Loading...
HomeMy WebLinkAboutHIDDEN HILLS BLK 1 LT 26Onsite File Hidden Hills Block 1 Lot 26 #011-121-51 I V A L I OF o MUNICIPALITY OF ANCHORAGE \ On -Site Water & Wastewater Program �l„ent X01' PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 \\` http://www.muni.org/onsite v 4NCH O R pG� I- Department On -Site Wastewater Disposal System Permit Permit Number: OSP201291 Effective Date: 9/11/2020 Work Type: Septic Upgrade Expiration Date: 9/11/2021 Tax Code Number: 01112151000 Site Legal Address: HIDDEN HILLS BLK 1 LT 26 G:2222 Site Mailing Address: 6320 QUIET CIR, Anchorage Owner: SLATTERY STEVENS Lot Size in Sq Ft: 15180 Design Engineer: FORGE ENGINEERING Total Bedrooms: 3 This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing freport l Provisions: A test hole is required prior to construction of the drainfield to confirm percolation rate and ion to seasonal high groundwater and impermeables. If results require a design change, construction op pending Onsite review and approval of a change order. Please submit results with the inspection or change order, if required). Received By: Date: Issued By: Date: Municipality of Anchorage_ P.O. Box 196650 a 4700 Elmore Road Anchorage, Alaska 99519-6650 ® (907) 343-7904.0 Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Section ,a. C"i I)CP,571 Cfll l'11[ x x x x VALIANCE/WAIVED REVIEW x x x x Waiver#: OSV201044 COSA#: Permit#:.OSP201291 PID#: 011-121-51 Legal Description: Hidden Hills Block 1 Lot 26 Engineer: Forge Engineering Applicant: Jason Geck & Joey Williams Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 5.0 feet. See engineer's waiver request for justifications. This waiver approval applies to the proposed absorption field only. Any fixture upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. .............................................................................. 1 Waiver is Granted: X Waiver is not Granted: Date: I 1 ��,� G Approved by: 4&M� &ZZ�y Name of Reviewer ............................................... ■ ............................. ■ 1 **** VARIAN C E/WAIVER REVIEW **** Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 011-121-51 Property owner(s) Jason Geck & Joey Williams Day phone Mailing address 1501 W. 11th Avenue, #12 Anchorage, AK99501 Site address 6320 Quiet Circle Anchorage, AK Legal description (Sub'd., Block & Lot) Hidden Hills, Block 1, Lot 26 Legal description (Township, Range & Section) Lot Size 15,180 Sq. Ft. Number of Bedrooms Three (3) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X (wiwo ADU) Septic Tank RUpgrade ❑X (D) ❑ Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Absorption Trench to Lot Line Distance: 5 I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees:' r 60 U/D -1 1 Waiver Fees: i ! D I) Date of Payment: _ �I� �% 1 9 Date of Payment: 8 19 U 0 Receipt Number: Q% 3 Receipt Number: 3 b 3 s' Permit No. 0 S P'2- 0129 Waiver No. o S V o 1 G q Permit App_.:- : .'_. c PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) August 27, 2020 MOA Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Subject: Hidden Hills, Block 1, Lot 26 - 6320 Quiet Circle Septic System Design Dear On-Site Services Engineer: The septic system on the subject lot has failed and must be replaced. We are submitting this permit application for the construction of a new septic system to serve the home. The attached site plan identifies the location of the home and the existing well along with the existing and proposed septic system. No conflicts exist between this proposed septic system and any other well or septic system on adjacent lots. The ground surface on the lot is virtually flat in the area of the new trench but slopes to the north at grades greater than 25%. The absorption trench is designed to meet the steep slope provisions of the Municipal Code. A steep slope greater than 46% is found to the east. This slope has a total elevation drop of 10’ before flattening to less than 25%. Very little migration of effluent is expected due to the porous nature of the underlying sandy soil. The existing absorption system has been in service since 1975 and no effluent has ever appeared on the surface of the slope. Surface contour lines are shown indicating direction of surface flow. Storm water flow will not impact the proposed septic system. The test hole placed on the adjacent lot in 2016 revealed no groundwater to 17’. Subsurface soils were found to be sandy gravel with a percolation rate of 5 minutes per inch. We expect similar results on this lot, but will complete a test hole prior to construction to verify our assumptions. We request a condition to the permit requiring completion of the test hole prior to construction. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201291, Rebecca Carroll, 09/11/20 The lot has very little surface area for a system upgrade due to the location of the well and the size of the lot. The new absorption trench must be placed 5’ from the west lot line. The absorption trench on the adjacent lot is more than 15’ away. Soils in the area are very clean and the absorption rate is less than 5 minutes per inch. We expect very little migration of effluent. We request a lot line waiver of 5’ to allow placement of the proposed absorption trench as shown. Wells on this and adjacent lots are shown. The new septic system will be a minimum of 100’ from the well on this lot and 100’ from all wells on adjacent lots and any surface water. Please refer to the attached plan sheet for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, P.E 9/10/20 // // //10050 0 FEET 1"=50' NOTE: SLOPES >25% WITHIN 50' OF ABSORPTION TRENCH. TRENCH IS DESIGNED TO MEET STEEP SLOPE REQUIREMENTS OF MUNICIPAL COSE. NO SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM. ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND TH-1975 HIDDEN HILLS, BLOCK 1 LOT 26 QUIET CIRCLE 8/2720 10' UTILITY EASEMENTS WOODEN FENCE TH-2016 EXISTING WELLEXISTING WELL EXISTING SEPTIC TANK. DECOMMISSION PER U.P.C. THREE BEDROOM HOUSE 1,000 GALLON SEPTIC TANK. w/20" MANWAY. EXISTING ABSORPTION TRENCH. 5' CO 2CO MH SV MT CO FCO PLACE NEW SERVICE LINE TO HOUSE. PLACE FCO. 41' LONG x 3' WIDE x 7' EFFECTIVE DEPTH ABSORPTION TRENCH. ABANDON EXISTING ABSORPTION TRENCH IN PLACE.155160165170175 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201291, Rebecca Carroll, 09/11/20 HIDDEN HILLS, BLOCK 1, LOT 26 DESIGN FACTORS: SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW PERK RATE: 6-15 MIN/IN APPLICATION RATE:.8 GPD/SF 7' DEEP TRENCH SYSTEM 1,000-GALLON SEPTIC TANK TYPICAL TRENCH SECTION (NO SCALE) 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 3' 6" 6" 3' 7' NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 10.5' BELOW GRADE FLOW LINE ELEVATION: 3.5' BELOW GRADE TOP OF TRENCH: 0.5' ABOVE GRADE 450 GPD / .8 GPD/SF /7'DEEP / 2 SIDES = 40.2 LF TRENCH REQUIRED (41 LF SPECIFIED) 8/27/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201291, Rebecca Carroll, 09/11/20 FOUND 8" REBAR E Lot 25 FOUND J" REBAR w/ YELLOW PLASTIC CAP 10' UTILITY EASEMENTS QUIET CIRCLE Lot 26 15,180 S.F. FOUND 8" REBAR w/ YELLOW PLASTIC CAP W rn v' o Lot 27 WOODEN FENCE WELL-� II" -WOODEN FENCE 43.0' FOUND J" REBAR S 89'59'30"W 92.00' T— — — — - Lot 31 Lot 30 PLOT PLAN ___ AS BUILT _X_ SCALE _1_=40_- GRID _ SW 2222Project No. 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates, inc. (907) 522-6476 Phone 000Q0p�0 (907) 522-4625 Fax Professional Land Surveyors kenOlangsurvey.com c p F q ��4 ,9 Q jonathanOlangsurvey.com O� ..S DO I hereby certify that I have surveyed the following described property: LOT 26, BLOCK 1, HIDDEN HILLS SUBDIVISION (PLAT No. 70-338) Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated this the Z__ Day of T% w ��= W a�4 __, _� _`", {�_, at Anchorage, Alaska 49TH* m KNETH. LAN •.•.o �4FRFo' ..LS -52 2.* SSG 440nRa'�FSSIONA� � 00 It Is the responsibility of the owner to determine the existence of any easements, -W"- `�O� covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963 ANCHORAGE AREA BOR ..,GH ~ ~? Department of Environmental Quality '%~-'~' 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME,, (r~ ~L&¢~-o~-c MAILING ADDRESS LOC ATI O N ~ k FL-'L:~' ~' ~J~t~~-- LEGAL DESCRIPTION SEPTIC TANK: FROM WELL MANUFACTURER INSIDE LENGTH INSIDE WIDTH MATERIAl NUMBER OF COMPARTMENTS LIQUID DEPTH LIQUID CAPACITY/d0(~ GALLONS. TILE DRAIN FIELD: O.c~-I DISTANCE FROM WELL"Y'.~'~2~,_FOUNDATION ~ ~_NEAREST LOT TOTAL LENGTH OF LINE~f NUMBER OF LINES / _ ; DISTANCE BETWEEN LINES ~ ~ TRENCH WIDTH~ IN. TOTAL EFFECTIVE ABSORPTION AREA ~/£/¢ SQ. FT. LENGTH OF EACH LINE DEP1H OF FILTER ~./~/ ~ DEPTH: TOP OF TILE TO FINIStl GRADE ~';:~ __MATERIAL BENEATH TILE IN. ABOVE TILE ____IN, WELL: TYPE. ~O BUILDING FOUNDATION CESSPOOL APPROVED - ~"¢~ _CONSTRUCTION NEAREST NEAREST SEPTIC LOT LINE SEWER LINE__ , TANK _____ OTI-IE R SOURCES DISAPPROVED __REMARKS DEPTH SEEPAGE SYSTEM DISTANCE FROM: DISTANCES: INSTALLED BY: SEWER LINE DEPTH: LOT SLOPE: (~"~.~'-k.~.~ ..... ~C¢,~7¢L. REMARKS: DIAGRAM OF SYSTEM NAME OF APPLICANT :'R ANCHORAGE: AREA BDt JGH DEPARTMENT OF ENVIRONMENTAL QUALITY( PERM/~fT NO, - 3330 "C" STREET ANCHORAGE ALASKA 99§0~ SEWAGE DISPOSAL 'SYSTEM ~ APPLICATION AND PERMIT INSTALLATION LOCATION ~ / LEGAL DESCRIPTION L.. '~ (,* THIS PERMIT T VALID WITHOUT 8OIL TEST COMPLETION DATE ANTICIPATED __ FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF' ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAl. QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION, /~'o (, ~;~, TYPEC~:" S,XE ;:':"- ' ' -- '"':'/~' TYPE'V'. FOUNDATION TO SEPTIC TANK '~ ;:'..(" ,r ,{;- ' SEPTIC TANK TO SEEPAGE Pit WALL SEPTIC TANK ~J ., SEEPAGE PIT TO NEAREST LOT LINE. DRAIN FIELD , ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK , SEEPAGE PIT DRAIN FIELD SEPTIC TANK, · '' ¢ SEEPAGE PIT , DRAIN FIELD , TO RIVER, LAKE, STREAM, CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP Of EXCAVATION S FEET INTO UNDISTURBED SOIL, 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT E,TTeD WITN aIRT,G.T REMOVABLE caps. CONEORM TO BOROUGH REGU~;ATION$ REGARDING INSTALLATION. OR CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF Create gCrga ah.uuGH O"DINANOE~O. 28-68 AND THAT THE ABOVE DESCRIBE~SYS~EM 15 IN ACCORDANCE WITH SAID CODE. top- ~soil Sp Sp The sediments were fairly were moist and com~ very patted, rlt~e contacts betweer~ sediment types were gradatioMa]~ 5 ft Sm a'b 2~0 sqft/b~m~ 5 ft Sp at 150 s2f'~/berm calculated average 200 s~t~bdrm ',~ Percco im:,~ 29 Aug 7~ F'EFd'"I I "f' 1'4(3. DEPFIF..'TMENT Ot rlEFII..'I"H FIND EN',,,' 8;?.5 "L'" 2~;TREE:T., 1::Ii'4CHORRGI!:;., FIK. RF'PI_ I C:RNT L,OCFIT I ON L. EGF:IL KFIREN NIGHT):NGFILE (..:fU I E'I-' C I l..2G .F.',:I~ HIDI]:,E:I'.4 I.{IL.I..:E; :i.';,..'L'., 4,:'1.7:.:.~: NR I GHT .'.];1" L. OT i'"lIi'.,I I MLII',I D I E:'f'FINCE BETI.,.IEEN F~ 14ELL. FINB, FII'.,I'¢ ON-E; ]: 'TE E;EI.,.IFIGE D 1%F'OSFII... tOEI FEET FOR f::i PF.:I'v'RTE [4ELL.~ OR :t. 50 TO 2E'iE"~ FEET F'ROi',I f::l i::'UBL. IC I-,.IELL. [:,EF:'ENE:,IIqC-i I. JPON THE T'¢F'E (]iF' I.,.IELL. LOGS FIRE RE6!IJ):F..:E:I)RN[:, i-,'il...I':'i!;T 8E RETLIRNE:B, TO THE DEPRRI'MEN'f' I.,.!I'I-HIN :::;E.~ I_':,l'::l"r':!~; OF THE WELL COMF'I_.ETION. [)Tt4ER [;?.E6!U I F.:Ei"IENT:.:.; I'"IFt'¢ FIPP[..*r'. 2;I:::'EE: I [::'I CRT :[ ONS F:II",I[:' CONSTRUCT I ON I.'.." I:¥,,,'1::1 ]: LI::IBLE 1'O I NSI. J[;?.[E PROPER ]: N~;'I"FIL. LRTI ON. i CERT:[F"r' THFIT t: ;t' I:;~H FRMII_.IFIF.'. FI:[TH THE REQIJIREMEN"r'.2 FO[;.'. ON--S:iI'F[.Z E.:,Et,IER~!; FIND F:'ORTEt E~,M THE MUNICIPFILI'f"¢ OF RNCHORF~GE. 2.: ]: 14ZLL. ZI'.4STFI[.I... 1'PIE S'¢STE:I,1 ZN FiCCORDFINCE HI'EH THF: COE:,[E'E;. FIF'F'I._ I CRNT 1:::I-][4. ENJ i'-.I ~: GHT IMGFILE