HomeMy WebLinkAboutLAKE HILL ACRES #2 LT 13 ~.41n~.c~pa~.~ ~y P.O. [ '( 196650 ANCHORAGE, ALASKA 99519-6650 Of (907) 264-4111 Anchorage MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES January 9, 1987 S & S Engineering SRB 196X Eagle River, Alaska 99577 Subject: Lot 13 Lake Hill Acres Subdivision ~2 On-site Sewer Permit ~860373 Upgrade Alan Dubin Property A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1986. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site sewer system the original as-built inspection report (three part form) must be sent to this office for review and approval, and for documentation. If there are any further questions, please call this office at 264-4744. R.W. Robinson Program Manager On-site Services RWR/ljw enc: copy of permit IiE[-~[;::'IJE l:i'. I \..~!!!!11::( ~, ~:::il'::.' 6 9 Zl-'"" 2 9 '? 9 Re: [VIUNIC, .;LITY OF ANCHORAGE MEMORANDUM Date 91-015 [Rew 1/81) Wastewater Disposal Permit for Lot 13 Lake Hill Acres Subdivision Terms and Conditions of Permit: This permit shall be considered an operating permit for an innovative single family household wastewater permit. This initial "evaluation phase" permit is valid for one year and is subject to the testing schedules and stipulations contained in the attached on-site sewer application. At the end of this one year testing period (a shorter period may be allowed upon the discretion of the department) the performance of the system will be evaluated. If the department finds that the system has operated substantially in conformance with the standards outlined in the permit, a new or "extended phase" operating permit will be issued by this department. The terms of this extended phase operating permit will, under most circumstances, prescribe a testing and maintenance schedule that is less rigorous than prescribed in the evaluation phase. The terms of the extended phase permit will be established by this department at a future date. The following conditions pertain to the initial "evaluation phase" operating permit: The effluent testing schedules and procedures described in the letter dated August 5, 1986 and signed by Thomas S. Graham shall be adhered to (see letter attached). The treatment plant shall be converted to a holding tank if in the opinion of this department, the t.esting goals described in the aforementioned letter are not met. If the treatment plant fails to meet the conditions of the permit during the experimental phase (one year or less) the cost of converting the system to a holding tank shall be covered by a $1,000.00 bond deposited in an interest bearing account in the First Interstate Bank, O'Malley Branch. The old well located southwest of the house shall be properly abandoned in accordance with procedures described in AMC 15.55.060, Water Well Standards. A permanent shallow groundwater monitoring well shall be installed approximately 15 feet to the east of the disposal field. This monitoring well shall extend to a minimum depth of 8 feet and be constructed in accordance with standard specifications. The minimum diameter of the slotted monitor tube shall be 2". The tube should be capped and provisions to prevent surface water infiltration into the well should be made. 5o The separation distance between the base of the absorption bed and the measured water table shall be a minimum of two feet. Suitable fill material must be imported if two feet of acceptabl~ soil above the water table does not exist at the site. This fill material must meet specifications outlined in AMC 15.65.060. The 100 foot separation distances required between septic system component and wells and surface waters have been waived. This waiver 'Lot 13 Lake Hill Acres Subdivision Terms and Conditions of Permit Page Two is valid only as long as the conditions of this operating permit and subsequent operating permits have been met to the satisfaction of this department. These distances has been waived as described below: Well to Rid-Waste tank: 70 feet Well to absorption field: 50 feet Mirror Lake to absorption field: Mirror Lake to Rid-Waste tank: 65 feet 95 feet Stephen S. Morris Civil Engineer On-site Serivces permit outlined above. ~'~I ag~r~°~f°ll°w th~°~diti°ns °f ihe D a/,/t~//~/jo~ . _ g SCALE Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: 3 4 5 6 7 8 9 Township, Range, Section: l/ShJ ! /Hz S~. SLOPE SITE PLAN 10 11 12 13 14- 15 16 17 18 19 2O WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT DEPTH? ~_..~(t P E Deplh to Water Alter_ ,~ MonitorinD? ~ Date: Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE __ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN .-- FTAND __FT COMMENTS N iN[[ INe_ _ ._... :::~)ORRD:~4Dc:Y~vITH ALL STATE AND MUNICIPAL GUIDELIN:S ,N~ECT ON THIS DATE.D ATE:CERTIFYf/,~'/(~THAT ~-IIS TEST WAS PERFORMED IN SCALE $ & S ENGINEERING SRB 196X SUBJECT: /_.._ C~ ) C~MPUTATION SHEET DATE: SHEET BY CKD / /',.D REFERENCE: Lot 13; Lakehill Acres There is no well log available for the well located on this property, however, field inspection indicates that the well is at least 120 feet deep (pump setting) and it appears that the well casing extends to that depth. The characteristics of this well appear to be similar to those of the well located on Lot 16 (copy of well log attached). S & $ ENGINEERING. SRB 196X EAGLE RIVER, AK 99577 ATA ALASKAN TECHNOLOGICAL APPLICATIONS, INC. 165 East 56th Avneue Anchorage, Alaska 99518 (907) 562-2560 August 5, 1986 Municipality of Anchorage Department of Health and Environmental Protection 825 L Street Anchorage , A1R-~ka 99502-0650 Attention: Mr RobertW. Robinson Dear Mr Robinson: For some time now Mr. Bruce Erickson of ADEC, your department, and yourself have been discussing new discharge staDda~ds for effluent i~to ground water tables, stzrface discharge a~d w~r discharge. EPA guidelines of 30mg/1 Suspended Solids, 30 rog/1 BOD5,' neutral pH, fecal coliform of 20 colonies per 100., plus nitrates of 10 or less along with an accounting of nitrite, Kjedabal nitrogen, ammonia nitrogen, and dissolved oxygen ~e involved in the testing procedures. At your request, the duration of the test and the procedures for testing are outlined below: TESTING ~ All samples will be collected by an independent contractor to all parties. All samples will be tested at a laboratory licensed by the State of Alaska. All tests will be conducted in a manner prescribed by Standard Methods. TESTING GOALS & PARAMETERS Suspended Solids BOD5 pM Fecal coliform Nitrate-N Nitrats-N Kj edahal Nitrogen Amonia Nitrogen. Dissolved Oxygen Phosphrous Levels Temperature 30 rog/1 30 m~/1 6-9 20 colonies/100 ml. 10 or less TESTING FREQUENCY Weekly for the first three months or 12 samples Monthly for the r~maining months of the test duration: 1 year or less. During the testing period the Engineer will do the in field observations of the system. If service is nee~__ed~_, Manufacturer will service s~stem. Copies of both reports will be submitted to both ADEC and ~DA. After the t~st period (lyf) t_he s~mi-annu~! te~ting will probably be done in conjunction with the POINT OF TESTING Outfall of disinfection INSTAIJJtTION PROCEEURES Power off valve installed downstream from e~k Compressor and pu~ on same circuit Compressor to have gauge to shut 'off ~alve for lack of pressure Alarm on separate circuit Alarm to be both vi~al and audio BONDING The amo%~ of $1,000.00 is to be deposited in an /nterest be~a~ing account in the First Interstate Bank, O'M~lley Branch. Tb~ amount of money will convert tb~ system in a hold/rig tank if needed. Interest ~-e~m~ir~ the property of the holder of the TCD. At the conclusion of tb1~ testing prob,-am of system performance within the arithmatic mean of the parameters of the test, ADEC and MOA shall certify this combination of technology in perfo~ for use in surface O~.~harge, direct discharge, and ground water discharge by having met the above criteria, subject to other regulatory requirements. Special Representative TSS/ds ATA ALASKAN TECHNOLOGICAL APPLICATIONS, INC. 165 East 56th Avneue Anchorage, Alaska 99518 (907) 562-2560 September 29, 1956 To Whom it Nay Concern, This letter is to outline the steps and procedures to convert the Rid-Waste Tank to a "Holding Tank" to meet the Municipal regulations. There is a service charge for maintnanee for the Rid-Waste System in operation. The charge for the conversion will be considered a maintnance call which is already paid in advance by the home owner. STEPS: 1. Power is shut off to compressor house. 2. Power line will be disconnected f~m compressor house. 3. The 2" line coming from the pump in the tank will be cut and capped at compressor house. 4. The 2" line going from compressor house to drainfield or discharge will be cut and capped at compressor house. 5. All ether air lines and power cords will then be cut at ground level. 6. The compressor house will then be removed from location. NOTE: The high level alarm will let the home owner know when tank is due for service. Alarm wilt sound approximately 3 days (450 gals.) before holding tank is full. President-ATA 'ATA ALASKAN TECHNOLOGICAL APPLICATIONS, INC. 165 East 56th Avneue Anchorage, Alaska 99518 (907) 562-2560 All Rid-Waste Systems on test in the Nunicipality will be utilizing ultra-violet disinfection. Ultra-violet disinfection is an option for the Rid-Waste System. Municipality of Anchorage MEMORANDUM DATE: TO: FROM: SUBJECT: November 10, 1986 Robby Robinson, Program Manager John Kennedy,~Engineering Technician III Lot 13 Lake Hill Acres At approximately 1:45 p.m., November 11, 1986, an inspection of the subject property was conducted to determine if a health hazard existed. The investigation revealed the presence of what appeared to be a tank of some type located near the southeast portion of the building with a 4" stand-pipe extending about two (2) feet above ground level. The tank was probed and found to contain approximately four (4) feet of water. There was a depression over the tank near the stand-pipe but no visible evidence that the tank was damaged. Further investigation revealed approximately twenty (20) feet of two (2) inches of flex hose coiled at the southeast corner of the building. The hose ran inside the residence and assumed to connect to a dish washer, sink or washing machine. There is no visible sewage overflow onto the ground surface nor is there any smell of sewage odor in the immediate area. Conclusion: In my opinion, the present condition of the subject property's septic system does not constitute a health hazard. JK/do ATA ALASKAN TECHNOLOGICAL APPLICATIONS,INC. 701 West 58th Avenue Anchorage, Alaska 99518 (907) 563-3117 November 5, 1986 Nr. Robert Robinson Department of Health and Environmental Protection Municipality of Anchorage 825 "~°' Street Anchorage, Alaska 99502-0650 Dear Mr. Robinson: Lot #13, Lake Hill Acres on Mirror Lake is a health hazard for the following reasons: 1. 22" Water Table- 2. Broken holding tank ~ 3. Gray water discharge into Mirror Lake. The owner, Mr. Allen Dubin, has purchased a Rid Waste Environmental System and the permit #860373 has been issued at the pen of S&S Engineering. Hr. Dubin has applied for Municipality funding in the amount of about $4,300 for the field upgrade. According to Stan Hufford, MOA Rehab Director, the program requires the certification of this health hazard. Your immediate attention to this matter will enable us to correct this problem as soon as possible. Thank you in advance for your cooperation. Sincerely: THONAS S. GRAHAM Special Representative TaG/dss ] un c p hty Anti, or. ge P.O. B~JX 196650 ANCHORAGE, ALASKA 99519-6650 (907) 264-4111 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES November 13, 1986 Thomas S. Graham Special Representative Alaskan Technological Applications, Inc. 701 West 58th Avenue Anchorage, Alaska 99518 Dear Mr. Graham: Pursuant to the attached Memorandum from Mr. Kennedy to Mr. Robinson, Lot 13, Lake Hill Acres is not a health hazard. The discharge of 'gray water' into Mirror Lake does not constitute a health hazard, but does place the owner into a position of violation of the Municipal Ordinance and'a citation may be issued if this practice does not stop. The high ground water is the qualifying factor for a holding tank. A properly functioning holding tank will not contaminate ground water. Further evidence of a health hazard will have to be revealed to qualify the owner of this lot for Municipal funding under the Failed Septic System Assistance Program. Sincerely, Environmental Quality Manager cc: Allen Dubin January 4, 1978 Michele Delaney Post Office Box 15 Chugiak, Alaska 99567 Subject: Lot a~ Lake Hill Acres Subdivision 92 Pemmit 977805 A permit issued by this department for well and/or sewer system has expired. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal ordinance. If you have drilled the well, a well log should be sent to this department to document the installation date. If there are any further questions, please contact this office at 264-4720. Sincerely, Health and Environmental Protection Sewer and Water Section P'ilt.4.t.P'IL.ml D.L'.:-,iHi'.,iUE k;EtHb~EJi'.,i FI HEI_.t.~ HNL:, PtN¥ I..)N-.-EiJ: i'E '...;:i[:::HI;:lL~iE ::!.klHd [-'i..:hi i-Lib'. H PI-4'.J.',/Ff/'E: HEt....L O1:,:: ~.~12t Ft::E:l- i.-'CIN: Pi PUL~:LIC: HEi:LI_. p~'i:i.t_, l....l_llj::; l--It-.:b, h.'t::~.:.!Li.il.;.'EiL:, HNL:, P'ikJ~::;I Bi:: k'..~::i'f. JI4:NE[) I'U 'fHl~: LIF. t Hi:: kit:JlA.. C;LIrrtF'L.b'.i ]. 0t'-4. i...ilt.-ii::.N i-~'.[~i.::iI..IINi::FIk:N'I"j:; i','ih:l'?' P:IF'F:'I...'~.'. SF'E)_:~[F~(L::P:iT.[~.JNL:; FIN[::, FIV[--i 1 L..HI:~L.i::: TEl :[ Nb;LIN:E: i:'N'.OF'iaiF?. :[ Nt~-,'i PILL.BT 1[ ON. k L::b.P-.' I t k' '?-' tPiH i' :i: i Hr,'I i--FIi"iIL.LFIk'. H:[i'H i'HE' I:,~:E:~.;:!U:[I:e.E.i¥tEN"iS F'C~F-..' ON-'.:~;1TE.: SEHER$ PIN[:) 14[~L1._$ FtS SE't I-;:'CIk:tH t~'?' 'IFIt::: i',ii. JNiC:J:F'PIL. iT'?' O[:' ;.-:': I H.LLL :LN'::;iF'tLL 'Il-IL:: ::;'T'~z,'fF.l"i ]:i",i I::IC:C:(.IN'.DFINC~ 14ITH TiiEJ