ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP211076 PID Number: 015-221-25
Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade
Name
HEATHER & DEREK BASCOM
ABSORPTION FIELD - ADVANTEX
® Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
12300 HERITAGE ROAD, ANCHORAGE
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
4
1 GPD/SF
10 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3 Ft.
Gravel depth beneath pipe
7 Ft.
Subdivision Block Lot
HERITAGE HILLS 4 3
Fill added above original grade
VARIES 0.92-1.83 +/- Ft.
Gravel length
43 Ft.
Township Range Section
Gravel width
2 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
602 Ft2
1
Ft.
Well
1 50'+
50'+
25'+
TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ® Other ADVANTEX
Manufacturer
ORENCO / ANCH. TANK
Capacity
1500 Gal.
Surface Water
50'+
50'+
Material
STEEL
Number of compartments
2
Lot Line
10'+
10'+
NA
Foundation
10'+
10'+
LIFT STATION
Manufacturer
ORENCO
Capacity
1500 Gal.
Remarks Deck support driven to bottom of tank elev.
Alarm location
BASEMENT
Electrical installed by
PLC ELECTRIC
Tank
PIPE MATERIAL House to tank 3034 dra of elo 3034
Installer NORTHERN EXCAVATION
Drainfield 3034 CO/MT 3034
Inspector FWC
BENCH MARK (Assumed elevation) 100 ft
Inspection 1s` 4/15/2021 4/16/2021
Location and description
2�d
3`d 4/16/2021 4'" 4/19/2021
IBOTTOM OF SIDING
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
.-
Conditional Approval: Date
�•••*.
40
TH
.... ..........
Curtis Huffman
�FCaE 1289911
Septic System•
Approved -
Date
.��0'�
Note: this approval does not Include well permit requirements.
tKev uwuz/iu/
PERMIT: OSP211076 PID: 015-221-25
/STAKED 50' WELL
RADIUS & PL
PRIOR TO CONST.
VACANT
30'
LOT 4
WELL
®
S89 59'00"E
150.00'
TH21-1
100• WELL
DECOMMISSIONED RADIUS
15.3' SHED EXISTING TANKS.
x
GREEN o
LB
INSTALLED DECK
SUPPORT PER
LOT 3
HOU MT I
CODE & AX -20
BILK 4
(n
C 0
1500 -GAL 4 -BR
Cf) _
O
/ SYSTEM
O m
O
r
DCO
O '0
O
<
/ F MH
22.1'
O D
WELL
p
O
H
DIV
24.0
G POD BM
E MH
O G')50
O m
RADIUS
5. D DCO 41
x
I
rr1
x
O
D
LOT
6 I
X
COCMT J
o=
0
0
D
EXIST.
CRIB
FCO C Z
v Cf)
�x
m m
O
O
O
p
EXISTING TRENCH
t--2jjO',
24.03
Ox
p
G VEL
O
I
o CARPORT D
x
LOCATED WATER LINE
22.0
x
APPROX.
—X—X—X—X—
S89 59'00"E
150.00'
100' WELL LOT
2
RADIUS
A -C=21.7'
DCO DIV
CO MT CO MT
B - C = 3 7.5'
FCO DCO 96.69 96.73
R PH MH AX20 POD MH
91.96 FINAL GRADE
92.87 TH21-1
A - D = 2 2.7'
FILTER FABRIC
9104
RADE ORG/01-
2.5' ORIGINAL GRADE/—
B -D=33.5'
�
A -E=21.00
SM -ML
3.68
a.oa 88.04/GM
B - E = 3 0.8'
91.61 1500 -GAL
STEEL
SEWER ROCK
81.04 81.04
NO GRND.
A - F =19.0'
ADTANK X
4%15/21
B -F=26,0'
6•
A -G=28.7'
sw
1s'
B -G=212'
SEPTIC SECTION
7204 B0H
A -H=34.1'
SCALE: NTS
B -H=21.0'
6
.6
A -I=60,'
HERITAGE HILLS BLOCK 4, LOT
3 SUPPORT$SERVICES:
\j\\
B -I
A -J=86 3'
PREPARED FOR:
F
`"�s1
B -J=54.6'
HEATHER & DEREK BASCOM
6��
�� 1�
12300 HERITAGE ROAD
ANCHORAGE, AK 99516
� �
* 9 TH
`
Huffman
FIRST WATER CONSULTING
DATE:
4/19/2021
rtis wx
13030 Sues
Way
SURVEY:
JLS
1 CE 128991
Anchorage, Alaska 99516
DRAWN:
FWCS
��w
t 4/19/2021 ear
(907)350-9566
SCALE:
1" = 30'
\ P'FESSIO��y "w
FirstWaterAK®gmail.com\`��
4661
13030 Sues Way - Anchorage, Alaska 99516
Tel. 907-350-9566 FirstWaterAK@gmail.com
SOILS LOG / PERCOLATION TEST
LEGAL DESCRIPTION: HERITAGE HILLS B4 L3
PERFORMED BY: FWCS / FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT
ON THIS DATE. DATE: 4/15/2021
DEPTH
FEET
OG
SOILS
1
ORG/OL
2
3
4
SM/ML - GM
5
6
7
8
9
10
11
12
13
14
15
16
17
SW
18
19
20
BOH
Reading Date Gross
Time
Net Time Depth to
Water
Net Drop
4/7/21 30 min 6” 1 11/16”
30 min 6” 1 12/16”
30 min 6” 1 11/16”
PERCOLATION RATE 18 (MIN / INCH)
TEST RUN BEWTWEEN 6 & 7 FT
PERC HOLE DIAMETER 6”
PRE-SOAKED PRIOR TO TEST & ALL READINGS TO
THE 1/16TH.
1
GROUND WATER ENCOUNTERED: NO
IF YES, AT WHAT DEPTH: NA
DEPTH TO WATER AT MONITORING: DRY
DATE: 4/15/2021
TESTHOLE # 21-1 DATE PERFORMED: 4/6/2021
2
SEE SITE PLAN FOR SLOPE & LOCATION
COMMENTS:
VERIFY GROUNDWATER MT
AT TIME OF CONSTRUCTION
PERFORMED FOR: HEATHER & DEREK BASCOM
4/15/21
S
LOT 4
30' I 30'
589'59'00"E 150.00'
SHED
L-
WELLLL
y 20.0'
U} M
CD0
MH 22.1' a
24.0' m
LOT 3 MH z o
8LK 4
.� M g
SEPTIC ■ n a _ a
VENT =M Z _
(typ) d
m a
n Q
24.0' 1.3' d
GRAVEL
^' CARPORT O/W
0
220' m
m
_ _—x—x,x—x-
589'59' 00"E 150.00'
LOT 2
ANCHORAGE RECORDING DISTRICT, ALASKA
AS -BUILT OF:
HERITAGE HILLS SUBDIVISION
LOT 3 BLOCK 4 PLAT 63-411
SURVEY CERTIFICATE: 1, John L. Schuller, Have conducted a = 0 F AZ ',y
physical survey of this property as shown on this drawing and that the / �}
improvements situated hereon are within the property lines and no -0
enciuoachmen[s exist other than Hated. Under no circumstance should , * 49T
any information on this drawing be used for construction of fences,
structures, improvements, or for establishing boundary lines. L
EXCLUSION NOTES: It is the owners responsibility to detennine ? •70' • : • ' .. • • ............. • .. • ..
m
the existence of any easements, covenants, Or restrictions which p� OHN L. SCHULLER.: 0�n
do not appear on the recorded subdivision plat. #��e, LS -10408
WORT( ORDER NUMBER: DAM SCALE E-MAIL.
21-22-2
APR W wOrHZEaom1e GFW Nume t echullera� nAe�t ,r ro f e s s ionO ;wV'r
JLS SW2737 210136B
v Q r
�1831 Talkeetna Street
Anchorage, Alaska 995DB
(907) 227-1455 office
(907) 274-4992 fax
d11U MICIPAUTY OF ANCHORAGE
On -Site Water & Wastewater PrN rare
PD Box 19685[} 4700 Fimera RCsad
AWhewago. AJes#e 9951.9-6650 Phone, (907) 343-7904 Fax• (9oF) 3.43.7997
hrtp:fAvw u.mUni.arg,R tMit$
On -Site Wa stewater Disposal y -stem Permit
P&WI NuAili n uSN21 1Vb
Werk Ty": .^tiApfin I 1p9hwrin
Tax Code hlurnW: 0152PI2
Silo L4mal Ad € ma*: H ER ITAGE HIL LS t3 LK 4 LT 3 G-2737
5ffe Mallimg Address: 12300 HERITAGE RD, Anchorage
ORYFw: BASCOM HEATHER A & DEREK
Design Englne r: FIRST WATER CONSULTING
This permit is for the construction of,
E1lective bad:
FYrlir#inn 13AM
Lot SIze In ! q Ft;
Total Etedrooma.
Jl�02 1
15500
m Disposal F1iAd 0 Septic Tank ❑ Holding Tank ❑ Prim ❑ P"Vats Well ❑ Waler Storage
AIS construclion shall bH in acrordan with;
1. The attached approaed design.
2. All requirements specllied in Anchorage Monicipal cads Chapters 16,55 and 1E.65 and the Stale -of Alaska
Waslewalei Disposal Reg til alions (18AAC72) and DOnking Vater RequlMons (i6AACB0)
3. The wastewater code requims inspections during the installation. The anglneer shall noi4y the Development
Services Deperlment per AMC 15-65- Provide noiilir-tion by suing (907) 343-79D4 (2417).
4. From October 15 to April 15, a sutmirface s6i6absoWlon system under ootlatruotiofk during Ireezing w$a#har
Shall be ailhar:
a. Opened and Closed on the same day. or
b. Covered- sealed, .and hea#ed to pravont Ireetting
Special Provisions:
4
1. A la$I hole shall be completed prior to oons1ruction 0I 1h$ absorpdon held to verily mperation lo impenYmables
and ReacoW)l high groundwater, as wr.11 a3 penzAiIAtiu , idle. If resulih. iequlit! a desgn cnijrlgo, iorls#uirtion shall
Shap pend ing Onsite fewiew and approval of a cha nge n rder. Please sii bMe resu Ns with the inspection report (or
change Order, if raqulfed�.
2. The water service lino shall be Id led prior to conslllUcfion ire ardor to verity a mi ni rnu m 10 tt sepatation to
Septic tank end abscrpiian liekls.
S. Supports IN decks or stslrs over 30" high shall 130 5 0 from tho seplle lank or driven doep enough so thal the
lank is OuI840 the soil bearing prism of the support.
Raceivod By:
Issued By:6�1 ry i A &.P&7
312612021
Dale;
Dale,/�0.21
x
13021 Montego Circle, Anchorage, AK 99516
907-350-9566 / FirstWaterAK@gmail.com
March 19, 2021
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: SEPTIC SYSTEM UPGRADE PERMIT
LEGAL: HERITAGE HILLS BLOCK 4, LOT 3
The owner has requested that we upgrade the aged septic system on the above referenced lot. We propose
to install one deep trench with and Advantex system to serve the existing 4-bedroom residence. The design
is conservatively based on area soils and groundwater found within MOA record documents. A confirming
testhole will be completed prior to construction. The slopes are moderate at 3-7% at the proposed upgrade
location.
The lot and the adjacent 5 lots are served by a water well located on Heritage Hills Block 4, Lot 8. Per the
file Heritage Hills Water System file located in the MOA on-site database, this well was approved by ADEC
in 1973 to serve 6 lots (Lots 1, 2, 3, 6, 7 and 8 of Block 4). For the most part per the record docs, the well
has been classified and treated as a Class C well, but also noted as a Class A on some other occurrences.
Although currently Class C wells are considered private shared wells, the most recent designations have
been as a Class C per waivers granted by Bill Reith, P.E. of the ADEC in 2009 for a conventional septic
upgrade on Lot 1 and for a tank on Lot 8. A 2017 MOA approved and installed septic upgrade on Lot 7
shows this well as a private shared Class C well.
In any case and to mitig ate any impact to this well and any other wells of the area, an advanced wastewater
system is to be installed. The source water of these wells is further protected by the area;s silty and clay
soils. Nitrate levels appear to be low for the area. Water samples have been taken, but are pending final
analysis. This design will improve the current condition of the on-site septic that has been in operation for
several decades. The proposed design will not impact any of the neighboring properties. Please contact us
if you have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211076, Rebecca Carroll, 03/26/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211076, Rebecca Carroll, 03/26/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211076, Rebecca Carroll, 03/26/21
�InwL. GREk, rER ANCHORAGE AREA Nt,-, UGH
ti�liILJiI\ I��
Department of Environmental Quality
" - 3330 C Streets>,%'
alAnchorage, Alaska 99503
INSPECTION REPORT ON-SITE S%EWAGEp�DISPOSAL SY SEM
G MAILING ADDRESS! �y - "��' PHONE
NAME
LOCATIONpLEGAL DESCRIPTION
u
SEPTIC TANK:
DISTANCE (/� �q NUMBER OF
FROM WELL 214f'ANUFACTURER/MATERIAL COMPARTMENTS
INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY©CGALLONS.
TILE DRAIN FIELD: _ TOTAL LENGTH/
DISTANCE FROM WELL�FOUNDATION NEAREST LOT LINE �` OF LINES
NUMBER OF LINES- DISTANCE BETWEEN LINES TRENCH WIDTHIXL IN. TOTAL EFFECTIVE
ABSORPTION AREA 10995�6 - SQ. FT. LENGTH OF EACH LINE /
4 1V DEPTH OF FILTER /
DEPTH: TOP OF TILE TO FINISH GRADE._ MATERIAL BENEATH TILE 'Kt.ABOVE TILE IN.
WELL:
TYPE- ) �0k CONSTRUCTION DEPTH DISTANCE FROM:
BUILDING NEAREST NEAREST SEPTIC SEEPAGE
FOUNDATION LOT LINE , SEWER LINE , TANK , SYSTEM
CESSPOOL OTHER SOURCES
APPROVED DISAPPROVED REMARKS --'
DIAGRAM OF SYSTEM
DISTANCES:
INSTALLED BY:
SEWER LINE DEPTH:
PIPE MATERIAL:-�-`
LOT SLOPE: d
REMARKS:
Form EQ -032
ld. H.H.13.
T�P� 8F SOl| �BSORRTT0N SYSTEH IS� TRFNCH
MAXJM|/H Ni|HRFR OF BEDRO0M5 � 4 SOIL RHTING (SQ FT/RR)= 250
THF RFQUTRF/! SIZE OF THE S0Ii. R8SORPTiON �YSTE� lS�
����U�
������
�~���
�����
���
_~_
H PHCKHGE
P�HNT MHY RE �NSTHL|'ED
HT THE
PERMITTEE/S
OPTION SURJECT TO THE
F0U-0WI1 j
C0NDIT70N��
IINSF HPPROVEV
PLHNT
MH� BE INSTHLLED
1 FITH�R
� CLHSS I
OR
? 4
CO�TTN||0U� M�INTENHNCF
AG�EEMENT
I�
REQUIRED
IF 8 MHTHTENHNCE
HG�FFMFNl
TS NOT
KFPT C||RRFNT YO|i
MHY
RE REQUIRED
TO ENLHRGE THE �OIi
�R�U�pTI0�
��........ ........ �����
SYSTFH
.... ...... �......
HND/0R YGU MHY
... ��..... ���
RE
....
�URJECT
���
....
TO PROSECUT}ON
��... ...... '����������..... ....
������'�����;�
����
it IT
0F rYSTFM
WlTHOUT F�NHL
INSPECTION
HND HPPROVHL BY THlS
��CKF7LLING
i:,NY
DEPHRTMENT
WILL BE SURJECT
TO PROSECUTI8N
MTN7MUH D
EFN
H WEL| HND HNY
0N
-SITE
SEWHGF
D7SPOSHL SYSTEM IS
100 FFFT
F0R H PR7�HTE WFU.
OR ?00 FEET
FOR
H
PUBLIC
WELL
�THFR RFQ|�IRFMENTS
MHY pi
1-:w �PFCIFICHTI0NS
HND
CO��TRUCTION DI�GRHMS HRE
��H{|ARiE
TO IN�|!RF PROPFR
lNSTHL|HTlON
E:::��������!I�
] CFRT�F;
THAT
;� ; H|; FHMTL7HR
WTTH THF
RFQUIRF�ENTS
�U�
�N~�ITE
SEWERS HND WBJ.S HS SET
�RRTH 9�
THF M|iNIC7PHLTTY
OF HNCHORHGE
?T WIL|
IN�THLL THE SY�TFM
lN HCCORDRNCE
WITH
THE
CODES
:u�c/�c c�u�p�NLHRGEMEFYT
IF THE
GRE.; `K ANLMVKAUC MIXEM our V11
Department of Environmental Quality
03500 Tudor Road
Anchorage, Alaska 99507
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME��,,''�� �7%12/r(' MAILING ADDRESS %�(k
% ?X'- 6('I(Y l'l9L�N %�%��'� PHONE
GW lr
LOCATION �`d�(r�//�/+�`'� �� LEGAL DESCRIPTION !b% 7 L `
SEPTIC TANK:
NUMBER OF
DISTANCE rr,' I
FROM WELL AJ _f MANUFACTURER `� 160K \c fUA 0 , MATE RIAL�S-kU (liar 1% `/ COMPARTMENTS
INSIDE LENGTH INSIDE WIDTH — LIQUID DEPTH LIQUID CAPACITY L GALLONS.
SEEPAGE PIT: hh/
NUMBER OF PITS �. DIAMETER --OR WIDTH AL , LENGTHS,,, DEPTH
LINING MATERIAL - Ca CRIB SIZE: DIAMETERcy'Y1 DEPTH DISTANCE FROM: WELL 1ZO/
TOTAL EFFECTIVE
BUILDING FOUNDATION 3� NEAREST LOT LINE f' Via• ABSORPTION AREA (WALL AREA) 6'r SQ. FT.
ADDITIONAL ABSORPTION
WELL:
TYPEc�'Jn' -1) JIL- CONSTRUCTION I /Lli D 6 ��/'�`l DEPTH ?� - DISTANCE FROM:
BUILDING NEAREST NEAREST SEPTIC SEEPAGE
FOUNDATION ��� J LOT LINE, SEWER LINE S ( TANK �� SYSTEM � '-
CESSPOOL 1(/4y16' OTHER SOURCES
APPROVED DISAPPROVED REMARKS
DISTANCES:
INSTALLED BY:
PIPE MATERIAL: aLL &egi' /F'A'A'
LOT SLOPE:
REMARKS: —
Form PW -026
DIAGRAM OF SYSTEM
YJ
P
� I C=U1C
l'un�iRur_tia,li l
naTF &i -d. 716172 APPROVED
G.A.A.B.
Al
0 1 1 11 1 111; INS MAIN I
Development Services Department
On -Site Water & Wastewater Section
Parcel I.D. 015-221-25
C: ,4 4�
Phone: 907-343-7904
Fax: 907-343-7997
Certificate of On -Site Systems Approval
1. GENERAL INFORMATION
Complete legal description
Expiration Date: Q 0 c2O Q
E HILLS BLOCK 4, LOT 3
Location (site address) 12300 HERITAGE ROAD, ANCHORAGE, AK 9951
Current property owner(s) HEATHER & DEREK BASCOM Day phone
Mailing address 12300 HERITAGE ROAD, ANCHORAGE, AK 99516
Real estate agent
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
4
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
❑
Private Septic
Water Storage
❑
Holding Tank
❑
Community Well
®
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by:
COSA to be released to the engineer, unless otherwise requested by the engineer.
Date:
COSA Fee $ Waiver Fee $
Date of Payment y o� ,W f Date of Payment
Receipt Number �D�1l5 3 Receipt Number
COSA # 0 5 C � 1 � � � "I Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Address 13030 SUES WAY ANCHORAGE AK 99516
Engineer's Printed Name CURTIS HUFFMAN PE Date 4/17/2021
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the .�
well and septic system. Therefore, any estimate of how long a system will function satisfactory ���:' • ` ����
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting & FWCS ''. TH .......
6. DSD SIGNATURECurtis Huffman
J System #1 Approved for bedrooms ¢c/sT , CE 12$991 .-\§ �dW'�
System #2 Approved for bedrooms
pROF SS NP��-m,'.�
Disapproved
Conditional approval for bedrooms, with the following stipulations:
OF rr�rrr
WATER AND
D
WAST`L.- o
J
By:ametQ Original Certificate Date: 0,
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
CZ���al�T�71
Legal Description: HERITAGE HILLS BLOCK 4 LOT 3
If more than 1 septic system on lot: COSA Checklist # _of
A. WELL DATA —COMMUNITY / PRVT. SHARED
❑ Well log is filed with Onsite (or attached)
Date drilled
Total depth ft
Cased to ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Comments
B. TANK DATA
Age of tank(s) NEW years
Tank type/material ADVANTEX / STEEL
Measured operating fluid level in septic tank NA
® Standpipes/foundation cleanout per record drawing
Date of pumping NA
D. ABSORPTION FIELD DATA
Which system tested (date installed) NEW FIELD
® ALL standpipes present per record drawing
Total measured depth from grade 12 ft (max)
Measured depth to pipe invert from grade 5 ft (min)
❑ N/A — pressurized field
® Monitor tubes go to bottom of effective. If not, state
depth into effective
Parcel ID: 015-221-25
Structure served by this system _
Water storage tank volume NA gallons
Well disinfected for coliform test? ❑ Yes ® No
® Coliform bacteria is Negative
Nitrate 2.32 mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ® Arsenic less than MRL (ND)
FW'
Collected by FVE
Date of Sample
C. LIFT STATION
3/18/2021
❑ Required maintenance completed
Age of lift station _ years
Lift station material
Comments:
Adequacy test date
Results ❑ Pass For bedrooms
Fluid depth prior to test in
Water added gal
New depth in
Elapsed time min
® Code -required soil cover over field Final fluid depth in
❑ System presoaked Absorption rate gpd
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) NA
date of test) If yes, enter date
Gallons introduced gallons
Comments/Deficiencies: Fes:
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
® Yes
if No
Community Sewer Manhole/Cleanout > 100'
❑ Yes
if No
ft
❑ Yes
if No
Neighboring Tank > 100' ❑ Yes
if No
ft
Private Sewer/Septic Line > 25' ❑ Yes
if No
Absorption Field on Lot > 100' ❑ Yes
if No
ft
Holding Tank > 100' ❑ Yes
if No
Neighboring Absorption Fields > 100'
if No
ft
Animal Containment > 50' ❑ Yes
if No
❑ Yes
if No
ft
ft
If septic tank is under driveway comment below
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ❑ Yes
if No
ft
❑ Yes
if No
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
® Yes
if No
ft
Surface Water > 100'
® Yes if No _
Property Line > 5'
® Yes
if No
ft
Wells on Adjacent Lots:
® Yes
Absorption Field > 5'
® Yes
if No
ft
*Private Wells > 100'
® Yes if No _
Water Main > 10'
® Yes
if No
ft
*Community Wells > 200'
® Yes if No _
Water Service Line > 10'
® Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
® Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
® Yes
if No
_ ft
Wells on Adjacent Lots:
Water Main > 10'
® Yes
if No
ft
"Private Wells > 100' ® Yes if No —ft
Water Service Line > 10'
® Yes
if No
ft
Community Wells > 200' ® Yes if No
Surface Water > 100'
® Yes
if No
ft
F. ENGINEER'S COMMENTS
*ADVANTEX SYSTEM 50'-100'+ TO WELLS.
G. ENGINEER'S CERTIFICATION
1 certify that / have determined through field inspections and review
of Municipal records that the above systems are in conformance
with MOA COSA guidelines in effect on this date.
'o GJTH
.... ........
Curtis Huffman
�� �F�•, CE 128991
,A(17/2j,-- \\� 1
PROFESSIONP ..m
ft
ft
ft
ft
ft
ft
ft
ft
MUNICIPALITY OF ANCHORAGE
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and
entered into as of this (O Day of S'< < of 209-1 , by and between
--fa,Wkak �pp CSC,(n , herein the "OWNER," and the Municipality of
Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code
(AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this
Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the
Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS),
described as
located at (legal description)
AN ADVANTEX SYSTEM
HERITAGE HILLS BLOCK 4, LOT 3
2. Maintenance. Repairs and Alterations.
(Owner is required to read, understand and initial each section)
if Throughout the term of this Agreement, the Owner shall enter into a service agreement
with an AWWTS service and maintenance provider approved by the Municipality or the
manufacturer's representative. The AWWTS shall be maintained in a satisfactory
condition capable of performing as designed and producing treated septic effluent in
accordance with the equipment's approval for operation in the Municipality.
TL It shall be the responsibility of the Owner during the term of this Agreement to pay for all
repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This
includes an annual maintenance fee (typically $400 to $600).
Owner agrees that only maintenance and repair personnel approved by the Municipality
or the manufacturer's representative will inspect and make any necessary maintenance,
repairs or permitted alterations to the system.
,('-a- Owner acknowledges that regular maintenance of an AWWTS reduces the potential
failure of the system, which could include sewage backup and costly repairs or drainfield
replacement.
(rev. 05/18/2018) Page 1 of 3
�- Owner acknowledges that the Municipality may request records of maintenance and
repairs from the manufacturer's representative or maintenance provider.
Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be
assessed in accordance with AMC 14.60.030.
Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS. The Municipality will give at least 24-hour notice.
r� Owner agrees that any sale or transfer of title of the property will not occur without a new
Certificate of On -Site Systems Approval.
"Y-4 Owner agrees that the AWWTS installation and maintenance requirements as provided
by the AWWTS vendor/installer and approved by the Municipality are the governing
guidelines for the construction, maintenance and repair of the Owner's AWWTS.
_LZL Owner agrees to maintain remote monitoring of the AWWTS as required by the
AWWTS approval.
3. Term. The term of this Agreement shall begin on the date of approval by the
Municipality to operate the installed system, or upon transfer of title, and shall continue
while the AWWTS is operational or until title is transferred.
4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this
Agreement shall in no way constitute a waiver of the provisions, nor in any way affect
the validity of the Agreement or any part hereof, or the right of the Municipality
thereafter to enforce every provision hereof.
5. Amendment. This Agreement shall only be amended by authorized representatives of
the Owner and Municipality. Any attempt to amend this agreement by either an
unauthorized representative or unauthorized means shall be void.
6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be
brought in the Superior Court for the Third Judicial District of the State of Alaska at
Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the
parties under this Agreement.
7. Severability. Any provisions of this Agreement decreed invalid by a court of competent
jurisdiction shall not invalidate the remaining provisions of the Agreement.
(rev. 05/18/2018) Page 2 of 3
OWNER:
r
By:
(si(Inature) Date:
(print name)
STATE OF ALASKA )
ss.
THIRD JUDICIAL DISTRICT )
The foregoing instrument «vas acknowledged before me this �v day of AFr4
20 j , by 'iCMu4jl tie / -jbl l'lti
EAA:RONPAUL 5. MALIAary Public
e of AlaskaN TARY PUBLIC FOR ALASKn Expires Jul 8, 2023
i ,v Commission expires:
MUNICIPALITY:
BY: (signature)
ro C t (print name)
(rev. 05/18/2018)
Date:y4-9,9
'oo� r'
Title:
Page 3 of 3
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water 8 Wastewater Program
4700 South Bragaw SL
P.O. Box 196650 Anchorage, AK 995196650
' www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 015-221-25
1. GENERAL INFORMATION
Complete legal description
Location (site address or direct)
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
bl b ..
LOUIS do PANNA JARUSSI Day phone 348-8707
10661 OUR ROAD • ANCHORAGE. AK 99516
Day phone
TINA STEVENMEYER W/ COLDWELL BANKER Day phone 265-9145
2525 C STREET • ANCHORAGE, AK 99503
Unless otherwise requested, NAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well ❑
Individual Water Storage ❑
Community Class Or* 0
Public Water System ❑
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
❑
Community On-site
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid
water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water
system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's
work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
Investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application,
shows that the on -situ water supply and/or wastewater disposal system is(are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the
information obtained from the Municipality of Anchorage filos and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING CROUP, Ltd.
Address 3701 E. TUDOR ROAD, SURE 101 » ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, GEG, Ltd. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines 8 Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily Idontiflable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, Ltd. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report Is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party Is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE
_Z Approved for A— bedrooms.
Disapproved.
Conditional approval for
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
bedrooms, with the flowing
Phone 337-6179
Date $ 2 a
Manitenance Agreements
Supplemental Engineer's Reort
Other
By: o 1 Q e , la 1 4 O".n oy',� Original Certificate Date:
(Rw. 1201)
QP�`�YtOFn�Cyo
.•
nN-SITE
Municipality of Anchorage
Development Services Department
Building Safety Division
-- Onsite Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.cl.anchorage.ak.us
(907) 343-7904
HEALTH AUTHORITY AP ROV�L CHECK IST
oe/� S
Legal Description: HERITAGE HILLS SUBDIVISIONLOT BLOCK 4 Parc%
A. WELL DATA CLASS C WELL L TED ON LOTLOCK�IB
'-!Well type COMMUNITY If A• B, or C provide PWSID# 216033ell
Date completed Sanitary seal (Y/N properly protected (YM)
Cased to ! ft. Casing height (above ground) in.
FROM WELL LOG i AT INSPECTION
Date of test
Static water levet ° ft. ft.
.Well production F g.p.m. g.p.m.
WATER SAMPLE RESULTS: E
I ;
Coliform _� colonies/100 ml. Nitrate I mg./L. Other bacteria �colonies/100 ml.
Arsenic: N/A mg./L. Date of sample: 8/117/2004 Collected by: GEG, Ltd.
Y
B. SEPTIClHOLDING TANK DATA 02 TANKS WITH 1 COMPARTMENT EACH INSTALLED. ONE 750 GALLON
ST INSTALLED IN 1972 AND A 500 GALLON ST INSTALLED IN 1977.
Tank Type/Material STEEL I Date installed 8/4/1977 & 9//7/1972
Tank size 01250 gal. Number of Compartments 1 Cleanouts (YM) YES
I[ C
Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (YM) N/A
y
Date of pumping 7/28/2004 Pumper A+ HOME SERVICES
i
C. ABSORPTION FgIELD DATA eETow QVDE ron rs ONLY. TOP Of CRIB 30 eEiow cR�oE
Date Installed 7471977 Soil rating (9.p Vf br bdnn 250 System type CRIB/TRENCH
Length V/71 ft. Width t 18/3 ft. Gravel below pipe 6/7 ft,
•465
Total depth "8.9 ft. Eff. absorption area C 1006ftMonitoring tube YES Depression over field NO
Date of adequacy test "08/16/2004 :;'Results (Pass/Fail) PASS For 4 bedrooms
Fluid depth in absorption field before test 25.5 in. Water added 2387 gal. New depth40 in.
t
Elapsed Time: 157 min. Final fluid depth 35_25 in. Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 me.) (Y/N & type) NONE KNOWN If yes, give date
**TESTED CRIB, CRIB PRESOAKED w/ j1520 GALLONS OF WATER ON 8/13/04. 61.8 INCHES
OF EFFECTIVE MEASURED IN CRIB. 4
D. LIFT STATION
Date installed
"Pump on" level at _in.
E. SEPARATION DISTANCES
Size in gallons
High water alarm level at in.
Cycles tested Meets alarm & circuit requirements?
-
SEPARATION DISTANCES FROM WELL ON LOTTO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
line
PUBLIC WATER
On adjacent
On adjacent
Public sewer manhole/cleanout
Holding tank
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation
5'+
Property line
5'+
Absorption field
5'+
Water service line
'•10'+
Surface water
Water main .
••10'+
Water service line
••10'+
Surface water
100'+
Wells on adjacent lots 100'+/150'+ **PER 1999 SACS ENGINEERING HAA.
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line
101+
Building foundation
10'+
Water main *•10'+
Water service line
'•10'+
Surface water
100'+
Driveway, parking/vehicle storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots *85'/l 41'
F. COMMENTS
WlANER GRANM TO
BLOCK 4. BY
ON LOT 8. BLOCK 4, BY A.D.E.C. ON 12/18/1998 h 7/8/1990
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA HAA guidelines in effect on this date.
Engineer's Printed Name JEFFREY A. GARNESS
Date 19lZ'F/04
V711714115a. . . a
�I • 1
�i, 1 111
3 • Rjl � I i
HAA Fee $ 1 Waiver Fee $
Date of Payment 1) 1)ICA Date of Payment
Receipt Numbero�)l -96 Receipt Number
(Rev. 12/01) 1�`
ar.vfi �
06/102004 12:57 FAX 907 261 2:— PA1tT-TITLE
.. `..r
!i
i.
rJ
J
:TEW TITLE 0002/003
I•d
14D
2616 S92 LOS 0 0 b JaRewuaags eull d21:21 10 OT %nH
Y. •e�aa+ 6 - 4
N69• Ss•q��jy
/SD.ay
°
� W I �'�•
! n
I a•.
I
s ; ;k
a � I
� � t•
:'LR+YrL'•
O Q I
CR41CR7 • \
NB9• S9r 00"W
I
�,4•p. aa•
L-2
Ywu YD 4Y0lYRU163 4Va.'lD w �f..an,T •r Ow R•¢ U.[i.
M aawra TML' YVPYYrUR rw «{ MLl40t®A"VMS AMA p q1>lal 0.tZrY1ML4T 4• V
m VM IOGT •r
URf➢ bRWRi PMVN b•OI KJIYY IRl1[gVGTW Y/.1 ulli 40100 b i'�IL
' .w Y•rr bLRVEr •'FE
naoV.r r..•ar
S� SYY!1olS
r.... waY•r.rYar •
� � i••rl•¢ YrYNI
M ItY ...arPYT... Y«>•n4... »asYYr
b 1MiY0 MfM
�v� JRVC 41Yw >000 rd¢ Eu'i� fa+vtn
YRaI rrYv �
Pl C' PL.«5 ! lAT Steil VtlS
•teV etp
Lj `
I! tl M[ w.o«>e Y•T p 1«L WI{OOl On 0Y«q1� ►mD11 w
OWS1>UC10V. •O VMW MDP® Yul(OYIO OIUD(.n0.•01i[
OYl{• Pn ...IYMrD Mft "OW ** l a Y�0 M>Ylt MNy or
i11�1 �(
1p 11YIYM0) PbC •YD IT11Y 1`YM{CTb•• /,rep {0 a{K>YYK
!a {r Ofy1DY1y, yp(tiyai. DPM..K.
j}G../1( �r0mw
he oD>•41¢ •r •Yr rw4NC«3 DDrouY{S qq11 Pna4cA4na
rMCY OD rq• rsP[�n Al T«C nLCOrnXD iU4O1 W10Y P T.
;IYOY Mwa-�R le•�at . M.. Wa..
r. n�Rlen ywe r..o.olara rYDI, aDl+a a[w wY LDc.KD.
ll lR • .wI b[e.•CnD
AInVEY cam mri
' t
.... ..
iC
et
�-••�—•-
" '
o�ns,
Jr. &Assoc.A
����
,
Pr4fe>lfonMa•1 Land Surveyor•
�r/E"••'
ba
C to aK
If
.. .......-
_�
r• w �.�-ti
^na.er«.•...t
a—wa-1-1
Y
•,
•• %. X121-5
•
0
tr«
Ori
3%1O-ls 99 1'2737 9'9037
,•^
=�= �--
•• ;
LOT 31 (LOCK O. HEA ITAGC HILLS SUdO
�µ�,�i
I•d
14D
2616 S92 LOS 0 0 b JaRewuaags eull d21:21 10 OT %nH
NW -2 -us -27. 2004A 9:33414 Hoi;arness Engineering Group, Ltd
w.,w.Y+z eaftw"w:-W.s....+...a......w... w♦Yw wy Y...afya Y..w.
A+ HOME SERVICES, INC:.
7501 E. 140th Avenue
Anchorage, Alaska 99516
345-I890
CUSTOMER
e annaarusst
- ' ^661 Ot:t�oad
Anch"s, AK 99507
Cloth—_ Lot
70:1383246 110.9315 P. 21,1
.. ,.
INVOICE #
26653
DATE
DCSCRIPTION
AMOUNT
e,
08-26-
p - of e _
$100.0 11
24.0
dim caps
a
,t ••
348-8707
7&103 1200 gagons, 2 staadpipes, 3 hoses2" Gose
TOTAL
. REMIARKS
^C
y
L
)2000anons Septic Leach Area Holding Tank
F Standpipe i
Tim
❑ PROBLEM AREA—CALL FOR MORE INFORMATION
❑ NEEDS TO BE DONE AGAIN IN 6 MONTHS
❑ Good Shape C] sludge buildup on bottom
❑ Iloater on top
❑ Jim cap missing or ❑ Cut standpipe to v above ground
Cl Needs Septictrine
needs replacing
n
LOrli • IVI r
I 5 ; _ l 1, FRANK H. MURKOWSKI, GOVERNOR
LJ .0 ll !_`iLf 1555 Cordova St.
DEPT. OF ENVIRONMENTAL CONSERVATION Anchorage, 99501
/ Phone: (907)2626 9-3076
Fax: (907) 269-7650
DIVISION OF ENVIRONMENTAL HEALTH Sarah Ryghw�dec.state ak us
DRINKING NVATER PROGRAM
http://www.state.ak.us/dee/deh/
CF,RTIFIF,D MAIL 7002 2410 0005 3104 7042
September 12, 2005
File: Heritage Hills S/D Block 4 Lot 8
Carolyn Favorite PWSID: 216033
5201 Huffman Road
Anchorage, AK 99516
Re: Public Water System Reclassification from Class C to Class A
Heritage Hills S/D Lot 8 Block 4
Dear Ms. Favorite:
Our files indicate you own a well on Lot 8 Block 4 of Heritage Hills Subdivision. Our files indicate
this well serves lots 1, 2, 3, 6, 7, and 8 of Block 4 Heritage Hills and that Lot 1 of Block 5 may also
be connected to this system. According to the Municipality of Anchorage records, the total number
of bedrooms on the lots 1, 2, 3, 6, 7, and 8 of Block 4 is 16. The ADEC Drinking Water Program
uses maximum design capacity for assessing water system classification. Residential homes have a
maximum design capacity of 2 people per bedroom. Based on this, the system is designed to serve 32
people (16 bedrooms x2 people). Drinking Water Regulations define a Class C water system as
serving less than 25 people. Class A systems are defined as serving more than 25 residents. Based on
these definitions, your public water system is a Class A public water system.
Your water system will be required to meet the minimum construction standards of a Class A public
water system. You will need to hire an Alaska -registered Professional Engineer to submit a request
for approval to operate a Class A public water system. This request will need to address the
construction standards as well as separation distance requirements of a Class A well. The checklist
for Drinking Water Engineering Plans should be used for this submittal. It can be found on our
website at http://www.dec.state.ak.us/eh/dw/dwma i n/en gineerinp htm1. This request for
operational approval will need to be submitted to our office by December 15, 2005. In addition
to this, routine sampling will now be required of the well. Jamie Stazel of our office will be in
contact to help you with these requirements.
_f ,'r
Separation Distance Waiver, heritage Hills block 4 Lot 8
Any person who disagrees with this decision may request an adjudicatory hearing in accordance with
18 AAC 15.195- 18 AAC 15.340 or an informal review by the Division Director in accordance with
18 AAC 15.185. Informal review requests must be delivered to the Division Director, 555 Cordova
St., Anchorage, Alaska 99501, within 15 days of the permit decision. Adjudicatory hearing
requests must be delivered to the Commissioner of the Department of Environmental Conservation,
410 Willoughby Avenue, Suite 303, Juneau, Alaska 99801, within 30 days of the permit decision. If
a hearing is not requested within 30 days, the right to appeal is waived.
If you have any questions regarding this reclassification, please contact me at 269-3076.
Thank you,
Sarah Rygh, EIT
Environmental Engineer Assistant
cc: Jamie Stazel, ADEC/EH/DW Program
Joe Goodall, Municipality of Anchorage On-site Program
MUNICIPALITY OF ANCHORAGE R----- rve Al r ,lJm
• DEPARTMENT OF HEALTH & HUMAN SERVICES 7
Division of Environmental Services 44
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650 /
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D.# 015'— aal -.05 HAA#
1. GENERAL INFORMATION
Complete legal description
Lot 3, Block 4, Heritage Hills
Location (site address or directions) 12300 Heritage Road
Property owner Ed Butts Day phone 345-1636
Mailing address PO Box 110369, Anchorage, AK 99511
Lending agency Day phone
Mailing address
Agent Day phone
Address
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: 2y v
3. TYPE OF WATER SUPPLY:
Individual well
Community well xxx
Public water
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site xxx
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025(Rev.1191) Front MOAN21 - - -
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm S & S ENGINEERING Phone 6 cl y - a'`7 -7 %
17034 Eagle River Loop Road No. 204
Address
Engineer's signature
6. DHHS SIGNATURE
Approved for
Disapproved.
By:
X02 bedrooms.
Conditional approval for
Date 3 /a ;)./ i 9
7; RCBBRT C. COWAN �� J
Cc -8801
bedrooms, with the following stipulations:
Additional Comments �Oa\ler -*wZ-9900\9
=11Th,,
Date
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given In paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a'certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-025 (Rev. "I) Beck MOA M21
Municipality of Anchorage MAR 1999
DEPARTMENT OF HEALTH & HUMAN SERVjALITYOFANCHORAG
Environmental Services Division ENVIRONMENTAL SERVICES DIVISI —�
s
825 L Street, Room 502 • Anchorage, Alaska 99501 • (907) 343-4744
Health Authority Approval Checklist
Legal Description: Lo 3 J3 H it k,' 4444 H f c( -J Parcel I.D.: O I ( e S
A. WELL DATA
Well type C Lg S S G If A, B, or C, attach ADEC letter. ADEC water system number a) b 3 3
Log present (Y/N) Date completed
Total depth Cased to C eight (above ground)
Sanitary seal (Y/N) Wires properly protected (Y/N)
FROM WELL L AT INSPECTION
Date of test
Static water level
Well producti g.p.m. g.p.m.
WAT SAMPLE RESULTS:
Coliform O Nitrate / 3 7 Other bacteria Q
Date of sample: / / 9 9 Collected by: S & S ENGINEERING
age wertooplloadNo.204
B. SEPTIC/HOLDING TANK DATA Eagle River, Alaska 99577
/,11-77 Soo
Date installed `t 1 '7 17 L Tank size -7 s-() Number of Compartments I Cleanouts &N) V -1 -S
Foundation cleanout o/N) Y rL f Depression (Y/N) N d High water alarm (Yd
Date of Pumping c X X /1 Pumper # .4 14 ° M"t y /cR. V' c e - f
C. ABSORPTION FIELD DATA
77 2/bdrm 1-Ak.�cN
Date installed cf / .7 �/ 7 Z Soil rating (g.p.d./ft2 or S-� System type
i1' 3' 7
Length ;I I Width 1 S Gravel thickness below pipe Total depth 11
)00 4)
Effective absorption area Y 6,5' x7 L Monitoring Tube present O/N) 'Ylf Depression over field (Y/I �' U
Date of adequacy test 3� �o `1 �% Results ( as Fail) 1 For / bedrooms
Fluid depth in absorption field before test (in.); �a Immediately after b o b gal. water added (in.): s S
Fluid depth S'/ �� " (ins) Minutes later: a Absorption rate = Goo -� g.p.d.
Peroxide treatment (past 12 months) (Y/N) If yes, give date
* 'T- a4-- C- N --r/Z' $ r FL n
72-026 (Rev. 3/96)`
D. LIFT STATION
Date installed
Manhole/Access (Y/N)
High water alarm level at*
Cycles
E. SEPARATION DISTANCES
Size in
"Puma " vel at*
*Datum
C stir+ i ry L,,&U(-
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic/holding tank on lot
Absorption field on lot
Public sewer main
line
"Pump off" level at*
_ On a ' centTots
On adjacent lots
Public sewer manhole/cleanout
Lift station
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO:
0
Foundation S 4- Property line (�1 o -) Absorption field
Water main/service line / Surface water/drainage A 0 � � Wells on adjacent lots
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line /o "t Building foundation /0 ../- Water main/service line
Surface water / 0 0
Curtain drain N o r /2- /c Ai 0 v✓,✓
F. ENGINEER'S CERTIFICATION
Driveway, parking/vehicle storage area
VS u f'R/vgTet 5�lc ry
— Wells on adjacent lots
-X' A/3A1t�y6 J /t Y "14ItC. izfig�49y
1 certify that 1 have determined thru field inspections and review of Municipal reco`dkt tl}¢!obS�etems are
in conformance wrt M HAA guide!; es in effect on this date. ,." \
Signature��
�
�JJ r
b � � .2 j � C . C 0 cv a v'
Engineer's Name /C �+
09 by ROBERT .C. COWAN
Date 3/ dg �is'•� CE -$SDI
HAA Fee $ 5 r O-DWaiver Fee $ at> 6 '
c
Date of Payment 3 ' �� j Date of Payment
Receipt Number 4-7 �3 7 (l o J/ Receipt Number /a
72-026 (Rev. 3/96)*
M1,1111e1pality Of Anehorage
Department of Health and Human Services
825 "L" Street
Rick Nlystrom. P.O. Box 196650 Anchorage. Alaska 99519-6650
Mavor
http:!lwww.ci.anchorage.ak.us
April 15, 1999
Robert.C. Cowan, PE
S&S Engineering
17034 N. Eagle River Loop Rd. Suite 204
Eagle River, AK 99577
Subject: Waiver Request for Heritage Hills Block 4, Lot 3
Waiver Request #WR990019
Parcel ID #015-221-25
Health Authority #HA9900106
Dear Mr. Cowan:
Your request for a waiver of the required 100 feet horizontal separation from the
absorption field to private well has been approved. The approved separation distance is
85.0 feet. The well is located on Block 4, Lot 5 Heritage Hills Subdivision.
This waiver approval applies to the existing absorption field to private well separation
only. Any future upgrade to the on-site wastewater disposal system will require all
separation distances be met or another approval from this department.
If there are any further concerns or questions regarding this waiver, please call our office
at 343-4744.
Sincerely,
Donna C. Mears, E.I.T.
Civil Engineer
On -Site Water Quality Program
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-site Services Section
Waiver Review Worksheet
WR#L_ )QCnQDIC� PID# 015-221-25 HA# RA990106 Permit #
Date Received: April 2, 1999
Legal Description: Lot 3 Block 4 Heritage Hills
Engineer: Robert C Cowan, PE, S & S Engineering
17034 Eagle River Loop Road Suite 204 Eagle River Alaska 99577
Applicant: Ed Butts
Waiver Requested: Private seepage pit on Lot 3 Block'4 to the private well on
Lot 5 Block 4.
Criteria: 1. Geology: Points:
A. Water Table 17 �9
B. Soil Sorption %
C. Permeability Z 3
D. Water Table Gradient
E. Horizontal Separation 2
TOTAL: ��•�
2. Special Conditions: tJo.R-
3 . Other:
Waiver is Granted:
W
List Conditions or Reasons for
above:
•QiVI WtO_P�f" S C' a•(�
Date: (S` !�
B
Rec #: 04753/2208 Amounts
$_920.1
Lot 3, Block 4 Heritage Hills Subdivision
Waiver for 85 feet from existing absorption field to existing well.
Issued April 15, 1999
General
1. Due to the topography between the absorption field and well, any surfacing effluent would
initially flow towards the well, but would turn and not run towards the well.
2. The nitrate sample taken from the subject well (Lot 5, Block 4) is 1.99 mg/I. This is consistent
with the nitrate level in the class C well serving the house, it's level is 1.37 mg/L.
3. This situation has existed for over 25 years.
Well
The subject well was likely drilled in 1970 when the wastewater disposal system was installed.
It was deepened to 228 feet in 1978. The static water level is 203 below grade.
Absorption Field
The absorption field, a crib, was installed in 1972. An additional trench was constructed in 1977.
The standpipe of the crib is >100' to the well on Lot 5. Any possible overflow of effluent
would likely surface at this standpipe.
ADEC Point Calculations
Points Property
Values
Water Table 7.6 L5, B4
203 ft.
L3, B3
198 ft. * nearest wells
L6, B3
202 ft. * nearest wells
L2, B1
220 ft.
L5, B1
203 ft.
L7, B1
210 ft.
L8, B1
210 ft.
Average Water Table
207 ft. below surface
Soil Sorption 4.7 clay, sand & gravel L3, 83
L6, B3
sand & gravel L3, B3
L6, B3
Permeability 2.3 clay, sand & gravel L3, B3
L6, B3
sand & gravel L3, B3
L6, B3
Water Table Gradient 2 5% as per engineers report
Horizontal Separation 2.4
Total Points 18.9
198 ft.
170
16 ft.
54
points for % of strata points for
strata type total strata
5.25 84% 4.41
1.5
85
As per ADEC waiver guidelines a point value of 18.9 is almost sure to be free
of any form of contamination from household sewage.
16% 0.24
% of strata points for
total strata
84% 2.10
16% 0.16
points for
strata type
198 ft.
2.5
170
16 ft.
1
54
85
As per ADEC waiver guidelines a point value of 18.9 is almost sure to be free
of any form of contamination from household sewage.
16% 0.24
% of strata points for
total strata
84% 2.10
16% 0.16
s&S�
,ineening
April 1, 1999
ROBERT C. COWAN, P. E.
ROBERTA. SHAFER, P.E.
CIVIL ENGINEERS
(907) 694-2979
,.FAX (907) 694-1211
Municipality of Anchorage
Department of Health and Human Services
HEALTHAUTHORITY
APPROVALS
P.O. Box 196650
Anchorage, AK 99519
REFERENCE: Lot 3, Block 4, Heritage Hills Subdivision
SEWER & WATER
MFJN EXTENSIONS
Request you issue a Health Authority Approval on the referenced property and grant a waiver for
the horizontal separation distance between the crib serving the referenced property and the
private well serving Lot 5, Block 4, Heritage Hills at 85 feet. The mitigation factors involved
which support the issuance of the waivers are as follows:
SEWER & WATER
INSPECTION
1. The horizontal separation distance from the crib to the well is 85 feet. 15% of the required
separation distance is requested to be waived.
2. The samples taken from the well located on the referenced property indicated 1.37 mg/L of
ENGINEERING STUDIES
nitrate and 0 colonies per 100 ml. of bacteria. The results from the well on Lot 5 Block 4 are
AND REPORTS
mg/L of nitrate and colonies per 100 ml. of bacteria.
3. The referenced lot is on a 5% to 10% slope. Surfacing effluent would initially flow towards
the well but would turn to the North and pass the well about 25 feet away.
WELL INSPECTION
& FLOW TEST
4. From the well logs in the area (attached) we can see that the well depths run about 220 to 260
feet. The static water levels are around 210 to 220 feet deep. The distance between the crib and
the water table exceeds 200 feet.
SITE PLANS
5. The soils on the well logs in the area indicate predominately sand and gravel layers with clay
layers between the ground surface and the aquifer. The confining layers would prevent any
effluent from contaminating the aquifer.
ROAD DESIGN
6. The hydraulic gradient is about 5 % towards the well (see attached surrounding well logs).
The granting of this separation distance waiver would not have an adverse impact on the
surrounding properties.
SOILTEST
If you require additional information, please contact us.
Sincerely,
PERCOLATION
TEST
vo//
Robert C. Cowan, P.E.
STRUCTURAL&
RCC/skh
MECHANICAL
INSPECTIONS
Attachments
ONSITE
WASTEWATER
DISPOSALSYSTEM
DESIGN
17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577
MUNICIPALITY OF ANCHORAGE
• Department of Health & Human Services y
DIVISION OF ENVIRONMENTAL SERVICES}�
343-4744
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF
ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING
Parcel I.D. # t%�`7 ZZ�- z� HAA #
1. GENERAL INFORMATION (Must be completed prior to submittal)
(a) Legal Description (include lot, block, subdivision, section, township, range)
Hertitaqe Hills, Lot 3, Block 4
Location (address or directions)
12300 Heritage Road
(b) Property owner Alan & L Kingsbury Telephone: (home) 733-1090 Business
Mailing Address HC 89 Box 8100 Talkeetna, AK 99676
(c) Lending Institution Commonwealth Mortgage Telephone 278-5229
Mailing Address 3333 Denali Anchorage, AK 99503
(d) Real Estate Company and Agent None
Address None
Telephone None
(e) Mail the HAA to the following address: (or check here t, if hold for pick up.)
List contact person and day phone number below:
Please contact Mark Pearson at 696-1700
or Leilani & Alan Kinqsbury at 733-1090
2. TYPE OF RESIDENCE /
Single -Family 8 Number of bedrooms 4
3. WATER SUPPLY v
Individual Well ❑ Community C Public ❑
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to th legality and status.
4. SEWAGE DrI POSAL
On-site ff / Public ❑ Community ❑ Holding Tank ❑
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to the legailty and status.
72-025 (Rev. 7/88) Page 1 of 2
5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this
Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe,
functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and
State codes, ordinances, and regulations in effect on the date of this inspection.
Name of Firm Mountain Engineering
Address 10251 Crestview East
Date 12/29/89
Telephone
Eagle River, AK
,v�S� C7F fji'0o
h
696-1700
99577
Engineer's Seal
MARK W. PEARSON t` M1 fj
CE - 7760
6. DHHS APPROVAL Z-;i�
Approved for bedrooms by -CJ ate
Approved Disapproved Conditional
Terms of Conditional Approval /L,ekt
CAUTION
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval
cerificated based only upon the representations given in paragraph 5 above by an independent professional engineer
registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending
institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections
oranalyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions
in the professional engineer's work.
72-025 (Rev. 7/88) Back Page 2 of 2
MUNICIPALITY OF ANCHORAGE (MOA)
Health -Authority Approval (HAA) r
., Al v'(C}IECKLIST - FEBRUARY 1984
343-4744
r•= y e n -a
A. WELL DATA
Legal Description:
Heritage Hills, Lot 3, Block 4
Well Classification Class C - Community If A, B, C, D.E.C. Approved (Y/N) Y
Well Log Present (Y/N) N/A Date Completed N/A Yield
Total Depth N/A Cased to —
Static Water Level N/A
Casing Height Above Ground —
Electrical Wiring in Conduit (Y/N)
Depth of Grouting
SEPARATION DISTANCES FROM WELL:
To Septic/Holding Tank on Lot
185 FT
Pump Set At
Sanitary Seal on Casing (Y/N)
/ Depression Around Wellhead (Y/N)
_ ; On Adjoining Lots N/A
To Nearest Edge of Absorption Field on Lot 141 FT ; On Adjoining Lots N/A
To Nearest Public Sewer Line None To Nearest Public Sewer Cleanout/Manhole None
To Nearest Sewer Service Line on Lot None
Water Sample Collected by Mountain Engineering ; Date 11/09/89
Water Sample Test Results Passed ( see attached) -Sampling was for DEC's records
Comments Well is part of the Hertitage Hills water system (PWS# 216033 )
See 12/18/89 compliance letter from DEC
B. SEPTIC/HOLDING TANK DATA
Date Installed 9/7/72*Size 1250* No. of Compartments 2 Tanks w/1 Compart. each
Standpipes (Y/N) Y Air -tight Caps (Y/N)
Depression over Tank (Y/N)
Pumping/Maintenance Contact on File (Y/N)
Y
Foundation Cleanout (Y/N) N
r%
Date Last Pumped 8/31/89 (attached)
;for
Holding Tank High -Water Alarm (Y/N) N/A Temporary Holding Tank Permit (Y/N)
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK:
To Water -Supply Well 185 To Building Foundation
To Property Line
45
15
To Disposal Field Field bectins immediately
To Water Main/Service Line Location of water service line is unknown
To Stream, Pond, Lake or Major Drainage Course None
Comments * One 750 gallon ST installed 9/7/72 and an additional 500 gal -
ion tank was installed 8/4/77 (per muni records)
72-026 (Rev. 7/88) Front Page 1 of 2
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata 250 SO FT/BR Type of System Design Crib & Trench
Date Installed 9/7/72 & 8/4/77 Length of Field _ 76 FT trench
Width of Field Est. 3 FT Depth of Field _ 4 FT per records
Gravel Bed Thickness _ 7 FT per records
Square Feet of Absortion Area unknown Statndpipes Present (Y/N) Y
Depression over Field (Y/N) N Date of Last Adequacy Test 12/05/89
Results of Last Adequacy Test passed - 4 bedroom ( see attached)
SEPARATION DISTANCE FROM ABSORPTION FIELD:
To Water -Supply Well 141 FT To Property Line 28 FT
To Building Foundation 45 FT To Existing or Abandoned System on
Lot none ; On Adjoining Lots _80 FT
To Water Main/Service Line unknown To Cutback (if present) none
To Stream, Pond, Lake, or Major Drainage Course none
To Driveway, Parking Area, or Vehicle Storage Area 85 FT
Comments Original crib was installed 9/7/72, and additional drainfield
trench was added 8/4/77. The addition has a length of 76 FT, with un-
known width and depth
D. LIFT STATION
Date Installed none
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Meets MOA Electrical Codes (Y/N)
Comments
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent(Y/N)
Pumping Cycles during Adequacy Test.
"Check Permitted Bedroom Rating Against HAA Request"
I certify that I have checked, verified, or conformed to all MOA and HAA c 41 to i effect on the date of this
inspection. y (�r
Signed Mark Pearson f� V 2
yJ�••••• ,. `B��
Mountain Engineering
Company,
12/29/89 �•••••a) Engineer's Seal
% (5
Date CE89-007 ......
MOA No. Vd vo ; MARK W. PEARSON
CE - 7760 N
n Ilnn J
Receipt No. lC� �/� Receipt
Date of Payment Waiver Fee: $
Amount: $ 4;;W ail- Date of Payment
72-026 (Rev. 7/88) Back Page 2 of 2
o OF o �SK&
DEPT. OF ENVIRONMENTAL CONSERVATION
ANCHORAGE WESTERN DISTRICT OFFICE /
3601 C STREET, SUITE 322
ANCHORAGE, ALASKA 99503
January 8, 1990
Mr. Robbie Robinson
Municipality of Anchorage
Department of Health Human Services
PO Box 196650
Anchorage, AK 196650
Subject: Lot 3, Block 4, Heritage Hills Subdivision
Dear Mr. Robinson:
STEVE COWPER, GOVERNOR
563-6775
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
r; SCO
I�u
RECEIVED
In recent conversation with Mark Pearson on the subject property,
we were informed that an upgrade on the septic system might violate
separation requirements. According to Mr. Pearson, an extension
made on the drainfield line in 1977 placed it within 141 ft, from
the community well between lots 1 & 8. This work apparently
occurred two months after a regulation change was made where the
required separation went from 120 ft, to 150 ft.
In consideration of this type situation where a recent regulation
change has occurred, the Department generally allows a grace period
in which projects are allowed to conform to the older regulation.
In this case, we have found the work to have been completed within
an acceptable time period. No waiver will be required.
If you have any questions, please contact me at our Anchorage
Western District Office at 563-6775.
Sincerely,
Michael P. Lewis, PE
Environmental Engineer
MPL: bas/gd
cc Mark Pearson,
Cindy Thomas, AWDO
HEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC.
5633 B STREET ANCHORAGE, ALASKA 99518 TELEPHONE (907) 562-2343
FEDERAL TAX ID # 92.0040440
ANALYSIS P,EPORT BY SAMPLE for Work Order 3 18186
Date Report Printed: NOV 13 89 0 19:05
Client Sample 10:HERITAGE HILLS WELL
PISID :Uh
Colleetea NOV 9 89 a 17:00 hr.s.
Receivod NOV 10 89 @ 09:30 his.
Preserved pith :AS REQUIRED
Client Name MOUNTAIN ENG13ERING
Client Acct MTHENGN
P.OJ NONE RECEIVED
Req r
Oxderel By : MOUNTAIN ENGINEERING
Anai.ysis Completed :NOV 10 89 Send Reports to:
Laboratory Suporvisoi _3TEPNEN C. EDE 1)MOUNTAIN ENGINEERING
Reloased By 1j�' j
F7
.......... .,nn..a. Ao. a �v �a.:Ae. _ene�nmanayma� a a
Special HOLD UPON COMPLETION FOR. P/U.
Instruct:
Cheralab Ref 4: 8983 Lab Sr,)pl ID: 1 tfatrix: WATER
Allowable
Parameter Tested Ro-ult Units Method Lim is
--- -... - .---------- -
1IITRAiE-N 0.41 :y/1 EPA 353.2 10
Sample ROUTINE SAMPLE, SAtPLE COLLECTED BY 11P.
Bemarks:
1
Tests Performed
Sec
Special Instxuctions Ailove UA,-Unavui).ahla
ND-
Nona Detected
Sea
Sample Renarke Above
fIA-
Not Analyzed
LT -Less
Than, GT.-Gxeatei: Than
MOUNTAIN ENGINEERING ;ii 10251 Crestview East • Eagle River, Alaska 99577
Anchorage 907-696-1700
Outside Anchorage 800-478-0101
SEPTIC SYSTEM ADEQUACY TEST
LEGAL : Lot 3 ; Block 4 ; Heritage Hills Subdivision
ADDRESS : 12300 Heritage Road, Anchorage
OWNER : Alan & Leilani Kingsbury
TYPE : Single Family, 4 Bedroom
WATER SYSTEM : Community - Class C
SEPTIC SYSTEM (According to Municipal Records)
Tank Size : 1,250 gallon
Absorption Type : Crib & Trench
Absorption Area : 468 FT2 (Crib)
994 FT2 (Trench)
Soils Rating : 250 FT2/Bedroom
Installation Date : 9/7/72 (Crib)
8/4/77 (Trench)
DATE OF TEST December 5, 1989
TESTING PROCEDURE
Residence has been continuously occupied, and presoaking was
considered unnecessary.
Standpipes used: One over the crib, one on far end of trenched
drainfield, two on each septic tank, and a cleanout after the
septic tanks.
The drainfield monitoring tube was installed in August, 1989
by Carl's Excavating, and at that time it was not clear if the
drainfield contained piping in all areas. Although Carl found
the gravel prism, he was unable to find the actual piping at
the end of the trench. Dan Roth and Dan Bowles visited the
site and it was concluded that rather than excavating the yard
in search of the pipe, an adequacy test should be performed.
Water was added to the cleanout below the septic tanks at an
average rate of 7.9 gallons per minute until over 600 gallons
had entered the system. Depth to fluid level measurements were
taken at the crib, drainfield, and septic tank. The level in
the septic tank did not vary.
Septic Adequacy Test Lot 3, Block 4, Heritage Hills Page 2
The crib and drainfield fluid levels rose at the same rate
(approximately .3 FT per 20 minutes), and after filling had
stopped, the levels receded at the same rate (approximately
.1 FT per 10 minutes).
TEST RESULTS
THIS SYSTEM MEETS OR EXCEEDS THE CODE REQUIREMENTS OF THE
MUNICIPALITY OF ANCHORAGE.
This analysis was conducted to quantitatively measure the
performance of the above referenced absorption system.
While the system performed more than adequately, a
prediction of the overall operational life expectancy of
the wastewater absorption field is not herein implied.
Operational life expectancy is affected by many variables
such as homeowner maintenance, soils conditions, and
fluctuation of groundwater levels.
,pCH04AGE AY f%� �; ,- C � i 1 .-•� a. � �— ,. - �__
4 [ p P
x yA iii% REATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 C Street, Anchorage, Alaska 99503 274-4561
Date Received November 22, 1976
Time of Inspection 3:00 p.m.
Date of Inspection 11-23-76 Tuesday
J Kennedv
�"Yu��[ JR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
V.A.
1.
Approval requested by:
State of Alaska, Veterans
Administration
Mailing Address: 907 West Northern Lights
Phone: 274-7555
2.
Property Owner: Neal
Hansen
Phone: 344-7957
Mailing Address: Star
Route 1597—H
3.
Legal Description: Lot
3 Block 4 Heritage
/h
4.
Location: Huffman Rd.
turn onto Heritage, 3rd
house on the left
5.
Type of facility to be inspected Single Family No. of bedrooms 4
6.
Well Data:
`1 ti
A. Type Individual
B. Depth
235'
C. Construction
D. Bacterial
Analysis
7.
Sewage Disposal System:
On-site system
A. Installed 1972
B. Installer
C. Septic Tank: 1
D. Seepage Pit: 1.
E. Disposal Field
8. Distances:
Size 2. Manufacturer
© 0
Absorption Area, 2. Material
Total length of lines
A. Well to: Septic tank , Absorption area �, Sewer Lines ,
Nearest lot line Other contamination
B. Foundation to septic tank Absorption area
C. Absorption area to nearest lot line
EQ -034 (1/74)
Page 1 of two pages
1.
2.
3.
4.
5.
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 "C" Street, Anchorage, Alaska 99503 — &1
a76 .7
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
Type of Inspectioh: ZMR(;-VA_ FHA CONY
Property Owner: MOCIA W12nsen
Mailing Address: SR 12l`0 X. I S41-7 14 151 Day Phone .34 q 5
Name of Buyer: NO Ilia L C&A www rA Donn z L41a n
Mailing Address:Day Phone '3
Name of Lending Institution: 4a A- t J A /
Mailing Address: �D7 �.-!) /VOrrhpYn I i G K�C Phone �7q—
^
Name of Realtor or Agent: . . `IW AR 0
Mailing Address: 5i� 1 V0,4 �: a h� �_ Phone 27 (6— 3 T— 13
6. Legal Description:
Locati n: hl
�Q
3 h0oh �`, - --
7. Type of Facility to be inspected: LAICAL �Se4_'j 4% No. Bdrms. _
8. Water Supply ' ''
Type of Supply: Public Utility Individual i'Om►aij.-I IIwe-(l
If Individual, number of dwellings presently served se -le it
If Individual, depth of well .235
9. Sewage Disposal System
Type of System: Public Utility Individual (on-site) X
Page 2 of two pages - Rc st for Approval of Individual er & Water Facilities
hegal"Description Lot 3 Block 4 Heritage Heights
Comments
Approved
Disapproved
Date
Approval,Valid for one year from date signed
Greater Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
�I certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
69NLCI
EQ -034 (1/74)
Date
GREATER ANCHORAGE AREA BOROUGH
Department of Envi ronrnental ,dual i ty
MEVORANDUM
October 18, 1972
TO: C. P. Judkins, R.S.
Dieector
FROM: Rolf Strickland, R.S.
Chief Sarcitaria;,
SUBJECT: heritage hills Subdivision
Some time ago, (approximately one month), a man, (did not give his
nacre), called we in regards to the sale of a lot he owned. The,
inan did not identify himself or tell me where the laird was.
He accused me of advising a prospective client riot to purchase the
land because it was "no good".,
This could not be further from the truth and is a direct lie.
About two montas ago a man, (do not renrermber his name), carne to
me and asked me about the, suitability of a lot in the subject
subdivision. I now know the subdivision in question because you
told me today.
I pulled tie file., obtained fire soils information from the surround-
ing lots and we platted wrrere his k+ell and sewer system should be.
Tiro man was,very_alarmed because there was not sufficient room
replace -the seepage pit on this lot sho iu d the original- frit tie
asked me what would be the proper fining to do, at the time; the
original seepage system quit. I advised him tilt it would have to
be replaced, which was obviously not possible, or he would have to
install a holding tank and pump it weekly. The man said he did not
want to purchase the property under those conditions because of the
possible great expense: of maintaining the sewer system.
I advised him that he sriould ask the seller, to obtain a valid permit
to install an on-site sewer system prior to purchase of the property.
This would insure the purchaser that he could build on his lot.
I never advised him not to purchase the property. I did advise him
that if the: soils did not pass our minimum acceptable standards he
would not be given a permit to install an on-site sewage disposal
system. This is why I also advised him to be sure the seller secured
a valid permit before he purchased the property.