Loading...
HomeMy WebLinkAboutBROADWATER HEIGHTS TR D BLK 1 LT 19Brocidwcxter Heights Block 1 Lot 19 Tract D #050-131-32 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP221447 Work Type: Septic Upgrade Effective Date: Expiration Date Tax Code Number: 05013132000 Site Legal Address: BROADWATERH EIGHTS TR D BLK 1 LT 19 G:0253 Site Mailing Address: 11643 BIRCH HILLS DR, Eagle River Owner: JUST MARK & CYNTHIA Design Engineer: C & M Engineering This permit is for the construction of: IR »>cnt - v DeI)artment 11/4/2022 11/4/2023 Lot Size in Sq Ft: 24493 Total Bedrooms: 4 CI Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: • A bedrock confirmation and groundwater monitoring testhole is to be placed near the southeast end of the proposed field prior to installation. Construction may proceed atyour own risk prior to 7 -day groundwater monitoring. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. �55U�/� jo C *f'i'1 C`)q,neerr'nGt Date: Issued By: vv Date: q&zL ROSH MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 050 131 32 Property owner(s) Mark Just Day phone Mailing address 11643 BIRCH HILLS DR Site address //TRAIL'S END RD Legal descriptio�(Sub'd., Block &Lot) BROADWATERHEIGHTS TR D BLK 1 LT 19 Legal description (Township, Range & Section) Lot Size 24,493 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (M all that apply) Absorption Field Initial ❑ Single Family (SF) ❑ (w/wo ADU) Septic Tank ElUpgrade 0 Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: NONE Distance: NA I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. C&M ENGINEERING (Signature of property owner or authorized agent) Permit/Rush Fees: q5 -s Date of Payment: !019.& 12 Receipt Number: Ott q31 % Permit No. 05P a a 1483 Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc C&M ENGINEERING SERVICES Ph: 907-854-5558 Municipality of Anchorage Onsite Water & Wastewater Program 4700 Elmore Rd Anchorage, Ak 99507 RE: Proposed Septic System for BROADWATER HEIGHTS TRACT D BLOCK 1 LOT 19 Dear Reviewer, The leachfield at the above referenced property appears to have failed. We are requesting approval to construct the alternate site drain field. There is a drainage swale more than 50’ from the proposed field location. Groundwater was found as shallow as 6’ on the site. The bottom of field will be at a max depth of 4’. Note that fill has also been added since the original field was constructed. There will be more than 3’ separation between the bottom of the field and the bedrock previously identified and more than 2’ separation to seasonal high groundwater. See attached soils log which shows additional fill placed at the leachfield location when compared to the ERES testhole. Note that the ERES testhole was excavated prior to the placement of several feet of fill at the reserve site. There has also been significant earthwork and drainage work on the property. An October groundwater reading revealed no groundwater at the leachfield location. This justifies not applying the 6’ December (4’ seasonal high) groundwater reading to the current design. The profile drawing for the original system shows the original leachfield compared to original grade. It appears that there was approximately 1’ of topsoil at that time as opposed to the 4’ of fill at the reserve site. The existing Advantex unit will remain and a diverter valve will be installed. The Advantex and tank is under or near a deck. The deck foundation does not impact the septic tank. The deck supports are not directly above the tank. A waiver is requested between the proposed field and a steep slope. The justification for the waiver is provided on the profile drawing. Our review of historic soils logs and soils logs on neighboring lots show that the native soils have a percolation consistently below 10 minutes per inch. Based on this the use of a 5 gpd/sqft application rate is justified, subject to visual confirmation of soil conditions during construction. If soil conditions change materially, an additional perc test will be performed. A gutter drain system appears to be a contributing factor in the failure of this field. The contractor must relocate the gutter drain so that it daylights more than 50’ from the fields. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221447, Deb Wockenfuss, 11/04/22 Our review of available documentation and field investigation show that this project will not adversely impact any nearby Wells, Wastewater disposal systems, replacement disposal sites, or drainage flowing onto and off of the subject property. Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854- 5558 or by email cgbalzarini@gmail.com with any questions or concerns. Sincerely, Charles Balzarini, PE 10/11/22 Residence: number of bedrooms 4 br Water usage/bedroom 150 gpd/br Water Usage 600 gpd system type: CONVENTIONAL type: Shallow Application Rate 5 gpd/sqft required absorption area 120 sqft trench width (W) 5 ft gravel depth (D) 1 ft below distribution pipe Min Required Length: 24 ft Use Length: 40 ft Max ex depth 6 ft Calc By: CGB Date: 10/15/2022 C&M ENGINEERING SERVICES 907-854-5558 Septic Design Calculations Broadwater Hts TrD Lt19 Block 1 RESIDENCE/LOT INFO DRAINFIELD Only Bottom of field used for absorption area calculation. Based on historic testhole **DIMENSIONS FOR REFERENCE ONLY. SEE PLANS FOR DIMENSTIONS TO BE USED IN CONSTRUCTION** To bottom of sand see plans for thickness Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221447, Deb Wockenfuss, 11/04/22 CHARLES G BALZARINI CE-13854R EGISTEREDPROFE S S IO N ALENGINEER8/5/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221447, Deb Wockenfuss, 11/04/22 CHARLES G BALZARINI CE-13854R EGISTEREDPROFE S S IO N ALENGINEER10/12/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221447, Deb Wockenfuss, 11/04/22 i) Municipality of Anchorage Development Services Department On-Site Water and Wastewater Section 4700 Elmore St. P.O . Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Soils Log - Percolation Test ,: .- . ._...,'- V').. · .,-,, . .. , ·..CE-13854 .·~-· · t~;~Yl(l'?t.~ 'v~ ··'I PRQFESS'O·._ ..' ' .. .. . Performed For:MAR~J'v5 r Date Performed : __ 9--'-/-"'J-_9'fiL.L/+~~'2 ___ _ Legal Description :B/.<0,40 h/A-[EP--, Hrs ?J' t..17 Township , Range, Section: ------------ 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- Depth (Feet) ~--1 ,.,< ~ ...,. ' , (_ I (., ( Slope WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth to Water After Monitoring? Date: Reading Date s L 0 Mf} N'/ ,4 N/A l&rl 5~ p E O"J~ Gross Time PERCOLATION RATE - (minutes/Inch) Site Plan Net Time Depth to Water PERC HOLE DIAMETER TEST RUN BETWEEN ___ FT AND ___ FT coMMENTs ~r2.. lYiZ!>{.1A1 1:>wA ,6~ M&..v:z:raA: c,µ'--i Net Drop PERFORMED BY: C · /2; r]- L-2rA-~ ,J::',v...C I c:::~ RTIFY THAT THIS TEST WAS PERFO RMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE . DATE : l(}/µ//lrz Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221447, Deb Wockenfuss, 11/04/22 Permit No. SW060031 Page 2 of 2 Municipality of Anchorage DEVELOPMENT SERVICES DEPARTMENT Y ON—SITE WATER & WASTEWATER PROGRAM T ` 4700 SOUTH BRAGAW STREET P.O. BOX 196650, ANCHORAGE, AK 99519-6650 0 On—Site Wastewater Disposal System and/or Well Inspection Report tion: BROADWATER HEIGHTS LOT 19 BLOCK 1 TRACT D C(G,1k, 3;;% �\ SWING TIES _O r ION ")'a �= C- 13 D T— .4 111.: �tl a /k . r , !(f c r sC,Qw Co ' Lot 20 (VACANT) 51 e c1 ' 1 C f 050-131-32 o•• Lot 10 F SCALE 1'-40• Lot 11 (VACANT) /G r 3 01,, :9 y 0 - CLEANO WEU. MONITOR TUBA ROX. KEYBOX AnON 95C41•41i; TOP or FILTER POD ASSUMED ELEVATION • 100' ELEVATIONS OCT TO SCALE) 1' FILL MT -2 SEPTIC AREA c, Lot 18 (COMMUNITY WATER) 6/27/2007 ORIGINAL GROUND LEVEL ATS 9 .5 II= I kir NSULATION ��956 90.5 re �Lt' GRA VEL 95.7 °o . •, •o • P e 94.5 139. 91.6 95.6 BOTTOM OF T.H. 91.6 500 GAL AUDVANTEX TH^L INSULATION 3' 94 ENGINEER'S SEAL 'rMunicipality of Anchorage' e .a • 1 : -- Development Services Department ")" Building Safety Division �� ,/ ;, . On -Site Water and Wastewater Program, 4700 Bragaw St. - P.O. Box 196650 Anchorage, AK 99519-6650 Page www.ctanchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SW060031 PID Number. 050-131-32 1 of 2 Name WAYNE AND CARMEN DEVORE Wastewater System: C4 New 0 Upgrade Addrasr. 11643 BIRCH HILLS DRIVER ABSORPTION FIELD Pates Number a � ® Deep Trench a Shaba Trench o Bed D Low D Other ooms. 351-5881 LEGAL DESCRIPTION Sal R" "° 6 GPDPFP TdrD.pn from «a at Ora 2 FI. Block: Lot sWdmlon: 1 19 BROADWATER HEIGHTS, TRACT D DOOM to PIM bonwm from anginal aids .9 n. Gavel depth bream pat: 1.1 FI Township.Rage'. Sabo,: L 41 FM .ddb above wane( pad.: 2.1 FI. Gravel Larpm: 40 Fl. Well: ■New Upgrade Gravel faddy 5 Ft. Number taw: Distance between ear Ft or 1 ClassM1rnwn (Private. A e. C): PUBLIC WATER Taal Dept. Ft. Cased to Ft Taal PIM Mauer ASTM 3034 .bnrpbon area 167 FI' Dater Date Droned Stap Water Level: Ft Installer GUARANTEED SERVICES Dal. Installed: 8/7/2006 'lad GPM Pump Sat at FI. Comb Hecht Above Gond. Ft TANK SEPARATION DISTANCES ® septic ❑ Holding ❑ S.T.E.P. a Other. ADVANTEX To From Septic Tank Absorption Field Lift Station Holding Tank >ubl}HPrlvate Sewer Line M'r"')ra" '• ANCHORAGE TANK C.Panly 1500 Ga. Wm — — — — — Material STEEL Number o Compartments. 2 eurfnwatr. +100' +100' — — LIFT STATION Latina 3'• 8' — — 5�e. NO LIFT Gel Manufacturer. Fwndaten +5' +10' — — 'Pump on' level at in 'Pp per level at. H NO water a k Cvlan Drrn +50' +50' — — Pump Make a Model Eecu al bMctons pbomed w RISING SON ELECTRIC RamaSEE • • SEE ATTATCHED WAIVER REDDEST BENCH MARK Locetlon and Desa,Mm. TOP OF ADVANTEX FILTER POD Assured Farallon. 100 FL Inspections performed by: CHARLES BALZARINI Dates: tat 8(7/2006 Ei)) r .1 .Q F„..A�� '` • j,I j � *,f,�lp � 26d 817/2006 Development Services Department Approval Conditional Approval Date: • ` /[/ ii % CHRISTOPHERR.WOOD . 1 CE:10387 A� "x'Gis A� Reviewed and approved by Date: (an. e04/06). Permit No. SW060031 Page 2 of 2 Municipality of Anchorage DEVELOPMENT SERVICES DEPARTMENT ON—SITE WATER & WASTEWATER PROGRAM 4700 SOUTH BRAGAW STREET P.O. BOX 196650, ANCHORAGE, AK 99519-6650 On—Site Wastewater Disposal System and/or Well Inspection Report Legal Description: BROADWATER HEIGHTS LOT 19 BLOCK 1 TRACT D SWING TIES ______A—.1 e0 c D 19.4' 19.4' 19]' 43 Lot 20 (VACANT) LS', N. Lot 10 'Os F 050-131-32 SCALE 1'-40' Lot 11 (VACANT) 153 ti - C O� - WELL `so - MONITOR TUBE y A°CATIONKEIBOX ..,--"-.- 4.-‘'‘ .,/ .tO.‘'‘� 1� INSULATION TOP OF FILTER POD I- ‘ SEPTIC AREA Lot 18 (COMMUNITY WATER) ASSUMED ELEVATION • 100' ELEVATIONS ORIGINAL GROUND LEVEL ATI 9•.5 (NOT TO SCALE) 1' FILL MT -2 NTH -1 NSULATION -0-95.6 90.5 94.5 89. BOTTOM OF T.H. 6/27/2007 Municipality of Anchorage Mayor Mark Minch P.O. Box 196650 • Anchorage, Alaska 9991!MW,.30 • Telephone (907) 34:14n01 • Fax (907) 343.8200 4700 nrngaw Street • Anchorage. Alaska 99507 utrtr.numIorg Building Safety Division July 12, 2007 Christopher Woods Eagle River Engineering Services P.O. Box 773294 Eagle River, AIC 99577 Subject: Waiver Request for Broadwater Heights Tr D Block 1 Lot 19 Waiver Request WR#: 070035 Parcel ID # 050-131-32 PERMIT # SW060031 Dear Christopher Woods: Your request for a waiver of the required 10 feet horizontal separation from the absorption field and septic tank to the property line has been approved. The approved separation distance is 2.0 feet. This waiver approval applies to the existing absorption field and septic tank to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, Jo.0.dall Civil Engineer On -Site Water & Wastewater Program Community, Security, Prosperity Municipality of Anchorage Development Services Department Building Safety Division On-Sitc Water and Wastewater Program 4700 bragaw Strcct P.O. Dox 196650 Anchorage, AK 99519.6650 www.ci.anchoragc.ak.us (907) 343-7904 Waiver Review Worksheet WR#: 070035 PID#: 050-131-32 HA/Permit# PERMIT # SW060031 Date Received: July 12, 2007 Legal Description: Broadwater Heights Tr D Block 1 Lot 19 Engineer. Christopher Woods Eagle River Engineering Services P.O. Box 773294 Eagle River, AK 99577 Applicant: Wayne Devote Waiver Requested: 2 foot horizontal separation from septic system to lot line waiver Criteria: Geology A. Water Table B. Soil Sorplion C. Permeability D. Water Table Gradient E. Horizontal Separation Total: Points: Waiver is Granted: X Waiver Is not Granted: Ust Conditions or Reasons for above: Date: 7/12/07 By: Joe Goodall Name of Reviewer Rec#: 96600 Amount: $175 Date Paid: 7/12/2007 Eagle River Engineering Services Christopher R. Wood, P.E. 10421 VFW Road Suite 201 (907) 694-5195 tel Eagle River, AK 99577-3294 (907) 694-3297 fax June 22, 2007 Dan Roth. Manager, On -Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Broadwater Heights Lot 19 Block 1 Lot Line Waiver Application Dear Mr. Roth: After receiving the certified as -built survey for the above referenced property, it was noticed that the septic tank and leachfield were installed too close to the lot line. Prior to the installation of all septic system components, the lot line was clearly marked, staked, and flagged by a licensed land surveyor. It appears that these markings were in error, causing the septic system components to be installed 2' closer to the lot line than intended. The purpose of this letter is to request a waiver for the separation distance between the installed Advantex tank and leachfield to the lot line. The distance we are requesting to be waived is for 3' lot line to septic tank, and 8' for the leachfield to lot line. The proposed site for the septic reserve will not have to be waived, as a distance in excess of 10' can be maintained. The proposed lot line waiver will have very limited impact on adjacent properties for the following reasons: 1. Several of the surrounding lots are on a public water system, thereby eliminating some 100' protective well radii. 2. Immediate neighboring septic systems are all +30' distance, or undeveloped. 3. Drainage will not be affected by this lot line waiver request. 4. The wastewatewater system is treated with Advantex technology, a MOA Category III treatment system. Any potential for contamination of drinking water sources or to the environment is extremely small while utilizing a properly maintained Category III system. WAIVER FEE: 1'-$5 PAYMENT DATE: tcin )b RECEIPT #: I ifito 3D \2003105.134 DEVORE WAIVER For the reasons listed above, we believe that granting this lot line separation distance waiver of 3', and 8' for the tank and leachfield respectively, will not impact adjacent properties' ability to support on-site septic systems and reserve sites. To our best available knowledge, granting of this waiver will not affect the function or longevity of neighboring septic systems. If you have any questions please call our office at 694-5195. Sincerely, EAGL ' Y • . i EEI2ING SERVICES ristopher R. ood, P.E. Principal \2003\05-134 DEVORE WAIVER • June 12, 2007 Guaranteed Services Wayne Devore 18139 Misty Fall Circle Eagle River, AK 99577 Rising Son Electric. Inc. 14916 Woodland Drive Eagle River. AIC 99577 (907) 622-6/// Re: 11643 Birch Hills Drive - Eagle River, AK 99577 - Lot 19 Block 1 Tract D Broadwater Heights Dear Wayne: The lift station at the above referenced property has been wired In accordance with NEC and State/Local codes. Thank you. Sincerely, /eon , ,Z 7. ,.cac, . Kevi Hornbuckle, Owner Administrator License Number 1284 Specialty Contractor License Number 27285 cc: file MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Mar 08, 2006 Expiration Date: Mar 08, 2007 Permit Number: SW060031 Parcel ID: 050-131-32 Legal Description: BROADWATER HEIGHTS BLOCK 1 LOT 19 TRACT D Design Engineer: 0848 EAGLE RIVER ENGINEERING SEI Site Address: 11643 BIRCH HILLS DRIVE Owner Name: WAYNE DEVORE Lot Size: 24493 SO. FT. Owner Address: 18139 MISTY FALLS Total Bedrooms: 4 Permit Bedrooms: 4 EAGLE RIVER , AK 99577 - This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank O Holding Tank ❑ Privy fl Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). g, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -THE UPPER SIX INCHES OF THE MOUND SYSTEM MUST CONSIST OF TOP SOIL AND THE MOUND MUST BE VEGETATED SUFFICIENTLY TO PREVENT EROSION. Received By. Issued By 7 Date 3I \O(/ Date: 3A*O Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEPTIC/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 050— 131- 32 Property owner(s)J/4 YAM. b:VO RL- Day phone 3 S/- Sg% I Mailing address /4 13°1 M157 y 1=4 c.c.s 6 2 /4 c Zip Code Q i S 77 Site address (l�(-l3 eB\ vc'n 4 \t i\s Dnv6 Zip Code Legal description (Sub'd, Block & Lot) 13RO46WATM ►WS. LOT 19 i R.Q. Cu. .. Legal description (Township, Section & Range) T PYA/ 17_2 i -J 5CC, 1 Y Lot Size a1, 461(Sq. Ft. Number of Bedrooms THIS APPLICATION IS FOR (Nall that appy: THIS APPLICATION 1S AN: Absorption Field Septic Tank Holding Tank [g' pi Upgrade ade 0 Renewal Privy ❑ Private Well 0 Water Storage ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family D elli g and is iq accordance with applicable Municipal Codes. 0 (Signature of property owner or authorized agent) Permit/Rush Fees: Lf l,D '610 Date of Payment: 9 (o 1A Waiver Fees: /15 ED Date of Payment: 3/g t Receipt Number: q51,12 Receipt Number: 7-r 3E3 (Rev. 11/05) Eagle River Engineering Services Christopher R. Wood, P.E. 10421 VFW RD. Suite 201 (907) 694-5195 tel Eagle River, AK 99577 (907) 694-3297 fax January 12, 2006 Dan Roth Manager, On -Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Broadwater Heights Lot 19 Tract D Block 1 Narrative & Permit Application, Vertical Separation Distance Waiver request. Dear Mr. Roth: Eagle River Engineering Services (ERES) was contacted by the owner of the property noted above to design a septic system to serve a new 4 bedroom house. A test hole indicated free - draining soils from 1 to 7 feet below ground surface, with bedrock at 7 feet. The water table was monitored for one week and was measured to be 6' below ground surface. The homeowner wishes to utilize Advantex technology to minimize the size of the leachfield, and also wishes to construct the alternate site at the time of installing the primary system. We are requesting a waiver from bottom of leachfield to bedrock of 5 feet. We feel the fractured nature of the bedrock in addition to the quality of the effluent provided by the Advantex technology will be protective of human health. In addition, we are requesting a waiver for 4 feet from the bottom of the leachfield to ground water. ERES believes that positioning the sewer rock just below the topsoil layer, with the sides and bottom of the sewer rock surrounded by native free -draining soil is preferable to being elevated with a sand layer, with the sides of the drain rock confined by visqueen or topsoil. We believe there to be a lesser chance of the effluent saturating the topsoil layer, or potentially daylighting if this vertical separation waiver is allowed. The topography at the leachfield site is a consistent 15%-20% toward the southwest. The lot will be connected to the public water supply. A keybox already exists in the southern corner of the lot. The proposed 4 bedroom septic system and well will have very limited impact on adjacent properties for the following reasons: 1. The surrounding lots are well laid out, so there is room for wells, septic systems and alternate sites. 2. Immediate neighboring septic systems are all +20' distance, and no private (or community) wells within 100' of the proposed septic system. 3. Drainage will not be affected and is not a major consideration in our design. X2003\05-I34SEPTICNARRATI VE Installation of this 4 bedroom Advantex septic system, to our best available knowledge, will not adversely affect the wells or septic systems or reserve areas on adjacent lots. If you have any questions please call our office at 694-5195. Sincerely, EAGLE RIVER ENGINEERING SERVICES Christopher R. Wood, P.E. Principal \2003\05-I 34SEPTICNARRATI VE NEIGH S .S�P11c AREA 33' / i Lot 20 VACANT) Tb• Os Lot 10 BULL RUN DIVERTER VAL PROPOSED HOUSE Lot 11 (VACANT) 121 • 0 TEST HOLE MONITOR TUBE SEWER CLEAN OUT WELL EASEMENT PROPOSED LEACH FIELD EXISTING LEACH FIELD DRIVEWAY O. 1 ‘SEP11C AREA Lot 18 (COMMUNITY WATER) 1. NO KNOWN SURFACE WATER, OTHER THAN SHOWN 2. NO KNOWN CURTAIN DRAINS 3. NO SEPTICS WITHIN 30' UNLESS NOTED 4. NO WELLS WITHIN 200' UNLESS NOTED 5. NEIGHBORING LOTS SERVICED BY COMMUNITY WATER WELL/SEPTIC SITE PLAN LEGAL: BROADWATER HEIGHTS, LOT 19, BLOCK 1, TRACT D OWNER: WAYNE DEVORE CONTRACTOR: GUARANTEED SERVICES JOB# 05-134 DATE: 1/20/2006 SCALE 1"=50' AEAGLE RIVER ENGINEERING SERVICES P.O. Box 773294 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX:. (907) 694-3297 et 9F: 114,;414 'CP,i, •• `s' 4 r r• /Arm .CHRISTOPHER R. WOOD. i/ v. a, CE -10387 , • `41�edt- I1 ILPRertssiot4 ,*t • • • Lot 20 (VACANT) BULL RUN DIVERTER VAL R2 $2� SEPTIC AREA,/ G N STALL NEW 15Q0 GAL ADVANTEX W/AX-20 FILTER POD Os Lot 10 PROPOSED HOUSE i 3 (4P Itt 5 0 INSTALL N W \RESERVE SITE 5'X40' DRAINFIELD 0. Lot 11 (VACANT) Lot 19 ® — TEST HOLE • — MONITOR TUBE o — SEWER CLEAN OUT 4 — WELL -1-1"309-tP5 5a \\ C.\ f SEPTIC AREA Lot 18 (COMMUNITY WATER) 30 1. NO KNOWN SURFACE WATER +100'. — — —\ EASEMENT 2. NO KNOWN CURTAIN DRAINS PROPOSED LEACH FIELD 3. NO SEPTICS WITHIN 30' UNLESS NOTED — EXISTING LEACH FIELD 4. NO WELLS WITHIN 200' UNLESS NOTED DRIVEWAY 5. NEIGHBORING LOTS SERVICED BY COMMUNITY WATER WELL/SEPTIC SITE PLAN LEGAL: BROADWATER HEIGHTS, LOT 19, BLOCK 1, TRACT D OWNER: WAYNE DEVORE CONTRACTOR: GUARANTEED SERVICES JOB# 05-134 DATE: 1/10/06 SCALE 1"=40' AEAGLE RIVER ENGINEERING SERVICES P.O. Box 773294 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX: (907) 694-3297 _4 OF.qz, 10 ,:\N•-.••• 1• •'. •..... $ ' •.CHRISTOPHE' R. W000.. �/ Te r,• CE -10387 ` i ,1�,�o ' 8,: Eagle River Engineering Services Christopher R. Wood, P.E. 10421 VFW RD Suite 201 (907) 694-5195 tel Eagle River, AK 99577-3294 (907) 694-3297 fax SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM — MOA CERTIFIED INSTALLER LEGAL: Broadwater Heights Lot 19 Tr. 1) Block 1 January 12, 2006 A. GENERAL 1. The septic plan is for a 4 bedroom single family residence only. 2. The drawing and or site plan shall be a part of this specification. 3. All materials and workmanship shall meet the Anchorage Department of Health and State Department of Environmental Conservation requirements. 4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. 5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage, Department of Environmental Conservation requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi -family wells. A licensed surveyor should locate any utility easements and exact 100' radius from the existing and neighboring on-site wells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. Any remaining open test hole excavations shall be filled and monitor tube removed. 13. ADVENTEX SYSTEM AND SEPTIC TANK 1. Septic tank shall be a fiberglass or steel 1500 -gallon tank capacity of MOA approved construction for use with Advantex system. Install as per current manufacturers recommendations for conditions in Alaska. 2. Install one AX -20 filter pod over septic tank capable of treating 450 gallons per day of waste flow. 3. If gravity feed can not be achieved, Install Orenco 24" pump basin P13-2496 outside septic tank, with OS1 pump model P30-05 and controls to allow 23 gallon dosing of septic leachfield. Set pump float to 13.5" above pump, timer for 1 minute dose time. Controls to be installed to MOA code by licensed electrician familiar with OSI applications. Controls to include a dedicated phone line and web based monitoring system. 4. A municipal inspection report or receipt from a licensed electrician shall be provided to the engineer verifying lift station wiring to all applicable codes. C. DRAINFIELD 1. The drainfield is to be located as shown on the site plan. 2. The total depth of the initial drainfield excavation is to be at a maximum 2' deep, relative to existing ground elevation and end in native sandy GM -type soil. The excavation shall remove the topsoil layer. The bottom of the excavation shall be level, plus or minus 1.5". 3. An eighteen -inch layer of sewer rock is to be placed over the sand layer (fifteen inches if lift station is utilized). The 4" effluent piping (1' if lift station is required) is to be buried within the gravel layer with 2" of gravel cover over the piping. 4. The completed drainfield gravel and piping is to be covered with typar fabric material. 5. Soil or combination of soil and extruded board insulation to a depth of 3' or equivalent is to be placed over the bed. Mounded side slopes on uphill side and ends are not to exceed 3:1. 6. The septic tank and leachfield must not be closer than 100' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. \2003\05-134-Advantex spcc SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM—MOA CERTIFIED INSTALLER LEGAL: Broadwater Heights Lot 19 Tr. D Block 1 January 12, 2006 Continued: RECOMMENDED LEACHFIELD DIMENSIONS TOTAL DEPTH = 2' maximum GRAVEL DEPTH = 1' under effluent pipe, 2" over pipe (1.25 feet total) DRAINFIELD LENGTH = 40' DRAINFIELD WIDTH = 5' SOIL RATING = 6 OPD/f12 DEDROOM CAPACITY = 4 EFFLUENT PIPE (GRAVITY)= 1 run of 4" perforated pipe meeting MOA specifications. EFFLUENT PIPE (IF LIFT STATION IS REQUIRED) = 1.25" from pump basin to leachficld then 1" manifold to I" PVC with 1/8" holes oriented down spaced at 1.5' OC. 2 pipe runs in leachficld 2' between pipes 1.5' from sidewalls and end of trench. SEPTIC TANK = 1,500 Gal Advantex compatible tank w/ AX20 filter pod and lift basin Twenty-four (24) hours notice required for all inspections \2003\05-134-Advantex spec ti %%%%%F �,h� EAGLE RIVER ENGINEERING•••1/4"+-#0 10421 VFW RD, SUITE 201 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX: (907) 694-3297 SOILS LOG - PERCOLATION TEST PERFORMED FOR: WAYNE DEVORE DATE PERFORMED 12/19/2005 LEGAL DESCRIPTION: BROADWATER HEIGHTS LOT 19, BLOCK 1 TEST HOLE # 1 SLOPE 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 DEPTH (FEET) Mr • • .o • • TOPSOIL ROCKY OM N1TH SAND AND BOULDERS Y 1120 SEEP BEDROCK WAS GROUND WATER ENCOUNTERED? IF YES AT WHAT DEPTH YES 6' DEPTH TO WATER AFTER MONITORING? 6' ?; •.CHRISTOPHER R. V1000•' Ault'/ I• # �, CE -10387 . • `F': 04 to ' 4 4',%; ; I`''.? TOWNSHIP RANGE SECTION T14N,R2W,SEC1 SITE PLAN(NOT TO SCALE) SLOPE 57• 1 DATE: 12/27/2005 PERC TEST RESULTS READING DATE GROSS TIME NET TIME DEPTH TO WATER NET DROP 1 12/1912005 121:56 0 1' 6 0 2 12/19/2005 11:06 10' 1' 9 1/4 3 1/4 3 12/19/2005 11:07 0 1' 6 0 4 12/1912005 1 :17 10' 1' 9 1/8 3 1/8 5 12/19/2005 11:18 0 1' 6 0 6 12/19/2005 1 :28 10' 1' 9 3 PERCOLATON RATE• 3.33 (N WNCH) PERC HOLE CAA IETER•6 TEST RUN BETWEEN 1 FT AND 2 FT COMMENTS. SOILS LOGGED BY: CHARLES BALZARINI PERCOLATION TEST BY: CHARLES BALZARINI 1 C6'&S A CERTIFY THAT THIS TEST WAS PERFORMS IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: /Az _0 6 Typical Liquid Level Positions for Residential AdvanTef Treatment System with MVP Control Panel kid P4103 dui VP& welds'm 'mai/ : alte"PY NAlPFNU q IIJONSOd Pa1 Wen Mal Mt OJ.J APES M/7Vf spe Y•A.ba..IW "epi &imbed a / £ / Away 'ae Pros,* OrN o.7 Ai awe 1j 11 'Ae Mbrp ►•a.4 .ase e4I O *paw ..p :RTar — 17('ICr1 IKTOOt — re9Y(TL row se crf f 11 i K .N?sie h 8 8 8 53 3o►'(H01) PeeH oiweuAO le;cl 8 R N 0 YI 0 a r 0 Z * SWIM' El w eiri000e:.400 0 h ! ! 1 Effluent Pumps _P20, PJ18 Series 12 hp tot-12 hp I ! i•I —r -1 ii 1 1, -I— I. 11 {— 1 fi v I I •I ' 0 _ k. w: N -_ N N R �; �` a 8 8 8 53 3o►'(H01) PeeH oiweuAO le;cl 8 R N 0 YI 0 a r 0 Z * SWIM' El w eiri000e:.400 0 h EAGLE RIVER ENGINEERING SERVICES P.O. Box 773294 Eagle River, Alaska 99577 (907)694-5195 ERES Project No.: 05-134 Calculated By: CB Date: 12/27/2005 Legal: BROADWATER HEIGHTS LOT 19 BLOCK 1TEST HOLE 1 Single Family 4 Bedroom Dwelling Shallow Trench Subsurface Wastewater Disposal FieId Water use at 150 gallons per bedroom = Percolation rate = Wastewater application rate = Required absorption area = Trench width (W) = Gravel depth (D) _ Required length = Shallow trench factor • Shallow trench factor = (W + 2) / (W + 1 +2 D) Shallow trench factor = 1.00 Total Excavation Required length = 05-134 AdvantexdrainfieldCalc.xis 1 600 gallons 3.33 minutes per inch 6 gallons per day per square foot 100 square feet 5 feet feet/oi G, W. Required absorption area / W 2..o Fr WAVER Depth = feet aGOAAE'Sieb 2 feet >A5 40' 2:17 PM12/27/2005 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Eagle River Engineering Services Legal description: Broadwater Heights Subdivision. Tract b. Block 1. Lot 19 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. ❑ Additional soils information needed. _ ❑ Water monitoring results inadequate. ❑ Discrepancy in information submitted. _ O Topographic information missing or inadequate. ❑ Incomplete; missing ❑ Incomplete; missing ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. _ O Proposed system too deep for soils information submitted. ❑ Well log required. ❑ Omission in narrative. ❑ Insufficient fill over tank or field._ ® Other. 1.) Need to pay waiver fee for vertical separation distance from bottom of absorption field to groundwater and bedrock; 2,) Please verify effective depth; and 3.1 Property owner needs to sign maintenance agreement• to Ditask/ e- c r ,(,ion ays races., -ccar 5Arao.rn \o Name of reviewer: Julie Makela. P.E. Date: 1/20/2006 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK PERFORMED FOR: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG – PERCOLATION TEST lecil lea/ XSOILS LOG DATE PERFORMED: ❑ PERCOLATION TEST z/44,441 LEGAL DESCRIPTION: "`—' / e1 , J%Z%e ch-Li'h/ ij/ Mc-71- nFaru. SLOPE SITE PLAN 3%L 7y-'3._ O y /y,� 10 11 12 13 14 La/%?i OF /e. 15 -,�,`" ,4j ' s: , a 16 0 4, A /14P.4. •.•:.": 17 18 1 • Robert A. Sh. r 4v a1 *%, No. 1457. 19 tiro :•.,• 0,1 z•o4,'ry 20 COMMENTS PERFORMED BY: 72-008 (6/79) 1 WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? J L O E A i7" 1 0 Reading Date Gross -Time Net Time Depth to Water Net Drop / f i 014/ ifj/ /4 it MUNICIPALITY CF ANCHORAGE DEPT. OF ENVIRONMENTAL AEACTH I ' CTECTION PERCOLATION RATE TEST RUN BETWEEN (minutes/inc AjG 2 4 1981 :La S Enginec•ritig CERTIFIED B FT AND FTRECEIVED Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING (D5f 1.;1ato5- COSA # 05C - Parcel I.D. 050-131-32 1. GENERAL INFORMATION Complete legal description Broadwater Hts, Tract D, Block 1, Lot 19 Expiration Date: g / 6 Location (site address) 11643 Birch Hills Drive, Eagle River, AK 99577 Current Property owner(s) DEVORE WAYNE Mailing address Lending agency Mailing address same Day phone 830-8263 Day phone Real Estate Agent Ed Erickson Mailing Address Keller -Williams Day phone 227-5275 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Public Water System Well 4 TYPE OF WASTEWATER DISPOSAL: ❑ Individual On-site ❑ Individual Holding Tank ❑ Community On-site Public Sewer The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm NorthRim Engineering Phone 694-7028 Address PO Box 770724, Eagle River Engineer's Printed Name Steve Eng Date 8/22/2012 Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic ssy®)�e nes are subject to these various and dynamic characteristics and are outside the control of the ,� or �dt A�� evaluator of the well and septic system. • -v.. ,,........ qui 9, k ./p Tao °. t 400 ..°Y9 0 B 5. DSD SIGNATURE /, 1... --Approved for 14 bedrooms. to ° Steven W. Eng it 11, 2 Disapproved. Q F9F °e �tJ Conditional approval for bedrooms, with the following stipulations. :49=(4, k\TY tOFf f mr r1 ON-SITE WATER AND WASTEWATER g c PROGRAM h Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory By: (Rev. 11/05) Arsenic Advisory J4 osjjjc' Maintenance Agreements Supplemental Engineer's Report Other /i(% 7C)Od Original Certificate Date: -C-P-- Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Broadwater Hts, Tract D, Block 1, Lot 19 Parcel ID: 051-131-32 A. WELL DATA — Public Water Well type na If A, B, or C provide PWSID # _ Well Log (Y/N) na Date completed na Sanitary seal (Y/N) na Wires properly protected (Y/N) na Total depth na ft. Cased to na ft. Casing height (above ground) na in. FROM WELL LOG AT INSPECTION Date of test na na Static water level na ft. na ft. Well production na g.p.m. na g.p.m. WATER SAMPLE RESULTS: Coliform NA colonies/100mL Nitrate NA mg/L Arsenic: na mg/I Date of sample: na Collected by: NA B. SEPTIC/HOLDING TANK DATA Tank Type/Material Advantex/Steel Date installed 8/7/06 Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) Y Date of pumping Maintained By Anchorage Tank Pumper Anchorage Tank C. ABSORPTION FIELD DATA Date installed 8/7/06 Soil rating (g.p.d./ft2 or ft2/bdrm) 6 System type trench Length 40 ft. Width 5 ft. Gravel below pipe 1.1 ft. Total depth 4.5 ft. Eff. absorption area 167 ft2 Monitoring tube Y Depression over field N Date of adequacy test 8/16/12 Results (Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test 2 in. Water added 600 gal. New depth 3 in. Elapsed Time: 60 min. Final fluid depth 2 in. Absorption rate >= 600 g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed na Size in gallons na "Pump on" level at na in. Datum na "Pump off' level at na in. Cycles tested na E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot na Absorption field on lot na Public sewer main NA Manhole/Access (Y/N) na High water alarm level at na in. Meets alarm & circuit requirements? na On adjacent lots na On adjacent lots na Public sewer manhole/cleanout NA Sewer /septic service line na Holding tank na Animal containment areas na Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 31" Water main 10'+ Water service line 101+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 8'+ Building foundation 10'+ Water Service line 10'+ Surface water 60'+ Absorption field 5'+ na Surface water 60'+ Water main 101+ Driveway, parking/vehicle storage 10'+ Curtain drain (None Known) Wells on adjacent lots 100'+ F. COMMENTS *Waiver Request Attached To Surface Water. Previous waivers granted by MOA for groundwater/bedrock And Lot Line. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Steve Eng Date 8/22/2012 PR•OF'A�gs'$d1 el co e i* •r49L 0 `mra rrr Steven W. Eng w tP ttal % PE 6 56 '•trri %r�1t��• COSA Fee $490.00 Date of Payment Receipt Number o-4SdG G (Rev. 11/05) -1ac Waiver Fee $ (O0 Date of Payment sit a 311a, Receipt Number 0454 3 C- REL6RT/F/ED,' 8-24-20)2 ADDEO S72v'Q$/ cam iew5 IANDS[Ap1 LOT 20 ACCESS PANEL TO SEWER SYSTEM SEPTIC MANHOLE ±4.6 TO DECK • • %%... SEPTIC PIPE (TYPICAL)/ N. 0 3 ` NPC9/ \titl�". • CSS S+rS covc, ±18.1 TO OU • toNc. ' i AoP/ AND LEVEL DECK ;so �\ 1,.4:73- NEW 3—STORY -p : v MULTI—LEVEL FRAME HOUSE W/ GARAGE -a is cP • LOT 10 •o, Ns NOTE& • °'� p '\. • • I. SEE PLAT NOTES F APPUUBLE. 2. NOT ALL CORNERS SWIM VERE RECOVERED CN 1146 DATE, SOME VERE FOUND DURING AN EARLER SURVEY. 3. THS LOT IS SERVED BY CITY WATER. • • GRAVEL \ DRIVEWAY % ; ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT MEMORANDUM OF UNDERSTANDING BETWEEN MUNICIPALITY OF ANCHORAGE AND THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this /31q�s1" 29 Day of 2 6 I . of 20 / 2„ by and between herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as Ad V Q 4 " CX located at r3 re a 2 viJ r 6113 &3, Yck lit r4 or. 2. Definitions. Nt5'. TY deAnchorage, Alaska. A. Alteration. Any change to the design or function of an AWWTS that Includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Prior to performing any alterations to an AWWTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65. B. Certificate of On -Site Systems Approval. An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. The term begins on the date of approval by the Municipality of the installed system and shall continue while the AWWTS system is in use or operational or until the property is sold or title is transferred by owner and a new certificate of On -Site approval is issued to the new owner or transferee of the property. 5. Alterations, Installation and Removal of Additional Equipment. Owner agrees not to make any alterations, removal of parts or additions to the AWWTS without a Construction Permit from the Municipality. 6. Maintenance and Repairs. A. Throughout the term of this Memorandum of Understanding, the Owner shall maintain AWWTS in good repair. In addition, it shall be the responsibility of the Owner during the term of this Memorandum of Understanding, and any extensions or renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. Further, Owner agrees to comply will all applicable ordinance, laws, regulations, rules and orders for the AWWTS. B. Owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's AWWTS Operating Permit. This schedule shall be submitted to the Municipality annually upon the renewal of the permit. The schedule of maintenance and repair contained in the Owner's AWWTS Operating Permit is: C. Owner acknowledges that the fine schedule for failing to maintain and repair an AWWTS are codified in AMC 14.60. Owner: Anchorage: Purchasing Officer C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. 10. Severability. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandum of Understanding. OWNER: MUNICIPALITY• By: C;�/vri,kr.i�..;nt By: J / Title: Date:tU) - ,a t Date: STATE OF ALASKA THIRD JUDICIAL DISTRICT ) ss. The foregoii; instrumeM was acknowledged before 20/5,, by ( (772////:',7,22‘ , the NORYPUBLIC FOR ALA A i M/Commission expires: / `-/ ��tI? me thid s, L ay of / /14,/ F'(( 0 . ottlittio .‘‘qiiiikitt Clef JJJ.)\\\\,; CIO/ LL/ LU1L 1q: 31 bbbbf lG HrLun 209 640 s 11■ i i■ ■ r iii i■ ■■ 1 i 11111 w nu MS III i ■■ ■ii■ ■ ■ i III 1 ■ ii uta ■I i lei MR 1 ■ ilii ■ M ■ MINN ■ ■ we rMUC u Wiverfirboxe Meld Maintenance Report AnchorageTank & Welding, Ind Annual Inspection 907-272-3543 Properly Ownerrrrecpne v Carmen Devore °remser Mike Blakeslee sitsAdams 11643 Birch Hills Drive, Eagle River AK 99577 ConIM Prime (907) 896-7173 AX Sin ip e AX -109126 Retrieve O&M Info D eity ?our Recirc ratio Tuner settings Comely au/ SW080031 Pod* 207710 RTU108767 Ode or Leet lnrpreaon 05127/2011 FiratsV 174 F&st ifrome, 6f "-L . Perrone" Field Sampling/Ohservetions IOU 16 0DIf pH(s-u) 6, 0012-0 5 Odor of Sample Typical WMvsry 'leanly ❑Moldy Ilan-typlmd 0Sulfide I.7 Cabbage El Decay O ily lam In PVC ❑ ver. WNo Foam In tank L, I Yes kmo Cheek Control Panel R s Di NAM Amps HIT° Audible and Visual alarms Innc� gas Mat tone (telemetry only? L Yos 0 NO inspect/Clean Pump .System 1 Int Clean Riaredud Spline Box Float Coeds Floats Pump B lptubbe niter Bbtube Pump Vault Reelmulsann Spider Valva Commerda Measure Studge/Seum 5tudae tat Comparlmenl Cunenl// ca Previous Current Prevbne 2nd Compartment CUM // PTVleue Conant Pnvioue Inspect/Clean Mennen Filter Odor x�.rNomrel 0 Pungent Monttepi�Normd ❑ Excessive BrkdgIng/Pandmg:kOnWerhlsr ❑Excessive Inepect/Clean Dlscherge Pump System Inspect Remelld apace Box Float crude ❑ 1 Inspect Crean 1-ntemlanarlfices rodd Bottom Intake Vent FICAta Pump Inspect Clean ❑ 0 ❑ Cl Inspect/Service Other System Components Impact Clear" Inspect DishdeceOn Equipment l❑ ❑ Dlsparea! Laicals/Orifices ❑ Clean O Obaervellmf9 Additions) Services Rendered ❑ Cleared textile sheets? ❑ ReptecedNSd other koros? Parte Used: We Warranty, a m Billable (1 appaapdats sehctlen) w s item Number Baaenptton ❑Replaced the Items? Final/ - -: Inspection v reinetaaed Itnld reconnected; Hush valves closed ,rb'� at Pk:G i ch b ri y L,µ"^�,.,eids bolted on tercet panel rt+acavated Summery/Recommendations eery/Recommendations J System performing; no tinter wenn needed ID Toth recce pumping ❑ Call ter 5orwloc ❑ other? Oats Fax completed form to 1-866-384-7404 Municipality of Anchorage No P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (9071343-7904 • Fax (9071343-7997 http:llwww.muni.orq/Onsite Development Services Division On -Site Water and Wastewater Program epartinen t **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP121265 COSA#: OSC121378 Permit#: PID#: 050-131-32 Legal Description: Broadwater Heights, Tract D. Block 1. Lot 19 Engineer: North Rim Engineering Applicant: Wayne DeVore Your request for a waiver of the required 100 feet horizontal separation from the absorption field and septic tank to the surface water has been approved. The approved separation distance is 60.0 feet. This waiver approval applies to the existing absorption field and septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ® Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. ❑ Adjacent properties are not affected by this waiver. Waiver is Granted: Date: 134,42 X Waiver is not Granted: Approved by: Name of Reviewer Rec#: 04543C Amount: $800.00 Date Paid: 8/23/2012 **** VARIANCE/WAIVER REVIEW **** TFRIM ENGINEERING Date: 8/22/12 To: MOA On -Site Services Subject: Broadwater Heights, Tract D, Block 1, Lot 19 WAIVER REQUEST MEMO Steve Eng, PE, PH (907) 694-7028 tel NorthRimEng@aol.com Number of Pages: 2 The subject property had a new wastewater system constructed 6 years ago. This was an advanced wastewater system. The system was previously approved by the MOA and a COSA issued. The property is being sold and now requires a new COSA from the MOA. During the COSA inspection it was discovered that surface water is present at a horizontal distance of 60' from the "Advantex" wastewater tank and drain field. After consultation with the owner and MOA, we will request a waiver according to the State of Alaska (SOA) Memorandum on waivers. We expect that the general score for the waiver will not be a high number, but the SOA Memorandum allows for mitigating factors which may allow a waiver. In this case the mitigating factor is the advanced wastewater effluent from the "Advantex" wastewater system. Geological: The MOA approved the wastewater system at 4' to groundwater and 5' to bedrock from the bottom of the leach field. This was done due to the mitigating factor of the advanced wastewater system. We are also making the same argument for the horizontal separation. 1. Water Table: The distance from the bottom of the system to the highest water table is 4'. This only gives a point total of 0.5. 2. Soil Sorbtion: The soil tests from the MOA file indicate the soil is GM, silty gravel. The average of gravel and silt equals a point total of 1.75. 3. Permeability: There is not a point value for silty gravel, so a combination of silt and sandy gravel will be used. This yields a point total of 1.5. TERIM ENGINEERING MEMO 4. Water Table Gradient: The water table gradient is at -5%. The ground slopes toward the surface water. This yields a value of 2.0. 5. Horizontal Separation: The horizontal separation is 60'. This yields a value of 1.4. The total point total = 0.5 + 1.75 + 1.5 + 2.0 + 1.4 = 7.15 This is not a point total that would normally allow the waiver. However the SOA Memorandum places special emphasis on "mitigating" factors. The essentially clean effluent from the "Advantex" advanced wastewater system will not pollute the surface water. Anchorage Tank continually monitors the system from their office via telemetry. We request the surface water waiver due to the advanced wastewater system, as was previously approved by the MOA for groundwater/bedrock separation. If there is need for additional information or clarification please give me a call. Thanks -Steve c..s . • •es. e 0t .N i i ., a% *� 4C]Y}g4G s °an * et 4' 5•....ei.. yv1 . fJ'i ir �P`�, .i. Steven W. Eng 441:-],•.0 PE2 Z Waiver Request: Advantex Tank & Drainfield @ 60' From Surface Water urface Water Small Stream ••��pF "�r4 >cF . t NORTHR/M i*�4sm : a�. ENG/NEER/NG 1 PO Box 770724 b, 1 Eagle River, Alaska 99577 9 4� 907.694.7028 BROADWATER HEIGHTS TRACT D LOT 19 SURFACE WATER WAIVER REQUEST 1" = 40' PLAN LAYOUT Data: EETt 8/27/12 1 C �J teat/co'- AI 8/cam, / APPLICANT'S SIGNATURE: i n4 t -c - ds CJS a Lt 253 h'rOZ1/4 DATE: d9t70/2' Subscribed and sworn to before me this day of Oki.* �< r :' e1OTA �UBLIC in and for the`STATE OAS Paitie ea an L.T Ommission expires: P- �J ?Q/7