HomeMy WebLinkAboutLAKE HILL ACRES #6 BLK A LT 8A,Rick Mysfrom.
Mayor
M micipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6550
343-4744
April 14, 1995
Gene & Joan Agee
PO Box 671411
Chugiak, Alaska
99567
Subject: Lot 8A Block A Lake Hill Acres Subdivision ~6
Permit ~Sw940073, PID ~051-122-60
The subject permit, issued April 13, 1994 by this office for a
single family well and/or on-site wastewater system, has
expired as of April 13, 1995.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. All inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
/~cerely, /~
~ames Cross, P.E. --
~Program Manager
On-site Services
enc: Copy of Permit
cc: Eagle River Engineering Services
PAGE 1 OF 2
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW940073
DESIGN ENGINEER:EAGLE RIVER ENGINEERING SERVICES
OWNER NAME:AGEE GENE & JOAN
OWNER ADDRESS:P.O. BOX 671411
CHUGIAK AK 99567
DATE ISSUED: 4/13/94
EXPIRATION DATE: 4/13/95
PARCEL ID:05112260
LEGAL DESCRIPTION: LAKE HILL ACRES #6 BLK
8A
ALT
LOT SIZE': 73643 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
ENGINEER MUST MONITOR GROUNDWATER THROUGH MAY 15, 1994 AND
CONFIRM AVAILABILITY OF 2 FT. OF UNSATRURATED INSITU
RECEIVING SOIL. THE SAND USED IN THE FILTER LAYER MUST BE A
CLEAN COURSE SAND WITH 4% OR LESS PASSING THE #100 SIEVE
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
AND 2% OR LESS PASSING THE #200 SIEVE. A SIEVE ANALYSIS
OF THE FILTER SAND MUST BE PROVIDED WITH THE AS-BUILT
INSPECITON REPORT.
RECEIVED BY: ~D~ DATE:
ISSUED BY' -]Ot~ -~W~
DATE:
PAGE 2 OF 2
Eagle River Engineering Services
P.O. Box 773294
Eagle River, AK 99577
694-5195 FAX 694-3297
To:
Jim Cross, P.E.
MOA - On-Site Services
Date: May 17, 1994
Re: Lake Hill Acres//6, Lots 3 & 8A, Block A
Message:
As per special provisions of permit//940073, we have monitored the groundwater levels at test
hole //1 through May 15, 1994. Water level measurements are favorable to our design
assumptions and are attached for your file.
If you have any questions, please contact our office at 694-5195.
Sincerely, , .%~..~
Louis Butera, P.E.
cc: Gene Agee
Total number of pages 2 including this cover sheet.
If you have any questions or if you are missing any pages please call us at 694-5195.
C:\WPWIN60\WPDOCS\1994\93-042A.MEM
Lake Hill Acres #6
Lots 3 SA, Block A
GROUNDWATER MONITORING
WEST TEST HOLE (#1)
Date SU {IN) LLBTP {IN) WL (FT}
6/22/93 10
7/20/g3 31 151 10
7/21/93 31 151.5 10
8/23/93 31 164 11
9/3/93 31 167 11
9/23193 31 159 11
9129193 31 160 11
9/30/93 31 161 11
10/7/93 31 158 11
10/14/93 31 159 11
4/28/94 31 163.5 11
5/16/94 31 164 11
Legend:
SU = Stick up of monitor tube above grade
LLBTP = Liquid level below top of pipe
WL = WL Adjusted below ground surface
93-042B.XLS
Louis Butera, P.E.
Registered Civil Engineer
March 3, 1994
John Smith, P.E.
Manager, On-Site Services
Municipality of Anchorage
P.O. Box 196650
Anchorage, AK 99519
RECEIVED
MAR ,3 1994
M~Jni¢ipality o~ Anchorage
Del~t, Health & Human Services
Re: Lake Hill Acres #6, Lots 3 & 8A, Block A
Dear Mr. Smith:
On August 13, 1993 we submitted a plan for a mounded leachfield to be installed in difficult soil
conditions on the above referenced property. The submittal was returned with the requirements
that we monitor test hole #1 through October, that the drain be located 20' distance from the bed
and that the bed profile be dimensioned.
Tiffs work has been accomplished and is attached. We request your re-evaluation of our submittal.
If you have any questions please call our office at 694-5195.
Sincerely,
Louis Butera, P.E.
\1994\93 -042A.LTR
36'
BANNER
CIRCLE
205,49
/
/
MIN,
W
NON-WOVEN FADRIC
O' 0'0' O' O' 0'0' O'
0 0 0 0 0 0 0
BDTTOH OF TRENCH
FABRIC
WRAPPED PIPE, SLOPE
8X TO DRAIN
EXISTING
0 ,-, bO °o
PRESSURE PIPE CLEANDUT
[] - TEST HOLE
· - MONITOR TUBE
o - SEWER CLEANOUT
+ - WELL
I- PROPOSED CUT-OFF DRAIN
EASEMENT
SEPTIC SITE PLAN
LEGAL: LOTS 8A &: E, BLK A, LAKE HILL ACRES #6
OWNER: GENE AGEE
CONTRACTOR: N/A
dOB # 93-0421 DATE: 05/03/941 SCALE 1" = 60'
EAGLE I~IVEI~ ENGINEERING SEI~WCES
A P.O. Box 773294
EAGLE t~/VER, AIC. 99577
(907) 694-5195 FAX: (907) 694-329'7
EAGLE RIVER
ENGINEERING SERVICES
P.O, Box 773294
EAGLE RIVER, AK 99577
694-5195
/ OF
SHEET NO,
CALCULATED BY L ~ DATE ~7(/'-~ g'/-/~ .~
C~E¢~ED ~¥ ~^TE
~" i ..... ~', ~ ...... ~ ........ ~ ~ ~ ......... i ...... ~ ..... i ....... ~""'"i .......
Louis Butera, P.E.
Registered Civil Engineer
August 12, 1993
John Smith, P.E.
Manager, On-Site Services
Municipality of Anchorage
P.O. Box 196650
Anchorage, AK 99519
Re: Lake Hill Acres//6, Lots 3 & 8A, Block A
Narrative
Dear Mr. Smith:
We are proposing to replace the holding tank serving the above referenced facility with a
leachfield that utilizes a lift station and built-up leachfield. The water table has been monitored
at 2' below a natural silty gravel soil and we believe an on-site system would be feasible for this
lot with the proper design precautions.
The proposed septic upgrade will have very limited impact on adjacent properties for the
following reasons:
The area has large lots allowing sufficient room for septic sites where soil is
acceptable. Most homes have holding tank facilities.
Immediate neighboring septic systems are all +30' distance.
Reserve space is adequate, due to absorption capacity and combined lot size.
Seasonal drainage will be channeled away from the leachbed by a shallow cut-off
drain. We feel this is necessary due to the potential for spring run-off entering
the sand bed and flooding the system. The cut-off drain is not to intercept ground
water.
If you have any questions please call our office at 694-5195.
Sincerely,
Louis Butera, P.E.
\1993\93-042A.NAR
SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM
LEGAL: LOT 3 & 8A, BLK A, LAKE HILL ACRES #6
A. GENERAL
1. The septic plan is for a single family residence only.
2. The drawing and or site plan shall be a part of this specification.
3. All materials and workmanship shall meet the Anchorage Department of Health and State
Department of Environmental Conservation requirements.
4. All soil tests are advisory to the design and are to be verified or modified in the field by the
engineer.
5. All excavations and depths are advisory and are to be verified in the field by the contractor to
meet Municipality of Anchorage, Department of Environmental Conservation requirements.
6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any
adjacent multi-family wells.
7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer
approval.
8. It is always recommended that a surveyor locate the nearest lot line position and the location of
any easements.
B. SEPTIC TANK
1. Sewer line is to be re-routed, exiting on the west side of house with 10' separation to water line
maintained.
2. Tank is to be Orenco Systems with lift station and 20 OSI 05-HHF pump wired to code by a
licensed electrician, receipt to be provided to engineer.
C. LEACHFIELD
1. The leachfield is to be located adjacent to TH#1 as shown on the site plan.
2. The total depth of the drainfield excavation is to be approximately 7.5', removing only the topsoil
layer and underlying clay layer to natural gravel soil surface shown as GP soil on attached soil
log. A clean, scarified surface is to be provided at GP level.
3. An imported clean sand fill is to be placed to ground surface without mechanical compaction and
leveled to _+0. I'. Sand source is to be approved by engineer prior to construction.
4. The drainfield gravel to a depth of 1' is placed on sand layer and is to be covered with typar
fabric material.
5. Pressure effluent pipe is to be buried at +4' and covered with 2" burial foam from tank to field
location. 1-1/4" PVC effluent leachpipe is to be installed 2" below top of gravel bed layer and
is to contain 1/8" holes spaced at 1.4' facing up with orifice shields installed. Pipe ends are to
contain cleanouts buried just below ground level with rebar markers.
6. A combination of soil and extruded board insulation with a minimum soil depth of 2' is to be
placed over the leachfield and sloped 3:1 beyond leachfield at edges.
7.A cut-off drain is to be constructed to direct seasonal surface run-off away from the leaehbed area.
8. The area over leachfields is to be finish graded to prevent pending of surface water runoff. The
entire leachfield mound is to have 4" topsoil and seeded.
9. The septic tank and leachfield must not be closer than I00' to any existing private well, 150' to
any Class "C" well, or 200 feet to any community well.
RECOMMENDED LEACHFIELD DIMENSIONS:
GRAVEL ELEVATION = at grade (mounded)
DRA1NFIELD LENGTH = 36'
SOIL RATING= 0.7 GPD/ft2 (filter)
SEPTIC TANK = 1,250 with lift
GRAVEL DEPTH = 1'
DRAINFIELD WIDTH = 18'
BEDROOM CAPACITY = 3
Twenty-four (24) hours notice required for all inspections.
\1993\93-042A.SPC
'JOB Lake Hill Acres ~6
EAGLE RIVER
ENGINEERING SERVICES SHEET NO. OF.
P,O. Box 773294 L.B.
EAGLE RIVER, AK 99577 CALCULATEDBY. DATE
(907) 694'5195 CHECKED BY DATE
SCALE
Lots 3 & 8A, Blk A
08/12/93
! i Bedhbs6rpti°n!area ~ 4~0'i~~ i0.~ ~ 643 ~qua~e ~eetl !' ........ i .......... i ....... i .......... i ....... ! ....... ! i ! ! i
i ;~ ! .......E'engthi i .k..643.i+!18; xi=136! ...... i ......... i ....... ! ...... ~ ...... i ...... i i ~ i- i } ,! ;~'......i .....
.... i ! i i [/81orifice~hoie@51residmilhead~i=!O.'~3gpmi i i ~ I ~;' i i i
i : 28 gPm flow rate i+ 0.43 gpm/hole=:65holes i ~ i ~ ! .......... i 'i
!' i i 90~Li~"!¢'~65i=il.4"¢'i615"hOle!spa6ing6if6eiitefl : ..... i i ! .....
; i ;. ........ i ~ ;' =' : v~, .~ % c~-~3~ .. ~ ' . '
; X1993X93-042A.CAL ;: ~ ~ : ~ ;: ' ~ :' ~' : :
1IPI
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 'L" Street, Anchorage, Alaska gg502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCRIPTION:
1
2
3
4
5
6
7
8
g
(ENGINEER'S SEAl.! : ;i i:
11
12
13
14
15
16
17
18
19
20-
COMMENTS 'TH*I
DATE PERFORMED=
Township, Range, Section:
SLOPE
I III1'
I I1~11
IIIIII
IIItll
llllll
II I1~,1 I
I Illll
SITE PLAN
WAS ~.OUN~ WaTE.
ENCOUNTERED? T~~ I
L
o o -~
E
IF YES, AT WHAT
I
DEPTH?
!
Depth lo Water Alter ~0.0
Moniloring? Date:
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE ~)'43l(~ (minutes/inch) PERC HOLE DIAMETER --
TEST RUN ~ETWEEN ~ FTA.D ~ F~
PERFORMED BY: ~-I~-H/L ~ I ~~¢'~---~ CERTIFY THA1 THIS tEST WAS PERFORMED IN
' .~/;~/
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THiS DATE. DATE: ~ -~
/
Municipality o! Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
(ENGINEER'S SEAL)
PERFORMED FOR:
DATE PERFORMED:
LEGAL DESCRIPTION: L~-~_,~ J-JlJ~/)t~.,J~i~ L.~A~SA
2
3
4
5
6
7
8
9
~o
12
13-
14-
15-
16-
17-
18-
19-
20
Township, Range, Section:
WAS GROUND WATER
ENGOUNTER ED?
SLOPE
[_1
I IIII
I t111
SITE PLAN
COMMENTS Ik/~t^lJ~ Mo~d~LIU$~
PERFORMED BY:
I
IF YES, AT WHAT Ii '
DEPTH7 , '~
Oeplh to Water Aller ,~:go~ I
'7-
Moniloring? ~'~ Dale:
S
L
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE
EST RUN BETWEEN
__ (minutes/inch) PERC HOLE DIAMETER
FT AND FT
CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE;
GREA,,:R ANCHORAGE AREA BORL.
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
DISTANCE ~
FROM WELL / ~ MANUFACTURER ~~ MATERIAL
~ ~-//
INSIDE LENGTH /~ ~ INSIDE WIDTH LIQUID DEPTH
NUMBER OF
COMPARTMENTS
//
LIQUID CAPACITY ~
TILE DRAIN FIELD:
DISTANCE FROM WELL
FOUNDATION
TOTAL LENGTH
NEAREST LOT LINE OF LINES
NUMBER OF LINES
DISTANCE BETWEEN LINES
TRENCH WIDTH__ IN. TOTAL EFFECTIVE
ABSORPTION AREA
DEPTH: TOP OF TILE TO FINISH GRADE
SQ. FT.
LENGTH OF EACH LINE
DEPTH OF FILTER
MATERIAL BENEATH TILE
IN. ABOVE TILE iN,
WELL:
TYPE _
BUILDING
FOUNDATION__
CESSPOOL
APPROVED _
CONSTRUCTION
NEAREST NEAREST
LOT LINE_ SEWER LINE__
OTHER SOURCES
DISAPPROVED
DEPTH
SEPTIC SEEPAGE
TANK_ SYSTEM
REMARKS
DISTANCE FROM:
DISTANCES:
DIAGRAM OF SYSTEM
SEWER LINE DEPTH:
LOT SLOPE:
REMARKS:
GREA .:,R ANCHORAGE AREA BOR JGH
~FfllIRI~A DEPARTMENT OF ENVIRONMENTAL QUALITY
~ff/'Ull fill Il11~)1~/ ~,0 "c" STREET ANCHORAGE, ALASKA 99503
~.~ ~l~ll~lll ~/~1 TELEPHONE ZT~-4S6~
~ AND PER~IT
SEWAGE DISPOSAl. SYSTE~ ~ APPLICATION
FINANCED THROUGH ,O ,g INSTALLED BY ~
SOIL TEST RESULTS ~OT~: THI~ PER~IT
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FIN.AL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
MINIMUIVI OlSTANCI~S, REOOI~N~S
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
G~AVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS RE~ARDING INSTALLATION.
SEEPAGE AREA SIZE
TYPE
DIAGRAM OF SYSTEM
CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. ~/~~ ~ ~b~:
,r-'~ MUNICIPALITY OF ANCHORAGE /~'~
Departm~ . of Health and Environmental P_ !ection
SOILS LOG
PERCOLATION TEST
Performed for ghuck Phillips Date Performed 9,/17/76
Legal Description Lot 8 Blk ~ Addition ~ 6 Iake I-T~U ~r~s
12
14
16
20
orfanics
frozen ~ray bro~,~u silt w/ ice lenses
oerc rate: 350 + ft~ /hdrm
frozen gray brown silty sand w/ some grave/ (sm)
perc rate: 350 + ft% / bdrm
water table
encountered at-13 feet
thawed gray bro~n
perc rate:
silty sandy gravel (gm)
225% ft /bdrm
.~o'~ .... Depth 1~ feet
AV?~C~E PEPC oATE: > 350 ft / bdrm
Date Net Time Depth Net Drop
Percolation Rate minute
{grrtifirh rillin
by
A & L DRILLING COMPANY
BOX 97, EAGLE RIVER, ALASKA 99577 · TELEPHONE694-2588
OWNER OF LAND (:-f'/-/O c,,/4 /Y/~L/( ~ ! ~,~' DEPTH OF WELL
ADDRESS /'~/~o/( K ~¢~tq ~ STATIC LEVEL OF WATER FT. _
/
LEGAL DESCRIPTION Z.' ~ ~/~ Z~/(~ /~/c(3 '~'(?L~' DRAW DOWN FT.
/ "~' /"' 7/:) ~/~ GA~ PER HR / ,~'~v
DATE- Started "'~f f) ~ / ~ Ended ,/ .
PE~IT NUMBER 7~ ~ ~ O KIND OF CASING
KIND OF FORMATION:
From. (~) Ft. to Ft. /~2o':e~-'d~- ~ c~'~/dd"~ From--
From ~t, Et. to ~:> Ft ~>~' ~/~/e~ From
From 5 C':, Ft. to -~ -) Ft C. ~oi~*u / ~0~ ~/~' ~ ~z ~ From
From <~ "> Ft. to. f~,~ Ft ,~u~ ~,~gc~ ~t 5~-' ~ From
From __ Ft. to. Ft. From
From Ft. to. Ft. From
From Ft. to
From Ft. to ~t. From
From Ft. to. Ft. From
From Ft. to Ft. From__
From. Ft. to Ft, From--
From Ft. to Ft. From
From Ft. to Ft. From--
From Ft. to Ft. From
From Ft. to. Ft. From
From Ft. to Ft. From
From Ft. to Ft. From
Ft. to Ft.
Ft. to Ft.
Ft. to Ft.
Ft. to_ Ft
Ft. to Ft
Et. to__Et
Ft. to Et
Ft. to Ft
Ft. to Ft
.Ft. to Ft
Ft. to Ft
Ft. to Ft
Ft. to Ft
Ft. to Ft
Ft. to Ft.
Ft. to Ft.
Ft. to Ft
MISCL. INFORMATION: