Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BIRCHWOOD SOUTH BLK 2 LT 1
MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVlRONMEN'rAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME MAILING ADDRESS LEGAL DESCRIPTION LOCATION P,ONE I .EW .[~.'",~t. ~ 2.Ct',~. [] UPGRADE Well [ AbsorPtion area Dwelling DISTANCE TO: ~.~'-C~ C~ cturer ,~ '~ ~.,~1~.0,.~.~Z~~ Material(~,c~.~.~. iF Ft0MEMADE: W dth 3' DISTANCE TO: Manufacturer Well I nside.~e qgth_ Dwelling Material DISTANCE TO: Well ..~_.~ ~, Neare~_~,~il~e No. of of each line f lines Trench wid)h Top of tile tc finish grade Material bene~ le ~. ~ ' Length Width Depth Type of crib Crib diameter Crib depth Well Building foundation Nearest lot DISTANCE TO: NO. OF BEDROOMS PERMIT NO. No. of compartments foundation Liquid depth DISTANCE TO: Liquid capacity in gallons inches PERMIT NO. Distance b~ Total effective absor area_- to Io, z line PERMIT NO. Sewer line S e p t i,c_~n~.,~_.~ 3tion area(s) OTHER PIPE MATERIALS Pv' : SOIL TEST RATING INSTALLER REMARKS David S. Yanoshek ~ APPROVED DATE 72-013 (Rev. 3~78) (~' ,z: " LEGAL Permit Department 825 HANDWRITTEN PERMIT * * * ~F.4,,m..~9 ON-SITE SEWER PERMIT MUNICIPALITY OF ANCHORAGE ~~-~~ ~ Health and Envircnmenta: 'rotection L Street, Anchorage, AK. 99501 ' · 264-4720 Mailing Address: Applicant: Location: Legal Description: L ~ ~ ~)- Type of Soil Absorption System Is: Trench: Drainfield: Maximum Number of Bedrooms: Phone Number: Lot Size: Seepage Bed: ~Tank: Soil Rating(sq.ft/br) The Required Size of the Soil Absorption System Is: DECTH LENGTH GRAVEL ~oTu '"IDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall Pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = / © O O GALLONs * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31~ 1 9 * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the resid, ence is remodeled to S igne~:~~/ ~~/~ Applic~ include more that 3 bedrooms. ate: /- / - & MUNICIPALITY OF ANCHORAGE Department ~ Health and Environmenta 'rotection 825 ~ Street, Anchorage, AK. 99501 264-4720 * * * HANDWRITTEN PERMIT * * * Permit ~~L~_ ~/OR 0N-SITE SEWER PERMIT Applicant: Location: Mailing Address Phone Number: Legal Description: ~/02- ~ ~C;/.~)~ ~,~ -~,~ Lot Size: Type of Soil Absorption System Is: Trench: Drainfield: ,~_ ._ Seepage Bed: Holding Tank: Maximum Ntumber of Bedrooms: ~ Soil Rating(sq.ft/br) The Required Size of the Soil Absorption System Is: DEPTh ? lENGTH .~-~5 GRAVEL DEPTH 2 WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = //)DO GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this departmen~ will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feel for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 8 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) .I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more that 3 bedrooms. Applicant. ' / SWP/024 (1/81) Date: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street. Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SOILS LOG PERCOLATION TEST LEGAL DESCRIPTION= F' KLUTNA 2 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 '~,l ~.c_~woo~ .~ o Lr'r"H SLOPE DATE PERFORMED: I~ /4/~,- -r'o ~N E.T' WAS GROUND WATER ENCOUNTERED? -- ~"'--""~'IF YES, AT WHAT DEPTH? Reading Data Gross Time PERCOLATION RATE TEST RUN BETWEEN S SITE PLAN Net Time Depth to Water 57.. 5¢. '/s sz Drop {minutes/inch) ~5~'~,~ . FT f./l~.., IO, I~E~'?' PERFORMED BY: CERTIFIED BY: DATE: l 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ~. 0 0 0 0 APPLI( NT FILLS OUT UPPER HAl ONLY Property Owner /~! ,~."'~. L / 2 /~/./-/ //Li' ~ Phone MailingAddress ~:"//~ .,~:"' ,~' _~.:.' / 7'~ ~.~:~ /~lC~// ~J~' ZipCode -p~_?/, / ~' ~:~-"- ~' /~"/ Buyer ~/i~: ~' ~- L'~.~/f~:~ --t' ?~, //t,,..'/~ /:27,:'j .-',*.: //1~ //~' ,"- / -~ 7 ~: ~' Address Zip Code Lending Institution ~.t /d A~' ,~ ~J~.~ /.? 7 Phone Address J2r~ ~ <', ~ /~' - /,~ ~ 0 Zip Code Realty Co. &Agent ~::. ~/'/2~,.,d'/.~ /~?~l~ ~/ .~/? ~' ~{~/ ] ~ ~. ..'/2/]~?~ ~.:~/~1 Phone "~ Zip Code Address .~" ~;'~ d ) / [~ '"> '- Legal Description~ / ~ ~_ ~/X~d ~/ ~_~.~ ~g ~ ~ ~ ~ ~ ~ ~ , Street Locati~ ~., /~) ~ ,~ 7 ~ Z: S ~ Type of Resi~nce .~ Single Faintly ~ Multipl~;Family No. of Bedrooms ~ Individual ATTACH WELL LOG. A wall Icg is required for all wells drilled since June 1975. ~ Communit~y For wells drilled prior to that date, give well depth (attach Icg if available). ~ Public Utility Sewer Disposal ~ Individu. I Ye~ Individual Inslalled: / ~' ~ Public Utility When Connected to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSlNG CAN BE INITIATED. Time Time Time Time~L_/_a Date Date Date Date Inspector Inspector Inspector Inspector Field Notes: (,~) APPROVED BEDROOMS *CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL* Soils Rating Date ~wer Installed Well To Absorption Area Well Log Received Well to Tank Septic T~k Size 72-023 (3182) fi unicipality of Anchorage ANCHORAGE, Al A~:~,KA 99502- (g07) '264-4111 T()¢VY KN()WI ^4A Y( DEPARTMENT elf HEALTH AND ENVIRONMENTAl_ |)ROTEC] ION January 4, 1984 Mr. David Yanoshek, P.E. Arctic Engineers, Inc. 1506 W. 36th Avenue Anchorage, AK 99503 Subject: Septic Systems Inspections, Lots 1-4, Block 2, South Birchwood Subdivision Dear Mr. Yanoshek: I have finished review of the submitted as-builts and additional submitted information and the results are as follows: Lot 1: The concrete septic tank does not meet Uniform Plumbing Code (and this department's) specifications for a septic tank. The first compartment is not large enough and there appears to be problems with the inlet and outlet baffles. The specifications are listed in the appendix of the U.P.O., pages 179 to 181 (a copy is attached). Lot 2: The tank is not approved. A possible solution will be to add an additional 500 gallon (approved type) septic tank after the concrete tank; however, a permit will need to be obtained prior to installing it. ~~ ~o- ~o~ I~ Lot 3: The trench absorption area is adequate for 2 bedrooms. If additional bedrooms are desired then an upgrade will need to be completed and a permit ob]~ained. Lot 4: As-builts are acceptable. Thank you for your assistance and for providing the additional information. Sin~rely, Cory Willis, R.S. Acting Sewer & Water Program Manager CW86/ej/E1 cc: Larry Maulden - 3201 C Street Anchorage, AK 99503 FzNQINE. FIIINQ tNNOVAIION I1' FAH N()HIII ARCTIC ENGINEERS, INC. DEPT. OF li"/,Ll'll A ENVIRONMEN I AL PRO i LCI [ON December 9, 1983 RECEIVE 8 -oz Municipality of Anchorage Dept. of Health & Environmental Protection Pouch 6-650 Anchorage, Alaska 99502 Attn: Cory Willis Re: Septic System Inspections, Lots 1-4, Blk 2, South Birchwood Subdivision Dear Mr. Willis: Please add the following information to the appropriate septic system inspection reports for Lots 1-4, Blk 2, South Birchwood Subdivision. Lot 1 ' Enclosed is a blueline of the septic tank installed on this lot and lot 2. One foot (1') of sewer rock was drain tile. installed below the The leach bed was installed at 9' rather than 7' since a basement was installed. The soil is basically the same below 8' as it is from 5' to 8' except that the soil at 8' is called moist to wet rather than "wet" as described for the 5' to 8' layer. Visual observation affirmed that there was little difference between the soils and therefore a 155 soil rating is appropriate. The total bed is approzimately 20.5' x 29' for a total area of 594.5 square feet which is a conservative design. Area required is 465 square feet. ARCT"C ENGINEERS, iNC. RECEIVED AUG. ;31983CONSTRUCTION AND OPERATION CERTIFI.CATE EKLUTNA, ii :.,~?A?"ASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION ANCHORAGE, AL;' PUBLIC WATER SYSTEM- APPROVAL TO CONSTRUCT Plans for the construction of public water system located , Alaska, submitted in. accordance with 18 AAC 80.100 [] conditio Ily approved (see attached conditions). If construction has not started within two years of the approval date, this certificate is void and-new plans and specifications must be submitted for review and approval before construction. . have been reviewed .and are APPROVED CHANGE ORDERS c. nange (contract order no. or descriptive reference) ,~pproved by Date The "APPROVAL TO OPERATE" section must be comp!eted before any water is made available to the public. APPROVAL TO OPERATE The construction of the /..o ]-~ I.~_..~/.~ ]~:'iOC,...~-~Z 5 ~'t~'~c~''epOdc'( Coo.? pUblic water system Was comPleted on '~ "" ~' z/" ""~-~ (date). The system is hereby granted interim approval to operate for 90 days following the completion date. BY TITLE DATE As-built plans submitted during the interim approval period, or an inspection by the Department has confirmed the system was constructed according to the approved plans. The system is hereby granted final~pproval to operate. _ ,~ ARCTIC ENGINEERS, INC. February 14, 1984 AEI# 83-014 MUNICIPALITY OF I'NCHOp.'a,GE Municipality of Anchorage Dept. of Health & Environmental Protection Pouch 6-650 Anchorage, Alaska 99502 RECEIVED Attn: Cory Willis R.S. Re: Lots 1, 2, and 3,~South~'~Birchwood Subdivision Dear Mr. Willis: Reference is made to your letter of January 4, 1984. The concrete septic tanks at lots i and 2 have been replaced with standard steel 2 cell tanks manufactured by Greer Tank (1250 gal., lot 1, and 1000 gal. lot 2). It is my understanding that your department would only give conditional approval to the concrete tanks which would require yearly pumping. We realize ,that the tanks were not constructed meeting "The letter of the .law" but the tanks were oversized and the first cell of each had a usable volume of approximately 700 gallons, which exceeds the required volume. The second cell of each was also 700 gallons which allows additional settlement volume. The "Manual of Septic-Tank Practice" states that a single compartment tank will give acceptable performance and that a 2 compartment tank can have the first cell with a volume of 1/2 to 2/3 of the total volume. The baffle depths were an oversight that should have been caught during construction. They could also have been corrected after installation by simply adding an extra length of pipe on each baffle. We feel that the baffle lengths should have been addressed by D.H.E.P. at the time permits were issued and that a more timely review of the as-builts should have occurred. As-builts were submitted in May 1983 and your request for additional information was not received until December 1983. During this time, our inspector moved to Idaho which made it more difficult to find the required information. After talking to all parties involved with the inspection and installation of the leach fields, I was informed that a very good gravel strata was encountered at the drain tile location. Sidney Clark, P.E. observed the excavation and verifies that GW (85 S.F. per B.R.) soil was encountered on lot 3 at the drain tile depth. The perc test referenced in my 12/9/83 letter was taken approximately 50' from the drain tile and is apparently not ~'~?~ ~ representative of the subject site. ~,.? ~,. We request that unconditional approval be given to lots 1, 2, and 3 for 3 bedrooms. Lot 4 has already been approved. If you have any questions pertaining to this matter, please do not hesitate to call. Sincerely, ARCTIC ENGINEERS, INC. David Yano~shek, P.E. Project Engineer Municipadty of Anchorage POU,.,H 6-650 ANCHORAGE, ALASKA 99502-0650 (907) 264-4111 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Permit #: Handwritten 9 not assigned January 31, 1985 TO: Permit Applicant SUBJECT: Lot 1 Block 2 South Birchwood(Correct Legal: Birchwood Sout~ A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1984. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. ~f you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on, site sewer system, the original as-built inspection report and the yellow copy must be sent to this office for review and approval, and for documentation. If there are any further questions, please call this office at 264-4720. Sincerely, # Keith E. Bandt, Supervisor Environmental Engineering Program KEB/ljw enc: Copy of Permit SWP/057