On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: OSP 111243 PID Number: 015-134-25
Name:
ELIZABETH GOODRICH WastewaterSystem: [] New · Upgrade
Address:
10541 ELIES DR *ANCHORAGE, AK 99507 ABSORPTION FIELD
Phone: No. of Bedrooms:
(907) 546-1435 3 [] Deep Trench [] Shallow Trench · Bed []Mound BOther
LEGAL DESCRIPTION so,, Rotlng: Total Depth, ..... icJinol grade:
0.8 GPD/Sq. Ft. 12 MAX
Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe:
1 7 LAKEWOOD HILLS #4 4 MAX rt. 8.0 rt
Township: _ Range: _ Section: NIl added above original grade: Gravel length:
SEE DWG. Ft. 2 @ 20 = 40
WELL: [] New [] Upgrade Gravel width: 2.5 Ft. Number of 2 Ii .... Dist .... lb~ .... Ii .... Ft
Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material:
PRIVATE 114 Pt. 114 rt. 640 sQ. rt.D 3034/ F-810/HDPE
Driller: Date Drilled: Stotlc Water Level: Installer: Date installed:
ALPINE DRILLING 10/5/11 84 Ft. A+ HOME SERVICES 9/15-15/11
Yield: Pump Set At: Casing Height Above Ground:
10 GP. 1 03 Ft. 2+ rt. TANK
SEPARATION DISTANCES [] Septic [-I Holding E] S.T.F.P. [] Other*
T~rom~'~"~° Septic Absorption Lift Holding Public/Privat( Manufacturer;. Capacity in gallons:
Tank Field Station Tank Sewer Lines ANCHORAGE TANK 1250
Material: Number of compartments:
WaR 100'+ lO0'+ - - 25'+ STEEL 2
Surface Wo~er ~00'+ ~00'+ -- -- -- LIFT STATION
Lot Line ,5'+ 10'+ _ _ _ Size in gallons:IJ Manufacturer:
"Pump on" level at:
"Purr alarm at:
Foundation 5'+ 10'+ - -- --
Curtain Drain ' NONE KNOWN ~ Pump No__cai Inspections performed by:
I I
Remarks: OLD TANK WAS DECOMMISSIONED PER UPC. BENCH MARK
Location and Description:
OLD TRENCH WAS ABANDONED IN PLACE. BOTTOM OF TRIM ON SE CORNER OF HOUSE
OLD WELL WAS DECOMMISSIONED PER UPC.
A~ .... d Elevation: 97.93 Ft.
ENGINEER'S SEAL
Inspections performed by: CEC, Ltd. Dates: 1st 9/13/11
2nd 9/14/11 ~',<, %,, ......... ~-1
3rd 9 / 14/11 ¢¥~.~%.. · ' ' ' ' ~'"'.
Development Services Department Approval ~.~i.i...4..9,
Conditional approval: Date' ¢,:: :: :. ......... ':: ..... ...........
~ ¢ '-.Jeffrey -A. _Garness.:
v~k~. ".. CE-7955 .."
PERMIT NUMBER:
OSP1 1 124.3
/
/
/
/
?
/ /
/
/
/
/
/
/ SHED
/
/
/
I
AS-BUILT DRAWING
[ A ~ C
ST1 87.11 64.5.3 78.26
ST2 95.40 72.91 86.75
DBL1 58.05 44.80 29.06
DBL2 58.19 44.79 29.08
DBL5 96.79 74.95 88.91
DBL4 96.48 74.90 88.96
C01 87.82 68.82 85.59
MT1 78.75 59.55 74.22
C02 68.06 48.90 64.05
MT2 70.27 60.05 75.79
C03 51.46 43.86 59.54
C04 70.89 60.56 76.14
MH 59.24 44.60 28.97
PARCEL ID NUMBER:
015--1.34--25
/
/
/
/
/
/
/
/
/
/
/
/
/
I
I
100' WELL RADIUS
24" DIAMETER ORENCO PUMP VAULT WITH 2"
SOLIDS TRANSFER PUMP & ORENCO CONTROL
PANEL.
/ 2" HDPE
(NO JOINTS
I PROFESSIONALLY J-/
IL°cATED/
EXISTING 3
BEDROOM
DRAINFIELDS
LONG EACH)
SCALE:
\ I I
\ 1" = 40'
NEW 1250 GALLON/
SEPTIC TANK ~
/
/
G-A:R'N'ESS ENGI'N'EERING GROUP, Ltd
: C:ON8 U LTANTS & GE N E~AL G ONT~GTO ~
* ~: www.gamessengineefing.~m
PREPARED FOR: PHONE NUMBER: PAGE NUMBER'
,AX~WOOD ,~,,s ~ ,LOCX ~. ,OT 7 I
w
~s-,u~LT ~<w~,~ I ~o/~/1~
PERMIT NUMBER: AS--BUILT DRAWING PARCEL ID NUMBER:
0SP111243 015-134-25
f FINAL GRADE = 104.81-104.93
ST1 / ST2
TOP OF TANK t( ~:1 /-- TOP OF TANK
AT INLET = 100. ~ ~A1AT OUTLET = 100.72
I/
NEW 1250 GALLON
INVERT OF BUNG SEPTIC TANK I I X-INVERT OF BUNG
AT INLET = 100.22 l/ AT OUTLET = 99.95
FINAL GRADE -~.
= 100.25+
NORTH SOUTH
GRADE
FINAL
= 101.25+
GRADE
100.62
FABRIC
FABRIC
OF PIPE
= 96.62
OF PIPE
95.76
16'+
BoTroM OF
TRENCH =
88.62
BOTTOM OF'
TRENCH =
87.76
RELATIVE ELEVATION OF BOTTOM OF TESTHOLE @ HIGHEST POINT= 82.62 (DRY)
RELATIVE ELEVATION OF BOTFOM OF TESTHOLE @ HIGHEST POINT= 81.76 (DRY)
GARNESS . G IN EER. I. NG G iR.O'U P, Ltd~
CONStJLTA~NTS & GENERAL CONTRACTORS
PREPARED FOR: I PHONE NUMBER:
ELIZABETH GOODRICH I 346-1433
LEGAL DESCRIPTION:
LAKEWOOD HILLS #4; BLOCK 1, LOT 7
PAGE NUMBER:
3OF3
DRAWN BY:
DATE: PNB
9/21/11
TYPE OF WORK:
PROFILE AS-BUILT DRAWING
(Rev 0'~/05)
FROM :Alpine D~illin@ FA× NO. :907 345 0202 Oct, ll 2011 11:46PM P2
Alpine Drilling & Enterprises
Well Log
B°rehole Data:
Soil Type, Thickness & Water Strata
Sack-up 0 2
set 2 7
gravelly silt 7 13
silt 13 19
gravelly sandy silt 19 31
Mlty gravel 31 36
silt 36 54
gravelly silt 54 63
silty gravel 63 81
gravel 81 94
silty gravel 94 102
silt 102 106
silty water sand & gravel 106 114
Permit Number:. #SWOSP111273 Date oflssue: ~10-3-11 Parcel Identification Number: 015~13425000
Date Started: 10-3-11 Date Completed: 70-3-11 Is well located at approved permit location? x Yes [] No
Legal Description: Lakewood Hills # 4 Block 1 Lot 7
Property Owner Name & Address: Elizabeth M. Goodrich
10541 Eries Drive
Anchorage, Alaska 99507
Depth (ft) Method of Drilling x air rotary [] cable tool
From To
Casing type: steel
Wall Thickness: .250 inches
Diameter: 6 inches Dep/h: 114 feet
Liner Type: ~
Diameten ~ inches Depth: ~ feet
Casing..stickup above ground: 2 feet
Static water level (from ground level): 84 feet
Pumping level: 114 feet after
2_ hours pumping 10 gpm
Recovery Rate:/_0 gpm
Method of Testing: ~
Well Intake Opening Type:
x Open End [] Open Hole
[] Screened Start~ feet Stopped ~
[] Perforations Start __ feet Stopped~
Grout Type: ~bentonite
Depth: Start.O feet
Pump: Intake Depth __ feet
Pump size ~ hp Brand Name __
Well Disinfected Upon Completion? x Yes [] No
Method of Disinfection: chlorine tablets
Comments:
Well Driller: Alpine Drilling & Enterprises
PO Box 110496
Anchorage AK 99511
feet
· feet
Volume: ] bg
Stopped ? feet
F~× ~0, :907 3~5 8282
Development Services Department
Building Sefefy Division
On-Site Water & Wastewatev Program
4700 EImore Road
P.O. Box 196650
Anchorage, AK 99507
~w.muni.or~/o~ite
(90~ 343-7904
Pump Installation Log
Well Drilliug Pemit Number: SW([~/~[//~ ~_~
Parcel ldentitication Number:O/5/' .~'~~
Pump Intake Depth Below Top of Well Casing:./_~ feet'
Properly Osmer Name & Address:
Pump Manufacturer's Name:
Pump Model:
Pump Size//~ hp
Pitless Adapter Burial Depth: /_~ feet
Pitlem Adapter Mannfacturer's Name: /~'/.,4r_~
~tJe~ Adapter I~taller:~'~.~
Well Disinfected Upon Completion?C~¥es [] No
Method of Disinfeetion:
Comments:
Pump Installer Name:
Attention: ) installation log to thc DSD within 30 days of pump installation.
Page 1 of 1
Sonja Blewett
From: David Harper [dlharper2@gmail,com]
Sent: Tuesday, October 11,2011 11:56 PM
To: Sonja Blewett
Subject: Re: Well Log & Pump Log
Sonja, the original well located on Block 1, Lot 7 Lakewood Hills # 4, has been decommissioned
as per DEC and MOA requirements. The existing well could not be deepened because of
perforations. Depth of the old well was 100 feet. New well depth is 114 feet.
David L. Harper
Alpine Drilling & Enterprises
On Mon, Oct 10, 2011 at 12:34 PM, Sonja Blewett <Son~arnessen~.com> wrote:
Do you have the well log and pump log for 10541 Elies Drive. Thanks!
Sonja Blewett
Corporate Secretary/Treasurer
Garness Engineering Group, Ltd.
3701 E. Tudor Road, Suite 101
Anchorage, AK 99507
Phone: .(907)_ }_37-6179
Fax: 907~8-3246
10/12/2011
APPLICATION NO.
17:05 86@6770
~PLU$ PAGE
Municipality of Anchorage
Community Development Department - Development Services Division
P.O, 60× 196650 - Anchorage, Alaska 99519-6650 - 4700 EImore Road
info and Help: (907} 343-8211
INSPECTION: Voice: (907) 343-8300 Fax (907~ 249-7777
Inspection Report- Electrical
Permit Type: Electrical
RETROEI.11440
Res
Schedule ~~
~~:' ' Preference:AM;'*;
Ad~resSof rolec: 0 ~ ' '
Lega:* LA iLL '1 ' : 4 ' ' ' '
~$cripti°n"°fW°~ki
~' (907)346.143~ GOODRICH ELIZABETH M
ED~S, EbEO,-FR,iC~,iNC P.O. BOX 210767 . ,,, .
Cont~a~or (907)272~591
I~ctor Commenm:
' RETRO
R-E
PERMIT NO.
86@6770 APLUS PAGE 01
Municipality of Anchorage
Community Development Department
Development Services Division
P.o. E~ox 196650 - Anchorage, Alaska 99519.6650 - 4700 Elmore Road
Phone: (907) 343-8211 Fax (907) 343-8214 http://www, muni.org
THIS PERMIT MUST BE POSTED IN A CONSPICUOUS PLACE AT THE
ADDRESS OF WORK UNTIL WORK IS COMPLETED AND APPROVED
RETROE111440
1 LT 7 G:2540
Address of P~oject:
10541 EL/ES DR, Anchorage
Legal:
LAKEWOOD HILLS ~4 BLK
Description of Work:
RESIDENTIAL ELECTRICAL RETROFIT PERMIT
Issue Date:
PM: pwwab
Expiration Date:
Parceh
01513425000
Subdivision:
LAKEWOOD HILLS ~
09/19/2011
09/13/2012
Install electrical for a septic rift system / tb
Permittee:
ED'S ELECTRIC INC
Permit Type:
Electrical
Owner:.
GOODRICH ELIZAEIETH M
Address:
P.O. BOX 210767 ORUNS, DWAYNE R., ANCHORAGE AK
Existing Use: P~'~sed Use:
R-3
Address:
10541 ELIES DR ANCHORAGE, AK 995076234
All Work in strict conformance with plan check requirements as per job prints. Field inspection required.
Inspection required of foundation excavation prior to placing any classified fill.
Contact the utility for approval of service equipment and location pr/or to installation. Service changes must be scheduled in aclvance
with the utility cOmpany and the Building Safety inspection sect/on.
I HAVE READ THE ABOVE APPLICATION AND KNOW THE CONTENTS THEREOF: THE SAME IS TRUE AND
CQRRECT. I FURTHER AGREE THE ABOVE WORK WILL BE DONE IN ACCORDANCE WITH ALL STATE AND
MUNICIPAL LAWS AND ORDINANCES.
PERMIT EXPIRES IN 360 DAYS IF WORK IS NOT COMMENCED AND NO
INSPECTIONS PERFORMED.
3ignature of Permi~tee or Agent:
>rinted Name:
Permit Number:
Tax Code Number:
Work Type:
On-Site Water System Permit
OSPl11273
01513425000
Well
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 EImore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Upgrade
Permit Effective Dates: October 03, 2011 to October 02, 2012
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: LAKEWOOD HILLS #4
Site Legal Address: LAKEWOOD HILLS #4 BLK 1 LT 7 G:2540
Owner/Address: GOODRICH ELIZABETH M
10541 ELIES DR ANCHORAGE AK 995076234
Site Mailing Address: 10541 ELIES DR, Anchorage
Lot Size in Sq Ft: 46609
Total Bedrooms: 3
This permit is for the construction of:
N Disposal Field N SepticTank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343~7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: The existing well is to be decommissioned prior to inspection report approval.
Received By: "' '"¢~'~'~' ¢''~'' b :" f~'~ ~'? ,"' / /
Date: ,- ..
Issued By: ~~ Date:
/
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services
On-Site Water & Wastewater Program
~ Phone:907-343-7904
Fax:907-343-7997
Mayor Dan Sullivan
On-Site Sewer/Well Permit Application
For A Single Family Dwelling
Parcel I.D. 015-1,54-25
Property owner(s) ELIZABETH GOODRICH
Mailing address 10541 ELIES DRIVE *ANCHORAGE, AK 99507
Day phone 546-14,53
Site address 10541 ELIES DRIVE *ANCHORAGE, AK 99507
Legal description (Sub'd, Block& Lot) LAKEWOOD HILLS #4; BLOCK 1, LOT 7
Legal description (Township, Section & Range)
Lot Size Sq. Ft. Number of Bedrooms 3
THIS APPLICATION IS FOR:
( [] all that apply)
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
N/A
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees: .~:i~-¢-, :.~¢,~--~.~ ¢_0¢q'~'~ ',~-Waiver Fees:
!
Date of Payment: '~'~..;~ ~i ", ~i Date of Payment:
Receipt Number: ~i.5 "~,~; ~
~ ,, Receipt Number:
Permit No. ~ '-~ ~ ~ '~- ~ .O Waiver No.
(Rev. 01/11)
:GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONT~CTORS
September 29, 2011
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: Proposed Well Upgrade for Lakewood Hills #4; Block 1, Lot 7,
To whom it may concern:
The existing 3 bedroom house is served by a private well and septic system. The existing well was
recently inspected by Dave Harper at Alpine Drilling and was discovered that the well is not producing
adequate water production. We are proposing to have the existing well decommissioned per UPC and
have a new well drilled near the same location as the existing well.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems.
If you have any ~stions, please contact us at 337-6179. Thank you for your assistance.
/ \
~Sincerely, ~
_~ar'rr~s, P.E., M.S.Presj~te~
NOTE: Attached is a site plan drawing and design drawing.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907)337-6179 * Fax: (907)338-3246 * Website: www.gamessengineering.com
I I
I ' WELL DRILLER IS RESPONSIBLE FOR
I I I VERIFYING SEPARATION DISTANCES FROM
~1 HAMPTON HILLS; THE PROPOSED WELL LOCATION TO ALL
I I BLOCK 2, LOT 2 I SURROUNDING SEPTIC SYSTEMS.
I _1 la,. LAKEWOOD HILLS #4;
~ I~lJ BLOCK 1, LOT 9
' I I I 1
//! BLOCK 1, LOT 8 ;
//! HAMPTON HILLS; ,
/ / I BLOCK 2, LOT 5 ~~ I
,,'// /I/ ,,' ,,
// ///
FIELD VERIFY II BLOCK 7. iLOt ~
, k ~ i ~//
/ ;,,, -.- ~ iiii
/
/ I PROSPECTS HEI~TS ~2;
I SCALE:
z ~ I I
1" = 100'
I
~7~E~D~R~SU~*~cH~E~99~7*PH~NE(~7)~7-6~79~F~(9~7)~-~2~6*W~S~gPREPARED FOR: PHONE NUMBER- , PA~E ..... NUMBER:gineefing .... ~'~ ~/~ ...... ~.. .........
ELIZABETH GOODRICH I 346-14~3 I 1 OF 2 ~'F~h~~e//ey~Ge ness.-'
LEGAL DESCRIPTION: D~WN BY: ~ "~ rCE~n .-"
~p~ of wo~x: ~A~:~
SITE PlaN (WELL PERMIT) 9/29/11
WELL DRILLER IS
RESPONSIBLE FOR
VERIFYING SEPARATION
DISTANCES FROM THE
PROPOSED WELL LOCATION
TO [~L~ SU RROU N DING
SEPTIC SYSTEMS.
\
/ \
\
~ ....... _ 1-- .... /..~~~ ~'
I ---- .. Il ////-EXISTING WELL TO BE
X ~ P~PO~D ~LL
SCALE:
1" : 40'
G. ARN'ESS ENGIN'iEER]NG G, RO:UiP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
3701 E. I~JDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 * PHONE (907)557-6179 * FAX (907)558-5246 * WEBSITE: www.gamessengineering.com
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
ELIZABETH GOODRICH 346-1433 2 OF 2
LEGAL DESCRIPTION:
LAKEWOOD HILLS #4; BLOCK 1, LOT 7
IDRAWN BY:
PNB
DAT~;9/29/11
~'PE OF WORK:
WELL DESIGN
]rness..
Permit Number:
Tax Code Number:
Work Type:
On-Site Wastewater Disposal System Permit
OSPl11243
01513425O00
Septic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Upgrade
Permit Effective Dates: September 12, 2011 to September 11, 2012
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: LAKEWOOD HILLS #4
Site Legal Address: LAKEWOOD HILLS ~, BLK 1 LT 7 G:2540
Owner/Address: GOODRICH ELIZABETH M
10541 ELIES DR ANCHORAGE AK 995076234
Site Mailing Address: 10541 ELIES DR, Anchorage
Lot Size in Sq Ft: 46609
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Date: c')//// g~////
Date: (~~--//~/
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services
On-Site Water & W~tewater Program
fldSH!
Parcel I.D. 015-134-25
Mayor Dan Sullivan
On-Site Sewer/Well Permit Application
For A Single Family Dwelling
Property owner(s) ELIZABETH GOODRICH
Mailing address 10541 ELIES DRIVE *ANCHORAGE, AK 99507
Phone: 907-343-7904
Fax: 907- 343-7997
Day phone 346-1433
Site address 10541 ELIES DRIVE *ANCHORAGE, AK 99507
Legal description (Sub'd, Block & Lot) LAKEWOOD HILLS #4; BLOCK 1, LOT 7
Legal description (Township, Section & Range)
Lot Size Sq. Ft. Number of Bedrooms 3
THIS APPLICATION IS FOR:
( [~all that apply)
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
N/A
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
~o~q 17
ush Fees:
Date of Payment:
Receipt Number:
Permit No. O'~¢
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
(Rev. 01/11)
GARNESS ENGINEERING :GROUP., Ltd.
CONSULTANTS & GENERAL CONTRACTORS
September 6, 2011
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: Proposed Septic Upgrade for Lakewood Hills #4; Block 1, Lot 7,
To whom it may concern:
The existing 3 bedroom house is served by a private well and septic system. The septic system is in a state
of failure and needs to be upgraded. We are proposing to install a new 24 inch pump vault, a 1250 gallon
septic tank, and a dual deep trench type drainfield. One test hole was excavated on the property. The
drainfield will be designed around the 30 foot radius of this test hole. Comments regarding the design are
summarized as follows:
1. SOILS: See the attached log which shows the soil classifications, groundwater monitoring, and the
percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfieid specifications.
3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system.
4. TOPOGRAPHY: As can be seen on the attached topo drawing the topography around the drainfield
runs south to north at approximately 20% slope. In short, there are no slope concerns.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems.
If you have any q~,'stions, please contact us at 337-6179. Thank you for your assistance.
P.E., M.S.
NOTE: Attached is a site plan drawing, a design drawing, one soil log, which are all part of the design package for
this septic system. (Contact G.E.G. Ltd..for 7 page construction specification letter.)
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
I I HAMPTON H LLS
I I BLOCK 2, LOT ~
I _1 ,5, LAKEWOOD HILLS #4-; I
I T"-~ I~ BLOCK 1, LOT 9
)/) ~ ~ ~KEWOOO H,LLS ~,
//! BLOCK 1, LOT 8 ;
I/I HAMPTON HILLS; I
/// BLOCK 2, LOT 3 / ~ ~ -- ~ ~ m
// II/ ,' , ,
HEIGHTS
~2;
m ~ BLOCK 7, :LOT 3
/ ~~ PROPOSED SEPTIC
SYSTEM
HAMPTON HILLS: / / / ', ~ "'X .~KEWOOD HILLS ~4[ I
/// ," .---~<-~r--" ~,
GA~N'.ESS
~.~-~ /~~ .... ':.~.:~
PREPARED FOR: m PHONE NUU.~.: I PAGENUMBER:
[1, z,,[~H OO0~,,CH m ~-,~ m , o[~ ~~~;~)~..-~
LEGAL DESCRIPTION: DRAWN BY: ~'~h~. I'/. ~E-795~ ..' ~/
LAKEWOOD HILLS ~4; BLOCK 1, LOT 7 PNB ~q~*~*~'/"
SITE PLAN 9/6/11
DESIGN CRiTERiIA: I
NUMBER OF BEDROOMS: 3
GALLONS PER DAY (GPD): 450
PERCOLATION RATE/S: 1.8 MIN/INCH
PROPOSED APPLICATION RATE: 0.8
MINIMUM DRAINFIELD SQ.FT.: 563 SQ. FT.
DRAINFIELD DESIGN:
MAXIMUM DEPTH: 12' MAX
WIDTH: 2.5'
LENGTH: 2 @ 20' = 40"
M.O.A. APPROVED SAND FILTER: N/A
EFFECTIVE: 8'
REDUCTION FACTOR: N/A
ACTUAL SQ.FT.: 640 SQ. FT.
/ /
GEG, Ltd. HAS A 7 PAGE SPECIFICATION
LETTER THAT PERTAINS TO THIS DESIGN.
TO OBTAIN A COPY OF THE LETTER
CONTACT GEG. BY PROCEEDING FORWARD
WITH THIS INSTALLATION, THE ENGINEER,
WELL DRILLER, CONTRACTOR AND
PROPERTY OWNER AGREE THAT THEY
HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT THE TERMS AND
CONDITIONS OUTLINED.
/
/
/
/
/
/
/
/ /
/
/
/
NOTE: THE CONTRACTOR
SHALL HAVE THE SOUTH LOT
LINE, AND ALL WELL RADII
FLAGGED BY A REGISTERED
LAND SURVEYOR PRIOR TO
CONSTRUCTION.
/
NOTE:
HAVE
PROFESSIONALLY
FLAGGED PRIOR
CONSTRUCTION.
I
I
· EXISTING SEPTIC TANK TO\BE "DECOMISSIONED"
PER UPC. DRAINFIELD TO ~3E ABANDONED IN
~LACE.
\
\
\ \
I
/ /
? /
// /
///2"HDPE W/ NO
MUST BE
PLACED IN
CONDUIT.
SCALE:
I
GARiN'ESS ENGIN'EERING GROUP, :Ltd.
~' :;';~;~:'~;~ CONSULTANTS & GENERAL CI
TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 * PHONE (907)~7-6179 * FAX (907),338-3246 * WEBSITE: www.gamessengineering.corn
THE CONTRACTOR SHALL
THE WATER LINE
LOCATED &
TO STARTING
PREPARED FOR: I PHONE NUMBER: I PaGE NUMBER:
ELIZABETH GOODRICH I 346-1453 I 2 OF 2
LEGAL DESCRIPTION: I DRAWN BY:
LAKEWOOD HILLS #4; BLOCK 1, LOT 7 I PNB
OF WORK: I91DATE:/6/1 1
SEPTIC DESIGN UPGRADE
24" DIAMETER ORENCO PUMP VAULT
WITH 2" SLUDGE TRANSFER PUMP & ORENCO
CONTROL PANEL. PROVIDE HIGH LEVEL ALARM IN
HOUSE. PUMP VAULT SHALL BE LOCATED GREATER
THAN 10 FEET FROM THE WATER SERVICE LINE.
EXISTING
BEDROOM
TH#I
/
1250 l~
GALLON SEPTIC
TANK /~
DRL
C/O'S & FLOW
SPLITTER.
PROPOSED
DRAINFIELDS
20' LONG EACH
GARNESS .ENGINEERING GROUP,
[SOIL LOG - PERCOLATION TEST[
ORGANICS TESTHOLE ffl [
MIXTURE
OF GM
& SM
MATERIAL.
SOIL CLASSIFICATIONS
GW ~ ORG
GP ifiL
OH GL
GC OL
SW IfiH
SP CH
Sift OH
SC
DEPTH TO
GROUNDWATER DATE
DRY 8/27/11
DRY 8/29/11
DRY 9/1/11
DRY 9/6/11
\
/
LAKEWOOD HILLS #4;
// BLOCK 1, LOT 6
/
\
DATE
READING
CLOCK
TIHE
NET TlifiE
(PIlNUTES)
WATER LEVEL
READING
NET DROP
(INCHES)
0.50"
9/1/11 1 11:35 - 6.00" -
2 11:4,3 10 0.00" 5.50"
3 11:44 - 6.00" -
4 11:54 10 0.50" 5.50"
5 11:54 - 6.00" -
6 12:04 10
5.50"
7 12:04 - 6.00" -
8 12:14 10 0.50" 5.50"
9 12:14 - 6.00" -
10 12:24 10 0.50" 5.50"
11 12:24 - 6.00" -
12 12:34 10 0.50" 5.50"
SOILS LOGGED BY:
COIfiHENTS'.:
PERFORMED BY GEG, Ltd. I, ,JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ~/~/ll
7=!
PERCOLATION RATE 1.81 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES
TEST RUN BETWEEN 5.5 FT. AND 6.5 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: [] YES [] NO
ROB CAMPBELL PERCOLATION TEST PERFO~HED BY: ROB CAMPBELL
IN ACCORDANCE
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION \ "~ ,-
ENVIRONMENTAL ENGINEERING DIVISION ~;
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ; i~"
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
PHONE ~./..~ [] NEW
NAME C~ ~ ¢~C'-~ ~ g $ ~ '~-~ ~ .-[~'19~GRADE
MAILING ADDRESS
LEGAL DESCRIPTION
LOCATION NO. OF B~DROOMS
Well Absorption area Dwelling PERM T NO.
DISTANOETO: 10~ ~' Materia I %
Manufacturer ~ No, of ~om~artme~ts
Width
DISTANCE TO:
Manufacturer
DISTANCE TO:
No. of lines
Length
Type of crib
DISTANCE TO:
Class
DISTANCE TO:
IF HOMEMADE: Inside lengtl~
Dwelling
Liquid depth
PERMIT NO.
Material Liquid capacity in gallons
Foundation Nearest lot line PERMIT NO.
Total length of lines Trench width Distance between lines
inches
Material beneath tile Total effective absorption area
Depth
inches
PERMIT NO,
Crib depth Total effective absorption area
Building foundation Nearest lot line
Driller Distance to lot line PERMIT NO,
Sewer line Septic tank Absorpt on area(s)
OTHER
PIPE MATERIALS
SOIL TEST RATING
INSTALLER
REMARKS
./ ~ %
APPROVED
q, %,,',y:, ..~ .;, .: .-.:
72-013 (Rev. 3/78)
LEGAL
;.:', 6 4.--. zt. '7 ;::.'. 0
GREA.,ER ANCHORAGE AREA BORC,.,GH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
__ MAILING ADDRESS ~Q,'--~ ~"~-~-d~'~- *~O)~ '?,)~0 PHONE~.".)~;~ (/~'.'.'./~/
LEGAL DESCRIPTION J"* ''') gi ~2~J2~.Ax.,g._,.;.~g~) (.~..x_.~).~.. CA,C.[
INSIDE LENGTH
INSIDE WIDTH
__ LIQUID DEPTH
LIQUID CAPACITY__
GALLONS.
TILE DRAIN FIELD:
DISTANCE FROM WELL
FOUNDATION
NEAREST LOT LINE
TOTAL LENGTH
OF LINES
NUMBER OF LINES DISTANCE BETWEEN LINES TRENCH WIDTH IN. TOTAL EFFECTIVE
ABSORPTION AREA -~"~f~o [ SQ. FT. LENGTH OF EACH LINE
( DEPTH OF FILTER
DEPTN: TOP OF TILE TO FINISH GRADE-'~, MATERIAL BENEATH TILE'~'-"~- 4,~/. ABOVE TILE ~/ IN.
WELL: '
T y p E ~'%~,~
BUILDING
FOUNDATION__
CESSPOOL
APPROVED
CONSTRUCTION ___
NEAREST
LOT LINE ___
__, OTHER SOURCES
DISAPPROVED
~ //'~, DEPTH
NEAREST SEPTIC SEEPAGE
SEWER LINE , TANK , SYSTEM
.REMARKS
DISTANCE FROM:
DISTANCES: ....
DIAGRAM OF SYSTEM
SEWER LINE DEPTH:
p i p E M A T E R i A L :d-.~.~5~.-- _~'~,~,~
LOT SLOPE~_...~'~
i..E:I'.,I(iiTH [::, ]: I'"lE:l',l:i:]; :[ I:i:ll'.,I 3: S 'TI'lIE I...IENI:3't"I-I ,:: :!: l",l I;::'I;!i:IET ::, OF:' TI'Ifil
i3F::' I:;:1 't'I:;i:I;:i'.,IE:II Of;il F'i[T ili'.:ii; "I"HI!;i Iii:,ili?l'l':ll',lE:liiil !i',Eii'l'l.,.l[!:iEii'.,!
f::ll",l[i:, '1'1'-I1!!i li!i:EFFTEiI"I I=d:::' TI.II:~-i I'iii',:':',tiii:i:;:l',,,'f¥1"illEd',l ,:i lilt.,/
bio '.i!;E:'r' I.,.I ~1: DTH I::'Ol:;i'.
f'iil:a:l:::lk,'liii:l... I:::,Ii;!:I:::'TH :[ '_':i: "l"Hlii!: I"1:1: hi I I'll..Jl"'l 17::,lEi:I-:'"l"l'.l ELF.' Gl:~:f:l'v'lii:l.. Edii:'lq.,IJEE2',l "Fl'lliii: EtLITF:'F:iI ..I..
190TTEd"I OF= FI'IIZ E:t:'::E:f:iYf:'IT)'ii::iI'.~ ,:::lJi'..I
GREATER ANCtlOI</\GL AI<J.A [$OROLJG,,
L}epartment of Envirorlmenl. a] Qua Ji Ly
3330 'lC" SLreet
Anchorage, A1 as ka 99503
SOII,S LOG Iq~ROI,ATION TEST
I~XEG'UTIVJ~ BUILDERS~ I~C, . , , D - , R/5/7~
Perfornled for ~ c/ ;,ate ~erTor~:m,.:., ----,--
This form reports: Soils log x Percolation Les[
Depth
0. ~_e. et .....
1 T ~--~-_, ~rk-~i~m~tre-ia! , ~.t'e ......
Oo ~ Oi~I S S i~E
2 - Brown si] t, ramdo~n rock, no s ~.'rld
Si].'~ fraction non-plastic
6
7
7.5
Poorly graded,silty gravel, no
clay, Silt fraction non-plastic
10 - ,-,e?o,o~-
1'1 -
.Poorly 8faded, sandy gravel~ little
12-
or no silt. Fines fraction non-plastic.
~' Class
1.3.Q' _~SCS
"CF"
14-
20.0 Clean~ coarse sand, no silt. USGS Class "SW/SP".
Wa-S"grouncl water encodfi't-qf6-d'F~. _~_~2-_._-T.__T_ 'if yes, at what depth?
'F~T&~)]-a t--i-o~ -F~i~ .............. il[i-n-uTe-.
'.Proposed i ns tall a~l-~- -'B~ge Pi t Drain Fi o Jd X
DepUi of Inlet .................. . Dept'lT~'b6'~'~'m%?--i)it or Lrench 7T5
COMMENTS: ..i)~;~=n~.$9.1=~- $p~v~...p_~p_0m~d.__a_~
130 sq, ~, seepage a,~ea pe~ bedroom,
.......... ~ ...... ~ ......... T~= .............
Performed [~y: / ~,~,~ -,~..~ Certified
Eq-04O ~B/74)
GRE/.,..ER ANCHORAGE AREA BOR
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME
SEPTIC TANK:
DISTANCE
FROM WELL .,k'2'"4~
INSIDE LENGTH
MANUFACTURER ~,,~'¢--~ MATERIAL
/
INSIDE WIDTH~,~____ LIQUID DEPTH
NUMBER OF
COMPARTMENTS /
LIQUID CAPACITY GALLONS.
TILE DRAIN FIELD:
/
DISTANCE FROM WELL//¢~' FOUNDATION ~'~) _
NUMBER OF LINES DISTANCE BETWEEN LINES
ABSORPTION AREA
DEPTH: TOP OF TILE TO FINISH GRADE
TOTAL LENGTH
NEAREST LOT LINE__ / OF LINES
TRENCH WIDTFI~ /IN. TOTAL EFFECTIVE
/
FT. LENGTH OF EACH LINE ~--0
/ DEPTH OF FILTER~
MATERIAL BENEATH TILE ~ IN. ABOVE TILE ~¢ IN.
WELL:
TYPE
BUILDING
FOUNDATION__
CESSPOOL
APPROVED
CONSTRUCTION
NEAREST NEAREST
LOT LINE__, SEWER LINE
OTHER SOURCES__.
DISAPPROVED REMARKS
DEPTH I
SEPTIC SEEPAGE
TANK__ SYSTEM
DISTANCE FROM:
DISTANCES:
I N STA L LED By: ~t-~ ./~.~" ~
SEWER LINE DEPTH:
PIPE MATERIAL: ~-~"~ ~/"
LOT SLOPE:
REMARKS:
Form LQ-032
DIAGRAM OF SYSTEM
J~4 'W DRILLING, Inc.
P. O. Box 4-1224 · 1310C International Airport Road
(907) 274-4611
ANCHORAGE, ALASKA 99509
DRILLING LOG
Well Owner. . E×ecutive Ii, u! lc!~..,.r.~ .Use of Well
' ' ,'...:',,,
Location (address of: Township, Range, Section, if known; or "distance main road, '
Lot 7~ BI]{ 1 ~~ liiJ. J s
Size of casing. 6" .Depth of Hole .I00 feet Cased to 'U,)2.? feet
Static water level P.,O ft. (Abqv.e.) (below) land surface. Finish of well (check one) open end ( ;.: );
Screen ( ); Perforated ( .~:, ).
Describe screen or perforation ';:.J .1.~ ,q~:;..fa l-'o.~:~s,~gt..P,~')~70.'77~, z.), .TBt?O, ....... Bf~a~ :.,."'
Well pumping test at 2~ gallons per (l16fi~) (minute) for ! hours with 10~ ft.
of drawdown from static level. :~.
.... pt~ * 9'75 ·
Date of completion 9 c~,, .. _
WELL LOG
Depth in feet from
ground surface Give details of formations penetrated, size of material color and hardness
10 ,, ~il't~; n,~d~ arave!
.15
~.O
0 TO
JO TO
15 .TO
4,0 TO
414 .TO
5,q .TO
7.) .TO
~f) .TO
90 TO
91 .TO
96 .TQ
99 TO.
__.TO
.- TO.
TO.
4'~
9O
96
99
10,.'3.
" 3--CONTRACTOR
GRE! ER ANCHORAGE AREA BOb UGH
PERMIT NO.
DEPARTMENT OF ~NW.ONMENTA' QUA~.~TY O;::~
SEWAGE DISPOSAL SYSTEM APPLICATION AND PERMIT
NAME OF APPLICANT J v ~ MAILING ADDRESS(.
INSTALLATION LOCATION '~--~'
INSTALLATION OF: SEPTIC TANK
TYPE AND SIZE OF FACILITY TO BE SERVED
FINANCED THROUGH ·
SOil TEST RESULTS // ..'%' (") /'~/r//'~'~'~'
?
SEEPAGE PiT , DRAIN FIELD ., OTHER
'2L/) NOT£, THIS PERI~IIT ,S(~OT YAI.,ID WITHOUT ~;Oli TE:S'f
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENV]RONMI~NTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK ,, SEEPAGE PIT
TO NEAREST LOT LINE.
DRA,N F,ELO
., DRAIN
"
SEEPAGE PIt
ALSO CONSIDER AREA WELLS.
WATER MAIN TO SEPTIC TANK SEEPAGE PIt
DRAIN FIELD ~-
/wo
SEPTIC TANK , SEEPAGE PIT ., DRAIN FIELD
TO RIVERi LAKE, STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION S FEET INTO UNDISTURBED SOil.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIt
FITTED With AIRTIGHT REMOVABLE CAPS,
I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-08 AND THAT THE ABOVE
DESCR]B SYSTEM IS IN ACCORDANCE WITH SAID CODE.
/ / ~' APPLICANT'S SIGNATURE
/' '- (.h W/
I hereby cerli[y that I hove sur'cey .mi,' ~? foil,owing detcribod prop~rpt, Lot ?' ~ck /
Improve~en~ slluated thereon are wl~ln the properly line, and do nor o~erla~ or enc~ach
on ~o pmpe~ ~lng adi~ent thore~ ~a~ no Improvement~ on proper~t lying ud[ac~nl Ihere~
enc~ch on the premi~l la quesl~n ~d thai ~ere are no roa~oy~ tran~rnt~n lh~ or
Municipality of Anchorage
Development Services Department
CERTIFICATE
FOR A
Building Safety Division
On-Site Water & Wastewater Program
.4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
OF ON-SITE SYSTEMS APPROVAL
SINGLE F AHILY DWELLING
0
Parcel I.D. 015-154-25
1. GENERAL INFORMATION
Expiration Date:
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
LAKEWOOD HILLS #4; BLOCK 1, LOT 7
10541 ELIES DRIVE *ANCHORAGE, AK 99507
ELIZABETH GOODRICH Day phone
10541 ELIES DRIVE *ANCHORAGE, AK 99507
346-1433
Day phone
STEPHEN VLAHOVlCH W/ DYNAMIC
Day phone 223-5998
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 3
3. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well · Individual On-site ·
Individual Water Storage [] Individual Holding tank []
Community Class Well [] Community On-site []
Public Water System [] Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems
Approval are valid for 90 days from the date of issue for properties served by'a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
STATEMENT OF INSPECTION BY ENGINEER
As certifieduy ~ my seal affixed hereto and as u,-' "-,,e 'w,u~,un-':~'= u~Le'~' shown below, / 'w,,,y
investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this app#cation,
sho~ that the on-site wa!er supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedroom, s and type of structure indicated herein. I further verify that based on t,he
/nform,,ation obtained from the Municipality of Ancherage f~es and from m,y investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all appficable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Phone 557-6179
Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Date
Engineer's Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
t,~e sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
DSD SIGNATURE
~/ Approved for _~
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations: ~,.~
.... .
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisor7
(Rev. 1 ~/05)
Arsenic Adv sory
Maintenance Agreements
Supplemental Engineer's Report
u ~1 lei
Ao
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description:
WELL DATA
LAKEWOOD HILLS #4; BLOCK 1, LOT 7 Parcel ID: 015-134-25
Well type PRIVATE
Date completed '10/5/11
Total depth 114 ft.
Date of test
Static water level
Well production
WATER SAMPLE RESULTS:
*OLD WELL WAS
DECOMMISSIONED PER UPC.
IfA, B, orC provide PWSID# N/A
Sanitary seal (Y/N) YES
Well Log (Y/N) YES
Wires properly protected (Y/N)
Cased to 114 ft.
Casing height (above ground)
FROM WELL LOG
1 o/3/11
84
ft.
AT INSPECTION
NEW WELL
ft.
10
g.p.m.
g.p.m
Coliform 0 colonies/lO0 mi.
Arsenic: ~ I~ ug./L.
SEPTIC/HOLDING TANK DATA
Nitrate~'O ~- mg./L. Collected by:
Date of sample:
*DOUBLE C/O'S PRIOR TO PUMP VAULT
GEG, Ltd.
Tank Type/Material SEPTIC/STEEL Date installed 9/13-14-/1 1
Tank size 1250 gal. Number of compartments 2 Cleanouts (Y/N) YES
Foundation deanout (Y/N) *YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A
Date of pumping NEW Pumper -
ABSORPTION FIELD DATA I'BELOW EXISTING GRADEI
Date installed 9/15-14/11 Soil rating (g.p.d./ft2or~ 0.8 System type DUAL TRENCHES
Length 2 © 20 = 40ft. Width 2.5 ft. Gravel below pipe 8.0 ff.
Total depth 12.4-9+ ft. Eft. absorption area 64-0 ft2 Monitoring tube YES Depression over field NO
Date of adequacy test NEW Results (Pass/Fail) PASS For 4- bedrooms
Fluid depth in absorption field beforetest - in. Water added - gal. New depth - in.
Elapsed Time: - min. Final fluid depth - in. Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date -
YES
24+ in.
D. 24" ORENCO PUMP VAULT
Date installed 9/13-14/'11
"Pump on" level at 62 in.
Datum TOP OF MH LID
SEPARATION DISTANCES
Size in gallons 78
"Pump off" level at 79 in.
Cycles tested. NEW
SEPARATION DISTANCES FROM WELL ON LOT TO:
100'+
Septic tank/liE station on lot
Absorption field on lot. 100'+
Public sewer main N/'A
Sewer/septic service line 25'+
Animal containment areas 50'+
Manhole/Access (Y/N) YES
High water alarm level at ' 58
Meets alarm & circuit requirements?
Building foundation
Water main
Wells on adjacent lots
On adjacent lots 100'+
On adjacent lots 100'+
Public sewer manhole/cleanout
Holding tank N/'A
Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
5' + Property line 5' +
N/A Water service line 1 O' +
100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation. 10'+
Water service line 10'+ Surface water 100'+
Curtain drain NONE KNOWN Wells on adjacent lots 100'+
YES
Absorption field
Surface water.
in.
F. COMMENTS
N/A
100'+
5'+
100'+
Water main N/'A
Driveway, parking/vehicle storage 10'+
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. GARNESS
Date ) ~ /~/1~
COSA Fee $ c~
Date of Payment
Receipt Number
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
Municipality of Anchorage
Community Development Department
Development Services Division
On-Site Water and Wastewater Program
4700 Elrnore Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
Nitrate Advisory
Certificate of On-Site Systems Approval # osc 111391
A Certificate of On-Site Systems Approval inspection and test of potable
water was recently conducted on the well water supply on Block 1, Lot 7 of
Lakewood Hills #4 subdivision. This inspection revealed a nitrate
concentration of 8.02 milligrams per liter (rog/L) was reported for the
property's well water sample. The Environmental Protection Agency (EPA)
has established a maximum contaminant level (MCL) of 10.0 mg/L for
public drinking water systems. While private wells are not subject to this
regulation, EPA standards are based on existing health information and can
therefore be used to gauge the relative quality of water from private wells.
Please see the attached "Nitrate Fact Sheet" for important information
regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On-
Site Systems Approval.
mm !
0
/
/
i
I
/
10' UTILITY EASEMENT
m
...q
-I
IT1
NOO°O3'12"W 175.00
PROSPECT HEIGHTS, ADDITION No. 4
SGS ReL# 1114938001 y"~
Client Name Gamess Engineering Group, Ltd Printed Date/Time 10/14/2011 9:04
Project Name/# Lakewood Hill~ L7 B1 Collected Date/Time 10/06/2011 16:15
Client Sample ID Lakewood Hills L7 BI Received Date/Time 10/07/2011 12:19
Matrix Drinking Water Technical Director Stel}hen C. Ede
Sample Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Metals by ICP/MS
Arsenic ND 5.00 ug/L EP200.8 C (<10) 10/11/11 10/12/11 NRB
Waters Department
TotalNitrate/Nitrite-N 8.02 0.100 mg/L SM204500NO3-F B (<10) 10/I0/11 AYC
Microbiology Laboratory
Colony Count 2 col/100mL SM20 9222B A (<200) 10/07/11 DLC
Fecal Coliform 0 col/100mL SM20 9222B A (<1) 10/07/11 DLC
Total Coliform 0 col/100mL SM20 9222B A (<I) 10/07/11 DLC
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL ~61N .PI 'F'ti~ Iq,AL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date' //Cf, 7 ) ~:¢~
1. GENERAL INFORMATION
(a) Legal Description (include lot, block, subdivision, section, township, range)
L -7 'G / /-/lit s ;'-d'z/-1
Location (address or directions)
(b) Applicant Name ~E, 0mc~so,:
Applicant Address ~ ~ ¢ ~
(c) Applicant is (check one): Lending Institution ~; Owner/builder Buyer ~; Other ~ (explain);
Telephone: Home &':~z~.¢ ~;,2.2zC-~"Business
?
(d) Lending Institution ,~ Telephone
Address
(e) Real Estate Company and Agent
Address
Telephone
(f)
Mail the HAA to the following address:
3 4 4
TYPE OF RESIDENCE
Single-Family(~ Multi-Family[]
Number of Bedrooms ~
Other
WATER SUPPLY
Individual Well [~ Community [] Public []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite ~ Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2 72-025 (11/84)
ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verity that my investigation of this He'alth
Authority Approval shows that the on-site water supply ar,~,'or v;c, atcwc4c~ dlsposaFsystem is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water suppry
waetewetcr dlspeeel system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
thedateofthisinspection,,,z.×¢er~ +--ko-cc ~'1,~ $-~p-t:,~ E,'~k ~¢~.y Io~ Eoo ~{~ ~ '~h~-
Name of Firm )'h~c~cd tL/..or'~ ~ ~---~__~-- Telephone ----~'~-~'~- ' '~7 (I
Address '-7 I'D..-? (]]) ~ ~-~,,~y
Date ~//'7 /~ (-.¢'
WATER WELL NOTE: This Health Authority Approval inspection merely
certifies that the subject water well produced 150 gallons per
bedroom or more on the date of testing and that certified laboratory
tests showed no presence of coliform bacteria in a sample of that
water. No warantee or certification is expressed or implied
concerning the long term adequacy or safety of the water supply. .~'~ -'"~'~'~"~
-ON:SITE SEWAGF.~E1%~POS~,L SYSTEf~N(~TE: "~h' He~uthority Ap~
i n~ly ce~-~t_ he~~~i spo sa l
date ~.~ as dete~y methods~ve~_by
re~~ MOA fil~;as
n erified durin¢is iffspection/
En
DHEP APPROVAL
Approved for ~'~edrooms by
A~ed Disa~ved
Terms of Conditional Approval
Date
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professionaJ engineer's work.
Page 2 of 2
M(JNIC~PALITy OF ANCHoRA~S
DEPT, Off H~ALT
ENVIRONME~. .... H &
MUNICIPALITY OF ANCHORAGE (MOA) , o ,'~,,~c PROTEC'rlO
HEALTH AUTHORITY APPROVAL (HAA) - Co¥,~ I t~o~.~-[ ~ N
CHECKLIST- FEBRUARY 1984 /1~ 7 ~!
264-4720
Legal Description: /~ "7 ~'~'~ / ~6~//'-~ ¢f'~-
WELL DATA
Well Classification Pr, VcJ~ -~?S/ . ~ ~L/ if A, B, C, D.E.C. Approved (Y/N)
Well Log Present (Y/N) 7 Date Completed
~::~ [P ~ ~ ) } ~' Yield
Depth of Grouting /~//~
Pump Set At (~'~ ~: ~ ~ ~
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
{-~/m ],~ ln,¢~O ~ ; On Adjoining Lots
IO~t~ ; On Adjoining Lots IOo
To Nearest Public Sewer
To Nearest Sewer Service Line on Lot ; Date ~/~
Total Depth ! 0 O Cased to
Static Water Level
Casing Height Above Ground
Electrical Wiring in Conduit (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line
Cleanout/Manhole /,/
Water Sample Collected by
Water Sample Test Results
Comments '-)( ~',~ ¢ 0o¢__.(I
SEPTIC/HOLDING TANK DATA
Size /~ ~'-O No. of Compartments ~
Air-tight Caps (Y/N) ~ Foundation Cleanout (Y/N)
Date Last Pumped I O ~v r-s.
/%///~ ;for
Temporary Holding Tank Permit (Y/N)
To Building Foundation
To Disposal Field
Date Installed ~/7 E
Standpipes (Y/N) ~
Depression over Tank (Y/N)
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High-Water Alarm (Y/N)
Separation Distances from Septic/Holding Tank:
To Water-Supply Well g&~ ~ol,/
To Property Line / ~-
To Water Main/Service Line ~O -- 2.0 To Stream, Pond, Lake, or Major Drainage
Course
Page 1 of 2
72-026(11184}
Soils Rating in Absorption Strata j
Datelnstalled ~/'~¢' ¢-.~-¢-, ~ ~ /7~...~~'''~'
Width of Field ~
Cq~ f or-'te~
uare Feet of Absorption Area '¢
Depression over Field (Y/N) 5'~.~
Results of Last Adequacy Test
Separation Distance from Absorption Field:
To Water-Supply Well /O O ± ~,¢1~1
Type of System Design
Length of Field
Depth of Field '~'f ~'
Gravel Bed Thickness '"'"'-
Standpipes Present'(Y/N)
Date of Last Adequacy Test
;s "-'~O To Property Line
To Building Foundation
Lot "~ ,~O / 4-
f
To Water Main/Service Line ~'
To Stream/Pond/Lake/or Major Drainage Course
,?
To Driveway, Parking Area, or Vehicle Storage Area
Comments ~'~' ¢ ¢'~ '"~-~¢~c ~gJ rm~
To Existing or Abandoned System on
; On Adjoining Lots ~'?~O /
To Cutbank (if present)
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes ..(Y/N)
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
Comment's
** Check Permitted Bedroom Rating Against HAA Request **
I certify tha~..~ec¢¢ve~:nformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed '.,'~---'~ .~-~~ Date
Company /~,¢~.~.~'~}~o,-~¢ ,~----~'.~-,-- MOA No,
Receipt No. 3'7 ~'~'~ ~
Date of Payment
Amount: $
Page 2 of 2
72-026 (11/84}
NlunicipalitYof
Anchorage
P.O. BoX 196650
ANCHORAGE, ALASKA 99519-6650
(907) 264-4111
TONY KNOWLES,
MA YOI~
DEPARTMENT OF HEALTH & HUMAN SERVICES
July 2, 1986
Neil Hawthorne, P.E.
NHawthorne-Engineering
7127 Old Seward Highway
Anchorage, Alaska 99503
Subject: Lot 7 Block 1 Lakewood Hills Subdivision #4
Waiver Request, WR86-085
Dear Mr. Hawthorne:
Your request for a waiver for the subject lot has been denied. Available
information on the soils and hydrogeological conditions on the subject
lot indicated that a waiver of the 100 foot separation requirement was
not warranted.
Sincerely,
Stephen S. Morris
Civil Engineer
On-site Services
SSM/ljw
NI-IAWTHORNE-ENGINEERING
June 26, 1985
Mr. Steven Morris
Anchorage Dept. of Health ~ Human Services
825 L Street
Anchorage, AK 99501
Re: L7 B1Lakewood Hills #4, S13, T12N, R3W
7127 OlD SEWARD HIGHWAY
ANCHORAGE, ALASI~ 99502
- · OF ~x,~,_, -
~NVIRONM~NTAL-~-,,-u t PROTfiCTIoN &
REC[IVE
Dear Steve:
This letter is a result of a conditional health authority
approval on the above property and my recent site investigation. The
enclosed sketch shows sewage system appurtenances and the well. We
were finally able to verify pipe connections, etc. with water and a
power snake.
As you can see, the well is 52 feet from the septic tank. This
was apparently approved in August, 1976 by your department after a
second trench was installed. The previous paperwork is enclosed.
The client, of course, would like a waiver for the septic tank to
well separation distance. If the enclosuress don't answer all of your
questions, please call.
NH:ck
Enclosures
NlunicipahtYof
Anchorage
P.O. BO,,, 196650
ANCHORAGE, ALASKA 99519-6650
(907) 264-4111
TONY KNOWLES,
MA YOR
DEPARTMENT OF HEALTH & HUMAN SERVICES
April 14, 1986
Neil Hawthorne, P.E.
NHawthorne-Engineering
7127 Old Seward Highway
Anchorage, Alasga 99502
Subject: Lot 7 Block 1Lakewood Hills Subdivision #4
Waiver Request, WR86-042
Dear Mr. Hawthorne:
Your request for a waiver of well to septic system separation distances
cannot be considered until more information is supplied. As you have
stated in your request, the exact locations of the septic system
components cannot be made until breakup.
A conditional Health Authority Approval can be granted for the subject
property under the following conditions:
Funds shall be escrowed to cover the cost of relocating the well.
(You have estimated this cost at~$6,000)
A formal, completed waiver request for the subject property must
be submitted to the department by May 15, 1986.
If the waiver request is denied, relocation of the well and/or septic
system componehts must be accomplished prior to July 1, 1986.
Failure to comply with the conditions of the Health Authority Approval will
result in its in~ediate revocation.
Sincerely,
Step~~en S'7 Mo r~r'is
Civil Engineer
On-site Services
SSM/ljw
NHAWTHORNE-ENGINEERING
April 3, 1986
Ms. Susan Oswalt
Department of Health and Human Services
Municipality of Anchorage
826 L Street
Anchorage, Alaska 99501
7127 OLD SEWARD HIghWAY
.",.CHORALE, ,
907-344-47! 1DF, PT, OF HEALTH &
I]NVIP, ONMI~NTAL P~OTECTION
ECEIVED
RE: Lot 7 Block 1 Lakewood tlills #4, S13, T12N, R3W
Dear Ms. Oswalt;
This request for a separation distance waiver and a
conditional health authority approval is a little different.
Strange, in fact. I have gone through the file and looked at the
site and still am not sure how the on-site wastewater system was
built or connected (or approved).
Apparently, the first tank and drainfield were installed at
about the same time as the well; September, 1975. The well
wasn't approved becat~se of the separation distances, so a new
trench was constructed and was inspected August 31, 1976. That
inspection shows the trench to be 95 feet from the well, although
my measurements indicate that it may be 100 feet away.
The septic tank, however, is only 53 feet or so from the
well if it is still located where the original inspection showed
it. There are no pipes visible at this time so we want to expose
them after breakup.
Due to 2 feet of snow and the frozen ground, the owner has
requested that I ask for a conditional Health Authority Approval.
In the worst case, I estimate that relocating the entire septic
system and furnishing a new tank will cost about $6000 including
engineering, assuming the 1975 soils test is fairly accurate.
That price includes properly abandoning the old system, driveway
repairs, etc.
I can't locate all the neighboring wells and septic systems
w~th the snow cover, but relocating the well instead of the
septic tank may be the best choice if separation distances allow.
That action would leave two full sized drainfields on the lot
available for wastewater disposal. A new well and service line
should cost less than the $6000 mentioned ¢~bove, and both
upgrades would not be required. In other words, if the septic
system is upgraded, the well will not have to be moved and vice
versa.
When breakup comes, I can more easily determine the exact
location of the 1976 trench. As I said, it now appears to be lO0
feet from the well although the inspection report shows 95 feet.
If the well remains where it is, we should probably have a waiver
of 'the 100 foot distance requirement between the well and
drainfield. It's possible that the drainfield is arched which I
can't tell from the surface. I have included the well log for
your information but you may want to wait until June to see which
improvement is undertaken.
Th~s./
Neil Itawthorne
'x
MUNICIPALITY OF ANCHORAGE ~qVIRONM~3qTAL
) DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
825 L Street- Anchorage, Alaska 99501 HAY 2,
ENVIRONMENTAL ENGINEERING DIVISION
Telephone 264-4720 .RECEi /ED
REOUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
DIREOTIONS~ Complete all parts on page 1, Incomplete requests will not be processed, Please allow ten (10) days for processing,
1, PROPERTY OWNER 1 PHONE
Merrill Lynch Relocation Mortgage (Wayne Pighin
MAI LING ADDRESS
PROPERTY RESIDENT (If different from above) PHONE
2, BUYER PHONE
MAILING ADDRESS
3. LENDING INSTITUTION I PHONE
I
MAILING ADDRESS
4. REALTOR/AGENT I PHONE
Jack White Company % Elliot LawsonJ 277-1553
MAI LING ADDR ESS
3201 C Street - Calais II 995,03 .........
5, LEGAL DESCRIPTION
Lot 7 Block 1 Lakewood Hills Subdivision #4
STREET LOCATION
Elies Drive
6, TYPE OF RESIDENCE
SINGLE FAMILY
[] MULTIPLE FAMILY
plus a den
NUMBER OF BEDROOMS
[] One [] Four
~ Two [] Five
[] Three [] Six
[] Other
7, WATER SUPPLY
INDIVIDUAL*
[] COMMUNITY
[] PUBLIC UTILITY
* ATTACH WELL LOG. A well log is required for all wells drilled
since June 1975. For wells drilled prior to that date, give well
depth (attach log if available.)
8. SEWAGE DISPOSAL SYS'rEM
~ INDIVIDUAL/ON-SITE**
[] PUBLIC UTILITY
**If individual/on-site, give installation date
If system is over two (2) years old an adequacy test is required
by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010(3/78)
THIS SIDE FOR OFFICIAL USE ONLY
DATE RECEIVED
INSPECTION APPOINTMENTS
TIME TIME TIME
DATE DATE DATE
INSPECTOR INSPECTOR INSPECTOR
DIRECTIONS:
1, TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER .
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2. WATER SUPPLY
[] INDIVIDUAL DEPTH OF WELL
r~ COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[] INDIVIDUAL/ON -SITE DATE INSTALLED
[]PUBLIC UTILITY
Connection Verified INSTALLER
[]Septic Tank or E~Holding Tank
Size: If Tank is homemade SOILS RATING
give dimensions: L ~-~
TYPE OF TANK MANUFACTURER
4. DISTANCES Septic/Holding Tank Absorption Area Sewer Line I Nearest Lot Line
I
WELL TO:
Absorption Area to nearest Lot Line
[] CONDITIONAL APPROVAL (letter must a/./~pany certificate)
[~ DISAPPROVED .~ I/ .~.~.
LEGAL DESCRIPTION
72-010 (Rev. 3/78)
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
2510 East Tudor Road, Anchorage, Alaska 99504 276-2221
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
1. Type of Inspection: CMRO VA FHA CONV
2. Property Owner: MERRILL LYNCH RELOCATION MGT. INC. (Wayne Pighin)
Mailing Address: see A~ent Info below Day Phone:
3. Name of Buyer: No buyer yet .... just 11stlng property
xxxx
Mailing Address:
Name of Lending Institution:
Mailing Address:
Day Phone:.
No bank yet .... just listing property
Phone:
5. Name of Realtor or Agent: JACK WHITE COMPANY (Attn: ELLIOT LAWSON)
Mailing Address: 3201 C Street~ Anchorage, AK Phone: 277-1553
6. Legal Description: Lot 7, Block 1, Lakewood Hills Sub. #4
Location: On Elies Drive~ just off Upper O'Malley Road .... house sits
back from street .... has natural wood siding .... approx. 5th lot on right
hand side of Elies Drive.
7. Type of Facility to be Inspected: Single-family
8. Water Supply
Type of Supply: Public Utility.
If Individual, number of dwellings presently served
If Individual, depth of well unknown
9. Sewage Disposal System
Type of System:
If Individual, date of installation
No. Bdrms, 2 plus Den(no window]
XXXXX Well
,Individual
One
Public Utility Individual (on-site) xxxx
unknown.., but home blt. in approx. 1975 or 1st part
of 1976
72 003(3/76)
May 1, 1979
?:Li'''~' 't".,_~'.:, 1, .... PROPERTY, OWNER, .· , "~!.~ · . ,.,,,.'"'~;{ ~:~;'~..J-~<~., ,. , ~.-.:,:,:,,:~' ;,-. ,". '. . '!.'-. . -~. ,'~. .. ,!-.:;' _ -3'...-:., ..-,: ,?':':' ;-. ,. "' ~'::'~"
Merrill Lynch Relocation Mortgage(Wayne P~ghin)
~ ,' ..... MA LNG ADDRESS ..:. .... -~'~,~,:~::~:~'.~..~ .... ' _ .1. :~,~ . _ .... ~ ~ .... , .... i ~ ..
¥?~.... :. .... .~ ~,,,~,1...~:.., - .., . ~3..,..~.~,. . . ~. .. . ..- .: , . ...~ ~..> .f .
' ~ - .,.._,..~,,~, _.. ,. -
Lot 7 Bl°Ck'l La'k~W6od Hills Subdivision #4
SINGLE FAMILY RESIDENCE'_- U3 OTHER (Describe) '
5. SEWAGE DISPOSAL - · · '. , .- .. · -. .....
· x~x iNDiViDUAL/ON.SiTE,, ;:.--... ......:.~: -,; ._.. ':3, :. :..;..', .... . .,.- /: '.
PUB LIC UTI LITY' '.?':.'., '""-:. ';/.. ': ~ ;,~,.~,_., . --
- r~ HoL~ING·~ANK (~ai'n~enanc~ R~'qui~ed)- . .
~'.-. - ':-'i?' -' E~3' APPROVED FOR"'"'"'-:,.: 'BEDROOMS,'.-',' '-~"i ~ ,.,,i~ ! ~_
"~':.'-: ;":/:-:~' -CONDjTIONA~"AppROvAL (see AttaChed) ~ '
":' · "-':~ ~x~IsAPP ROV ED ' ' ??/' ' ' -:' ~-' .- '~'/-~;~'?'~:'~( "- -,~'-,'"" '- ~':',:~ '"-'
We hsve-not received the p~ping receipt in t~is office;
BY (TITLE) .... ~ . · "
May 29, 197
DATE
72~14 (3/78)
MUNICIPALITY OF ANOHORAGE .~ ~_.~/i~(..
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTEOTION
~//~j ~,.~..~ 825 L Street - Anchorage. Alaska 99501
ENVIRONMENTAL ENGINEERING DIVISION
Telephone 264-4720
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PROPERTY OWNER PHONE (work)
SANTEE, Scott A. & Rhea -' 278-4581 X281
MAILING ADDRESS
SRA Box 95C Anchorage, Alaska 99509
PROPERTY RESIDENT (If different from above) PHONE
NHN Elias Drive Anchorage, Alaska
2, BUYER PHONE
PIGHIN, Wayne R. & Barbara T. 274-7408
MAILING ADDRESS
1300 West 7th Avenue ~Jl01 Anchorage, Alaska 99501
3, LENDING INSTITUTION I PHONE
Alaska National Bank1 278-4581
MAILING ADDRESS
Pouch 7-010 Calais II Anchorage, Alaska 99510
4, REALTOR/AGENT ] PHONE
Grace Oakley] 277-7556
MAILING ADDRESS
~m~ali-'RealtyL ' 2458 Sprucewood Anchorage, Alaska
5. LEGAL DESCRIPTION
Lot 7, Block 1, Lakewood Hills S/D
STREET LOCATION
NHN Elias Drive Off Upper O'Malley Road
6, TYPE OF RESIDENCE
SINGLE FAMILY
--I MULTIPLE FAMILY
NUMBER OFBEDROOMS
[] One J~] Four
[] Two [] Five
[] Three r~ Six
[] Other
7. WATER SUPPLY [] INDIVIDUAL*
[] COMMUNITY
[] PUBLIC UTILITY
* ATTACH WELL LOG. A well log is required for all wells drillea
since June 1975. For wells drilled prior to that date, give well
depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
{~ INDIVI DUAL/ON-SITE** ** f individual/on-site, give installation date
f system's over two (2) years old an adequacy test is reouired
[] PUBLIC UTI LITY by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010(3/78)
NiUNICIPALIT¥ OF ANC' .......
DEPT. OF Hr*t
ENVIRONM!::-, .~,L ,-'.
.RECEIVED
THIS SIDE FOR OFFICIAL USE ONL
DATE RECEIVED
INSPECTION APPOINTMENTS
TIME TIME TIME
DATE DATE DATE
INSPECT% ~-~' INSPECTOR INSPECTOR
DIRECTIONS;
1. TYPE OF RESIDENCE ~ NUMBBR OF BEDROOMS
~ SINGLE FAMILY ~ ONE ~ THREE ~ FIVE ~ OTHER
~ MULTIPLE FAM[LY ~ TWO ~ FOUR ~ SIX
PERMIT NUMBER
2. WATER SUPPLY
~ INDIVIDUAL DEPTH OF WELL
~ COMMUNITY
DATE DRILLED
~ PUBLIC UTILITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
~ INDIVIDUAL/ON -SITE DATE lUSTALLfiD~
~PUBLIC UTILITY
Connection Verified INSTALLER
~eptic Tank or ~Holdin~ Tank
Size: ~ 0 oD If Tank is homemade 801kS
eve dimensions:
TYPE OF TAN O ~
TOTAL A~SORPTION AREA MATERIAL
4, DISTANCESwELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line
Absorption Area to nearest Lot Line
~ CO~DITIO~Ak A~BOVAk {letter must accompan~ cerdficato)
~ DISA~BOVfiD
DATE BY (Title}
LEGAL DESCRIPTION
72-010 (Rev. 3/78)
GREATER-ANCHORAGE -AREA -BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
Date Received January 6, 1976
Time of Inspection
Date of Inspection ~Jg/) ~ /~/~
REQUEST FOR APPROVAL OF ~, -
INDIVIDUAL SEWER & WATER FACILITIES
FOR /.kD/_/j37
' ' Cony. ~
]. Appr0va] requested by: First National Bank of Anchorage
Mailing Address: Post Office Box 720, 99510 Phone:
2. Property Owner: E×ecutive Bmilders Phone:
4.
5.
6.
V
279-4481 x 231
333-8754
Mailing Address: 8507 Peck, Anchorage
Legal Description: Lot 7 Block 1 Lakewood Hills t~4
Location: Eli~s Street - Anchorage
C. Construction
Sewage Disposal System:
A. Installed
Type of facility to be inspected Single Family No. of bedrooms
Well Data: Individual~O~~ 7F~?~~f
A. Type Z~g~' B. Depth
D. Bacterial Analysis
On-site system
B. Installer
C. Septic Tank: 1. Size
D. Seepage Pit: 1. Absorption Area
E. Disposal Field: Total length of lines
Distances:
A. Well to: Septic tank
Nearest lot line
B. Foundation to septic tank
2. Manufacturer
2. Material
, Absorption area
, Other contamination
, Absorption area
, Sewer Lines ,
C. Absorption area to nearest lot line
EQ-034 (1/74) Page 1 of two pages
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 "C" Street, Anchora.qe, Alaska 99503 - 274-4561
MUNiCi?ALI1Y OF ANCHORAQE
DEPAR'[MENT OF HEALTH &
ENVIRONMENF/kL pp, o r.}CTiON
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
*** PLEASE SEE BELOW FOR ENTRY INSTRUCTIONS
Type of I nsl)ection: CMFIO VA FFIA
,J^N 6 1976
RECEIVED
CONV ××
Property Owner: E×e¢.H~-~ va gl~ 1 rlpl"R
Mailing Address: BSa7 ]~,~,-~-, 4~ch~rage, Alaska
Day Phone 333 8754
3. Name of Buyer: Norman D. Stocks
Mailing Address: P. O. Box 720
5. Name of Real(or Or Agent:_ Alaska Assbciated Realty
Mailing Address: 831 B
Mailing Address: c/o Ralph M. Parsons, 3201 "C" St. Day Phone 276 3868
Name or Lending Institution: The First National Bank of Anchorage
Phone 279-4481 x 231
Phone 274 3556
6. Legal Description: Lot 7, Block 1, Lakewood Hills # 4
Location;. Elias Street, Anchorage, Alaska
'7. Type of Facility to be inspected:
8. Water Supply
Type of Sqpply: Public Utility
If Individual, number of dwellings presently served
If Individual, depth of well
9. Sewage Disposal System
Type of System: Public Utility
If Individual, date of installation
***The purchaser, Mr. Stocks, now occupies the property.
276-3868 to gain entry to the premises.
Private Well& Septic TanJi_ No. Bdrms. 2
Individual
1
private well
Individual (on-site) on site
Please call him at work,
EQ*037 (1/74)
Page 2 of two pages - Ret st for Approval of Individual
Legal Description Lot 7 Block 1 Lakewood Hills ~4
~r & Water Facilities
/ ,
Approve~ Disapprove Date ,.~-~//~../~2~
Approval ~Valid for one year from date sign~/ '
Greater Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
c'ertify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED Date
EQ-034 (1/74)
2~4~4561
.4.t
D]EPT. O~ ~N¥1RONM~NT~L CONSER¥~kT~ON
SOUTHCEIVTRAL REDIONA{_ OFF/CE
JAY S. HAMMOND, Governor
/r 338 DENALI STREET
MACKA Y gUI L DING- ROOM'~flO:
ANCHORAGE 99501
February 4, 1976
Mr. Ro].f Strickland
Chief Sanitarian
Anchorage Municipality
2510 E. Tudor Road
Anchorage, AK 99507
Subject: Lot 7, Block 4, Lakewood Hill Subdivision
Dear Mr. Strickland:
We have reviewed the facts on the systems on the subject
property and feel we cannot approve Lhe well at the distance
i~ is now loca-~ed from the problem ~ewage disposal system°
Sincerely,
Kyle Jo Cherry,
Regional Emvironmental Supervisor
K~C/sv
cc: Norm Jol]y_.