Loading...
HomeMy WebLinkAboutLAURITZ LT 1 DEPT. OF ENVIRONMENTAL CONSERVATION DIVISION OF ENVIRONMENTAL HEALTH DRINKING WATER AND WASTEWATER PROGRAM $55 CORDOVA STREET ANCHORAGE, AK 99501 http://www.state.ak.us/dee/home/htm Jeffi'ey A. Garness, P.E. Alaska Water & Wastewater Consultants, Inc. 7320 East Chester Heights Circle Anchorage, Alaska 99504 TONYKNOWLES, GOVERNOR Telephone: (907) 269-7696 Fax: (907) 269-7696 October 29,1[~1E C E ! V E D NOV 5; 1998 Municipality of/),nchora§G Dept. Health & Human 8orvico~ Subject: Lot 1, Lauritz Subdivision, Anchorage, Alaska, Domestic Wastewater System (Holding tank), ADEC Project Number 390, Plan Review Dear Mr. Garness: I have reviewed your October 22, 1998 submittal regarding a domestic wastewater system, consisting of a 4000 gallon holding tank and sewer service lines for a six-bedroom duplex in the Lauritz Subdivision. Based on this review, I have the following comments. Wastewater From the submitted information and our telephone conversations, it appears that the planned system will meet State Wastewater Disposal Regulations and guidelines. Based on the soil condition, from the test results you submitted, the use of a subsurface domestic wastewater disposal system is precluded. The 4000-gallon capacity of the holding tank will meet the volume of wastewater produced without modifications. Therefore, the proposed system to serve the six- bedroom duplex located on the above-referenced property is temporarily approved for the concerns of this Department. A Construction Certificate, constituting this temporary approval, is enclosed. Therefore, subject to the following requirements, the construction plans for the proposed wastewater disposal system are approved for one year, in accordance with 18 AAC 72, Wastewater Disposal Regulations: The holding tank will be used for a maximum of one year, which allows adequate time for the owner to extend city sewer service to the above referenced property. Jeff Garness, P.E. 2 October 29, 1998 2. The holding tank must be regularly serviced. Complete as-built drawings (plan and profile view) of the wastewater disposal system will need to be submitted to the Department under the stamp of a P.E. The submitted as-built drawings will need to verify placement of all components of the wastewater disposal system. Due to the limited space on the site the as-built drawings will need to verify horizontal separation distances. As discussed during an October 27, 1998 telephone conversation with Nicola Metzger of this department, you stated based on the 60-foot width of Lots 1 and 2, the minimum separation distance of 75 feet from the private well on Lot 3 to the proposed holding tank should be meet. Waiver of Separation Distance You have requested the Department waive the separation distance between the Class 'C' Public Water System and the private sewer service line from 75 feet to approximately 55 feet. I have reviewed the information submitted and find the requested waiver is acceptable. Therefore, in accordance with the provisions of 18 AAC 72.035, the following separation distance is granted: The separation between the Class 'C' Public Water System source and the private sewer service line has been waived from 75 feet to 55 feet. This waiver is valid if the following requirements are meet at the time of installation: The existing sewer service line is replaced with cast iron pipe until outside the 75- foot radius of the Class 'C' Public Water System. 2. All the joints of the private sewer service line are shrink-wrapped. The private sewer service line is pressure tested after installation and prior to burial. Drinking Water From the submitted information and our telephone conversations, the Class 'C' Public Water System is not an approved water system. To help expedite the approval of the system, a Plan Approval Checklist for Class 'C' Public Water System is enclosed. The checklist highlights all the necessary requirements for approving the water system. These approvals do not imply the granting of any additional authorizations, nor obligate any Jeff Garness, P.E. 3 October 29, 1998 state, federal, or local regulatory body to grant required authorizations. The State Wastewater Disposal Regulations require fees for plan reviews of domestic wastewater disposal systems and waivers. The total fee required for this project is $525.00. You have already paid $295.00 for the plan review portion of the project. The fee invoice for the waiver separation is enclosed. Please submit fee payment of $230.00 to this office. Thank you for your coordination with this Department. If you have any questions, please do not hesitate to contact me. Enclosures: As Stated Environmental Engineer Cc: Don Keefer, P.E. AWWU w/o enclosures Jim Cross, P.E. MOA/DHHS w/o enclosures MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 2.64-4720 QN-SITE SEWAGE DISPOSAl.. SYSTEM AND/OR WELL INSPECTION REPORT MAILING ADDRESS -~ DESCRIPTION LOCATION DISTANCE~TO: I O 0 Manufacturer /Liq. capacity in gallons/ IF ROMEMADE: DISTANCE TO:~1Well Absorpti~)n area Dwelling // '~'~(~} / Material Inside length Width NO, OFBEDROOMS PEBMIT NO. No. of ?r~artments.. Liquid depth Dwelling PERMIT NO. Manufacturer I Material Liquid capacity in gallons DISTANCE TO: Well Foundation INearest lot line PERMIT NO. No. of lines Lengt ~ of each line Total length of lines [ Trench width inches Distance between lines Top of tile to finish grade Material beneath tile Total effective absorption area inches Length Width Depth PERMIT NO. Type of crib Crib diameter Crib depth Total effective absorption__ area DISTANCE TO: Well Building foundation Nearest lot line Class Depth Driller Distance to io~i~-e ~ERMIT NO, DISTANCE TO: Building four~dation Sewer line i [Absorption area(s) OTHER PIPE MATERIALS SOIL TEST RATING INSTALLER R EMAR KS DATE LEGAL 72-013 (Rev. 3/78) 0 I"-~ ..... S :E T E: F'ERMIT NO. ( 800408 ::, RF'PL I CFINT LOCFI'T' I ON I._EGRI- DON MRY ]"LI[:,O R RI:'. LOT :!. I. RLIRI:TZ SUB ' " ~TE,,TIOH DEF'RF::THENT F FIERt/f'H RND ENVIRC~NHEI",ITFIL "' ,: ...."L.. S T R E E T, RNC HORFIGE., RK. '.5~'J. 31 594'9 E. 42:RE:, RVE. '~..--" .... 2.44-t564 /-- LOT SIZE i0000 5QURRE FEEl' TYF:'E OF SOIL FIE:SORF:'TION SYSTEH IS: DF.':RINFrIE:L.[:' MRXIHtJf"I NUHBER OF E~E]}F..'OOI'4S = 5 SOIL RRI"ING (SQ FTTE:R.'.',= 150 THE REQI.JIRE[.~ SIZE OF THE SOIL RB'.SORPTION SYSTEM IS: ' '::""-:" ~F.'F~"..."E~ ~.':.:,EE.,F' ~ H ......::IL,. THE LENGTH [:,IMENSICff.,I IS THE EENGTH (IN FEET) OF THE TRENCH OR DRFIINFIEL[:,. THE [:,EPTH OF 8 TRENCH OR PIT IS THE DISTFINCE BE'I"NEEN TFIE SURFRCE OF THE I]i[~OU['~[:' FIH[:' l"HE BOTTOM OF:' THE EXCRVRTION ,::IN FEEl'). THE GRRVEL DEPTH ZS THE MINIMUM DEPTH OF GRRVEL BETMEEN THE OUTFRLL PIPE RND THE BOTTOM OF THE EXCRYRTZON (IN FEET). F'ERMIT RPPLIC:RNT HR'_""; THE RESF'ONSIBILITY TO INFORM THIS [:,EPRRTMENT DURING THE INSTRLLFiTION INSPECTIONS OF RNY I,.IEI_I....5 R[:,JRCENT TO THIS PROPERTY RHE:, ]'HE NUMBER OF RESIDENCES 'fliRT TFIE WELL WILL SERVE. ................. 'T [..,..~ 0 ,:" ;~ ::, :E. ~'-,,~ 2~'; F" EE C: T' Z 0 I'B ."~ FI F~: E F...' EE ~:Z:.~ El ][ ~." E' E::. ................... BFICKFIL. LING OF' FINY SYSTEM WITHOUT FINRL INSF'ECTION RND RPPRO',,,'RL BY THIS DEF'RF..'THENT I,.IILL. BE SUBJECT TO F'ROSECUTION. MINIMUM [:,IS,]"RNIZE BETI.,.IEEN F:I NELL. RN[:, RN"r' ON-SITE SEI4RGE DISF:'CISRL. SYSTEM IS 10E~ FEET FOR FI PRI',,,'RTE WELL OR :L50 TO 2r.~0 FEET FROM R PUE:LIC I,.IELL [:,EPENDING UFu3N THE TYPE OF F'UBLIC WELL MINIP1UH DISTFINCE FROM FI PRIVFITE NELL TO R F:'RIVRTE SEI.,.IER LINE IS 25 FEET F:IND TO R COMMUNITY SENEF.: LINE IS 7'5 FEET. OTHER REC&JIREMENTS MRY RPPL. Y. SPECIFICRTIONS RND CONSTRUCTION [:,IFIGRRMS RRE Ft',,,'RIL. FIBI~E TO INSURE PROF'ER INSTRL/.RTION. I C':ERTIF'? I'HRT ::L.: I Ar,1 FRHILIFtR WITH THE REQIJlREMENT':; FOR I-iN-SITE SENEF.'.S RND NELLS RS 5ET FORTH BY THE HUNICIPF-ILITY OF FINCHORRGE. 2: I P.III_I_ IN':;TFILL. THE S'¢STEM IN F~ISCCIF.'.[:,RNCE NITFI THE CO[:,E.S. ]:: I UN[:,ER?.,TFIN[:, THFIT THE ON-SITE SEWEF.: SYSTEM MRY REQUIF.:E ENLRRGE::~IENT. I[$'-,TFIE RESI[:,E;NI.T.:E IS REMCIE:,ELE[:, 'FCI INC.:LIJ[:,E MOF.:E THI=IN ~ EE[:,F.""~I'.t'-~ 0/0) ¢O/,,J ~%/~,£~'~4e0 /E~ i ....................... .).J /-}. · /) ~ ~ AF'PL I F:F:IN;F' /E:'Otq'~fFZl"r" z~/- ~]x~,.~t~., C~,4,~zf,CP &.> I<.~- . ,=. .... .. , . ,. -. - . , . , , ... lay/:r' /-'V l SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Po.ch 6-650, Anchorage, Alaska 99502 276-2221 SOILS LOG- PERCOLATION TEST [] PERCOLATION TEST 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DATE PERFORMED: j,. /,, y ?// q ¢ ? SITE PLAN SLOPE WAS GROUND WATER L ENCOUNTERED? 0 ~___.. ]P Gross Net Depth to Net Reading Date Time Time Water Drop 20 PERCOLATION RATE .~_¢,~_ rc~ "~'~ ~, ~J~&t as/inch ) TEST RUN BETWEEN · -' DAI:'E RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME / DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION DEPT. OF 825 L Street - Anchorage, Alaska 99501 ENVIRONMENI'AL P;;OTECTION ENVIRONMENTAL SANITATION DIVISION AU~ 6 1980 Telephone 264-4720 DIRECTIONS: Complete all parts o~t page 1. Incomplete requests will not be processed. Please aJlow ten {10) days for processing. 1, PROPERTY OWNER ~ PHONE MAILING ADDRESS 2. BUYER PHONE I PHONE MAILING ADDRESS 4, ~EALTOR/A~ENT I PHONE MAILINO ADDRESS J ' 5, LEGAL DESCRIPTION STREET LOCATION 6, TYPE OF RESIDENCE NUMBER OF~BEDROOMS [] One [] Four [] SINGLE FAMILY [] Two ;J~ Five ~, MULTIPLE FAMILY [] Three I-] Six Other 7. WATER SUPPLY INDIVIDUAL~ [] COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG. A well lo§ is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach Icg if available.) 8. SEWAGE DISPOSAL SYSTEM '1~ INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6/79) THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY [] INDIVI DUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE INSTALLED E~] PUBLIC UTILITY Connection Verified INSTALLER []Septic Tank or E~HoldingTank Size: If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5, COMMENTS ~PPROVED FOR -~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED BY //'~// 72-010 (Rev. 6/79) ANCHORAGE, ALASKA 9950'1 (907) 264-4111 GI:QI~(NF M. St)I_LIVAN, N1AY()[I OEPAIiI'tvlFN] O[ Ht,AI I-tt ANt) ENVII]ONMFNI'A[ pI:IOTI--CIION August 8, 1980 Don/Barbara May 5949 East 43 Avenue Anchorage, Alaska 99504 Subject: Lot ~ Lauritz Subdivisio~ Please make reference to the enclosed copy of a letter sent to you on September 12, 1979. This department cannot give approval until the three(3) items mentioned have been completed. Also, after the well has been upgraded, a water sample will need to be obtained for bacterial analysis. If there are any further questions, please call this department at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/ljw cc: Security Pacific Mortgage 1011 East Tudor Road - Suite 190 Dan F. Huckabay Star Route A Box 2572 99507 99503 MUNICIPALITY OF ANCHORAGE MUNICIPAL,tTY OF ANCHORAGE '" ~'~' ) DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION DFPT, OF ~!':".l,'lH & 825 L Street - Anchorage, Alaska 99501 ~NVIRONMEN]'AI_ F~OTECTION ENVIRONMENTAL ENGINEERING DIVISION AU~ 2 0 I079 Telephone 264-4720 DIR~S; Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. ~OPE~TY/~ OWNER PHONE PROPERTY RESIDENT (If different from above) PHQN~ 2, BUYER PHONE MAILING ADDRESS 3~ING~~INSTITUTION~ f ~ I PHONE ~ILING~DDRESS 4. REALTOR/AGENT ~ PHONE MAILING ADDRESS STREET LOCATION - ~ ~' L~Y'- SINGLE FAMILY ~ ~ - ~;~ MULTIPLI: FAMILY 7. IA'~ SUPPLY '~. ~ COMMUNITY [] PUBLIC UTILITY NUMBER OF BEDROOMS [] One [~1 Four [] Two I--I Five ~'~hree [] Six [] Other * ATTACH WELL LOG. A well Icg is required for all wells drilled since June 1975. For wells drilled prior to that date,~give well depth (attach Icg if available.) If individual/on-site, give installation data /~ 7 , 8. SEWAGE DISPOSAL SYSTEM [~1 ~ DIVI DUAL/ON.SITE~' If system is over two (2) years old an adequacy test is required [] PUBLIC UTI LITY by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR I NSP ECTOR DIRECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL ~ COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVI DUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER []Septic Tank or [] Holding Tank Size: If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES Septic/Holding Taok Absorption Area ISawer Line Nearest Lot Line I WELL TO: Absorption Area to nearest Lot Line 5. COMMENTS [] APPROVED FOR BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) __ ~ DISAPPROVED " ' DATE BY (Title) J2 LEGAL DESCRIPTION 72-010 {Rev. 3/78) Auqust 23, 1979 Donald ]~. ~.~ay 5,349 East 43 Avenue knohoraqe, Alaska 99504 Subject: Lot 1 Lauritz Subdivision Approval for your zndmvzdual ~ewmr and wa%er fac~lmtem,~ can not be granted unu~ltthe follo%,~inq ig~s have been (1) The water analysis report be d~liv~red to ~his office fro~% Ch~ Lab, 5633 B Str~ot, for our r~view. (2) ,.,xpo~;e. the v~(~ll for our inspection to determine proper construction, alae to insure the n%inim't~,l, distance requirements are.. met b~tween your well an~i sewo~r (3) la four(4) inoh cast iron oleanout needs to be in the se, pti(,~ tank and/or ieac][Ang area° [{lea~e notify this department for a re--insp~ction when 'tile noted.descrepancies have been cor~e,~te.,,'i. If there are any further questions~ [31ease con,act this of,_mce at 26~..-47200 Sinc~r~ly, l~)ber't c. Pratt, R.S. Associate opecial~.s., Peoples Bank ~%nd ~i'rust [4ortgage I,o~n D~t>artr~%ent Pouch 7-,-007 99510 99!301 September 12, 1979 Donald May 5949 East 43 Avenue 'Anchorage, Alaska 99504 Subject: Lot 1 Lauritz Subdivision Dear Mr. May: This office received a request for approval of indivdual sewer and water facilities. The request was submitted as a three(3) bedroom single family dwelling. After talking to you and the bank, I have been informed that the residence on the subject property is a duplex. Therefore, before we may send an approval to %he bank the following will need to be completed: (1 Relocate your sewer system so that the leaching area is 120 feet fromyour well and the septic tank 80 feet from your well. (2 (3 Prior to any construction, obtain a soils 'test and submit it to this office so that a permit may be issued. Raise the well casing twelve(12) inches above ground level. If there are any further questions, please contact this office at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/ljw cc: Peoples Bank and Trust Pouch 7-007 99510