LAVANDA LT 1
Onsite File Lavanda Lot 1 #051 - 191 - 42 On -Site Water and/or Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151263 Tax Code Number: 05119142000 Work Type: SepticTank Upgrade Permit Effective Dates: August 14, 2015 to August 13, 2016 Design Engineer: NORTH RIM ENGINEERING Subdivision: LAVANDA Site Legal Address: LAVANDA LT 1 G:1159 Owner/Address: GARNER MICHAEL D & THERESA M PO BOX 671013 CHUGIAKAK 995671013 Site Mailing Address: 23001 SUMAC DR, Chugiak This permit is for the construction of: N Disposal Field Y Septic Tank N Holding Tank N Privy All construction must be in accordance with: Lot Size in Sq Ft: 45623 Total Bedrooms: 3 N Private Well N Water Storage 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: cl// U y Date: MUNICIPALITY OF Community Development Department�" Development Services Division On -Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWERIWELL PERMIT APPLICATION Parcel I.D. (3 51 -Z g 4— 4t/ Z Property owner(s) C-14 R416r"2 Day phone 2�3-16JOZ Mailing address 23Qo1 S0,44--tC 'bR Site address $4w F Legal description (Sub'd., Block & Lot) _ ke!6 F AMA 407— Legal O% Legal description (Township, Range & Section) Lot Size q 5623 5q. Ft. APPLICATION IS FOR: (0 all that apply) Absorption Field ❑ Septic Tank Single Family (SF) Pilo Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms 3 APPLICATION IS AN: TYPE OF DWELLING: Initial ❑ Single Family (SF) Pilo ADU) Upgrade(w1wo Duplex (D) ❑ Renewal ❑ Multiple Dwellings ❑ (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. Permit/Rush Fees: tP 1 Date of Payment: % J 3J 15 CA16- Receipt Number: a4215 Permit No. 05e1512103 Permit App_&1.12.doc Waiver Fees: Date of Payment: Receipt Number: Waiver No. Tk IZM ENGINEERING MEMO Date: 8/1/15 To: MOA On -Site Services Subject: Lavanda S/D, Lot 1 Septic Tank Failure Steve Eng, PE, PH (907) 694-7028 tel northrimeng@aol.com Number of Pages: 4 The subject septic tank has failed, causing backup in the tank, close to surface of cleanouts. Please expedite a permit so the tank can be replaced. The tank baffles appear broken along with general tank failure. Please review as soon as possible. If there is need for additional information or clarification please give me a call. Thanks -Steve �CRTHI I� M ENGINEERING SPECIFICATIONS & DESIGN GUIDELINES Lavanda S/D, Lot 1 Wastewater System Sizing: This is an existing 3 -bedroom, single family home. Most of the neighboring lots are developed. The current septic tank has failed- the Trench is still useable. These lots are large and are served by private water wells. No adverse impacts are expected from tank replacement. The easement is depicted on the lot. The septic tank is almost flowing above ground through standpipes- recommend expediting. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. • New 2- compartment, 1000 gallon septic tank. Watertight couplings on inlet & outlet. • 5' minimum between the tank and bed. 10' to property lines. 4' of cover or insulation is required for tank; an equivalent of I" insulation for 1' foot soil cover. Minimum of 2' soil with insulation. • Tank & solid pipe must be set on well compacted, stable soil. • 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. • All cleanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2% slope. • Septic Tank to be pumped every two years or when required. • Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) DESIGN NOTES: 1. Existing Trench Remains In Place. 2. Sewer Service Line minimum 2% slope. 3. Replace Septic Tank/Decommission Old Tank Per UPC. 4. Lots Served by Private Water Wells. 5. No Conflicts Within 200'. ---_Well Over 100' NOR THRI M ENGINEERING PO Box 770724 Eagle River, Alaska 99577 907.694.7028 10' Utility Easement Well Over 1 10% Slope/ New 1000 Gallon Septic Tank w/DC❑'s Decommission ❑(cl Septic Tank ER UPC 10% Slope/ IV) A/A/7-A/n1 ,jr �L 5 Existing Trench 10% Slope/ Flat/ 3 Bdrm Terrain RI x1sting dh, qy Flat Terr Sumac Drive ff ;�.OF A. %14 LAVANDA S/D 49UL LOT 1 WASTEWATER DESIGN REPLACE SEPTIC TANK 0<0 0F/nORG Well Over 100' 1" = 40' PLAN LAYOUT /14/15 12 of 3 S u i L L H di Y L d F- u U +, 0- a, v 3 +' N as 0 0 d N U 07 L N 0 o_ O O c C3 S U L N L F- 0 O F- O H N i Ln _j L 0 i-' d U > U oj L� LJ O1 U u C5 x C5 X 2:w N Y N O d L U q > O L N O Ol U d 5 0 0 l7 O U S o w0 d L, o uw o L L V O �¢� O H N i Ln _j L 0 i-' d U > U oj L� LJ O1 U u C5 x C5 X 2:w n M U q 4 E a n W 0 m rrO ZZ 02 u U L N N D1 d > d O U S U U L O od w 0 O U u d Q n T D LA N iN L -U LA Z � N a £ U L �1. 4, O £ d 0-E LU d �0.0 Q OUn D_ L NGiU Q1S £ OCLU J 'm L V0 Caj O N N (/1 i £ J O 40 0 p O,b 'a H.6 as L) aU Lq0 OJY = j+' U O L O W O +' d V1 i N -C 1— N U E N O Z N H N W U� vj H O i Q N i 5£ z ad L 3+> 0 0-U w m3 OJ 0�vi0vi3i¢Wq W �Z w p N (h V ho �O I -z n M q 4 O o a n W 0 x rrO ZZ 02 m Z LLJ Oie g IS u w Q Q ; Z 'LIn Q Q ti J J 'm Im W J IH LL ED z 0� w Z W �Z U z Q Q ' J W U D� H a_ z W Q n q O o a n W 0 x N ZZ 02 m Z LLJ Oie g Municipality of Anchorage Page __Z_ of 3 . DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 a Anchorage, Alaska 99519-6650 ® Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: X970/2.7 PID Number:— Name: Daisy J. Dolan Wastewater System: ew ❑ Upgrade s Address: P.O. sox 670495 Chugiak, Ax ABSORPTION FIELD Phone:688-1'236 No. of Bedrooms: Three 3 V,, Deep Trench Shallow Trench ❑ Bed ❑ Mound ❑ Other LEGAL DESCRIPTION Soil Rating: �i �_� GPD/Sq. Ft. Total Depth from original grade: Lot:Block: Subdivie��llor�%% , LaV'Dri Depth to pipe bottom from original grade: Gravel depth beneath pipe ,% a ✓G, 7-1 .0 Ft. Ft. Township: 1 Range: Section: Fill added above original grade: Gravel length: 5113 MG5ax, 2, © Ft. Ft. WELL: New ❑ Upgrade Gravel width: Number=11nes:tanceb/gMeenlines: Ft. //a" Ft. Classification:/ (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material/`] j'M —0 3031 fi r /Z t V4-rc 160 Ft. VT Ft. 5-90 so. Ft. Driller: ��,'� SOLL) VA/J DateDrlled: G 97 Static Water Level: /17 Ft. Installer. /hit's/K Ga�7iRgcr/Ms vim, Date'nstalled: 5 o i4 Z_ Yield:Pump Set at: Casing Height Above Ground: 9 TANK 10 GPM Ft. Z Ft. SEPARATION DISTANCES Septic ❑ Holding ❑ S.T.E.P. To Septic Absorption Lift Holding ovate Manufacturer. Capacity in gallons: oaQ From Tank Field Station Tank Sewer Lines Well, /D Z / >��,1' /�// /✓ ISO' male '91: Number of Compartments: wale a > io4' >/op' N/�- iv/,p- >�rao' LIFT STATION Lot7 aJ r > (� �' N1 N/ y 4,5Size In gallons: Manufacturer: Line Foundation �C� r .fy t N/- N�yQ Pump on" level at: "P level at: High water alarm at: Curtain odel Electrical Inspections performed by: Drain s Remarks: /�.y�`ir 1�ncNf s �s BENCH MARK Fo/cna�,/, �t /i, nd Description: W -A ' Assumed Elevation: / / ENGINEER'S SEAL Inspections performed by: Dates: 1 st a 7 / 2nd 1A - I)7L` Department of Health and Human Services applr�Z/a� 411, 429Fsi'Y Ptd ryr� I' .:��� "1'=«.rx ,���/q Reviewed and approved by: Date: �'2 72-013 (Rev. 9/91) MOA 25 Permit No, SW970127 Page 2 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box.196650 O Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Legal Description: e Lot 1 , Lavonda Subdivision PID No.: 05119142 iN NW1 ( vlb 1�A'(Trar1� A siTe: I oo' Yejiuti �p Tt 0.7.1 LEGEM SP1 Septic Pump, Compartment 1 SP2 n n n 2 C Clean Out MT Monitor Tube Sur17Ac,- M v i G4- 10; LEGEM SP1 Septic Pump, Compartment 1 SP2 n n n 2 C Clean Out MT Monitor Tube Sur17Ac,- M v Permit No. 012 27 Page _ 3 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 a Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report I'' o Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650"", SOILS LOG — PERCOLATION TEST PERFORMED FOR: I I G�� ��G DATE PERFORMED j ?J � b �� LEGAL DESCRIPTION: L c�rod�• �LF�LI - Township, Range, Section: �- Ci npr SITE PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMENTS �M 13' " /4 WAS GROUND WATER ENCOUNTERED? —� S IF YES, AT WHAT s L D DEPTH? p NOISOME E Depth to Water Ar Mmitrinp7 It PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER .,( TPT RUN BETWEEN FT AND FT 4J ����• �,fi /$ //tU J��} x/i .� �� S /� //T •ice V��`wl � � e✓G 'd�/� C S . PERFORMED BY / �_ _ If" curl IFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: s �� �r 7 PP NOISOME PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER .,( TPT RUN BETWEEN FT AND FT 4J ����• �,fi /$ //tU J��} x/i .� �� S /� //T •ice V��`wl � � e✓G 'd�/� C S . PERFORMED BY / �_ _ If" curl IFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: s �� �r 7 FROM MMM CONTRACTING PHONE NO. 6881238 Aug. 28 1997 09:38AN P2 r rb by pncco. aua SULLIVAN WATER WELLS P.O, DON 070272, CHUQIAK, AI ASKA 09587 • TELHPHONE 889.2759 OWNER OF LAND IXPl'H OF WELL hEu S'I'ATI(' LI{VIit.C11 WAl'IiR P'I'. �L _ ADDRESS --..... — ..... —_. LEGAL DESCRIIgION�� 1..-...1---41 !x. ""J14— --- DRAW DOWN 1'f. ..,.----....., t�.= GALS. PER 11111 ,,.,.-6a63 DATE-Slfirled �r,. �.. Ended �_�a __._ ,F' PERMIT NUMIIElT`,�-.. _. ,- KIND OF CASING _..J.L.---- KIND Of FORMATION: Front tp'Ft.- --Ft. From�Ft, trt �^�._,—.Pt...,•; •(�� ��AQ.,iI-t�_�`"ti- Frnnt FI. to...,_�._..rt,_.,.,_..��._.._ - �} 1 M From Ft. to_..—_Ft. .... -m. -., From Ft. M� 16 t. W.t1�.�LS..4�.-1� C..T ��tt.::..._.__.Ft. T,'rr�mFt t ; _ —.... _..� From - romFromT.-Ft..to._. From .-Ft. to,_.Ftp_... —. _—_ . -- From F1. lo-�..-.-.FL._..._...r --_. .,.......�.....�- From --Ft, to�..�Ft, Frmtt�---...Ft.10- „..Ft. From From.. Ft. lo—...—F1.-..,--.,--.....—_. .,. -- From--. -Ft. to.. -....Ft.— ... —,•.-- -- From_... -.—fel. to,� . t From to:__ Y111 .........—._., -- Ft. _.--•- From — --. From.—. --.Ft. to__. _—Ft.. _.. w-- ------ From_.._Ft. to_._ Ft. — — —' From From—.....—Ft. to�_.._-.--.Ft.—.. .• .•..--'_ - ..—Ft. From_. . Ft. to--_ --._..... --._..... — ._... -- RECEIVED MISCL. INt'ORMAT16N: 1997 Municipality of Anchorage Dept. Health & Human Services NAM..-- E DRIGLER'S MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970127 DESIGN ENGINEER:ANDERSON ENGINEERING OWNER NAME:DOLAN DAISY J OWNER ADDRESS:P.O. BOX 670495 CHUGIAK, ALASKA 99567 PARCEL ID:05119142 LEGAL DESCRIPTION: LAVANDA LT 1 LOT SIZE: 45623 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: Ici PAGE 1 OF 1 DATE ISSUED: 6/11/97 EXPIRATION DATE: 6/11/98 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: DATE: �/�;7 ISSUED BY : �A �guJ� �" zv--vo-2� ,71 DATE: ��^ CLL- cti m May 25, 1997 Municipality of Anchorage Department of Heath & Human Services 825 °L" Street Anchorage, AK 99502-0650 Subject: Lot 1, Lavanda Subdivision Septic System Design Impacts to ,Adjacent Properties Dear On Site Services Engineer: We hereby apply for a permit to construct a well and an onsite septic - system on Lot 1, Lavanda Subdivision. The attached Site Plan and backup documentation identify the size and location of the new well and septic I ystem to be constructed on the lot. Wells and septic systems adjacent to the property are shown on the Area Map and are not in conflict with the proposed improvements. Testholes performed on the property revealed clean poorly graded sands and gravels to a depth of 4.5': The material below this level is a s i l t i e r gravel with a slower percolation rate. Testholes placed on the _property i n 1987 by David Dayton, P.E. indicated soils with percolation rates of 2.1, 8.7 and 18.7 minutes per inch. Our results varied from 2 to 20 minutes per inch. We are proposing an average absorption rate of .975 gallons per day per square foot based on the results achieved in the area of the proposed absorption trench: Mr. Dayton's results also indicated groundwater at 10' below the surface. We found no groundwater and no accumulation during the monitoring period. We will. use .Mr. Dayton's results, however, and design for groundwater at 10' because:the area has been unusually dry over the past two years and Mr. Dayton's results may be more typical of an average year. The surface of the Lot slopes from southeast to northwest' at grades varying from -1% to 4%. The surface of the ground in the area of the absorption trenches is fairly flat. The lot is of sufficient size so that ` no encroachments will exist between the septic system and any future systems in the area. 'Lot 1, Lavanda Subdivision May 25, 1997 Page Two If the system is constructed as designed the following statements can be made: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2: The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserved, space, either surface or subsurface, on any lots located in the area: 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern w i I I be maintained. Sincerely Michael E. Anderson P.E. + Attachments _ +C�3/J. CEJ It Esy zfY {t0 AOU 1,4M nil.ihi 1C9"'l b '4� wW=—Mododdi miewcopa AREA MAPI' SCALE 1p? = 100' ���• Tei - ..._ -. - _ - _ •�— �_ � e e e �� �� � � � � ••ems ��� � —.� � �.� s LOT 1 LAVANDA SUBDIVISION c � N ACT, TH #2 PROTECTIVE RADIUS --- - -- 3 SDRM. -HOME titin . r• PROPOSED tr;� WELL �;•�: ��a.79 SUMAC DRIVE: l SITE PLAN sus Y SCALE 1" = 40' Sire TH #1 ` 58' LONG X 3' WIDE WITH 4' GRAVEL SEPTIC SYSTEM LOT 1, LAVANDA SUBDIVISION DESIGN FACTORS: Three Bedroom Home Perc. Rate: 20 Min./Inch Application Rate: .6 GPD/SF SYSTEM REQUIREMENTS: Deep Trench System 1,000 Gallon Septic Tank 4' Drainfleld Rock 3 Bedrooms X 150 GPD / .975 GPD/SF = 461.5 SF of Absorption Area 461.5 SF/8 SF/LF = 58 LF Length of Trench Therefore: Construct a Deep Absorption Trench With One Lateral 58' in Length. Distribution Pipe in Trench Placed at 2' Below the Original Ground Surface. Mound Over Trench a Minimum of 1'. 1 uua l". Z L4 it SP/GT '� 4.� W Z MwI114 . y L'o I1 Gb 2-0 M 14. tj Ii P Gtr-cxrlc,E ' '' UizA►a a�ra.fJ 'l A U c , App, R x -r -a' _ �l. Z Gp b fi:- Z X Z-51=71) -+- �.L GPnlFa-r,' X /.5' F'j TYPICAL DEEP TRENCH SECTION (NO SCALE) . 4 FT.fes- NOTE: Grade Area Over Trench to Drain Away. Maintain 4' Vertical Separation From Ground Water. Minimum 3' Cover Over Trench or Direct Bury Insulation. Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 " L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: " ' M M N -Cr ,(/(, o'q DATE PERFOR ��}�/ac�,-.-y s<i'. 1I' „ �iska'F:'t�' LEGAL DESCRIPTION: Lo -r /e LAv A/JDA Township, Range, Section: 170PT— SLOPE - SITE PLAN 1>`7•`E�T1 �G j o L 1 a� 4 6 e 51. 6 7 a ` 8 9- 10- 11 1011 a a 12- 13- 14- 15- 17 2 131495 17 18 19 20 S P/4 -P ��ZS�'F1ot.C� A10, Z. G 14\ gv,Tr-oM o Cr PIDLC WAS GROUND WATER / ENCOUNTERED? A10 S IF YES, AT WHAT L DEPTH? P E Depth Is Weler Ahsr klenitoring7 1 n1 Date:S Zr b7 Reading Date Gross Net Time Time Depth to Water Net Drop 4;:l S 17 /D: 30 a S/4" •�t in: 34 7YL 4-9S /v : ' � „ 4 : 31 Z t • #`S 1D.-1D.-Ij Z #ip +142.0 IN S " MENEM 7 Z t „ IN IN 0 IMMEMIN IMOMMIN IN 1M MENNEN S IF YES, AT WHAT L DEPTH? P E Depth Is Weler Ahsr klenitoring7 1 n1 Date:S Zr b7 Reading Date Gross Net Time Time Depth to Water Net Drop 4;:l S 17 /D: 30 a S/4" •�t in: 34 7YL 4-9S /v : ' � „ 4 : 31 Z t • #`S 1D.-1D.-Ij Z #ip +142.0 /a: -�o S " 5 5' 7 Z t „ N PERCOLATION RATE 1! (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN Z FT AND --A— FT COMMENTS I c 4 Z PER 646 1 rwJVr►i�a r y,.,y�c.-na_ r IN ZI, �— PERFORMED BY: � � j6 A- L 690"" CERTIFY THAT THIS TEST WAS PERIrORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE 72.008 (Rev. 4/85) Q�/ QLD 1 2 3 ;a S P% (;r P A- P 1� . �' �-r-++ot,w AJ.,L 40 „f(ENGINEER'S SEFiLfi ,, U . Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L.” Street, Anchorage, Alaska 99502-0650 .FOILS LOG -- PERCOLATION TEST ; i � af'� . ! 1. Aroivi ti � q�p' 11, 4�' s Vii• 4 8- PERFORMED FOR: DATE PERFORMED: La'r /t 4NQA Township, Range, Section: 9- 9 LEGAL DESCRIPTION: lAV �— SLOPE SITE PLAN Q�/ QLD 1 2 3 ;a S P% (;r P A- P 1� . �' �-r-++ot,w AJ.,L 40 U . 7 . 8- 9- 9 40 M 10 Ca 1 WAS GROUND WATER ENCOUNTERED? 11 ' S • 1A T WHAT L L 12 a .0 P ,1 E 13 Pp v� UriG S ZS q7 - , O , 15 16 17 d- of NO S Reading Dat® Grow- Net Depth to Net Time Time Water Drop #3 + t.d 11 "f t3 � (.yi" tkL 1z: 3.r 18 19 72-008 (Rev. 4/85) IF YES, A DEPTH? Depth to Water Mit 20 -� I n PERCOLATION RATE ZOO (minutes/inch) PERC HOLE DIAMETER ILII TEST RUN BETWEEN —E— FT AND 6 FT COMMENTS 1S7y+p(,e 7'12C'S0RK-Gb 72/02 i -D 7'657-, PERFORMED BY: �• �aRA � I E'RTIFY THAT THIS FST WAS PERFORMER IN ACCORDANCE WITH ALL STATE AND -MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ----- 72-008 ZL J35" 1316" �.�__.._ ..••w ti.�x.�xftw4vk Selma IOV.".4 ILA -AV A L 1 �� • o I �+ FI I3 ;� -r[J � 4 - t fi -f +)finHFdY �� r R'9f ��)TI. 1• Q9, acle4 .'r 0 �gi9Aet i RJ fl� S �T + .. .� � .. _ F .,a..��...y-i:.�se+-a• Maslow � ,. T+44M1•/ _�N��i 1+43�t� I It!• 4 1t _+ �1 h fd..Rtsrv';41� ; � - _ '� ��4 �•'.,I l z - k'Y • ,,tom _ _ , A ` ,tSiltor � ! -,_ � _.__- .•...�. .x - «. P ...-�_..Fyan�h..w��wi�w.�M•-slwFs�s+'Nwi+rzfW011t�a'ub Y!`GNIVN.n�.ixw x.�,..r.:�•.x ni ..� �-. .. _. s..-.. x.-:... -. ... s i h..'W I �ip+�r��'' „li.h', �`. . �,`!�•''�`"`,..- �_.,. . - '��'it. �,;�k '�'t���+; iY+ !�'tiiWlfF�l�:11�1 E w� W haw ; I W"zF4r�a�* fr�4, '..a.116 �P w5Yi'; .if'ie•':./I:r.t4f.a�i�:-1�-.N ti :�E 6. Rx�tY 3:'Ji l-!i§`�r�t� �#rti ,.r.����wxd..M.>«.�.e�. w:�:n��ri3n+�'IMad1-. �! 1i , 1 A&VWxmftwl !i MY too ~&A" O&Vowv t v I ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 1, LAVANDA SUBDIVISION GENERAL: The scope of this project includes furnishing and installing a new 1,000 gallon septic tank. Work also includes the construction of a new deep absorption trench a total of 58' in length with 4' of drainfield rock beneath the distribution piping. A minimum of 3' of cover or 2' of cover and 2" of direct bury insulation is required over the distribution piping. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining a I I underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,000 gallon septic tank must be procured from an approved source and installed at the location shown on the Site Plan. Lot 1, Lavanda Subdivision May 25, 1997 Page Two 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Lot 1, Lavanda Subdivision May 25, 1997 Page Three 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.I:. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). Lot 1, Lavanda Subdivision May 25, 1997 Page Four 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: A minimum of two inspections are required by Municipal Ordinance. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On-Site Systems Approval Parcel I.D. 051-191-42 Expiration Date: i I 1. GENERAL INFORMATION Complete legal description Lavanda Lot 1 Location (site address) 23001 Sumac Dr Chugiak AK 99567 Current property owner(s) Michael & Theresa Garner Day phone 907.223.1602 Mailing address PO Box 671013 Chugiak AK 99567 Real estate agent Matt Baxter Day phone 907.227.5412 2. TYPE OF DWELLING: E Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well n Private Septic x Water Storage Holding Tank Community Well n Community Public Water System n Public Sewer I I Waiver request for: Distance: Received by: Date: COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 55 t) Waiver Fee $ Date of Payment q/3119 Date of Payment Receipt Number d 404073b /i' • Receipt Number COSA# - C 111109 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On-Site staff may visit the site to verify the information submitted. Name of Firm Eklutna Engineering, LLC Phone 907.355.9820 Address 19162 Mountain Road Chugiak Engineer's Printed Name Curtis Townsend, PE Date April 2, 2019 6. DSD SIGNATURE *' 49 M *+,, System #1 Approved for 3 bedrooms ••t •••••..... System #2 Approved for bedrooms �^c•.°at° 41 2 VI ir�. CE 1904 Disapproved �� F4PROFESSO\'..` Conditional approval for bedrooms, with the following stipulations: ON-SITE G. WATER AND m WASTEWATER PROGKAM S ' .SFROC�S By: ' =/ / Original Certificate Date: T // The Municipality of Anchorage Development Services Division(DSD)issues Certificates of On-Site Systems Approval(COSA)based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA Checklist Legal Description: Lavanda Lot 1 Parcel ID: 051-191-42 If more than 1 septic system on lot: COSA Checklist# of Structure served by this system A. WELL DATA • Well log is filed with Onsite(or attached) Well production at time of test 6.5 gpm Date drilled June 1997 Water storage tank volume 0 gallons Total depth 180 ft Well disinfected for coliform test? ❑ Yes ❑■ No Cased to 25 ft Coliform bacteria is Negative ❑■ Sanitary seal is functioning correctly Nitrate 1.58 mg/L [' Nitrate less than MRL (ND) ❑■ Wires are properly protected Arsenic ug/L ❑i Arsenic less than MRL(ND) Casing height(above ground) 28 in. Collected by Curtis Townsend, PE Date of flow test for COSA 3/27/19 Date of Sample 3/27/19 Static water level at beginning of test 94 ft. Comments large landscaping rocks have been placed to protect well head, see photos B. TANK DATA C. LIFT STATION Age of tank(s) 4 years ❑ Required maintenance completed Tank type/material steel Age of lift station years Measured operating fluid level in septic tank 50" Lift station material • Standpipes/foundation cleanout per record drawing Comments: Date of pumping Aug 2018 D. ABSORPTION FIELD DATA Which system tested (date installed) Jun 1997 Adequacy test date 3/27/19 ❑I■ ALL standpipes present per record drawing Results Q Pass For 3 bedrooms Total measured depth from grade 6 ft(max) Fluid depth prior to test 3 in Measured depth to pipe invert from grade 2 ft(min) Water added 450 gal ❑ N/A—pressurized field New depth 17 in ❑■ Monitor tubes go to bottom of effective. If not, state Elapsed time 78 min depth into effective ❑■ Code-required soil cover over field Final fluid depth 14 in CI System presoaked Absorption rate 450 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment(past 12 months) no date of test) If yes, enter date Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot> 100' Community Sewer Manhole/Cleanout> 100' ID Yes if No ft ❑✓ Yes if No ft Neighboring Tank> 100' E✓ Yes if No ft Private Sewer/Septic Line >25'E✓ Yes if No ft Absorption Field on Lot> 100' ❑✓ Yes if No ft Holding Tank> 100' ['Yes if No ft Neighboring Absorption Fields> 100' Animal Containment> 50' ❑✓ Yes if No ft ❑✓ Yes if No ft Manure/Animal Excreta Storage> 100' Community Sewer Main> 75' E✓ Yes if No ft ❑✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations> 10' ❑✓ Yes if No ft Surface Water> 100' ['Yes if No ft Property Line >5' ❑✓ Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' Q✓ Yes if No ft Private Wells> 100' ✓❑ Yes if No ft Water Main > 10' ✓❑ Yes if No ft Community Wells>200' ✓� Yes if No ft Water Service Line> 10' ✓�Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ✓Q Yes if No ft If absorption field is under driveway comment below Property Line > 10' p✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells> 100' E✓ Yes if No ft Water Service Line> 10' Q✓ Yes if No ft Community Wells>200' 1 Yes if No ft Surface Water> 100' El Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review lg'�P ••• � �:v of Municipal records that the above systems are in conformance with it:49m. / ..*9, MOA COSA guidelines in effect on this date. 0• 1(QGOE' A'S 03.04 ... ILY ••Date 4111/ .�, Lif to. . )4.No CE 1........��';/ `li6:9oROFESS.100:4 i\\\\NZ�". COSA Checklist yellow sheet NOTES: I LOT 2 1. 0 RECORD DIMENSIONS PER PLAT 88-116. LOT 1 2. THIS SURVEY DOES NOT ,, (N 89'2151 E) (167.45') CONSTITUTE A BOUNDARY a,—'-- sing 10' UTILITY EASEMENT JSURVEY AND IS SUBJECT TO ANY INACCURACIES THAT A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD LA VANDA ANY DATA SHOWN BE SUBDIVISION USED TO ESTABLISH ANY PLAT 88-116 FENCE, STRUCTURE OR ANY OTHER LOT 1 IMPROVEMENTS. 3. ALL VISIBLE ABOVE GROUND FEATURES OF THE 7' 7-0 EXISTING SEPTIC SYSTEMrn -4- WERE LOCATED AT THE o N N TIME OF SURVEY AND ARE N SHOWN HEREON. ._.- 12' X 24' SHOP la, N L`' 6.2' x 6.8' 1 p o CHICKEN SKYLINE VIEW — CICK rCP ' 11' X 12' co SUBDI VISION Zin • HOUSE PLAT 69-41 ARE RING LOT 6 DECK LEGEND IJ 2-STORY ' 40.0'± III li FRAME i - GUY WIRE 42.0 �, N HOUSE L J POWER POLE !N Co r--L. 42.0'' C. `� 85.5'± TELEPHONE PEDESTAL I 1 . ASPHALT BLOCK 1-i DRIVEWAY ---— RETAINING • SEPTIC VENT `) N WALL Fl) WELL I. 1 OVERHEAD UTILITY (S 89'55'34""E) \------/ (168.79') w p_ 0 SUMAC DRIVE .6 ASBUILT - NO CORNERS SET THIS DATE in I HEREBY CERTIFY THAT I HAVE PERFORMED rr A SURVEY OF A o y�.��%\XX\ 41 �l LOT 1, LAVANDA SUBDIVISION, PLAT NO. Q ..........4. ,9 ,� 88-116, ANCHORAGE RECORDING DISTRICT, 0 ��P.• •. -4� ALASKA, % ,49TH *�� * AND THAT THE IMPROVEMENTS AS DEPICTED � �� HEREON EXIST AS SHOWN IN RELATION TO o NORTH % THE PROPERTY LINES. EASEMENTS OF ,v�,/. , , i RECORD OTHER THAN THOSE SHOWN ON RECORDED PLAT No. 88-116 ARE NOT Dayna M.Rumfell / r F� • ND 13 22 ' c,�� SHOWN HEREON UNLESS OTHERWISE NOTED. H N D E R �� p;•,• .. DATE: 4/10/2019 FB: 2018112019 SURVEY & MAPPING ��,�fE �;ONP.1 ` GRID: NW 1159 DRAWN: DMR 2890 S. BARNYARD CIR., WASILLA, AK 99654 \����`1 DAYNA RUMFELT (907)301-5177 SCALE: 1" = 50' FILE: 19-006AB MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # 05119142 HAA # A' lag -In I--I(oq 1. GENERAL INFORMATION Complete legal description Lot 1, Lavanda Subdivision Location (site address or directions) Sumac Drive Property owner Daisy J. Dolan Day phone 688-1236 Mailing address P.O. Box 670495 Chugiak AK 99567 Lending agency — Day phone Mailing address— Agent _ Address Day phone Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual well XX Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site XX Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Font MOA #21 a STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Anderson Engineering Phone 563-7155 Address P.O. Box 240773 Anchorage, Ax 99524 Engineer's signature Date 10/3/97 6. DHHS SIGNATURE yi Approved for bedrooms. Disapproved. Conditional approval for Additional Comments M U ITIr bedrooms, with the following stipulations: Date c 9� The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) Back MOA x21 ^r bedrooms, with the following stipulations: Date c 9� The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) Back MOA x21 Municipality of Anchorage / DEPARTMENT OF HEALTH & HUMAN SERVICES R E C e I t 1 Environmental Services Division l� Y 825 L Street, Room 502 • Anchorage, Alaska 99501 • (907) 3430t7f4 3 1997 Health Authority Approval Checklist Municipality of Anchorage Dept. Health & Human Services Legal Description: Lot 1, Lavanda Subdivision Parcel I.D.: 0511 91 42 A. WELL DATA Well type Private If A, B, or C, attach ADEC letter. ADEC water system number Log present(Y/N) Total depth Sanitary seal (Y/N) Date of test Static water level Well production Date completed Cased to 25 _ 5' RearaolOasing height (above ground) 2' FROM WELL LOG WATER SAMPLE RESULTS: Coliform Date of sample: B. SEPTIC/HOLDING TANK DATA 117' Wires properly protected (Y/N) Y AT INSPECTION Nitrate 3.91 mq/r Other bacteria Collected by: Date installed h /'10 �()Z Tank size 1 non_ Number of Compartments 2 _ Cleanouts (Y/N)_Y Foundation cleanout (Y/N) Y Depression (Y/N) _N High water alarm (Y/N) N Date of Pumping New Pumper construct i no C. ABSORPTION FIELD DATA Date installed 7/1 /97 Soil rating (g.p.d./ft2 or ft2/bdrm) 1 -2 _ System type w; rie Tr Pen ch Length 58' Width 5' Gravel thickness below pipe __Total depth R' Effective absorption area 5 s SF Monitoring Tube present (Y/N)Y_ Depression over field (Y/N) N Date of adequacy test New Const. Results (Pass/Fail) _ Pass For _ -3 bedrooms Fluid depth in absorption field before test (in.); Immediately after_ gal. water added (in.): Fluid depth (ins) Minutes later: Absorption rate = _ g.p.( Peroxide treatment (past 12 months) (Y/N) _ If yes, give date _ 72-026 (Rev. 3/96)` D. LIFT STATION - None on Lot Date installed Manhole/Access (Y/N) High water alarm level at* Cycles tested E. SEPARATION DISTANCES Size in gallons "Pump on" level at* *Datum SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot Public sewer main Sewer /septic service line On adjacent lots On adjacent lots "Pump off" level at* Public sewer manhole/cleanout Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation Property line Miles Absorption field >51 Water main/service line >20' Surface water/drainage > 1 00' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line �, I0 Building foundation > 1 0' Water main/service line >20' Surface water >100' Driveway, parking/vehicle storage area >50 ' Curtain drain None on Lot Wells on adjacent lots >100' F. ENGINEER'S CERTIFICATION l certify that I have determined thru field inspections and review of Municipal records that the above`systems are in conformance with NMDA HAA guidelines in effect on this date. Signature G' fnj Engineer's Name Michael F- Anr3Prson , p _ F, Date 10/3/97 n • ♦:rI1•' HAA Fee $ ,)c7y) Int Waiver Fee $ Date of Payment \l)— `Z. -I)-1 2 l Date of Payment Receipt Number Receipt Number 72-026 (Rev. 3/96)*