Loading...
HomeMy WebLinkAboutBRIARWOOD LT 4  MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME IPHONE C/O I E]NEW Pyramid Excavating I 344-8042J ~/JPGRADE MAILING ADDRESS c/o GV.'<,LAB 1131 E. 76thAve. ~101 Anchorage, Alaska 99502 LEGAL DESCRIPTION 24 15 T12N R3W Middle 1/2 of Lot Sec LLz~/L[ LOCATION NO. OF BEDROOMS Our Road off O'Malley I Well I AbsorPtion area Dwelling PERMIT NO. DISTANCE TO:~ ~5'I 9~ ' 48' 85O24O  Manufacturer Material S~ee ~ No. of compartments ~ Greer 2 Liq. capacity in gallons Inside length Width Liquid depth ~ 250 IF HOMEMADE: NA ~ ~ ~ DISTANCE TO: Well ~ Dwelling PERMIT NO, ~ - ~ Manufacturer Material Liquid capacity in gallons  Well Foundation Nearest lot line PERMIT NO. = DISTANCE TO: ~ 6A ' 152' 35' 850240 ' Distance between lines ~ ~ ~ No. of lines Length of each line Total length of lines 49' Trench w~d~6,, inches ~ ~ Top of tileto finish grade~ 49 M~e~i~¢ beneath til~ To¢ctiveabsorptioEarea_ 4' dra~n rock Lq}. ~ inches Length Width Depth PERMIT NO. ~ NA ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Indiv. Depth Driller Distance to lot line PERMIT NO. ~ DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS ~r~i~ field ASTMD2729 See below for other pipe ~~ SOl L TEST RATING ~ ~~ 125 sqft/BR I "[" ~: ,, ~ ~, ~-' Pyramid Excavatin¢4 REMARKS DOW HI 2,, Insulation over septic tank. Building Paper used for silt barrier in drainfield. ~u~~ '~ First 20' of pipe from house to tan~ ff,~t~,L~ Carlon Z-46 ASTM Fl09. This pipe al~.c used for standpipes. {Remainder of ~d f/~ ~ ~ ~ pipe from house to ta~k and tank to drainfield AST~~_~ , APPROVED ~ e-e ..... ~-' ~ ~ DAT~ LEGAL 72-013 (Rev. 3/78) GEOLAB 1131 EAST 76TH AVE, SUITE 101 ANCHORAGE, AK 99502 (907) 344-8042 SOIL LOG _' SOIL LOG PERCOLATION TEST PERCOLATION TEST BEDROOMS JOB NUMBER: PERFORMED .... : .....L ~'~ [4 -- ~ ' ~ ' DATE PERFORMED: 1 2 3 5 7 $ 10 12 13- 15- 17~ 19~ 20- SLOPE SITE PLAN DEPTH (FEET) WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? W E Reading Date Gross Net Depth Io Net Time Time Waler Drop PERCOLATION RATE____~ !_.~!_6'~-__tL~'_~e~. ............... (minutes/inch) TEST RUN BETWEEN __.~.~ .......... FT AND .... ~..~_ .... FT 72 008 25701 Science Park Drive Cleveland, Ohio 44122 216/831-4000 April 17, 1985 Mr. Mike Lewis Anchorage District Office Department of Environmental Control 437 E Street, Suite 303 Anchorage, Alaska 99501 Dear Mr. Lewis, This is to certify that pipe and fittings manufactured or supplied by Carlon Electrical Sciences, Inc., meet the requirements of ASTM F-789-82. In addition, Carlon Z46 PRIME sewer main conforming to ASTM F-789-82 will meet or exceed~ance requirements of ASTM D3034-81 (SDR 35). Sincerely, Ronald R. Bishop, Manager Fluid Systems Engineering lb cc: Mr. Gino Newton Alaskan Pipe-& Supply P. O. Box 3-4088 Anchorage, Alaska 99501 State of Ohio) ) ss: County of Cuyahoga) Sworn to and subscribed before me this/~ day of /¢~__~,~/~. Wanda L. Worthington // My commission expires March 12,~1~]86 INTERNATIONAL ASSOCIATION OF PI.IJMBING OFFICIAI.$ A NOt~PROFITCORPORA'DON RECOMMENDATION OF THE PLUMBING RESEARCH COMMITTEE The product described herein has been reviewed, tested and recommended for acceptance by the Plumbing Research Committee of the International Association of Plumbing and Mechanical Officials as meeting the requirements of the UNIFORM PLUMBING CODE. This recommendation is subject to the conditions set forth in the characteristics below and is not to be construed as assurance or 9uarantee by the Association of product acceptance by Iocal jurisdictions or authorities using the UNIFORM PLUMBING CODE or otherwise affiliated with the Association. Accepted __ ,,Tune 1984 Void after .~ PRODUCT: PV'C Sewer Pipe & Fittings FILE NO. 2420 APPLICANT: Carlon Electrical Sciences, Inc. 25701 Science Park Drive Beachwood, OH 44122 MODEL: Pipe: 4", 6!', 8", 10", 12" & 15" - ASTM F 789 ' - Fittings; 4" & 6" (Solvent Cemented) - ASTM D 2729, D 3033, D 3034 & F 789 (see below) ' 4", 6" & 8" (Elastomeric Gasketed) - ASTM D 3033, D 3034 & F 789 (see be2ow) IDENTIFICATION: Pipe: Manufacturer's name or trademark or trade name · and logo, 'nominal pipe size, the PVC materials minimum cell class~ication, modulus indication, the legend "PS-46 PVC Gravity Sewer Pipe'", ASTM F 789, manufacturer's code (to include day, month, year, shift plant and extruder of manufacturer) and UPC logo. ~;~jrn~O~h~ ~e~r~_raobvOa~ ~, ~ ,h..,e, pe.n.od ,_r~dicated. h_erain a..? is void .a.ffef date, .sh.o~,r~ above. Any ?ange in rna~eda,, marking or design without having firs! d ~.u ~ u, me i-'~umomg. Hesear?n ~ommlnee, .o.r ev~oence ~!~en~ wor, kmansh~p, .or failure lo follow an equitable service policy may be eem? as sufficient cause fo~ ,revocation of thl. s,,recommendation. Reproducaon or or reTerence to this focm fo~ advertising purposes ma be made onl b specific written permission of me Internationa~ Association of Plumbing and Mechar'~:at Offlcals This authorizes lhe u Y Y y covered by this c~rt~cate. · se of the UPC logo on products Any alieratJon of this certificate could be groun(;;tS for revocation of the listing. Sponsors of the Uniform Plumbing Code, Uniform S~r Pool, Spa and Hot Tub Code and Uniform Solar Energy Code. Co-Sponsors of the Uniform Mechanical Code.