Loading...
HomeMy WebLinkAboutBUBBLING BROOK LT 2ubbling rook Lot 2 015-492 -14 MUNICIPALITY OF ANCHORAGE �t�,cnr On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road �. Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite Q t; f DelrtrUnent On -Site Wastewater Disposal System Permit Permit Number: OSP231343 Effective Date: 10/6/2023 Work Type: SepticTank Upgrade Expiration Date: 10/5/2024 Tax Code Number: 01549214000 Site Legal Address: BUBBLING BROOK LT 2 G:2638 Site Mailing Address: 6251 BUNNYSHOE CIR, Anchorage Owner: BIGALKE ANDREW & YVONNE Lot Size in Sq Ft: 46250 Design Engineer: FORGE ENGINEERING Total Bedrooms: 4 This permit is for the construction of: Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing -#-I " p , T tc L-0 t I/ 6/'20--_'� Received By: s�i F_Lr) t� G Date: Issued By: Date: - Community Development Department:,_ Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-492-14 Property owner(s) Andrew Bigalke Mailing address 6251 Bunnyshoe Drive, Anchorage, AK 99516 Day phone Site address 6251 Bunnyshoe Drive, Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Bubbling Brook, Lot 2 Legal description (Township, Range & Section) Lot Size 46,250 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial n Single Family (SF) ❑x Septic Tank ❑x Upgrade p (w/wo ADU) .Holding Tank ❑ RenewalDuplex ❑ (D) El Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. I U (Signature of property owner or authorized agent) Permit/Rush FeesA 225 Date of Payment: laZ � -2 Receipt Number: 0502.273 Permit No. 05 P Z3 I 3-7, 9 3 Permit App_'- : - Waiver Fees: Date of Payment: Receipt Number: Waiver No. r �J` Gi4j• r,;�' September 19, 2023 PO BOX 240773 C_ ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) FORGECIVIL.COM MOA Development Services, On -Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Bubbling Brook Lot 2 - Bunnyshoe Circle Septic System Replacement Dear On -Site Services Engineer: The owner of the above lot has a septic tank that has reached its end of useful life along with a failed trench, so we are submitting this permit application for a new system. The attached site plan identifies the location of the home as well as the wells and septic location. No conflicts exist between this proposed system and any other wells or septic system, whether on this lot or adjacent lots. The lot is primarily flat, with minor slopes in varying directions. The new trench will be placed where there is a gentle slope down from the neighboring property, and will be placed parallel to the contours. There are no steep slopes within 50' of this new trench. Storinwater will not affect the system. It will be placed 16' away from the existing trench, which will be decommissioned. The septic tank will be replaced with a 1500-gallon steel STEP tank in the same location as the old tank. Wells on this and adjacent lots are shown, and there are no conflicts, whether on this lot or adjacent lots. The tank and trench are 100' away from surface water. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjami Schiller, PE BUBBLING BROOK, LOT 2 / i i / / / / / r j WIRE FENCE I ®, 1\ LOT LOT 7 \ 'CREEK \ MAINTE NCE EASEM61T� �i L0f \2 - I \ r r / / CgNFIRM LOCATION �F NEIGHBORING WELL AND 10 ' / SE�ARATtION DISTANC / r 1-1 \\ / / 4-BDRM HOME / L'06ATE EX STING CLEANOUT, / REPAIR IF NEI<D, AND INSTALL / A NEW DR\(EABLE—COVER SMOKER 10' UTILITY EASEMENT *' 48 TH ...:* .� . Benja i Schiller ��% c%1T� • C11013o 233 , • •�() i\�� PROFE SSIONP�' m FRENCH TO IN SERVICE BUNNYSHOE COURT SEPTIC PLAN 0 50 100 FEET 1 "=50' co �I- LOT 6 DECOMMISSION EXISTING 1250 GAL SEPTIC TANK PER UPC i NEW 1500 GAL \ STEP TANK PROVIDE VALVE \ AND PIPING TO \ BOTH TRENCHES NEW 65' LONG x 8' DEEP ABSORPTION/ TRENCH - MAINTAIN 16' SEPARATION FROM EXISTING TRENCH DECOMMISSION LOT 3 EXISTING TRENCH LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEAN( FS - FLOW SPLITTER VALVE MH- MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE BUBBLING BROOK, LOT 2 C-0 a.2 DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW 8' DEEP TRENCH SYSTEM PERK RATE: 6.0 MIN/IN 1500-GAL STEP TANK APPLICATION RATE: 0.6 GPD/SF (CONSERVATIVE) 600 GPD / 0.6 GPD/SF / 8 DEEP / 2 SIDES = 62.5 LF TRENCH REQUIRED (65 LF SPECIFIED) BOTTOM OF TRENCH: 9' BELOW GRADE FLOW LINE ELEVATION: 1' BELOW GRADE "�" "r��'TI �"'"' FILL TO ENSURE R AFTER SETTLEMENT RIC 7 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY F a GE ^�, J_ E N G I NE E R I NG l s 1 1 '497H *� . . ..�. • . .. Benja'n Schiller II�6, CE 12592 s 10130123 �li\e�PROFESSIONP�� � DEPTH (feet) 1- 2- 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 GE SOILS LOG AND PERCOLATION TEST ENGINEER 1 N G LEGAL DESCRIPTION: BUBBLING BROOK, LOT 2 PERFORMED FOR: ANDREW BIGALKE DATE: 10/13/2023 PARCEL ID#: 015-492-14 TEST HOLE 1 1' OB • L•. ' GM (SILTY SAND WITH SOME COBBLES) 17_ NO WAS WATER ENCOUNTERED? - IF YES « WHAT DEPTH? 13' DEPTH TO WATER AFTER MONITORING 10/20/23 DATE OF MONITORING DATE READING START TIME NET TIME (MINUTES) DEPTH TO WATER NET DROP INCHES) (INCHES) --- 1 10:30 21:19 5" 1111 6" 2 33:09 5" 1111 611 3 35:49 5" 11" 6" PERCOLATION RATE: 6.0 (MIN/INCH) COMMENTS: USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED SITE PLAN TECHNICIAN: B SCHILLER Lot 7 j 1 i _ s / 66 4, 08 F 21 Lot 6 Lot 2 FyS, FN AFF \ \ \F�q�c / / U 46,250 S.F. CHAIN—LINK ` \ L�FENCE \ 4 \ WELL k 4.0x24.4' \ DECK CANT f Lot 1 32.4'* r 48.4' 2 STORY Cry � 14. a' RESIDENCE N a o N V \ WIRE FENCE --,,,.,,Z DECK o I 3-�NEIGHB0R'S SHED 2.0'x4.8' 24.2' Q \ CANT / O Lot 3 6.7. V k / -:1I SEPTIC N / PIPES 3'x3' SMOKER n x1 } \ / CHAIN-LINK FENCE SEPTIC PIPES J 9a;90RSD 10' UTILITY EASEMENT / 1 ro L O I U I r. BUNNYSHOE COURT PLOT PLAN AS BUILT _X_ SCALE _1" =50=_ GRID _ SW 2638Project No. 2_3-4481A1 __ 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Assoc ! a t e s , inc. (907) 522-6476 Phone ken®Iangsurvey.com Professional Land Surveyors jonatha n®longsurvey.com OF At kk travis®Iangsurvey.com �� AWP' •. ••� I hereby certify that I have surveyed the following described property: ��.' LOT 2, BUBBLING BROOK SUBDIVISION (PLAT No. 78-110) 10 49TH ••*��J Anchorage Recording District, Alaska, and that the improvements situated thereon are � • • • • • • • • I within the property lines and do not encroach onto the property adjacent thereto, that F • • 0 no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible �� • • ' y ' KENNETH G. LANG easements an said property except as indicated hereon. kt•5t>[�sc l�na%u6l �jJ'fF� •' •Y�Uij•' •S�l�_� Dated this the Day of _ _ at Anchorage, Alaska ``�;; It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. State of Alaska AECC963 Municipality of Anchorage ."¥ Development Services Department Building Safety DMsion On-Site Water and Wastewater Program. 4700 S. Bragaw ~L P.O. Box 196650 An~omge. AK 9951~650 Page of ~.d. ancho~e.ak.us (90D 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM ANDIOR WELL INSPECTION REPORT Permit Number: S~O~O~ PIDNumbe~ 015- ~- "~: ~ ~A~, ~ ~,~ ~0,~ Wastewater System: DNew ~Upgrade A~ress: [~1 ~o~s~o~ ~ ABSORPTION FIELD q LEGAL DESCRIPTION O, ~ ~,~.f Bl~ Lot: S~ ~ ~ ~ ~ ~ ~ ~e: ~ ~ ~a~ ~: Well: ~ New D Upgrade. ~ ~ n. · ,.,.. ~ ..w s,~.~ I c,,~..~ ~ TANK SEPARATION DISTANCES ~s~ptic ~ Holding D S.TZ.P. D Othe~ ~o Septic Abso~tio~ LI~ Holaing Publl~l~ M~ Tank Field Station Tank S~r Une ~ ~ ~ ~ / X ~*~"~': BENCH )~d ~L Development Se~ices Depaflment Approval ~ ~% Reviewed and approved by: ~ Date: ~ I1 FT Lk'Z'P I I 10' / SWING11ES: AC 41.4 ri' · c 18 AD 40.5 afl 19.5 A,g 52.5 ~O 44.$ !1I / / N 49th TOB% ~PURKLAN~ No. C£-E225 L~ O Z'5 .~0 75 100 SCALD 1' = 58 IL~5 150 · L'N~H W,4RK: A,~IJWL'D L'ZLrV. IO0.O0 fT TOBBEN SPURKL4ND P.E. 203 VI 15Tit. AVENUE ANCH. AK. 99501 (907) 279-3916 LOT £ B~IBBLING BROOK $/D J. DAVID SV/ANSON 6251 BUNN¥SNOE CIRCLE SEPTIC SYSTEW AS BUILT DATE: SEPT. 30, 2003 SHEEr: 2/3 GRID: 2638 PERMIT #Sh~030362 PID # 015-49£-I4 BBBOOO£~.DV6 to 1250 ga! Septic ~ank 10 ~4~ Standard Trench: 2' 65' Lon~ I1' Beep 8,0' Sewer rock $' Cover NO SCALE Monltor Cleanouts 3' Cover B,O F't oF Septic Rock Effective NO SCALE AS BUILT 1250 GAL SEPTIC TANK !0 ~4Gg 803 ~/15'th Ave Anchorage Ak 99501 P79-2916 PERt, Ill' I~ SWOJO$$2 LOT 2 BUBBLING BROOKS S25I BUNNYSHOECIRCLE SEPTIC SYSTEM SCHEMATIC DATE, SEPT. $0, PARCEL I0 / 015-492-I4 BBBOOO25.OWG MUNICIPALITY OF ANCHORA GE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Sap 08, 2003 Expiration Date: Sap 07, 2004 Permit Number: SW030362 Legal Description: BUBBLING BROOK LT 2 Design Engineer: 0007 Tobben Spurkland, PE Owner Name: J. David Swanson Owner Address: 6251 BUNNY SHOE CIR ANCHORAGE, AK 99516-2411 Parcel ID: 015-492-14 Site Address: 006251 BUNNY SHOE CT Lot Size: 46250 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AACBO ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: Date: · Municipality of,Anchorage .' . DeveloPment ServiceS Department Building Safety Division On*Site Water and Wastewater Program 4700 South Bragaw St. P,O, Box 196650 Anchorage, AK 99519-6650 www,ci.anchorage:ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Permit Number SW 0 .~0 Y~;~. Property owner(s) Mailing address (1) Mailing address (2) Legal description (Lot, Block & Sub'd,) , [")Avt~ g, tY.//~r/xJSC)N Dayphone ,\ Zip Code ~J Legal description (Section, Township & Range) Lot Size ~ [o ~ ~ ~ AcresG . Number of Bedrooms THIS APPLICATION IS FOR:' Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Well Only. [] Water Storage [] Jacuzzi Water Softening Unit I certify that the above Information is COrrect. I further cedify that this application Is being made for a Single Family Dwelling and is in acCOrdance with applicable MunicilJal Codes. (Signature of property owner o.~' authorized agent) · , ~t I Permit Fees: ~ /7'/~:~~ ~ ' ' WaiVer Feesi ' Receipt Number: q OS ~ .L~ (Rev. 12/00) Date of Payment: Receipt Number: 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 2 BUBBLING BROOK S/D J. DAVID SWANSON Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bmgaw Street Anchorage, Alaska 99519-6650 August 20, 2003 We are submitting an application for the upgrade of the septic system for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet I/3), the proposed improvements of the lot, of which only the septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: No Ground Water or Impervious Layer to 17 iL Use Standard Trench Soil Rating. From Testhole 07/12/02 17 min/in=0.6 gal per sq.ft/day No. of Bedrooms 4 Required Area per Bedroom: 150/0.6 = 250 sq.iL Total area required: 250 x 4 = 1000 sqR Testhole depth 17 feet Bottom Rock At 11 feet Top Rock At 3 feet Rock Depth 8 feet Minimum Trench Length 1000 / 16 = 62.5 iL Use 65 ft SYSTEM CONFIGURATION STANDARD TRENCtt TOTAL LENGTtt 65 FT TOTAL WIDTH 2 FT TOTAL DEPTH I 1 FT ROCK DEPTH 8 leT COVER 3 FT SEPTIC TANK 1250 GAL 10 GAGE THICK WALL The installation ofthis septic system will not prevent wells and septic systems from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope ofthe area. Ponding and/or concentration of surface runoffwill not result from this installation. I I I I ! p,,,.---"~ '" iii I iiI 5O 0 5O 100 15O PO0 PSO ,9O0 SCALD 1' = loft FT. SEPTIC SYSTEY flESI6'Y DATE: AU~. 20, 2003 SHEET: I/3 CRID: 2838 / ~ ~eH 8 fT I I0 TANI~ FT COV~ VAL V~ .4~ Rrell ~XIST. DIb~N f , N 49-~h SPURKLi~]~ CE-e~.5 SCALE, I' = 50 FT. TOBBEN SPURKLANO P.E. 205 ~7 151H. AVENUE ANCI. I. Al(. 99501 £OT £ BUBBHNG BROOK J. DAVID SWANSON $251 BUNNYSMOE CIRCLE ] SEPTIC SYSTEM DESIGN DATE: AUG. 20, 2.005 SHEET: 2/$ GRID: 2636 PERMIT # SVO30xxx PID # 015-49£-14 BBB000£3.DVG 1250 ga! Septic tank ~0 ~ 0 Standard Trench, Vide ~5' Long Beep E.O' Sewer rock Cover NO SCALE /Monltor Cleanoufs B' Cover B.O £~ of' Septic Rock / Effective 1250 GAL SEPTIC TANK fO CaC£ NO SCALE TDB~EN SPURKLAND P.E. Ii 203 ~15~h Ave Anchorage Ak 99501 LOT 2 BUBBLING BROOKS S/D 625I BUNNYSHOECIRCLE J. DAVID SWiNe. ON SEPTIC SYSTEM SCHEMATIC SHEET, ,,.T,/,,,.T GRID, 2638 ! P£Rt~IT {f SWO$OOXX PARCEL ID ~ 015-4~2-I4 BBBOOO2$.DIC8 Pe.'formed For: Legal Descripticn: o 1. 2- 3- 4- 5. 6- 7- 8- 10- 11- 12- 13- 14- 15. 15- 17 COM:,tE,'-;T$ Municipality of Anchorage Development Services Departmenl Building Safely Division On-Sile Water and Wastewater Prcgram 4700 South Bragaw SL P.O. Box 1.~66,~0 Anchorage. AX 99519-6650 ww, v cl.anch~aqe .a~( .us (9O7) 343-79O4 Soils Log - Percolation Test Township, Range. SecSon: Site Plan st,-1 WAS GROUND WAT£R EXCCU;:TERED? ["~ ~O S IF YES. AT WPAT DEPTH? Depth to Water' A~er Monitoring? I I I I I i Gross Time I Net Time I Dep~,h to WaterI I'tet D'c;:) [ I I::E R~CLATICH RATE J "~ . (,"¢~ue~,'~C~} F=RC ECLE Ct,~.'.t=TE=, TEST Ru~,: B.-'r~/£~H ~ ~ ,~.,~o ~,,. ~ I I PERFORMED BY: - i ,,,- ~ I "~...-.~ CERTIFY THAT THiS TEST PERFOR:,,!ED h',l ACCORDANCE WITH ALL STATE AND MU.',;:CIPAL GUIDELINES IH EFFECT DJ"! Ti~IS DATE. DATE: ~"/~.. //~t"IJ//~'1, ~__~t/-"; "~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME 1PHONE / a'EW MAILING ADDRESS LEGAL DESCRIPTION LOCATION NO. OF BEDROOMS ~ Material No. of compartments I-Z Manufacturer(-~  Liq. capacity in galJons Inside length Width Liquid depth i~0 IF HOMEMADE: 6 v DISTANCE TO: Well Dwelling PERMIT NO. .jt3Z O Z <[ Manufacturer Material Liquid capacity in gallons C~ We/J Foundation Nearest lot line PERMIT NO, -- ''7' Z ~°[~c e.~l cf lines Trench wid~ ~ D is tan c e bet we~l~/~l~S ~ No. of lines Lengt h line Total I I- ~ ~ inches - Total effective al~lsorption area . re~- Top of ti~e~.f~inish grade Material beneath tile Length Width Depth PERMIT NO. uJ <~ I- Type of crib Crib diameter Crib depth Total effective absorpuon area '" Well Building foundation Nearest lot line ;o DISTANCE TO: . Class Depth Driller Distance to lot line PERMIT NO, tu Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: OT~:R SOIL TEST RATING INSTALLER \. REMARKS APPROVED ~ DATE LEGAL 72-013 (Rev, 3/78) UNWIN- SCHEBEN 'KORYN TA su.v ¥o.s 2515 A ST., December 5, 1977 · ANCHORAGE 99503 . (907) 276-4245 Mr. Buster Newton "~ '- 411' East 36th Avenue -~''' Anchorage, Alaska 99503 Re: Proposed Bubbling Brook Subdivision Subsurface Soils Investigation Dear Mr. Newton: This report presents the results of our soils investigation for the proposed subdivision of a l0 acre tract located east of Birch Road and just west of ' Ravenwood Subdivision. The investigation was~conducted on November 15 and 16, 1977. The results of this investigation are included in this report as follows: Vicinity Map Test Hole Location Sketch Test Hole Logs (Sheets 1 through 9) Standard Explanatory Information Drilling was accomplished utilizing a mobile drill B-50 mounted on a flex track Nodwel vehicle, owned and operated by Denali Drilling, Inc. Test holes were logged and perculation tests conducted by our firm. The purpose of the investigation was to provide soils data and perculation tests for establishing the feasibility of on-site disposal of sanitary wastes using seepage pits. To accomplish this, we drilled 9 borings distributed across the site with 1 test hole on each lot at the probable septic system location. The test hole locations are shown on the attached location sketch. All borings were drilled to a depth of 16 feet. During the drilling, our engineer was present to log the materials encountered and obtain grab samples of the sol) types. All soils were visually classified in the field in accord- ance with the unified soil classification system as described in the standard explanatory information attached herewith. Since the site is fairly small and readily accessible from both sides, per- culation tests were conducted in all holes at the completion of the drilling and logging. The perculation tests were conducted from the 6 to 12 foot levels in each of the holes in accordance with the Manual For Septic Tank Practice published by the PHS. A ground water table was encountered in test hole Number 9 at the 12 foot level. Therefore, the perculation test in this hole was conducted between the 4 to 8 foot level. 'NWIN,P.E. LEO SCHEBEN,JR.,P.E.,L.S. EARL O. KORYNTA~ RE. Mr. Buster Newton December 5, 1977 Page Two SITE.AND SOIL CONDITIONS' The site is a~660 foot ~quare parcel having access from Rockridge Drive on the east and Ravenwood Subd.~¥isi~n on the south. The site is dissected in a southeasterly/northwesterly 'direction by a fork of the Little Campbell Creek. The parcel slopes uniformly from southeast to northwest at an approximate 6% to 8% average slope. A small 'knoll is located in the southeasterly corner. There are no areas with slopes in excess of 25%. The parcel may be divided into two very distinct soil map units for purposes of identifying perculation characteristics. A 300~4J~O~.~ot wide band center~d. Qn the creek channel is cha~acte~~c_~_~)..d alluvial..depositS-~nd-c~n~Sts primarily of well g~aded .~anos and gravels with~'~'O~ perculation characteristicS, Test holes 2, 9__arreStor this deop.~9_it. Beyond this band, th~ siltier and tig~e~-'~-~emonstrated by test holes ?, 3, 5, 6 and 7. CONCLUSIONS The minimum perculation rates observed in'the field for the.following holes are: Test Hole Number 1 - 30.minutes per inch TTe.~stHole ~2_.__l~tt~.~,~jl~b est Hole Number 3 - 30 minutes per inch Test Hole Number 5 - 25 minutes per inch Test Hole Number 6 - 45 minutes per ~nch Test Hole Number 7 - 60 minutes per inch Test Hole Number 8 - 5 minutes per inch Test Hole Number 9 - 5 minutes per inch On-site waste disposal systems appear feasible on all lots. An aerated package plant or other treatment process is advisable for the lots with high percula- tion rates. We hope this is sufficient for your present needs. clarification, please do not hesitate.to contact us. Attachments EDK/clr If we can offer further Very truly yours~ Earl D.~ Korynta, P.E. · 5.17 / i / .% RG LEGEND I / / / / / / / / / / 'SURVEYOR'S .CER 3' I FI CATE._~_~ ~ ~ · profes~al '" 752 DRILLING, INC. 79-108A Well Owner. Location DRILLING LOG GUNNARSON CONSTRUCTION Use of Well DOM. (address of: To~vnship, Range, Section, if kno~vn; or distance main road_ Lot 2 Block 1 Bubbling Brook; Subdivision, Anchorage Size of casing Static water level Screen ( 1t ); Depth of Itole 2__0__2_ ....... feet Cased to__29__1 .__2___deer ft. (RtR~IK) (below) land surface. Finish of well (cheek one) Perforated ( ). Describe screen or perforation N/A Well pumping test at_2L0___gallons per of drawdown from static level. Date of completion 1 / 4 / 79 (minute) for ..... _1_ ....hours with WELL LOG Depth in feet frmn ground surface Give details of formations l)enetrated, size of material, color and hardness open end ( ); ..... O__TO Z .... 2 TO 23 4_3~_TO 35 _ ~5__TO 50 .... ~Q__TO 68 .... TO 95 2~5__TO 105 105 _TO 135 _..~J5 .... TO. 14i _i56 _TO_ 165 196 _TO__~)_2_ ..... Ga s in g ~Jz.Lc kup ......... Silty gravel: cobbly Sandy g_~_a ze 1- ..... L_Lgo s_e__g_r_aye ~_ _S i_ 1 tf__c__l_a_y_ _ S__i__l_t.'l hard pan__. Boulders ..... ~and_y hard pan ....... _D_am~p_gr ave 1 Silty. clay .2tar d_ pan Boulders _C!~y .... _Water gr2v al 1 - CUSTOMER MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVl RONMENTAL PROTECTIO~'VIRONMENT'~'L  825 L Street-Anchorage, Alaska 99501 J A N ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720RECEIVED REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete reques~ will not be proces~d. Please allow ten (10) davs for processing. 1. PROPERTY OWNER I PHONE MAILING ADDRESS ~ PROPERT~ RESIDENT (If different from above) PHONE 2. BUYER PHONE 3. LENDING INSTITUTION I PHONE MAILING ADDRESS 5. LEGAL DESCRIPTION S*R[ET LOC^'nO~ J~ SINGLE FAMILY [] MULTIPLE FAMILY NUMBER OF BEDROOMS [] One [] Four [] Two [] Five ~ Three [] Six [] Other 7. WATER SUPPLY INDIVIDUAL~ [] COMMUNITY [] PUBLIC UTI LITY 8. SEWAGE DISPOSAL SYSTEM INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY * ATTACH WELL LOG. ,A wel! Io~] is required for all wells drilled since June 1975. For wells drilled prior ~o that date, gJ, ve well depth (attach log if available.) ~ **If individual/on-site, give installation date,-~- ~ )'~?~. If system is over two (2) years old an adequacy test is required by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010(3/78) THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: NUMBER OF BEDROOMS 1. TYPE OF RESIDENCE ~ SINGLE FAMILY [] MULTIPLE FAMILY 2. WATER SUPPLY [~'"~N DIVI DUAL F-I COMMUNITY [] PUBLIC UTILITY Connection Verified 3. SEWAGE DISPOSAL SYSTEM [~]~IVI DUAL/ON -SITE [~]PUBLIC UTILITY Connection Verified [--]Septic Tank or []Holding Tank Size:~ If Tank is homemade give dimensions: TYPE OF TANK TOTAL ABSORPTION AREA 4. DISTANCES WELL TO: Absorption Area to nearest Lot Line [] ONE [] THREE [] FIVE [] TWO [] FOUR [] SlX PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED PERMIT NUMBER DATE INSTALLED INSTALLER SOl LS RATING MANUFACTURER MATERIAL Septic/Holding Tank Absorption Area 1Sewer Line [] OTHER Nearest Lot Line 5. COMMENTS ~]~PPROV ED FOR ~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED ~L~~ ~/~//~ I BY (Title~,~ DATE LEGAL DESCRIPTION 72-010 (Rev. 3/78) Municipality of Anchorage ° On -Site Water and Wastewater Program (907) 343-7904 5 Certificate of On -Site Systems Approval Parcel I. D.015-492-14 1. GENERAL INFORMATION: Complete legal description Bubbling Brook; Lot 2 Location (site address) 6251 Bunnyshoe Circle *Anchorage, AK Expiration Date: /f - I3 •ZD7 Current Property owner(s) Day phone Mailing address Real Estate Agent Michelle Webb Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 50 Waiver Fee $ Date of Payment g 13 a a 2 t Date of Payment Receipt Number 0 L4 601 G Receipt Number COSA # OSC 2 I I L1 79 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineerinq Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date �b)tt I•Zr In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the G DE A evaluation. Separation distances were measured to readily identifiable features. Hidden defects ori�� • . • • • . . encroachments may exist that were not identified during the evaluation. The operational life of all wells ,� P .- S% i and septic systems depend upon a variety of variables, including but not limited to, soil conditions,;Il �' ✓� : is , , � ; , •, -y- !) groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and""""'" """" ""' """"" ""' are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of �• (/ the well or septic system. GEG makes no representation whether an alternative well or septic system (b. y A. :.:emess, can be installed on the property in the event either of the current systems fail to perform adequately in �0, �. 1, CE- 719- the 9 the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or �;��� qC1 party (including subsequent property purchasers) is not authorized, nor will it confer any legal right �rores�!` whatsoever. ` #AECC884 6. DSD SIGNATURE System #1 Approved for '1 bedrooms System #2 Approved for bedrooms TYf OF(a((,��•�� Disapproved `\SJ��G\e Conditional approval for bedrooms, with the followinc�t�iul Ic?y-srrE O� a� o IAIA ER AND m J l J� ATER z Original Certificate Date:— r 3 ^ zo?_ The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist 7K - Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other „AA Legal Description: BUBBLING BROOK; LOT 2 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 1/4/79 Total depth 202 ft Cased to 201.2 ft ❑ Sanitary seal is functioning correctly Ef Wires are properly protected Casing height (above ground) 12+ in. Date of flow test for COSA 7/27/21 Static water level at beginning of test 158.3 ft Comments Parcel ID: 015-492-14 Structure served by this system "Well production at time of test 5.5+ gpm Water storage tank volume gallons ' WO'disinfected for coliform test? ❑ Yes ❑ No V Coliform bacteria is Negative F,. Nitrate mg/L NrNitrateless than MRL (ND) Arsenic ug/L fq/Arsenic less than MRL (ND) Collected by GEG Date of Sample 7/27/21 DOUBLE CLEANOUTS AFTER TANK ARE HOLDING WATER. POSSIBLY A SLIGHT REVERSE GRADE AFTER TANK B. TANK DATA C. LIFT STATION Age of tank(s) 18 years ❑ Required maintenance co Tank type/material SEPTIGSTEE Age of lift station ¢-a Measured operating fluid level in septic tank *52 Lift station materiail"' OR Standpipes/foundation cleanout per record drawing Date of pumping SI VT -I — D. ABSORPTION FIELD DATA Which system tested (date installed) 9/2003 ❑ ALL standpipes present per record drawing Total measured depth from grade 12 ft (max) r Measured depth to pipe invert from grade 4.2 ft (min) ❑ NIA – pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective 7.6 Comme Adequacy test date 7/28/21 Results ❑✓ Pass For 4 bedrooms Fluid depth prior to test 68 in Water added 800 gal New depth 87 in Elapsed time 185 min ❑ Code -required soil cover over field Final fluid depth 82 in ❑ System presoaked Absorption rate 600+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) date of test) N/A Gallons introduced "2418 gallons If yes, enter date Comments/Deficiencies: PIPE AT END OF 1978 TRENCH NOT LOCATED "DRAINFIELD DRY PRIOR TO THE PRE-SOAK ON 7/27/2021 COSA Checklist yellow sheet NO E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ® Yes Neighboring Tank > 100' ❑✓ Yes Absorption Field on Lot > 100' F/� Yes Neighboring Absorption Fields > 100' 0 Yes Community Sewer Main > 75' F/ Yes From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No **5 + ft Surface Water > 100' ft ft ft ft ft 0 Yes if No ft Property Line > 5' ❑✓ Community Sewer Manhole/Cleanout > 100' if No ft Q✓ Yes if No if No ft Private Sewer/Septic Line > 25' ❑✓ Yes if No if No ft Holding Tank > 100' Z Yes if No * ft Animal Containment > 50' F✓ Yes if No if No ft if No ft If septic tank is under driveway comment below Manure/Animal Excreta Storage > 100' if No ft ❑✓ Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No **5 + ft Surface Water > 100' ft ft ft ft ft 0 Yes if No ft Property Line > 5' ❑✓ Yes if No ft Wells on Adjacent Lots: Absorption Field > 5'✓� 0 Yes if No ft Private Wells > 100'✓Q Yes if No. Water Main > 10' F71 Yes if No ft Community Wells > 200' 0 Yes if No Water Service Line > 10' ✓l Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Fv Yes if No ft If absorption field is under driveway comment below Property Line > 10' F/� Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' ® Yes if No Water Service Line > 10' 1771 Yes if No ft Community Wells > 200' Yes if No Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS 'PER CONVERSATIONS WITH THE OWNER OF BUBBLING BROOK, LOT 1 DURING GEG SITE VISIT ON 7/28/21, THE SEPTIC PIPES FOR THE DRAINFIELD ARE NOT PRESENT AND COULD THEREFORE NOT BE LOCATED. THE EXACT SEPERATION DISTANCE IS UNKNOWN BUT ASSUMED TO BE 100'+ **MET CODE AT TIME OF INSTALLATION G. ENGINEER'S CERTIFICATION 1 certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with y QO O MDA COSH guidelines in effect on this date. \ � . .. . . .. . . . . . .. . .. • • . _ _ .. • J�f r y rness., ..0 Q 9. CE i7j9r 3 �p e COSA Checklist yellow sheet �o\ o0 ofessW 0 I1 ft ft ft #AECC884 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-492-14 GENERAL INFORMATION Complete legal description Location (site address) Lot 2, Bubbling Brook Subdivision 6251 Bunnyshoe Circle Anchorage, AK 99516 Expiration Date: Current Property owner(s) Edwin and Jennifer Simeonoff Mailing address 6251 Bunnyshoe Circle Anchorage, AK 99516 Day phone Lending agency Mailing address Day phone Real Estate Agent Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: Four (4) Day phone TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class ~ Well Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding Tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. DSD SIG,.NATURE Disapproved. Conditional approval for bedrooms. Phone 522-7773 Date 7/22/2010 bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory (Rev. 11/05) X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: 7~ ~ '~''' / ''~' Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Lot 2, Bubbling Brook Subdivision Parcel iD: 015-492-14 A. WELL DATA Well type Pdvate IfA, B, or C provide PWSID # Well Log (Y/N) Y Date completed 1/4/79 Sanitary seal (Y/N)... Y Wires properly protected (Y/N) Y Total depth 202 ft: Cased to 201.2 fl:. Casing height (above ground) >18 in. FROM WELL LOG AT INSPECTION Date of test 1/4/79 7/15/10 Static water level Unknown ft. 145.2 ft. Well production 30 g.p.m. 7.0 g.p.m. ~ WATER SAMPLE RESULTS: Coliform 0 colonies/100mL Nitrate N/D mg/L ArSenic: N/D ug/I 'Date of sample: .71110 B. SEPTIC/HOLDING TANK DATA Other bacteria Collected by: M. Anderson Tank Type/Material Septic/Steel Date installed 9/8/03 Tank size 1,250 gal. Foundation cleanout (Y/N) Y Date of pumping 7/20/10 Number of Compartments Two Depression over tank (Y/N) N Pumper A Plus Home Services Cleanouts (Y/N) High water alarm (Y/N) C. ABSORPTION FIELD DATA Date installed 9/8-11/03 Soil rating (g.p.d./ft2 or ft2/bdrm).6 GPD/SF Length 65 ft. Width 2 ft. Total depth 12 ft. Eft. absorption area ..1..,040 ft2 Monitoring tube Date of adequacy test 7/15/10 Results (Pass/Fail) Pass Fluid depth in absorption field before test 83.5 in. Elapsed Time: 1,285 min. Final fluid depth 84 Any rejuvenation treatment (past 12 mo.) (YIN & type) ' 0 colonies/100 mL System type Deep Trench Gravel below pipe ... 8 ft. Y Depression over field N For 4 bedrooms Water added 620 gal. New depth 93.2 in. in. Absorption rate >= $0o g.p.d. N If yes, give date D. LIFT STATION Date installed "Pump on" level at~ in. Size in gallons "Pump off" level at~ in. Manhole/Access (Y/N) High water alarm level at in. Datum Cycles tested E. SEPARATION DISTANCES Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >1oo' Absorption field on lot ·1oo' Public sewer main N/A On adjacent lots >100' On adjacent lots >loo' Public sewer manhole/cleanout N/A Sewer/septic service line >25' Holding tank N/A Animal containment areas >50' Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: · 100' Building foundation >5' Property line >5' Absorption field >5' Water main N/A Water service line >10' Surface water >100' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >1o' Building foundation >1o' Water main >1o' Water Service line >1o' Curtain drain None Noted Surface water >100' Wells on adjacent lots >100' Driveway, parking/vehicle storage ·25' F. COMMENTS: Diverter Valve Turned Directing Flow to Old System. Valve Should be Turned Back to New System Once it Ddes Out. G. ENGINEER'S CERTIFICATION I certify that ! have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 7/22/2010 COSA Fee $.,, Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number ~ASEMENTS OF RE C~ORD. OTHER THAN THOSE SHOWN ON TJ',~E RtSCORDED PLAT ARE NOT SHOWN HE~EON, AS-BUILT NO CORNERS SET THiS DATE I hereby certify that I. have performed ~ Mo'[lagee's kn~ speed, on ~ ~e foHow~ng d.escr~bed propertyt ............................................................... men~ situated thereon are within the property ~nes and do not overlap or en~oa~h on the proD~ty lying adjacen~ there~ t~ that no }mprovemen~ on property ly'in~ adjacent there~ encroach on the pre~ses in question ~nd ~a~. thee are no roadway. /r~s~ission lines or o~he~ 'tds~b]e easements on sai. d prOpe~ty except as indica~d hereon. FRED WALATKA & ASSOCIATES Engineers :md Surveyors ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) July 21, 2010 Ed Simeonoff 6251 Bunnyshoe Circle Anchorage, AK 99516 Subject: Lot 2, Bubbling Brook Subdivision Well and Septic System Inspection, Testing and Certification Dear Ed: A flow test was performed on the well and water system on Lot 2, Bubbling Brook Subdivision on July 15, 2010. The static water level in the well was found to be 145.2' below the top of the casing prior to beginning of the test. The water was then allowed to flow freely for a period of 4 hours and the well production measured on a regular basis during that period. The average flow monitored during the test period was slightly more than 7.0 gallons per minute and the static water level dropped slightly and recovered rapidly once the test ended. The well and water system is in compliance with Municipal and State of Alaska Department of Environmental Conservation (ADEC) regulations and meets all requirements for a three bedroom home. We did note, however, a gap between the electrical conduit leading to the well head cover. The current code requires all wiring be encased in conduit from the well head to a minimum of 6" below ground. A water sample was taken from the system and tested for coliform, bacteria, arsenic and nitrate content. The results from the testing are attached and indicate the nitrate content is below the maximum allowable limit. No coliform, bacteria or arsenic was found in the water sample. The septic system was inspected to verify it was functioning in accordance with the original design. MuniciPal records indicate the system was constructed in 2003 and replaced a system constructed in 1978. The newer system is composed of a 1,250 gallon septic tank and a 65' long x 2' wide x 8' effective depth absorption trench. The original absorption trench is composed of a 51' long x 3' wide x 6' absorption trench and is connected to the new system with a flow diverter valve. No monitor tube was found in the old trench, but our probing indicating it is probably dry. The absorption trench constructed in 2003 and currently in service was found to have a total of 83.5" of water indicating only 12.5" of freeboard remaining. We then injected 620 gallons of water into the absorption trench. The water level rose to 93.2". The water level then receded back to its original depth over the next 24 hours. The system is therefore capable of absorbing a minimum of 150 gallons of water per bedroom over a 24 hour period and meets Municipal criteria for certification. Lot 2, Bubbling Brook July 21, 2010 Page 2 of 2 The septic tank was recently pumped and the diverter valve turned to allow flow into the old trench. We recommend using the old trench for at least the next year to allow the new trench to rest and dry out. The valve should then be turned back to allow flow into the newer trench. No monitor tube is in place in the old trench so it will not be possible to monitor the water level in this trench. Sincerely, Michael E. Anderson, P.E. Attachments