ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP211228 PID Number: O 1 � _ H �a - ),D
Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New X Upgrade
Name
David Andersen
ABSORPTION FIELD
❑ Deep Trench ❑■ Wide Trench ❑ Bed ❑ Mound
Site Address
12720 Neher Ridge Drive
❑ Other
Phone
Number of Bedrooms
Soil Rating
depth from original grade
907-250-3741
4
0.6 GPD/SF
JTotal
LEGAL DESCRIPTION
Depth to pipe invert from original Cgrade
Ft.
Gravel depth beneath pipe
2 Ft.
Subdivision Block Lot
Bonnie View 1
Fill added above original grade UN
'•Z &OrP
Gravel length
47 Ft.
Township Range Section-
Gravel width
5 Ft.
Beds: mber of Lines
NA
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
1 000 Ftz
3
10 Ft.
Well
115.0
127.5
NA
NA
NA
TANK ❑■ Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Greer
Capacity
1250 Gal.
Surface Water
NA
NA
NA
NA
Material
Number of compartments
Lot Line
25
11.25
NA
NA
NA
Polyethen
2
Foundation
17.5
33.75
NA
NA
LIFT STATION
Manufacturer
Capacity
Remarks
NA
Gal.
Alarm location
Electrical installed by
Installer
PIPE MATERIAL House to tank 3034 drainfield Tank to
3034
Northern Excavation
Drainfield 3034 CO/MT3034
inspector David Andersen
BENCH MARK (Assumed elevation) 100 ft
Inspection 15` 10-22-21 2nd 10-25-21
Location and description
31d 10-26-21 41h
Top of Septic Tank Lid
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
ol=
Conditional Approval: Date
�. A�s#t!
Q
ow JH*
.., A,
David L. Anderson _ frf
�� '� CE -9350
0�r��F .t 1-23-21..•
Septic System Q�
Approved (l��Zai�' Date 2 3 z 1
Note: this does include
OXI
k%1%,%. ~
approval not well permit requirements.
,RCV UJ/U4/ 10) ,�. -Te s+ ey� 0_, am..n r t lots S uff vz�k `-re^c_V% +o`vJ
Response To MOA Septic and Well Review Comments
November 2, 2021
1. Submitted as -built survey to scale.
2. Submitted record drawing to scale.
3. Inspecting engineer was recorded on the inspection report.
4. The soil design septic rate was 0.6 gal/sf and was recorded.
5. Septic area was added as 100 sf.
6. Tank manufacture was Greer and was recorded.
7. All pipe installed was ASTM D3034
8. There is no available well log. Based on the information give from Denali Drilling the
well is 335' deep. At about 17 feet bed rock was encountered and at about 330' a large
fracture in the bed rock was encountered. Underground water flows through the
opening. The well pump was set at 335'. The ground water head is at about 17 feet.
9. 2 inches of foam insulation board was placed over the tank prior to placing the cover.
10. Swing ties from point B was corrected.
11. The ground point elevations at 14 and 15 were corrected.
12. A table was placed on the record drawing listed the original ground elevations, new
ground elevations, invert elevations, bottom of trench elevations, depth of trench
excavations, cover depth, trench cover, and drain rock depth. Note that trenches 9-19,
10-18, 11-17, and 12-16 have 2 inches of foam insulation board prior to cover.
13. The drain rock in both inactive trenches is 2 feet and is indicated on the record drawing.
14. The ground water monitoring pipes were about 10 feet deep and were observed on 10-
10-1995. There was no water in the monitoring well. This is indicated on the drawing.
15. The depth of trench cover is listed on the record drawing. Foam insulation was placed
over the trenched before soil was placed over the piping except for trench 6-8.
The COSA comments were corrected.
David Andersen, P.E.
11=20'
30'
Swing Ties
A B
1. 12.2' 1. 58.3'
2.21.5' 2.58.1'
3.24.3' 3. 59.0'
4.25.3' 4.59.4-
5. 34.9'
.59.4'5.34.9' 5. 70.4'
6.34.6' 6. 71.7'
7. 75.4' 7. 97.6'
8. 79.4' 8. 99.6'
9. 78.7 9. 81.6'
10. 81.5' 10. 74.9'
11. 91.9' 11. 75.3'
12. 108.0' 12-78.7'
13.98.7' 13. 67.5'
14. 81.7' 14. 63.0'
15. 90.7' 15. 52.1'
16. 79.5' 16.35.2'
17. 58.4' 17.27.1'
18.46.6' 18. 33.5'
19.38.2' 19.43.9'
10's
BONNIE VIEW SUBDIVISION
SEPTIC SYSTEM LOT 11
ASBUILT 0.561 ACRES
10' Setback
7 W
1 8
- Active Septic Trench 6
•--------------------------
Trench Length = 47' •
I 5
Distribution Box 4^ ? IA
N I 1 B 1250 Gal
M I TH-1(BOH Elev. = 94.8) Poly. Tank
I Note below
Risers
209.11'
N 89055'20"E 209.E
Note: 2 inches of insulation board was placed over the
septic tank prior to cover.
L0
12' N
b 13.7'
X12.3'
A
Li
y M
W
0
0
W M 00,
U SOA
O,Q
oy
60.
32.0'
d EXISTING BUILDING
ground water was
m 10 monitoring well
6.0'
13.0' 100, W
CONC.
34.5'
MW-21(no ound water was a
observed in 10 monitoring well
10-10-1095
Relative Ground Elevations N 89-55'20"E,209.78'(REC)
IA 100 09.11'(MEAS)
113.
w
o
v
1 9 Trench Length 40'
1.
Oy
01
------------------
Relative Ground
Elevations
Inactive Septic Trenches
19
19. 98.69
Original
Septic Trenches
I
Invert Relative
3
3
10 at rest.
Elevations
roi
I -------------
Elevations
4.
100.21
__
I Trench Length 40'
ot18
- - - -
0
0
O
O
_
100.21
Z
Z
" rl l SEPTIC SYSTEM
100.21
Trench 6-8 - (6)
, 14
96.23
7.
------------
-
96.56
Q9 -21S 96.21
Trench Length =
-------
47' 17
99.21
Trench 11-17 -(11)
I 0
99.67
92.25
90.25
TH-2(BOH Elev. = 89.5
MW -1(n
(17)
N
o observed'
10.
1
10-10-10
91.58
92.21
112 1'
16
11.
95.25
I----------------- -15----------
Active Septic Trench
90.13
Trench Length = 47'
I
12.
Risers
209.11'
N 89055'20"E 209.E
Note: 2 inches of insulation board was placed over the
septic tank prior to cover.
L0
12' N
b 13.7'
X12.3'
A
Li
y M
W
0
0
W M 00,
U SOA
O,Q
oy
60.
32.0'
d EXISTING BUILDING
ground water was
m 10 monitoring well
6.0'
13.0' 100, W
CONC.
34.5'
MW-21(no ound water was a
observed in 10 monitoring well
10-10-1095
Relative Ground Elevations N 89-55'20"E,209.78'(REC)
IA 100 09.11'(MEAS)
113.
99.67
1.
100.42
18. 97.48
Relative Ground
Elevations
2.
100.21
19. 98.69
Original
New Ground
Invert Relative
Bottom of Trench
3.
100.21
Elevations
Elevations
Elevations
Elevations
4.
100.21
Tank Inlet 1-
100
100.42
5.
99.96
Tank Outlet 3 -
100
100.21
96.79
6.
100.21
Trench 6-8 - (6)
96.23
7.
99.46
(8)
96.56
Q9 -21S 96.21
94.23
8.
99.21
Trench 11-17 -(11)
93.50
99.67
92.25
90.25
9.
97.67
(17)
92.29
10.
96.67
Trench 12-16 - (12)
91.58
92.21
90.08
88.08
11.
95.25
(17)
90.13
12.
92.21
Inactive Trenches
13.
92.46
10-18 (10)
95.33
96.67
94.37
92.37
14.
95.58
(18)
94.41
15.
93.25
9-19 (9)
95.79
97.67
95.57
93.57
16.
93.21
(19)
95.59
17.
95.25
WELL
RAP DRIVE
56.4'
f
30'
of Trench Trench Total Trench Drain Roel
ava Cover Depth De y,�q,�,�_,
AW Ayr -
2.33'
2.33' 2.98' 4.98' 2' i * 49
3.15' 3.0'+ 2" Foam 5.0' 2' 00... _ ..
00 �00
3.5' 2.13'+ 2" Foam 4.13 2' Oavid l Andersen W .'ri
%G� CE -9350 g''ww
2.96" 2.30'+2" Foam 4.3' 2' `t't�;p ' .,11, 21-21.
low
2.22' 2.10' + 2" Foam 4.1' 2' i I III,I I Y1i�kb'
W
0
R'
W
W
Z
30'
1 "=20'
PLAT NO. P-655
BONNIE VIEW SUBDIVISION
LOT 11
0.561 ACRES
,>nci 11,(MEAS)
S -BU I LT
GASTALDI LAND
SURVEYING, LLC
JEFF A. GASTALDI, R.L.S.
12000 E. DOWL ING RD., SUITE E
ANCHORAGE, ALASKA 99507
PHONE 248-5454
I
GRIDSW2840 I D1 /2/2021 I
F.B.
2021-02
JOB NO.
BVSLOT1 I
1 HEREBY CERTIFY THAT I HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO
ENCROACHMENTS EXIST EXCEPT AS INDICATED.
IT IS THE RESPONSIBILITY OF THE OWNER TO
DETERMINE THE EXISTENCE OF ANY EASEMENTS
COVENANTS OR RESTRICTIONS WHICH DO NOT
APPEAR ON THE RECORDED SUBDIVISION PLAT.
UNDER NO CIRCUMSTANCES SHOULD ANY DATA
HEREON BE USED FOR CONSTRUCTION OR FOR
ESTABLISHING BOUNDARY OR FENCE LINES.
ANCHORAGE RECORDING DISTRICT, ALASKA
NOTE: NO CORNERS SET THIS DATE.
�'6*1.%0a
OF 1�
•A�, .sem
100
Jeffery A. Gasialdi : c
. •. LS-6091AIF. �'N •.
11/2/2021 ,: `P•
�••,Pap ••......•• � a5°��
r0fessionol
1 salk
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP211228
Work Type: SepticMM Upgrade
Tax Code Number: 01742220000
Site Legal Address: BONNIE VIEW LT 11 G:2840
Site Mailing Address: 12720 NEHER RIDGE DR, Anchorage
Owner: ANDERSEN DAVID & ANGELA
Design Engineer: ANDERSEN DAVID
This permit is for the construction of:
Effective Date
Expiration Date
Lot Size in Sq Ft
Total Bedrooms:
,iz'ent
t
Department
6/29/2021
6/29/2022
24150
Cf Disposal Field CEJ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
4
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
i;
Special Provisions: The inspection report & record drawings to close out this permit shall include information to
close out the 1995 permit.
--- t USO ciR + f er w -.L4 . — 12M C '27
/I I ZO2 l
Received By: Q Date:
Issued By: �� ,� a v'yc � S( Date: a oI, t
M r7
Development Service,..
�s Department �
p `�� � Phone 907-343-7904
On-Site Water & Wastewater Section Fax. 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 01742220
Property owner(s) David and Angela Andersen
Mailing address PO Box 111745 Anchorage Alaska, 99511
Site address 12720 Neher Ridge Drive
Day phone 907-250-3741
Legal description (Sub'd., Block & Lot) Bonnie View Subdivision, Lot 11
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(M all that apply)
Absorption Field
❑X
Initial 0
Single Family (SF) 0
AD U)
Septic Tank
©
Upgrade 1-1(w/wo
(D) El
Holding Tank
❑
RenewalDuplex
❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 9 J + 9 310 Waiver Fees: _
Date of Payment: 9 8/2.0,2 @ '7/1311 1 Date of Payment:
Receipt Number: 9, 1 Q .26612q Receipt Number:
Permit No. 0 S 10 ), I 1 q a1�
Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
August 9, 2021
Revised Septic Tank Replacement and Septic Field Modifications
Property Location: 12720 Neher Ridge Drive, Anchorage, Alaska 99516
Bonnie View Subdivision, Lot 11
The scope of this project is as follows:
1. Replace a leaky metal 1200 gallon septic tank that is 26 year old with a Greer HDPE septic tank
with a 4 foot riser, and
2. Install a Plylok RHINO Baffled Distribution Box with 10 Holes.
3. Install a new 5' wide by 47' long trench in the reserve area.
4. Extend two existing septic trenches by 7 feet in the southern most area of the septic trenches.
5. Route new piping to the distribution box.
6. Plug septic piping to the existing northern trenches and put at rest.
The existing condition of the septic system was evaluated, and the upper two northern trenches are
currently full but not leaking effluent on the ground surface. The effluent was stopped for 2 days and
the water level in the trenches dropped 8 inches.
The bottom southern trench has no effluent flowing into it. A water test was conducted on the trench
and 400 gallons of water was metered into the trench. No water was measurable after 24 hours. The
second southern trench has effluent and is operating normally. No effluent was measurable after 30
hours.
The septic upgrade and modifications as shown on the site plan will not impact any adjacent lots.
David Andersen, P.E.
907-250-3741.
b 1' 5 15 aO 30 q 115 U
Existing septic trenches placed
a rest. Plug flow lines at
distribution box for each
trenches as shown in clouded
area.
111=20'
30'
IExisting Monitoring
Tubes (Typ)
L40
'3U
8% Slope (Slope
increase at property
line.
Septic System Up -grade Design
12720 Neher Ridge Drive
Bonnie View Subdivision Lot 11
N 89°55'20"E
9nd i, -(MEAS)
20978'(REC)
209:11 (MEAS)
OF AS'rr�►
� ti
CO
49 TH -
... ..? L �
David L. Andersen a;r
/f N CE•9350 .' 2���
r
��( � C�� 7
♦t' ! i WOFE5SIVAot �
l\\1
D* t
w
AT INVERT OF DRAIN PIPE
1'
- • - • - • - • - - 1 • v • • ; i •. - -
♦ • • • • • la•� • • :%•%••X.
• • • i • • • �•• L,•.
• • • f • 1� • a •ol .
5'
SEQTM
135 AIAJI C' VICE-) 3 C4 $ D/V1310k) J� 1 I
CA ,1
Andersen Resident
Existing
Property
Comer
Septic System As -Built
12720 Neher Ridge Drive
Bonnie View Subdivision Lot 11
LOT 12
209.
10' Setback
1250 GAL
RESERVE AREA
CLEAN OUT (TrP
13.5'
TH-1
Q TH-f
AC77VE��ARI.
e - - 7
' 61
I e I 27 35 I
i 5 10 15 20 3U yu _ 5v W 70 S'U 4o 100 1,10 12a 130
N89 55'20'*E
°" _ _ _ - - _ / Power Pole
Lot 11 Buried Power Line _ _ - - - _ - -
Buried Drive Way Grass
Well Power. Island
° Line
,q,', Well
Buried Water--_
•1 0 \.\��\\ Line
31' —
Q
m_
J
vu
9
x 37'�
Flow Splitter
Zable Z-200
(Typ)
209.78' s89 393
QMW-2 100'
ZLBuried Dry Sump
24" diam culvert
4' long. Approx.
3' deep.
I 4 TE PL JA'NLOT 10
�r,nr�►� Uld� sU$D�t,'/Sro. AEU uN -E �, i vLffi 14DbNiov AAP FLOW SP/ftM
SCALE 1"=30° NOTE_- MW -1 IS AN E YJS77NG MONITORING WELL AT A DEPIN OF 100
MW -2 IS AN EXIS77NG MONITORING WEILL AT A DAP77-I OF 9'
1
Er
Pr
C(
FIELD
LU
V
W
W
z
7RENGH GROSS SEGr10N (Typ)
733AIAlIG Ver,) 3U6DN13GJ 4,11 -It
OF A4.1
�.' 01
-* 49T" * 00
/..... I/
,!
David L. Andersen a
A1� CE -9350
•-.6-18-21 d
�QpROFESSIW"'
4�A1'�s4q��
EMM
T
BONNIE VIEW O
LOT 11
0.561 ACRES
209.1 VNEAS)
VA
GASTALDI LAND
SURVEYING, LLC
JEFF A. GASTALDI, R.L.S.
1000 E. DOWLING RD., SUITE 8
ANCHORAGE, ALASKA 99507
PHONE 248-5454
I
GRIDSW2840 I 6/5/2021 I
F.B.
2021-02
JOB NO.
BVSLOTII
N 8955'20"E 209.78'(REC)
209.11'(MEAS)
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO
ENCROACHMENTS EXIST EXCEPT AS INDICATED.
IT IS THE RESPONSIBILITY OF THE OWNER TO
DETERMINE THE EXISTENCE OF ANY EASEMENTS
COVENANTS OR RESTRICTIONS WHICH DO NOT
APPEAR ON THE RECORDED SUBDIVISION PLAT.
UNDER NO CIRCUMSTANCES SHOULD ANY DATA
HEREON BE USED FOR CONSTRUCTION OR FOR
ESTABLISHING BOUNDARY OR FENCE LINES.
ANCHORAGE RECORDING DISTRICT, ALASKA
NOTE: NO CORNERS SET THIS DATE.
OF A4 A
�� °e.ee..oy• 9.n
9
49TH
........................
... .................
m Jeffery A. Gastaldi : o
'p• LS -6091 :AV
s�P °.• 8/5/2021 ; �J
ArofessionaI L�
Rick Mystrom,
Mayor
Mtmicipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
October 23, 1996
David & Angela Andersen
8210 Barnett Drive
Anchorage, Alaska 99518 2465
Subject: Lot 11 Bonnie View Subdivision
Permit #SW950354, PID #017-422-20
The subject permit, issued October 23, 1995 by this office for a
single family well and/or on-site wastewater system, has
expired as of October 23, 1996.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. Ail inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
/
Sincerely, ~
Prdgram Manager
On-site Services
enc: Copy of Permit
MTJNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HLTMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
PAGE ~ OF
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW950354
DESIGN ENGINEER:
OWNER NAME:DAVID L. ANDERSEN
OWNER ADDRESS:8210 BARNETT
ANCHORAGE, AK. 99517
PARCEL ID:01742220
LEGAL DESCRIPTION:
BONNIE VIEW LT 11
LOT SIZE: 24150 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT:
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
DATE ISSUED:10/23/95
EXPIRATION DATE:10/23/96
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) .
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
A DHHS REPRESENTATIVE MUST INSPECT EACH OF
THE PROPOSED TRENCHES PRIOR TO THE PLACEMENT
OF SEWER ROCK. THE INSPECTION MUST TAKE PLACE
BETWEEN THE HOURS OF 9: 00AM AND 4: 0OPM MONDAY
THROUGH FRIDAY. INSPECTIONS REQUIRE A 24 HOUR NOTICE.
DATE-
DATE:
Zabel Z200F10w Divider' Zabel Z200 D F10w Director
BRAND NEW FOR 94- The Zabe[ Flow Divider replaces old fashioned distribution boxes and pipe manifolds
and The Zabel Flow Director replaces expensive, old fashioned Y-valves. They are also more effective and easier
to install. Ail Zabel products are manufactured ~om high quality injection molded PVC and carry Zabel's
Lifetime Warranty if parts fail due to manufacturer s defect in material or workmanship. The warranty does not
include replacement parts not sold by Zabel and does not include labor for removal or reinstallation.
1. The Flow Divide distributes effluent leaving the 1.
septic tank by means of a patented central weir
design that insures the flow is evenly divided even
if the Flow Divider is not perfectly level.
,...' The inlet pipe of the Flow Divider is constructed
so that effluent will flow from it and down into the
effluent into two equal portions.
Distributes flow better than D-boxes and mani-
folds that are subject to frost heave or ground
settling.
Testing shows that even with a level discrepancy
of 1/8" or more between the right and [eft port, the
division of the flow was almost 50/50. A standard
D-box or manifold distorts the flow under these
same conditions.
o
The Flow Director is a Flow Divider with a pat-
ented sleeve valve installed to distribute the efflu-
ent flow to a primary field of your choice and
allows the secondary field to rest until needed.
The Flow Divider automatically back flows from
the primary to the secondary field and does not
depend on the homeowner to change the sleeve
valve in the Flow Director. A standard Y-vaNe is
dependent on the homeowner to change the flow
direction at the proper time. Unfortunately, this
usually does not happen and a problem develops
such as an effluent break out resulting in ground
water contamination.
At the time the septic tank is normally serviced,
the septic tank service company can redirect the
flow allowing the primary field the opportunity to
rest.
· Manufactured from injection molded PVC.
· Always insures an even flow.
· Doesn't create solids build up.
· Will not clog.
· Lifetime Warranty.
Laboratory Test Results using
1000 ml samples @ 3 gpm
Level
Right Port
Left Port
1/16" Tilt
Right Port
Left Port
1/8" Tilt
Right Port
Left Port
Average
Distribution
50.03%
49.97%
50.2%
49.8%
51.3%.
48.7%
Questions concerning Z200 Flow Divider · Zabet Z2OO-D Flow Director please call
1-800-221-5742 or Fax (502) 267-8801 for further information.
Z200.O I - I 1/94
PA TRICK ROAD
.. 1.16.4.9' NO 13'30"W
116.49' SO 15'$0"E
NEHER RIDGE
0
61.67'
000000000000
00000000000
000000000000
00000 0000
0000 0000
000 ~0000
000 0000
000 00000
000 00000
000 ~00000
000 00000
000 000000
000 0000
000 '0000
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L' Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCRIPTION:
2
3
4
5
7
9
,3
10 ~'"
,O
11
~3
14
16
17
19
2O
DATE PERF¢
Township, Range, Section: ~(:- ~-- T'/Z/~
SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED? .A/O
L
IF YES, AT WHAT ~//~.~ O
DEPTH? /~//'~r P
E
Depth to Water Alter
Monitoring? M,c'~ Date:
Gross Net Depth to Net
Reading Date Time Time Water Drop
'~. ~ o ¢,~ 3,~,,,,~ ',J I ~/>~ " I-'~/'.~
PERCOLATION RATE ~'~*~ (minutes/inch) PERC HOLE DIAMETER
- Z
TEST RUN BETWEEN =-~ FT AND ~'~ Z. ET
COMMENTS
PERFORMED BY: ~)~,-{//t_~../~,~,j'/.')E_~-YZ..~"~-~-'~ I '-~'~FY THAT THIS TEST WAS PERFORMED IN
ACCORDANOE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE'. ( ¢"'~/I(~f'~ ~,~
72-008 (Rev, 4/85)
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
2O
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
"bEPTH:~ O
;,;~ ~ ' P
Depth to Water After__ ./..
Monitoring? ~ ~/~ Date:
I~ % ~ ,: ~'~ .:~
...,..
DATE PERFORME~',.
Township, Range, Section:
SLOPE SITE PLAN
I
Gross Net Depth to Net
Reading Date Time Time Water Drop
lO ~;,v 3 ~1~'
z3, rs',
cOMMENTS
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
72-008 (Rev. 4/85)
(~ o- ~ o ~' tO ~4tro
PERCOLATION RATE~ *~ (minutes/inch) PERC HOLE DIAMETER
THINGS TO DO
TODAY
DATE
15
16
17
18
19
2O
91-009(3/76)
October 5, 1995
Municipality of Anchorage
Department of Health and Human Services.
Anchorage, Alaska 99521
Attention: Jim William
Subject:
Bonnie View Subdivision Lot 11
Dear: Mr. William:
The following list is in response to the comments regarding the septic design for the Bonnie View
Subdivision lot 11.
1. The new site plan shows the correct location of the test pits.
2. The sit plan shows two monitoring wells that were installed prior to this investigation and are
shown on the site plan. The depth of these wells are 9 to 10 feet deep and there is no water in the
wells as of October 1st, 1995.
3. The existing septic field east of lot 11 is 110 feet from the proposed well on lot 11. This is
shown on the site plan.
4. The proposed trenches are shown to be 1.5 feet deep. The logs indicate a SM classification. It is
not an organic material.
5. A percolation test was performed at a depth of 3.5 feet which was in the layer classified as an
ML in test hole 2. The percolation rate is 22.9 min/in. The trenches are placed in the soils yielding
11.7 min/in placed 2 feet above the ML layer, which is the recommended separation above a more
restrictive layer.
6. The filter in the septic tank had been deleted from the plans.
I~vt~ anW~a~t~ns regarding the test methods or the results, please call me.
September 22, 1995
Municipality of Anchorage
Department of Health and Human Services
Subject: On-Site Sewer Permit
Dear Sir:
This package contains the following information for your review and approval of an on
site septic system to be located on lot 11 of Bonnie View Subdivision:
-Septic design and layout, details
-Site plan
-Septic calculations
-Percolation tests and soil logs
The drain field is designed using a 5 foot wide trench. The definition of a trench is 5 feet
wide or less according to the definitions in the regulations. The trench application rate of
0.8 gpdsf was use to design the drain field based on the percolation rate obtained from the
percolation test shown on the soil logs. The drain field is designed with three 50 foot
trenches. The trenches will be placed at 1 1/2 to 2 feet in depth, leaving a two foot
vertical separation from the bottom of the trench to the dense gravely silt as shown on the
soil logs.
The design specifies the use of a flow splitter basin made by Orenco Systems, Inc. which
provides equal distribution to each drainfield trench. Flow to the drainfield is by gravity.
All of the setback requirements are met as specified by the Department of Health.
The site plan depicts adjacent properties within 200 feet of the property being considered.
The septic system and proposed well are placed on the lot to minimize the impact on the
adjacent lots l0 & 12. As seen on the site plan the proposed well does not interfere with
any existing or proposed drainfields within 100 feet. The septic system and well
locations were specifically placed on lot 11 to allow the space needed on lots 10 and 12
for a drainfield and well on each lot. For example, a drain field can be placed on lot 10 in
the Southwest corner of the lot without interfering with the proposed well on lot 11. Th~'
drainfield for lot 12 can be placed on the northwest corner without interference with the
well setback on lot 11. Wells on lots 10 and 12 can be placed on the east side of the lots,
allowing the required 100 foot setback from all proposed and existing septic systems.
There appears to be no sign of surface drainage across lot 11 from any adjacent
properties. There was no ground water or bedrock encountered to a depth of 10 feet.
There is 8 1/2 feet of vertical separation from the bottom of the trench and investigated
depth without the encountering of ground water or bedrock which meets the vertical
separation requirements of the Department of Health.
Insulation will be placed over the trenches and drain pipes to ensure a frost depth
protection during the winter months.
The proposed septic system for lot 11 Bonnie View Subdivision meets all the
requirements of the Department of Health. If you have questions, please feel free to
c ont ac.~l~_ ~\\,
PA TRICK ROAD
116.~19' NO 15'$0'W
116.49' SO 13'$0'E
NEHER RIDGE
CIOWL BNIIINBBRB
ALAB~ TE~TLA~
Project Name
OOMPUTATION~
W.O.#
Client Name
Prepared by:
Date
Sheet
Checked by:
of
Date
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
COMMENTS
Township, Range, Section:
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Deplh to Water
Monitoring? /~ I/,/-(-- Date:
SLOPE SITE PLAN
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERFORMED BY:
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
72-008 (Rev, 4/85)
PERCOLATION RATE 11'7 (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN ~- FT AND ';~ ET
OCT-- 1 6--9~ MON 9 ~- 40 ]3HHS
4
?
~7
~8
2O
Municipality o! Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
835 %" Street, Anchorage, Alaska 9950~.-0650
SOILS LOG -- PERCOLATION TEST
Township, Range, Section;
SLOPE
WAS GROUND WATER
EN¢OUNTERIED?
PLAN
IF YES, AT WHAT
DI"'PTH?
GrcS$ NeT Depth to Not
Roading Dote Time Time Water,,~ Drop
PERCOLATION RA'~E ~ [mmutes/Lnch) PERC HOLE DIAMETER
OOMMENT$
Municipality of Anchorage
Department of Health and Human Services
Subject: On-Site Sewer Permit
Dear Sir:
MUNICIPALITY OF ANCHORAGE:
ENVIRONMENTAL ,SERVICES DIVISION
AUG 1 8 1995
RECEIVED
This package contains the following information for your review and approval of an on site
septic system to be located on lot 11 of Bonnie View Subdivision:
-Septic design and layout, details
-Site plan
-Septic calculations
-Percolation tests and soil logs
The septic system is designed to use two 5 foot trenches at a length of 59 feet. The design of
these trenches meets the criteria as outlined by the Health Department for a reduction of
drainfield size. The reduction factor for this design is 0.78. The trenches will be placed at 1 1/2
to 2 feet in depth, leaving a two foot vertical separation from the bottom of the trench to the
dense gravelly silt as shown on the soil logs.
The design specifies the use of a Zabel Z200 Flow divider which provides equal distribution to
each drainfield trench. Flow to the drainfield is by gravity. All of the setback requirements are
met as specified by the Department of Health.
The site plan depicts adjacent properties within 200 feet of the property being considered. The
septic system and proposed well are placed on the lot to minimize the impact on the adjacent lots
10 & 12. As seen on the site plan the proposed well does not interfere with any existing or
proposed drainfields within 100 feet. The septic system and well locations were specifically
placed on lot 11 to allow the space needed on lots 10 and 12 for a drainfield and well on each lot.
For example, a drain field can be placed on lot 10 in the soutwest corner of the lot without
interfering with the proposed well setback on lot 11. The drainfield for lot 12 can be placed on
the northwest corner without interference with the well setback on lot 11. Wells on lots 10 and
12 can be placed on the east side of the lots, allowing the required 100 foot setback from all
proposed and existing septic systems.
There appears to be no sign of surface drainage across lot 11 from any adjacent properties.
There was no ground water or bedrock encountered to a depth of 10 feet. There is 8 1/2 feet of
vertical separation from the bottom of the trench and investigated depth without the encountering
of ground water or bedrock which meets the vertical separation requirements for both ground
water and bed rock of the Department of Health.
Insulation will be placed over the trenches and drain pipes to ensure a frost depth protection
during the winter months.
If you have questions, please,~e~,~fre0: tp, c~ onfact me.
Sincerely,
William P. Hamm, P.E.
COMPUTATIONS w.o. #
ClOWI. ENI~INEEFIB
AL.ABICA TEBTI.~B
ProJect Name
Client Name
Prepared by:
Date
Checked by:
Sheet
of
Date
PERFORMED FOR:
LEGAL D ESCR I PTION :~,~
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
COMMENTS
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
Township, Range, Section:
SLOPE
WAS GROUND WATER
ENCOUNTERED?
7,,'zk] .F-.,z,v' $ z~
SITE PLAN
S
L
IF YES, AT WHAT O
DEPTH? p
E
Depth to Water
MonitorinD? , _ Date:
Reading Date Gross Net Depth to Net
Time Time Water Drop
~ ~/~¢ ~'~'. ~" ~" ~/~
TEST RUN BETWEEN ~-
PERCOLATION RATE !/, r~ (m,nutes/inch) PERC HOLE DIAMETER
FT AND ~ FT
PERFORMED BY:
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
72-008 (Rev. 4/85)
CERTIFY THAT THIS TEST WAS PERFORMED IN
DATE:
DO,VI. ENI31NEEFIB
Project Name
COMPUTATIONS
Client Name
W.O.# .._.
Sheet __ of __
Date
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
LEGAL ~'
DESCR,PT,ON J
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
COMMENTS
PERFORMED:
Township, Range, Section:
SLOPE SI'I~E PLAN ~"
1
s
L.
IF YES, AT WHAT O
DEPTH? p
E
Depth to Water Alter
Monitoring? Date:
!
Gross Net Depth to Net
Reading Date Time Time Water Drop
?- ~ .- ~ o' /o" &" Z
~ ' tO~
PERCOLATION RATE ;~'7~?--(minutes/,nch)PERC HOLE DIAMETER ~',r,,
TEST RUN BETWEEN I FT AND ~ FT
P~, ~'r ~- ~ ~) TP- ~
PERFORMED BY:
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
72-008 (Rev. 4/85)
CERTIFY THAT THIS TEST WAS PERFORMED IN
DATE: ;
j DOWL. ENI~INEERB
wod..Ael(A 'rEs'ri. AB OOMPUTATIONS
ProJect Nome Clle-t Nome
W.O.#
Sheet of
Date
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: (907)343-7904
On -Site Water & Wastewater Section Fax: (907)343-7997
Certificate of On -Site Systems Approval
OSC251117
Parcel ID 017 -422-20
Legal description BONNIE VIEW LT 11
site address 12720 NEHER RIDGE DR
Expiration Date: 3/3/2026
Current property owner(s) HALL ASHLYN & MATTHEW
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or conditions:
By:
Original Certificate Date:
4/11/2025
Thi�Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
sy9tem(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage,
Development Service Department (DSD) issues COSAs based upon representations provided by an
independent professional engineer. The Municipality of Anchorage is not responsible for errors or
omissions in the professional engineer's submittal.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
Development Services Department i Phone: 907-343-7904
On -Site Water & Wastewater Sectio Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 017-422-20
Complete legal description BONNIE VIEW LOT 11
Location (site address) 12720 NEHER RIDGE DRIVE ANCHORAGE, ALASKA 99516
Current property owner(s) MATTHEW & ASHLYN HALL — Day phone
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: Z Private Well E] Private Well serving 2 dwelling units
El Private Well serving 3+ dwelling units El Community Well or Public
R Water Storage
4. TYPE OF WASTEWATER DISPOSAL: E Private Septic F] Private Septic serving 2 dwelling units
r_1 Holding Tank F1 Community Septic or Public Sewer
5. SEPTIC TANK: R Steel Z Plastic R Concrete F] Fiberglass
Age 4 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: R AWWTS R Bed E] Deep Trench Z Wide Trench R Seepage Pit
Waiver request for:
Expedited review requested: n
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee
Date of Payment zz'za
COSA # C"
Waiver Fee $
Date of Payment
Waiver #
COSA Appliration.doc
COSA Checklist.docx
COSA Checklist
Legal Description: BONNIE VIEW LOT 11 Parcel ID: 017-422-20
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled UNK Total depth UNK ft
Cased to UNK ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 33 in.
Date of flow test for COSA 3/3/25
Static water level at beginning of test 62 ft.
Well production at time of test 1+ gpm
Water storage tank volume None gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate 1.39 mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by Date 3/3/25
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank 60”
Date of pumping 3/3/25
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) 10/26/21
ALL standpipes present per record drawing
Total measured depth from existing grade 5.3 ft (max)
Measured depth to pipe invert from grade 3 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective. (ED)
If not, state depth into effective The S Trench
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 3/3/25
Results Pass (Only the Southern trench tested)
Fluid depth prior to test 7 in
Water added 600 gal
New fluid depth 12 in
Elapsed time 1440 min
Final fluid depth 6 in
Absorption rate 600 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 24 in (MOA 2’ ED)
Effective depth used 6 in (Final Fluid Depth)
Effective depth (ED) remaining 18 in
Comments/Deficiencies: Approximate total measured depths from existing grade. Directly tested only the bottom southern trench of the 2021
3-trench system. The upper trench was mainly saturated & the middle trench pipes were buried but uncovered & found to have 1.6’ ED & was dry.
The 2021 system (3 trenches) seems all connected & only a CO & MT was uncovered in the middle trench. The 1996 nonconnected inactive / resting
field in the MOA docs is below grade & are present but was not located. See attached photos.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 04/07/2025
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
04/07/25
20
2
1
S
O
U
T
H
E
R
N
T
R
E
N
C
H
20
2
1
M
I
D
D
L
E
T
R
E
N
C
H
JU
N
E
1
3
,
2
0
2
4
P
H
O
T
O
19
9
6
R
E
S
T
I
N
G
RE
S
E
R
V
E
2
TR
E
N
C
H
E
S
UP
P
E
R
2
0
2
1
T
R
E
N
C
H
20
2
1
S
Y
S
T
E
M
H
A
S
3
T
R
E
N
C
H
E
S
UP
P
E
R
,
M
I
D
D
L
E
&
S
O
U
T
H
E
R
N
L
O
W
E
R
20
2
1
3
-
T
R
E
N
C
H
S
Y
S
T
E
M
UP
P
E
R
N
O
R
T
H
T
R
E
N
C
H
20
2
1
L
O
W
E
R
SO
U
T
H
E
R
N
TR
E
N
C
H
20
2
1
M
I
D
D
L
E
TR
E
N
C
H
DU
G
U
P
C
O
&
M
T
O
F
M
I
D
D
L
E
T
R
E
N
C
H
19
9
6
S
Y
S
T
E
M
2
R
E
S
T
I
N
G
/
R
E
S
E
R
V
E
TR
E
N
C
H
E
S
N
O
T
C
O
N
N
E
C
T
E
D
BU
R
I
E
D
P
I
P
E
S
MA
R
C
H
3
,
2
0
2
5
P
H
O
T
O
SE
P
T
I
C
T
A
N
K
&
D
I
S
T
B
O
X
Certificate of On -Site Systems Approval
Parcel I. D. 017-422-20-000
1. GENERAL INFORMATION
Expiration Date: 020 Q a
Complete legal description Bonnie View Subdivision Lot 11
Location (site address) 12720 Neher Ridge Drive
Current property owner(s) David Andersen Day phone 907-250-3741
Mailing address PO Box 111245
Real estate agent Kameron Draper Day phone 907-301-0208
2. TYPE OF DWELLING:
R Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
0
Private Septic
FI
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: _ Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ a 0U Waiver Fee $
Date of Payment 1 a 0 a o� l Date of Payment
Receipt Number o y a 5 0 b Receipt Number
COSA # C) 5 C �2 116 S ( Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm Phone 907-250-3741
Address
Engineer's Printed Name David Andersen Date 11-23-21
*.'"! 1 M t
�+ OF A4.
6. DSD SIGNATURE
System #1 Approved for 4 bedrooms;+7m DavidL.Aadersen
Ir C. C£4350 �+++
System #2 Approved for bedrooms ��#�`��F •1.1-23-21.. ����i
Disapproved l # %%sslo ~~-.
Conditional approval for bedrooms, with the following stipulations:
By Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
Legal Description: Bonnie View Subdivision Lot 11
If more than 1 septic system on lot: COSA Checklist #
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled 9-1995
Total depth 335 ft
Cased to 4W ft unk—d)pr n
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) 24 in.
Date of flow test for COSA NA
Parcel ID: 017-4222-000
of Structure served by this system
Well production at time of test 1+ gpm
Water storage tank volume 40 gallons
Well disinfected for coliform test? ❑ Yes ❑ N
❑ Coliform bacteria is Negative
Nitrate 3.35 mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by Alaska Testlab
Date of Sample 11-9-21
Static water level at beginning of test 17 ft.
Comments No well log avaliable. Flow Test performed October 1995
B. TANK DATA
Age of tank(s) New years
Tank type/material Poly
Measured operating fluid level in septic tank New
❑ Standpipes/foundation cleanout per record drawing
Date of pumping New
D. ABSORPTION FIELD DATA
Which system tested (date installed) New
❑ ALL standpipes present per record drawing
Total measured depth from grade 5.0' ft (max)
Measured depth to pipe invert from grade 2.1 ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments:
Adequacy test date New
Results EJPass For bedrooms
Fluid depth prior to test in
Water added gal
New depth in
Elapsed time min
❑ Code -required soil cover over field Final fluid depth in
❑ System presoaked Absorption rate gpd
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months)
date of test)
Gallons introduced gallons If yes, enter date
Comments/Deficiencies: Four Trenches were constructed with 2" of board foam insulation before cover was placed. The 5th trench has T of fill cover.
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
M✓
Yes
Community Sewer Manhole/Cleanout > 100'
Q✓ Yes
if No
ft
M Yes
if No ft
Neighboring Tank > 100' F71 Yes
if No
ft
Private Sewer/Septic Line > 25' Q Yes
if No ft
Absorption Field on Lot? 100' [Z] Yes
if No
ft
Holding Tank > 100' Yes
if No ft
Neighboring Absorption Fields > 100'
0✓ Yes if No ft
Water Main > 10'
Animal Containment > 50' 0 Yes
if No ft
M Yes
if No
ft
F✓ Yes if No ft
Water Service Line > 10'
M
Yes
if No
Manure/Animal Excreta Storage > 100'
If septic tank is under driveway comment below
Community Sewer Main > 75' ✓� Yes
if No
ft
0 Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
M✓
Yes
if No
ft
Surface Water > 100'
Q✓ Yes if No ft
Property Line > 5'
✓]
Yes
if No
ft
Wells on Adjacent Lots:
Q
Absorption Field > 5'
if No
Yes
if No
ft
Private Wells > 100'
0✓ Yes if No ft
Water Main > 10'
ft
Yes
if No
ft
Community Wells > 200'
F✓ Yes if No ft
Water Service Line > 10'
M
Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
El
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
M
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
Q
Yes
if No
ft
Private Wells > 100' U✓ Yes if No ft
Water Service Line > 10'
Yes
if No
ft
Community Wells > 200' Q Yes if No ft
Surface Water > 100'
✓0
Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
l certify that l have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
,�,�►``4N~OF A% t t �t
•. .� ......... L, t�
00
p David L. Andersen ct,�
CE -9150
.) l: 23-2t.,'`�,�
dtt t r:titis0►�,��•.
SGS Ref.#
Printed Date/Time 11/17/2021 16:56
Collected Date/Time 11/09/2021 16:20
Received Date/Time 11/09/2021 16:57
Technical Director Stephen C. Ede
1217412001
Client Name
Residential Testing - Cash Account
Project Name/#
12720 Neher Ridge Dr
Client Sample ID
12720 Neher Ridge
Matrix
Drinking Water
Sample Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Microbiology Laboratory
E. Coli Negative 1 100mL SM21 9223B
Total Coliform Negative 1 100ml, SM21 9223B
A 11/09/21 M.A
A 11/09/21 M.A
2 of 5
n
SGS Ref.#
1217643001
Client Name
Residential Testing - Cash Account
Project Name/9
D. Andersen -12720 Neher Ridge
Client Sample ID
12720 #1 92
Matrix
Drinking Water
Sample Remarks:
Printed Date/Time
Collected Date/Time
Received Date/7'ime
Technical Director
12/02/2021 16:50
11/23/2021 13:49
11/23/2021 14:18
Stephen C. Ede
Allowable Prep Analysis
Parameter Results LOQ Units Method Container 1D Limits Date Date [nit
Metals by ICP/MS
Arsenic ND 5.00
Waters Department
Total Nitrate/Nitrite-N 3.35 0.200
ug/L EI'200.8 A (<10)
mg/L SM21450ONO3-F B (<10)
11/24/21 11/29/21 DSD
11/24/21 EBI-!
2 of 6