Loading...
HomeMy WebLinkAboutBINGMAN TR B-1 Municipality of Anchorage Page ! of _-~ DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: S,0U' q, ol o~ ~ PID Number: O I Name: ~C ~ ~. ~ L Wastewater System: ~New ~ Upgrade Address: ~ ~. ~ ~ O ~ ~ ~ ~/ ABSORPTION FIELD Phone: ~ No. of Bedrooms: ~ ~ Deep Trench ~ Shallow Trench ~ Bed ~ Mound ~ Other LEGAL DESCRIPTION so, Rating: Total Depth from original grade: Lot: Block: Subdiv~ion: Depth to pipe bosom from original grade: Gravel depth beneath pipe Township: ~ Ranger ~ Section: Fill added above original grade: Gravel length: I I WELL: ~ New ~ Upgrade erave~ width: Number of lines: Distance belden lines: Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: Driller: ~-- ~ ~te~/l~/~Drilled:~ Staticj~oWater Level:Ft.Installer:c J ~ Date installed: Yield: IPump Set at: Icasing Height AbOve Gr0und: TANK SEPARATION DISTANCES ~s,,tic ~ Ho~ing ~ S.~.~.P. TO Septic Absorption Lift Holding Public/Private Manufacturer: Capacity in gallons: From Tank Field Station Tank Sewer Lines ~H T~ [~ Walk ~[ ~' [ ~ ~/~ ~/~ 7~ Material: ~ ~ Number of Com~ments: Suflace Water ~ O N ~ LIFT STATION LineL°t ~ ~ ~ ~ ~ _ Sizein gallons:I~ Manufacturer: Foundation I~ ~'~ ~ __ "Pump on" level at: I "Pump off" level at: ~ High water alarm at: CuAainDrain ~l 0 ~ ~ Pump Make & Model~ Electrical Inspections peflormed by: Remarks: BENCH MARK Location and Description: A~um~ Elevation: ENGINEER'S SEAL Inspections performed by: ~~ Dates: ls, ~o~* Depa~ment of Health and Human Se~ices approval Reviewed and approved by: ~J~~ ~ Date: ~-~- 72-013 (Rev. 9/91) MOA 25 N 5O Y5 ££4LE; /" -- 50 ?T, .8 100 /25 150 TRENCH LOCATION ® ,'STEI~ GAL FT FOTAL DEPTH  OCKDEPTH 5 FT OVER ~oO TOBBEN SPURKLAND P,E. 203 W 15TH. AVENUE ANCH. AK. 9950! (907) 279-$9~6 II TRACT B1, BINCMAN SJD MICHAEL P. SEIDL SEPTIC SYSTEM AS BUILT OA [E: JUNE 9, 1999 SHEET: 2/5 G£1D: 2224 PERMIT// SW990026 PID Ol 1-112-41 BINGWBI2. DWG REPLACEWENT TRENCH '~.-~n % No, cE-eaas S~ondord ~re~ch~ SO' L on9 ~' Deep ~O' Se~er rock 4' Cover ~0 1 ~ 0 O: 0 l Monlto~ / E~J. 21~' // 81,2 ~ 81,2 / Effeofive ND SCALE AS BUILT TOSSEN SPURKLAND P,E, ~0~ B-X BZ~A~ SEPTIC SYSTEM SCHEMATIC 203 W15th Ave Anchora9e Ak 99501 SAND LA~E ROAD SATE: JUNE 9, ~999 WICHAEL P. SE/DL SHEET, PENWI~ ~ ?W99002~ PARCEL ID ~ 01 ~- ~ ~2-4~ BIMOWB13, DW? (907) 349-8535 ANCHORAGE, ALASKA 99511 DRILLING LOG SiZe o! casing~fJL----Depth of Hole,, ~ 6 ! ' Of.fOrmations o _. 2 TO.,,, 5 8 TO 20 ..... 2 0 TO_.1 5 9 !?a TO ~In feet Cased to-.? 6 n.. -~ n feet Fh~sh o! well (check one) open end ( X (minute) for I --. hours with penetrated, size of material, color and hardness RE. CEIVED Municipality ot Anchorage Dept. Health & Hutnan Se,-v;ce& ); .2.49 TO a0g WAT_ER~ARING GRAVEL: $__LIGHTL¥ .SANDY. ,TO TO ..... _TO TO- ..... CONTRACTOR I~ 39Vd ONI 'gNIqgI~JG ¢,1 N LBF~Eg~ ,ak_-. :88 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 995~9-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: Mar 08, 1999 Expiration Date: Mar 07, 2000 Permit Number: SW990026 Legal Description: BINGMAN TR B-1 Design Engineer: 0007 Tobben Spurkland, PE Owner Name: MICHAEL P. SEIDL Owner Address: P.O. BOX 103534 ANCHORAGE , AK 99510- Parcel ID: 011-112-41 Site Address: 007745 SAND LAKE RD Lot Size: 49333 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field ~] SepticTank [] Holding Tank [~] Privy [] Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Issued By: Date: ~-- ~:~- ~,~ 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN TRACT B-1 BINGMAN S/D MICHAEL P. SEIDL Municipality of Anchorage Department of Health and Social Services 820 1 Street Anchorage, Alaska 99501 February 24, 1999 We are submitting an application for the installation of a well and septic system for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the well and septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: No Ground Water or Impervious Layer to 16 ft. Use Standard Trench Soil Rating. From Testhole 02/18/99 <1 min/in = 1.2 gal per sq.ft/day No. of Bedrooms 4 Required Area per Bedroom: 150/1.2 = 125 sq.ft. Total area required: 125 x 4 = 500 sqft Testhole depth 16 feet Bottom Rock At 9 feet Top Rock At 4 feet Rock Depth 5 feet Total Trench Length 500 / 10 = 50 ft. SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 50 FT TOTAL WIDTH 2 FT TOTAL DEPTH 9 FT ROCK DEPTH 5 FT COVER 4 FT SEPTIC TANK 1250 GAL The installation of this septic system will not prevent wells from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. RI BI ~ B,~ I ~ I ~ TB~IEN SPURKL~N~ ~,~ '~ ~FESS %~~ SCALE; ~" = ~00 FT, TOBBEN SPURKLAND P.E. TRACT B1, BINGMAN S/D SEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE DATE: FEB, 15, 1999 ANCH. AK. 99501 MICHAEL P. SEIDL SHEET: 1/3 GRID: 2224 PERMIT ~ SW9900XX PID 015 BINOMB21.DWO 25 iol £C~L£: 1~ = 55 FT, ?r I FOTAL DEPTH ~OCKDEPTH 5 FT OVER ~oO I ?O££EN SPURKLAND P.E. 203 W 151-/-/. AVENUE ANCH. AK. 9950i (907) 279-39i6 PERMIT ~zSP/9900XX II TRACT BL BINGMAN $/D II SEPTIC SYSTEM DESIGN DATE: FEB. 15, 7999 SHEEt' 2/3 GRID: 2224 PID 015 BINGM$IZ. DWG ~.~ N\x- 2' 50' ~0' Sewer rock 4~ Cover PR/MARY TRENCH ~ i25~ 90~ SepS'c ~onk NO SCALE (Hon/ t or C~eonout5 4' Cover S,O F? oF Sep?/c ~ock Effective 1250 9ol, septic N~ TBgBEN SPURKLAND P,E, ~ ~-] ~I~~ S~P SEPTIC SYSTEM SCHEMATIC 203 W15%h ave SAND LAKE ROAD DATE: FEB. 15, 1999 Anchorage ~k 99501 W/OHAEL a SE/DL S~EET: ~7~-~915 PENW/~ ~ SW9900XX PANCEL /D ~ XX PERFORMED FOR: Muni :il:aiRy of Anchorage DEPARTMENT OF ,.IEALTH & HUMAN SERVICES 825 "L" Street, Alu..'.horage, Alaska 99502-0650 SOILS LOG- PERCOLATION TEST LEGAl. DESCRIPTION: 3 6 7 Township, Range, Section: SLOPE SITE PLAN 10 11 12 13 14 15 16 17 18 19 2O WAS GROUND WATER ENCOUNTERED? S L IF YES. AT WHAT O DEPTH? p E Gross Net Depth to Net I~eading [~ate Time Time Water Drop ,, 'g,.,.- ? Del. tit lo Waler Alter _/ . Mo.qitoring? ~ Date: DISCLAIMER: C~r~undwater Past and future presence ' ?rom these obs~vat~ons. ~. PERFORMED BY'. !: ~ ....... I '~ ACCORDANCE WiTH ALL STATE AND MUNICIPAL GI.,,IL ELINES IN EFFECT ON THiS CALF. PERCOLATION RATE ~ I (minutes/inch) PERC HOLE DIAMETER T~ST RUN BETWEEN ~ FT AND °'~ FT c~nditions indicated are for the dates and/or depth of gro,,ndwater can not be shown only. predicted __ CERTIFY THAT THIS TEST WAS PERFORMED IN 72-008 (Rev. 4/85) 9 7 •6 : Municipality of Anchorage On-Site Water and Wastewater Program < WI (907) 343-7904 c .,,ly f,,,Y :„0 n a. Certificate of On-Site Systems Approval � • c., ,- / Parcel I.D. 011-112-41 Expiration Date: 0 ( A 1. GENERAL INFORMATION Complete legal description Bingman Tr B-1 Location (site address) 7745 Sand Lake Road Current Property owner(s) Michael Seidl Alaska Community Property Trust Day phone Mailing address 7745 Sand Lake Rd. Anchorage, AK 99502 Real Estate Agent Day phone 2. TYPE OF DWELLING: D Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: • ) Received by:` . ,' 4 Date: 1...*(Q2_1 hipfr COSA to be released to the engineer,unless • erwise requ ste by the engineer. COSA Fee $ 524 Waiver Fee $ Date of Payment 5l74/I Date of Payment Receipt Number ()Wag 62 Receipt Number COSA# 05Cl31/C0 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone . Date 5/4/2018 ,..�v .OFA•IS,, 6. DSD SIGNATURE ••�•ri 4h. � ••�- xSystem #1 Approved for bedrooms ..Steven R. Pannone: / I 6 1.• CE-8149 �� System #2 Approved for bedrooms 61.- CE— Disapproved lel;\"I�4+- Conditional approval for bedrooms, with the following stipulations: ,v ,' aY� G7-).--_---e' Original Certificate Date: �---- (7- I? The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheeti: ,. If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: Bingman Tr B-1 Parcel ID:01 1-1 12-41 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 5/13/1999 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 260 ft. Cased to 260 ft. Casing height(above ground) 12+ in. FROM WELL LOG AT INSPECTION Date of test 5/13/1999 3/13/2018 Static water level ,120 ft153.1 ft. Well production 3 l g.p.m. 2.7 g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate Nn mg/L Arsenic ug/L Date of sample: 4/27/2018 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 5/26/1999 Tank size 1250 gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N/A Date of pumping 7/10/2017 Pumper A+ Home Services C. ABSORPTION FIELD DATA Date installed 5/26/1999 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 GPD/SF System type Deep Trench Length 50 ft. Width 2 ft. Gravel below pipe 5 ft. Total depth 9 ft. Eff. absorption area 500 ft2 Monitoring tube _ Depression over field N Date of adequacy test 3/13/2018 Results(Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 21 in. Water adde ?; gal. New depth 25 in. Elapsed Time: 120 min. Final fluid depth 21 in. Absorption rate >_ 45/41fVW g.p.d. N Any rejuvenation treatment (past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100+ Absorption field on lot 100+ On adjacent lots 100+ Public sewer main 75+ Public sewer manhole/cleanout 100+ Sewer/septic service line 25+ Holding tank 100+ Animal containment areas 50+ Manure/animal excrete storage areas 100+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5+ Absorption field 5+ Water main 10+ Water service line 10+ Surface water 100+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water main 10+ Water Service line 10+ Surface water 100+ Driveway, parking/vehicle storage 10+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS G. ENGINEER'S CERTIFICATION +� OF AL,4 is,l� I certify that / have determined through field inspections and "gr. •• �"-- 941 review of Municipal records that the above systems are in 0*: - ! . i\ •.*Y0 conformance with MOA COSA guidelines in effect on this date. %••••`•' W. ; ••• 0 Engineer's Printed Name Steven Pannone ,�••..Steven lt Panriorie Date 5/4/2018 �+kgs• CE-8149 ,� i COSA canary sheet_2-6-15.doc MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT I. . 907-343-7904 On-Site Water and Wastewater Section Fax:343-7997 www.muni.org/onsite Arsenic Advisory Certificate of On-Site Systems Approval # OSC181190 Subdivision: Bingman, Tr B-1 A water sample revealed an arsenic concentration of 17.7 micrograms per liter (ug/L). The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. information on arsenic is available from the On-Site Water and Wastewater Program website (www.muni.org/onsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On-Site Systems Approval. Mailing Address: P. O. Box 196650*Anchorage,Alaska 99519-6650 *www.muni.org TRACT A 8198R N89°58'49"W 250.00 40 } m mc B I Q N ca Nw a) CC w a co Y N V o J w -0 TRACT B-1 121 co ca J Septic vent Septic vents I` TRACT B-2 0) ie— (f)j Oifir o� `���N Co 2 0 • IIIII —.sal 113.3 ,� ti� 17.1 ^' 15.5 �' ct "': '=h: :?ia� ?sd 2 112 Slory Z I a r;.:,.ks•t+.. Asphalt •:,r:.:rT�.• Frame �r F— r i,,a..r ,= :.r :` 10.5 74 c..f?�,"r`' is r`';