Loading...
HomeMy WebLinkAboutHIDDEN HILLS BLK 1 LT 29 GREATER ANCI4ORAGE AREA BOROUGH O DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO. 3330 "C" STREET ANCHORAGE:, ALAS:'(A 99503 ~ SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PHONE INSTALLATION LOCATION LEGAL DESCRIPTION ~' INSTALLATION OF: SEPTIC TANK FINANCED THROUGH SOIL TEST RESULTS ~¢~ MINIMUp¢I DISTAI~CE~. REQUIREMENTS K~UN~ATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT ___ · DRAIN FIELD WELL TO S EPTI C TA N K~-'/'~ ~'~'~ '~ / DRAIN FIELD ., DRAIN FIELD SEPTIC TANK, ~ ~ / , SEEPAGE Pl'r (o-o t CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL, 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT CONPORM TO BOROUGFI REGULATIONS REGARDING INSTALLATION. R&M ENG..,ff:ERING & GEOLOGIC . CONSULTANTS 229 EAST 51st. AVE. - P.O.,BOX 6087 - ANCHORAGE, ALASKA 99503 TELEPHONE 907--279-0483 TELEX 090-35419 Civil Engineers Geologists Land Surveyors JAMES W. ROONEY, P. E, MALCOLM A. MENZIES, P.E., L.S. JAMES H *' · V,E LLMAF/, P.E. July 31, 1973 RALPH Fi. MIGLIACClO Engineering Geologist Mr. Donald Combs 4915 West 84th Avenue Anchorage, Alaska Re: Test Hole and Soil Log Report for Sanitary System Lot 29, Block 1, Hidden Hills Subdivision Dear Mr. Combs: We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of July 31, 1973, and those procedures outlined in a letter dated September 13, 1971 by Mr. Rolf Strickland of the Greater Anchorage Area Borough Department of Environ- mental Quality. A single test hole was put do%~ within the Lot 29 area for the purpose of defining general subsurface soil conditions for the proposed sanitary system. Excavation was accomplished with a tractor-mounted backhoe and the test hole was extended ~o a total depth of 14 feet below ground surface. The final log prepared for the test hole has been included in Drawing A-01. Ground water was not encountered in the test hole. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very 'truly yours, R & M ENGINEERING & GEOLOGICAL CONSULTANTS ./,. ,I:?mes W. Rooney zc: GAAB v/~ T.H.-I 7 - ;51 - 7;5 0.0' SILT~ TRACE SAND (ML) SANDY GRAVEL TRACE SILT (SW) SILT, SOME SAND (SM) (~.0~ SANDY GRAVEL TRACE SILT (SW) SANDs TRACE SILT (SP) 9,0' I0.0' SANDY GRAVEL TRACE SILT (SW) 14.0' No Water Table T.D. Note: Test hoie excovoted with tractor mounted bacAhoe. Engineering ~ Geologic(~l Consultants Donald Combs Contrdctor LOG OF TEST HALF_ Anchordge Aldskd