DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES) DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-0650 0 Telephone: 343-4744
On -Site Wastewater Disposal System andjor Well Inspection p Report
Permit Number: SW9801 52
Pib Number. 015-271-74
Name:
The Petersen Group
Wastew4ter System: bPNew ❑ Upgrade
Address:
3820 Lake Otis, Suite 204
ABSORPTION FIELD
Phone:
562-1170
No. of Bedrooms:
Five
❑Deep Trencch hallow Trench ❑ Bed ❑ Mound ❑ Other
LEGAL DESCRIPTION
Soil Rating:
Total Depth from original grade:
• 1.7i GPD/Sq. Ft.
^V1 g, s
Lot: Bloc ' ��� ��SubLLdivision:
tl//�I\Tr�f
Depth to pipe bottom from original grade:
AVG. •7 Ft.
Gravel depth beneath pipe ��
4:2.
Township: Range: Section:
Fill added above original grade: ,
Ft.
Gravel length:
A'�7 • L• 7 Ft.
Ft.
•
WELL: - C1ew Upgrade
Gravel width:
Number of lines: Distance between lines:
Classification (Private, A,B,C): Total
,{Depth: Cased To:
►rJ V ��/ �L'4'r
7 Ft.
Total absorptio, area:
G'i ( Ft.
Pipe material: 46TH i5 -3o34,
Ft. FL
Drill Date Drilled: Static water Level:
116 'prfi
SO. Ft.
Installer. l
Date installed:,.
Yield: Pump Set at:
> /0
Casing Height Above Ground:
TANK
GPM Ft
IFc.
SEPARATION DISTANCES
❑ Septic ❑ Holding OfT.E.P.
To
From
Septic
Tank
Absorption
Litt
Holding
ate
Manufacturer.
Capacity in gallons:
Field
Station
Tank
Sewer lines
Tan2
000
Welt,
N i
_ /r?Co
N ,
—l29
��'
��
,
7�
Material:
Steel
Number of Compartments:
Two & L.S.
Watters
i50'
} lya'
.�-
-�-'
> 150'
LIFT STATION
Lotw
Line
t t
2d
�r t
77
-
r• ,
i7
Size in gallons:
� �-+oo
Manufacturer:
May` r/14K aKii1Go ,rs
Foundation
22 '
ti /_7 '
_
f
"Pump on" level at:.
"Pump off" level at:
High water alarm at:
Curtain
Orain
N
—
Pump Make & Modbl
Electrical Inspections performed by:
L L 144:1
Remarks:
BENCH MARK
Location and Description:
Assumed Elevation:
ENGINEER'S SEAL
Aar
rq�, .
Inspections performed by:,, -Dates: 1 st &/S
If
♦ejeaeeoe• e°OLVVAP ee° •�
2nd !3-
0 0 0 0 • .e °�
Department of Health and Human Services aproval
�0�� •• ° ° • eQy�-=
Reviewed and approved by: Date: l Z'
° • ° ° . ° °
Permit No. SW9$01 52
Page 2 of 4
Municipality of Anchorages
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 0_9519-6650 a Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: Lot 3, Blacktree Subd. PID No.: 015-271-74
' 1
A B
SP1 29.2 47.3
MH 42.8 57.8
M1 96.4 89.8
M2 95.2 73.0
M3 119.7 98.0
Iwo
e
T3�•^ ......
MOMEL �oo om oo oseo o. a oo oo([ppys��.�.e
.E.ANDERSON
p!
° �-
W
5 Bedroom
House
B jra r '
J b b
•b �
w4o-1
SPI
2,000 5a ,.S
PLAN AS -BLT S.T.E.P
P2
1" = 20' Mx ,
TH A
37'
x 5' W
MT2 ab so ption trench
�test pit
�ahsorption
6 ' x 5'W trench
T1
LEGEND
P1 Septic Pump, compartment 1
P2 n n of 2
Clean Out
T Monitor Tube
40
O
. O
A B
SP1 29.2 47.3
MH 42.8 57.8
M1 96.4 89.8
M2 95.2 73.0
M3 119.7 98.0
Iwo
e
T3�•^ ......
MOMEL �oo om oo oseo o. a oo oo([ppys��.�.e
.E.ANDERSON
p!
° �-
W
5 Bedroom
House
B jra r '
J b b
•b �
w4o-1
SPI
2,000 5a ,.S
PLAN AS -BLT S.T.E.P
P2
1" = 20' Mx ,
TH A
37'
x 5' W
MT2 ab so ption trench
�test pit
�ahsorption
6 ' x 5'W trench
T1
LEGEND
P1 Septic Pump, compartment 1
P2 n n of 2
Clean Out
T Monitor Tube
Permit No. SW9801 52
Page 4 of 4
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 a Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: Lot 3, Blacktree Subdivision PID No.: 019-271-74
10' T E. ESMT.
r— — — — — — — — — — — — — — — — —
I
I o
I
WELL
I �
I
I
I
U>
L'i I
wI
d
�I
1 "=50'
I
_ _______ 20' 30'
W
V)
Z I
O
N
of Z I
I 'J
MICHIGAN
4BR — —
64.5' EAST
AVENUE
house 69.2. 20.00'
�e 2,000 gal.
S.T. E.P.
I5 W absorption
-r trenches
MT`
e
u�
N
N
e oil • • e,� e�,o�e e e .
Dose See ew. ".9
LE. NNEd�:
4301-E •'rA
•sees•°
4
Permit No. SW9801 52
Page 3 of 4
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196660 * Anchorage, Alaska 99519-6660 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
4
Legal Description: Lot 3, Blacktree Subd. PID No.: 015-271-74
j C
Ma
geotextile fabric
,o 00
•� septic �• • o. rock
bo 4�. o e•o�p �• o�� •
5' 62 LF x 5' w trench
0 _
105.9
geotextile fabric
eo
• • ,. e . .
.
septic ° ° rock
x 5 W trench
0 101i�
27
LEGEND
ELEVATION AS -BLT
1" = 1o'
SP1 Septic Pump, compartment 1_
SP 2 of a 1$ 2
C Clean Out
MT Monitor Tube
11
01r°1.
n o••
;o e e X 10 51
93.1
BOH
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: Darrell Black DATE PERFOR
LEGAL DESCRIPTION: LT 3, Blacktree S/D Township, Range, Section:
prp�y� SLOPE SITE PLAN
2 L_ N
3
4 0tion sYst�
sePtlC ab
s
5 � (� see � e AS_Built I �
t
FIE
8 e
g
C, •
12-
13-
14'-
273 14 o
15-
16 '
Jj
WAS GROUND WATER
ENCOUNTERED?
_S
IF YES. AT WHAT C
DEPTH? P
E
Depen b Wmw Akr
NWAK lq? ' Det
20 -{
I�JI PERCOLATION RATE < t (mmutevmch) PERC HOLE DIAMETER/'�
-TEST RUN BETWEEN � FT AND -7 FT
COMMENTS %�� /'"7�+SGA"—y -T:"' 0'i- ry `fir
Reading Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
jr :0
2•o
I r2,o
I r3
PERFORMED BY: 11 1 x
a' f • Y THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: IZ,/T If 6
72-008 (Rev. 4/85)
e Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650.
SOILS LOG — PERCOLATION TEST
PERFORMED -FOR: Darrell Black DATE PERF
LEGAL DESCRIPTION: LT 3, Blacktree S/D Township, Range, Section:
2-
3
3
4 /
s;
7 D
9-
10-
11
011 '
12-
13-
14-
15
2131415
16-
17-
18-
19-
20-
WAS
617181920
SLOPE
WAS GROUND WATER
ENCOUNTERED?
S
IF YES. AT WHAT L
0
DEPTH? P
E
Depth to Writ/ After
mum"? brit
SITE PLAN
PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN SFT AND 1 FT -�--r - I
COMMENTS / �j Y� /� , f �iL��t T 7�' Sor.+�//O'a . /� i �G� /� CAME. 1 j_ rjj0t C A10, T.
PERFORMED BN(. 1 FY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE z k b
72-008 (Rev. 4i85)
■■NEMEM
E.
EEE N
E • '
•
.
■.
MEMO
i
NEEMMENEME
■MiEMEEMEME
EnEEE
PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN SFT AND 1 FT -�--r - I
COMMENTS / �j Y� /� , f �iL��t T 7�' Sor.+�//O'a . /� i �G� /� CAME. 1 j_ rjj0t C A10, T.
PERFORMED BN(. 1 FY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE z k b
72-008 (Rev. 4i85)
9075638453 PARKWAY ATRIUM BUILG 103 P02 DEC 02 198 15:56
STATE OF ALASKA
DEPAF�IVIENT OF NATURAL RESOURCES
�y
DIVI$I,ON OF* MINING & WATER MGMT
LOCATION OF WELL�%1 I Q9a I_41!�OL s1 •C"9(' -v -7,l WATER WELL RECORD
BOROUGH
BUBOIVI$ION LOT BLOCK SMMN (TRS
a
SECTION TDVIINSNIP
RANGE MERIDIAN
ED
El
D
❑W
LOCATIONfSKETCH:
WELL OWNER:
I
DEPTHS MEASURED FRO casing top ❑ground surface
WELL DEPTH: DATE OF COMPLETION
Depth of hole: y/. ft:
Depth of casing:. AU tt; _ �I I
BQFiIEHOLE DATA.,Depth
Material Type and COlor From To
DEPTH TO STATIC WATER LEVEL;
ft belo 7 ? top of; casing ❑ ground surface
YU
R
METHOD OF DRILLING: air iotary ❑ cable tool
❑ other
USE OF WELL: Wdomestic E3 'irrigation ❑ monitor
-,,
725 supply :0 other
r►
r CASING STIC -.Ij ft. Diam: b in, to ft
Casing type: in. to ft
'^r *
Iz
WELL INTAKE 004IENING TYPE. open end ❑ $greened
97
❑ perforated ❑ open hole
Depths of openings: � to - ft
SCREEN TYPE- Mam: in.
Slot/Mesh Size: Lehgth: ft
GRAVEL PACK TYPE:
Volume used: Dbpth to top:
GROUT Type- I
Depth: from ft to ft
DEVELOPMENT METHOD:
Duration:
MurtiC�
19
it
PUMPING LEVEL AND YIELD:
C� ft after_' „- rrrs pumping �ii� gpm
HUrTI
Owe
Service PUMP INTAKE D�PTH: � � ft Horsepower: _
'rI"C;TtD UPON COMpLE'TION? 'Q YES ❑ NO
CONTRACTOR
TION:
REMARKS:
c2 PLEASE r0AIL WHITE; COPY OF LOG TO:
..-L�40 DNR/DIVil'SION OF MINING & WATER MOMT
ate 3601 C St, uite 800
OCHORAGE A . 99503-6935
Phone (307)269.8639; Fax (9071562-1384
I
MEMORANDUM
Date: December 4, 1998
To: Donna Mears, MoA/D,,H� qHS
From: Mike Anderson, P.E. r V `�
Subject: Lot 3, Black Tree Subdivision
Attached is the as -built and application for a Certificate of Health Authority Approval for Lot 3,
Black Tree Subdivision. As you may recall the system was redesigned on August 18, to allow for a
2,000 gallon STEP Tank and pressure system. The absorption trench was sized based on Testhole
No. 4 which indicated a percolation rate of 3 minutes per inch. During construction of the trench
we found the soils in the area not consisten with the 3 minutes per inch and extended the trench
accordingly.
Our submittal on August 18 called for a trench 64' in length. The constructed trench is a composite
total of 99' in length to compensate for the slower percolation rate and inconsistent soils
encountered. The majority of the trench is in the 1.2 gallons per square foot per day soil. Some
however, is in the slower .6 gallons per square foot per day area. We are confident the constructed
absorption trench is more than capable of absorbing the septic effluent generated in the five
bedroom home.
- `j �?: 3 �
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE ? cu 'ncl I
DEPARTMENT OF HEALTH AND HUMAN SERVICES r
P.O. BOX 196650, 825 "L" STREET, ROOM 502'
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW980152
DESIGN ENGINEER:ANDERSON ENGINEERING
OWNER NAME:THE PETERSON GROUP,INC
OWNER ADDRESS:3820 LAKE OTIS PARKWAY,SUITE 204
ANCHORAGE AK. 99508
PARCEL ID:01527174
LEGAL DESCRIPTION:
BLACKTREE LT 3
LOT SIZE: 102366 (SQ. FT.)
NUMBER OF BEDROOMS: 5 THIS PERMIT: 5
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
DATE ISSUED: 6/04/98
EXPIRATION DATE: 6/04/99
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY: DATE:
ISSUED BY: �• d-� DATE:
'�' a clC,, C, vac
May 23, 1998
Municipality of Anchorage
Department of Heath & Human Services
825 "L" Street
Anchorage, AK 99502-0650
Subject: Lot 3, Black Tree Subdivision
Septic System Design
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 3, Black Tree Subdivision intends to construct a 5
bedroom home on the property. We are therefore applying for a permit to
construct a new well and septic system. The attached site plan and backup
documentation identify the size and location of the new septic system to
serve the home. The well location is also identified and the 100'
protective radius is shown. All septic systems serving adjacent lots or
within 200' of the new well are also shown.
Testholes were placed on the property in September of 1996 during the
subdivision phase. Silty gravel was found uniformly throughout the area
with percolation rates ranging between 16 and 30 minutes per inch. We
have designed a deep trench absorption system with 6' of effective depth.
The trench will be placed perpendicular to the slope, but at different
elevations. A flow splitter will be installed to assure equal dispersion of
the septic effluent. No groundwater was noted recently in Testhole No. 1 ,
but the trenches will be a total depth of 7.5' below existing ground as
further insurance against groundwater intrusion. Grading will be required
to add fill over the trenches to provide a minimum of 3' of cover and to
prevent surface water accumulation during periods of heavy runoff.
Similary, grading will be required should the reserve area ever be used to
prevent accumulations of water during snowmelt and runoff.
The surface of the lot slopes as shown on the site plan. The house will be
constructed on the knoll and the system will take advantage of the gravity
flow from the house.
Lot 3, Black Tree Subdivision
May 23, 1998
Page Two
If the system is constructed as designed the following statements apply:
1. The system, if constructed as designed, will have no adverse impact
on the wells in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact
on existing septic systems in the area or those to be constructed in
the future.
3. The system, if constructed as designed, will have no adverse
impact on reserved space, either surface or subsurface, on any lots
located in the area.
4. The system, if constructed as designed, will have no adverse impact
on drainage patterns in the area. The current drainage pattern w i I I
be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
M1C 1 Eh E.
4331 �E
/ L
Systems within 200' of new well
.are shown.
Lot 2
Lot 1 existing septic
absorption trent
�
I L71�I '
•`� � ' �� ion'/ _-�� g� i �� -
1 house,. - -�
N 7 \ i (.proposed) -
00 -Gal.
septic ,,t!Lnk y
-glow S litte
rpt iT reserve THz1 _ (2`') absor�ptlon trench
area i y = 54 LF x 61 E. D.
TS ® 1! '
IA
49—
t , k'
° ,,
° 433 n
,W NOTE:
This drawing is a conceptual
plan.' .The house and septic
system component locations may
SITEPLAN vary. Locations will be deter-
mined in the field.
SCALE 1" = 50'
SYSTEM PLAN
SCALE 1" = 20'
43331..
on
k
alve
Depth
(2)
LOT 3, BLACK TREE SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Five Bedroom Home Deep Trench System
Perc. Rate: 16 - 30 Min./Inch 1,500 Gallon Septic Tank
Application Rate: .6 GPD/SF 6' Drainfield Rock
5 Bedrooms X 150 GPD / .6 GPD/SF = 1,250 SF of Absorption Area
1,250 SF/12 SF/ LF of Trench = 104.25 LF Trench Length
Therefore: Construct a Deep Absorption Trench System With Two Laterals
Each 53' in Length with 6' of Drainfield Rock Beneath the Lateral.
Distribution Pipe in Trench Placed at 1.0' Below the Original Ground
Surface. Flow Splitter Required to Evenly Distribute Effluent to Each
3'-0"
I �
TYPICAL DEEP TRENCH SECTION
(NO SCALE) �a
NOTE: Grade Area Over Trench to Drain Away.
17
Minimum 3' of Cover over Septic System.
Minimum 4' Separation From Groundwater.
Minimum 10 Separation From Lot Line. ! i•
4 88i. YF
S' \ 4
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L•' Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
. ............
M10
HAELEANDIMSM
PERFORMED FOR: ---.1A,,,) yr -4
DATE PERFOR�I�
LEGAL DESCRIPTION: LT l / Township, Range, Section:
DE�/jp�o5Ls0 8` Cft- Sus SLOPE SITE PLAN
fS�
1
2 - N
5
6
7
8
9
10
11
• T Taw Ah,
•d .
s►A
M
12
'• �; ` SOME Ca►'1 QV G1...
13
14
�'.r.
Net
Time
Depth to
Water
15
Z L ; ZD
—
6V
16--
35'
/5
17
f
BV AA or-' 90'x
18
19
WAS GROUND WATER /� O
ENCOUNTERED? �y
IF YES, AT WHAT L
DEPTH? O
P
E
Depth to water -
Monitoring) ryO /VLD Dam f z9 9t'i
A
Reading
Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
t!F !
Z L ; ZD
—
6V
zh
35'
/5
535
s •
1205,
iS
L'$
S "
#S
T- : LD
/ S
SI u
20 -{ I L it
IL_ JI PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER
--� TEST RUN BETWEEN_ FT AND FT
COMMENTS �ESr�� � SbA�'F� J�iU(?�► 'TO -77"S77/4�+
PERFORMED BY: -- A, 1-14244A iRTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
T
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
�n4 J+.a.°,�,�Jry ��9n .�¢pqC ep'�• fF,i+fi:`M9
t a T»✓ 4
PERFORMED FOR: 4.477 CSN DATE PERFORMEk v,�s
LEGAL DESCRIPTION: �-OT !I Township, Range, Section:
P2oP051-'4 84ACJ4. SVQ , SLOPE SITE PLAN
�FE1 1 17 --
��2-
3-
4-
5-
6-
7
3 45
-7, ST*DL.—r
SM
5\J
9070M OF- 14o L4C
WAS GROUND WATER w 1 D
ENCOUNTERED? ' l+
S
IF YES, AT WHAT L
O
DEPTH?
P
E
neo to �� OL9 b(.
R
Reading Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
l 4 ZZ
: Js
--
51/9"
#Z-
/ 3a
/ S
577/4's
`/ S
75-
4%/s•
rj u
#y
z:vu
15
-7
v b„
/5
UPERCOLATION RATE (minutesnnch) PERC HOLE DIAMETER
T TEST RUN BETWEEN FT AND 9 FT
COMMENTS / EST /%Dl.G F11-' S'DAe'0 nW (;'L TD -7-
COMMENTS L
PERFORMED BY:A • ��� 1 THAT T IS TPT WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE.
7/ r
72-008 (Rev. 4/85)
/110
Municipality of Ancho
DEPARTMENT OF HEALTH & HUMAN SERVICES 9� .'4 9 dd s� ��
825 "L" Street, Anchorage, Alaska 99502-0650'. ° ° ° °
SOILS LOG — PERCOLATION TEST °' ° ..°° ° ° ° ° ° ' 4
MlI EL E �ANii� RG011
PERFORMED FOR: I�fFM �EGN DATE PER FOR�kd.'m ° Zj°
LEGAL DESCRIPTION: ��" %/ Township, Range, Section:
120f�05L'a 8f.14"UL, sV� . SLOPE SITE PLAN
2 o,
3 : +
e
4
4J, ;
5-
8-
9 -
lo
8 9 10
11
19
SM
50rACC GAA415L
I�o4vlC A]0. 3
swIG-p
o rz go LC
WAS GROUND WATER Al0
ENCOUNTERED? , y
S
IF YES, AT WHAT L
O
DEPTH?
P
E
090 to;MVa 0 L9 9L
20 -{
UPERCOLATION RATE /Z (mmuteslinch) PERC HOLE DIAMETER
T TEST RUN BETWEEN FT AND FT
COMMENTS ,FSTA'm jV1LC9-D'440 PWO& —M �7'CS '7-1N/+
S
PERFORMED BY: A' 1-1-424 iA 1 --1:1" ^- � OEM IFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE. 71�i,
72-008 (Rev. 4/85)
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 3, BLACK TREE SUBDIVISION
GENERAL:
1. The scope of this
project includes the furnishing and
installation of a new 1,500 gallon septic tank. It also
includes the construction
of two new 53' long by 3' wide by
6' effective depth
absorption trenches at the location
shown on the site
plan. The distribution piping must be
placed at 1.0' below
the ground surface. Grading will be
required over the trenches
to provide a minimum of 3.0' of
cover. In addition, a
flow splitter valve will be required to
assure effluent from
the septic tank flows evenly to each
trench.
2. Construction shall be in accordance with the approved site
plan, design drawings, Municipal Permit with any special
provisions or conditions, and all applicable State and
Municipal Wastewater Disposal Regulations.
3. The Contractor shall be
responsible
for
obtaining a I I
underground utility locates
and for the
layout
of the septic
system and verification of
the location
of all
lot lines.
4. Unless specifically agreed otherwise, the contractor shall
be responsible for final grading areas subsequently
depressed from soil settling. Property owner shall be
responsible for revegetation of affected areas unless
specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must
be certified by the Municipal Department of Health and
Human Services for system installations. Owners installing
their own systems must receive prior approval from D.H.H.S.
before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,500 gallon septic tank must be procured from an
approved source and installed outside the 100' protective
radius from the existing well.
Lot 3, Black Tree Subdivision
May 23, 1998
Page Two
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts
for pumping access.
3. The septic tank shall be sufficiently bedded to prevent
settling or shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of
12 inches above final grade.
5. Tanks installed without 4' of cover shall have a minimum of
2" of direct burial insulation.
6. A foundation cleanout shall be installed one to four feet
from the building foundation. Two cleanouts are required
between the tank and the drainfield.
7. Final grading over the tank shall be such that a positive
slope exists away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown
on the design. The bottom of the trench shall be within 2"
of level.
2. Distribution piping
must
be placed
level with perforations
down atop a level
bed of
drainfield
rock. Rock should then
be placed over the
pipe
to provide
a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between
the drainfield rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the
locations shown on the design. The portion below ground
must be perforated.
Lot 3, Black Tree Subdivision
May 23, 1998
Page Three
5. Contractor shall verify the septic tank and drainfield are a
minimum 100' away from any private water wells in the
area, 150' from a Class "C" Well or 200' from any community
well.
6. Direct bury insulation must be placed over the distribution
system if less than 3' of backfill depth is available. Finish
grade over the trench must be mounded to prevent
settlement or depressions.
7. Grade area surrounding the absorption trenches to drain
away.
8. A minimum 2' of accepting soil is required below the
drainfield rock for a 5' wide trench. Contractor shall verify
this condition prior to placement of the rock. All pockets of
unacceptable materials must be removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a Municipally approved
septic tank manufacturer.
2. The following pipe materials are approved for use in septic
system installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C.
(perforated and solid), ASTM F810 or H.D.P.E. (perforated,
but not solid) and ASTM D2662 or A.B.S. (perforated and
solid).
3. Insulation shall be at least 2" thick extruded direct burial
polystyrene (Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with
watertight couplings (Caulder, Fernco, or equal).
Lot 3, Black Tree Subdivision
May 23, 1998
Page Four
5. A permeable geotextile fabric (Typar, Mirafi or equal) must
be installed between the final drain rock layer and the
native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than
3% passing the #200 sieve.
INSPECTIONS:
A minimum of two inspections are required by Municipal
Ordinance. These inspections must be conducted under the
supervision of a professional engineer registered in the State
of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation
of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement
of the geotextile fabric, gravel, distribution piping,
standpipes, cleanouts and insulation. No backfill should be in
place at the time of inspection.
Contractor shall provide a copy of all field survey layout and
construction notes for use in preparing the certified as -built
of the completed system.
MEMORANDUM
DATE: August 18, 1998
TO: Donna Mears, MOA- DHHS
FROM: Mike Anderson, P.E. M Fa.-
SUBJECT: Lot 3, Black Tree Subdivision
RECEIVED
AUG 18 1998
Municipality of Anchorage
Dept. Health & Human Services
The placement of the house on Lot 3, Black Tree Subdivision will not allow gravity flow to the
absorption trench. A lift station and pressure system is therefore required for the treatment and
absorption of septic effluent. We have modified the design of the system for placement of a 2,000
gallon STEP Tank and a pressure distribution system. A copy of that design is attached for your
review. Please modify the design for the system on Lot 3 to allow the pressure system.
A testhole was placed at a higher elevation on the lot which revealed clean gravel materials with a
percolation rate of 3 minutes per inch. The absorption trench has been moved to this new location.
No groundwater was found in the testhole nor is any suspected over the monitoring period.
Results of the water monitoring will be forwarded with the as -built for the system.
BY DATE---___ CLIENT.
CHKD. BY DESCRIPTION
tr. o
SHEET--___ OF
JOB NO.
c 2,000 Gallon - -.-
STEP Tank
1.5" Distribution
Line
Monitor Tube
64' Long X 5' Wide X 4' Effective
Depth Absorption Tren h
Property Line
f� SYSTEM PLAN
( f`' NO SCALE
,i
EN 1S (10/78)
156' to
Property Line
LOT 35 BLACKTREE SUBDIVISION
DESIGN FACTORS:
Five Bedroom Home
Perc. Rate: 3 Min./Inch
Application Rate: 1.2 GPD/SF
SYSTEM REQUIREMENTS:
5' Wide Trench System
2,000 Gallon STEP Tank
4' Drainfield Rock
5 Bedrooms X 150 GPD / 1.2 GPD/SF = 625 SF of Absorption Area
625 SF/5 LF (Width) X .5 (Red. Factor) = 62.5 LF Trench Length
Therefore:
Construct a 5'
Wide
Absorption Trench System With One
Lateral 64'
in Length with
4' of
Drainfield Rock Beneath the Lateral.
Distribution
Pipe in Trench
Placed
5' Below Original Ground.
5'
� E
TYPICAL WIDE TRENCH SECTION
(NO SCALE)
NOTE: Grade Area Over Trench to Drain Away.
Minimum 3' of Cover over Septic System.
Minimum 10' Separation From Lot Line.
Minimum 4' Separation From Groundwater.
E
0 1t
/6
C1
w
7,1
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES r o
825 "L" Street, Anchorage, Alaska 99502-0650 f
SOILS LOG — PERCOLATION TEST F
PERFORMED FOR: Petersen Group DATE PERFORMi"�
LEGAL DESCRIPTION: Lot 3, Black Tree Township, Range, Section:
q SLOPE SITE PLAN
0: ff "F#
1
2-
3-
4 3 4 �
5 �.
�6 0
,♦ V
7 a
t '
8-
9-4 9
a
10-
11
0 11
C
12 p
U
13 ` Q.
14-
15-
16-
17
41516 17
18
19
Ale]
OL/SM
TESTHOLE No. 4
GW/GP
WAS GROUND WATER NO
Trace Silt ENCOUNTERED?
S
IF YES, AT WHAT L
0
DEPTH? P
E
Depth to Water After
monitoring? None Dam 8 /18 9 8
2
Bottom of Hole
11111■■A■1
MIMMMMEMHMMI
Depth to
Water
Net
Drop
T WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
DATE:
3Lt l8
!3' 8"
G LN"
MIMEMEENE
3 t I
2
MEMIMMEMEME
■EMMUMM■n
NEEMENE
MIMEMEEMOME
MEMO
IMMEM!
Reading Date Gross Net
Time Time
Depth to
Water
Net
Drop
T WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
DATE:
3Lt l8
!3' 8"
G LN"
I.
3 t I
2
20 1 I n
u PERCOLATION RATE 3 (minutes/inch) PERC HOLE DIAMETER 8
TEST RUN BETWEEN 6 FT AND 7 FT
COMMENTS Test Cavity Presoaked Prior to Test.
PERFORMED BY: /H 1 4-4'tl LA 1C
TIFY THAT T
IST
T WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
DATE:
&11,6
72-008 (Rev. 4/a5)
20 OSI 15 HHF - 9
W $109im
LTJ
200.00
u
z 150.00
OR
100.00
- 7 strife
EFFLUENT PUMPS
1/2H to 11/2 Hp
SINGLE-PHASE, 60HZ
115/230 VOLT
PC#2
O 9
05 HHF -
.4...
6 7-7--
YV 30.00 40 OSI 05 HH 2 st
:1y a
... ....... ... ........... ... .......... . . ......... ......... .. .............. .. ... ...... .. .....
.............. .. ...... .. . .. ... ........ ....... .. .. .........
......... ... ;.4 ....... ... ... ...
... . . ....... ...
..
al
........... .. ... ...
20 OSI 05 HHF - 5 stage
w 1/4" flowcontroller
................
0.00
0.00 5.00 10-00 15-00 20-00 25-00 30.00 35.00 40.00 45.00 30-00
27, 2-1
NET DISCHARGE, GPM
LLORENCZ'SYSTEMS,INC2826 COLONIAL ROAD ROSEBURG, OR 97470 (SM) 673-019
oil
sm,
aamm=
.4...
6 7-7--
YV 30.00 40 OSI 05 HH 2 st
:1y a
... ....... ... ........... ... .......... . . ......... ......... .. .............. .. ... ...... .. .....
.............. .. ...... .. . .. ... ........ ....... .. .. .........
......... ... ;.4 ....... ... ... ...
... . . ....... ...
..
al
........... .. ... ...
20 OSI 05 HHF - 5 stage
w 1/4" flowcontroller
................
0.00
0.00 5.00 10-00 15-00 20-00 25-00 30.00 35.00 40.00 45.00 30-00
27, 2-1
NET DISCHARGE, GPM
LLORENCZ'SYSTEMS,INC2826 COLONIAL ROAD ROSEBURG, OR 97470 (SM) 673-019
JOB _ �-O 7' �. ,J LAGtG
ANDERSON ENGINEERING
P.O. Box 240773 SHEET NO. OF Q�
ANCHORAGE, AK 99524 CALCULATED BY • DATE vQAd ! 4
(907) 563-7155
(907) 337-8855 CHECKED BY DATE
SCALE
. SEpn� ........ �avrp . - ........ .
. .............
. .............
LAIF
... .......... .....
........ ...
... ............... ...
C ��2"z•bfidg9S
TDk i�S g�
.... ....
6
Z���-`�� /3D
� +
s s
/F
z
�
L-........ S G
.. ... .
f
w,Z ...........
.
................... ............. ................... . .....-7............. .....�........... ............. ............... .............. ............. .............
.
......
.... IT ...........
....... .............. ..................
. ... ..................... .............. .............. ............... ............ .........................:.............. ...........
............. .............. :7
.............. .......... .............. 0
.... ............. ........... ... ........ .......
..... ................. .......... ............. .............. .............. . .
...... ................ ..................... .......... ................. ...............................
.. ........... .............. ........................................... ............. �* .............. .............. .............. : .................. ............. . ...
_............................�r.? .8 .. X ._ . . Z9
.... .... .
...,. .......... ... .................. .............. .............
.... ........ .....
..,...
G
. .
... .... ..........................
C ��2"z•bfidg9S
TDk i�S g�
t- .oiRZ.
Z���-`�� /3D
� +
-
j:SJ y.B7
..........................................................
...
.
...
........... ....... ;.
s.,. �} 1
. n
............ ..... -':...... .
.. -, ...
........ ............. ...,....... ...........
.......... .........
-......:
',.... .....:.. ;... T' 7. (:' ` !,1 4 _,rte ......... .......
rl:
c n
MUNICIPALITY OF ANCHORAGE
• '� DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On -Site Services Section cam
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D. # 01 5-271 -7ay HAA #_ >14�1 2)
1. GENERAL INFORMATION
Complete legal description Lot 3. Black Tree Subdivision
Location (site address or directions)
Property owner ' T -fie Petersen Group Day phone -962-1170
Mailing address. 3820 -Lake Otis Parkway, Suite 204 Anch. , AK 99508
Lending agency
Mailing address
Agent
Address
Day phone
' Day phone
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: Five (5 )
3. TYPE OF WATER SUPPLY:
Individual well xxx
Community well
Public water
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site xxx
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. "1) Front MOA #21
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm Anderson Engineering Phone 522-7773
Address
P.O. Box 240773 Anchor
AK 99524
Engineer's signature �c�c.z�� Date 12/4/98
6. DHH£ SIGNATURE _ 1I
v/ Approved for �y bedrooms.
Disapproved.
Conditional approval for
Additional Comments
By:
4UTW
bedrooms, with the following stipulations:
Date 12-498
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-M (Rev.1/91) Back MOA 821
e Municipality of Anchorage
RECEIVED
DEPARTMENT OF HEALTH & HUMAN SERVI&S 1999
Environmental Services Division Munr' akt�ta
825 L Street, Room 502 Anchorage, Alaska 995(pt(Ighj hh'' u��rriia��n ���p �a
Health Authority Approval Checklist
Legal Description: Lot IF Blank mrPP S ,hd i vi s i on Parcel I.D.: 01 5-271 -74
A. WELL DATA
Well type Private If A, B, or C, attach ADEC letter. ADEC water system number
Log present (Y/N) Y
Date completed 9/17/98
Total depth 241 ' Cased to
Sanitary seal (Y/N)
Date of test
Static water level
Well production
W4
241 '
FROM WELL LOG
9/17/98
147'
40 g.p.m.
WATER SAMPLE RESULTS:
Coliform
Date of. sample:
0
12/2/98
B. SEPTIC/HOLDING TANK DATA
Casing height (above ground)
Wires properly protected (Y/N)
AT INSPECTION
Y
2'
Nitrate Non Detect Other bacteria 0
Collected by:
MEA
Date installed 8 / 18 / 9 8 Tank size 2.0 0 0 Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout (Y/N) Y Depression (Y/N) N High water alarm (Y/N)
Date of Pumping New Pumper Construction
C. ABSORPTION FIELD DATA
Y
Date installed 8 /18 / 98 Soil rating (g.p.d./ft2 or ft2/bdrm) 1 .2 / . 6 System type 5 ' Wide Trench
Length 99, Width 5 ' Gravel thickness below pipe 4.2' Total depth 11 '
Effective absorption area 980` SF Monitoring Tube present (Y/N). Y Depression over field (Y/N) N
Date of adequacy test New Const. Results (Pass/Fail) pa s s For r i 370 bedrooms
Fluid depth in absorption field before test (in.); Immediately after gal. water added (in.):
Fluid depth (ins) Minutes later: Absorption rate = a.p.d.
Peroxide treatment (past 12 months) (Y/N) If yes, give date
72-026 (Rev. 3/96)*
D. LIFT STATION
Date installed 8/18198 Size in gallons 2.,000 sTFp
Manhole/Access (Y/N) Y "Pump on" level at* 45" "Pump off" level at* A5"
High water alarm level at*
47"
Cycles tested New . Construction
E. SEPARATION DISTANCES
*Datum Bottom of Tank
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic/holding tank on lot
Absorption field on lot
>100'
>100'
On adjacent lots >100,
On adjacent lots >100'
Public sewer main N/A Public sewer manhole/cleanout N/A
Sewer /septic service line >251 Lift station _>9>I a a I
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO:
Foundation >51 Property line >51 Absorption field > g; '
Water main/service line > 2 9_ Surface water/drainage >1001 Wells on adjacent lots > 1
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line > 10 ' Building foundation > 10 ' Water main/service line > 2 5 '
Surface water >100, Driveway, parking/vehicle storage area > F n ,
Curtain drain None on r.ot Wells on adjacent lots >100'
F. ENGINEER'S CERTIFICATION
I certify that I have determined thru field inspections and review of Municipal recur _>r Stems are
in conformance with MOA HAA guidelines in effect on this date.
Signature
Of °
Engineer's Name Mi _hael R- An rmr f
sn.n P E ."
12/4/98'�'°���
Dated'
° 4381-E
.°
Ilk
HAA Fee $ in, ice( `. Waiver Fee $
Date of Payment i QL-1- I �i Date of Payment
Receipt Number nl-A 1 ! k � _ Receipt Number
72-026 (Rev. 3/96)*