99502
Site address 6470 QUIET CIRCLE * ANCHORAGE, AK
Zip Code 99502
Legal description (Sub'd, Block & Lot) HIDDEN HILLS S/D; BLOCK 1, LOT 20
Legal description (Township, Section & Range) N/A
Lot Size Sq. Ft.
Number of Bedrooms
THIS APPLICATION IS FOR ( [] all that apply):
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
Permit/Rush Fees:
Date of Payment:
Receipt Number:
(Rev. 11/05)
Waiver Fees:
Date of Payment:
Receipt Number:
GARNESS ENGINEERING GROUE Ltd.
CONSULTANTS & GENERAL CONTRACTORS
December 2, 2010
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Road
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: Proposed Septic Upgrade for Hidden Hills S/D; Lot 20, Block 1,
To whom it may concern:
The subject property has a mobile home on it that is served by a class "C' community well and a
private holding tank (a 3000 gallon S.T.E.P. tank installed in March 2005). The mobile home is
to be removed and replaced by a new 3 bedroom house and the holding tank will be replaced
with a septic system We are proposing to use the existing tank and plumb it to serve the new
drainfield. We are also proposing to install a new deep trench type drainfield. Two test holes
were excavated on the property. The drainfield is designed around the 30 foot radius of test hole
#1. Comments regarding the design are summarized as follows:
1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring,
and the percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications°
3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic
system.
4. TOPOGRAPHY: As can be seen on the attached design drawing the average topography in
the area of the proposed drainfield is relatively flat. However, the proposed location would place
the drainfield approximately 35' from slopes greater than 25%. We request you waive the
distance from 50' to 35'. The following items are justification for the waiver.
· The soils from test hole #1 were classified as SP-SM and had a very fast percolation rate.
These soils will allow for rapid downward migration of the effluent and minimize lateral
movement towards the cutbank.
· As can be seen on the attached drawing, at a 25% slope (starting 2.5 feet above the drainfield) the
potential point of daylighting is greater than 50' horizontally from the trench.
We are unaware of any adverse impacts with the granting of this waiver would create.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com
5o SAND FILTER: Typically, a sand filter is required for systems designed around percolation
rates less than 1 minute/inch. We believe the insitu sandy soils will act as a sand filter and
request you waive this requirement.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems~ If you have any questions~ please contact us at 337-6179o Thank you for your
assistance.
Sincerely, I~
~IQ~o ss, .E, M.So
NOTE: Attached is a site plan drawing, a design drawing, one soil log, which are all part of the
design package for this septic system. (Contact G.E. G. Ltd. for 7 page construction specification
letter.)
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com
I I HIDDEN 'HILLS S/D
/ / /C'~~~"H~-~/D
, , / / /~ ,' X ~.
I I / / /~ I X /~
, I / LOT 23~BLOCK 1 ~ / . /
...... u V H~DD[N ~S-S/D ~/ ,/
Io -
o LO~ 2~. B~OC~ ~
I I ~ t~ Hm~ H,~S S/~I ~~
KINCAID ACRES S/D: ~ ~--~S ', X. ~ ~x. I ~ } /'
LOT 3, BLOCK 1 ~ ~--~ k '~ _ ~ ~
, -
/ ~e/ I I / -~ ~ ~ ~ ~ ~
· ~ L ~, ~ I
.... ~ ..... ~ _ ~ ~ ~
~ x , Y ~~ / J l~ ~c
__~ ,
~ ~~ /Y~_ L...... i
.... ~ -' - ,-= I ~~ ~'L~
OA.:~'NE, SS ENOIN':EERING
1701 E. ~R ~. SU~ 101 * ~C~ ~ ~7 * ~ONE (907)337-61~ * F~ (907)3~-3246 ~S~ .... g .... gin. Hng.=m
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
LEGAL DESCRIPTION: D~WN BY:
HIDDEN HILLS BLOCK 1, LOT 20 P.N.B,
SITE P~N 10/1/2010
DESIGN CRITERIA: GEG, Ltd~ HAS A7 PAGE SPECiFiCATION
LETTER THAT PERTAINS TO THIS DESIGN.
NUMBER OF BEDROOMS: .3 TO OBTAIN A COPY OF THE LETTER
GALLONS PER DAY (GPD): 450 CONTACT GEG. BY PROCEEDING FORWARD
PERCOLATION RATE/S: <1 & 2 MIN/IN ._~ WITH THIS INSTALLATION, THE ENGINEER,
PROPOSED APPLICATION RATE: 1o0 WELL DRILLER, CONTRACTOR AND
MINIMUM DRAINFIELD SO.FT.: 450 PROPERTY OWNER AGREE THAT THEY
HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT THE TERMS AND ~
DRAINFIELD DESIGN: CONDITIONS~ED. ,)O~
MAXIMUM DEPTH: 10' ~ ~ ~
WIDTH: .3' ---'-'--- ~ ~'
,.,_ ......... ** . BE MOVED TO PROPOSED
EFFECTIVE: 7.0' -: .- / ~ /~ \~ / '-'/
REDUCTION FACTOR: N/A :
NOTE: CONTRACTOR h.L '/ ~ ~ I ' /
SHALL HAVE ALL ~'X,,. / ..~(/~',~"-~ ~~~--'-~'
I~ ~ D:LL~IZD/Li~LU ~ OF PROPOSED 3 / .~..,--INSTALL fCO I 50 lOJ~.~
PROFESSIONAL LAND \ ~ ~AD~;M-~S~ ~ I ~ /
VEYOR PRIOR TO ProPOSED :)cation I
S U R ,-...,..} /- P R_O_P_O S_E_D_ _q )_CATIONi /
CONSTRUCTION ~ ~ ///'~.~ [ FOR STEP TANN y j
CO /
NOTE:WATERLINE ~ ~ / TH#2~ 'i "-"~ ..~' ...,,,.-,~ . ~ /
: LOCATION ~S , \ ~/ I ,-, (~,.~,' .,-'~ I ' /
UNKNOWN. \ ] __~__MH-- '~ I I i ..,-'
J CONTRACTOR SHALL \ \ /--PROPOSEDI ~
HAVE THE WATERLINE \ \ co /MT DRAINF~E~I~ I
LOCATED BEFORE ,\ ' ~ __-- _____ __-- '-a : I I ~ '
i/ INSTALLATION. ~3~ ~ / ,~,"'-h / `35' PROPOSED / / /
/ \ ~ ~ ,~XY' ~ WAIVER TO
(~'~' ~' / 25+= SLOPE
~_\ / _ .-,, ~--R~g~VE (_..~ / I ~ ! t._$ E PTI C
.,.-- /\ /
LEGAL DESCRIPTION· DRAWN BY: ~'(Jh~P~: '/' ~3E-79~3 o-' ~'/
HIDDEN HILLS S/D; BLOCK 1, LOT 20 A.J.G. ~,~:~,.
DESIGN OF PROPOSED SEPTIC SYSTEM 11/2/2010 '~,~,~~
PROFILE
DRAWING
I1 "=1 O'
PROPOSED 55' WAIVER TO 25+% SLOPE
i' 50'+ TO POTENTIAL SURFACING POINT
I
· REQUESTED .35' WAIVER TO 25+% SLOPE
'10' ~
PROPOSED10, TOTAL DEPTHORAINFIELD: ~u~C~ p~W_A¥) ~,~
' 7' EFFECTIVE DEPTH ~"~). _ ~0~
3' WIDTH ~ ~
GARNESS
PREPARED gOR: ..
SCOTT STUART
LEGAL DESCRIPTION'
~PE OF WORK:
PROFILE DRAWING OF PROPOSED WAIVER 11/2/2010
(Rev. 01/05)
~E
E
I
i
.I
Z
LOT 20, BLOCK 1, HIDDEN HILLS SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:,.
Three Bedroom Home Deep Trench System
Perc. Rate: 1-5 Min./Inch 1.000 Gallon Septic Tank
Application Rate: 1.0 GPD/SF 5' Drainfield Rock
3 Bedrooms X 150 GPD/1 GPD/SF (Application Rate) -- 450 SF Absorption Area
450 SF/10 SF/LF = 45 LF Trench Length
THEREFORE: Construct a 45' Long x 4' Wide x 5' Effective Depth Absorption Trench at the Location
Shown. Flow Line Elevation in Trench to be 7' Below Original Ground Surface. Total Depth to be
12' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench.
Maintain 10' Separation from Water Service in the Area and 150' From Class C Well.
1611
1011
Natural
Backfill
Geotextile
Fabric
4" Perforated
PVC (Holes Down)
Drainfield Rock
TYPICAL DEEP TRENCH SECTION
(NO SCALE) ..~... .............. ~.
NOTE: Grade Area Over Trench to Drain Away. ~
Minimum 6' Separation From Bedrock. ~%....~.....;.~.'.'~ ........... .H~ ~ ...... ~.....~
Minimum 4' Separation From Groundwater. ~'~(~
Minimum 100' Separation From Private Wells in the Area ~'~'"&~;;;~;'E;~;;~'¢"':~ '
M,n,mum 150', Separation From Class C Wells in the Are~.-~ No. cs-4~1 /~'~
Minimum 100 Separation From Su~ace Water or Streams. ~,~;-...~..-%~
CHECKED BY DATE
SCALE
GARNESS ENGINEERING GROUP, Ltd.
3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK. 99507 * PHONE: (907)357-6179 * FAX: (907)3~8-3246 * WEBSITE.:
LEGAL DESCRIPTION:
PERFORMED FOR:
SP-SM
16.4'
TEST #1
SOIL CLASSIFICATIONS
GW ~ ORG
GP ML
GM CL
GC OL
SW NH
SP CH
SM OH
SC
DEPTH TO
GROUNDWATER DATE
DRY 10/14/10
DRY 10/22/10
DATE READING CLOCK NET TIME WATER LEVEL NET DROP
TINE (MINUTES) READING (INCHES)
0/15/2010 1 8:45 - 6,, _
2 8:46 1 0" 6"
3 8:46 - 6- _
4 8:47 1 0" 6"
5 8:47 - 6- _
6 8:48 1 0" 6"
7 8:48 - 6- _
8 8:49 1 0" 6"
9 8:49 - 6- _
10 8:50 1 0" 6"
11 8:50 - 6,, _
12 8:51 1 0" 6"
PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 5.0 FT. AND 6.0 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: [] YES · NO
SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST PERFORMED BY: ANDREW GRAY
COMMENTS:
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS I~EPC-ORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
GARNESS ENGINEERING GROUP, Ltd. ~ i4~!U~ .....-z.t~
CONSULTANTS & GENERAL CONTRACTORS (Ff.'C[.:
=~"~""~.su~`°"~E~."~""~"E~<~=-~r~3~'~`~6~wE'~s"~~L LOG- PERCOLATION TESTI .......
PERFORMED FOR. SCOW STUART DATE ~
TEST
HOLE
DEPTH ~
(feet) ~ ORGANICS
SOIL CLASSIFICATIONS~'\
,.... ~
,.":-_":.t t [ {I,_...,~,,.;-"'::tI* 11~~ ~/, _ z ,'-...- i,,"
~ __ ,'-' .4 !; ti .-:.....,.'-.,k...-'..~;"--: G P Pi L
--"""'" ',,Y
,%'.M',~ ?1 o o, SW NH
'z ~'. ;~ SP CH
i',,
~ ;':::tI*;I DEPTH TO DATE , x. /', ; -A; _....*/ /!ii
,...., --. . , ___ ,-ffl-.~-~._._- _~-/ L ......
...... -__~'
:':::ti*" GROUNDWATER - · , ,
,',', lO/14/lO ~'Y*7-- / .......
e- ;':::tI*;I DRY ,--:5- ......... "L...__k_ .-L ~" \ \ ~----
,%" SP-SM DRY 10/22/10 \ /
;_':::ti*II -
,...,'-'.
· ~ ~,.e+l?lI
t%e+l?ll CLOCK NET TIME WATER LEVEL NET DROP
11 -- '""'.'~'~ I t II DATE READING TIME (MINUTES) READING (INCHES)
%' "~ f,J,'ll - 6"
"'"' +17 II 10/15/2010 1 4:00 -
.' .."l' I t Il'" .,I, ! ~, '1'1
12 -- i'.'~'.'.t ~ I {I 2 4:10 10 1" 5"
- -
:'." +17 II 4 4:20 10 1" 5"
14 %' · 5 4:20 - 6- -
i~iiIt I tI 6 4:30 10 1" 5"
= _ -
-.-.l ;lf
/I
1 s - ;::d I * II s 4:40 10 1 5"
_~.' .· 9 4:40 - 6" -
17 B'O'H'I 10 4:50 10 1" 5"
/
11 4:50 - 6- -
1~i/ 12 5:00 10 1" 5"
PERCOLATION RATE 2 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
19-
TEST RUN BETWEEN 5.5 FT. AND 6.5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: · YES [] NO
SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST PERFORMED BY: ANDREW GRAY
COMMENTS:
PERFORMED BY GEG, Ltd. I, dEFFREY A. GARNESS, CERTIFY THAT THIS WAS ~ER/CORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ti
i
DEPTH TO DATE
GROUNDWATER
DRY 10/14/10
DRY 10/22/10
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 20, BLOCK 1, HIDDEN HILLS SUBDIVISION
GENERAL:
The scope of this project includes the procurement and placement of a new
1,000-gallon septic tank at the location shown on the Site Plan. Work also
includes the construction of a new 33' long X 3' wide X 7' effective depth
absorption trench at the location also shown on the Site Plan. The
distribution line in the trench will be placed at 4' below the existing ground
surface. Total depth of the trench will be 11' below the existing ground
surface. The new absorption trench and septic tank must be placed a
minimum of 100' from all private wells, 150' from Class C Wells and 100' from
any surface water in the area and 10' from the water service line proposed for
the lot. A minimum of 3' of cover is required over the absorption trench and
4' of cover over the septic tank.
Construction shall be in accordance with the approved site plan, design
drawings, Municipal Permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the location
of all lot lines. The Contractor must also verify the location of wells in the
area and assure that the separation distances are met.
Unless specifically agreed otherwise, the contractor shall be responsible for
final grading areas subsequently depressed from soil settling. Property
owner shall be responsible for revegetation of affected areas unless
specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified by the
Municipal Building Safety Division On-Site Water and Wastewater Program
for system installations. Owners installing their own systems must receive
prior approval from the On-Site Water and Wastewater Program. before
beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,000-gallon septic tank must be procured from an approved source
and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
Lot 20, Block 1, Hidden Hills
June 30, 2011
Page 2 of 3
3. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches above
final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial
insulation.
6. A foundation cleanout shall be installed one to four feet from the building
foundation. Two cleanouts are required between the tank and the drainfield.
7. Final grading over the tank shall be such that a positive slope exists away
from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the design.
The bottom of the trench shall be within 2" of level.
Distribution piping must be placed level with perforations down atop a level
bed of drainfield rock. Rock should then be placed over the pipe to provide a
minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield rock
and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations shown on
the design. The portion below ground must be perforated.
Contractor shall verify the septic tank and drainfield are a minimum 100' away
from any private water wells in the area, 150' from a Class "C" Well or 200'
from any community well.
Direct bury insulation must be placed over the distribution system if less than
3' of backfill depth is available. Finish grade over the trench must be
mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
A minimum 2' of accepting soil is required below the drainfield rock for a 5'
wide trench. All pockets of unacceptable materials must be removed and
replaced.
Lot 20, Block 1, Hidden Hills
June 30, 2011
Page 3 of 3
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic tank
manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and
solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662
or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the
#200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These inspections
must be conducted under the supervision of a professional engineer registered
in the State of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled.
The second inspection must be conducted after the placement of the geotextile
fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No
backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction notes
for use in preparing the certified as-built of the completed system.
Municipality of Ancho gc.:
~.;'
Mayor Mark Bqq~ch
47(X) Bra#aw Strcct · Anchorage, AIaM~
Building S,'drcty I)ivlsion
July 14, 2005
RF_JMAX Properties, Inc.
2600 Cordova Street, Suite 100
Anchorage, Alaska 99503
RE:
ON-SITE WASTEWATER DISPOSAL AND WATER SUPPLY SYSTEM,
IIlDDEN 1fILLS SUBDIVISION, BLOCK 1, LOTS 19 AND 20, PARCEL IDS
//011-121-44 AND 011-121-45
Dear Mr. Blake Butler,
This letter is a follow-up to our conversation this afternoon. It is my understanding that
you are the real estate agent representing the seller of Lot 19 and a person has entered into an
agreement to purchase Lot 19. As I informed you in our conversation, certain steps need to be
taken for the title transfer and subsequent redevelopment of Lot 19. The follow sequential steps
are necessary;
1. As indicated in my April 27, 2005 letter, a portion of the on-site wastewater disposal
system located on and serving Hidden Hills Subdivision, Block 1, Lots 19 and 20 has
been decommissioned. The portion of the wastewater disposal system located on Lot 20
has been decommissioned and the remaining portion of the system located on Lot 19 is
no longer in compliance with municipal code. Therefore, the remaining portion of the
wastewater disposal system on Lot 19 must be permanently decommissioned.
Decommissioning of the wastewater disposal system will be required in order to obtain
the Certificate of tlealth Authority Approval required in/13.
2. It is my understanding the mobile home on LOt 19 is uninhabitable and the buyer plans to
remove it following title transfer. In the intermittent period, the mobile home should be
secured against entry and occupancy.
3. ACertificateofHealthAuthodtyApproval for the water supply system on Lot 19should
be obtained from this department prior to title transfer.
4. A recorded agreement to run with the properties should be made between the Lots 19and
20 property owners for the sharing of the Lot 19 water supply well.
5. A wastewater disposal system must be constructed to serve Lot 19 prior to
redevelopment. There appears to be two potential options for a wastewater disposal
system to serve Lot 19. Option #1 - A permit be obtained from this department for the
construction of an individual on-site wastewater disposal system on LOt 19. This option
would require the appropriate separation waiver be obtained from the Alaska Department
of Environmental Conservation (ADEC) for the Class C public water supply system on
LOt 19. Option #2 - A permit be obtained from the ADEC for construction of a
wastewater disposal system on LOt 20 that serves Lots 19 and 20. A 3,000 gallon septic
tank has already been installed on Lot 20 for the potential of a future shared wastewater
Community, Securily, Prosperity
disposal system. This option would likely require both parties to entire into a recorded
agreement to run with the properties for the sharing of the wastewater disposal system.
Please be aware that Anchorage Municipal Code (AMC) 15.65.040 prohibits the
installation ofa wastewater disposal and/or water supply system in a location that would prohibit
future residential use of an adjacent lot. Therefore, this department is unable to issue a
wastewater disposal system permit for Lot 19 because it would prohibit the installation of a
water supply system on Lot 20. Likewise, this department is unable to issue a water supply
permit for Lot 20 because it would prohibit the installation of a wastewater disposal system on
Lot 19.
Based on the site plan of the subject properties provided by Gamess Engineering Group,
there does not appear to be sufficient area for both properties to have an individual on-site
wastewater disposal and water supply system. Therefore, it is to the mutual benefit of the Lots
19 and 20 property owners to come to a recorded agreement regarding the sharing of the water
supply well on Lot 19 and potentially the sharing of a future wastewater disposal system on Lot
20. We hope that this letter aids each property owner to understand the need to work together to
resolve the wastewater disposal and water supply system issues of the subject properties.
If you have questions regarding this letter, please contact me at (907) 343-7904.
Sincerely,
Julie Makela, P.E.
Civil Engineer II
On-Site Water & Wastewater Program
Cci
Ms. Gerhardson, Hidden Hills Subdivision, Block 1, Lot 19 property owner
Ms. Colleen Johnson, Hidden Hills Subdivision, Block 1, Lot 20 property owner
Mr. TJ Justice, Hidden Hills Subdivision, Block 1, LOt 19 property buyer
Ms. Dar Walden, RE/MAX Properties, Inc.
Mr. JeffGamess, P.E., Gamess Engineering Group, Inc.
Ms. Venessa Blevins, P.E., ADEC Division of Environmental Health
Mr. Bill Rieth, P.E., ADEC Division of Water
;W04046;5 - 031-121-45
CONSULTANTS & GENE~LCON~O~RS F~ ~'; ~ ..... } ...... :.:.,I ~
Municipality of Anchorage
e Development Services Department .c'-' ~'~=~-
Building Safety Division
On-Site Water & Wastewater Program, 4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci,anchorage.ak.us (907) 343-?904 Poge 1
On-Site Wastewater Disposal System and/or Well Inspection Report
Perm;t Number:. SW040483 PID Numbe~ 011--121--45
Nome:
COLLEEN JOHNSON Wastewater System: cI New · Upgrode
6470 QUIET CIRCLE * ANCHORAGE, AK. 99502 ABSORPTION FIELD
Phone: NO. of ~edrooml:
(907) 339-6859 3 rlD~ep Tm•ch (~ Shallow Trench [] Bed []Mound []O~her
LEGAL DESCRIPTION ~ "~ "' ~ ~ "~
1 20 HIDDEN HILLS ~./
WELL: ONe. D..
SEPARATION DISTANCES •Be.,~¢ m,oldlno C~S.T.r.p. •Oth,r*
?onk Fmld Stotion Tonk S~ ~ ANCHORAGE TANK .3000
Well - - - 75'+ 25'+ ~ STEEL "~ *~ '"'"~= 2
s.,o=o wo~.,- - - ~oo'+ - LIFT STATION
Lot Une -- - -- 5'+ -~.
~o~..otio. _ - - ~'+ - ~. ~ ,~\~G
Remorks: BENCH MARK
· THIS IS A .3/16' POLY COATED HOLDING TANK TOP OF' MANHOLE LID
WITH A MANHOLE ON THE END FOR POSSIBLE
FUTURE USE OF A PUMP VAULT, AND DRAINFIELD. ~ ~
99.32
Inspections performed by: GEG, Ltd. Dates: 1st ,3/2/2005 'r_-..· ~~''': 9
3rd - ~ ,,~ '...le f~, x,~(:;o hess.:
Development~Servic. es Department Approval (0~.~; -. I~E-7~ ..." ~,~
Reviewed and approved by Date: .~/~.~ I.o~-~
P£RUR NUUS£R:
swo4o,83 AS-BUILT DRAWING
011-121-45
.... ~ ,, CIRCLE ~ ~ I / ;
~/ ./ /x x xx /..~ ...... x.
...... ~~ ...... ~ / ~ t
~ ~ ~x~ ~ ~ ~ ~ ~~' / ..~ '
",.- A ~ -_~. ~ ., _J--' ~
C01 45.69 32.52 // ?--W~,~--%
/ ~%3 ~ / ....... '~ .
C02 168.35i79.15 //C-' ~ ~ / __ --- ___ ~-
MH 8306 11272 ~ ~' /~ / ~ ~ '
. . ~_ .. / ~ /
, ~- // ~ ~ r/
PREP~D FOR' PHONr N.M ....... I
COLLEEN JOHNSON J 559-6859 I 2 OF 5 ~ ~ 'd~
AS-BUILT fOR NEW SEPTIC SYSTEM 3/14/200~~4~
~: AS BUILT DRAWING
SW040483 - PARCEL lO NUUBER
F1NAL CRADE
TOP OF TAHK
/ ~/16" PO~ COATED --
/-- ADV~TEX TANK w/
/ BAFFLE. BEING USED
~ O~eUNOI ~ A HOLDING TANK.
~EP~ED FOR- PH N '
UULLLLN JOHNSON [ 339-6859
HIDDEN HI~ SUBDIVISION; LOT 20, BLOCK 1 R.~.L. v
MUNICIPALITY OF ANCHORAGE
Development Services Department
On. Site Water& Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Nov 22. 2004
Expiration Date: Nov 22, 2005
Permit Number: SW040483
Legal Description: HIDDEN HILLS BLK I LT 20
Design Engineer: 0855 Garness Engineering Group, LTD
Owner Name: COLLEEN JOHNSON
Owner Address: 6470 QUIET CIR
ANCHORAGE, AK 99502-3938
Parcel ID: 011-121-45
Site Address: 006470 QUIET CIR
Lot Size: 20616 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
[] Disposal Field [] SepticTank [] Holding Tank [] Priw
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ),
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By: ~
Issued By: ,~
Municipality of Anchorage
Development Services Department
Building Safety Division
On-SRe Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
Parcel I.D.
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR ~, SINGLE FAMILY DWELLING
Permit Number
Property owner(s)
Mailing addres~ (1)
Mailing address (2)
COLLEEN JOHNSON
6470 OUIE'T CIRCLE * ANCHORA(~E. AK
Day phone
Zip Code
243-1099
Legaldescription (Lot, Block & Sub'd.) LOT 20. BLOCK 1: HIDDEN HtLLS SUBDIVISION
Legal description (Section, Township & Range) N/^
Lot Size Z. C9 I ~ I ~ Acres/~) Number of Bedrooms
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
Well Only []
Water Storage []
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Poor
Jacuzzi
Water Softening Unit
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes,
CARNESS ENGINEERING GROUP~ Ltd.
Permit Fees:
Date of Payment:
Receipt Number.
Waiver Fees;.
Date of Payment:
Receipt Number.
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS. ................
November 1 I, 2004
Municipality of Anchorage
Development Service Department
Building Safety Division
On-Site Water & Wastewater Program
4700 South Bragraw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
Ref: llolding Tank Upgrade for Lot 20, Block I; llidden Ilills Subdivision
To whom it may concern:
The existing 3 bedroom house is served by a class "C" well located on Lot 19, Block 1, and also shares a
community septic system both located on Lots 19 and 20. The septic system consists of two - 1000
gallon septic tanks located on lot 19 and a deep trench type drainfield with the majority of the trench
located on lot 20. There is an abandoned mobile home located on lot 19 and it is our understanding that
this trailer is to be completely removed. The property owners of lot 19 are requiring the owners of lot 20
to disconnect from the all portions of the septic system located on lot 19. The owners of lot 20 have hired
us to design a possible well site and a new septic system. There is only one location for a possible well
and will require the complete abandonment of the septic tanks located on lot 19. The owner of lot 20 is
not looking to drill a well at this time, but would like to reserve a site in the case that she will be need to
be served by her own well. As can be seen on the attached design, there are steep slopes along the east
property line. Given the possible 100 feet well radius and the setback from cutbanks, there is no location
for a conventional type septic system. We are proposing to have a 3000 gallon 3/16" poly coated holding
tank with a manhole installed in the northeast comer ofthe property. The tank is to be built with a baffle
in order to be used a possible lift station. The owner of Lot 20 is required to disconnect from the septic
system located on lot 19 as soon as possible. We request the permit be issued at your earliest connivence.
Prior to our submittal, this design was discussed with Dan Roth and received preliminary approval to our
proposed design. There are no surface waters within 100 feet ofthe proposed septic upgrade
I am unaware of ~']q~ adverse impacts this installation would have on adjacent wells or septic systems. If
you have an~, qu~'~t~ as, please contact us at 337-6179. Thank you for your assistance.
N(~TE.~Attached is a site plan dr~'ing, a desi~ drcving, a detail drmeing and a 5 page const~ction
spec~cation letter which are all part of the desi~ paclage for this septic system.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: garnessengineering.com
I / / .'~ / LOT 2~, BLOCK
I I / / // N
~ I /I t ~ /
.... I / I LOT 23. ~ I N / / ·
................ ~ (/ ~ HtDOEN HI~ S/D ~/
................ ~ ,/~ {~__ ~, .
I I I ,0 LOT 22 .L~. 1 ~~------~--~T--~
., ,g --,
I '~ I ' / ~ w[~ ~ ~
-::-=w*~7~ F~ ~, ,, : ~ :
~. , -.,. ...... ~:--~Z_, t~ ~,.,.
, , , ,- ~~,~ ~
............... ~/q--~; '!~ ~ ~ '~
LOT 4D, B~ I /, I ~ I~_ ~ ~T~~ -
./ i i ~, ~:~ ~ ,!,
-- , ~ :-~ ~ -'~- /
i~ ,LOT 42. ~K I ~. - I Y ~~ ' " ' ' ' '~
................. I ~ T& ..... f I
....................... J.L.M.
GARNESS ENGINEERING GROUP, Ltd. s~:
~ CONSULTANTS & GENE~L CON~CTORS 1"
HIDDEN HILLS SUBDIVISION; LOT 20, BLOCK 1
SITE P~N FOR POSSIBLE WELL LOCATION AND SEPTIC SYSTEM
t NOTE: TIlE POSSIBLE WELL ~T[ IS FOR FUTURE USE. NOTE: THE CONTR~TOR SHALL HAVI~ THE ~OLO~ING ~EMS
~ ~ ' UUl~/ X ~ coup~m[~ T~K
I ~ ~ ~ ~, ~ ~ ~ M~HOLE ON END Or T~K
-~ ~ ~ ~ ~----~ L '"~ ~/t l
~ ~ . /~x ~ I ~"' II ~ ,/
// ~~A~/ ~~
// ~ ~NG ~ HOUSE ~
~,s ..~ ~ ~o .~ s~.~o. / ~_' .~' / ~ I
.... ~PED. ~D PLUGGED ~H 5 ~ OF ~ ~,,, ,~ ~ .'
~ ~/ ~ ; //' ~, .....
GARNES~ ENGINEERING G~OUP, Ltd. s~ ~.t.u.
CONSULTANTS&GENE~LCONT~CTO S ,~ -- ,~, ~::LI ...
COLLEEN JOHNSON 559-6859/243-1099 2 OF 5 ~"~ ~'~s:/"'~'
HIDDEN HILLS SUBDIVISION; LOT 20, BLOCK 1 ~e ~ ".
~[ OF WORK: -A~
DESIGN OF POSSIBLE WELL LOCATION ANN PROPOSED HOLDING TANK
PROPOSED 3000 GALLON
5/16" POLY COATED "ADVANTEX"
TANK WITH BAFFLE. TO BE USED
11/9/2004
GARNESS ENGINEERING GROUP, Ltd. ~
CONSULTANTS & GENE~L CONT~CTORS N.T.S.--
COLLEEN JOHNSON 559-6859~245-1099 ~ OF 5
HIDDEN HILLS SUBDIVISION; LOT 20. BLOCK 1
DETAIL OF HOLDING TANK DESIGN
GRE - 'R ANCHORAGE AREA BOR,..,GH
/,,.<, .,~, Department of Environmental Quality
~/ 3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATION ~l/~--I- (~i~2-¢ ~.~ LEGAL DESCRIPTION
SEPTIC TANK:
DISTANCE
FROM WELL
INSIDE LENGTH
NUMBER OF
N1ANUFACTU RER ~'-'~ ~?.~T z.'.~. ~?.~. MATERIAL ~12-t.~ COMPARTMENTS /
INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY/~¢='¢1'-¢ GALLONS,
DISTANCE FROM WELL
NUMBER OF LINES
ABSORPTION AREA
TOTAL LENGTH
FOUNDATION '~ /"t~ NEAREST LOT LINE /¢1'~ OF LINES
DISTANCE BETWEEN LINES TRENCH WIDTH ~ IN. TOTAL EFFECTIVE
SQ. FT. LENGTH OF EACFt LINE J ~! '~0t '
[~iE~?¢ 0,¢ '7-~,l~t~ lJ~-t 2.t DEPTH OF FILTER ~-~t'~"
DEPTH: TOP OF TILE TO FINISH GRADE J~-~)//MATERIAL BENEATFI TILE
IN.
TYPE - ~'~'~'~'~'~'~'~'~'~- ~',~ ,~ ;,/~ z/.;' ~;,' xl ,~ ! CONSTRUCTION
BUILDING NEAREST NEAREST
FOUNDATION__ LOT LINE SEWER LINE
DEPTH .... DISTANCE FROM:
CESSPOOL .... OTHER SOURCES
APPROVED DISAPPROVED REMARKS
SEPTIC SEEPAGE
, TANK SYSTEM
DISTANCES:
INSTALLED BY: ~'¢-%'L-[~'
SEWER LINE DEPTH:
PIPE MATERIAL'
LOT SLOPE:
REMARKS:
DATE
DIAGRAM OF SYSTEM
G.A.A.B.
Form EQ-032
GREA ,2 ANCHORAGE AREA BOR,.. ~GH
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 "C" STREr:"T ANCHORAGE, ALASKA 99503
SEWAGE DISPOSAL SYSTEM APPLICATION AND PERMIT
'--EGA,-E, ESDR[PT,ON _ ":/'
INSTALLATION OF: SEPTIC TANK __ ,'~ SEEPAGE PiT DRAIN FIELD .
SO,L TEST RESULTS /~'__ ¢ Z";/~-~'
COMPLETION DATE ANTICIPATED __~:~,~,'¢O'~./J..
NOTE: THIS PERMIT 15 NOT VALID WITHOUT SOIL TEST
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF' ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL. QUALITY AUTHORITY WILL {~E SUBJECT TO PROSECUTION.
SEPTIC TANK SiZE _,/~.t'~J'~-~¢~.~: - TYPE ____/.,.~:T~'I~/"~/~ ~/.. -- SEEPAGE AREA SiZE TYPE
MINIMUM DISTANCES, REQUIREMENTS
FOUNDATION TO SEEPAGE~/4,.T, DRAIN FIELD
SEPTIC TANK TO SEEPAGE P~P'WALL
TO NEAREST LOT LINE.
WELL TO SEPTIC 'rANK
DRAIN FIELD .....
WATER MAIN TO SEPTIC TANK
DRAIN FIELD
SEPTIC TANK,
., ALSO CONS[DER AREA WELLS,
TO RIVER, LAKE, STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION ~ FEET INTO UNDISTURBED SOIL.
FITTED WITH AIRTIGHT REMOVABLE CAPS
GRAVEL r~ACKFILL
CONFORM '1'O BOROUGH REGULATIONS REGARDING INSTALLATION.
OR
DIAGRAM OF' SYSTEM
I CER'rIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. I r~O 0e~ci~y] ~J. at ~l.j.~ ~ ~Z~ Co~'~ a ~ o~
~ee .~; b,~. Z- underst~d ~ umraU~w~$ ~:~~~ld ~e be~s ad~e~.
DATE ~~ ') ~ A~L' (;ANTI~ ~ ' ~ NAIf u R ~ ~~~:;~ ~
FORM no. gQ-OI6 [~
GREATER ANCIIOI(t\F,L /',V. LA UOROUG,,
I)epargment of EnvironmenLM Qua liLy
3330 "C" Street
Anchorage, Alaska 995f;3
SOILS J,()(~ PI.;I[OI,ATION
Performed for
Legal Uescril]tion:
lhis form re)orts: So{ls log__._x_
Dep th
Feet
] - Organic material~ roots~ etCo~ some
sandy silt
2 - USCS Class "OL"
_25_
3 - Grey sandy siit~ Sand fraction very
fine~ non-plastic
~ - USCS Class- SM/ML
6 - Sand content increases with depth~
still non-plastic
~ - USCS Class SM/ML
8 - NOTE
9 - Additional Samples to 12' depth
indicate that material changes to
l0 - S~d/SW.
Based on visual observation of sample-
It .- recnomend 175 Ft2 to 185 Ft2 Per
Bedroom at .$hi~ depth.
12
'13-
Was ground water encountered? NO. ......... If yes, at wna~ del;th?
Reading Date Gross Time Net Time , .~U~p~t'L_~_o._W_a_te__~]. Net urop
Percol a~ion rate mi nu[e.
Proposed installa'tio~T-~b~)~e Pit Urai,~ Field
Depth of Inlet .... 5_~_$ .......... · -
COMMENTS: Seccom~g_ 260_ S_%o_ Ft~ Semi, age wa!~ area. ~er bedroonN
inform~ion from yoga t~l '~he for~ of a well 1~{3 to indi~
It is thi~ ~iep~rtm~:f~t'~ policy t~at well p~r?~its are
~,nvati(l. Unti,1 further Infor~%atio~ i~ recolv~'~ from you
Principal Environr~enta% Co~troI Officer
GRE, R ANCHORAGE AREA BO, JGH /
I~/~ UJl zt~mlm ~ / 3~3o "c" STREET ANCHORAGE, ALASKA 99503
,.STAL'.^.,ON OF, SERT, TAN. "*. '-"--. DRA'N F,ELD -. .OTNE.
_--. ~ - . · . ¢ , _ ~ -. , ., .'/
FINANCED THROUGH TO BE INSTALLED BY
SOIL TEST RESULTS
NOTE= THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAl. QUALITY AUTHORITY WILL be SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE TYPe SEEPAGE AREA SIZE TYPE
MINIMUM DISTANCES, REQUIREMENTS
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGe PIT
SEPTIC TANK TO SEEPAGE Pit WALL.
SEPTIC TANK , SEEPAGE PIT
TO NEAREST LOT LINE.
DRAIN FIELD /~.. ~.~ t"
., DRAIN FIELD
, DRAIN FIELD
, SEEPAGE PIT ·
, DRAIN FIELD
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIP~IGt~PJPE$ ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLAtI~O_N.
DIAGRAM OP' SYSTEM
I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGB ORDINANCE NO. ~S.¢JS~AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
FORM NO, EQ-016
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 A~chorage, AK 99519-6650
www,ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH .b, UTHORITY ,b, PPROVAL
FOR ~, SINGLE FAHILY DWELLING
ParcelI.D. Ot~' ~'2~'L~
1. GENERAL INFORMATION
Expiration Date: / I - 3'- D ¢
Completelegaldescription HIDDEN HILL SUBDMSION; LOT 20~ BLOCK 1~
Location (site address or diractions) 6470 QUIET CIRCLE * ANCHORAGE~ AK 99502
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
COLLEEN JOHNSON Dayphone 339-6859
6470 QUIET CIRCLE * ANCHORAGE~ AK 99502
Day phone
Day phone
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: .3
3. TYPE OFWATER SUPPLY:
Individual Well
Individual Water Storage
Community Class C Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
Community On-site
Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) ,for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid
water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water
system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's
work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I vedfythat my
investigation, based on procedures outlined In the Health Authority Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate
for the numbor of bedreooms and type of structuro indicatod herein. I further vedfy that based on the
information obtained from the Municipality of Anchorage files and from my InvestigaEon and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GAENESS ENGINEERING GROUP, Ltd.
Address 370t E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS. P.E.
Phone 337-6179
Date
Engineer's Comments:
In conducting this evaluation, GEG, Ltd. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regu/ab~ns. The reported results desonbed the performance of the
system under the conddions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational lifo of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions ore outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future perfon'nance of the system, nor do they guarantee that
there are no bidden defects or encroachments. GEG, Ltd. can therefore not provide
any warranty or fufure estimate of how long the system will continue to meet the
operational requirements of the ADEC ~r MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party ls not authorized, nor will it confer any legal tight whatsoever.
5. DSD SIGNATURE
Approved for -~ bedrooms.
Disapproved.
Conditional approval for __
Attachments:
HAA Checklist
Septic System AdvisoP/
Well Flow Adviso~
bedrooms, with the following stipulations:
Maintenan~ Agreements
Supplemental E~gineeCs Repo~
Other
Original Certificate Date:
(Rev 12~t)
Municipality of Anchorage
Development Services Department
euamng safety OMeon
On.Site warm & wastewater Program
4100 ~outh Bragaw St.
P.O. Box 19O650 Anchorage, AK gg519-6650
(9O7) 343-79O4
Legal Descdpflon:
WELL DATA
HEALTH AUTHORITY APPROVAL CHECKLIST
HIDDEN HILLS S/~ LOT 20~ BLOCK 1~ ParcellD: 011-121-45
Well type CLASS C ff A, B, or C provide PWSID~ ~
Date completed Sanita~:i=~------~ Wires properly protected (Y/N)
~l~~~sad to .ft. Casing heigM (above ground) in.
FROM WELL LOG
Data of tast
Static watar level
Well production
WATER SAMPLE RESULTS:
Collfoml '~ colonies/100 nd.
/J g.p.m.
N ta
ATINSPECTION
Other bacteria _t~ colonies/100 mi.
Arsenic: N/A mg.lL.
B. SEPTIC/HOLDING TANK DATA HOLDING TANK
Tank Type/Material :~'1 EEL
Tank size 3000 gal. Number of Compartments 2
Foundation ctaanout (Y/N) YES Depression over tank (y/N) NO
Date of pumping NEW Pumper
C. ABSORPTION FIELD DATA
Date of sample: 10/21/2005 Collected by:
OEO~ LtD.
Date installed Soil rating (g.p.d./ft~or ft~xlrm) ' System type
Length ~ .ft. Width ft.
ft.
Total depth _ ,. Eft. absorption area ,' ~ Depressi7 over field__
venation treatment (past 12 mo.) (yiN & type) NONE KNOWN If yes, give date -
Date installed 3/2-7/2005
Cleanouts (Y/N) YES
High water alarm (y/N) YES
D. UFT STATION
Data installed Size in gallons ~
"Pump on" level at In. "Pum?~~, I-ligh watar alarm level at
Datu....._..~m ~ Cydes tested Meets alarm & circuit requirements?.
E. BEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
COMMUNITY WELL
..;---- Public sewer manhole/deanout
Holding tank
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field
Water main N/A Watar service line 10'+ Surface watar.
On adjacent lots .,.----
100'+
Wells on adjacent lots 75+/100+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line Building foundation Water main ~
Water sewice line ~ Driveway, parking/vehicts storage
~ Wells on adjacent lots
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have detarmined through field inspections and
revfew of Mun~pal race.Is that the atmve systems are in
conformance with MOA HAA guidelines in effect on this date.
Engineer's Printed Name
o. ,oI
JEFFREY A, GARNF..5$
Date of Payment
Receipt Number
(Rev. 12~01 )
Waiver Fee $
Date of Payment
Receipt Number