On-Site Wastewater Disposal System Permit
Permit Number: OSP171295 Effective Date: 10/13/2017
Work Type: Septic Upgrade Expiration Date: 10/13/2018
Tax Code Number: 01522129000
Site Legal Address: HERITAGE HILLS BLK 4 LT 7 G:2737
Site Mailing Address: 12321 TRACY RD, Anchorage
Owner: LYONAIS DEBORAH A Lot Size in Sq Ft: 15500
Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 2
This permit is for the construction of:
0 Disposal Field El Septic Tank ❑ Holding Tank El Privy ❑ Private Well El Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: Show the waterline on the asbuilt for Inspection Report approval.
i
Received By: •
IV Date: 10 <3
((
Issued By: to C'66-fDate: tl0/1j7/
it
'.. Municipality of Anchorage '' e�
u i,, „„
P.O. Box 196650 • 4700 Elmore Road
Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997
http://www.muni.orq/Onsite
Development Services Division
On-Site Water and Wastewater Program
**** VARIANCE/WAIVER REVIEW ****
Waiver#: OSV171121 COSA#: Permit#: OSP171295
PID#: 015-221-29
Legal Description: Heritage Hills B4 L7
Engineer: Garness Engineering Group
Applicant: Deborah Lyonais
Your request for a waiver of the required 10 feet horizontal separation from the absorption field
to the property line has been approved. The approved separation distance is 1.5 feet. In addition,
the new field may be 10 feet from the existing field.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacent property.
® Adjacent properties are not affected by this waiver.
Waiver is Granted: X Waiver is not Granine/(,,e)
ed:
Date: /043//7 Approved by: 1 /
Name of Revi-{er
*'k** VARIANCE/WAIVER REVIEW ****
MUNICIPALITY OF ANCHORAGE
., ;r
Community Development Department L // Phone: 907-343-7904
Development Services Fax: 907- -7997
On-Site Water & Wastewater Program 5 5 7 8 9 70
t.
Mayor Dan Sullivan �`� /ice
On-Site SewerMlell Permit Application a
f -.
For A Single Family Dwelling For 0 `i 2011
Parcel la D. 015-221-297
Property owner(s) DEBORAH LYONAIS Day pho • .5-1321 4,ti
Mailing address PO BOX 231102 ANCHORAGE,AK 99523 6 8 L 9 `'
Site address 12321 TRACY ROAD*ANCHORAGE,AK 99507
Legal description (Sub'd, Block& Lot) HERITAGE HILLS; BLOCK 4, LOT 7
Legal description (Township, Section & Range)
Lot Size Sq.Ft. Number of Bedrooms 2
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING:
l Mall that apply) Initial ❑ Single Family (SF)
Absorption Field ® (w/wo ADU)
Septic Tank ® Upgrade Z
Duplex (D) ❑
Renewal ❑
Holding Tank E Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE!WAIVER REQUEST FOR:
PROPOSED DRAINFIELD TO LOT LINE; DRAINFIELD TO DRAINFIELD Distance: 1.5 FEET; 10 FEET
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 50 Waiver Fees: AIGDate of Payment: 10/4/1.1
Date of Payment: t'Ul c1(/
Receipt Number: awl266 Receipt Number: Alliao/.�,
Permit No.
05 Pl!' l ss� Waiver No. d`5 %-'f21
(Rev 01/11)
Quanics.11 All&7211
GARNESS ENGINEERING GROUP, LtdM. `
Cc+LfK t/
CIVIL&ENVIRONMENTAL ENGINEERS Dealer
September 26, 2017 f
Municipality of Anchorage �I�g! l�
Development Service Department -n.4-( S
On-Site Water & Wastewater Program A car►S
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic System Upgrade for Heritage Hills; Block 4. Lot 7
To whom it may concern:
The existing two (2) bedroom house is served by a private well and septic system. The
existing drainfield is in a state of failure and needs to be upgraded. We are proposing to
install a new 1000 gallon steel septic tank and deep trench type drainfield. We are
proposing to utilize the 1996 testhole by Robert C. Cowan, P.E. with the proposed
drainfield designed within its 30 foot radius. Per conversation with the owner of the
subject lot, the well that serves the property is located on Heritage Hills; Block 4, Lot 8A.
The well was previously designated by ADEC as a Class "C" system; however, recent
regulatory changes resulted in former Class "C" wells being re-designated as private
wells. In short, we are treating this well as a "private" well with a 100' protective well
radius. The well is believed to have 7 service connections in total, and the amount of
people served is unknown to GEG. Unless directed otherwise, we are assuming it is still
a private well. Comments regarding the design are summarized as follows:
1. SOILS: See the attached 1996 soil log which show the soil classifications,
groundwater monitoring, and the percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There are no surface water concerns.
4. TOPOGRAPHY: As can be seen on the attached design drawing, the average
topography around the proposed drainfield is flat.
5. WAIVER: We are requesting that your department issue a variance from the required
separation distance of 10 feet from drainfield to lot line down to 1 .5 feet. We are also
requesting a variance from drainfield to drainfield down from 11 feet (5.5 feet of
effective) down to 10 feet. Per my conversations with Rebecca Carrol, on 9/26/2017, it
is understood that the exact separation distance between the two trenches is currently
unknown (due to the location of the existing septic tank). However, in the area separate
3701 East Tudor Road, Suite 101 *Anchorage, Alaska 99507-1259
Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com
Page 2 of 2
from the tank excavation a minimum separation distance of 10 feet will be maintained.
Justification for granting these waivers is as follows:
• The proposed drainfield would not encroach on an adjacent lots septic system
with the 1 .5 foot lot line waiver.
• We are proposing the use of a diverter valve, only one drainfield will be in use at
a time.
We are unaware of any adverse impacts this installation or waivers would have on
adjacent wells or septic systems. If you have any questions, please contact us at 337-
6179. Thank you for your assistance.
(inc rely,
Jeffire , a- mess, P.E., M.S.
Presi e
3701 East Tudor Road.Suite 101 *Anchorage. Alaska 99507-1259
Phone:(907)337-6179 *Fax:(907)338-3246*Website:www. garnessengineering.com
HERITAGE HILLS; i
BLOCK 5,LOT 6
Ilk
a HERITAGE HILLS;
HERITAGE HILLS: BLOCK 5,LOT 7&8
BLOCK 5.LOT 5
I
to ',1„ Jcv 1
OfG }
Ir S ,p0 '
-40 - I
HERIT• E HILLS; ------ ---
BLO 5,LOT 4 a,JS i ' ST AVENUE .
1. PP
6.-- I -.4i-p'�
,P 1\ ERIATE HILLS; I
BLOCK 4,LOT 5
�41:: /c K, HERI GE HILLS;
I
•6?) I PPROx t4 R1Ofl BLOGI 4.LOT 4
4144 TE Loc,A TsDN I
HERITAGE HILLS; CI I•
BLOCK 5.LOT 3 HERITA HILLS;
HERIATE HILLS. BLOC 4.LOT 3 I
I' , BLOCK 4,LOT 6 '
49. M SERVED BY WELL1 SERVED BY WELL
ON LOT 8A I ON LOT 8A
n,� mi .. iiiib
SEE DESIGN NARRATEIVE
`� REGARDING WELL CLASSIFICATION
*-,,,..466,
UL.....
! 4,
ft ."i Q AGE HILLS;
HERITAGE HILLS; v� = • 4,LOT 2
BLOCK 5,LOT 2 .P.--°
1S SER :DBYWELLI
• OT BA
-.4 -
le
wi BLOCK ,LOT SA
HERITAGE -ILLS;
H I ERVED B, WELL( BLOCK 4, OT 1
ON LOT BA
BELIEVED TO BE SERVED BY ,I i T
WELL ON BLOCK 4,LOT SA �..L
SE ED BY WELLHERITAG
BLOCK 5,OTS ON LOT BA
)4l
HUFFMAN ROAD
CONTOUR ACRES. CONTOUR ACRES: CONTOUR ACRES. 5 A
BLOCK 1,LOT 7 BLOCK 1,LOT 5 BLOCK 1,LOT 3 1'=loci
++rw\\\1ill,
GARNESS ENGINEERING GROUP Ltd °:• ..4'I
liV . .
•
---. CIVIL&ENVIRONMENTAL ENGINEERS •
•
3701 E TUDOR ROAD,SUITE 101.ANCHORAGE.AR 99507•PHONE(907)337-6179'FAX(907)338-3246'V4EBS1TE www gamessengneenng.con' • 1
PREPARED FOR: PHONE NUMBER: PAGE NUMBER. 11 1R : J• ,• - ness : 1
DEBORAH LYONAIS 345-1321 1 OF 2 ;.� C7-795 '� '•
PROJECT/LEGAL DESCRIPTION: DRAWN BY: I ♦
HERITAGE HILLS; BLOCK 4, LOT 7 D.J.G. •! 9 3 •� �
1.
TYPE OF WORK: DATE LICENSE ', FESS ♦;:♦♦
SEPTIC SYSTEM DESIGN UPGRADE SITE PLAN _ 9/27/2017 #AECC8B4 ������ J
r
rr
r
HERITAGE HILLS:BLOCK 4,LOT 4
I
GEG,Ltd.HAS A 8 PAGE SPECIFICATION
DESIGN CRITERIA: LETTER THAT PERTAINS TO THIS DESIGN.TO NOTE:THE CONTRACTOR
NUMBER OF BEDROOMS:2 OBTAIN A COPY OF THE LETTER CONTACT SHALL HAVE THE NORTH&
GALLONS PER DAY(GPD):300 GEG.BY PROCEEDING FORWARD WITH THIS WEST LOT LINES,AND ALL WELL
PERCOLATION RATE/S:8 MI WINCH INSTALLATION,THE ENGINEER,WELL DRILLER,
PROPOSED APPLICATION RATE:0.8 _CONTRACTOR AND PROPERTY OWNER AGREE RADII FLAGGED BY A
MINIMUM DAINFICA SQ.FT.:375 FT' THAT THEY HAVE READ THESE REGISTERED LAND SURVEYOR
SPECIFICATIONS AND AGREE TO ACCEPT THE PRIOR TO CONSTRUCTION.
TERMS AND CONDITIONS OUTLINED.
DRAINFIELD DESIGN:
MAXIMUM DEPTH:13 FEET i
WIDTH:2.5 FEET t
LENGTH:35 FEET X11 HERITAGE HILLS;BLOCK 4,LOT 3
EFFECTIVE:5.5 FEET
-- ACTUAL SQ.FT.:385 FT'
•
r
' EXISTING \ I
I •r-EIEDROON HOUSE \1 /
HERIATE HILLS:BLOCK 4.LOT 6 /
•,' '.
..
`i ` /
1..\\ \
Y
•4! .a
EXISTING DRAINFIELD ":'.;,
TO REMAIN IN PLACE •• a APPROXIMATE LOCATION OF 1996 T H.BY ROBERT C.COWAN,
I \ - '. y P.E.PER 1996_INSPECTION REPORT IN MOA RECORDS
4" ;+% :% ` EXISTING 1000 GALLON SEPTIC TANK TO BE
=, �T �= S EXCAVATED AND THE VOID FILLED WITH DRAINROCK:
SEE DESIGN LETTER AND WAIVER REQUEST
10'WAIVER •• i i APPROXIMATE LOCATION OF ABANDONED
8, I REQUEST,, . 'S i •_ SEEPAGE PIT PER ROBERT C.COWAN
,-u MT O �-- INSPECTION REPORT IN MOA RECORDS
1.5 FOOT WAIVER REQUEST 10+ `RS.%
hwitih.... f5'+ 1yj�
11_P_A•B/r_,t PROPOSED 1000\\ GALLON STEEL
10% `
❑ I EXISTING 2 SEPTIC TANK WITH DOUBLE
w BEDROOM �C/O'S BEFORE AND AFTER TANK ```
o HOME J APPROXIMATE LOCATION
f / OF EXISTING SEWER LINE
Ct O I / DECK
/ INSTALL FCO IF ONE HERITAGE HILLS;BLOCK 4,LOT 2
/ l r IS NOT PRESENT o
/ �So
/
r
r5 10% 1
1 $o FORMER CLASS"C"WELL
O r (NOW PRIVATE)THAT IS
% i BELIEVED TO SERVE LOT 7
' &6 OTHER LOTS
_ I I 10'UTILITY EASEMENT
/LILT r' 1
r
r
1
I 100'WELL RADIUS
1
M ,1 1
G4 I
I
1
I
1
1if;1\1
I HERITAGE HILLS;BLOCK 4,LOT 8A
WATER LINE TO BE 1
•-- PROFESSIONALLY LOCATED PRIOR
TO CONSTRUCTION TO ENSURE % �1 SCALE:
SEPERATION DISTANCE TO
EXISTING SEWER SERVICE LINE ` 1"=40'
* •
GARNESS ENGINEERING GROUP,Ltd ; �• ••: 11 - - • '•
CIVIL&ENVIRONMENTAL ENGINEERS •
3701 E TUDOR ROAD.SUITE 101•ANCHORAGE.AK 99507'PHONE(907)337-6179•FAX(907)339 m 3246'WEBSITE www garnessengmeering Co ..If
•
PREPARED FOR: PHONE NUMBER: PAGE %/V:t^ y Afi\t?SS /
•
DEBBIE LYNOAIS 345-1321 2 OF 2 I4S . CE)79 3 .•'•
PROJECT/LEGAL DESCRIPTION: DRAWN BY: 42 a
��1 j I 13./C.,HERITAGE HILLS; BLOCK 4, LOT 7 D.J.G. �1+'c j• •''••••• ••
ESS‘� ,
46.
TYPE OF WORK: DATE 444LICENSE •\i>♦11� «
I,•'
SEPTIC SYSTEM DESIGN UPGRADE 10/11/2017 #AECC884 PROF_ i
Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: ~ q ~ 0';~'-~7 PID Number: Oi ~ - '~ ~Z ~
Name: ~ ~opF~TT Wastewater System: D New ~ Upgrade
Address: ~ ~
~, ~-~ ~TZ~ .~ ~,~. ABSORPTION FIELD
Phone: ~.. ~ INo. o~edr°°ms: ~DeepTrench ~ Shallow Trench ~Bed ~Mound ~Other
Total Depth from original grade:
LEGAL DESCRIPTION S°ilRating: O.~ GPD/Sq. Ft.
Subd[v~ion: Depth to pipe boRom from original grade: Gravel depth beneath pipe
Township: ~ ~ Range: .~ Section: ~ Fill added above originaIo grade: Ft. Gravel Length: *~ ~ Ft.
I
Gravel width: Number of lines: Distance baleen lin~;
WELL: Cx,5~,~ew D Upgrade / ~.~t Ft. I ~ Ft.
Classification (Private, A,B,C): Total ~ ~ed To: ~Total absorption area: Pipe material:
Driller: ~ Date Drilled: Static Water Level: Installer: Date installed:
PM Ft. Ft.
SEPARATION DISTANCES ~s~mi~ ~ Holding D S,T.E,P.
To Septic Absorption Lift Holding 3ublic/Private Manufacturer: Capacity in gallons:
From Tank Field Station Tank Sewer Lines ~ ~ ~ ~ ~O
~. i ' ~ Material: Number of Compa~ments:
su~c~ -- LIFT STATION
LineL°t Jli &~ ~ i ~ ~ ~ Size in gallons: Manufacturer:~
~ "Pump on"~" level at: High water alarm at:
Foundation j ~ ~ ~ ~
Cu~ainDrain " - ~ ,~l ~, K~{ ~'~ ~od~chi~l I~pections pedormed by:
Remarks: BENCH MARK
Location and Description:
Inspections pedormed by: iJo~q ~agie River Loop Road, ' ..........
Department of Health and Human Se~ices approval ~,,;~,.....<:.. ,,
Reviewed and approved by: ) Date:/~ - ~- ~'~'" " ' '~
72-013 (Rev. 9/91) MOA 25
Permit No.
SW960567 Page 2 of 2
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
LegalDescription: LOT 7, BLOCK 4, HERITAGE HILLS S/D PIDNo.: 015-221-29
PARKING AREA
IEW 'lNG
SEPTIC
AND
100'
RADIUS
Ld
1000 GAL.
10' UTIL
SCALE
1" =40'
ST1
NIgW
1000
SEPTI~
ST2
SAL
[NAL GRADE ---~
CO1 = 95.2'
C02 =
CO¸
CO;
NO
72-013 A (Rev. 9/91) MOA 25
= 101.3'
·
FOUND
3.8' B.O.H.
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW960367
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:PROFFETT JOHN M
OWNER ADDRESS:5201 HUFFMAN RD
ANCHORAGE, ALASKA 99516
DATE ISSUED:il/25/96
EXPIRATION DATE:il/25/97
PARCEL ID:01522129
LEGAL DESCRIPTION:
HERITAGE HILLS BLK
4 LT 7
LOT SIZE: 15500 (SQ. FT.)
NUMBER OF BEDROOMS: 2 THIS PERMIT: 2
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80) .
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY: ~~f ~~
DATE: //
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER&WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL &
MECHANICAL
INSPECTIONS
ON SITE
W~TEWATER
DISPO~Ak SYSTEM
DESIGN
ROBERT C. COWAN, RE.
ROBERT A. SHAFER, RE.
October 6, 1996
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
P.O. Box 196650
Anchorage, AK. 99519
REFERENCE: Lot 7, Block 4, Heritage Hills Subdivision
Request you issue of a permit to upgrade the septic system
serving the existing %~o bedroom house on the referenced
property. A waiver is requested from the proposed trench to
the North and West lot lines at i foot.
A waiver request for the Class "C" well located on Lot 2,
Block 5, Heritage Hills S/D is being requested from
A.D.E.C. concurrent with this request under seperate cover.
A test hole was excavated and percolation test performed in
the area of the proposed upgrade. The approximate location
of the test hole is located on the attached site plan.
At the time of excavation no water was
after seven day ground water monitoring,
tube was found to be dry.
Attached is the proposed upgrade design.
encountered and
the monitoring
This property is served by a Community Water System.
We do not anticipate any adverse effects on neighboring
wells, septic systems or drainage patterns by the
installation of the proposed septic system.
If you require additional information, please contact us.
Sincerely,
Robert C. Cowan, m. ~..
RCC/gk
MUNICIPALITY OF ANCHoklAGE
ENVIRONMENTAL SERVICEs DIVISION
OCT 11 1995
RECEIVED
Enclosure
17034 NORTH EAGLE RIVER LOOP" SUITE 204" EAGLE RIVER, ALASKA 99577
~4::ALE
SITE PLAN I
F--
DESIGN
Ti~ACY I~OAD z~og
0
EXISTING
2 BDRM
HOUSE
m
--4 10' UTIL, ESMT
.:~
Z
~0~
DETAIL PROFILE
SCALE
TO BEDROCK
~':FO4"G ROU N D
WATER '
t 5' DEEP
, 'I" = 50' DESIGN __DETAIL
TRACY ROAD
~~N EXISTING
~ ~ ~ HOUSE
o ~ >~-- ~--
~ oc
~ ~ ........
/
/
/
~ = 30'
DESIGN
DETAIL
TRACY ROAD
EXISTING
2 BDRIVl
HOUSE
10' UTIL, ESMT.
m
Z
m
ROBERT C. COWAN, P.E.
ROBERT A. SHAFER, P.E.
ON-SITE WASTEWATER DISPOSAL SYSTEM ClVILENGINEERS
(907) 694-2979
CONSTRUCTION PRACTICES FAX(907) 694-1211
and
MATERIAL SPECIFICATIONS
STRUCTURAL &
MECHANICAL
iNSPECTIONS
HEALTH^UmOR~TY REFERENCE: Lot 7, Block 4, Heritage Hills Subdivision
APPROVALS
October 6, 1996
GENERAL:
1. The scope of this project includes the installation of
SEWER&WATER
~IN~TENSIONS a 1000 gallon septic tank and a leachfeild trench to
serve the two bedroom residence located on the
referenced property. The existing septic tank and the
existing crib are to be excavated, pumped, crushed,
S~VER&W^TER and abandoned completely.
INSPECTION
2. Construction shall be in accordance with the approved
site plan and design drawings, Municipal permit with
any special provisions or conditions, and all
ENGINEERtNGSTUDIES applicable State and Municipal Wastewater Disposal
AND REPORTS Regulations.
3. The contractor shall be responsible for obtaining any
necessary underground utility locates.
WELL INSPECTION
& FLOW TEST
4. Unless specifically agreed otherwise, the property
owner shall be responsible for final grading areas
subsequently depressed from soil settling.
SITE PLANS
5. Contractors installing wastewater disposal systems
must be certified by the Municipal Health Department
for system installations. Owners installing their own
systems must also receive prior approval from the
ROADOES,GN Municipal Health Department.
~EPTIC TANK INSTAL.LATION:
SOILTEST
1. A septic tank ';s to be constructed by a certified
septic tank manufacturer. Construction shall include
two 4" cleanouts for pumping access.
PERCOLATION
TEST
2. The septic tank shall be sufficiently bedded to
prevent settling or shifting of the tank.
3. Ail standpipes on the septic tank shall extend a
minimum of 12 inches above final grade.
ON SITE
WASTb~NATER
OISPOSALSYSTEM
DESIGN
17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577
Page Two
Lot 7, Block 4, Heritage Hills Subdivision
October 6, 1996
e
Se
Septic tanks installed with less than 4 ft. of cover shall
be insulated.
A foundation cleanout shall be installed one to four feet
from the building foundation. In the line between the tank
and the leachfield there shall be two adjacent cleanouts
(unless an effluent pumping system exists within the septic
tank). These cleanouts shall be located on undisturbed
soil not more than 10 ft. from the tank. The first
cleanout, in line, shall be to clean toward the leachfield.
The second cleanout shall be to clean toward the septic
tank.
Final grading over the septic tank shall be such that a
positive slope exists away from the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensions shown on the
design. The bottom of the excavation shall be within 2
inches of level. If the sidewalls of the excavation become
smeared, they must be raked or scratched (ruffed-up) before
gravel (sewer rock) placement.
Once the gravel is installed~ the distribution pipe is to
be installed level with the perforations faced downward.
Gravel is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
A silt barrier must be installed between the final gravel
layer and the native soil backfill. Ensure the silt
barrier covers the entire gravel surface before placing
backfill.
e
Monitor tubes shall be of four (4) inch diameter,
installed approximately in the locations shown on the
design, and extend a minimum of 12 inches above final
grade° The portion of the monitoring tube extending
through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe. This is
equivalent to the effective depth of the gravel as noted on
the design.
Page Three
Lot 7, Block 4, Heritage Hills Subdivision
October 6, 1996
Backfill over the final gravel layer must not be less than
twenty-four (24) inches. Insulation must be installed when
the backfill depth is less than thirty-six (36) inches.
The finish grade over the trench must be mounded to prevent
the formation of a depression after settling.
MINIMUM MATERIAL SPECIFICATIONS:
Any septic tank proposed for installation must be
constructed by a Municipally approved septic tank
manufacturer.
The following pipe materials are approved for use in septic
system installations in the Municipality of Anchorage:
Type of Pipe
Perforated Solid
Cast Iron
ASTM D3034 (PVC)
ASTM F810 (HDPE)
ASTM D2662 (ABS)
Yes Yes
Yes Yes
Yes No
Yes Yes
Use of a type of pipe other than listed above must be
approved by the inspecting engineer.
Insulation shall be at least 2" thick extruded direct
burial polystyrene (Dow Chemical Company Styrofoam HI or
equal).
Septic tank inlets and outlets shall be fitted with
watertight couplings (Caulder, Fernco, or equal).
A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N,
or equal) must be installed between the final leachfield
gravel layer and the native soil backfill.
Ail leachfield gravel (sewer rock) shall be 0.5"-2.5"
screened gravel with ].ess than 3% passing the 9200 sieve.
7e
When sand is being used as a filter material, its gradation
specifications must conform to current M.O~A. or D.E.C.
requirements, which ever applies~
Page Four
Lot 7, Block 4, Heritage Hills Subdivision
October 6, 1996
INSPECTIONS:
Typically there will be a minimum of three (3) inspections
required during the installation of the wastewater disposal
system. These inspections will occur as follows:
e
The first inspection must be conducted after the
excavation of ditches, pits, trenches, or beds and
before the installation of any gravel. A septic tank
may be set in place, but may not be backfilled before
this inspection.
The second inspection must be conducted after the
placement of the silt barrier, gravel, distribution
lines, standpipes, cleanouts, and insulation, but
before the placement of any other backfill.
The final inspection is to occur upon final grading of
the property.
Often there will be more than these 3 inspections required.
Especially with the installation of multiple trenches, sand
filters, pressurized distribution systems, etc. Thus, the
inspecting engineer is to be contacted at least 24 hours prior
to the start of construction. If necessary, a pre-construction
meeting will take place on-site. The inspecting engineer will
not coordinate, direct or control in any way the contractors
activities.
The owner shall contract with the contractor to perform the work
outlined in these specifications and plans and in accordance
with the attached M~O.A. permit. There will be no contractual
arrangement existing between the contractor and S & S
Engineering. S & S Engineering shall be the owner's
representative and will inspect the work as stated above to
document the contractors activities. Final acceptance of the
contractors work rests with the owner and the M.O.A.
Page Five
Lot 7, Block 4, Heritage Hills Subdivision
October 6, 1996
S & S Engineering shall have no liability to the owner or to
others for acts or omissions of the contractor or any other
persons performing work on this project or the failure of the
contractor to carry out the work in accordance with these
construction documents. S & S Engineering's inspecting engineer
will not be responsible for the construction means, methods,
techniques, sequence, procedures or the safety precautions
incident to this project.
CONTRACTOR/INSTALLER
PERFORMED FOR: ~J' 0 ~j~/
LOT'
LEGAL DESCRIPTION:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
r: ~.,~- ROBERT C. COWAN
~,.'"~,'J"-.. CE - 8801 /~";.
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
2O
IV~L
~ 0
jcl/
WAS GROUND WATER J~ O
ENCOUNTERED?
IF YES, AT WHAT ~
DEPTH?
Depth to Water After /~//~
Monitoring? Dr°'"'/ Date: ,/0 ~
SLOPE SITE PLAN
I
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN /O ~-~. FTAND il ~/3_________________~. FT
COMMENTS
PERFORMED BY: 1)0;f4 Eagle River Loop Road No. 204 ' ~ ~ ' ' '
ACCORDANCE WI'i~._I~eT'~i~'~L~[~L GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
Parcel I.D. #
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
GENERAL INFORMATION
Complete legal description
Lot 7;
Block 4; Heritage Hills Subdivision
Location (site address or directions)
Tracey Road
Anchorage, AK
Prope~y owner John & Hilde Proffett Day phone 345-5480
Mailing address P.O. Box 772066 Eagle River, AK 99577
Lending agency
Mailing address
Agent
Address
Alaska USA Federal Credit Union
Day phone 786-2726
Day phone
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS:
TYPE OF WATER SUPPLY:
Individual well
Community well
NOTE:
Public water
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
NOTE:
xx~
Public sewer
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system~
72-025 (Rev. 1/91) Front MOA #21
STATEMENT OF INSPECTION BY ENGINEER.
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm S & S ENGINEEEING
i~034 Eagie ~,iver Loop ~oad No. ~0~t Phone d"c/
Address Eagle River, ~Alaska 99577,
Engineer's signature '~--~Z. ~"(~-- Date
DHHS SIGNATURE
Approved for ~-
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Additional Comments
Date ./2- 7- ~'~'
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-O25(Rev. 1/91) Back MOAIffZ1
of Anchorage DEC; 0
Municipnlity
DEPARTIVIENT OF HEALTH & HUIVlAN SERVICES
Environmental Services Division R [ C ~
825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744
Legal Description:
A. WELL DATA
Well type
Log present (Y/N)
Health Authority Approval Checklist
Total depth
San!
'~4. ~ If A, B, or C, attach ADEC letter. ADEC water system number ~.
Date completed. ~
C,a.se~ Casing height (above ground)
FROM WELL LOG
/
Date of test /
//
Static water level
Well production
WATER SAMPLE RESULTS:
Coliform 0 Nitrate
Date of sample: I i -
B. SEPTIC/HOlDING TANK DATA
Date installed it-Z"i"-"~, Tanksize
Foundation cleanout (~N)
Date of Pumping
Wires properly protected (Y/N)
AT INSPECTION
g.p.m, g.p.m.
Collected by:
Other bacteria O
$ & S ENGINE~IN~
17034 Eagle River Loop Road, No. 204
Eagle River, Alaska
I ¢:~_~,,~ Number of Compartments ~ Cleanouts(~)N)
Depression (Y/~ ~ O High water alarm (Y~
Pumper '"~------~
C. ABSORPTION FIELD DATA
Date installed J ~ - 2 1 - c~ C Soil rating ~or ft2/bdrm) ~ .' ~ System type
Length ~ Width ~-. ~ ~
Gravel thickness below pipe 5o 5 Total depth
Effective absorption area ~'?,~ d Mon toring Tube present (~1). Y~$ Depression over field (Y~) ~j~ o
Date of adequacy test ~ F~.J Results (Pass/Fail) '-"-- For
Fluid depth in absorption field before test (in.); ~ Immediately after '"- gal. water added (in.):
Fluid depth ~ (ins) Minutes later: ~ Absorption rate = ~ _g.p.d.
Peroxide treatment (past 12 months) (Y/N)
If yes, give date
bedrooms
72-026 (Rev. 3/96)*
D. LIFT STATION ......
Date installed Size in gallons ._-.-
Manhole/Access (Y/N) "Pump~r~ "Pump elf"level at*
High water alarm level at* __~*Datum
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic/holding tank on lot
Absorption field on lot
Public sewer main
On adjacent lots
__.--.-----'"" Public sewer manhole/deanout
Lift station
SEPARATION DISTANCES FROM~HOLDING TANK ON LOTTO:
t
Foundation ~J I Property line ! I Absorption field
Water main/service line ~ot~ Surface water/drainage j OoI+ Wells on adjacent lots
,7j
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO:
Property line ,,4.,~,~ab Building foundation 'Z.Z, Water main/service line
Surface water 100! -t" Driveway, parking/vehicle storage area __
Curtain drain ~/~ Wells on adjacent lots
HAAFee $ ~E~r~:~.)
Date of Payment / ~-//'~ /~,,~'~
Receipt Number '~'~-- ~'7 ~/~
/
ENGINEER'S CERTIFICATION .;~ t~JN4~12,
I certi~ that I have determined thru field inspections and review of Municipal records th~~ x{tems are
in conformanc A'guideliaes in effect on this date.
Engineer's
Date / ~ /~/~
Waiver Fee $
Date of Payment
Receipt Number
72-026 (Rev. 3/96)*
DEPT. OF ENVIRONMENTAL CONSERVATION
ANCHORAGE WESTERN PUBLIC SERVICE OFFICE
555 CORDOVA STREET
ANCHORAGE, ALASKA 99501
November 18, 1996
TONY I~lv~vvr.~-'-', '"' .........
(907)269-7505
Mr. Robert C. Cowan, P.E.
S & S Engineering ,
17034 North Eagle River Loop, Suite 204
Eagle River, Alaska 99577
SUBJECT: Lot 7, Block 4, Heritage Hill Subdivision, Separation Distance Waiver
AWPSA Project Number 9721-DW-284~043, Review
Dear Mr. Cowan:
This letter is in response to the submittal received on November 4, 1996, in which you address
the concerns noted in my October 23, 1996, letter regarding the following separation distance
waivers:
Between a Class C Public System Source Well on Lot 2, Block 5 and the septic
tank on Lot 7, Block 4 from 150 feet to 107 feet.
Between a Class C Public Water System Source Well on Lot 2, Block 5 and the
soil absorption system on Lot 7, Block 4 from 150 feet to i04.5 feet.
We have completed our review of the submitted information which include a cover letter, soils
logs,, site plan, well logs, some geological data, and water quality analysis of the water from the
source well on Lot 2, Block 5. From our review, it appears the lesser separation distance could
provide the need treatment of the wastewater which is need to protect public health and the
environment. Therefore, in accordance with the provisions of 18 AAC 80.030, the above noted
separation distances are granted.
The following are requirements of the above granted waiver:
Verification that the vertical separation distance of four (4)feet between the lowest
part of the soil absorption system and the seasonal high ground water has been
meet. In addition, verification of the in-situ soils will need to be submitted to this
office.
Mr. Cowan 2 November 18, 1996
As-built drawings, under the stamp of a Professional Engineer (P.E.), needs to be'
submitted to this office within 90 days of completion of the project. The as-built
drawings will need to include a cross section of the soil absorption system.
This waiver will remain valid until the wastewater disposal system on Lot 7, Block 4 again
requires upgrading. If upgrading or replacement is necessary, due to the small lot size and the
high density of wastewater disposal systems, additional treatment to the waste stream will be a
requirelnent of any futurq waiver requests for this property.
This approval to construct does not imply the granting of additional authorizations, nor obligate
any federal, state, or local regulatory agency to grant the required authorizations.
Thank you for your cooperation and coordination with this Department. If you have any
questions, please do not hesitate to contact me.
S, incerely,
Environmental Engineer
cc: Jim Cross, P.E., MOA/DHHS
KKK/ph
Rick Mystrom,
Mayor
of Anchorage
DePartment of Health and Human Services
825 "U' Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
December 9, 1996
Robert C. Cowan, P.E.
S & S Engineering
17034 Eagle River Loop Road
Eagle River, Alaska 99577
Subject:
Waiver Request for Lot 7 Block 4 Heritage Hills Subdivision
Waiver Request #WR960055, PID #015-221-29, HA960529
Dear Mr. Cowan:
Your request for a waiver of the required 10 foot separation between an on-site
wastewater disposal system and a lot line has been approved. The waived distance is 1
foot from the north and west property lines to the absorption field.
This approval applies to the existing on-site wastewater disposal system lot line separation
only. Any future upgrade to the on-site wastewater disposal system will require all
separations be met or another approval from this department.
If there are any further concerns or questions regarding this waiver, please call our office
at 343-4744.
Sincerely,
Civil Engineer
On-site Services Program
DJR/Ijm: Proffett
k-~MUNICIPALITY OF ANCHORAGEmj
Department of Health and Human Services
On-site Services Section
Waiver Review Worksheet
WR# WR960055 PID# 015-221-29 HA#
Date Received: October 11, 1996
Legal Description: Lot 7 Block 4 Heritage Hills Subdivision
Engineer:
Permit #
Robert C. Cowan, P.E., S & S Engineering
17034 North Eagle River Loop, Suite 204, Eagle River, Alaska 99577
Applicant: John Proffett ~
Waiver Requested: Lot line waiver of 1 foot from the North and west lot lines
absorption field
Criteria: 1. Geology: Points:
A. Water Table
B. Soil Sorption
C. Permeability
D. Water Table Gradient
E. Horizontal Separation
TOTAL:
2. Special Conditions:
3. Other:
Waiver is Granted: ~ Waiver is NOT Granted:
List Conditions or Reasons for above: fRg ~6/N£F~£ ~-~/~p
Date: II-- /~--~
By:
Name of Reviewer
Rec #: ~\ I~5 Amount: $ ~ Date Paid:
DEPT. OF ENVIRONMENTAL CONSERVATION
ANCHORAGE WESTERN PUBLIC SERVICE OFFICE
555 CORDOVA STREET
ANCHORAGE, ALASKA 99501
TONYKNOWLE~ GOVERNOR
(907) 269-7505
October 23, 1996
Mr. Robert C. Cowan, P.E.
S & S Engineering
17034 Eagle River, Suite 204
Anchorage, Alaska 99577
RECEIVED
Municipality o~Anch~°ra~e ·
Dept. Health & Human ~8rvices
Subject:
Lot 7, Block 4, Heritage Hill Subdivision, Separation Distance Waiver,
Anchorage, Alaska, AWPSO Project 9721-DW-284-043, Review
Dear Mr. Cowan:
This letter is in response to your October 9, 1996 submittal in which you requested this
Department to waive the separation distance between the Class C Public Water System
on Lot 2, Block 5, Heritage Hill Subdivision and the proposed wastewater treatment and
disposal system on Lot 7, Block 4, Heritage Hill Subdivision from 150 feet to 100 feet. I
have completed my review of the submitted information, information in this office's files
regarding public water systems and wastewater disposal systems in the Heritage Hill
Subdivision, and our October 23, 1996 conversation, I have the following comments:
The Department has already granted similar waiver (150 feet down to 100 feet) between
the Class C Public Water System Source Well and the wastewater disposal system on Lot
2, Block 5. This waiver was granted based on the fact that the engineer proposed
additional treatment for the wastewater stream prior to being discharged. This makes the
review of your request very difficult. As we discussed on October 23, 1996, i have two
choices in regards to your waiver request. The first is to deny your request on the grounds
that for the subject Class C Public Water Source Well, the approved mitigating factor is the
requirement for additional treatment (treatment above what is provided in a septic tank) of
the wastewater stream. The second choice is to request additional information in
accordance with procedures outlined in 18 AAC 72.015(b)(2) and (3).
I believe that at this time my second choice is the proper way to resolve the concerns with
this waiver request. Please provide additional information to address the following items:
Describe soil classifications, groundwater conditions, surface topography,
geology, and any other environmental conditions that would assist the
department in establishing a lesser separation distance.
Mr. Robert C. Cowan, P.E.
October 23, 1996
Page 2
Include a set of plans of the proposed wastewater disposal system for lot 7
Block 4, the set of plans must include an accurate description and location
of potential sources of contamination, surface water, and existing or potential
drinking water sources in the area.
Information that should be used to address the two items noted above are either well logs
or well probe results from source wells located in Blocks 4 and 5 of Heritage Hill
Subdivision. Please include as accurate as possible distance mea. surements between the
source well on Lot 2, Block 5 and all components of the proposed wastewater disposal
system on Lot 7, Block 4.
Another reason the issuance of this waiver is diffic'ult is the fact that the lots in this
..subdivision were not designed to have on lot wastewater disposal systems and drinking
water systems as the final solution to wastewater and water concerns. It is obvious that
with the smaller lots, community water distribution and wastewater collection were the final
solution for wastewater and water concerns for this subdivision.
Thank you for your cooperation with this Department. If you have any questions, please
do not hesitate to contact me.
Sincerely, / ~
Keven K Kleweno, P.E.
Environmental Engineer
KKK/ph
cc: Jim Cross, P.E., MOA, DHHS,
DATE
,TIME ~ TIME TiME
3ATE DATE DATE
I NSP~~ INSPECTOR I NSP ECTOR
MUNICIPALI~ OF ANCHORAGE
ENVIRONMENTAL P~O~EC~ON
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
825 L Street - Anchorage, Alaska 99501
ENVIRONMENTAL SANITATION DIVISION
Telephone 264-4720
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
DIRECTIONS: Complete all parts on page 1, Incomplete requests will not be proce~ed, Please allow ten (10) days for processing.
1. PROPER~ OWNER ¢ PHONE
MAILING A~RESS
PROPER~Y RESIDENT (~f different from ~bove) PHONE
~. ~UY~R ~ PHO~
MAILING ADD~ES~
MAILING ADDRESS
MAILING ADDRESS - /
, ,
5. LEGAL DESCRIPTION
16. TYPE OFA[Sl~[~g[
~GLE FAMILY
MULTIPLE FAMILY
N~M~EH O~EEDROOMS
[] One [] Four
~ Two [] Five
[] Three [] Six
[] Other
7, WATER SUPPLY [] INDIVIDUAL*
COMMUNITY
[] PUBLIC UTILITY
*ATTACH WELL LOG. A well log is required for all wells drilled
since June 1975. For wells drilled prior to that date, give well
depth (attach log if available.}
8. SEWAGE DISPOSAL SYSTEM
~ INDIVIDUAL/ON-SITE**
[] PUBLIC UTILITY
/ ~'7~'-' 'YEAR ON-SITE SYSTEM WAS INSTALLED.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[~ SINGLE FAMILY E3 ONE [] THREE E~ FIVE E~ OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2. WATER SUPPLY
[] INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[] INDIVIDUAL/ON -SITE DATE INSTALLED
Connection Verified . INSTALLER
[]Septic Tank or [] Holding Tank .
Size: '~ ~ If Tank is homemade SOILS RATING
give dimensions:
TYPE OF TANK MANUFACTURER
TOTAL ABSORPTION AREA MATERIAL
4. DISTANCES Septic/Holding Tank Absorption Area Fewer Line Nearest Lot Line
WELL TO:
Absorption Area to nearest Lot Line
5, COMMENTS
[~*/~,PP ROV E D FOR ~ BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[] DISAPPROVED
DATE BY
72-010 (Rev. 6/79)
January 4, 1980
Ronald J. Hildebrand
Post Office Box 1063
Wasilla, Alaska 99687
Subject: Lot 7 Block 4 Heritage Hills Subdivision
Approval for your individual sewer and water facilities
can not be granted until the following items have been
completed:
(1) The water analysis report be delivered to this office
from Ch~ Lab, 5633 B Street, for our review.
(2) The septic tank pumped with a receipt submitted to
this office°
(3)
An adequacy test be perfommed on the existing leaching
area. This test will determine if the system is
adequate according to National Standards. A listing of
private fir~s performing the test is enclosed.
If there are any further questions, please contact this office
at 264-4720.
Sincerelyt.
Robert C. Pratt~ R.S.
Associate Specialist
R~P/lJw
National Bank of kAlaska
Pouch 7-025 99510
Doug Taylor
% Jack White Company
3201 C Street 99503
January 11, 1980 R~i No. 051001
Ron Hildebrandt
P.O. Box 1063
Wasilla, Alaska
Re: Adequacy Test on Existing Sanitary Sewer System; Lot 7, Block 4,
Herritage Hills Subdivision, Anchorage, Alaska
Dear Mr Hildebrandt:
Per your request of January 3, 1980, we conducted a test of the sanitary
sewer system on the above described property.
During this test the liquid level in the septic tank was monitored as water
was added to the system. The measurements are summarized in the following
table:
Time
Liquid Level Below Top
of Standpipe
Total Gallons
Added
2:30 6.1' 0
2:35 6.05' 25
2:41 6' 50
2:47 5.9' 75
2:53 5.7' 100
3:03 5.9' 125
3:05 6.1' 125
The meter used
had previously
during the test was a Rockwell 5/8" standard water meter which
been calibrated by R&M Consultants, Inc.
ANCHORAGE FAIRBANKS JUNEAU VALDEZ WASILLA
January 11, 1980
Ron Hildebrandt
Page -2-
If the 2 bedroom residence on the property is to house 4 people, the average
load on the system can be expected to be 300 gallons per day or .21 gallons
per minute. During the test, the system accepted 125 gallons in 35 minutes.
This indicates an average effluent acceptance rate of approximately 3°6
gallons per minute at the time of the test.
We can therefore conclude that the system is disposing of effluent at an
adequate rate for a 6 bedroom residence.
We appreciate this opportunity to be of service to you. Please contact us if
you have any questions concerning this test or if we can be of additional
service.
Very truly yours,
R&M CONSULTANTS, INC.
Staff Geologist
ERR/GAS/dj/AT&SI-P
Project Manager