HomeMy WebLinkAboutLAKEWOOD HILLS #3 LT 31Onsite File
Lakewood Hills
#3
Lot 31
#015-134-10
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax* (907) 343-7997
http://www.muni.orglonsite �Z_ - ftli_
Jepartinent
On - Site Wastewater Disposal System Permit
Permit Number: OSP201428 Effective Date: 10/16/2020
Work Type: SepticTank Upgrade Expiration Date: 10/16/2021
Tax Code Number: 01513410000
Site Legal Address: LAKEWOOD HILLS #3 LT 31 G:2540
Site Mailing Address: 7600 UPPER O'MALLEY RD, Anchorage
Owner: KELSON NADYA TRUST Lot Size in Sq Ft: 16000
Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 3
This permit is for the construction of:
0 Disposal Field 0 Septic Tank 1771 Holding Tank 0 Privy 171 Private Well d Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (1 8AAC72) and Drinking Water Regulations (I 8AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
1. Once separations to surface water and wells has been established, the distance between the septic tank and
absorption field shall be maximized (up to at least 5 ft if possible). Any required waivers shall be applied for with
the inspection report, if required.
2. A ROW permit shall be obtained for the absorption field located partially in the Utility Easement prior to
inspection report approval.
am=
:
Date
Date:
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201428, Rebecca Carroll, 10/16/20
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201428, Rebecca Carroll, 10/16/20
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201428, Rebecca Carroll, 10/16/20
" Municipality of Anchorage Page / of ~--
, DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: ~'/.~'~.,~._~9~) PID Number:
,~m~6~ ~ ~ ~F~~ ~astewater System: ~New U Upgrade
~ ~,~~ ~. ~[~ ABSORPTION FIELD
Phone: No. of Bed,s: ~Deep Trench ~ Shallow Trench ~ Bed ~ Mound ~ Other
LEGAL DESCRIPTION SoilRating: ~'~ GPD/Sq. Ft. Total Depth from original gr~d~: /
Lot: ~/ Block: Subdivision: ~pth to pipe bottom f rom origina~ad~: Gravel depth beneath pipe
Township: Range: Section: Fill added above original grade:~ ~Ft./ Gravel length: ~ /Ft.
Number of lines: ]Distan~een lines:
WELL: D New D Upgrade Gravel width: ~/ Ft. / I '2/~ Ft.
C~ication (Private, A,B~): ~ Total Depth: Cased To: Total absorption area: Pi~e material:~/~
Driller: Date Drilled: StabcWaterLevel:F,. Installer:~~ ~¢~ Dateinstal
Yield: GPM Pump Set at: Ft. Casing Height Above Ground:Ft. TAN K
SEPARATION DISTANCES ~Septic D Holding B S.T.E.P,
TO Septic Absorption Lift Holding 'ublio/Private ~:ctur, r: . Capacity in gallons:
From Tank Field Station Tank S .... Lines ~ ~~~
Well /~¢ /~/ ~ Z~ Material: Number of Compartments:
Su,f~w~r /~/~' II~' ~ ~ ~ LIFT STATI~/
~ot /~ / /W / ~ S~z~,.ga,,o.~:
Line ~
.ound~,ion 14' Z~' ~ ~ ~ ".um.o.".~"".=.
Curtain _ Electrical
~.ain ~ ~O~¢ l~,~Z .~m~Mod~, ,ns.~,,onsp~r,o.m~.:
Remarks: BENCH MARK
Location and Description:
ENGINEER'S SEAL
Inspections performed by: 34E~leE~erL~d,~ 1st ~, /,~ ~"'
Eagle Ri~er, Alaska ~577 2nd ~/~
Department of He d Hua rvic~s appr~all
Reviewed and approved by: ' Date' / ~ /
72-013 (Rev. 9/91) MOA 25
Permit No. S~,~!930Z00
Page 2 of 2
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
LAKEWOOD HILLS #3, LOT 31
Legal Description:
PID No..0151'5410
CO1
N.T.S.
C02
99'-
~-...-
9s.~'
MT C04
87.3
· 81.3'N0 WATER FOUND
UTIL. E
i A B
FC0 24 6.5
C01 34.5 15.5
C0M 37.5 21.5
C03 54.5 33
C04 25,5 38,5
MT 34 g7.5
~RENCH ~
3 BDRM.
FOUNDATION
100' WELL RADIUS
100' WELL RADIIUS
o
looo ck'h
TANK
SCALE f' = 40'
72-013 A (2/91) MOA 25
ENGINEER'S SEAL ..
.::~-~.', '~.'~t'~'~'- ~ ~
~" %,; 2 · ,: ,',:.~ V/ ~ '~,~'
._.
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW930300
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:ALASKA CORP OF SEVENTH DAY
OWNER ADDRESS:6100 g'MALLEY ROAD
ANCKORAGE, AL 99516
DATE ISSUED: 8/13/93
EXPIRATION DATE: 8/13/94
PARCEL ID:01513410
LEGAL DESCRIPTION: LAKEWOOD HILLS #3 LT 31
LOT SIZE: 16000 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AACS0).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4329 OR 343-4681 AFTER BUSINESS HOURS
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY: ~'~,
-
ISSUED BY: / /
DATE:
ROBERT SHAFER, P.E.
ROGER SHAFER, P.E.
AuguSt 9, 1993
CIVIL ENGINEERS
(907) 694-2979
FAX 694-1211
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ON SITE
WASTE WATER
DISPOSAL SYSTEM
DESIGN
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
825 L. Street
Anchorage, AK 99519
REFERENCE: Lakewood Hills Subdivision, No. 3, Lot 31
We request you issue a permit to drill a well and install a septic
system to serve the proposed 3 bedroom houSe on the referenced
property.
A test hole was excavated and percolation test performed on the above
referenced property. The approximate location of the test hole is
located on the attached site plan.
Th~ property has enough area for a fu~e septic upgrade, which can
be seen on the at~ched site plan. We do not anticipate any adverse
effects on n~ighboring properties by the installation of the proposed
septic system.
If you have any questions, or require additional information for your
review, please contact uS.
ERT A SHAFER, P.E~As/gk .
17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502~0650
SOILS LOG -- PERCOLATION TEST
Township,
Section:
SLOPE SITE PLAN
10
11
12
13
14
15
16
17
18
19-
20-
WAS GROUND WATER
ENCOUNTERED?
S
L
IF YES, AT WHAT O
DEPTH? P
E
Depth to Water..A,J~,-~,? ;, ~'~
I~onitoring? ~ Date:
Gross Net Depth to Net
Reading Date Time Time Water Drop
~ : ~1~ ;~ ~ ~/'~ .Y.~ ,
~:SI 2 H
PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN C~,E-'~ FTAND "~',~ FT
COMMENTS
PERFORMED BY: ~ g 5 EI~GINFgI~IN6 I "~" ~ -~ CERTIFY THAT THIS TEST WAS PERFORMED IN
17034 Eanle River Looo RoadNo. 2~ T ON T~IS D ~¢ ~ ~ ~C;~,%.
ACCORDANCE WITH ~.~.N~~¢UIDELIRES"IN EFFEC ATE. DATE:
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Lakewood Hills Subdivision, No. 3, Lot 31
GENERAL:
1.
o
o
The scope of this project includes the installation of a
1000 gallon septic tank and a leachfield trench to serve
the proposed three bedroom residence on the referenced
property.
Construction shall be in accordance with the approved
site plan and design drawings; Municipal permit with any
special provisions or conditions; and all applicable
State and Municipal Wastewater Disposal Regulations.
The contractor shall be responsible for obtaining any
necessary underground utility locates.
Unless specifically agreed otherwise, the property owner
shall be responsible for final grading areas subsequently
depressed from soil settling. On all leachfield mound
systems, the property owner shall be responsible for
ensuring a satisfactory vegetation growth over the
mounded area.
Contractors installing wastewater disposal systems must
be certified by the Municipal Health Department for
system installations. Owners installing their own
systems must also receive prior approval from the
Municipal Health Department.
SEPTIC TANK INSTALLATION:
A septic tank is to be constructed by a certified septic
tank manufacturer. Construction shall include two 4"
cleanouts for pumping access.
o
The septic tank shall be sufficiently bedded to prevent
settling or shifting of the tank.
o
Ail standpipes on the septic tank shall extend a minimum
of 12 inches above final grade.
4. Septic tanks installed with less than 4 ft. of cover
shall be insulated.
Page Two
Lakewood Hills Subdivision, No. 3, Lot 31
August 9, 1993
o
A foundation cleanout shall be installed one to four feet
from the building foundation. In the line between the
tank and the leachfield there shall be two adjacent
cleanouts (unless an effluent pumping system exists
within the septic tank). These cleanouts shall be
located on undisturbed soil not more than 10 ft. from the
tank. The first cleanout, in line, shall be to clean
toward the leachfield. The second cleanout shall be to
clean toward the septic tank.
Final grading over the septic tank shall be such that a
positive slope exists away from the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensions shown on
the design. The bottom of the excavation shall be within
2 inches of level. If the sidewalls of the excavation
become smeared, they must be raked or scratched ruffed-
up) before gravel (sewer rock) placement.
o
Once the gravel is installed, the distribution pipe is to
be installed level with the perforations faced downward.
Gravel is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
o
A silt barrier must be installed between the final gravel
layer and the native soil backfill. Ensure the silt
barrier covers the entire gravel surface before placing
backfill.
Monitor tubes shall be of four (4) inch diameter and
installed approximately in the locations shown on the
design. The portion of the monitoring tube extending
through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe. This
is equivalent to the effective depth of the gravel as
noted on the design.
Backfill over the final gravel layer must not be less
than twenty-four (24) inches. Insulation must be
installed when the backfill depth is less than thirty-six
(36) inches. The finish grade over the trench must be
mounded to prevent the formation of a depression after
settling.
Page Three
Lakewood Hills Subdivision, No. 3, Lot 31
August 9, 1993
MINIMUM MATERIAL SPECIFICATIONS:
1. Any septic tank 9roposed for installation must be
constructed by a Municipally approved septic tank
manufacturer.
o
The following pipe materials are approved for use in
septic system installations in the Municipality of
Anchorage:
Type of Pipe
Cast Iron
ASTM D3034 (PVC)
ASTM F810 (HDPE)
ASTM D2662 (ABS)
Perforated Solid
Yes Yes
Yes Yes
Yes No
Yes Yes
Use of a type of pipe other than listed above must be
approved by the inspecting engineer.
Insulation shall be at least 2" thick extruded direct
burial polystyrene (Dow Chemical Company Styrofoam HI or
equal).
Septic tank inlets and outlets shall be fitted with
watertight couplings (Caulder, Fernco, or equal
A permeable nontoxic silt barrier (Typar 3401 Mirafi
140N, or equal) must be installed between the final
leachfield gravel layer and the native soil backfill.
Ail leachfield gravel (sewer rock) shall be 0.5"-2.5"
screened gravel with less than 3% passing the #200 sieve.
When sand is being used as a filter material, it's
gradation specifications must conform to AMC 15.65.060D.
Page Four
Lakewood Hills Subdivision, No. 3, Lot 31
August 9, 1993
INSPECTIONS:
Typically there will be a minimum of three (3) inspections
required during the installation of the wastewater disposal
system. These inspections will occur as follows:
The first inspection must be conducted after the
excavation of ditches, pits, trenches, or beds and
before the installation of any gravel. A septic
tank may be set in place, but may not be backfilled
before this inspection.
o
The second inspection must be conducted after the
placement of the silt barrier, gravel, distribution
lines, standpipes, cleanouts, and insulation, but
before the placement of any other backfill.
o
The final inspection is to occur upon final grading
of the property.
Often there will be more than these 3 inspections required.
Especially with the installation of multiple trenches, sand
filters, pressurized distribution systems, etc. Thus, the
inspecting engineer is to be contacted at least 24 hours prior
to the start of construction. If necessary, a pre-
construction meeting will take place on-site.
(907) 243-2282
FAX: (907) 243-4852
JOHF $OH DR LUNG
WATER WELL DRILLING
PUMP SALES AND SERVICE
38 Years Alaska Drilling
CO.
SEPTEMBER 14, 1993
THE BLOMFIELD COMPANY
TONY BLOMFIELD
560 EAST 34TH AVE. SUITE 105
ANCHORAGE, ALASKA 99503
LAKEWOOD HILLS # 3 LT 31
KEN JOHNSON
3163 LINDEN DRIVE
ANCHORAGE, ALASKA 99502
RECEIVED
SEP 2 t 1993
Municipality of Anchorage
Dept, Health & HUman Services
VATER VELL LOG
0 FT TO 37 FT
37 FT TO 47 FT
47 FT TO 55 FT
55 FT TO 103 FT
103 FT TO 123 FT
123 FT TO 134 FT
134 FT TO 147 FT
147 FT
COURSE GRAVEL & BROWN SILT
SAME WITH COURSER GRAVEL ( TIGHT )
MED. GRAV & BRN SLT ( DRILLS OPEN 3~ )
FINE GRAV & BRN SILT ( OPEN HOLE 8' )
SAME WITH CLAY TEXTURE ( WEEPS H20 )
SANDY BRN CLAY SEAMS..HEAVES SLIGHTLY.
DIRTY FINE GRAV & SAND.. WITH H20..
HEAVES 12 FT.
CLEAN MED. & FINE GRAV & SAND..WATER BEARING.,
TEST BAILED ONE HOUR
STATIC WATER LEVEL 75 FT.
BAILED AT 15 GPM
DRAWDOWN 20 FT. ( 95 FT ELEVATION )
BOTTOM STABLE LEFT 18 IN. GRAV IN CASING.
TOTAL CASING 146 FT. 7 IN.
KEN ,JOHNSON CWD/PI
NWWA CERTIFIED
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
Parcel I.D. #
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
015-134-1~' HAA#
1. GENERAL INFORMATION
Complete legal description Lot 31; lakewood Hills Subdivision ~3
Location (site address or directions) 7500 Upper O'Malley Road
Property owner
Mailing address
Lending agency
Mailing address
Carrie Blomfield
7500 Upper O'Malle¥ Road, Anchorage,
Day phone 274-5510
Day phone
Agent Jack White Realty
Day phone 563-5500
Address 3201 "c" Street..quite 2flQ~ An~hnr~g~ AW 995flr
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS: ~ ~'
TYPE OF WATER SUPPLY:
Individual well
Community well
Public water
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status o'f system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. 1/91) Front MOA #21
5. STATEMENT OF INSPECTION BY ENGINEER
o
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm Environmental Manaqement,:nc. Phone 272-9336
Address 206 E. Firew~ l~., ~ite ~/, Anchorage,
DHHS SIGNATURE
~_ Approved for
99503
Date ~/)'-~'/'~ o/
bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
By:
Additional Comments Note: The well for this property meets existing
State and Municipal Codes. There are nitrates present. It is
continued suitability. Nitrate concentration is 5.8 mg/1. EPA
.mum coi~cen~ration ~s i0.0. rog/1.
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-(Y25 (F'ev 1,~1 ) Bacx MOA ¢¢21
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
Environmental Services Division
825"L" Street, Room 502 · Anchorage, Alaska 99501· (907) 343-4744
Health Authority Approval Checklist
Leg~Descripd0n: Lot 31, Lakewood Hills Subd. ~3 P~cel I.D.:
A. VqELL DATA
Well ~pe private
Log present (Y~ yes
Total depth 147 ft.
Sanitary seal (Y/I',9 yes
If A, B, or C, attach ADEC letter. ADEC water system number
Date completed 9/14/93
Cased to 146 ft 7 irCasing height (above ground)
Wires properly protected (Y/N)
Date of test
Static water level
Well production
WATER SAMPLE RESULTS:
Coliform 0
Date of sample: 5/24/96
FROM WELL LOG AT INSPECTION
9/14/93 5/24/96
75 ft. 80 ft.
15 g.p.m. 6
B. SEPTIC/HOLDING TANK DATA
Nitrate 5.80 Other bacteria
Collected by: Chad Helgeson
Tank size3000 gal Number of Compartments 2 Cleanouts (Y/N)
N
~figh water alarm
Y Depression (Y/N) N
Pumper Rotor Rooter
Date installed 9/8/93
Foundation cleanout (Y/N)
Date ofPmnping. 5/28/96
C. ABSORPTION FIELD DATA
Date installed 9/8/93
Length 47 ft.
Soil rating ~or ft2/bdrm) 0.8
Width 2.5. ft. Gravel thickness below pipe
4 inches
yes
System type Deep trench
6 ft. Totaldepth 11.5 ft.
Effecfiveabsorpfionarea 564 sq.ftMonitoringTubepresent(Y/N). Y Depression over field (Y/N) N
Date of adequacy test 5/24/96 Results (Pass/Fail) Pass For 3 bedrooms
Fluid depth in absorption field before test (in.); 0 in. immediatelyafter590 gal. wateradded (in.): 4 in.
Fluiddepth 0 (ins.) Minutes later: 20 rain Absorption rate = 7104 _g.p.d.
Peroxide treatment (past 12 months) (Y/N) N If yes, give date
D. I,IFF STATION Not Applicable
Date ins~/led
Manhole/Access (Y/N)
High water alarm level at*
Cycles tested
E. SEPARATION DISTANCES
Size in gallons
"Pump on" level at*
*Damm
"Pump off' level at*
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic/holding tank on lot 118 fL. ; On adjacent lots 120
Absorption field on lot 110 ft:. ; On adjacent lots 130
Public sewer main 100+ f'c. Public sewer manhole/cleanout 100+
Sewer/septic service line 100+ Et:. Lift station Not: ApplJ_cab]_e
SEPARA'HON DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Buildinglbundation 15 £t:. Propertyline 20+ t~t:. Absorption field 3 1St:.
Water main/service line Surface wateffdrainage 101 fi:. Wells on adjacent lots
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Btdlding foundation 18 ft:. Property Line 10+ fi:Water main/service line
S,fface water 104 flz. Driveway, parking/vehicle storage area 24
Curtain drain 100+ fi:. Wells on adjacent lots 101
1~ NGINLER S CERTIFICATION .:,'
I certify that 1 hq~e determined thrufi/~ld inspections and review ofMunicip'a..l rec~l~Ftthe
in conformance/~it~OA I~!~A gu~J~lines in effect on this date ;' ['~?/,.t,.t
z/ -- -- t // ' '9,, %,'"..
..- ..
m l eo 049
Date of Payment ~/g//r~7 ~'
Rev. 8/95 DSS: haa.wk.doc
Waiver Fee $
Date of Payment
Receipt Number
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AU'T'HORITY
APPROVAL FOF~ A SINGLE FAMILY DWELLING
Parcel I.D. # ¢'/1~-\%~/- IR
1. GENERAL INFORI~ATION
Complete regal description
Location (site address or directions)
Property owner
Mailing address
7500 Upper O'Ma~le~ Road
Th6 Blomfield Co. Day phone 562-2766
560 E. 34th Ave. Suite I05 Anchorage, AK 99503
Lending agency
Mailing address
Agent
Address
Day phone
Day phone
Unless otherwise requested, HAA will be held for pickup.
NU~.IBER OF BEDROOMS:
TYPE OF WATER SUPPLY:
NOTE:
XXX
Individual well
Community well
Public water
ff community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
NOTE:
XXX
Public sewer
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 tRey. 1/91) Front MOA ~21
5. STATEMENT OF INSPECTION BY.ENGINEER
'17034 Eagle River Loop Road/~
Address Eagle River,
Engineer's signature
/×/
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/orwastewater disposal system is safe, functional and adequate for the number of bedrooms
and typeofstructureindicated herein. I furtherverifythat based on the information obtained from
the Municipality of Anchorage files and from my inves_tLgation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance wit.~b_h ~1 Municipal and State codes
ordinances, and regulations in effect on the date of this ~.spbction//
Name of Firm S ~~--'ff. INC- /// /Phone
2
Date .-~
6. DHHS SIGNATURE
Approved for
bedrooms.
Disapproved.
/~. Conditional approval for ~ bedrooms, with the following stipulations:
Additional Comments ~ote, mh¢ ~¢~ ¢~ ~h%~ ~~ m¢¢~ ~t-4~
State and Municipal Codes. There are nitrates present. It is
~~that a p~iodic tcsting-bc pcrfcrmed %~-~ure ~ells
is 5.98 mB/1. EPA
Date /
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineeFs work.
72-025 (Rev. 1/91) Back MOA /~21
Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: lOT' $1 /_~/,<;~ H/L.L_5 ~]~Parcel I.D.
A. Well Data
Well type .~ I ( / A"i-~~-
Log present (~N)
If A, B, or C, attach ADEC letter. ADEC water system number Date completed ~J/l~-/ ~/3 Driller
Total depth 1~9 (
Sanitary seal (~)N) T"~-5-
Date Of test
Static water level
Well flow
Pump level1
Cased to IZ/~,' ?/f
FROM WELL LOG
SEPARATION DISTANCES FROM WELL TO:
Septic/,b~l~q~tank on lot
Absorption field on lot /
Public sewer main ~'/Y''-
Sewer service line
Casing height
Wires properly protected (Y/N)
g.p.m.
; On adjacent lots
; On adjacent lots
Public sewer manhole/cleanout
Petroleum tank
AT INSPECTION m
'-r
WATER SAMPLE RESULTS:
Coliform 0
Date of sample:
Nitrate
Collected by:
Other bacteria
B. SEPTIC/H~4~TANK DATA
Date installed ~/
Cleanouts~N)
High water alarm (Y~-~
Date of pumping ~EM
Tank size /0/.)O ~A C_ Compartments
Foundation cleanout(~N) ~.,r Depression (Y~])
Alarm tested (Y/N) -
Pumper · /CY/~
SEPARATION DISTANCES FROM SEPTIC/NG~DT~-,,,~ TANK TO:
Well(s) on lot /~ ~>~ On adjacent lots /'~ ~
Foundation
To property line I'J
Surlace water/drainage
72-026 (3/93)* Front
Absorption field ~'~
1o1.$'
Water main/service line
CONTINUED ON BACK PAGE
SEPARATION DISTANC~ATION TO:
Well on~t~ On adjacent lots
D.'~ABS;RPTION FIELD DATA
Date installed ¢'/~/~..7 Soil rating (GPD/FF)
C. LIFT STATION /~o~JC~. [~ESE~7~ ~
Date installed Manufacturer .
Size in gallons Manhole/Access (Y/N) ~
.... ~el at
Vent (Y/N) "Pump on level at ~'
High water alarm level ~"~t~s tested
Meets MOA electrical codes (Y/N)
Surface water
Length z~g' Width
Total absorption area .~'~,~
Date of adequacy test ^.)Ek/
Water level in absorPtion field before test
Peroxide treatment (past 12 months) (Y8
(_.~. (~ Systemtype DE£P ~kK£/,.)c_k/
~: ,% / Gravel thinness ~ / Total depth / ~ *
Cleanout present'N) ~E% ~ ~epressbn over field (Y~ ~ o
Resu,s (pas~fa,I) *~ for ~ CT~ ~*~) Beer. ms
~//~ A~er test ~/A
~ O If yes, give date ~/~
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot ~OO/+
To building foundation
On adjacent lots P- 0
Surface water / I0 ~
On adjacent lots / OO / Property line /O
To existing or abandoned system on lot ¢,Jok)E.
Cutbank ~O¢.~E ~o,¢_e%E/,JF' Water main/service line
Driveway, parking/vehicle storage area .¢
Curtain drain ~Jo/..JE ~,,4Uoc. O/~a
E. ENGINEER'S CERTIFICATION
,cerfifythatlhavechecke_~d, verified,
~,u ........ ~4 ~gle River o
EngineeCs N~gl~
H~ Fee $
Date of Payment
Receipt Number
Waiver Fee $
Date of Payment
Receipt Number
Commercial Testing & Engineering Co.
Environmental Laborstory Services
LABORATORY ANALYSIS REPORT
CT&E l.[ef.# 94.1247-11
Clleatt 8ample ID 131 LAKEWOOD 1 Ill ,I ,S S/D ~f3
Matrix WATER
(21ientN~'trrte S & S ENrBINEERTN(i'
Ordered By R. 8HAFEK
project Name
PWSID
WOt~ Order '/6883
Printed [)ate 03/2.8/94 ¢)..'.' 12:10 ]u's,
Collected r.}at¢ 03/23/94 ~./j 18:48 hfs,
Rx:ccivcdI~ate 03/24/94 (.c_~ 09:30 hrs.
'l'ect'ml cal Director sTEPHEN C, 151) '.'
QC Allowa[,le Ext. Ampi
I'armnctcr Rcaul~:~ Qual Unit;s Med:~od l.mii[~ Bate Dare [nit
--~'"'~rTa~'~'~ ................. 5,98 mg/L EPA 353,2/30(;.0 i0 03/25/94 I.LH
* See 8p,;¢J. al lnstmcti, on.~ gbovc I.;A= [Jp.a,,'aih~ble
** SccS~nplel{em~k~ove, · '- i , . ' L'r=Less~um.
D = 8~on~'y ~ll~ion.
5633 B Street, Anchorage, AK 99518-1600 -- Tel: (907) 562-2343 Fax: (9071 ~61.5301 ......................
~NVIRONMENTAL FACILITIES IN A~SKA, COLORADO, ~LORID;',, Ii .t.tNO~8, MARY~ND, NEW J~.RSEY, ONTO, UTAH. W~ST VIRGINIA