Loading...
HomeMy WebLinkAboutBIRCHWOOD SOUTH BLK 1 LT 2AOnsite File Birchwood South Block 1 Lot 2A #051-294-26 Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201380 PID Number: 051-294-26 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade Name Hoyt and Dougherty families ABSORPTION FIELD EJ Deep Trench El Wide Trench ❑Bed ❑Mound Site Address 18905 Monastery ❑Other Phone Number of Bedrooms Soil Rating Total depth from original grade 6 3 GPD/SF 6.6-6.9 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 6.2-6.4 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Birchwood South 1 2A Fill added above original grade 0.5 Ft. Gravel length 25 Ft. Township Range Section Gravel width 12 Ft. Beds: Number 3 of Lines Distance between lines 4 Ft. SEPARATION DISTANCES To Septic Absorption AWWT Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 300 Ft2 Ft. Well > 100' > 100' > 100' NA > 100' TANK ®❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer GREER Capacity 1500+1000 Gal. Surface Water > 100' > 100' > 100' NA Material Number of compartments Lot Line 6' > 10' > 10' NA NA PLASTIC 2 Foundation > 10' > 10' > 10' 1 NA AWWTS MODULE Capacity Remarks Q UAN I CS NA Gal. Alarm location in garage Electrical installed by DRS electric PIPE MATERIAL House to tank 3034 drainfield Tank to 3034 Installer JRs Septic Drainfield 3034 CO/MT3034 Inspector Curtis Townsend BENCH MARK (Assumed elevation) 100 ft Inspeection 151 6/21/2021 6/22/21 Location and description ction Yd 6/24/21 2nd 4'h 10/23/26 top of retaining wall ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp 0�C����� Conditional Approval: Date ��G.. • • • • • • q�,���� ii�) jti) j .. t •' s L. Tomesgnd' . �F. Date Z Z J Septic System A '�G�l( � Approved Date 5 �� cslF� PROFESSO Note: this approval does not include well permit requirements. DESIGN PARAMETERS BEDROOM: 6 (900 gpd) NATIVE SOIL PERCOLATION RATE: 10.4 MPI PROPOSED CAT II APPLICATION RATE: 3 GPD/SF AREA REQUIRED: 300 S.F. SYSTEM TYPE: BED DIMENSIONS OF BED 12' x 25' = 300 SF I WELL IS > 100' AWAY 6 BR Cn �z HOME F- J w >- U o' 0 w z0 ODry m m 144% APPROX TOP OF SLOPE, ELEV 506' SCOPE OF WORK 1. REMOVED (2) EXISTING STEEL SEPTIC TANKS. 2. PROVIDED (2) NEW SINGLE COMPARTMENT TANKS. THE UPSTREAM TANK WAS PROVIDED WITH A MINIMUM 20" 0 MANWAY RISER SERVING THE FIRST COMPARTMENT. THE DOWNSTREAM TANK WAS PROVIDED WITH A MINIMUM 20" 0 RISER TO HOUSE THE PUMPING EQUIPMENT IN THE SECOND COMPARTMENT. 3. EXCAVATED IN AREA OF EXISTING TRENCH TO 12.5' DEPTH, REPLACED WITH ERS AND A MINIMUM OF 2' OF FILTER SAND TO BELOW NEW EFFECTIVE DEPTH. BEYOND NEW BED IN AREA OF EXISTING TRENCH EXCAVATION WAS TO 12.5' DEPTH AND BACKFILLED WITH INSITU MATERIAL. — 4. ALL CONSTRUCTION WAS IN ACCORDANCE WITH ALL ~ REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL a- LJ CODE CHAPTERS 15.55 AND 15.65. V) 0 Of cD n II z 0 0 0 m CD - — — N w 0 z A / 100' PROTECTIVE WELL RADIUS / 37 FCO \ 1500 GAL TANK AREA PROTECTED 10' BY ROCKS�,�;� i B DCO1 BM w0 TH — ,F3 _MT3 M T2� s ,. IC04 s'- - ---- ---- CO3 's� CO2 15' EASEMENT _ _C05 C06 ------ MT1 I M T4 I 15' EASEMENT I — — -- — EDGE OF PAVEMENT Septic Record Drawings Prepared for HOYT and DOUGHERTY FAMILIES 18905 Monastery Rd Eagle River, Alaska 99577 BIRCHWOOD SOUTH BLOCK 1 LOT 2A OSP201380 CHANGE ORDER EKLUTNA ENGINEERING, LLC DATE: 2/12/2022 19162 MOUNTAIN ROAD DRAWN: CLT CHUGIAK, ALASKA 99567 SCALE: 1" = 20' (907) 406-1058 PID: 051-294-26 SHEET 2 OF 3 DCO2 1000 GAL TANK I QUANICS AEROCELL NS-750—AC TREATMENT MODULE I NS-750—AC CN u o MODULE FG 98.5 �o o� FG 98.2 n ::5u cn 97.1 1 N � OG 98.0 97.7 N N 92.4 1,000 G 92.0 1,500 G PLASTIC TANK 91.1 PLASTIC TANK SINGLE COMP. BOTTOM OF SAND 89.1 SINGLE COMP. 9 . ERS BELOW SAND TO A DEPTH OF 12.5' 6.5 GROUNDWATER IN OCT 2020 WAS FOUND AT 87.7' Septic Record Drawings Prepared for HOYT and DOUGHERTY FAMILIES .•�••F"�4�So�i 18905 Monastery Rd Eagle River, Alaska 99577 `'>:• '••!��i BIRCHWOOD SOUTH BLOCK 1 LOT 2A 49TH ��� ...., OSP201380 CHANGE ORDER � )" ' '`' � 0........ .......... EKLUTNA ENGINEERING, LLC "'" •" DATE: 2/12/2022 .CU TIS TOWNSENDc 19162 MOUNTAIN ROAD ���%' No. E 11904 DRAWN: CLT �sj,�., z CHUGIAK, ALASKA 99567 #jF 1Z/7 z.••' SCALE: 1 = 10' ♦� .... ��� (9 07) 406-1058 #1144�ESS� PID: 051-294-26 SHEET 3 OF 3 4%aI„��� MARK A B C STI 17'-8" 16'-5" ST2 14'-11 " 19'-5" DC01 17'-8" 24'-1 " ST3 21'-8" 25'-7" ST4 24'-1" 23'-6" DCO2 25'-0" 22'-0" TM1 21'-1" 20'-1" TM2 18'-8" 21 '-8" DC03 22'-0" 27'-5" MT1/C01 37'-2" 26'-6" CO2 35'-11 " 22'-0" CO3/MT2 33'-7" 17'-6" MT3/C04 14'-10" 25'-5" C05 18'-6" 29'-2" MT4/C06 22'-5" 32'-8" 10/13/21 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP201380 Work Type: Septic Upgrade Tax Code Number: 05129426000 Site Legal Address: BIRCHWOOD SOUTH BLK 1 LT 2A G:0754 Site Mailing Address: 18905 MONASTERY DR, Eagle River Owner: HOYT GORDON S & JUDITH C 50% & Design Engineer: EKLUTNA ENGINEERING, LLC* This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date ,»>Cnt 31 Q r Department Lot Size in Sq Ft: Total Bedrooms: 10/30/2020 10/30/2021 51150 ❑ Private Well ❑ Water Storage ITT All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: I 1. The MEA Letter of Non -objection shall be recorded with the Alaska Recorder's Office prior to inspection report Ii approval. 2. The distribution pipe shall enter at the midpoint of the absorption field in order to utilize the reduced vertical I separation to groundwater for an AWWTS. &+gym cu" n cis b1 se.� r-0 C,�Z` C -P-,11 C �� -� J0 u_Qe 20 VXX. oiJ W u e- -1� etc -I-i o �� d- , Received By: Date: Issued By: Date: �� �D �O 0 MUNICIPALITY F ANCHORAGE Development Services DepartmentPhone: 907-343-7904 " On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-294-26 Property owner(s) HOYT & DOUGHERTY Day phone Mailing address 18905 Monastery Road Eagle River AK 99577 Site address 18905 Monastery Road Eagle River AK 99577 Legal description (Sub'd., Block & Lot) BIRCHWOOD SOUTH BILK 1 LT 2A Legal description (Township, Range & Section) Lot Size 51,150 Sq. Ft. Number of Bedrooms 6 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (M all that apply) Absorption Field Fx_1 Initial ❑ Single Family (SF) ❑ (w/wo ADU) Septic Tank Q Upgrade 0 Duplex (D) 1-1Holding Tank ❑ Renewal ElMultiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Co4A. (Signature of property or autnorized agent) Permit/Rush Fees: 6 25r—OV119 Waiver Fees: Date of Payment: 0 Date of Payment: Receipt Number: O M % IJ Receipt Number: Permit No. Waiver No. GADevelopment Services\Building Safety\0n Site Water and WastewaterTormsUient FormsTermit Application.doc Eklutna Engineering, LLC curtistownsend@gmail.com June 24, 2021 Subject: Birchwood South Block 1 Lot 2A Upgrade Septic System Permit Request Narrative OSP 201380 change order In 1985, a 1250 gallon steel septic tank draining to a 55' x 6' wide x 3' effective depth trench was constructed. This system was sized for a 3 bedroom house. Sometime later, a 1000 gallon steel septic tank was also installed. This house is now considered a 6 bedroom house. The owners are experiencing issues with the system and would like to upgrade. Due to the small footprint, a Category II Advanced Wastewater Treatment System will be used. The two existing tanks will be removed and the existing trench will be rebuilt in place. The existing trench has an overall depth of 12'-6" from grade based on probing the monitor tube. During June 2021, it was discovered that sometime after 1985, this 3' effective depth trench had been modified and that 6" of effective depth sewer rock had been placed along either side of the trench to create a bed system. The approximate dimensions of this new bed are 12' width. We propose to reconstruct this system now as a 12'x 25' bed system having 6" effective depth. All old septic rock will be removed and ERS will be imported to replace removed material. A 2' sand layer will be provided below the 6" effective depth required for the bed system. 1. Soils. A 12' test hole was performed in the vicinity of this system in September 2020; and groundwater was monitored for at least seven days. Ground water was observed at a depth of 10'-10" below the surface in the test hole monitor tube during the month of October. Impermeable layers were not encountered in the test hole to 12'. 2. Soil Absorption System Design. See Sheet 1 of the design package. 3. Wells. This lot and the surrounding lots are served by a private water wells. There are no wells within 50' of the proposed septic system. The property to the south used to be served by its own well. This property has since been connected to ADEC water system AK2216198, Maranatha Water Utilities. The water well serving this utility is located to the west, greater than 200' away from the subject property. 4. Neighboring Wastewater systems. Immediate neighboring septic systems are all + 10' distant from property lines. 5. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 6. Topography: There are no slopes greater than 25% within 35' of the proposed drainfield. The proposed installation will not affect the future development of this or the surrounding lots. Sincerely, Curtis L. Townsend, P.E. DESIGN PARAMETERS BEDROOM: 6 (900 gpd) NATIVE SOIL PERCOLATION RATE: 10.4 MPI PROPOSED CAT II APPLICATION RATE: 3 GPD/SF AREA REQUIRED: 300 S.F. SYSTEM TYPE: BED DIMENSIONS OF BED 12' x 25' = 300 SF w z U f�- F Ld a w w w N0 o a - z � Fro 00 m� w Z n 100' PROTWIVE WELL RADIUS M -M _�- 6 BR I� HOME SCOPE OF WORK cc 1 1. REMOVE (2) EXISTING STEEL SEPTIC TANKS. 2. PROVIDE (2) NEW SINGLE COMPARTMENT TANKS. O THE. UPSTREAM TANK IS TO BE PROVIDED WITH NEW 1500 GAL A MINIMUM 20" 0 MANWAY RISER SERVING THE TANK, LOCATED FIRST COMPARTMENT. THE DOWNSTREAM TANK IS -� FOUNDATION TO BE PROVIDED WITH A MINIMUM 20" 0 RISER DCO S TO HOUSE THE PUMPING EQUIPMENT IN THE <1 S TANK, LOCATED SECOND COMPARTMENT. > 5' FROM 3. EXCAVATE IN AREA OF EXISTING TRENCH TO z I 12.5' DEPTH, REPLACE WITH ERS AND A MINIMUM cn J QUANICS OF 2' OF FILTER SAND TO BELOW NEW AEROCELL EFFECTIVE DEPTH. IN AREA OF NEW BED, MAX Fz w TREATMENT EXCAVATION DEPTH TO BE 8'-0". w m 4. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH u) ry ALL REQUIREMENTS SPECIFIED IN ANCHORAGE w MUNICIPAL CODE CHAPTERS 15.55 AND 15.65. z j7y :2i 00' PROTECTIVE — — 00 m[if 00 T44% w z A n APPROX �— SLOPE, TOP OF ELEV 506' 35 FCO HATCHED AREA SHOWS EXTENT OF)M�Tl J EXISTING TRENCH. EXCAVATE TO12.5' DEPTHAND BACKFILL WITHINSITU MATERIAL _ — — — — 15 EASEMENT_ s� 15' EASEMENT — EDGE OF PAVEMENT MONASTERY DRIVE Septic Permit Drawings Prepared for <1% HATCHED AREA TO BE EXCAVATED TO 12.5' DEPTH AND \ REBUILT TO NEW EFFECTIVE DEPTH. DIMENSIONS OF BED TO BE 12' x 25' x 6" EFFECTIVE HOYT and DOUGHERTY FAMILIES 18905 Monastery Rd Eagle River, Alaska 99577 BIRCHWOOD SOUTH BLOCK 1 LOT 2A OSP201380 CHANGE ORDER REQUEST EKLUTNA ENGINEERING, 19162 MOUNTAIN ROAD CHUGIAK, ALASKA 99567 (907) 406-1058 LLC I DATE: 6/24/2021 DRAWN: CLT SCALE: 1" = 30' PID: 051-294-26 SHEET 1 OF 2 AD, AW a ' : 49 rH 0 .......................................... ... i �. CURTISTOWNSEN[JAI ® �i� No. CE 11904 AV ® ...........•'IF:® M -1 N O J NEW 1500 GAL TANK, LOCATED > 10' FROM -� FOUNDATION DCO S NEW 1000 GAL <1 S TANK, LOCATED > 5' FROM PROPERTY LINE I QUANICS AEROCELL NS -750 -AC TH I TREATMENT MODULE Zs F s —I s T 00' PROTECTIVE — — WELL RADIUS\ HATCHED AREA TO BE EXCAVATED TO 12.5' DEPTH AND \ REBUILT TO NEW EFFECTIVE DEPTH. DIMENSIONS OF BED TO BE 12' x 25' x 6" EFFECTIVE HOYT and DOUGHERTY FAMILIES 18905 Monastery Rd Eagle River, Alaska 99577 BIRCHWOOD SOUTH BLOCK 1 LOT 2A OSP201380 CHANGE ORDER REQUEST EKLUTNA ENGINEERING, 19162 MOUNTAIN ROAD CHUGIAK, ALASKA 99567 (907) 406-1058 LLC I DATE: 6/24/2021 DRAWN: CLT SCALE: 1" = 30' PID: 051-294-26 SHEET 1 OF 2 AD, AW a ' : 49 rH 0 .......................................... ... i �. CURTISTOWNSEN[JAI ® �i� No. CE 11904 AV ® ...........•'IF:® Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201380, Rebecca Carroll, 10/30/20 TRACT A PLAT 82-422 N 89.50'00" W 165.00' MONASTERY DRIVE a 60' RIGHT-Oi -WAY LA AENDERD' SURVEY 4 MAPPING 299D S. BARNYARD CIR., WASILLA, AK 99654 DAYNA RUMFELT (! ffW)301-5177 NOTES 1. DIMENSIONS ARE RECORD PER PLAT 83-420. 2. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST. 3. THIS SURVEY DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THAT A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY DATA SHOWN BE USED TO ESTABLISH ANY FENCE, STRUCTURE OR ANY OTHER IMPROVEMENTS. 4. Q plo LOT 2E ALL VISIBLE ABOVE GROUND FEATURES OF THE EXISTING SEPTIC SYSTEM WERE LOCATED AT THE TIME OF SURVEY AND SHOWN HERE ON. 0 FOUND REBAR %S) SEPTIC VENT tJ WELL -13 2'f V TEST HOLE LEGEND CABLE PEDESTAL A LE, ELECTRIC PEDESTAL TELEPHONE PEDESTAL 4� OF Al% 1 FIREPLACE AMP, CANTILEVER . G2 ' 48TH • �' �l ..... Dayna M. RomfWt ■ ar No. LS 13322 � }� F�Fo ' VIP ` �� 5�� �tZZZ�� ASBUILT - NO CORNERS SET THIS DATE I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF LOT 2A, BLOCK 1, BIRCHWOOD SOUTH SUBDIVISION, PLAT NO. 83-420, ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE IMPROVEMENTS AS DEPICTED HEREON EXIST AS SHOWN IN RELATION TO THE PROPERTY LINES. EASEMENTS OF RECORD OTHER THAN THOSE SHOWN ON RECORDED PLAT No. 83-420 ARE NOT SHOWN HEREON UNLESS OTHERWISE NOTED. I DATE: 10/11/2020 1 FB: 2020-2 GRID: NW 754 1 DRAWN: DMR SCALE 1# = 50' 1 SCALE: 1" = 50' I FILE: 20-022AB BIRCH WOOD SOUTH SUBDIVISION cn LOT 2A o BL OCK I I o PLAT 83-420 0 I 4J Q c m Q D3.5' CD -3x 5' vy 2ND -STORY CANTILEVER Ev SHED I -gr EC ENT S6- l 2 -STORY W/ BASF .3' FAME DUPLEX 3.5' 28.7' "= 9.9'f �B,U (TH NC DE{{ I '� DECK ASPHALT j 7.8' SHED 16.7' DRIVEWAY 15' T&E EASEMENT — —}— — T 9K.1690, PG.398 15' T&E EASEMENT — S 89'50'00" E 165.00' MONASTERY DRIVE a 60' RIGHT-Oi -WAY LA AENDERD' SURVEY 4 MAPPING 299D S. BARNYARD CIR., WASILLA, AK 99654 DAYNA RUMFELT (! ffW)301-5177 NOTES 1. DIMENSIONS ARE RECORD PER PLAT 83-420. 2. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST. 3. THIS SURVEY DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THAT A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY DATA SHOWN BE USED TO ESTABLISH ANY FENCE, STRUCTURE OR ANY OTHER IMPROVEMENTS. 4. Q plo LOT 2E ALL VISIBLE ABOVE GROUND FEATURES OF THE EXISTING SEPTIC SYSTEM WERE LOCATED AT THE TIME OF SURVEY AND SHOWN HERE ON. 0 FOUND REBAR %S) SEPTIC VENT tJ WELL -13 2'f V TEST HOLE LEGEND CABLE PEDESTAL A LE, ELECTRIC PEDESTAL TELEPHONE PEDESTAL 4� OF Al% 1 FIREPLACE AMP, CANTILEVER . G2 ' 48TH • �' �l ..... Dayna M. RomfWt ■ ar No. LS 13322 � }� F�Fo ' VIP ` �� 5�� �tZZZ�� ASBUILT - NO CORNERS SET THIS DATE I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF LOT 2A, BLOCK 1, BIRCHWOOD SOUTH SUBDIVISION, PLAT NO. 83-420, ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE IMPROVEMENTS AS DEPICTED HEREON EXIST AS SHOWN IN RELATION TO THE PROPERTY LINES. EASEMENTS OF RECORD OTHER THAN THOSE SHOWN ON RECORDED PLAT No. 83-420 ARE NOT SHOWN HEREON UNLESS OTHERWISE NOTED. I DATE: 10/11/2020 1 FB: 2020-2 GRID: NW 754 1 DRAWN: DMR SCALE 1# = 50' 1 SCALE: 1" = 50' I FILE: 20-022AB r, S Recording District 301 Anchorage CC K A 11/0612020 12:15 PM Page 1 of 2 MA TA NUSKA ELECTRIC ASSOCIATION, INC. LETTER OF NON -OBJECTION Date: October 14, 2020 Gordon S. Hoyt and Judith C. Hoyt, and Kevin B. Dougherty and Doreen M. Dougherty 18905 Monastery Drive, Eagle River, Alaska 99577 Re: Letter of Non -Objection to Encroachment of septic lines in 15' MEA utility easement, (ROW Easement, Document No. 1988-000582-0) located in Lot ZA, Block 1, Birchwood South Subdivision (Plat 83-420, Anchorage Recording District) as shown in drawing dated September 9, 2020. Condition of agreement: The original septic system for property was installed in 1985, and on August 27, 1987, MEA recorded an Electric Line ROW Easement on August 13, 1987, for electrical service to the residence, and now, MEA has no objection to new septic lines being placed within the 15' easement, provided that new lines are placed a minimum of (5ft) five feet from the existing electrical line; and subject to the following conditions: The improvement will in no way restrict or limit the current or future ability of MEA to fully enjoy the benefits of the easement for any and all utility purposes that it presently enjoys under the easement. 2. MEA will be held harmless by the landowner from liability for any and all damages or injury to any person or property that may result from the existing and future use of the easement by MEA, its contractors, or assigns. 3. MEA will be held harmless by the landowner for any and all liability arising out of or relating to any use of the easement by others under a Letter of Non -Objection. 4. The landowner will be liable for any damages caused to MEA facilities by the improvement in the easement. 5. The landowner will be responsible for any special construction costs incurred by MEA due to the improvement in the easement. 8. The landowner will assure compliance with all applicable safety codes relating to the improvement in the easement and stay. 7. Use of this letter by the landowner, their successors or assigns will constitute acceptance of these conditions. 8. Alteration of these conditions shall invalidate this letter. 9. This letter is not effective unless it is recorded in the Anchorage Recording District before ownership of the referenced property is changed from the above-named landowner. Si M. L� 1I SCOPE DE IMEK UnIQU PARAMETERS 1. REMOVE (2) EMSTING STEEL SEPTIC TANKS, BEDROOM: $ (900 epd) 2. PROVIDE (2) NEW SINGLE COMPARTMENT TANKS. NATIVE SOL PERCOLATION RATE: 10A MPI THE UPSTREAM TANK 15 TO BE PROVIDED H1TH PROPOSED CAT 0 APPLICATION RATE: 3 GPD/SF A MINIMUM 20' 0 MANWAY RISER SERVING TIME AREA REQUIRED: 300 S.F. FIRST COMPARTMENT THE DOWNSTREwa TANK IS SYSTEM TYPE: HIDE TACH TO BE PROVIDED WITH A MINIMUM 20" 0 MSM TO HOUSE THE PUIVPI'40 EQUIPMENT IN THE ...� SECOND COMPARTMENT, Uj 3, REBUILD E)OSTING SEPTIC TRENCH. MAX DEPTH OF EXCAVATION IS 5'. MOA FILTER SAND To BE sn � 100' PROTWvE USED TO BRING BOTMM OF NEW TRENCHES UP {y HELL RADIUSM CORRECT ELEVATION. ti 4. ALL CONSTRUCTION TO BE IN ACCORDANCE H1TH La _ ALL REQUIREMENTS SPECIRED IH ANCHORAGE En TREN04 PAlRAV TERS MUNICIPAL CODE CHAPTERS 15.55 AND 1$,65. cs x 72' MADE x 2' EFFECTIVE DEPTH FACTOR (6' t 2)/(6' + 1 t 2.2) = 0.73 + li ca 150 GPD/BR 4 6 SR — 900 GPD I �44% x � 900 CPD / 3 GPD — 300 SF j` 300 SF / 6' VOIDTH = 50' APPROX TOP Cr 50' 4 0.73 = 36.5 MINIMUM LENGTH SLOPE, EIXV 306' m C4 b pr—� J _ ' NEW 1504 GAL 35 � rc TANK ' ` NEW 1OW GAC. TANK & 8R NEW ATS_g u, =1 HOME AERDCELL POD + RATED FOR 6 0 BEDROOMS (s a RELITE SHED 0g �- -- MIF, _. ._ - __. - - ._ L 1s'LA�>�r- - MT r Y CDGE OF PAVEMENT REBUILD pcIST'ING 72" x 3' EFFECTIVE DCP TH TRENCH. MINIMUM LENGTH TO BE 31' MONASTERY DRIVE LONG. Septic Peirnh Dramngv Prepared tar OF HOYT and DOUGHERTY FAMILIES p"�E 18905 Monastery Rd Eagle River, Alaska 99577 BIRCHWOOD SOUTH BLOCK 1 LOT 2A r 4 OSP20138D K.�L� 49111Ja GATE: 9l14�2020 p rCURTIS TOWNSEND � EKLUTNA ENGINEERING, LLC .,c 19162 MOUNTAIN ROAD DRAWN: CLT No. CE 11904 CHUGIAK, ALASKA 9956 (907) 406-1 058 SCALE: 16=W PID: 051-294.28 SHEET 1 QP 2 L 41Aw STATE OF ALASKA) SS - THIS IS TO CERTIFY that on this �-, da ofWC�10020,before me the undersi ned a � Yundersigned, Notary Public in and for the State of Alaska, duly commissioned and sworn as such, personally appeared Manny Loyez, SR/WA.MEA Land Services Manager Known to me and to me known to be the pdividual(s) named in and who executed the foregoing instrument and acknowledged to me that he/she/thi*ei i"� �Mosealed the same as a voluntary act and deed for the uses and purposes therein mentioned." IN WITNESS WHEREOF, I have reunto set my hand and official seal the day anti + I iT"Wmit JNo a ublic in and of Alaska My commission expires •, �, ...,.,•5,��- Return to: MEA, PO Box 2929, Palmer, AK 99645 IIVVI INIIIII�1919'IIIIIRII'll IIIA Page 2MY 2 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this --Lr Da of Lam{,! of 20 'P -b, by and between herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows-, 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS),. described -as %8903" located at (legal descriptio 2. Maintenance, Repairs ani Alterations. (Owner is required to read, understand and initial each section) ,D049 Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed anis produ%iiig treatCu scptiC effiuciit iii accordance with the equipment's approval for operation in the Municipality. 0,0 Ab It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). vwnF,i driccS uiat Giiiy 7iialiiiciiaiiGc diiu icNdii Nciwiiiici aYyivvcu u'ytiic iviwu%,iyaiicy -or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. LV9Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield _ ac, - (rev. 05/18/2018) Page I of 3 TP 1_.____.1_3___.-i__._..7__ AL. . _ 1_ 1`_'._a________ _4 V D OWiler ackfiowleug'es that t1►e 1V1UMUIPWILy 1IIdy [- gUGSt [CCUCUS U1 Ill-Intenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing, to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. 1� Owner agrees to grant the Municipality reasonable access to test and inspect the A XXTT[TT0 TI__' A �(__._'_'.__I'—____'11 i___�nA 1__..._ A VV VV 1 3. 1 IIe 1V1U11juipway VV111 giVC dL IedNL G'+-IIOUf 11VLIC'e. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. �� ►�� Owner agrees that the AWWTS installation and maintenance requirements as provided` by the AWWTS vendor/installer and.approved by the Municipality are the governing iUelllleJ 1UL 611e GU[ISL[UILIUI1, IIId111Le1IdIIUV dIIU repan U1 UIC %JW1IVI 5 /i VV VV 1 0. guide QQt� Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue W1111C LIIG tl VV VV 1 0 6 01JCI�dL10I1d.1 or until L1L'1C IS LId.fISIGrred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. S. Aiiieiit lila nit. Tins Agrees—lent 6-11dii 0111y iJC U111CHUCU vy aU1,I1011GCU ICp1CSC11LULIVCS UL the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at A11cilUrdgc. I HV 1QVVS Ui LHU 3LULU 01 tilashd Slldli g0VCI`It LIIG IIgIIL$ anti UUllgations 01 LIIe parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. Page Id U► 3 J T ATE 0 F ALASKA THIRD JUDICIAL DISTRICT The forego'i14 instrume t was 20 by Y�� mature) Date Q.,��, i�� C�.G• int name) ) ss. ledged before me this�?5 day of* ,,e t" , TIFFANY GLYNN t'AR PUBLIC FOR ALA '1CA Notary Public My Commission expika res: ` a U) . My commis tion Exte pires Mar Mar zo, zozz MUNICIPALITY: By:('� �G�zz� (signature) Date: 'RAs e 0CR ar 1--v �{ (print name) Title: (rev. UJi 183/ 2-0 i o) rage 3 o13 V IA.TS: T By:(sigiiature) Date ,-�-� Vl � L/�)j%(j� �'�a (print name) v CRT A 'rr' r%Tr A r A Or,' A 1.5 i. f`� i. U uj, THIRD JUDICIAL DISTRICT The foregoing instruent was 20� by s1 ss. ) owledged before me this day of �- `° _ F` ' TIFFANY GLYNN U BAR Y f 'fjBL1 ' l'UR ALAS&A Notary Public y COI111111SSIol1 expires: %) r State of Alaska My Commission Expires Mar 20, 2022 NIUNIC" LITS': ny. ' Zl"/ �atL,tltitiucj �&ecca �ra // (print name) ;Date: i0 ' 7L Title: (rev. VJ/ 1 ol! u l o) Pac,,C 3 0,1 3,  "-~ MUNICIPALITY OF ANCHORAGE i,'/ O.~ ~W.i,,~\\~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION ' 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT 1PHONE MAIL,NG ADDRESS? '~' '~O ~ ]'7 3 ? ~ b LEGAL DESCRIPTION LOCATION J NO. O~BEDROOMS ~,STANCETO: _]we,~o ~¢11 ~A~orptionar~ ~I Dwelling' ~Z Manufacturer A/~O~/~,1< ~' W,iJ ;~ Uateria' ~'F< ei N°' °f c°mpartments Z Liq. capacity in gallons Inside len~h Width Liquid depth I ~ ~ IF HOMEMADE: .. - ~ ~ ~ Manufacturer~~ Material Liquid capacity in gallons ~ Well Foundation Nearest lot line a~ ~,s~,c~o: ~o ~ ~11 ~ ' ~ ~op~ile~ofini~lgrade ~ I~ l/ Material beneath tile -3,~ (I i~ Total effective a~o~.~n~, Length Width Depth PERMIT NO. ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ Well B~ilding foundation Nearest lot line ~ DISTANCE TO: ~ ~c,~..a .~q ~.~t, ~r,,,.. ~,.t.n~.to,ot,,n. ,,,M,~,O. ~ ~ ~CEiJ~ TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER ~') V/~'I APPROVED ~a~, ~ ~ DATE LEGAL 72-013 (Rev. 3/78) DEPARTMENT OF HEALTH AND iENVIRONMENTAL PROTECTI SOILS LOG - PERcoLATION TEST SLOPE 1 3 4 5 6 7 10 11 12 13 14 15 16 17 18- 19- 20- oF' COMMENTS PERFORMED BY: Eg SOILS LOG ON CI PERCOLATION TEST .I PERCOLATION RATE TEST RUN BETWEEN CERTIFIED [] SOILS LOG PERFORMED FOR: LEGAL DESCRIPTION: 1 2 4 5 6 7 10 12 13 14 17 18 2O MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 82B L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST [] PERCOLATION TEST SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? S /LO P E IF YES, AT WHAT DEPTH? ~ / Gross Net Depth to Net Reading Date Time _ ,~j~'~ j~yater Drop ~ No. CE-532~ .' ~ ~ PERCOLATION RATE (minutes/inch) TEST RUN BETWEEN COMMENTS PERFORMED BY: FT AND ~ FT CERTIFIED BY: Z(?. ~T 72-008 (6/79)