Loading...
HomeMy WebLinkAboutHERITAGE HILLS BLK 4 LT 7 MUNICIPALITY OF ANCHORAGE On-Site Water& Wastewater Program ;.� PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 httpa/wanv.muni.org/onsite 1)(.1r;i rt niu r ,h�X OA 0.GE On-Site Wastewater Disposal System Permit Permit Number: OSP171295 Effective Date: 10/13/2017 Work Type: Septic Upgrade Expiration Date: 10/13/2018 Tax Code Number: 01522129000 Site Legal Address: HERITAGE HILLS BLK 4 LT 7 G:2737 Site Mailing Address: 12321 TRACY RD, Anchorage Owner: LYONAIS DEBORAH A Lot Size in Sq Ft: 15500 Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 2 This permit is for the construction of: 0 Disposal Field El Septic Tank ❑ Holding Tank El Privy ❑ Private Well El Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: Show the waterline on the asbuilt for Inspection Report approval. i Received By: • IV Date: 10 <3 (( Issued By: to C'66-fDate: tl0/1j7/ it '.. Municipality of Anchorage '' e� u i,, „„ P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.muni.orq/Onsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV171121 COSA#: Permit#: OSP171295 PID#: 015-221-29 Legal Description: Heritage Hills B4 L7 Engineer: Garness Engineering Group Applicant: Deborah Lyonais Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 1.5 feet. In addition, the new field may be 10 feet from the existing field. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granine/(,,e) ed: Date: /043//7 Approved by: 1 / Name of Revi-{er *'k** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE ., ;r Community Development Department L // Phone: 907-343-7904 Development Services Fax: 907- -7997 On-Site Water & Wastewater Program 5 5 7 8 9 70 t. Mayor Dan Sullivan �`� /ice On-Site SewerMlell Permit Application a f -. For A Single Family Dwelling For 0 `i 2011 Parcel la D. 015-221-297 Property owner(s) DEBORAH LYONAIS Day pho • .5-1321 4,ti Mailing address PO BOX 231102 ANCHORAGE,AK 99523 6 8 L 9 `' Site address 12321 TRACY ROAD*ANCHORAGE,AK 99507 Legal description (Sub'd, Block& Lot) HERITAGE HILLS; BLOCK 4, LOT 7 Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 2 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: l Mall that apply) Initial ❑ Single Family (SF) Absorption Field ® (w/wo ADU) Septic Tank ® Upgrade Z Duplex (D) ❑ Renewal ❑ Holding Tank E Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE!WAIVER REQUEST FOR: PROPOSED DRAINFIELD TO LOT LINE; DRAINFIELD TO DRAINFIELD Distance: 1.5 FEET; 10 FEET I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: 50 Waiver Fees: AIGDate of Payment: 10/4/1.1 Date of Payment: t'Ul c1(/ Receipt Number: awl266 Receipt Number: Alliao/.�, Permit No. 05 Pl!' l ss� Waiver No. d`5 %-'f21 (Rev 01/11) Quanics.11 All&7211 GARNESS ENGINEERING GROUP, LtdM. ` Cc+LfK t/ CIVIL&ENVIRONMENTAL ENGINEERS Dealer September 26, 2017 f Municipality of Anchorage �I�g! l� Development Service Department -n.4-( S On-Site Water & Wastewater Program A car►S 4700 Elmore Road Anchorage, AK 99507 Ref: Proposed Septic System Upgrade for Heritage Hills; Block 4. Lot 7 To whom it may concern: The existing two (2) bedroom house is served by a private well and septic system. The existing drainfield is in a state of failure and needs to be upgraded. We are proposing to install a new 1000 gallon steel septic tank and deep trench type drainfield. We are proposing to utilize the 1996 testhole by Robert C. Cowan, P.E. with the proposed drainfield designed within its 30 foot radius. Per conversation with the owner of the subject lot, the well that serves the property is located on Heritage Hills; Block 4, Lot 8A. The well was previously designated by ADEC as a Class "C" system; however, recent regulatory changes resulted in former Class "C" wells being re-designated as private wells. In short, we are treating this well as a "private" well with a 100' protective well radius. The well is believed to have 7 service connections in total, and the amount of people served is unknown to GEG. Unless directed otherwise, we are assuming it is still a private well. Comments regarding the design are summarized as follows: 1. SOILS: See the attached 1996 soil log which show the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface water concerns. 4. TOPOGRAPHY: As can be seen on the attached design drawing, the average topography around the proposed drainfield is flat. 5. WAIVER: We are requesting that your department issue a variance from the required separation distance of 10 feet from drainfield to lot line down to 1 .5 feet. We are also requesting a variance from drainfield to drainfield down from 11 feet (5.5 feet of effective) down to 10 feet. Per my conversations with Rebecca Carrol, on 9/26/2017, it is understood that the exact separation distance between the two trenches is currently unknown (due to the location of the existing septic tank). However, in the area separate 3701 East Tudor Road, Suite 101 *Anchorage, Alaska 99507-1259 Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com Page 2 of 2 from the tank excavation a minimum separation distance of 10 feet will be maintained. Justification for granting these waivers is as follows: • The proposed drainfield would not encroach on an adjacent lots septic system with the 1 .5 foot lot line waiver. • We are proposing the use of a diverter valve, only one drainfield will be in use at a time. We are unaware of any adverse impacts this installation or waivers would have on adjacent wells or septic systems. If you have any questions, please contact us at 337- 6179. Thank you for your assistance. (inc rely, Jeffire , a- mess, P.E., M.S. Presi e 3701 East Tudor Road.Suite 101 *Anchorage. Alaska 99507-1259 Phone:(907)337-6179 *Fax:(907)338-3246*Website:www. garnessengineering.com HERITAGE HILLS; i BLOCK 5,LOT 6 Ilk a HERITAGE HILLS; HERITAGE HILLS: BLOCK 5,LOT 7&8 BLOCK 5.LOT 5 I to ',1„ Jcv 1 OfG } Ir S ,p0 ' -40 - I HERIT• E HILLS; ------ --- BLO 5,LOT 4 a,JS i ' ST AVENUE . 1. PP 6.-- I -.4i-p'� ,P 1\ ERIATE HILLS; I BLOCK 4,LOT 5 �41:: /c K, HERI GE HILLS; I •6?) I PPROx t4 R1Ofl BLOGI 4.LOT 4 4144 TE Loc,A TsDN I HERITAGE HILLS; CI I• BLOCK 5.LOT 3 HERITA HILLS; HERIATE HILLS. BLOC 4.LOT 3 I I' , BLOCK 4,LOT 6 ' 49. M SERVED BY WELL1 SERVED BY WELL ON LOT 8A I ON LOT 8A n,� mi .. iiiib SEE DESIGN NARRATEIVE `� REGARDING WELL CLASSIFICATION *-,,,..466, UL..... ! 4, ft ."i Q AGE HILLS; HERITAGE HILLS; v� = • 4,LOT 2 BLOCK 5,LOT 2 .P.--° 1S SER :DBYWELLI • OT BA -.4 - le wi BLOCK ,LOT SA HERITAGE -ILLS; H I ERVED B, WELL( BLOCK 4, OT 1 ON LOT BA BELIEVED TO BE SERVED BY ,I i T WELL ON BLOCK 4,LOT SA �..L SE ED BY WELLHERITAG BLOCK 5,OTS ON LOT BA )4l HUFFMAN ROAD CONTOUR ACRES. CONTOUR ACRES: CONTOUR ACRES. 5 A BLOCK 1,LOT 7 BLOCK 1,LOT 5 BLOCK 1,LOT 3 1'=loci ++rw\\\1ill, GARNESS ENGINEERING GROUP Ltd °:• ..4'I liV . . • ---. CIVIL&ENVIRONMENTAL ENGINEERS • • 3701 E TUDOR ROAD,SUITE 101.ANCHORAGE.AR 99507•PHONE(907)337-6179'FAX(907)338-3246'V4EBS1TE www gamessengneenng.con' • 1 PREPARED FOR: PHONE NUMBER: PAGE NUMBER. 11 1R : J• ,• - ness : 1 DEBORAH LYONAIS 345-1321 1 OF 2 ;.� C7-795 '� '• PROJECT/LEGAL DESCRIPTION: DRAWN BY: I ♦ HERITAGE HILLS; BLOCK 4, LOT 7 D.J.G. •! 9 3 •� � 1. TYPE OF WORK: DATE LICENSE ', FESS ♦;:♦♦ SEPTIC SYSTEM DESIGN UPGRADE SITE PLAN _ 9/27/2017 #AECC8B4 ������ J r rr r HERITAGE HILLS:BLOCK 4,LOT 4 I GEG,Ltd.HAS A 8 PAGE SPECIFICATION DESIGN CRITERIA: LETTER THAT PERTAINS TO THIS DESIGN.TO NOTE:THE CONTRACTOR NUMBER OF BEDROOMS:2 OBTAIN A COPY OF THE LETTER CONTACT SHALL HAVE THE NORTH& GALLONS PER DAY(GPD):300 GEG.BY PROCEEDING FORWARD WITH THIS WEST LOT LINES,AND ALL WELL PERCOLATION RATE/S:8 MI WINCH INSTALLATION,THE ENGINEER,WELL DRILLER, PROPOSED APPLICATION RATE:0.8 _CONTRACTOR AND PROPERTY OWNER AGREE RADII FLAGGED BY A MINIMUM DAINFICA SQ.FT.:375 FT' THAT THEY HAVE READ THESE REGISTERED LAND SURVEYOR SPECIFICATIONS AND AGREE TO ACCEPT THE PRIOR TO CONSTRUCTION. TERMS AND CONDITIONS OUTLINED. DRAINFIELD DESIGN: MAXIMUM DEPTH:13 FEET i WIDTH:2.5 FEET t LENGTH:35 FEET X11 HERITAGE HILLS;BLOCK 4,LOT 3 EFFECTIVE:5.5 FEET -- ACTUAL SQ.FT.:385 FT' • r ' EXISTING \ I I •r-EIEDROON HOUSE \1 / HERIATE HILLS:BLOCK 4.LOT 6 / •,' '. .. `i ` / 1..\\ \ Y •4! .a EXISTING DRAINFIELD ":'.;, TO REMAIN IN PLACE •• a APPROXIMATE LOCATION OF 1996 T H.BY ROBERT C.COWAN, I \ - '. y P.E.PER 1996_INSPECTION REPORT IN MOA RECORDS 4" ;+% :% ` EXISTING 1000 GALLON SEPTIC TANK TO BE =, �T �= S EXCAVATED AND THE VOID FILLED WITH DRAINROCK: SEE DESIGN LETTER AND WAIVER REQUEST 10'WAIVER •• i i APPROXIMATE LOCATION OF ABANDONED 8, I REQUEST,, . 'S i •_ SEEPAGE PIT PER ROBERT C.COWAN ,-u MT O �-- INSPECTION REPORT IN MOA RECORDS 1.5 FOOT WAIVER REQUEST 10+ `RS.% hwitih.... f5'+ 1yj� 11_P_A•B/r_,t PROPOSED 1000\\ GALLON STEEL 10% ` ❑ I EXISTING 2 SEPTIC TANK WITH DOUBLE w BEDROOM �C/O'S BEFORE AND AFTER TANK ``` o HOME J APPROXIMATE LOCATION f / OF EXISTING SEWER LINE Ct O I / DECK / INSTALL FCO IF ONE HERITAGE HILLS;BLOCK 4,LOT 2 / l r IS NOT PRESENT o / �So / r r5 10% 1 1 $o FORMER CLASS"C"WELL O r (NOW PRIVATE)THAT IS % i BELIEVED TO SERVE LOT 7 ' &6 OTHER LOTS _ I I 10'UTILITY EASEMENT /LILT r' 1 r r 1 I 100'WELL RADIUS 1 M ,1 1 G4 I I 1 I 1 1if;1\1 I HERITAGE HILLS;BLOCK 4,LOT 8A WATER LINE TO BE 1 •-- PROFESSIONALLY LOCATED PRIOR TO CONSTRUCTION TO ENSURE % �1 SCALE: SEPERATION DISTANCE TO EXISTING SEWER SERVICE LINE ` 1"=40' * • GARNESS ENGINEERING GROUP,Ltd ; �• ••: 11 - - • '• CIVIL&ENVIRONMENTAL ENGINEERS • 3701 E TUDOR ROAD.SUITE 101•ANCHORAGE.AK 99507'PHONE(907)337-6179•FAX(907)339 m 3246'WEBSITE www garnessengmeering Co ..If • PREPARED FOR: PHONE NUMBER: PAGE %/V:t^ y Afi\t?SS / • DEBBIE LYNOAIS 345-1321 2 OF 2 I4S . CE)79 3 .•'• PROJECT/LEGAL DESCRIPTION: DRAWN BY: 42 a ��1 j I 13./C.,HERITAGE HILLS; BLOCK 4, LOT 7 D.J.G. �1+'c j• •''••••• •• ESS‘� , 46. TYPE OF WORK: DATE 444LICENSE •\i>♦11� « I,•' SEPTIC SYSTEM DESIGN UPGRADE 10/11/2017 #AECC884 PROF_ i Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~ q ~ 0';~'-~7 PID Number: Oi ~ - '~ ~Z ~ Name: ~ ~opF~TT Wastewater System: D New ~ Upgrade Address: ~ ~ ~, ~-~ ~TZ~ .~ ~,~. ABSORPTION FIELD Phone: ~.. ~ INo. o~edr°°ms: ~DeepTrench ~ Shallow Trench ~Bed ~Mound ~Other Total Depth from original grade: LEGAL DESCRIPTION S°ilRating: O.~ GPD/Sq. Ft. Subd[v~ion: Depth to pipe boRom from original grade: Gravel depth beneath pipe Township: ~ ~ Range: .~ Section: ~ Fill added above originaIo grade: Ft. Gravel Length: *~ ~ Ft. I Gravel width: Number of lines: Distance baleen lin~; WELL: Cx,5~,~ew D Upgrade / ~.~t Ft. I ~ Ft. Classification (Private, A,B,C): Total ~ ~ed To: ~Total absorption area: Pipe material: Driller: ~ Date Drilled: Static Water Level: Installer: Date installed: PM Ft. Ft. SEPARATION DISTANCES ~s~mi~ ~ Holding D S,T.E,P. To Septic Absorption Lift Holding 3ublic/Private Manufacturer: Capacity in gallons: From Tank Field Station Tank Sewer Lines ~ ~ ~ ~ ~O ~. i ' ~ Material: Number of Compa~ments: su~c~ -- LIFT STATION LineL°t Jli &~ ~ i ~ ~ ~ Size in gallons: Manufacturer:~ ~ "Pump on"~" level at: High water alarm at: Foundation j ~ ~ ~ ~ Cu~ainDrain " - ~ ,~l ~, K~{ ~'~ ~od~chi~l I~pections pedormed by: Remarks: BENCH MARK Location and Description: Inspections pedormed by: iJo~q ~agie River Loop Road, ' .......... Department of Health and Human Se~ices approval ~,,;~,.....<:.. ,, Reviewed and approved by: ) Date:/~ - ~- ~'~'" " ' '~ 72-013 (Rev. 9/91) MOA 25 Permit No. SW960567 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report LegalDescription: LOT 7, BLOCK 4, HERITAGE HILLS S/D PIDNo.: 015-221-29 PARKING AREA IEW 'lNG SEPTIC AND 100' RADIUS Ld 1000 GAL. 10' UTIL SCALE 1" =40' ST1 NIgW 1000 SEPTI~ ST2 SAL [NAL GRADE ---~ CO1 = 95.2' C02 = CO¸ CO; NO 72-013 A (Rev. 9/91) MOA 25 = 101.3' · FOUND 3.8' B.O.H. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW960367 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:PROFFETT JOHN M OWNER ADDRESS:5201 HUFFMAN RD ANCHORAGE, ALASKA 99516 DATE ISSUED:il/25/96 EXPIRATION DATE:il/25/97 PARCEL ID:01522129 LEGAL DESCRIPTION: HERITAGE HILLS BLK 4 LT 7 LOT SIZE: 15500 (SQ. FT.) NUMBER OF BEDROOMS: 2 THIS PERMIT: 2 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ~~f ~~ DATE: // HEALTH AUTHORITY APPROVALS SEWER & WATER MAIN EXTENSIONS SEWER&WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE W~TEWATER DISPO~Ak SYSTEM DESIGN ROBERT C. COWAN, RE. ROBERT A. SHAFER, RE. October 6, 1996 CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 7, Block 4, Heritage Hills Subdivision Request you issue of a permit to upgrade the septic system serving the existing %~o bedroom house on the referenced property. A waiver is requested from the proposed trench to the North and West lot lines at i foot. A waiver request for the Class "C" well located on Lot 2, Block 5, Heritage Hills S/D is being requested from A.D.E.C. concurrent with this request under seperate cover. A test hole was excavated and percolation test performed in the area of the proposed upgrade. The approximate location of the test hole is located on the attached site plan. At the time of excavation no water was after seven day ground water monitoring, tube was found to be dry. Attached is the proposed upgrade design. encountered and the monitoring This property is served by a Community Water System. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. If you require additional information, please contact us. Sincerely, Robert C. Cowan, m. ~.. RCC/gk MUNICIPALITY OF ANCHoklAGE ENVIRONMENTAL SERVICEs DIVISION OCT 11 1995 RECEIVED Enclosure 17034 NORTH EAGLE RIVER LOOP" SUITE 204" EAGLE RIVER, ALASKA 99577 ~4::ALE SITE PLAN I F-- DESIGN Ti~ACY I~OAD z~og 0 EXISTING 2 BDRM HOUSE m --4 10' UTIL, ESMT .:~ Z ~0~ DETAIL PROFILE SCALE TO BEDROCK ~':FO4"G ROU N D WATER ' t 5' DEEP , 'I" = 50' DESIGN __DETAIL TRACY ROAD ~~N EXISTING ~ ~ ~ HOUSE o ~ >~-- ~-- ~ oc ~ ~ ........ / / / ~ = 30' DESIGN DETAIL TRACY ROAD EXISTING 2 BDRIVl HOUSE 10' UTIL, ESMT. m Z m ROBERT C. COWAN, P.E. ROBERT A. SHAFER, P.E. ON-SITE WASTEWATER DISPOSAL SYSTEM ClVILENGINEERS (907) 694-2979 CONSTRUCTION PRACTICES FAX(907) 694-1211 and MATERIAL SPECIFICATIONS STRUCTURAL & MECHANICAL iNSPECTIONS HEALTH^UmOR~TY REFERENCE: Lot 7, Block 4, Heritage Hills Subdivision APPROVALS October 6, 1996 GENERAL: 1. The scope of this project includes the installation of SEWER&WATER ~IN~TENSIONS a 1000 gallon septic tank and a leachfeild trench to serve the two bedroom residence located on the referenced property. The existing septic tank and the existing crib are to be excavated, pumped, crushed, S~VER&W^TER and abandoned completely. INSPECTION 2. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all ENGINEERtNGSTUDIES applicable State and Municipal Wastewater Disposal AND REPORTS Regulations. 3. The contractor shall be responsible for obtaining any necessary underground utility locates. WELL INSPECTION & FLOW TEST 4. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. SITE PLANS 5. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the ROADOES,GN Municipal Health Department. ~EPTIC TANK INSTAL.LATION: SOILTEST 1. A septic tank ';s to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. PERCOLATION TEST 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. Ail standpipes on the septic tank shall extend a minimum of 12 inches above final grade. ON SITE WASTb~NATER OISPOSALSYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 Page Two Lot 7, Block 4, Heritage Hills Subdivision October 6, 1996 e Se Septic tanks installed with less than 4 ft. of cover shall be insulated. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock) placement. Once the gravel is installed~ the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. e Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade° The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Page Three Lot 7, Block 4, Heritage Hills Subdivision October 6, 1996 Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron ASTM D3034 (PVC) ASTM F810 (HDPE) ASTM D2662 (ABS) Yes Yes Yes Yes Yes No Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with ].ess than 3% passing the 9200 sieve. 7e When sand is being used as a filter material, its gradation specifications must conform to current M.O~A. or D.E.C. requirements, which ever applies~ Page Four Lot 7, Block 4, Heritage Hills Subdivision October 6, 1996 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: e The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M~O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. Page Five Lot 7, Block 4, Heritage Hills Subdivision October 6, 1996 S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER PERFORMED FOR: ~J' 0 ~j~/ LOT' LEGAL DESCRIPTION: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST r: ~.,~- ROBERT C. COWAN ~,.'"~,'J"-.. CE - 8801 /~";. 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O IV~L ~ 0 jcl/ WAS GROUND WATER J~ O ENCOUNTERED? IF YES, AT WHAT ~ DEPTH? Depth to Water After /~//~ Monitoring? Dr°'"'/ Date: ,/0 ~ SLOPE SITE PLAN I Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN /O ~-~. FTAND il ~/3_________________~. FT COMMENTS PERFORMED BY: 1)0;f4 Eagle River Loop Road No. 204 ' ~ ~ ' ' ' ACCORDANCE WI'i~._I~eT'~i~'~L~[~L GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING GENERAL INFORMATION Complete legal description Lot 7; Block 4; Heritage Hills Subdivision Location (site address or directions) Tracey Road Anchorage, AK Prope~y owner John & Hilde Proffett Day phone 345-5480 Mailing address P.O. Box 772066 Eagle River, AK 99577 Lending agency Mailing address Agent Address Alaska USA Federal Credit Union Day phone 786-2726 Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well NOTE: Public water If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site NOTE: xx~ Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system~ 72-025 (Rev. 1/91) Front MOA #21 STATEMENT OF INSPECTION BY ENGINEER. As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm S & S ENGINEEEING i~034 Eagie ~,iver Loop ~oad No. ~0~t Phone d"c/ Address Eagle River, ~Alaska 99577, Engineer's signature '~--~Z. ~"(~-- Date DHHS SIGNATURE Approved for ~- Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments Date ./2- 7- ~'~' The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-O25(Rev. 1/91) Back MOAIffZ1 of Anchorage DEC; 0 Municipnlity DEPARTIVIENT OF HEALTH & HUIVlAN SERVICES Environmental Services Division R [ C ~ 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744 Legal Description: A. WELL DATA Well type Log present (Y/N) Health Authority Approval Checklist Total depth San! '~4. ~ If A, B, or C, attach ADEC letter. ADEC water system number ~. Date completed. ~ C,a.se~ Casing height (above ground) FROM WELL LOG / Date of test / // Static water level Well production WATER SAMPLE RESULTS: Coliform 0 Nitrate Date of sample: I i - B. SEPTIC/HOlDING TANK DATA Date installed it-Z"i"-"~, Tanksize Foundation cleanout (~N) Date of Pumping Wires properly protected (Y/N) AT INSPECTION g.p.m, g.p.m. Collected by: Other bacteria O $ & S ENGINE~IN~ 17034 Eagle River Loop Road, No. 204 Eagle River, Alaska I ¢:~_~,,~ Number of Compartments ~ Cleanouts(~)N) Depression (Y/~ ~ O High water alarm (Y~ Pumper '"~------~ C. ABSORPTION FIELD DATA Date installed J ~ - 2 1 - c~ C Soil rating ~or ft2/bdrm) ~ .' ~ System type Length ~ Width ~-. ~ ~ Gravel thickness below pipe 5o 5 Total depth Effective absorption area ~'?,~ d Mon toring Tube present (~1). Y~$ Depression over field (Y~) ~j~ o Date of adequacy test ~ F~.J Results (Pass/Fail) '-"-- For Fluid depth in absorption field before test (in.); ~ Immediately after '"- gal. water added (in.): Fluid depth ~ (ins) Minutes later: ~ Absorption rate = ~ _g.p.d. Peroxide treatment (past 12 months) (Y/N) If yes, give date bedrooms 72-026 (Rev. 3/96)* D. LIFT STATION ...... Date installed Size in gallons ._-.- Manhole/Access (Y/N) "Pump~r~ "Pump elf"level at* High water alarm level at* __~*Datum E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot Public sewer main On adjacent lots __.--.-----'"" Public sewer manhole/deanout Lift station SEPARATION DISTANCES FROM~HOLDING TANK ON LOTTO: t Foundation ~J I Property line ! I Absorption field Water main/service line ~ot~ Surface water/drainage j OoI+ Wells on adjacent lots ,7j SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Property line ,,4.,~,~ab Building foundation 'Z.Z, Water main/service line Surface water 100! -t" Driveway, parking/vehicle storage area __ Curtain drain ~/~ Wells on adjacent lots HAAFee $ ~E~r~:~.) Date of Payment / ~-//'~ /~,,~'~ Receipt Number '~'~-- ~'7 ~/~ / ENGINEER'S CERTIFICATION .;~ t~JN4~12, I certi~ that I have determined thru field inspections and review of Municipal records th~~ x{tems are in conformanc A'guideliaes in effect on this date. Engineer's Date / ~ /~/~ Waiver Fee $ Date of Payment Receipt Number 72-026 (Rev. 3/96)* DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE WESTERN PUBLIC SERVICE OFFICE 555 CORDOVA STREET ANCHORAGE, ALASKA 99501 November 18, 1996 TONY I~lv~vvr.~-'-', '"' ......... (907)269-7505 Mr. Robert C. Cowan, P.E. S & S Engineering , 17034 North Eagle River Loop, Suite 204 Eagle River, Alaska 99577 SUBJECT: Lot 7, Block 4, Heritage Hill Subdivision, Separation Distance Waiver AWPSA Project Number 9721-DW-284~043, Review Dear Mr. Cowan: This letter is in response to the submittal received on November 4, 1996, in which you address the concerns noted in my October 23, 1996, letter regarding the following separation distance waivers: Between a Class C Public System Source Well on Lot 2, Block 5 and the septic tank on Lot 7, Block 4 from 150 feet to 107 feet. Between a Class C Public Water System Source Well on Lot 2, Block 5 and the soil absorption system on Lot 7, Block 4 from 150 feet to i04.5 feet. We have completed our review of the submitted information which include a cover letter, soils logs,, site plan, well logs, some geological data, and water quality analysis of the water from the source well on Lot 2, Block 5. From our review, it appears the lesser separation distance could provide the need treatment of the wastewater which is need to protect public health and the environment. Therefore, in accordance with the provisions of 18 AAC 80.030, the above noted separation distances are granted. The following are requirements of the above granted waiver: Verification that the vertical separation distance of four (4)feet between the lowest part of the soil absorption system and the seasonal high ground water has been meet. In addition, verification of the in-situ soils will need to be submitted to this office. Mr. Cowan 2 November 18, 1996 As-built drawings, under the stamp of a Professional Engineer (P.E.), needs to be' submitted to this office within 90 days of completion of the project. The as-built drawings will need to include a cross section of the soil absorption system. This waiver will remain valid until the wastewater disposal system on Lot 7, Block 4 again requires upgrading. If upgrading or replacement is necessary, due to the small lot size and the high density of wastewater disposal systems, additional treatment to the waste stream will be a requirelnent of any futurq waiver requests for this property. This approval to construct does not imply the granting of additional authorizations, nor obligate any federal, state, or local regulatory agency to grant the required authorizations. Thank you for your cooperation and coordination with this Department. If you have any questions, please do not hesitate to contact me. S, incerely, Environmental Engineer cc: Jim Cross, P.E., MOA/DHHS KKK/ph Rick Mystrom, Mayor of Anchorage DePartment of Health and Human Services 825 "U' Street P.O. Box 196650 Anchorage, Alaska 99519-6650 December 9, 1996 Robert C. Cowan, P.E. S & S Engineering 17034 Eagle River Loop Road Eagle River, Alaska 99577 Subject: Waiver Request for Lot 7 Block 4 Heritage Hills Subdivision Waiver Request #WR960055, PID #015-221-29, HA960529 Dear Mr. Cowan: Your request for a waiver of the required 10 foot separation between an on-site wastewater disposal system and a lot line has been approved. The waived distance is 1 foot from the north and west property lines to the absorption field. This approval applies to the existing on-site wastewater disposal system lot line separation only. Any future upgrade to the on-site wastewater disposal system will require all separations be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-4744. Sincerely, Civil Engineer On-site Services Program DJR/Ijm: Proffett k-~MUNICIPALITY OF ANCHORAGEmj Department of Health and Human Services On-site Services Section Waiver Review Worksheet WR# WR960055 PID# 015-221-29 HA# Date Received: October 11, 1996 Legal Description: Lot 7 Block 4 Heritage Hills Subdivision Engineer: Permit # Robert C. Cowan, P.E., S & S Engineering 17034 North Eagle River Loop, Suite 204, Eagle River, Alaska 99577 Applicant: John Proffett ~ Waiver Requested: Lot line waiver of 1 foot from the North and west lot lines absorption field Criteria: 1. Geology: Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation TOTAL: 2. Special Conditions: 3. Other: Waiver is Granted: ~ Waiver is NOT Granted: List Conditions or Reasons for above: fRg ~6/N£F~£ ~-~/~p Date: II-- /~--~ By: Name of Reviewer Rec #: ~\ I~5 Amount: $ ~ Date Paid: DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE WESTERN PUBLIC SERVICE OFFICE 555 CORDOVA STREET ANCHORAGE, ALASKA 99501 TONYKNOWLE~ GOVERNOR (907) 269-7505 October 23, 1996 Mr. Robert C. Cowan, P.E. S & S Engineering 17034 Eagle River, Suite 204 Anchorage, Alaska 99577 RECEIVED Municipality o~Anch~°ra~e · Dept. Health & Human ~8rvices Subject: Lot 7, Block 4, Heritage Hill Subdivision, Separation Distance Waiver, Anchorage, Alaska, AWPSO Project 9721-DW-284-043, Review Dear Mr. Cowan: This letter is in response to your October 9, 1996 submittal in which you requested this Department to waive the separation distance between the Class C Public Water System on Lot 2, Block 5, Heritage Hill Subdivision and the proposed wastewater treatment and disposal system on Lot 7, Block 4, Heritage Hill Subdivision from 150 feet to 100 feet. I have completed my review of the submitted information, information in this office's files regarding public water systems and wastewater disposal systems in the Heritage Hill Subdivision, and our October 23, 1996 conversation, I have the following comments: The Department has already granted similar waiver (150 feet down to 100 feet) between the Class C Public Water System Source Well and the wastewater disposal system on Lot 2, Block 5. This waiver was granted based on the fact that the engineer proposed additional treatment for the wastewater stream prior to being discharged. This makes the review of your request very difficult. As we discussed on October 23, 1996, i have two choices in regards to your waiver request. The first is to deny your request on the grounds that for the subject Class C Public Water Source Well, the approved mitigating factor is the requirement for additional treatment (treatment above what is provided in a septic tank) of the wastewater stream. The second choice is to request additional information in accordance with procedures outlined in 18 AAC 72.015(b)(2) and (3). I believe that at this time my second choice is the proper way to resolve the concerns with this waiver request. Please provide additional information to address the following items: Describe soil classifications, groundwater conditions, surface topography, geology, and any other environmental conditions that would assist the department in establishing a lesser separation distance. Mr. Robert C. Cowan, P.E. October 23, 1996 Page 2 Include a set of plans of the proposed wastewater disposal system for lot 7 Block 4, the set of plans must include an accurate description and location of potential sources of contamination, surface water, and existing or potential drinking water sources in the area. Information that should be used to address the two items noted above are either well logs or well probe results from source wells located in Blocks 4 and 5 of Heritage Hill Subdivision. Please include as accurate as possible distance mea. surements between the source well on Lot 2, Block 5 and all components of the proposed wastewater disposal system on Lot 7, Block 4. Another reason the issuance of this waiver is diffic'ult is the fact that the lots in this ..subdivision were not designed to have on lot wastewater disposal systems and drinking water systems as the final solution to wastewater and water concerns. It is obvious that with the smaller lots, community water distribution and wastewater collection were the final solution for wastewater and water concerns for this subdivision. Thank you for your cooperation with this Department. If you have any questions, please do not hesitate to contact me. Sincerely, / ~ Keven K Kleweno, P.E. Environmental Engineer KKK/ph cc: Jim Cross, P.E., MOA, DHHS, DATE ,TIME ~ TIME TiME 3ATE DATE DATE I NSP~~ INSPECTOR I NSP ECTOR MUNICIPALI~ OF ANCHORAGE ENVIRONMENTAL P~O~EC~ON MUNICIPALITY OF ANCHORAGE  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1, Incomplete requests will not be proce~ed, Please allow ten (10) days for processing. 1. PROPER~ OWNER ¢ PHONE MAILING A~RESS PROPER~Y RESIDENT (~f different from ~bove) PHONE ~. ~UY~R ~ PHO~ MAILING ADD~ES~ MAILING ADDRESS MAILING ADDRESS - / , , 5. LEGAL DESCRIPTION 16. TYPE OFA[Sl~[~g[ ~GLE FAMILY MULTIPLE FAMILY N~M~EH O~EEDROOMS [] One [] Four ~ Two [] Five [] Three [] Six [] Other 7, WATER SUPPLY [] INDIVIDUAL* COMMUNITY [] PUBLIC UTILITY *ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach log if available.} 8. SEWAGE DISPOSAL SYSTEM ~ INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY / ~'7~'-' 'YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [~ SINGLE FAMILY E3 ONE [] THREE E~ FIVE E~ OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE INSTALLED Connection Verified . INSTALLER []Septic Tank or [] Holding Tank . Size: '~ ~ If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES Septic/Holding Tank Absorption Area Fewer Line Nearest Lot Line WELL TO: Absorption Area to nearest Lot Line 5, COMMENTS [~*/~,PP ROV E D FOR ~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED DATE BY 72-010 (Rev. 6/79) January 4, 1980 Ronald J. Hildebrand Post Office Box 1063 Wasilla, Alaska 99687 Subject: Lot 7 Block 4 Heritage Hills Subdivision Approval for your individual sewer and water facilities can not be granted until the following items have been completed: (1) The water analysis report be delivered to this office from Ch~ Lab, 5633 B Street, for our review. (2) The septic tank pumped with a receipt submitted to this office° (3) An adequacy test be perfommed on the existing leaching area. This test will determine if the system is adequate according to National Standards. A listing of private fir~s performing the test is enclosed. If there are any further questions, please contact this office at 264-4720. Sincerelyt. Robert C. Pratt~ R.S. Associate Specialist R~P/lJw National Bank of kAlaska Pouch 7-025 99510 Doug Taylor % Jack White Company 3201 C Street 99503 January 11, 1980 R~i No. 051001 Ron Hildebrandt P.O. Box 1063 Wasilla, Alaska Re: Adequacy Test on Existing Sanitary Sewer System; Lot 7, Block 4, Herritage Hills Subdivision, Anchorage, Alaska Dear Mr Hildebrandt: Per your request of January 3, 1980, we conducted a test of the sanitary sewer system on the above described property. During this test the liquid level in the septic tank was monitored as water was added to the system. The measurements are summarized in the following table: Time Liquid Level Below Top of Standpipe Total Gallons Added 2:30 6.1' 0 2:35 6.05' 25 2:41 6' 50 2:47 5.9' 75 2:53 5.7' 100 3:03 5.9' 125 3:05 6.1' 125 The meter used had previously during the test was a Rockwell 5/8" standard water meter which been calibrated by R&M Consultants, Inc. ANCHORAGE FAIRBANKS JUNEAU VALDEZ WASILLA January 11, 1980 Ron Hildebrandt Page -2- If the 2 bedroom residence on the property is to house 4 people, the average load on the system can be expected to be 300 gallons per day or .21 gallons per minute. During the test, the system accepted 125 gallons in 35 minutes. This indicates an average effluent acceptance rate of approximately 3°6 gallons per minute at the time of the test. We can therefore conclude that the system is disposing of effluent at an adequate rate for a 6 bedroom residence. We appreciate this opportunity to be of service to you. Please contact us if you have any questions concerning this test or if we can be of additional service. Very truly yours, R&M CONSULTANTS, INC. Staff Geologist ERR/GAS/dj/AT&SI-P Project Manager