HENKINS BLK 3 LT 13
MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELl_ INSPECTIQN REPORT LEGAL DESCRIPTION P,ONE / ~'NEW LOCATION I -- ~ ~ I NO. OF BEDROOMS I DISTANCE TO: M~ial ' ~ No, of compartments~ ~ Liq capacit~ n gal o~1 ....... Inside ength ' ~ ¢ O ~ Ih .uME,viAOE: Liquid depth TO, I ~ ~ ~ Manufacturer ~ Material Liquid capacity in gallons a I Well ~ ~ ~ Fnu~dati® ~ Nearest lot line . ~ t P~MIT ~. _ '., ~51 INSTANCE TO: ~ ~ ~ No. of lines / Length of each line _ f Total lengt~o~li~s/ Trench width D~s~a~"~etwee~ linesf ~E~ I ~ ~ Top of tile to finish grade . '1 Ii ' ' Material beneath tile O ~ ~ ~/ -//inches I Total effectiv~,/oo~SOrp~iont.~'~area ~ Length Width Depth PERMIT NO. ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ DISTANCE TO' Well Building foundation Nearest lot line ~ ~Class Depth Driller Distance to lot line PERMIT NO. ~ ~ Building foundation Sewer line Septic tank Absorpt on area(s) DISTANCE TO I OTHER PIPE MATERIALS P ¢c, SOl L TEST R'ATI NG zoo INSTALLER R EMA~ KS APPROVED DATE LEGAL MUNICIPALITY OF ANCHORAGE · Department <-~ Health and Environmental." "~otection · 825 ~ Street, Anchorage, AK. ~501 ~ 264-4720 ' * * * HANDWRITTEN PERMIT * * * Permit ~ ~C~-- W~ AND/OR ON-SITE SEWER PERMIT Applicant: <JOh ~,q /~OOr~=~ Mailing Address: ~)-/~ .0~ Location: '~ Phone Number: ~ V~O Legal Description: ~_ 3 ~/% ~ Lot Size: Type of Soil Absorption System Is: Trench: Drainfield: Seepage Be~: ~'~ Holding Tank: MaxJn~um NtLmber of Bedrooms: \? Soil Rating(sq.ft/br) The Required Size of the Soil Absorption System Is:' DEPTH ~'~ .LENGTH %0 ~ AO GRAVEL DEPTH ~ '' ~o~- WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). · * REQUIRED SEPTIC(HOLDING) TANK SIZE = /(~--)~ GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. · * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is !00 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a conumunity sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. · * * PERMIT EXPIRES DECEMBER 31, 1 9 8 2 * * * I certify that: (!) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to inclUde more that 3 bedrooms. Signe~:~~~ Issued by: ~?"/~/~~~ Applicant Date: ~ · SWP/024(1/81) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG- PERCOLATION TEST SOILS LOG / TCO'AT,O. LEGAL DESCRIPTION: -- .$r~-OL - S['['IL~ ,.~'~5 SLOPE 1 2 6 7 8. 9 10 11 12 13 14 15 16 17 18, 19- 20- WAS GROUND WATER ENCOUNTERED? P IF YES, AT WHAT j~ / DEPTH? 5'/2" SITE PLAN Gross Net Depth to Net Reading Date Time 'rime Water Drop -H-~zD 5~ 5'-F:,' :5o --~ . . PERCOLATION RATE /~t~* (:~ (minutes/inch) TEST RUN BETWEEN ~ FT AND "~:;~ FT ~f'~ ~ ~-~"-""~1"'-' ~'~.,~"~ ~::~:)~ CERTIFIED BY: // DATE: Permit ~~ Applicant: ~iC 1~1 Location: Legal Description: MUNICIPALITY OF ANCHORAGE Department/ ~ Health and Environmenta?-'?rotection 825 Street, Anchorage, AK. ~9501 264-4720 * * * HANDWRITTEN PERMIT * * * WELL A ...... ~ .... " PERMIT ~90©¢~-~ Mailing Address: ~~ Phone Number: D ? ~O ~1 f~f] ~,~ m ~ LOt Size: Type of Soil Absorption System Is: Trench: Drainfield: Maximum Nun~ber of Bedrooms: Seepage Bed: Holding Tank: Soil Rating(sq.ft/br) The Required Size of the Soil Absorption System Is:' DEPTH .... .LENGTH '~-" GRAVEL DEPTH ..... ' WIDTH " The length dimension is the length(in feet) of the trench' or drainfield. The depth of a trench or pit is the distance between the surface of the ground and t~e bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK :SIZE = GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper, installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 $ 2 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more that 3,bedrooms. S igr~e~ ~&~ ~/-~ ~/~}/~Issued by: ~ ~~ ~ Applicant %/__3~ //~ 2- ~/ Date: . . SWP/024 (1/81) (9O7) 243-2282 KEN JOHNSON KEN S COMPANY WATER WELL DRILLING PUMP SALES & SERVICE 30 YEARS ALASKA DRILLING 3163 LINDEN DRIVE ANCHORAGE, ALASKA 99502 August 21, 1982 John ~oore P,0. Box 4-604 Anchorage, Alaska RE, Lot 13 Blk 3 Henkins Subd. 0 ft to 2 ft 2 ft to 15 ft 15 ft to 25 ft 25 ft to 29 ft 29 ft to 36 ft 36 ft to 41-6 ft 41-6 to 43-6 ft 41-6 43-6 to47 ft 47 ft to 50 ft MUNICIPALITY OF ANCHORAGE DFPT OF [': 'I.T., ,ct: ENVIRO1,14', ~i', ;,'~ ..... O, ~',--I'ION WATER WELL LOG Fill Organic Peat Blk silt trace of gray RECEIVED Blk sand..trace of grav..weeps H2o Sand &grav Water bearing 2 GP~I ..12 ft head Fractured rock ( dry ) Weep in over nite to 3 ft TOC.. 1 GPM Casing refusal firm rock ( dry ) 2.43 GP[~ H2oo. Static WL 2°5 ft TOC ~ APPLI¢:'~NT FILLS OUT UPPER HAI:'" ONLY .. Typ~ of Resi~nce ~Single Family ~ ~ Multiple Family No. of Bedroo~ ~ ~ Other Water Supply Individual ~ I~ A~ACH WELL LOG. A w~l log is required for all wells drilled since June 1975. ~LJ~, uJ~[ For wells drilled prior to that date, give well depth (attach log if available). Community ~ Public Utility Sewer Disposal ~ Individual ~ ~ ~'~-~ ~ ~ Year Indiv~ual Installed: /~ ~ Public ~ility When Connected to Public Utility: ~" ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE.EST BEFORE ~OCESSING CAN BE INITIATED. Time Time Time \ / Time Dste Date Date k/ Dste \/ Inspector Inspector Inspecto~ Inspect~ Field Notes: /~_.~Co~-O %~ ~ ~ <~ _ ~ %~0~ MUNICIPALI~ OF ANCHORAGE ' DFDT C RECEIVED (~) APPROVED BEDROOMS ~ *CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL* Soils batin~ Date ~wer Installed Well To Abeorption Ares WeII Lo~ beceived /'~'~ ~ ~ ~- Well tO Tank Septic T~k Size CONSULTING ENGINEER 203 W. 15th AVE "C" SUITE 203 ANCHORAGE, ALASKA 99501 TELEPHONE: (907) 279-3916 TO WHOM IT MAY CONCERN: SEWER AND WATER INSPECTION Lot 13,.Block 3, Henkins Subdivision John Moore On Friday December 3, 1982, the installation at this property was inspected. The stand- pipes for the sewer system were in place and capped. The well casing had a .sanitary seal and the electrical wires were in conduit. The distance between the well and the septic system was measured and fo.und to be 100 feet. A water sample was collected on December 6 and delivered to the Chem Lab. HENKINS SUBDIVISION . lO/9/85 Keith Bandt Platted: Zoned: Lot Description: P robl ems: Probable Causes: End Effect: September 13, 1955 (Plat #387) R6 in 1982. Previously, it was zoned. UNRESTRICTED 61 lots and 3 tracts. Majority of the lots are 20,000 s.f. One of the affected lots is only 14,365 s.f. Water table has increased in recent years causing systems to fail and sewage to leak onto the ground surface. Lots most affected are cross-hatched on Figure 1. Based on soil tests conducted in 1982 on several of these lots, water levels have increased 4-6 feet. System failure in this case can contaminate the shallow water table, and the potential exists for contaminating the deeper drinking water aquifers although no problems have surfaced to date. Due 1. e 0 to a combination of 3 factors; Natural phenomena - A natural increase in the water table due to changes in the hydrologic cycle. There is historic evidence that the area affected was very wet, saturated by ground water, prior to development. There are presently many indications of saturated soil as evidenced by small streams, springs, and weeps within the affected area. Monitoring well data helped establish the boundaries of the affected area. A stream diversion around lots 8,9, and 10 may be a factor in fixing the water table elevation on Lot 15, Block 3, although the degree of impact is difficult to assess and is not the sole factor. Wastewater loading from septic systems probably aggravates the situation by contributing to the water table rise. Lots 12-15, Block 3 and Lots 5-6, Block 4 will be required to abandon their existing systems and hook up to a holding tank or package treatment plant (innovative) by November 1, 1985. Lots 3-4, Block 4 will be required to raise the absorption field to meet the proper separation distance to ground water. Curtain drain systems are not viable and have been excluded as an option. High fecal coliform levels found in a monitoring well on Lot. 3, Block 5 are currently being, investigated. The water supply well for this lot is in close proximity and is only drilled to a depth of 44 feet with a static water level of 6 feet from the ground surface.