Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LAKE RIDGE TERRACE BLK 2 LT 2
rrc cc MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP211420 Work Type: Septic Upgrade Tax Code Number: 05131525000 Site Legal Address: LAKE RIDGE TERRACE BLK 2 LT 2 G:0653 Site Mailing Address: 15106 E LAKE RIDGE DR, DUPL A, Eagle River Owner: BKB LLC Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft ent c n V Department Total Bedrooms: 10/19/2021 10/19/2022 28674 Q Disposal Field Q Septic Tank Holding Tank Privy Private Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption.system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: D 1. The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. 2. Field investigation is to be done to confirm that the proposed primary and reserve fields meet the 6' separation to any existing fields. CO #1: Eliminate DCO between tank 2 and 3. RMC 10/26/21 CO #2: Moved the bed location due to shallow bedrock. DMS 11/3/21 Received By: Date: Issued By: !/t/ Date: 3 ' VVI UH C� P \LTY OF\ H C H 0 RZA GE= Community Development DepartmentPhone: 907-343-7904 UD Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-315-25 Property owner(s) BKB LLC Day phone 242-7777 Mailing address 18540 Upper Mc Crary Road, Eagle River, AK 99577 Site address 15106 E Lake Ridge Dr Legal description (Sub'd., Block & Lot) Lake Ridge Terrace, Block 2 Lot 2 Legal description (Township, Range & Section) Lot Size 28,674 Sq. Ft. Number of Bedrooms 6 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑ (w/wo ADU) Septic Tank ® Upgrade RX ❑X (D) Holding Tank ElRenewal ElDuplex Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Munici pal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Waiver Fees: Date of Payment: cl /30AZ ( Date of Payment: Receipt Number: �� 8 Ll 5 S E) Receipt Number: Permit No. 05 P I Y ZO Waiver No. Permit App_'-'-:. :'-.,:c; .: ?+ _.GE ENGINEERING abs, f November 3, 2021 PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) FORGECIVIL.COM MOA Development Services, On -Site Water & Wastewater Program 4700 Elmore Rd, Anchorage, AK 99507 Subject: Lake Ridge Terrace, Block 32 Lot 2 — E Lake Ridge Dr Septic system change -order design Dear On -Site Services Engineer: Ad Alw low 49 M r Benda in Schiller �� ��c •. CE 12592 �'J'%F •. 11/3/21..•'�G�i We were recently issued a permit for the installation of a new 6 -bedroom septic. system on the subject lot. After prepping the proposed septic area for installation, bedrock was found at a shallower depth than expected, forcing us to relocate the absorption bed. An effort was made to locate the existing cribs and trenches but nothing could be found that matches the Muni records. However, an undocumented, shallow, 30' long absorption trench was located and removed from the new proposed bed location. An old, cast-iron drain pipe was found near the end of the undocumented trench that ran towards the southeast property corner where a utility/power pole is located, but the pipe ended abruptly before reaching the property line. We expect that the existing documented cribs and trenches may have been installed over the property line and removed possibly when the utility pole was installed. We are therefore proposing relocating the bed in the location mentioned above. A minimum of 2' of receiving soils was confirmed over the length of the new bed location. The attached site plan identifies the location of the home as well as the existing well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot is mostly flat with a gradual slope less than 5% toward the northwest. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new bed will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 50' from all wells and surface water, and more than 5' away from the septic tank. The alternate site is located more than 6' away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE LAKE RIDGE TERRACE SUB, BLOCK 2 LOT 2 / CO _.EXISTING WELL \ w/ 109' RADIUS LOT 3 \vo XISTIN NOTE: MAINTAIN AT LEAST 10' FROM /� FOUNDATION w/ TANKS & 5' FROM UNNAMED TR AM PROPERTY LINE w/ TANKS & BED �' - F _ PER MOA APPING \ / j5Q' STFEAM \ _�ti S \ ANION / EXISTING / REMOVED & DISPOSED OF 1530 -GAL PLASTIC SINGLE \ COMPARTME T TANK w/ 20" MAtJWAY �j (1� / � \\ 2C0 •' T&E EA�EM NT \ LOT 92 us \LOT 2 n 1060 -GAL PLASTIC SINGLE zCOMPARTMENT TANK i 1060 -GAL PL�STIC SINGL\ - ` _0O COMPARTMENT \ RECIRCIILATION TAN} THH#1 NS750 AEROCELL�FILTER POD/ w/ INSPECTION PORTS ON EACH SIDE 25' LONG x�0' WIDE�.5' EFFECTIVE SG WELL 7PTH ABSORPTION BED w/ 100' RADIU_\ MANIFOLD AT CENTER / LOT 1A -I tMIRGE ENGINE[EING CDNFI MR ATIOI PERCOLATION ALTERNATE SITE LIMITS OF MOUND NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 50' OF TH PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. 0 50 100 FEET 111=50' } NO TRACE OFTHE EXISTING CRIBS OR TRENCHES WERE FOU " D. AN UNDOCUMENTED SHALLOW TRENCH WAS LOCATED & REMOVED FROM THE PROPOSED BED LOCATION. 2' MINIMUM OF RECEIVING SOILS •WAS CONFIRMED UNDER THE I PROPOSED BED LOCATION. 1r / I LOT I E LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LAKE RIDGE TERRACE SUB, BLOCK 2 LOT 2 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592R EGISTEREDPROFE S S I O N ALENGINEER4" PVC (HOLES DOWN) DRAINFIELD ROCK1' DESIGN FACTORS:SYSTEM REQUIREMENTS: 900 GPD PEAK FLOW PERK RATE: 1.5 MIN/IN APPLICATION RATE: 4.0 GPD/SF MOUND SYSTEM 1530-GAL PLASTIC SINGLE COMPARTMENT TANK, 1060-GAL PLASTIC SINGLE COMPARTMENT TANK, 1060 PLASTIC SINGLE COMPARTMENT RECIRCULATION TANK w/ NS750 AEROCELL FILTER POD BOTTOM OF TRENCH: 1' ABOVE GRADE FLOW LINE ELEVATION: 1' 6" ABOVE GRADE TOP OF TRENCH: 4' ABOVE GRADE 900 GPD / 4.0 GPD/SF = 225 SF BED REQUIRED (250 LF SPECIFIED) October 14, 2021 2' 1' 6"6" 2' 2:1 MOA APPROVED FILTER SAND TYPE 2 OR FILTER SAND 2" OF 40 PSI INSULATION PROVIDE SOIL STABILIZATION FOR MOUND USING JUTE MESH & VEGETATION/SEEDING 3' 4' 3' NOTE: REMOVE ALL PEAT AND ORGANICS UNDER BED Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211420, Deb Wockenfuss, 10/19/21 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) J. MILLETTE DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH?5' 1.5 6 4 5 8/25/21 1 2 3 4 5 6 GP (POORLY GRADED GRAVEL) Professional Engineers Stamp: YES 3' 8/31/21 LAKE RIDGE TERRACE B2 L2 8/25/21 051-315-25 AUDREY MASON 10:001 2 3 4 5 6 0 0 16 / 6 0 16 10:05 10:11 10:19 10:29 10:39 OB & PEAT 4:10 Benjamin Schiller CE 12592R EGISTEREDPROFE S S I O N ALENGINEERSeptember 27, 2021 4:35 5:58 7:17 9:20 9:15 0 0 16 / 6 0 16 0 0 16 / 6 0 16 0 0 16 / 6 0 16 0 0 16 / 6 0 16 0 0 16 / 6 0 16 6 0 16 6 0 16 6 0 16 6 0 16 6 0 16 6 0 16 BEDROCK ROLLS AND VARIES IN DEPTH DEPENDING ON LOCATION. BEDROCK IS BETWEEN 4 & 6 FEET FROM ORIGINAL GRADE. BED- ROC K Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211420, Deb Wockenfuss, 10/19/21 s 9� lz'' K,6 � 6zof -z> Oele a � s C H ASBUII_T I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: AND THAT NO FNCROACHMEN"I�S EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXis*rENCE OF ANY EASEMENTS, COVENANTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD A.NY DATA HEREON BE USED FOR CONSTRUCTION OF FENCE LINES, OR FOR ESTABLISHING BOUND_ 6,RY LINES. A/,5,9 psi 7y w S.EWARD & ASSOCIATES LAND SURVEYING 694 - 082 SCALE Ot- At �y DATE: * 49 GRID ...... ....a r •d Oum- AUsrk Snwnrd L� o 41 .MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this 18 Day of Audrey Mason October of 20 21 , by and between herein the "OWNER." and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewatei, Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as Q. c.,. a n i G S located at (legal description) Lake Ridge Terrace Sub, Block 2 Lot 2 2. Maintenance. Repairs and Alterations. (Owner is required to read, understand and initial each section) 4� Throughout the tern of this Agreement, the Owner shall enter into a service agreement _- with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The ANVWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the ecl uipment's approval for operation in the Municipality. _.1t -shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance. adjustment(s), replacement costs; and 'inspection costs. This includes an annual maintenance fee (typically $400 to $600). (�t'�_ caner atrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. O,,vner acknow.le.daes. that renular maintenance of an AWVdTS reduces the potential L -- failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2019) Pagel of 3 UVJ Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. edges that the fine for failing to maintain and repair an A1VIWTS may be assessed in accordance with AI` -1C 14.60.030. Owner 9-g—re"-'e's to grant the Municipality, reasonable access to test and inspect the AIA7WTS. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. -0,xi7er-agrecs that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. div 0\tiiier,,igrees--to,maintaiii remote monitoring of the AWWTS as required by the AWWTS approval. 3. Tei -in. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer oftitle, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipility, at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions'. nor in any way affect the validity of the Agreement or any pail hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner acid Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void, 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be I brought in the Superior Court for the Third Judicial District of the State of Alaska at Z7 Anchora-e. The laws of the State of Alaska shall govern the riLyhts and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court or competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05,/18/2018) Page 2 of 3 ature) Date: ) ss. THIRD JUDICIAL DISTRICT ) name) The foregoing inpr ent was acknowledged before me this I --day of oed"'S! 20A, by 6LLdAAt %ii2Y1 (rev. 05/1.8/2018) Page 3 of 3 � sHorT '•, NOTARY PUBLIC FOR AL SIC o� ,,�'��S:�o's �' Nly Commission expires.: 5 - ' 1�0'. �OTAR Y ��'� .t -j OF 0,7�A��;;�, MUNICIPALITY' By; (signature) Date: I0 /9 Z 1 (print name) Title: (rev. 05/1.8/2018) Page 3 of 3 GRr"~I~R ANCHORAGE AREA BOROb~ '~ HEALTH DEPARTMENT *~T.O 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM 829 LOCATION SEPTIC TANK: MAILINGADDRESS ~,~', t'~'~ i~)2~ ;'~4tg,..F.4~I/~Z../JI, R~-t©NE G&'~'-~¢~2 LEGAL DESCR PnON DISTANCE FROM WELL~'~2 ~tL~'u)Tll~,l]'J LIQUID CAPACITY /~-~(~ GALLONS. NUMBER OF MATERIAL,kJ'~'/~/~ .~7~ / .~1~110~£.1), COMPARTMENTS LIQUID INSIDE LENGTH ~ INSIDE WIDTH -- DEPTH SEEPAGE SYSTEM: NUMBER OF PITS LINING MATERIA[ NEAREST LOT LINE SEEPAGE PIT: OUTSIDE DIAMETER OR WIDTH ~)C) , LENGTH ~)~0 I . DEPTH DISTANCE FROM WELl /~')C~ j'~c~u)/~/) , BUILDING FOUNDATION TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~b(~ SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL/~20~ //~'~//l/~O , FOUNDATION /~' J~,~i'~/l NEAREST LOT LINE. NUMBER OF LINES ~:-~- DISTANCE BETWEEN LINES -- TRENCH WIDTH ABSORPTION AREA ~ (~ ;~ SQ. FT. LENGTH OF EACH LINE ~/~'~,. ~ % :'~ ~) DEPTH: TOP OF TILE TO FINISH GRADE -~ DEPTH OF FILTER MATERIAL BENEATH TILE TOTAL LENGTH/)/ OF LINES IN. TOTAL EFFECTIVE ~-~'"' IN. ABOVE TILE WELL: LOT LINE DISTANCES: DISTANCE FROM -- WATER TYPE/~?~s¢~. . DEPTH , BUILDING FOUNDATION. SAMPLE NEAREST NEAREST . SEPTIC x SEEPAGE ~ -. OTHER SEWER LINE - TANK ~-~) ~/~) SYSTEM ~/~/~'~..'CESSPOOL , SOURCES DIAGRAM OF SYSTEM . . . ~ - - GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TUDOR ROAD POUCH 6-650 ANCHORAGEi ALASKA 99502 TELEPHONE 279-B686 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT ,NSTALLAT,ON LDCATION INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO SE SERVED FINANCED THROUGH i~L~ ~/1~ / SEEPAGE PIT HER FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK ~J FOUNDATION TO SEEPAGE PIT If;./ SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK , SEEPAGE PiT , DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK SEEPAGE PIT DRAIN FIELD ALSO CONSIDER AREA WELLS. ~> I~ WATER MAIN TO SEPTIC TAN~ , S~EPAGE PIT DRAIN F~ELD g ~- SEPTIC TANK, . ~'' ., SEEPAGE PIT , DRAIN FIELD _, DRAIN FIELD DIAGRAM OF SYSTEM TO RIVER, LAKE, STREAM. . CAS.T~. RON tN~O--AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PI~ FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. HEALTH AUTHORITY OR LICENSED DESIGNER ~ CERTIFY THAT I AM FAMILIAR With THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE '<ATER ANCHORAGE AR}iA BOROUGH HUALTII DEPARTMENT 327 EAGLE STREET ANCHORAGE, ALASKA 99501 CASE ii u pel*formcd For . This Fcrm Dep~.h Feet Soil Characteris:ics -~/~ ~ ' , 2 Block 2 .'.Sub-~Iv-q--si'~n_.L.a.kerid~_Terrace " ' '¥ercolatio~ Test ...... Location Sketch · Reading Da~e G~oss Time Net Time Depth To ~20. Ne~ D~op e:~colal ~ _ 2~oposed instal~ion:~Seepage Pit "~" D~ain Field ~-~ Deoth Of Inlet ~ eptn To Bot.~om Of P~ O~ TP ~OYM;,U~,, ,~ ~"'. . - . ~ ench ~~'c~.,-,~<~ J-Zt~ ~ ~' ~ F... ~ ~ . .,// ~ - ~ .. Da~a Certified By; GRE'-'ER ANCHORAGE AREA BDt' UGH INSTA'LAT,ON LODAT,ON INSTALLATION OF: SEPTIC TANK TYPE ANB Sl~g OF FACILITY TO B~ SERVED ~NANCED THROUGH SOIL TEST RESULTS DEPARTMENT OFENVIRONMENTAL QUALITY ,,,,0 ,,c,, STREET ANC,-,OR*GE, A'-ASK* '"'0' Di;~O;AL ~Y2T:M -~ APPLICATION AND PERMIT SEEPAGE IT % TO be INSTALLED bY ~A ~ ~ ~ NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL iNSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE TYPE SEEPAGE ARea SIZE TYPE DIAGRAM OF SYSTEM MINIMUM DISTANCES, REQUIREI~IENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK , SEEPAGE PIT TO NEAREST LOT LINE. WELL TO SEPTIC TANK DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD. SEEFAGeF,T / ALSO CONSIDER AREA WELLS. SEEPAGE PIT DRAIN FIELD SEPTIC TANK, , SEEPAGE PIT TO RIVER, LAKE, STREAM. ,, DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORA_~j~ArEA BOrOUgh ORDINANCE NO. 28-68 AND THAT THe ABove DESCRIBED SYSTEM IS IN~ACCORDA~E WITH SAID CODE. ~///~ ~ DEPT. OF ENVIRONMENTAL CONSERVATION / / SOUTHCENTRAL REGIONAL OFFICE / 338 DENAL/ STREET / MACKAYBUILDING-ROOMS"rO ANCHORAGE 99501 October 24, 1975 Mr. Rolf Strickland Anchorage Municipality 3330 C Street Anchorage, AK 99503 Subject: Lot 2, Block 2, Lake Ridge Terrace (Gaard) Dear Mr. Strickland: This office has no objection to the use of the old semi public distances with regard to protective radii if the duplex was constructed prior to August 1973 and if the 200 foot requirement will cause undue hardship. Sincerely, Kyle~J. Cherry, ~. Eo Regional Environmental Supervisor ec~ Ronelva Gaard