Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LAKE RIDGE TERRACE BLK 2 LT 3
s } is required for aproval of future C ;vzMs (Refer *''' Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP141341 PID Number: 051-315-24 Dwelling: ❑■ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New 9 Upgrade Name: John E. James ABSORPTION FIELD ❑ Deep Trench 9 Shallow Trench ❑ Bed ❑ Mound Address 18308 James Way, Eagle River AK 99554 ❑ Other Phone Number of Bedrooms 1. Soil Rating Total depth from original grade 3 1.2 GPD/SF 2.6 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 6 I Gravel depth beneath pipe 2 Subdivision Block Lot Lake Ridge Terrace 2 3 Ft. Ft. Fill added above original grade Gravel length Township Range Section 1-2 Ft. 1 53 Ft. Gravel width 5 Beds: Number of Lines Distance between lines SEPARATION DISTANCES To Septic Absorption Holding Sewer Lift Station Ft. Total absorption area Number of trenches Ft. Dist. -between trenches From Tank Field Tank Line 37$ Ftp 1 Ft. Well >100' >100' >100' NA >25' TANK ❑ Septic 9 S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Surface Water >100' 65' >100, NA Anchorage Tank 11,250 Gal. Material Number of compartments Lot Line >5' 1' >5' NA Steel Three NA Foundation >5' >10' >5' NA LIFT STATION Manufacturer Capacity Curtain Drain I None I Noted Anchorage Tank/Orenco 250 Gal. Remarks See Waivers to Lot Line and Surface Pump on level at 42 Pump off level at 38 High water alarm at 44 Water. in. in. in. Pump make and model OSH P2005-11 Electrical Inspections performed by Walker Electric Installer PIPE MATERIAL House to tank D3034 Tank to grainfield D3034 Green Construction Drainfield D3034 CO/MT Inspector A. Harala BENCH MARK (Assumed elevation) 100.0 ft Inspdates: 1ection" 10/22/14 2nd 10/23/14 Location and description 3rd 10/24/14 4"' Garage Slab. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp k7 ♦AV Conditional Approval: Date 4V k •j� All �; • `••� • ' 49thon ... . ,l... .�......... MICHAEL E. ANDERSDN j Approved 411 �•®� •No. CE-4381�s (, Date 0iy�sw�a�•s Inspection ReDort A-1-19 rinn ,oil C) 't CF) ll� CY) z w cCDO F - w Lo < 0ui 0 < U) W 0 > 0 w M U) < z W co 0 ?� W CU > CD w M nm 0 (1) C:) O 0 (Y) I x C) q C) a) 3: C) Cl) LO 00 00 z \1 Nr w 0 xg, 9;r- e- C) w 0 w -Z6 U- < (D 17- 'T > 00 --o 0 -t-. W oo c c US O CS 'E Nr �2 c`ih ry rZ .0. o 0 o> c cc 0 cu a) o Cl co 'n W 0 zo E w � F- �' 6 c6 q; 0 co Z (-q 0 C11 N co w m < co W— C) LL _,2 C (D C) CM C� 0 C_ .0 CM E (D - >, (,u < -� U) cn:r- 0 F– w 0 o < w co 0 z w S w = 0 0 061 —J "0 (Y) I x C) q C) a) 3: C) Cl) LO 00 00 z \1 Nr w 0 xg, 9;r- e- ts 'o 0) 10 N, cn E U) D IX 004) E 2 2 is-oamo L2 m 8 vai IT I 1 0/0 cc I W a. 00'06 4 3..00.LO.00N %C 0 acFll ajo4s w w w U- W oo c c C o .0 w .0. o 0 o> E FD E (D zo E N 0 co Z (D C a =3 a) 0 < co _,2 C C: C� 0 C_ .0 CM mc U) -2 - >, (,u < -� U) cn:r- 0 F– W C -�; C o < w co 0 z w S w = 0 Permit Number: OSP141341 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Page 3 of 3 PID No. 051-315-24 NOTE: Existing Septic Tank Decommissioned in Accordance with Municipal Code. Existing Absorption Area Removed in Its Entirety and Replaced With Clean Coarse Sand. Bedrock 53' (Trench Length) PROFILE AS -BUILT - No Scale 94.9 ` 49th .... .. ............,,........... MICHAEL E. ANDERSON No. C7E-413381 PA�.�FESS1.1A On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP141341 Tax Code Number: 05131524000 Work Type: Septic Upgrade Permit Effective Dates: September 04, 2014 to September 04, 2015 Design Engineer: ANDERSON ENGINEERING Subdivision: LAKE RIDGE TERRACE Site Legal Address: LAKE RIDGE TERRACE BLK 2 LT 3 G:0653 Owner/Address: JAMES JOHN E 18308 JAMES WAY EAGLE RIVER AK 995779254 Site Mailing Address: 18308 JAMES WAY, Eagle River Lot Size in Sq Ft: 45500 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By Municipality of Anchorage P.O. Box 196650 0 4700 Elmore Road Anchorage Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.muni.orn/Onsite Development Services Division On -Site Water and Wastewater Program anent S e y .epartment **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP141342 COSA#: Permit#:OSP141341 P I D#: 051-315-24 Legal Description: Lake Ridge Terrace, Block 2, Lot 3 Engineer: Anderson Engineering Applicant: John James Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 1.0 foot. Your request for a waiver of the required 100 feet horizontal separation from the absorption field to the surface water has been approved. The approved separation distance is 65.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ® The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. ❑ Adjacent properties are not affected by this waiver. ............................................................... a . . . . . . . . . . . . . . . Waiver is Granted: X Waiver is not Granted: Date: q 4 / Approved by: . Name of Reviewer ........................................................................... MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-315-24 Property owner(s) John James Mailing address 18308 James Way Eagle River, AK 99577 Site address Same Day phone Legal description (Sub'd., Block & Lot) Lake Ridge Terrace, Block 2, Lot 3 Legal description (Township, Range & Section) Lot Size 45,500 Sq. Ft. Number of Bedrooms Three (3) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: S±oCI (® all that apply) _S 2l5 k 6�iy�� _ �S% Absorption Field ❑ Initial ❑ Single Family (SF) ❑ Septic Tank ❑ Upgrade ❑ (w/wo ADU) ii19 G Cf Duplex (D) ❑ Holding Tank ❑ Renewal ElMultiple O�i ,?.?G - Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑bqUAMi` 519j,it 5q,-7 Water Storage ❑ AUG ' c 201 THIS APPLICATION IN LUDES Al VARIANCE I WAIVER REQUEST FOR: Arm%", % alb �6 $c7�a La wm"4eo fay" Lot Line Waiver Distance: 1' I certify that the above information is correct. I further certify that this is in accordance with Codes. applicable Municipal Code /'Jj FE � (Signature of property owner or authorized agent) Permit/Rush Fees: S±oCI Waiver Fees: _S 2l5 k 6�iy�� _ �S% Date of Payment: C4 -x Date of Payment: ii19 G Cf Receipt Number: OtQJ 6. Receipt Number: O�i ,?.?G - Permit No. O 51,11 Waiver No. C 519j,it 5q,-7 Permit App_9-1-12.doc ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) August 16, 2014 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 3, Block 2, Lake Ridge Terrace Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer The existing septic system on Lot 3, Block 2, Lake Ridge Terrace Subdivision has failed and must be replaced. We are therefore requesting a permit be issued for the construction of a new septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system along with the existing system. No existing wells are closer than 100' from the proposed system. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The area available for a septic system on this lot is limited by the location of the existing well and Fire Lake to the south. The existing septic system must be removed in its entirely and the excavated area replaced with clean coarse sand. All contaminated material must be removed to provide room for the new system. The existing septic tank will be removed and decommissioned in accordance with Municipal Code. The existing absorption trenches are located more than 1' below the bottom of the new septic system and is a total of 6' below existing grade according to Municipal records. The new trench will be placed between the existing trenches in undisturbed ground. The test hole placed on the lot in the area of the absorption trench indicated gravel with sand and silt (GM). The percolation rate of the soil was determined to be 1.4 minutes per inch. No groundwater was found during the placement of the test hole and none was noted during the monitoring period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250 -gallon STEP tank and a 53' long by 5' wide by 2' effective depth absorption trench to treat and dispose of the effluent generated in the house. The Lot 3, Block 2, Lake Ridge Terrace Subdivision August 16, 2014 Page Two elevation of the distribution line in the absorption trench will be 1' below the surface and the total depth will be 3'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trenches and 4' over the STEP tank. The ground surface on the lot in the area of the absorption trench slopes to the south and west at a grade approximating 2%. The new trench will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' from the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, l Michael E. Anderson, P.E. Attachments MICHAEL E. ANDERSON No. cE-,.381 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766(FAX) August 16, 2014 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 3, Block 2, Lake Ridge Terrace Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The area available for a septic system upgrade on the subject lot is limited by the location of the well on the lot and the presence of Lower Fire Lake. The only location available is near the location of the existing absorption system and within 1' of the west property line. The trench does not impact the property to the west as it is more than 100' from all wells in the area and more than 10' from all septic systems in the area. We recommend a waiver be issued allowing the trench to remain 1' from the west property line. Sincere Michael E. Anderson, P.E. �' 49th •° � MICHAEL E. ANDERSON . No CE -4381 . ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) September 4, 2014 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 3, Block 2, Lake Ridge Terrace Subdivision Absorption Trench to Surface Water Waiver Dear Onsite Services Engineer: Very little surface area is available for construction of a septic system on Lot 3, Block 2, Lake Ridge Terrace Subdivision. The new absorption trench is proposed for the same location as the existing failed trench in the northwest corner of the lot which is located 65' east of a section of Lower Fire Lake. A waiver is therefore necessary from the 100' setback required by ordinance. The slope of the ground surface surrounding the absorption trench is directly to the south at grades from 5% to 20%. The edge of the water in that direction is more than 100'. A 6" high berm 2' wide at the base will be placed at the western lot line to prevent any cross lot drainage and to direct effluent if the system should ever overflow to follow the natural drainage path to the south. The effluent will flow a minimum of 100' before it would encounter surface water. The soils underlying the absorption trench are very good to excellent. The likelihood of a failed septic system and overflowing effluent are very low. The existing absorption system is in failure and no surface drainage is apparent. We therefore recommend the waiver be issued allowing the proposed absorption trench to be 65' from the edge of Lower Fire Lake. Sincerely, Michael E. Anderson. P.E. i I / ° W / °` z a p U N rQ USO O "6 o = < O Z N N p f/i J O II WW co 2 u2 O W>=O F-0 m 3m W m JIn2U2Lt F- Ing U W o Q' y / io moa Vo , — N z¢ g / sso m 100 J \ 9�ti 0 \ \ / ®� 10 0 1 N lLL 1 1 �PMa�/o o W > U W JO Ul OJ F--� E w_ \ / o U K v7 a m u \ o c MZ Q N .W H + X O �0 mom 0 3 o N p E0 I S _ `o/ � -2 tqN Q N =O .� _e OsrmW 2 p� u c o ffiS c�F W 0 -a C N �(yq Oo O O O N W<F= 1,I = N N p1 ZOQ W CU s c � w i VO 3 xS' 00'061. 3;,0010.00N m d �°fid., v : : o •,p LOT 2, BLOCK 3, LAKE RIDGE TERRACE SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS Three Bedroom Home 5' Wide Trench System Perc. Rate: 1.4 Min./Inch 1,250 Gallon STEP Tank Application Rate: 1.2 GPD/SF 2' Drainfield Rock Pressure Distribution System 3 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 375 SF Absorption Area 375 SF/5 SF/LF--7 (Red. Factor) = 52.5 LF Trench Length THEREFORE: Construct a 53' Long x 5' Wide x 2' Effective Depth Absorption Trench at the Location Shown. Flow Line Elevation in Trench to be 1'0" Below Original Ground Surface. Total Depth to be 3' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption 5' Remove All Remnants of Existing Septic System Dispose in Accrodance with Municipal Code Backfill with Coarse Sand to Replace Contamination TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. Revegetate Mound Area Natural ith 6" Topsoil Backfill 2" Insulation 6" Geotextile Fabric 6" 1" Perforated PVC (Holes Down) 30 Holes 3/16" Dia. @ 1.75' Spacing 2'0" Drainfield Rock 5' Remove All Remnants of Existing Septic System Dispose in Accrodance with Municipal Code Backfill with Coarse Sand to Replace Contamination TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LAKE RIDGE TERRACE BLOCK 2 LOT 3 PERFORMED FOR: JOHN JAMES DATE: 7/21/2014 PARCEL ID#: PROJECT No.: _ TECHNICIAN: JB TEST HOLE I SLOPE ROUND WATER ENCOUNTERED? NO IF YES @ WHAT DEPTH? NET TIME (MINUTES) OF WATER AFTER MONITORING:NONE NET DROP (INCHES) DATE OF MONITORNG: 7/31/IG Com;' .` 49th MICHAEL E. ANDERSON NO. CE -4381 . SITE PLAN SEE SITE PLAN 2 a` DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To MATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 9/25 1 1:53/2:03 10 1s0^/8.88° 7.38" 2 2:04/2:14 10 1.38"/8.63" 7.25" 3 2:15/2:25 10 1.50"/8.75" 7.25" 4 2:26/2:36 10 1.38"/8.63" 7.25" 5 237/2:47 10 1.38"/8.63" 7.25" 6 2:48/2:58 10 1.50'/8.75" 7.25" PERCOLATION RATE: 1.4 (MIN/INCH) PERC. HOLE DIA. 5 (INCHES) TEST RUN BETWEEN: 3.0 FT. and 4.0 FT, COMMENTS: TEST HOLE PRE SOAKED PRIOR To TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 8/16/201L GAAB-HD-I GgFVER ANCHORAGE AREA BOROL ;H HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM I nr ATnn SEPTIC TANK: EGAL &II If' q--2yi;i MAILING ADDRESS Cbt � �` PHONE DESCRIPTION ` I R. e4 r' G NUMBER OF i DISTANCE FROM WELL 1 MATERIAL COMPARTMENTS— >4e OMPARTMENTSace LIQUID LIQUID CAPACITY 5 GALLONS. INSIDE LENGTH INSIDE WIDTH DEPTH SEEPAGE SYSTEM: SEEPAGE PIT NUMBER OF PITS OUTSIDE D R OR WIDTH , LENGTH ,. DEPTH_ LINING MATERIAL . DISTANCE- WELL tyuILDING FOUND { NEAREST LOT LINE TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL 1;t—/ 1 /© s � TOTAL LENGTH FOUNDATION NEAREST LOT LINE OF LINES— NUMBER 9� NUMBER OF LINES DISTANCE BETWEEN LINES ` ��–TRENCH WIDTH IN. TOTAL EFFECTIVE ABSORPTION AREA q / SQ. FT. LENGTH OF EACH LINE / y L.1 DEPTH: TOP OF TILE TO FINISH GRADE / DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE L DISTANCE FROM ✓_t WATER WELL: TYPE ZZe-W , DEPTH D S BUILDING FOUNDATION. I( SAMPLE , NEAREST NEAREST SEPTIC C3' SEEPAGE`/Ii OTHER LOT LINE SEWER LINE , TANK 7 SYSTEM CESSPOOL SOURCES= DIAGRAM OF SYSTEM DATE / ✓�'T� 1 APPRO lei 1'�R� GARB- "-2 ` GREATEL. ANCHORAGE AREA 3ROUGH Case No. HEALTH DEPARTMENT 327 Eagle St. Anchorage, Alaska 99501 279-2511 SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT NAME OF APPLICANT ' 40 MAILING ADDRESS %O -'—I, - PHONE NO. ` RESIDENCE ADDRESS ZdL TAI r%2ZV ��LOCATION OF INSTALLATION LEGAL DESCRIPTION L S 2� `a kE %d IT)&F 7`racL S�Vhb, APPLICATION TO INSTALL: SEPTIC TANK L-'-� , SEEPAGE P�IIT , DRAIN FIELD L"" , OTHER TO SERVE THE FOLLOWING FACILITY �;F/)e� FINANCED THROUGH i TO BE INSTALLED BY ���i IUN/Nsl AAAA X01ANTICIPATED DATE OF COMPLETION - BELOW A}DP7 D[D6 TEST RESULTS BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT G THIS IS TO SERVE AS �' "' l�� PERMIT TO INSTALL AC22L�� AS DESCRIBED BELOW. SIZE OF UNIT TO BE SERVED SEPTIC TANK SIZE%fir TYPE :5-1 ei SEEPAGE AREA TYPE Vl��}t rPl DIAGRAM OF SYSTEM DISTANCES: r%7r1 (20k) Gpz'm 40 all 6 -rave/ 49fo 1 HEALTH AUTHORITY OR LICENSED DESIGNER EEE■E■E■EEE■E■EEE■MIN■E ■E■■■11N1111�M EEE■■�'I iQ, EME■■■MIME■■ a ■■N■■■■ONMIMIi■■■■■■■■■■ -I■■■■■■■■MIEN ■■■■■■■■■■■■■■■■■■NONE ■■N■■■■■O■■E■■■■E■E■■E ■■■O■MINE ■MOM NON■EN■O ■■i►■�1.�.■�■fir■■■■�■IMM■■■■ ■E■■N■■EEEEE■■■E■■■E■E E!�IEE■�J E■EMI!■■EMIE■�>�■E■ ■■■■■■■■■■■■■i■■■iii■■■ Ill■■EEEE■■■■■N■■■■E■■EN I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the above described system is in accordance with said code._ ��/1 • �� / �� /i �- nATE `� / e3 APPI WAN�TR SIGNATURE EC,`-tY KTV AM Y. lot 4 Al I horeby certify that I We survoyed the following qescrlbOd property: LOT 32 Block 2, Lake Ridge Terrace Subd.,SE4 V4 Sec. 2& T154 R2W) SM, Alaska, Anchorage Recording Precinct, and that ihe: improvem,ntep as proposed by the Buil-Jarp will be within the prOPPUY lints and should not ovorlap or encroach upon WONKY TYIng vdi0c", thereto, thot no Impl"Vementy situated on ndjocal" proparty upon the. LOT in quastion, and WK there Pre, W) 10P8, or other WNW movnmOnts On said LOT Ox"K as mAy bo "jI('Yt Dated U Eagle River; Ala5ka this 116th- day of April, 19709 1,10. Regiaterm SREATER ANCHORAGE AREA BOROUGH' HEALTH DEPARTMENT CASE 327 EAGLE STREET ANCHORAGE, ALASKA 99501 Performed For , T"11 Date Performed 2,5- Lega-. Description: Lot Block Subdivision �i)l��pr %-itre �crk (lUfrP R«J�e IPmo�) This I'crm ReYol4ts a: Sob1s Log, ercolaticn Tesi:ice Depth F'ec:s Soil Characteristics 1je tlils CGSe- t is &Ck-j Il. The pore -A ma4ericd `j (fedroc,k w;! Gct�' ,M Cpprox�.�lif2 1'- Z --6psa; veneer, S-� t Location Sketch Was Ground Water Encountered?�% 0 If }'est At What Depth rroposed Installat�io Seepage Pit Drain Field Depth Of Inlet Depth To Bottom Of it Or Trench COMIMENTS '.if:IP 1- CP or.,.o '1 .: , m0 .�- Q'L ,_.. %1 / 1 I..__ — �• Test Performed By: Data Certified By:�d/1M Q1 l� Dater 1C ",` , 11 5. LEGAL DESCRIPTION /-6 t, .� (?fie C✓II< L e, -4c' DATE RECEIVED INSPECTION APPOINTMENTS 6. TYPE OF RESIDENCE NUMBER OF,BEDROOMS TIME TIME TIME // ❑ MULTIPLE FAMILY CO"' Three ❑ Six gs.TE DATE DATE C Q���0� ❑ PUBLIC UTILITY depth (attach log if available.) INSPECTOR INSPECTOR INSPECTOR 112 70 YEAR ON-SITE SYSTEM WAS INSTALLED. MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPT. OF !!'`.`.LTH £. DEPARTMENT OF HEALTH & ENVIRONMENTAL PRft6CL4'C4 N!cNTAL TLCTION 825 L Street - Anchorage, Alaska 99501 • AUG 2 9 1980 ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 R E C E RIES REQUEST FOR APPROVAL OF INDIVIDUAL WATER ANDSEWER FA DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER + PHOONE MAILIN ADDRESS - �� Q� ^� PROPERRT_�Y RE DENT (if different from a e) PHONE Z-0w'� f e� 2. BUYER PHONE MAILING ADDRESS 3. LENDING INS TION PHONE MAILING ADDRESS L od-t e - A�'� i 4. REALTOR/AGENT V PHONE MAI LING ADDRESS 5. LEGAL DESCRIPTION /-6 t, .� (?fie C✓II< L e, -4c' STREET LOCATION (' �//�� �j'/ J 6a (ir, P $ k'AC !s k 6. TYPE OF RESIDENCE NUMBER OF,BEDROOMS C FAMILY ❑ One E:1 Four E__1 Other SINGLE ❑ Two ❑ Five ❑ MULTIPLE FAMILY CO"' Three ❑ Six 7. WATER SUPPLY UK INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM I' INDIVIDUAL/ON-SITE** 112 70 YEAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6/79) 5 n THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ TWO ❑ THREE ❑ FIVE ❑ OTHER ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON -SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER DATE INSTALLED INSTALLER ❑Septic Tank or ❑ Holding Tank Size: I 5-0 0 If Tank is homemade give dimensions: SOILS RATING w TYPE OF TANK MANUFACTURER TOTALABSORPTION AREA MATERIAL 1 4. DISTANCES WELL T0: Septic/Holding Tank Absorption ea Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS ❑ APPROVED FOR BEDROOMS 1❑_ `CONDITIONAL APPROVAL (letter must accompany certificate) I DISAPPROVED DATE � 9-(240 BY Mr. John E. James P.O. Box 733 Eagle River, Alaska 99577 DAVID A. SLEN KAMP MECHANICAL ENGINEER 694-9055 September 12, 1980 ROBERT A. SHAFER CIVIL ENGINEER 694-2979 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION SEP 15 1980 RECEIVED Dear Mr. James, Reference: Lot 3; Block 2; Lake Ridge Terrace Subdivision As you requested, a sewer system adequacy test was performed on the sewage system located on the referenced property and serving your three bedroom home. Approximately 574 gallons of water was added to the leaching field through continuous flow over a period of 24 hours. There were no adverse effects from this test. Therefore, it is concluded that the leaching system is currently providing adequate percolation. The septic tank was pumped and verified to have a capacity of approximately 1250 gallons. I have concluded from this test that the sewage system is currently functioning adequately. If we may be of further assistance, please do not hesitate to call, Singly, R 'BERT A. SHAFER, P.E. ,�S/ss cc: First Federal Savings and Loan Association Municipality of Anchorage Department of Health and Enviornmental Protection SRB 196X EAGLE RIVER, ALASKA