HomeMy WebLinkAboutLA FORET LT 5 Municipality of Anchorage Page I of ~ DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: S'Lx,z ~j~OC-.) ~ e../ PID Number: 0 ! 7.3' ¥ Name:~A, It? ~ /'r~/'Ay /~e~ce~ Wastewater System: [] New [] Upgrade '" Total Depth from original grade: LEGAL DESCRIPTION S°il Rating: ~, g GPD/Sq, Ft. I ~' Lot: Block: Subdiv~ion: Depth to pipe bottom from odginal grade: Gravel depth beneath pipe Township: Range:, Section: ,- Fill added above original__ grade: Ft. Gravel length: ~ ~ Ft~ WELL: ~JT ~ New ~ Upgrade Gravelwidth: Number of lines: ~stancebelweenlines: ClassifiCation (Private, A,B,~'): Total ~epth: Cased To: Total absorption area: Pipe material: ~_~ Driller: Date Drilled: StaticWaler Level: Installer: SEPARATION DISTANCES ~ s~pt~ ~ Ho,ding ~ S.~.~.~. To J Septic (N~Abs° Ilo Lift Holding Public/Private Manufacturer:~ Capacity in gallons: ' '~ Number of Compartments: su,~ LIFT STATION ~.~, ' ' Manufacturer: Lot Size in gallons: Foundation ~ ~ ~ -- -- ~ "Pump on" level at: "Pump orr, level at: High water alarm at: Curtain Pump Make & Model Electrical Inspections performed by: Drain -- -- .... I Inspections performed by: Ff~/~/ %rca %¢c Dates: 1st ~/¢¢/9( .t,,,:,,~,;,~... ................. 2nd Department of Health and Human Services approval ': ",~ ~ c~-:;.:~: : ,~- Reviewed and approved by: ~ Date: ~- ~ ~ "~' ~ ........ '" '~ 7a-013 (Rev. 9/91 ) MOA 25 PERMIT NO: SW960044 PAGE 2 OF 3 PID NO: 01734205 WELL SWING TIES: FROM: TO: COR."A" COR."B" S.T.C.O."F" 51.5' 24,5' S.T.C.C. "G" 56,5' 28' DBL. C.C. "H" 58' 30' VALVE "J" 58.5' 32' TR. C.O, "K" 97.5' 62' TR. M,T. "L" 97.5' 59.5' TR. C.O,"M" 103.5' 54.5' TR. M.T. "N" 95' 49.5' TR, C.C. "O" 82' 40' NEW 1000 GAL. SEPTIC TANK VALVE 3 BDRM -lOUSE "F" %'% 'H" %. /% / / / ',, / ",, -,, %. C.O. NEW 42' LONG SOIL ABS. TRENCF W. 7.6' GRAVEL BELOW DIST. PIPf LOT 5, LA FORET S/D SEPTIC SYSTEM UPGRADE AS-BUILT INSPECTION REPORT FLATTOP TECHNICAL SERVICES 14530 ECHO STREET ANCHORAGE, ALASKA 99516 SCALE: 1" = 30' -0" DRAWN BY TFM MAY, 1996 PERMIT NO: SW960044 PAGE 3 OF 3 PID NO: 01734205 ORIG. GND ELEV. 98.3' INV 94.8' 1000 GAL. SEP. TANK 94.5' INV. 93.8' BOT. TR. ELEV. 86.3' T.H. #2 BOT. M.T. ELEV. 80.3' DRY 4/15/96 BOT. TR. ELEV. 86.3' LOT 5, LA FORET S/D SEPTIC SYSTEM UPGRADE PROFILE AS-BUILT INSPECTION REPORT FLATI'OP TECHNICAL SERVICES 14530 ECHO STREET ANCHORAGE, ALASKA 99516 NOT TO SCALE DRAWN BY TFM MAY, 1996 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW960044 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:REECER PHILIP E OWNER ADDRESS:13351 GINPOLE CIR ANCHORAGE, ALASKA 99516 DATE ISSUED: 4/04/96 EXPIRATION DATE: 4/04/97 PARCEL ID:01734205 LEGAL DESCRIPTION: LA FORET LT 5 LOT SIZE: 50915 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD SYSTEM ALL CONSTRUCTION MUST BE lin ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AA072) AND DRINKING WATER REGULATIONS (iSAACS0) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS RECEIVED BY: ~ ISSUED BY: ~~~ DATE: CIVIL & ENVIRONMENTAL ENGINEERING., ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 Mm'ch 27, 1996 ANCHORAGE, ALASKA 99516 M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dem' Sirs: The purpose of this letter is to provide the required design nan'ative in suppml of our application for a permit to upgrade the wastewater disposal facilities on Lot 5, La Foret S/D, located at 13351 Ginpole Circle. Soils logs, perc test results, a site plan, design drawings and specifications are enclosed for yom' review. The proposed system will be constructed in the vicinity of test hole # 2. As can be seen from the soil log, the native material between 4' mid 18' is a somewhat silty sand with a measured perc rate of 4 minutes per inch. Using a slightly conservative soil application rate of. 0.8 gpd/sq, ft., this 3 bedi'oom residence requh'es a total absorption area of 3(150)/0.8 = 562.5 squm'e feet. The proposed 41' long n'ench with 7' of sewer gravel has a total absmption m'ea of 574 square feet. The topography of the lot in the m'ea of the proposed construction slopes towm'ds the southwest at approximately 3% The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any significant impact on rese~wed space- surface and subsurface, or on drainage. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. ZeE 100, EXISTING 1000 GALLON? SEPTIC TANK' SEPTIC SYSTEM HOUSE 'x \ INSTALL DBL. C.O, AND "BULL RUN" DIVERTER VALVE LOT 6 LA PORET S/D LOT 5 LA FORET S/D T.H. x, T.H. x, \ , CONSTRUCT 41' LONG , SOIL ABSORPTION TRENCH WITH 7' GVL. BELOW PIPE PRIVATE WELL TRACT A SWENSON S/D LOT 5, LA FORET S/D SEPTIC SYSTEM UPGRADE SITE PLAN FLATFOP TECHNICAL SERVICES 1 INCH = 50 FEET 14530 ECHO STREET DRAWN BY TFM ANCHORAGE, ALASKA 99516 MARCH, 1996 NOTE: THIS IS NOT ASURVEYED PLAT. ALL LOCATIONS SHOWN ARE APPROXIMATE. INSTALL "BULL RUN" ~ / DIVERTER VALVE ~ ~'~_.~EXISTING lOOO GAL. TO ORIG. II % SEPTIC TANK A ~ II-x 4" ASTM D-3034 ..,O, C.O. ~ ---"A~lm~ 4 lrlrlrlr~M.T. --~/ CONSTRUCT NEW 41' LONG SOIL ARS. TRENC~ W. 7' - 0" SEWER GRAVEL BELOW DIST. PIPE. PLAN VIEW SCALF_: 1" = 10'- 0" TUBE D BACKFILL 12" ,RIGINAL GROUND FABRIC ASTM F-810 PERF DIST. PIPE 1/2" - 2 1/2" SEWER GRAVE; OF EXCAVATION SECTION "A - A" 1" = 5'- 0" LOT 5, LA FORET S/D PROPOSED SEPTIC SYSTEM PLAN AND CROSS-SECTION FLATTOP TECHNICAL SERVICES 14530 ECHO STREET ANCHORAGE, AK, 99516 SCALE: AS SHOWN DRAWN BY: TFM MARCH, 1996 Flattop TechnicaI Serv~es 14530 Echo Street, Anchorage, AK99516 Phone (907) 345-1355 Lot 5, La Foret S/D 13351 Ginpole Circle Wastewater disposal system installation Specifications 1.0 General: 1.1 The scope of the project consists of consU'uction of a 41 foot long soil absorption trench with a total of 7.5 feet of sewer gravel. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these &'awings may be allowed or required by the engineer conducting the inspections. All construction procedm'es and material specifications shall conform with Municipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessm3, utility locates, and to work around any bmSed utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper di'ainage is achieved after settlement and that there m'e no residual depressions. Insofm' as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all m'eas disturbed by the consn'uction. 2.0 Septic Tank: 2.1 The existing 1000 gallon septic tank may be retained in smwice, only if it's structural integaity has been verified by the inspecting engineer, and if it has functional cleanout pipes with ah'tight caps, allowing pumping access to each compartment. Any existing septic tank or seepage pit which is not retained in setw~ce must be properly abandoned by thoroughly pumping, removing the top and backfilling with soil. 2.2 If it is required, a new 1000 gallon, 2 compm'tment septic tank shall be Municipally approved and shall be set level on undistm'bed soil. Each compartment shall be equipped with a watertight manhole cover and a 4" cleanout. If the tank is buffed less than 4 feet, it shall be insulated with 2 inches of approved burial type, rigid insulation. 2.3 All pipe connections to the tank shah be equipped with waterproof mechanical couplings. The waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and the waste line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A "Bull Run" diverter valve shall be installed downsn'emn of the septic tank allowing reconnection to the original soil absorption trench at a future date, if desired. A double cleanout shall be installed within 5 feet downstream of the diverter valve. 3.0 Soil absorption system: 3.1 The soil absorption system shall be constructed by excavating a 41 foot long trench to a depth of 11.5 feet below original ground level in the vicinity of test hole #2. 3.2 The bottom of the excavation shall be level. Any compacted or smem'ed surfaces shall be raked to allow proper infilt~'ation. 3.3 A total of 7.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with the perforated distribution pipes laid level such that the pipe inverts a'e no less than 7.0 feet above the bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the 4/200 sieve. 3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 3.5 Approved filter fabric shall be placed over the enth'e top sm'face of the sewer gravel. A minimum of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less than 3 feet, two inches of rigid, burial type insulation is to be placed over the entke top surface of the gravel, in addition to the filter fabric. 3.6 The top surface of the cover matefial shall be raised a minimum of 12 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contom's. Fill slopes shall be no steeper than 3:1. 3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have the site finish graded after tbe backfill material has stabilized, and for placement of adequate topsoil and seed to promote rapid revegetation of all m'eas disturbed by the consU'uction. 4.0 Inspections: 4.1 A minimum of 4 engineering inspections will be required during the course of the project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative sm'face to ensure that it is level and at the fight elevation, and confo~xns with the soil test infmrnation, (3) after the sewer gravel is in place and the disu'ibution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and grading is complete. If a new septic tank is requh'ed, it will entail one inspection after it is set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 4.2 The installer shall coordinate the thning of the inspections with the engineer sufficiently fro' in advance to ensure the availability of the engineer. TEST HOLE Cf ! LEGAL DESCRIPTION: DATE PERFORMED: PFRFORMED FOR: DEPTH (feet) Pt, Lot 5, La Foret S/D FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST March 19, 1996 Philip and Kathy Reecer SM Reddish sandy loaln ML Gray sandy silt Some gravel, cobbies aed boulders Dry. does not smear Iacreusingly dense aad cohesive below 10' SLOPE COMMENTS: Deplh to Groundwater Date ~I0 GROUNDWATER 3/19/96 MONITOR TUBE DRY 3/26/96 Clock Net Time Percometer Net Drop Date Reading Time (minutes) Reading (inches) SM Silty sand 3/19 l'2~P~E~Eak 1 t:46 -~2'/~,/~ 11:35 26 15/Ih 12:ll 26 7/16 12:38 26 1/16 SW Clean medium saed 12:53 15 25~//8 3/16 PERCOLATION RATE >60 (minutes/inch) PERO ROLE DIAMETER 6" TEST RUN BETWEEN 6.0 FTAND 6.5 FT Silty material is not suitable for conventional soil absorption system. PERFORMED BY FLATTOP TECHNICAL SERVICES. [ '~,4.~, ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~'//~ 7 ,/~" Il'EST HOLE # FLATTOP TI=CHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: Lot 5, La Foret S/D DATE PERFORMED: March 19, 1996 PERFORMED FOR: (feet) 1- Philip and Kathy RReecer Pt. SM Rexldish sandy loam ML Gray sandy silt SP/SM Somewhat silty sand Dry, easy digging Gravelly smd found above SLOPE Depth to Groundwater Date NO GROUNDWATER 3/19/96 MONITOR TUBE DRY 3/26~96 SITE PLAN i i ! i3% ! ! : : COMMENTS: Clock Net Time Percometer Net Drop Date Reading Time (minutes) Reading (inches) -3/19 Presoak Start I: 19:26 23 3/8 #1 1:24:26 5 22 0/16 1 3/8 Add water 1:25:30 23 3/8 _ #2 1:30:30 5 22 1/16 1 5/16 Add w,~iar 1:30:50 23 1[2 #3 1:35:50 5 _ 22 3/16 1 5/16 PERCOLATION RATE 4 (minutes/inch) PERC HOLE DIAMETER 6" TEST RUN BETWEEN 8,0 FTAND 8,5 FT Material ia perc test hole was somewhat siltier than typical of stratum. Recommend basing desiga on perc rote of 6 - 15 rain/in. PERFORMED BY FLATTOP TECHNICAL SERVICES. I ,t.~_~_~~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES iN EFFECT ON THiS DATE. DATE: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME MAILING ADDRESS LEGALDESCR,PT,O . 5 L--4. ¢¢--¢ Ne. oF BEDROOM~ / ~ Dwelling ~ PHONE [] UPGRADE DISTANCE TO: Manufacturer (~ Absorption area Liq. ca Inside length IF HOMEMADE: Well Dwelling DISTANCE TO: Manufaotur DISTANCE TO: Top of tile to finish grade Length Width Mate/-iel £ Width Foundation Nearest lot line Total length of lines Material beneath tile Depth Building f ou nda ' on~.~...~ Trench width ,.~...~_ inches Total ef fect~.~u, p~ *d~eCrost lot line PER M IT NO.~(.~ ~.~ ~ No. of xmpartments Liquid dept~h PERMIT NO. PERMIT NO. oo 5-.9-3 Distance between lines Total effective absorotion area 70(.'7 PERMIT NO. Depth Driller Distance to lot line PERMIT NO. DISTANCE TO: Buildin§ foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS SOIL TEST RATING I NST/)~t?L ER ') DATE LEGAL 72-013 (R¢¢,/3/7~) / I DEF'FIF.':TMENT C,~' HEFILTH FIND E'N' "IF._HflEHrHL~ , ...... r-"OT'ECTION ,:,c.,~ '" L I~E.F,MIT NO. ,' R ~ JEk. H,',E, EE.~ G I NF'OLE RE:,. LOT 5 L~FORET SUB : 2E;4--d-72EH HZ) t~-~ .... .:~=; Z '"T" E: "_.-% EZ II..-~ E HF F L. i L.O ~. Fl"l" I ON LEGFIL. LOT =, I..'.E T'¢F'E L]F '.'".';OIL HE,_-",I_IRFTIUN ..,,,.. " :[S =,'r :,TEl I : TF.:ENCH F' E: IF~: I1'.1 ]C -r / J:]: o..~]. El'.~) 4 ~..~.._,~:,d '-:;QIJFIRE F'"EET hlFI;:.:;IMI..JM NUMBER I]F E:E[iF.I]L]M_~, :=: 2: SOIL RFITING ,"-") -" .',,' =,b. F T, BF.... = ':':': "rilE REQUI F.tED l~ ~ :,I..'.E [.IF TFIE SOIL -,c-,, - HD.:, _ F..F T I LIN '~' '¢" ' ::,'r :, TEH IS: TNE I_ENG'TH DIMENSION IS THE LENGTH ,::IN FEET) OF THE TRENCH OR r:iRRINF'IELE:,. THE DEPTH OF R TRENCH OR F'ZT IS THE DISTRNCE BETHEEN THE SURFFICE OF THE GROUND RND THE BOTTOM OF THE E',dCR'v'RTZON (IN FEET). THERE IS NO SET HIDTH FOR TRENC:HES. THE: GRRVEL DEPTH IS THE f'IINII'flUM DEPTH OF GRRVEL. BETHEEN THE OUTFRL. L PIPE FIND THE BOTTOM OF THE ENCRVRTION (IN FEET). FEF.I'I~T ~ff:FE.T....HNI H~S THE RE_,FLN_,IL:,.[LITT T'O ~NFORrd THIS r:,EPFIF~'.Ti'dENT [,LIF.'ZNG THE '"I"JSTFILLI:~TION ~t'~SFEUTIOi'4~: OF FI~'-t~T' I. IELL~, FIDJ'FICENT TO THZS FF..OFERTT FIN[.:, THE NI_IME=ER OF RE~:-.,IDENCES THFIT THE HELL HILL SER',/E, BFICKFZLLZNG OF RN'¢ :"'"-' ", -,r=,TEM 1.4.~THOUT FZNR/. [NSPECTTON RND RF'F'F.'Z'v'RL E?¢ TFIIS DEF'RR. THENT HILL BE _,UE.rE L ~ TO PF.'.ZSEC:LIT ~ON. HINIMUM DISTRNCE IbETHFEN R HELL. RND RNa' ON-SITIE. SEHRGE DISPOSFtI_ S¥S"I"EM IS ±E1EH FEET FOR Ft PRf'¢FITE HELL OR ±SEl TO 2EHEt FEET FROM FI PUE',LIC HF_'LL DEF'EI'.,IDING LIPON THE T'¢F'E OF PUBLIC HELL. hlINII'dUM DISTFINCE FROM Fi PRIVFITE HELL TO R PR.I',,,'FITE SEHER LINE :IS 25 FEET RND TO FI COI','IHUI',ItT'¢ SEI4ER LTNE ]:S 75 FEET. HIELL LOGS FIRE REQUIRED RND MUST E:F RETURNED TO THEE [:,EPFiRTMENT HITHIN S.~E~ DFI'.:.'S OF TNE HELL COHPLETTON. OTHEF.'. RE(.]UIREMENTS MFI'¢ RPPL'¢. SPECIFZCRTIONS FIND CONSTRUCTION DZFiGRRMS FIRE FI',/RILF~BLE:. TO INSUF.'.E PROPER INSTFiLLR"f'ION. I C:ER'rlF'¢ TF.IFIT ±: I FIM FFIMILIF~R. HZTH THE F.:EQUIREMENTS FOR ON-SITE SEHERS FiNE:, HELLS RS SE']" FORTH B'¢ THE MUNIC:ZPFILZT'¢ OF' FtNCHOF.':RGE. 2: I HILL. INSTRLL THE: SYSTEM IN RCCORr.~FINCE HZTH THE CODES. 3: Z UNDERSTFIND TFIRT THE ON.-SITE SEHER $'¢STEM MR'¢ REQUIRE ENLRRGEMEN]" IF' THE RESIDENCE I~hl~E:,ELEE:, TO ZNCL_UDE MOF.E THFiN 2: BEDF.:_-3MS. 4040 "B." STREET, ANCHORAGE, ALASKA 99503 PHONE: 907.279-2581 April 6, 1976 Mr. Earl Korynta Unwin Scheben & Korynta 103 East 26th Avenue Anchorage, AK 99503 Re: Subsurface Investigation for Dryer Subdivision Located within SE 1/4, Sec. 27, T.12N., R3W., S.M., AK Dear Mr. Korynta: Ab instructed, we conducted a subsurface investigation for the above referenced property on March 26, 29 and April 1, '1976. The results of that investigation are included in this report. Following the text are: Vicinity Map Test Hole Location Sketch Idealized Soil Profiles Test Hole Logs Grain Size Distribution Curves Standard Explanatory Information Figure 1 Figure 2 Figure 3-6 Table 1' Sheets Sheets 7--9 Drilling was Accomplished utilizing a Mobile Drill B-50 drill rig mounted on a Flextrac-Nodwell tracked vehicle owned and operated by Denali Drilling, Inc. The test holes were logged, the drilling supervised and the percolation tests run by Mr. O.M. Hatch, staff geologist with Alaska Testlab. Samples were taken off the flights of the solid 'flight auger as it was brought to the surface. The samples were sealed in plastic bags and transported to the laboratory where their natural moisture content and dry strength was determined. Each sample was then visually c].assi, fied and grouped accord- ing to the soil's c. olor, texture, and grain size distribution. Labo].~atorv analysis was then done on the group as a whole rather than on individual samples. 'Unwin Scheben & Korynta April 5, 1976 Page 2 Nine groups were identified: Group A is a silty gravell_~ sand that is moderately frost susceptible~ being rated F-2. Its unified classi- fication is SM and its gradation is shown en Sheet 1. Gro_~B is a silty sandy, gravel that is moderately frost -- susceptible being rated F-1. Its unified classifica- tion is GM and its gradation is on sheet 2. Group C is a gravellz sandy silt that is highly frost ' susceptible being rated F-4. Its unified classification is SM and its g~ada~ion is shown on sheet 3. Group D is a very silty sandy gravel that is moderately · ' frost susceptible being rated F-1. Its unified classification is GM. Group E is a silty ~ravell~ sand that is moderately frost susce~%e-~-~lg ~a{~-~-2. Its unified classi- fication is SM and its gradation is shown on sheet 4. Group F is a slightly sandy silt that is highly frost - ' susceptible bei~g ra~ed F-4. ' Its unified classifi- cation is ML and its gradation is shown on sheet 5. Group G is a sandy silt that is moderately frost susceptible ' '- being--~at~d'~-2~. Its unified classification is SM and its gradation is shown on sheet 6. Gr___oup H is a silty gravelly sand that is moderately frost susceptible~in~--~ated F-2. Its unified classifi- cation is SM. Group I is a sand that is non-to-moderately frost susceptible - '--- being-rated NFS/F-2. Unified classification is SP/SM. Due to the difficulty of running percolation tests on the site at this time, a percolation test was run in test holes 1 and 5 only, though all holes were cased with 3/4" slotted PVC pipe. Unwin Scheben & Korynta April 5, 1976 Page 3 For the percolation tests, the test hlles were filled with wa{er and left overnight to saturate. On returning, the holes were refilled and the drop in the water level carefully monitored over the next 60 minutes. This procedure is not a standardized percolation test, however, we understand that the Anchorage Department of Environmental Quality prefers test performed in this manner %o evaluate a site for a proposed on-site sewerage.system. Using the above test, the observed minimum percolation rate was 5.5 min/inch for test hole 1, and 1.7 min./inch for test hole 5. Additionally, we estimate that the percolation rates for the other holes (using visual a~d laboratory data) to be: Test Hole 2 - Test Hole 3 - 'Test Hole 4 - Test Hole 6 - Test Hole 7 - Test Hole 8 - Less than 8 min./inch Less than 30 min./inch Less than 30 min./inch Less than 10 min./inch Less than 5. min./inch Less than 5 min./inch Depending on the results of the final percolation tests to be performed after access is provided ~ t]~e site, ~[i~c~h~e treatment plants~ may be required in the area of test holes 3 and 4. Even this area should percolate ~airly well -- particularly below ten feet. No water table was encountered during 'exploration. It. should .be noted, however, that the water level will fluctuate with seasonal and climatic changes. To help visualize the soil strata at the site, we have drawn some idealized soil profiles for the site. It should be remembered when using these though, that wide variances may, and probably do, exist between test holes. We hope this is sufficie~lt for your present needs, if we can offere clarification please do not hesitate to contact . Very truly yours, Melvin R~ Nichols, CE .' t fi/ It. J Test Hole #8 Depth in Feet From To 0 1.0 1.0 2~5 2.5 9.0 ~9.0 11.0 11.0 15.0 Table A WO #17646 Soil Description Peat, Pt, brown, damp F-2, Sandy, Silt, S.~M, brown, damp, stiff, damp, medium density, subro'unded par- ticles to 3". NFS, Sand, .S~j~/ brown, damp, medium, density. . F-2, Sandy, Silt, SM, brown, damp, stiff ~ Bottom of Test Hole: Frost Line: Free Water Level: ].5.0' 3.0' None observed Depth 1 2.5 2 5.0 3 10.0 '4 15.0 Type of Dry Blows/6" M% ~m lp_~' ].4.2 GRAB 21.9 G'R.A B. 7.5 C~RAB 9 '; 7 GPAB Strength Grou~ Unified N G SM N B GM N I S P / S H N G SM ~4 MUNICIPALITY OF ANCHORAGE I Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 017-342-05-000 Expiration Date: Legal description LA FORET LT 5 Site address 13351 GINPOLE CIR Anchorage AK 99516 Current property owner(s) CHASE JAMES H & YVONNE M 9/13/2025 X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: By: Original Certificate Date: 11/19/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 017-342-05 Complete legal description La Foret, Lot 5 Location (site address) 13351 Ginpole Cir, Anchorage, AK, 99516 Current property owner(s) James & Yvonne Chase Day phone 2. ON-SITE SYSTEMS SIZED FOR 3 BEDROOMS 3. TYPE OF WATER SUPPLY: ❑■ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ■❑ Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑■ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 28 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ■❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Distance: Expedited review requested: ❑ By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ _152GO Waiver Fee $ Date of Payment 1 V Z I 'Z - Date of Payment COSA # -c)G 2 9 1'-126 Waiver # COSA Application—June 2022 10/7/24 (A+) N/A Benjamin Schiller, P.E. (907) 522-7773 GINPOLE CIRCLE .,R WELL inn' Lot .., HOUSE DETAIL Scale: 1" = 30' NOTE: GROUND LEVEL IMPROVEMENTS SHOWN ARE APPROXIMATE DUE TO SNOW COVER. Lot 3 Tract A 71 S 00'04'05"W 56.24' Lot 2 PLOT PLAN AS BUILT _X SCALE 1" = 50' GRID SW 2937 Project No. J24 -288,1A1 P.O. Box 210005 Lang & Associates, inc. Anchorage, Alaska 99521-0005 0000pOOZP24- Professional Land Surveyors Jonet 522-6hanOlan976surveycom �/ v a OF A411"N at� • • • kenOlangsurvey.com'9s Q I hereby certify that I have surveyed the following described property: LOT 5, LA FORET SUBDIVISION (Plat No. 77-1) Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on said �p,,roopperty except as Indicated hereon. Dated this the " ' `I Day of _ �6J EM �`at Anchorage, Alaska It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. �* H JONAT C. LANG a G LS-9944..- State S-9944.• State of Alaska AECC963 MUNICIPALITY 0f ANCHORAGE - DEPARTMENT OF HEALTH & HUMAN SERVICES. Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage,'Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. HAA# ~~°t L~ ~E3 \OA,~ GENERAL INFORMATION Complete legal description Location (site address or directions) Property owner FA,I,D ~ Lending agency. Mailing address Day phone ,3 ¥5-- 'fi' 2_5-¢ Day phone Agent_f/,o(~/' h~.~c~... R~** Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 3o TYPE OF WATER SUPPLY: Individual well ,: Community well ~ Public water Day phone ~ ~? _0/.%5- · NOTE: If community well system, provide written confirmation from State ADEC attest- lng to the legality and status of system. TYPE OF WASTFWATER DISPOSAL: individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA #21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by ,m:y seal a~fixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type ofstructure indicated herein. I further verify that based on the information obtained from the Municipality of. Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance .with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Address Engineer's signature 6. DHHS SIGNATURE /~' Approved for -,~ Disapproved. Conditional approval for Phone 2' ¥5-° /-? 5'5- bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DH HS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025(Rev. 1/91) Back MOA~21 Legal Description: A. WELL DATA Well type Log present (Y/iq) Total depth _ ~ t 19 Sanitary seal (Y/N) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVlCE E C ElY E D Environmental Services Division 825"L" Street, Room 502 ® Anchorage, Alaska 99501® (907) 343-~FA4~ ~ 0 1996 Municipality of Anchorage DePt, Health & Human services Health Authority Approval Checklist Lr~'P ~ 2-~ Fo r e [' ..C/d) ParcelI.D.: If A, B, or C, attach ADEC letter. ADEC water system number Date completed Cased to _ ~ g't9 Casing height (above ground) 'f' Wires properly protected (Y/lq) Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform Date of sample: __ t./ / Z3 / 9 ,'f' B. SEPTIC/HOLDING TANK DATA FROM WELL LOG AT INSPECTION __ Il IE/g~9 _ 5/ / g3/96' 19 2 ' EOI or' g.p.m. 3, q g.p.m. Nitrate z. c,. I~,f /..~ Otherbactefia ~ col Collected by: ~/',~,F,~ 7'e c/, Dateinstalled ~'t /Io/ lc/o/ Tanksize i~Opff__~NumberofCompartments E Depression (Y/N) t4 Pumper ~ Soil rating (g.p.d./ft~ or fta/bdrm) O~ ~9 _ Foundation clem~out (Y/N), Date of Pumping N. C. ABSORPTION FIELD DATA Dateinstalled q / l~' /~2 f High water alarm (y/N) Length ~3' ~'ff ~' ~ 2 Width E.J," Gravel thickness below pipe Effective absorption area ~.~ ~ Ct' Monitoring Tube present(YAq) Date of adequacy test rd. A. Results (Pass/Fail) Poz.r _ Fluid depth in absorption fteld before test (in.); Fluid depth (ins.) Minutes later: Peroxide treatment (past 12 months) (Y/N) .___ Cleanouts (Y/iq). Y Immediately after Absorption rate = If yes, give date __ System type '"Fron 7, g' . Total depth I~, Depression over field (Y/N) For 2 bedrooms __ gal. water added (in.): g.p.d. D. LIFT STATION ~J. /}. Date installed Manhole/Access (Y/N) High water alarm level at* Cycles tested Size in gallons "Pump on" level at* E. SEPARATION DISTANCES *Datum SEPARATION DISTANCES FROM WELL ON LOT TO: ; On adjacent lots .'> ! oo~ Septic/holding tank on lot [ '8 ~ ' ; On adjacent lots 13t( ' Absorption field on lot ~> l ~ ~ "Pump off' level at* Public sewer main ~. At, Public sewer manhole/cleanout ~. ,4. Sewer/septic service line ~> ~3" Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation fj ~ Property line 75' t Absorption field '> ! o ' Water main/service line '~ E3~ Surface water/drainage > too, Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation Property Line E'O ' .Water main/service line Surface water Driveway, parking/vehicle storage area '~ '2,~' ' Curtain drain Yo o e ~' e~oo Wells on adjacent lots Signature ..~~ Engineer's Name Date ENGINEER'S CERTIFICATION I certify that I have determined thrufield inspections and review of Municipal recot~d$ ~hat: th~'ab~¢~ :~ste3k. are in conformance with MOA HAA guidelines in effect on this date. ~; ,, ', '.'. ', Ci~-? , ,,' :.: . HAA Fee $ 3 06:' ~ Receipt Number //f~ (~-~/V~)x~ Rev. 8/95 OSS: haa.wk.doc Waiver Fee $ Date of Payment Receipt Number CT&E Environmental Services Inc. Laboratory Division Laboratory Analysis Report CT&E Ref.# Client Sample ID Matrix PWSID 0 961432.11777 L5, LA FORET S/D11432-01 Drinking Water Collected Date 04/23/96 Technical Director: Stephen C. Ede Released B y__..~.~.~ Sample Remarks: Nitrate-N Results QC qual 0.100 u PQL Units 0,100 mg/L Hethod Allowable Prep Analysis Init Limits Date Date EPA 353.2 04/24/96 EMi' U - Undetected LT - Less than GT - Greater than O - Secondary Dilution J - Below the calibration rang~ 200 W. Potter Drive, Anchorage, AK 99518-1605 --Tel: (907) 562-2343 Fax: (907) 561-5301 3180 Peger Road, Fairbanks, AK 99709-5471 -- Tel: (907) 474-8656 Fax: (907) 474-9685 ENVIRONMENTAL FACILITIES IN ALASKA, CALIFORNIA, FLORIDA, ILLINOIS, MARYLAND, MICHIGAN, MISSOURI, NEW JERSEY, OHIO, WEST VIRGINIA ~ D.,~;F E RECEIVED : ' INSPECTION APPOINTMENTS ~,~Z~x-~.,~.L~.~ T~M~ TIME TIME ~AT~ DATE DATE ~SPECTOR I NSP ECTOR I NSPEC~ MUNICIPALI~ OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPT. OF  DEPARTMENT OF HBALTH & ENVIRONMENTAL PROTEOTI~IRONMENTAL . ,L TECTION 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL SANITATION DIVISION NOV ~ ~ ~80 Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEW DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed, Please allow ten (10) days for processing. ~ PROPERTY OWNER ~ PHONE MAILING ADDRESS PFIOPERT~ RESIDENT (If different from above) PHONE ~ BUY~--~ PHONE MAILING ADDRE88 ~AILING ADDRESS ~ REALTOR/AGENT PHONE ~AILING ADDRESS LEGAL DESCRIPTION STREET LOCATION 6. TYPE OF RESIDENCE NUMBER OF~BEDROOMS [] One [] Four ~ SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY I)~ Three [] Six [] Other 7, WATER SUPPLY INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LQG. A well Icg is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach Icg if available.) 8, SEWAGE DISPOSAL SYSTEM /~ INDIVIDUAL/ON-sITE** [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED, NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6/7g) THIS SIDE FOR OFFICIAL USE ONLY 1, TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED__1~-~' 3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVI DUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER []Septic Tank or [~] Holding Tank Size: ]~(~) If Tank is homemade I SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4, DISTANCES Septic/Holding Tank IAbsorption Area Sewer Line I Nearest Lot Line I WELL TO: Absorption Area to nearest Lot Line 5, COMMENTS I~]"/~APP OVED FOR . ~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED DATE BY 72-010 (Rev. 6/79)