HomeMy WebLinkAboutBLUE SKIES ESTATES #1 Plat# 98-137 S-10336 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Date: September 23, 1998 To: Zoning & Platting, CPD From:/,~[,James Cross, P.E.. Program Manager, On-Site/Water Quality Subject:[ C'~Request for Comments on Subdlwslons - September 18, 1998 The Environmental Services DMsion, On-Site Services Program, Has reviewed the following cases and has these comments: S-10332: Wagner Estates Subdivision No objections. S-10336: Blu/e,-g-kies Estates Addn #1 [1..Ail soils logs must bear the original stamp and signature of the ~. en=ineers. A& ) 2.. 1 proposed lots must show suitable soils for on-~.te t¢~ V I' -: / wastewater disposal systems per Ax'viC Title I5. S,ztion ~ 1~] } "'-~' % 3 Water availability must be documented. t ~' [ * t / 4 wast exvater disposal reserve areas must be shown }nd must / / meet ali requirements of Chapter 15, including sloce and slope  setback requirements. S-10337: ~urnagain (Plat Note Modification) "No objections. S-10338: Grace Addn #1 Information to satisfy the requirements specified by AMC 21.15 and AMC 15.65 must be submitted for each lot of this proposed subdivision. This information must include, but may not necessarily be limited to: 1. Soils testing, percolation testing and ground water monitoring to confirm the suitability for development using on-site wastewater disposal system. Ground water monitoring must be conducted during high water season in either the fail (October) or spring (April - May). S-I0339: S-10340: S-10341: 2. Areas designated for the original and replacement wastexvater disposal system sites must be identified and must meet all criteria specified in ALMC 15.65 including slope and slope setback requirements. 3. Topographical information must be submitted 4. Supporting documentation on water availability must be provided. Safar Subdivision #2 No objections. Scott's Bluff Subdivision No objections. Borough Public Works (Permit Center) No objections. MUNICIPALITY OF ANCHORAGE I OFFICE USE COMMUNITY PLANNING AND DEVELOPMENT P.O. Box 196650 I REC'D BY: Anchorage, Alaeka 99519-6650 PRELIMINARY PLAT APPLICATION A, Please fill in the information requested below, Print one letter or number per block. 1. Vacation Code 2. Tax Identification No, 3, Street Address 4. NEW abbreviated legal description (T12N R2W SEC 2 LOT 45 OR SHORT SUB BLK 3 LOTS 34). 5. EXISTING abbreviated legal description (T12N R2W SEC 2 LOT 45 OR SHORT SUB BLK 3 LOTS 34) full legal on back page. 6. Petitioner's Name (Last - First) 7. Petitioner's Representative Address ~}~'~ ~"~,t~.{ V ~' ~J~'~D .C~_~'E'~. Address ~J 02- ~,~3 '.' 15~ ~ ' ~ 8. Petition Area Acreage I': 1 I '1 I 13. Fees 9, Proposed 10, Existing Number Lots Number Lots 11, Grid Number III 14. Community Council 12. Zone ] - _ I hereby certify that (I am) (I have been authorized to act for) the owner of the property described above and that I desire to subdivide it in conformance with Chapter 21 of the Anchorage Municipal Code of Ordinances, I understand that payment of the basic subdivision fee is nonrefundable and is to cover the costs associated with processing this application, that It does not assure appr°val °f the subdlvisl°n' lalso understand that additional fees may be assessed if the Municipality's costs to process this application exceed the basic fee, I further understand that assigned hearing dates are tentative and may have to be postponed by Planning Staff, Platting Board, Planning Commission, or the Assembly due to administrative reasons, '~' *Agents must provide written proof of authorization, Please check or fill in the following: 1. Comprehensive Plan-- Land Use Classification Residential Commercial Parks/Open Space Transportation Related 2. Comprehensive Plan -- Land Use Intensity Special Study Marginal Land Commercial/Industrial Public Lands/Institutions Dwelling Units per Acre J-.&~ 5' __ Alpine/Slope Affected Alpine/Slope Affected I ndustrlat Special Study Environmental Factors (if any): a. Wetland 1. Developable 2, Conservation 3. Preservation b, Avalanche c. Floodplain d. Seismic Zone (Harding/Lawson) D. Please indicate below if any of these events have occurred in the last five years on the property, Rezoning Subdivision Conditional Use __ Zoning Variance Enforcement Action For Case Number Case Number -~ '- IL'> ~' Z_ ;~. Case Number Case Number Building/Land Use Permit For Army Corp of Engineers Permit E, Legal description for advertising. F. Checklist 40 Copies of Plat (Long Plat) 30 Copies of Plat (Short Plat) Reduced Copy of Plat (8 l/~ x 11) Certificate to Plat Aerial Photo Housing Stock Map Zoning Map Water: Sewer: Private Wells ~ Private Septic FGG Drainage Plan Topo Map 4 Copies Soils Report 4 Copies Pedestrian Walkwaye Landscaping Requirements Community Well Community Sys. Waiver Public Utility Public Utility ....... ~ -,~, -~ Oct. 02 1997 O6:249H P2 FPOH : ALASI(A I,,IATI~R g~ t,IASTI=klATISR PHOI.IE 1.10. : 90. j_O:3~,46 October 2, 1997 JKP Real Estate 115 West Northern Lighls Bird Suite 205 Anchorage, Alaska 99503 Alaska Water & Wastewater "-'--~1 llh'ook*~dge Drive - Anchorage ~ Alaska 99504 Phone (907) 337-6179 ~, Fax (907} 338-3246 Consulting Engifleers '~. Attn: Klm Paisley Subject: Soils Evaluation for rra~t A, Oonzales S/D. Dear Klm: Per your request, we performed soils tests on the subject tract and evaluated the suitability of the area within the viciulty of the test holes to support an onsite septic system. As we discussed, si,ce we had no surveyed control points, we ate uncel~ain where the test holes ate on thc tract. Three test boles were excavated, but suitable soils were only found in two of tile holes. The holes were excavated to depths of 9-10 feet. Weathered bedrock was encountered at 8.0 to 8.5 feet. No groundwater was encountered. Percolatio, tests were performed, and tire perk rates were less than, or equal to, 1 minute per inch. In short, the soil has excellent absorption characteristics. There were no surface waters within 100 Feet of the test holes, and the topography was witlfin the allowable ranges for installing an onsite septic system. Based upon the information we have available at this time, the subject area will support, au onsite septic system. If you have any questions, please con,ct me at Sincerely, ~~ 337-6177, or 244-9612. Pnnc~pa~ Municipality o! Anchorl~l~e DEPARTMENT OF HEAl. TH & HUMAN ~EHVICES 825 "L" Street. A,chorage. Alagka $19502-0650 gOIL$ LOG ~ PERCOLATION TEST ~ownShilo, Range, Section: ~1~ PLAN WAg GROUNO WAT~rl ~0 I;N~Ot)NTER~D? IF YES, AT WHAT D~PTH? Der)th to Water Drop Nat Pt IDI I1~ I10, : 90733832,16 Oct,. 0.2_ 1997 8B:2GFI.I PC, "'~ ,~' I ~,..':~-:'"' '" "'"' '~ Township. Range, Section: 8LO~ SIT~ PLAN Municipality of Ancl~oltKJe OEPARTMENI' OF HEALTH & HUMAN SERVICES 825 "L" ~3treet, Anchorage, Alaske 9950~-0650 BOIL~, LOG -- PERCOLATION TEST t F'3AL DI~gRIPTION'_ ...... {~T ~ J~ ....~"~-- ~" ~ -~~ _ '.~_~ . - ~,, - _~ .....~ ["~ ~ ', ~ ; ~ ~ . !.~ ....... -- 1 :~t ~ __b'.'. ..... - I" 2~ Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCR,PT,ON: ! / 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O Township, Range, Section: SLOPE WAS GROUND WATER ENCOUNTERED? s L IF YES, AT WHAT ~ O DEPTH? p SITE PLAN E Monlloring? J)/&Y Dale: Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE ~ . ~ (minutes/inch) PERC HOLE DIAMETER {~ ¢'' TEST,U..ETWEEN FTAN F, COMMENTS ...s,,.,...,.,. PERFORMED BY: i i034 F. agie ~,iwr L~p ~,~a~ No, 2i~ - CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WlTl-~lcJJ. ssl~j~li~l]llfJ~l~e~'J~ GUIDELINES IN EFFECT ON THIS DATE. DATE: ~ //~ /el ~' 72-008 (Rev. 4/85) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST Township, Range, Section: SLOPE WAS GROUND WATER ~ O ENCOUNTERED? S L IF YES, AT WHAT ~ O DEPTH? p E Depth Io Water After Monitoring? L~P.. ¥ Date: SITE PLAN Reading Date Gross Net Depth to Net Time Time Water Drop l o - c ,, _ ~ ~ ~ '1 '7 ~/v" ~ ~Iv " PERCOLATION RATE TEST RUN BETWEEN . (minutes/inch) PERC HOLE DIAMETER _ FT AND ~ FT COMMENTS .,,.s...,...,.,. PERFORMED BY:1~,O~.~ "'---k ,-, , ....... I CERTIFY THAT THIS TEST WAS PERFORMED IN ~au ......... j,, .... ,.v..v~ -' / /~(~ ACCORDANCE ~ I~O~J~-~PAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ' (~J /'O 72-008 (Rev. 4/85) PERFORMED FOR: LEGAL DESCRIPTION: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 1 2 3 4 5 6 7 8 9- 10- 11 12 13 14 15 16 17 18 19 2O COMMENTS WAS GROUND WATER ENCOUNTERED? y K~ S IFYES, ATWHAT /0 '/~, ' (~ DEPTH? p E £ Deplh to Water Aller I0 Monitoring? Dale: SLOPE SITE PLAN Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE __ TEST RUN BETWEEN 4~ ~ [minutes/inch) PERC HOLE DIAMETER __ ~ '/~"- FT AND I0 'l..~ FT PERFORMED BY: l_?tt~4 K=~nlA ~v~v L~A~ ~n=~ ~_ ~ . _ · . CERTIFY THAT THIS TEST WAS PERFORMED IN 72-008 (Rev. 4/85) PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMENTS Municipality ol Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST ....... 77'..: ~,~..'t.. ROBERT C. COW~N t,~, DATE PERFORMED: Township, Range, Section: SLOPE WASGROUND WATER JO ENCOUNTERED? . 60# S L IF YES, AT WHAT '~ O DEPTH? p E Oeplh lo Waler After Monitoring? SITE PLAN Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE__~ (minutes/inch) PERC HOLE DIAMETER (~ "' TEST RUN BETWEEN '~ F TAND ¢ F T /~ /r %{ NOT' /~,/C N t~' L' '~ ~'1'(/~ A' Y r~ . S & S ENGINEERING · --*_-;- ..-~- . PERFORMED BY: ]~.~ ~.atlje =,. ~ ~- o~.A lu~ or,.,~ I CERTIFY THAT TH,PS TEST WAS PERFORMED IN · /// ACCORDANCE WIB~IJI~YIJ~fL~J~I~I~J~r~AL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) PERFORMED FOR: LEGAL DESCRIPTION: j~"l" DEPTH (FEET) 3 .)0 .'" 11 13 15 16 17 18 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST / SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? $ L -- O P SITE PLAN E Oeplhto Water After ~,,4.,~/ ~//0/~/ ¢ Monitoring? Date: Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE __ (minutes/inch) PERC HOLE DIAMETER __ TESTRUNSETWEEN ETAND ? FT S & S ENGINEERING ,~1 ...... CERTIFY THAT THIS TEST WAS PERFORMED IN BY: i,;034 Eagle River Loop Road No. 204 PERF ORMED ACCORDANCE WITHJ~m~;iI~I~[~I~S~'OUIDELINES IN EFFECT ON THIS DATE. DATE: ' 72-008 (Rev, 4/85) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20- WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT ~ O DEPTH? p E Monitoring? . Dote: Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE ~ ~ (minules/inch) PERO HOLE DIAMETER TEST RUN BETWEEN ~ ~/2.~ FT AND [/ '/z.. FT COMMENTS .~1 £q~ j3f~l,~l, yji.f f,.t~. ~ _~° ~ J~ ~.4 /~ ~ ~'~ ' C PER~ S & S ENGINEERING ~///~. OfiMED BY: , I ~1 ~ '~ ~"~ CEfiTtFY THAT T~8 TEST WAS PEfiFOfiMED IN 17034 Eagm River L~p Road No. 234 ' - ' ' ACCORDANCE WIT~~~ GUIDELINES IN EFFECT ON THIS DATE, DATE: 72-008 (Rev. 4/85) PERFORMED FOR: LECAL DESOR,PT,ON: 4'r A.dS r Tow.sh*, "..ge. Sec.o : t SLOPE SITE PLAN NEW ADD1TES,~ BOX 4-12'24 ANCHORAGE, ALASKA 99509 M-W DRILLING, Inc. P. O. Box 4-1728 · 2811 Dawson A C 907-27g-]741 ANCHORAGE, ALASKA 99509 MUNICIPALITY OF ANCHOI~.Q~ DEPT. OF HEALTH IENVIRONMENTAL PROTECTIOI~ SEP 1 1 t990 Well Owner John Gonzales DRILLING LOG RECEIVED Use of Well Dom Location (address of: Township, Range, Section, if known; or distance main road hl, Sec ~O, TlgN, R2W, S.M. Upper Huffman Size of easing 6 Static water level Screen ( Describe screen or perforation Well pumping test at 5-5 gallons per of drawdown from static level. Date of completion 15 June 75 Depth of Hole 125 feet Cased to 26 feet ,50 ft. _~a~o~Y~) (below) land surface. Finish of well (check one) open end ); Perforated ( ). None (minute) for 1 hours with 100% x ft. WELL LOG ~Depth in feet from ground surface 0 TO 2 Give details of formations penetrated, size of material, color end hardness Surface Organics 2 TO 25 re. Small Gravel: silty/sandy, few boulders Bedrock: brownt siltstone, small water seaps in fractures .TO TO __.TO TO_. TO.., TO, TO TO_. TO. .TO. TO.. throughout. 1 GPM by 50'.dspth 2 GPM " 1OO' depth Wayne E. hcstber~/ TO_ I -- CUSTOIVLER HUman ~L C~HECKLIgT "' · ~ Other bec'retie ~ ,,;~,~, ,,, DING TANK DATA .Collected by: l ENt~IN~RINO ~ / .Date completed ~.~//'/, r"/'~/ " · g height · ,, ~,. ~'"-----'--~~----W]rea Property prot rte, of le~t ~,ier~,VeI. _~---./_c__~.___ _ /~.__. .v-..~,~_~ ~, .d'_/~ .--'--'~--T~, _ ~.. "· ' , · ,,,,~p enho~e/cleanout...___ /OD ~,- ..... . B, or O, affaeh ADEC letter. ADEC water ayatem number J 1