MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP211420
Work Type: Septic Upgrade
Tax Code Number: 05131525000
Site Legal Address: LAKE RIDGE TERRACE BLK 2 LT 2 G:0653
Site Mailing Address: 15106 E LAKE RIDGE DR, DUPL A, Eagle River
Owner: BKB LLC
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft
ent
c n
V
Department
Total Bedrooms:
10/19/2021
10/19/2022
28674
Q Disposal Field Q Septic Tank Holding Tank Privy Private Well Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption.system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
D
1. The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The
Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit
stamped and signed results with the As -built Inspection Report. If the results require a design change,
construction of the system will stop pending On -Site review and approval.
2. Field investigation is to be done to confirm that the proposed primary and reserve fields meet the 6' separation
to any existing fields.
CO #1: Eliminate DCO between tank 2 and 3. RMC 10/26/21
CO #2: Moved the bed location due to shallow bedrock. DMS 11/3/21
Received By: Date:
Issued By: !/t/ Date: 3 '
VVI UH C� P \LTY OF\ H C H 0 RZA GE=
Community Development DepartmentPhone: 907-343-7904
UD
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 051-315-25
Property owner(s) BKB LLC Day phone 242-7777
Mailing address 18540 Upper Mc Crary Road, Eagle River, AK 99577
Site address 15106 E Lake Ridge Dr
Legal description (Sub'd., Block & Lot) Lake Ridge Terrace, Block 2 Lot 2
Legal description (Township, Range & Section)
Lot Size 28,674 Sq. Ft. Number of Bedrooms 6
APPLICATION IS FOR: APPLICATION IS AN:
TYPE OF DWELLING:
(N all that apply)
Absorption Field
❑X Initial ❑
Single Family (SF) ❑
(w/wo ADU)
Septic Tank
® Upgrade RX
❑X
(D)
Holding Tank
ElRenewal ElDuplex
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Munici
pal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: Waiver Fees:
Date of Payment: cl /30AZ ( Date of Payment:
Receipt Number: �� 8 Ll 5 S E) Receipt Number:
Permit No. 05 P I Y ZO Waiver No.
Permit App_'-'-:. :'-.,:c;
.: ?+ _.GE
ENGINEERING
abs, f
November 3, 2021
PO BOX 240773
ANCHORAGE, AK 99524
522-7773
677-7766 (FAX)
FORGECIVIL.COM
MOA Development Services, On -Site Water & Wastewater Program
4700 Elmore Rd, Anchorage, AK 99507
Subject: Lake Ridge Terrace, Block 32 Lot 2 — E Lake Ridge Dr
Septic system change -order design
Dear On -Site Services Engineer:
Ad
Alw
low
49 M
r Benda in Schiller
�� ��c •. CE 12592
�'J'%F •. 11/3/21..•'�G�i
We were recently issued a permit for the installation of a new 6 -bedroom septic. system on the
subject lot. After prepping the proposed septic area for installation, bedrock was found at a
shallower depth than expected, forcing us to relocate the absorption bed. An effort was made to
locate the existing cribs and trenches but nothing could be found that matches the Muni records.
However, an undocumented, shallow, 30' long absorption trench was located and removed from
the new proposed bed location. An old, cast-iron drain pipe was found near the end of the
undocumented trench that ran towards the southeast property corner where a utility/power pole is
located, but the pipe ended abruptly before reaching the property line. We expect that the existing
documented cribs and trenches may have been installed over the property line and removed
possibly when the utility pole was installed. We are therefore proposing relocating the bed in the
location mentioned above. A minimum of 2' of receiving soils was confirmed over the length of
the new bed location. The attached site plan identifies the location of the home as well as the
existing well, septic location and alternate site. No conflicts exist between this proposed system
and any other well or septic system, whether on this lot or adjacent lots.
The ground surface on the lot is mostly flat with a gradual slope less than 5% toward the northwest.
There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate
site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater
drainage will not impact this septic system. The new bed will be constructed parallel to the slope
as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum
of 50' from all wells and surface water, and more than 5' away from the septic tank. The alternate
site is located more than 6' away.
Please refer to the attached test hole log, plan and profile pages for the septic design. If this design
is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
LAKE RIDGE TERRACE SUB, BLOCK 2 LOT 2 / CO
_.EXISTING WELL \
w/ 109' RADIUS
LOT 3
\vo XISTIN
NOTE: MAINTAIN AT LEAST 10' FROM /�
FOUNDATION w/ TANKS & 5' FROM UNNAMED TR AM
PROPERTY LINE w/ TANKS & BED �' - F
_ PER MOA APPING
\ / j5Q' STFEAM
\ _�ti S \ ANION
/ EXISTING
/ REMOVED &
DISPOSED OF
1530 -GAL PLASTIC SINGLE \
COMPARTME T TANK w/ 20" MAtJWAY
�j (1�
/ � \\ 2C0 •'
T&E EA�EM NT \
LOT 92
us
\LOT 2 n
1060 -GAL PLASTIC SINGLE
zCOMPARTMENT TANK i
1060 -GAL PL�STIC SINGL\ - ` _0O
COMPARTMENT \
RECIRCIILATION TAN} THH#1
NS750 AEROCELL�FILTER POD/ w/
INSPECTION PORTS ON EACH SIDE
25' LONG x�0' WIDE�.5' EFFECTIVE
SG WELL 7PTH ABSORPTION BED
w/ 100' RADIU_\ MANIFOLD AT CENTER
/ LOT 1A
-I tMIRGE
ENGINE[EING
CDNFI MR ATIOI
PERCOLATION
ALTERNATE
SITE
LIMITS OF MOUND
NOTE:
NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 50' OF TH
PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
SYSTEMS.
0 50 100
FEET
111=50'
} NO TRACE OFTHE EXISTING
CRIBS OR TRENCHES WERE
FOU " D. AN UNDOCUMENTED
SHALLOW TRENCH WAS
LOCATED & REMOVED FROM THE
PROPOSED BED LOCATION. 2'
MINIMUM OF RECEIVING SOILS
•WAS CONFIRMED UNDER THE
I PROPOSED BED LOCATION.
1r /
I
LOT
I
E LEGEND
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LAKE RIDGE TERRACE SUB, BLOCK 2 LOT 2
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592R
EGISTEREDPROFE S S I O N ALENGINEER4" PVC (HOLES DOWN)
DRAINFIELD ROCK1'
DESIGN FACTORS:SYSTEM REQUIREMENTS:
900 GPD PEAK FLOW
PERK RATE: 1.5 MIN/IN
APPLICATION RATE: 4.0 GPD/SF
MOUND SYSTEM
1530-GAL PLASTIC SINGLE COMPARTMENT TANK,
1060-GAL PLASTIC SINGLE COMPARTMENT TANK,
1060 PLASTIC SINGLE COMPARTMENT
RECIRCULATION TANK
w/ NS750 AEROCELL FILTER POD
BOTTOM OF TRENCH: 1' ABOVE GRADE
FLOW LINE ELEVATION: 1' 6" ABOVE GRADE
TOP OF TRENCH: 4' ABOVE GRADE
900 GPD / 4.0 GPD/SF = 225 SF BED REQUIRED
(250 LF SPECIFIED)
October 14, 2021
2'
1'
6"6"
2'
2:1
MOA APPROVED
FILTER SAND
TYPE 2 OR
FILTER SAND
2" OF 40 PSI INSULATION
PROVIDE SOIL STABILIZATION FOR MOUND
USING JUTE MESH & VEGETATION/SEEDING
3' 4' 3'
NOTE: REMOVE ALL PEAT AND ORGANICS UNDER BED
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211420, Deb Wockenfuss, 10/19/21
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE:
PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
TECHNICIAN:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DEPTH
(feet)
PROJECT No.:
TEST HOLE 1
SLOPE
SLOPE
SITE PLAN
DATE READING GROSS TIME
(minutes)
NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH)
TEST RUN BETWEEN: FT. and FT.
COMMENTS:
(inches)(inches)
J. MILLETTE
DATE OF MONITORING:
WAS GROUND WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING:
IF YES @ WHAT DEPTH?5'
1.5 6
4 5
8/25/21
1
2
3
4
5
6
GP (POORLY GRADED GRAVEL)
Professional Engineers Stamp:
YES
3'
8/31/21
LAKE RIDGE TERRACE B2 L2
8/25/21
051-315-25
AUDREY MASON
10:001
2
3
4
5
6
0 0
16 / 6 0
16
10:05
10:11
10:19
10:29
10:39
OB & PEAT
4:10
Benjamin Schiller
CE 12592R
EGISTEREDPROFE S S I O N ALENGINEERSeptember 27, 2021
4:35
5:58
7:17
9:20
9:15
0 0
16 / 6 0
16
0 0
16 / 6 0
16
0 0
16 / 6 0
16
0 0
16 / 6 0
16
0 0
16 / 6 0
16
6 0
16
6 0
16
6 0
16
6 0
16
6 0
16
6 0
16
BEDROCK ROLLS AND VARIES IN DEPTH DEPENDING ON LOCATION. BEDROCK IS BETWEEN 4 & 6
FEET FROM ORIGINAL GRADE.
BED-
ROC
K
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211420, Deb Wockenfuss, 10/19/21
s
9�
lz''
K,6 �
6zof
-z> Oele
a
� s
C
H
ASBUII_T
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
FOLLOWING DESCRIBED PROPERTY:
AND THAT NO FNCROACHMEN"I�S EXIST EXCEPT AS
INDICATED. IT IS THE RESPONSIBILITY OF THE
OWNER TO DETERMINE THE EXis*rENCE OF ANY
EASEMENTS, COVENANTS, OR RESTRICTIONS
WHICH DO NOT APPEAR ON THE RECORDED SUBDI-
VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD
A.NY DATA HEREON BE USED FOR CONSTRUCTION
OF FENCE LINES, OR FOR ESTABLISHING BOUND_
6,RY LINES.
A/,5,9 psi 7y
w S.EWARD & ASSOCIATES LAND SURVEYING 694 - 082
SCALE
Ot- At
�y
DATE:
* 49
GRID
...... ....a r •d
Oum- AUsrk Snwnrd L� o
41
.MUNICIPALITY OF ANCHORAGE
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and
entered into as of this 18 Day of
Audrey Mason
October of 20 21 , by and between
herein the "OWNER." and the Municipality of
Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code
(AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this
Agreement agree as follows:
1. Advanced Wastewatei, Treatment Systems. The Municipality grants permission to the
Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS),
described as Q. c.,. a n i G S
located at (legal description)
Lake Ridge Terrace Sub, Block 2 Lot 2
2. Maintenance. Repairs and Alterations.
(Owner is required to read, understand and initial each section)
4� Throughout the tern of this Agreement, the Owner shall enter into a service agreement
_- with an AWWTS service and maintenance provider approved by the Municipality or the
manufacturer's representative. The ANVWTS shall be maintained in a satisfactory
condition capable of performing as designed and producing treated septic effluent in
accordance with the ecl uipment's approval for operation in the Municipality.
_.1t -shall be the responsibility of the Owner during the term of this Agreement to pay for all
repair(s), maintenance. adjustment(s), replacement costs; and 'inspection costs. This
includes an annual maintenance fee (typically $400 to $600).
(�t'�_ caner atrees that only maintenance and repair personnel approved by the Municipality
or the manufacturer's representative will inspect and make any necessary maintenance,
repairs or permitted alterations to the system.
O,,vner acknow.le.daes. that renular maintenance of an AWVdTS reduces the potential
L -- failure of the system, which could include sewage backup and costly repairs or drainfield
replacement.
(rev. 05/18/2019) Pagel of 3
UVJ Owner acknowledges that the Municipality may request records of maintenance and
repairs from the manufacturer's representative or maintenance provider.
edges that the fine for failing to maintain and repair an A1VIWTS may be
assessed in accordance with AI` -1C 14.60.030.
Owner 9-g—re"-'e's to grant the Municipality, reasonable access to test and inspect the
AIA7WTS. The Municipality will give at least 24-hour notice.
Owner agrees that any sale or transfer of title of the property will not occur without a new
Certificate of On -Site Systems Approval.
-0,xi7er-agrecs that the AWWTS installation and maintenance requirements as provided
by the AWWTS vendor/installer and approved by the Municipality are the governing
guidelines for the construction, maintenance and repair of the Owner's AWWTS.
div 0\tiiier,,igrees--to,maintaiii remote monitoring of the AWWTS as required by the
AWWTS approval.
3. Tei -in. The term of this Agreement shall begin on the date of approval by the
Municipality to operate the installed system, or upon transfer oftitle, and shall continue
while the AWWTS is operational or until title is transferred.
4. Nonwaiver. The failure of the Municipility, at any time to enforce a provision of this
Agreement shall in no way constitute a waiver of the provisions'. nor in any way affect
the validity of the Agreement or any pail hereof, or the right of the Municipality
thereafter to enforce every provision hereof.
5. Amendment. This Agreement shall only be amended by authorized representatives of
the Owner acid Municipality. Any attempt to amend this agreement by either an
unauthorized representative or unauthorized means shall be void,
6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be
I
brought in the Superior Court for the Third Judicial District of the State of Alaska at
Z7
Anchora-e. The laws of the State of Alaska shall govern the riLyhts and obligations of the
parties under this Agreement.
7. Severability. Any provisions of this Agreement decreed invalid by a court or competent
jurisdiction shall not invalidate the remaining provisions of the Agreement.
(rev. 05,/18/2018) Page 2 of 3
ature) Date:
) ss.
THIRD JUDICIAL DISTRICT )
name)
The foregoing inpr ent was acknowledged before me this I --day of oed"'S!
20A, by 6LLdAAt %ii2Y1
(rev. 05/1.8/2018) Page 3 of 3
�
sHorT '•,
NOTARY PUBLIC FOR AL SIC
o�
,,�'��S:�o's
�'
Nly Commission expires.:
5 -
' 1�0'. �OTAR Y ��'�
.t
-j
OF
0,7�A��;;�,
MUNICIPALITY'
By;
(signature)
Date: I0 /9 Z 1
(print name)
Title:
(rev. 05/1.8/2018) Page 3 of 3
GRr"~I~R ANCHORAGE AREA BOROb~ '~
HEALTH DEPARTMENT *~T.O
327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
829
LOCATION
SEPTIC TANK:
MAILINGADDRESS ~,~', t'~'~ i~)2~ ;'~4tg,..F.4~I/~Z../JI, R~-t©NE G&'~'-~¢~2
LEGAL DESCR PnON
DISTANCE FROM WELL~'~2 ~tL~'u)Tll~,l]'J
LIQUID CAPACITY /~-~(~ GALLONS.
NUMBER OF
MATERIAL,kJ'~'/~/~ .~7~ / .~1~110~£.1), COMPARTMENTS
LIQUID
INSIDE LENGTH ~ INSIDE WIDTH -- DEPTH
SEEPAGE SYSTEM:
NUMBER OF PITS
LINING MATERIA[
NEAREST LOT LINE
SEEPAGE PIT:
OUTSIDE DIAMETER
OR WIDTH ~)C) , LENGTH ~)~0 I . DEPTH
DISTANCE FROM WELl /~')C~ j'~c~u)/~/) , BUILDING FOUNDATION
TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~b(~ SQ. FT.
TILE DRAIN FIELD:
DISTANCE FROM WELL/~20~ //~'~//l/~O , FOUNDATION /~' J~,~i'~/l NEAREST LOT LINE.
NUMBER OF LINES ~:-~- DISTANCE BETWEEN LINES -- TRENCH WIDTH
ABSORPTION AREA ~ (~ ;~ SQ. FT. LENGTH OF EACH LINE ~/~'~,. ~ % :'~ ~)
DEPTH: TOP OF TILE TO FINISH GRADE -~ DEPTH OF FILTER MATERIAL BENEATH TILE
TOTAL LENGTH/)/
OF LINES
IN. TOTAL EFFECTIVE
~-~'"' IN. ABOVE TILE
WELL:
LOT LINE
DISTANCES:
DISTANCE FROM -- WATER
TYPE/~?~s¢~. . DEPTH , BUILDING FOUNDATION. SAMPLE
NEAREST
NEAREST . SEPTIC x SEEPAGE ~ -. OTHER
SEWER LINE - TANK ~-~) ~/~) SYSTEM ~/~/~'~..'CESSPOOL , SOURCES
DIAGRAM OF SYSTEM
. . . ~ - -
GREATER ANCHORAGE AREA BOROUGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
3500 TUDOR ROAD POUCH 6-650
ANCHORAGEi ALASKA 99502
TELEPHONE 279-B686
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
,NSTALLAT,ON LDCATION
INSTALLATION OF: SEPTIC TANK
TYPE AND SIZE OF FACILITY TO SE SERVED
FINANCED THROUGH i~L~ ~/1~
/ SEEPAGE PIT HER
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCES, REQUIREMENTS
FOUNDATION TO SEPTIC TANK ~J
FOUNDATION TO SEEPAGE PIT
If;./
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK , SEEPAGE PiT , DRAIN FIELD
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK SEEPAGE PIT
DRAIN FIELD ALSO CONSIDER AREA WELLS.
~> I~
WATER MAIN TO SEPTIC TAN~ , S~EPAGE PIT
DRAIN F~ELD g ~-
SEPTIC TANK, . ~'' ., SEEPAGE PIT , DRAIN FIELD
_, DRAIN FIELD
DIAGRAM OF SYSTEM
TO RIVER, LAKE, STREAM.
. CAS.T~. RON tN~O--AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PI~
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
HEALTH AUTHORITY
OR
LICENSED DESIGNER
~ CERTIFY THAT I AM FAMILIAR With THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
'<ATER ANCHORAGE AR}iA BOROUGH
HUALTII DEPARTMENT
327 EAGLE STREET
ANCHORAGE, ALASKA 99501
CASE ii
u
pel*formcd For .
This Fcrm
Dep~.h
Feet Soil Characteris:ics
-~/~ ~ ' ,
2 Block 2 .'.Sub-~Iv-q--si'~n_.L.a.kerid~_Terrace "
' '¥ercolatio~ Test ......
Location Sketch
· Reading Da~e G~oss Time Net Time Depth To ~20. Ne~ D~op
e:~colal ~ _
2~oposed instal~ion:~Seepage Pit "~" D~ain Field ~-~
Deoth Of Inlet
~ eptn To Bot.~om Of P~ O~ TP
~OYM;,U~,, ,~ ~"'. . - . ~ ench
~~'c~.,-,~<~ J-Zt~ ~ ~' ~ F... ~ ~ . .,// ~ - ~ ..
Da~a Certified By;
GRE'-'ER ANCHORAGE AREA BDt' UGH
INSTA'LAT,ON LODAT,ON
INSTALLATION OF: SEPTIC TANK
TYPE ANB Sl~g OF FACILITY TO B~ SERVED
~NANCED THROUGH
SOIL TEST RESULTS
DEPARTMENT OFENVIRONMENTAL QUALITY
,,,,0 ,,c,, STREET ANC,-,OR*GE, A'-ASK* '"'0'
Di;~O;AL ~Y2T:M -~ APPLICATION AND PERMIT
SEEPAGE IT
% TO be INSTALLED bY ~A ~ ~ ~
NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED
FINAL iNSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE TYPE SEEPAGE ARea SIZE TYPE
DIAGRAM OF SYSTEM
MINIMUM DISTANCES, REQUIREI~IENTS
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE PIT
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK , SEEPAGE PIT
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK
DRAIN FIELD
WATER MAIN TO SEPTIC TANK
DRAIN FIELD.
SEEFAGeF,T /
ALSO CONSIDER AREA WELLS.
SEEPAGE PIT
DRAIN FIELD
SEPTIC TANK, , SEEPAGE PIT
TO RIVER, LAKE, STREAM.
,, DRAIN FIELD
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
LICENSED DESIGNER
I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORA_~j~ArEA BOrOUgh ORDINANCE NO. 28-68 AND THAT THe ABove
DESCRIBED SYSTEM IS IN~ACCORDA~E WITH SAID CODE. ~///~ ~
DEPT. OF ENVIRONMENTAL CONSERVATION /
/
SOUTHCENTRAL REGIONAL OFFICE / 338 DENAL/ STREET
/ MACKAYBUILDING-ROOMS"rO
ANCHORAGE 99501
October 24, 1975
Mr. Rolf Strickland
Anchorage Municipality
3330 C Street
Anchorage, AK 99503
Subject: Lot 2, Block 2, Lake Ridge Terrace (Gaard)
Dear Mr. Strickland:
This office has no objection to the use of the old semi public
distances with regard to protective radii if the duplex was
constructed prior to August 1973 and if the 200 foot requirement
will cause undue hardship.
Sincerely,
Kyle~J. Cherry, ~. Eo
Regional Environmental Supervisor
ec~ Ronelva Gaard