400%
200%
100%
75%
50%
25%
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
HENKINS BLK 4 LT 1
Rick Mystrom, Mayor Mun apaHW of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 March 3, 1997 Marie Antoinette Phillips PO Box 770696 Eagle River, Alaska 99577 0696 Subject: Lot 1 Block 4 Henkins Subdivision Permit #SW960027, PID #051-291-06 The subject permit, issued February 23, 1996 by this office for a single family well and/or on-site wastewater system, has expired as of February 23, 1997. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. Ail inspection reports must be submitted within 30 days of construction completion. Wqqen applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. Sincerely, Jam~s Cross, P.E. Pro~ram Manager On-site Services enc: Copy of Permit cc: S & S Engineering MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW960027 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:PHILLIPS MARIE ANTOINETTE OWNER ADDRESS:19944 HENKINS RD EAGLE RIVER, ALASKA 99577 PARCEL ID:05129106 LEGAL DESCRIPTION: HENKINS BLK 4 LT PAGE 1 OF 1 LOT SIZE: 20038 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: DATE ISSUED: 2/23/96 EXPIRATION DATE: 2/23/97 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. ?SPECIAL PROVISIONS TH~ S~ND ~EQ~ INr, ~E FILTER LAYER NUST BE A CLEAN COURSE/ /~"~I~H ~%~,~~[~I,~G ~HE ~100 SIEVE AND 2% OR LESS: PASSING THE-~'20~ 'SI~E. ~ 'SIEVE ANALYSIS ~ST BE PROVIDED ~ THE S~D USED OR OBTAINED FROM AN ~~~y~ BY: ISSUED BY: ~/~ ~~ DATE: ROBERT C. COWAN, P.E. ROBERTA. SHAFER, P.E. January 26, 1996 CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 HEALTH AUTHORITY APPROVALS SEWER &WATER MAIN EXTENSIONS SEWER &WATER INSPECTION ENGINEERING STUDIES ANDREPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOILTEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS ONSITE WASTEtNATER DISPOSALSYSTEM DESIGN MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 1, Block 4, Henkins Subdivision Request you issue a permit to upgrade the septic system serving the existing four bedroom house on the referenced property. A test hole was excavated and ground water monitoring will be performed in the spring. The approximate location of the test hole is located on the attached site plan. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. If you require additional information, please contact us. Sincerely, cc/g Enclosure 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 " I I 1" = 40' DESIGN SITE PLAN ----~-^~ ~ ~00~ ~o~ ~ ~__ ~ __~ [.r o ~ II Ne8 0 t,L~ -~l N Z ~ ~ ~ ~ ~mO -- 0 ~m~ ~ ~ - ~Fz 5~ > >,,,~ ~ ~ ,,Sx , ~=_ o EXISTING z o 4 BDRM HOUSE .-'~,i-.~ On 00O0O4 ' m zN b~b, L~ =--m~ om < o o~ < O00 F-- GARAGE DIVISION STREET o~>/ o m:~ 0 © DETAIL PROFILE N:f.S. J ~OALE F1 00~ ~oc~ r~j 0 Om zm..~ :;gm (DOC) m~m · -F "~ iI ~ C) ~. ~ t~ PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: '~' 0 ~- ~ DATE PERFORMED: "'~Ar,'~' ~' ~"~ Township, Range, 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16- 17 18 19- 20- COMMENTS ~.O.H. 'too ..Rocky Zw SLOPE SITE PLAN WASGROUND WATER ENCOUNTERED? S L IF YES. AT WHAT ~ O DEPTH? p E Depth Io Waler After Moniloring? '~ Gross Net Depth to Net Reading Date Time Time Water Drop < I PERCOLATION RATE __ tminules/inch) PERC HOLE DIAMETER =PE'S"T-~..U.~; ~ETWEEN ~- ']g- FT AND .~ F5 PERFORMED BY17c,$4 F, ag;= ~.;ver Loop ~oa~J No. ';'04 I . CER]IFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE F,~tl~L¥~^N~k~ ~arul~PAL GU~DEUNES m EEFEOT ON TH~S DATE. DATE: __~' /--/ / ~7 ~ ROBERTC. COWAN, P.E. ROBERTA. SHAFER, P.E. HEALTH AUTHORITY APPROVALS SEWER & WATER MAIN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE pLANS ROAD DESIGN SOILTEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE WASTEWATER DISPOSAL SYSTEM DESIGN ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 REFERENCEs Lot 1, Block 4, Henkins Subdivision January 26, 1996 GENERAL: 1. Se The scope of this project includes the installation of a 1500 gallon wast·water S.T.E.P. system (septic tank) and a pressurized absorption bed to serve the four bedroom residence located on the referenced property. The existing leachfield is to be abandoned completely. Construction shall be in accordance with the approved site plan and design drawings; Municipal permit with any special provisions or conditions; and all applicable State and Municipal Wast·water Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 Page Two Lot 1, Block 4, Henkins Subdivision January 26, 1996 e e e The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Ail standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Septic tanks installed With less than 4 ft. of cover shall be insulated. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. LEACHFIELD BED INSTALLATION: Excavate the proposed Bed Area to the depth shown on the design. The bottom of the excavation shall be within 2 inches of level. If the bottom of the excavation becomes smeared, it must be raked or scratched (ruffed-up) before gravel or sand placement. e If a sand layer is required, place sand over entire excavation to the required depth shown on the design. The top of the sand layer must be within 2 inches of level. Se Sewer rock shall be placed uniformly throughout the entire bed. The distribution piping is to be of PVC (ASTM D3034 or equal). All joints are to be solvent cemented. Gravel depth below the distribution pipes shall be a minimum of six (6) inches. Gravel depth above the perforated pipe shall be a minimum of two (2) inches. o The distribution piping must be as shown on the design. The distance between the outermost perforated distribution pipes and the sidewall of the absorption bed must be no more than three feet. Page Three Lot 1, Block 4, Henkins Subdivision January 26, 1996 Se St Silt barrier material must be installed between the final gravel layer and the native soil backfill, unless insulation is used, then the silt barrier should be installed over the insulation. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed at the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel depth shall be perforated six (6) inches below the bottom of the horizontal distribution lines. The monitoring tube should not extend below the bottom of the gravel surface. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finished grade over the bed must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. e The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Cast Iron ASTM D3034 (PVC) ASTM F810 (HDPE) ASTM D2662 (ABS) Perforated Solid Yes Yes Yes Yes Yes No Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). Page Four Lot 1, Block 4, Henkins Subdivision January 26, 1996 6e 7e A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the ~200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. e The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. Page Five Lot 1, Block 4, Henkins Subdivision January 26, 1996 The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR 'INSTALLER EASEMENT AGREEMENT The undersigned, in consideration of mutual agreement set forth below, grant, convey and affirm the following easement, effective this 13 day of Februarq 1996, and agree to the conditions and r~strictions as follows:ii I, Marie Antoinette Phillips, hereinafter referred to as grantors, owner of certa~ r~2. property herein after referred to as "Lot 1; Block 2; Henk~mi Subdivision". According to the official plat thereof filed in the records ANCHORAGE RECORDING DISTRICT, Third Judio..~al Dis~,~et, State of Alaska, doi hereby grant to Marie Antoinette Phillips, hereinafter referred to as thei Irantee, as owner of certain r~ property hereinafter referred to as "Lot 2;! ~lock 2; Henkins Subdivision" according to the official plat thereof filed in ~he records of ANCHORAGE RECORDING DISTRICT, Third Judicial District, State of ~la~ ka, ~n easement for an o~-site ~stewater disposal system to be placed on Lot 2; ~lock 2; Henki~ Subdivision, together with right to maintain the on-sita ~astewater disposal system to include reasonable egress and ingress for pumping the septic tank and maintenance of the absorption area. The easement to be! effective upon the signing of this agreement by the parties. It is understood and agreed that s~wer service to Lot I; Block 2; Henki~ Subdivision is to be provided by connection beginning on Lot 1 and extending onto Lot 2; Block 2. It is further agreed that the cost of maintenance of the in place s~wer lines shall be born by the grantee. There shall be no charge for the use of the on-site wast~water disposal fa~lities so long as this easement is in affect unless a charge is arranged between the parties of their heirs or assigns or successo~ in interest by separate w~itten agreement. Be Grantor makes no warranty as to the adequacy of thc wastewater disposal~ S~?Stem and shaY.~ not be L~abl~ for any damag~ caused by the system failing to work adequatgly. Grantor: The grantor further covenant and agrees that the grantee shall have! full, free and uninterrupted use of said gasement for reasonable! domestic use as long as such use do~s not ~eate an unreasonable, adverse impact upon the grantor. Faille to make use of the on-site wastewatgr disposal system herein described shall not be deemed abandonment of the said easement. The grantee further agre~ to §~ar all cost, if any, for the operation, maintenanc~ and/or abandonment of the on-site waste~ater disposal system and/or gasement. This eas~o~ent from grantor to grantee sh~ be binding upon the inure to the benefit o f the part~s hgrgto, their heirs, legal l representative, successors and assigns, and shall run with the land. ,~ARIE ANTOINETTE PHILLIPS ~Lot ii Grantee: MARIE ANTOINETTE PHILLIPS (Lot Subscribed and sworn to before me t h~/~day of ~>~.~" 1996 for Marie ~ntoinette Philips Mg commission gxpir~ /~/~ No~y Pubic