On -Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP181052 PID Number: 017-092-30
Dwelling: ❑N Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑■ Upgrade
Name:
Stanley M. Masneri
ABSORPTION FIELD
❑t Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address
PO Box 110230 Anchorage AK 99511
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
3
0.8 GPD/SF
10.7 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
4.7 Ft.
Gravel depth beneath pipe
6.0 Ft.
Subdivision Block Lot
Bunny Slopes 1
Fill added above original grade
0.1 Ft.
Gravel length
48 Ft.
Township Range Section
Gravel width
1.5 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
576 Ft2
1
Ft.
Well
NA
>100'
NA
NA
>25'
TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Existing
Capacity
Gal.
Surface Water
NA
>100'
NA
NA
Material
Number of compartments
Lot Line
NA
>10'ENA
NA
NA
Foundation
NA
>10
NA
LIFT STATION
Manufacturer
Capacity
Gal.
Curtain Drain
None
Noted
RemarksExisting septic tank inspected and
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
verified suitable for continued use.
Pump make and model
Electrical Inspections performed by
PIPE MATERIAL House to tank Tank to D3034
drainfield
Installer
Michael N. Anderson
Drainfield D3034 CO/MT 3034
Inspector J. Millette
BENCHMARK (Assumed elevation) 100 ft
Inspectiones: 15` 5/26/18 5/26/18
Location and description
2nd
Bottom of siding SE corner of house.
3rd 4`h
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
OiFA,gl1l
Conditional Approval: Date
Q. S
1t: 49 TH
TH •.>k
/ .. .........
t✓r • '•
Michael E. Anderson
�+ �F`••
Approved �Q, ��, Date (0 11 1
4381-E•�` AW
AW
iIkI, OPROFESSIO -.
Inspection Repo rt_9-1-12.doc
BUNNY SLOPES, LOT 1
PERMIT # OSP181052 PID # 017-092-30
----J----------------------------
I
� \ I
—� E:- 24th Avenue
'Asphalt
\� \XISTING WELL
441 C
C)
•EXISTING 1250 GAL1CONCRETE
r-1
0
W
0-
O
J
W
W
0
Z
2CO1 --- 4.5 59.3
TANK INSPECTED AND VERIFIED O
=ti< ''
18.0 ---
2CO2
36.3
SUITABLE FOR CONTINUED USE q Mw
°�k
W
33.7 ---
MT
57.8
'
0O2
62.9
1 77.8 - -
Lot 2
\ I B 2co�
i
'^
'U)
i
1.`
v i
48' LONG x 1.5' WIDE x 6',EFF. `' — -, • : ; -- --'� FD
DEPTH ABSORPTION TRENCH-2CO2
-
EXISTING
I
—
/ CO2 C01
TRENCH
W
I
TH
LOT
EXISTING CRIB
1
(EXACT
I
Iw
// A B C
LOCATION'
UNKNOWN)
a-
I O
2CO1 --- 4.5 59.3
DV
44.9
18.0 ---
2CO2
36.3
23.2 ---
001
36.2
33.7 ---
MT
57.8
71.9 ---
0O2
62.9
1 77.8 - -
I I w
i
1
- -- - -- - - - -; ---1---; --------------------
10' Utility Easement!
UNDEVELOPED
*k.NG' Lot 5�
- -M _ar-r-e —'
,"o� OF NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE LEGEND A\\ PROPOSED SEPTIC SYSTEM
CO -CLEANOUT
r.�P• /r i) 2CO - DOUBLE CLEANOUT
CD7 ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
Ar 49 Tli �r�� FCO - FOUNDATION CLEANOUT
. .. .. PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
•��— SYSTEMS. FD - FLOW DIVERTER VALVE
• :. • • MH -MANHOLE
Michael E. Anderson : / 0 50 100
0 SLOPES > 25% MT -MONITORING TUBE
G43 81! -E FEET SLOPES > 46% SV - SEPTIC VENT
�i1;F0PROfEssloNp�+ 1 "=50' TH - TEST HOLE
BUNNY SLOPES LOT 1
PERMIT # OSP181052
93.3
98.1 FINISH GRADE
98.0 ORIGINAL GRADE
DRAINFIELD ROCK
87.3
48'
79.5
'�-i \- NO GROUNDWATER 10/15/95
NOTE:
PID # 017-092-30
ABSORPTION TRENCH ONLY PLACED UNDER THIS PERMIT. EXISTING SEPTIC
TANK INSPECTED AND VERIFIED SUITABLE FOR CONTINUED USE.
��. FORGE
PROFILE AS -BUILT
(NO SCALE)
O
U
93.3
M0
E. 124nd Avenue
N89056'36"W 252.47
7226A
0
co
30 1
LOT J
McCarrey Subd,
_ OF XXI1
A� 1
AM
i • 49th •� ,�j
• /
00
.. r .. ,:
10 �,•. zabeth Walatka . o00
�� sr • • 8036 - LS . • • e
SCALE: 1 "= 50' % X % %:*1 '
EASEMENTS OF RECORD, OTHER THAN 1.-7.9 `
THOSE SHOWN ON THE RECORDED
PLAT ARE NOT SHOWN HEREON
UNLESS OTHERWISE NOTED. FB 75-9, pg 56 BE
N
0
0
0
0
G
Recertified 4-03-11AZUE 08-11gfLc
AS -BUILT NO CORNERS SET THIS DATE
I hereby certify that I have performed a Mortgagee's inspection
of the following described property: LOT 1,
BUNNY SLOPES SUBDIVISION
Anchorage Recording Precinct, Alaska, and that the
improvements situated thereon are within the property lines
and do not overlap or encroach on the property lying
adjacent thereto, that no improvements on the property lying
adjacent thereto encroach on the premises in question and
that there are no roadways, transmission lines or other
visible easements on said property except as indicated
hereon.
Dated at Anchorage, Alaska
this 30th day of December, 1975.
FRED WALATKA & ASSOCIATES
Engineers and Surveyors
907-248-1666
,�
40
wap
2(9SRik
cCD
o
UJ
Lot
2 0
CD
nT
2-6,I
1 2. a
LOT J
McCarrey Subd,
_ OF XXI1
A� 1
AM
i • 49th •� ,�j
• /
00
.. r .. ,:
10 �,•. zabeth Walatka . o00
�� sr • • 8036 - LS . • • e
SCALE: 1 "= 50' % X % %:*1 '
EASEMENTS OF RECORD, OTHER THAN 1.-7.9 `
THOSE SHOWN ON THE RECORDED
PLAT ARE NOT SHOWN HEREON
UNLESS OTHERWISE NOTED. FB 75-9, pg 56 BE
N
0
0
0
0
G
Recertified 4-03-11AZUE 08-11gfLc
AS -BUILT NO CORNERS SET THIS DATE
I hereby certify that I have performed a Mortgagee's inspection
of the following described property: LOT 1,
BUNNY SLOPES SUBDIVISION
Anchorage Recording Precinct, Alaska, and that the
improvements situated thereon are within the property lines
and do not overlap or encroach on the property lying
adjacent thereto, that no improvements on the property lying
adjacent thereto encroach on the premises in question and
that there are no roadways, transmission lines or other
visible easements on said property except as indicated
hereon.
Dated at Anchorage, Alaska
this 30th day of December, 1975.
FRED WALATKA & ASSOCIATES
Engineers and Surveyors
907-248-1666
,N,c'._L�ryo, MUNICIPALITY OF ANCHORAGE �,�,enr
�� On-Site Water&Wastewater Program c° S�
-'b.e' PO Box 196650 4700 Elmore Road
' Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax (907)343-7997
: ;` http:Nwww.muni.org/onsite `
\ \ Department
4';'CHORP6b
On-Site Wastewater Disposal System Permit
Permit Number: OSP181052 Effective Date: 4/25/2018
Work Type: Septic Upgrade Expiration Date: 4/25/2019
Tax Code Number: 01709230000
Site Legal Address: BUNNY SLOPES LT 1 G:3038
Site Mailing Address: 6100 E 142ND AVE, Anchorage
Owner: FORGE ENG Lot Size in Sq Ft: 76500
Design Engineer: FORGE ENGINEERING Total Bedrooms: 3
This permit is for the construction of:
El Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907)343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: 1 /C/!ol---A / {d7 --/ Date: 4/2-5/&
Issued By: Ulrl� -- Date: Y2C//
MUNICIPALITY OF ANCHORAGE
r•
�/
Community Development Department Phone: 907-343-7904� Fax: 907-343-7997
Development Services Division
On-Site Water & Wastewater Program en@�pc C t V )1 . C 6�
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 017-092-30 '5 )-a -7"113
Property owner(s)
Stanley Masneri Day phone 440-1771
Mailing address PO Box 110230
Site address 6100 E 142nd Ave
Legal description (Sub'd., Block & Lot) Bunny Slopes Lot 1
Legal description (Township, Range & Section)
Lot Size 76,500 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(®all that apply)
Single Family (SF) 111Absorption Field r] Initial ❑ (w/wo ADU)
Septic Tank I I Upgrade n Duplex (D) ❑
Holding Tank 1 I Renewal ❑ Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage f 1
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: J cc,° p Waiver Fees:
-
Date of Payment: - I c.- 0 Date of Payment:
Receipt Number: O O 5 t Receipt Number:
Permit No. 05f l?I. C) 2- Waiver No.
Permit App_2-
09/0/Y) J
PO BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
April 18, 2018
Municipality of Anchorage
Development Services Dept- On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Bunny Slopes Lot 1 – 6100 E 142nd Ave
Septic trench design and permit application
Dear On-Site Services Engineer:
The septic system on the above lot has failed, so we are submitting this permit application for the
construction of a trench. The existing tank is concrete, and we have verified its integrity. The
attached site plan identifies the location of the home, well, existing septic location as well as the
proposed trench. No conflicts exist between this proposed system and any other well or septic
system, whether on this lot or adjacent lots.
The ground surface on the lot is flat where the house sits, but on the rest of the lot slopes mildly
toward the south and west. The slopes do not exceed 15 %. There are no slopes greater than 25%
within 50 feet downslope of either the primary or alternate site. Drainage arrows are shown on the
site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic
system.
The new trench will be constructed parallel to the slope as much as possible. It will be a minimum
of 100’ from all wells and surface water, and more than 5’ away from the septic tank. We will
install a bull-run valve to allow the existing trench to recover and be used as an alternate site.
Please refer to the attached test hole logs, soils lab analysis, plan and profile pages for the septic
design. If this design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
4/18/18
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP181052, Deb Wockenfuss, 04/25/18
deckAsphalt
8
1
8
.
0
816
.
0
8
1
4
.
0
81 2.0
808.0806.0804.
0
80 2.07.6%8.4%7.4%10050 0
FEET
1"=50'
48' LONG x 3' WIDE, 6' EFFECTIVE
DEPTH ABSORPTION TRENCH 3-BD R M HOMEEXISTING WELL
EXISTING 1250-GAL
CONCRETE TANK
NOTE:
NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE
PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
SYSTEMS.
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FD - FLOW DIVERTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
CO
MT
TH
BUNNY SLOPES, LOT 1
Apr 25, 2018
SLOPES > 25%
SLOPES > 46%
E. 124nd AvenueCL PICKETT STREETCLRock wall
10' Utility Easement
EXISTING
TRENCH
UNDEVELOPED UNDEVELOPEDUNDEVELOPED
WELL > 100' FROM PROPERTY LINE
CO
FD 2CO
EXISTING CRIB
(EXACT
LOCATION
UNKNOWN)
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP181052, Deb Wockenfuss, 04/25/18
BUNNY SLOPES LOT 1
DESIGN FACTORS: SYSTEM REQUIREMENTS:
450 GPD PEAK FLOW
PERK RATE: 12 MIN/IN
APPLICATION RATE: 0.8 GPD/SF
3' WIDE DEEP TRENCH SYSTEM
1250-GAL SEPTIC TANK (EXISTING)
TYPICAL DEEP TRENCH SECTION
(NO SCALE)
4" PERFORATED PVC (HOLES DOWN)
DRAINFIELD ROCK
3'
6"
6"
4'
6'
Apr 25, 2018
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
BOTTOM OF TRENCH: 10.5' BELOW GRADE
FLOW LINE ELEVATION: 4.5' BELOW GRADE
TOP OF TRENCH: 0.5' ABOVE GRADE
0.8 GPD / 450 GPD/SF / 6' DEEP / 2 SIDES = 46.9 LF TRENCH REQUIRED (48 LF SPECIFIED)
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP181052, Deb Wockenfuss, 04/25/18
Rick Mystrom,
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
October 21, 1996
John A Mazneri
Geraldine M Mazneri
Revocable Trust
Masneri J A & G M/Trustees
PO Box 111793
Anchorage, Alaska 99511 1793
Subject: Lot I Bunny Slopes Subdivision
Permit #SW950346, PID #017-092-30
The subject permit, issued October 17, 1995 by this office for a
single family well and/or on-site wastewater system, has
expired as of October 17, 1996.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. Ail inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
SiCely, ~
J~,n~&¢ Cross, I~.E.
~ogram Manager
On-site Services
enc: Copy of Permit
cc: Anderson Engineering
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW950346
DESIGN ENGINEER:ANDERSON ENGINEERING
OWNER NAME:MASNERI JOHN A & GERALDINE M
OWNER ADDRESS:6100 E 142ND AVE
ANCHORAGE, AK 99516
DATE ISSUED:10/17/95
EXPIRATION DATE:10/17/96
PARCEL ID:01709230
LEGAL DESCRIPTION:
BUNNY SLOPES LT
1
LOT SIZE: 76500 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT:
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) .
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
October 16, 1995
Municipality of Anchorage
Department of Heath & Human Services
825 "L" Street
Anchorage, AK 99502-0650
Subject:
Lot 1, Block 1, Bunny Slopes Subdivision
Septic System Design
Impacts to Adjacent Properties
Dear On Site Services Engineer:
The absorption trench on the subject lot has failed and must be replaced.
We hereby request a permit to upgrade the system in accordance with the
attached design. A testhole placed on the lot revealed a medium graded
sand with a percolation rate of 12 minutes per inch. We are proposing to
place a wide drainfield with 4' of drainage rock beneath the laterals. A
total of 57' of trench will be required. A diversion valve will be installed
so the existing absorption system may be reused at a future time if it
dries out.
The topography of the lot slopes from north to south from 3% to 4%. It
also slopes from west to east at a rate of 2% to 5%. No groundwater was
found in the testhole at depths over 18'. The existing septic tank falls
within the 100' radius of the well, but it has grandfather rights since it
was installed in the early 1970s. If the tank is found to be leaking it will
be replaced with a new tank placed outside the well radius. No other
conflicts exist with other wells in the area.
If the absorption trench is placed in the location shown the following
statements can be made:
The system, if constructed as designed, will have no adverse impact
on the wells in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact
on existing septic systems in the area or those to be constructed in
the future.
Lot 1, Block 1, Bunny Slopes Subdivision
October 16, 1995
Page Two
The system, if constructed as designed, will have no adverse impact
on reserved space, either surface or subsurface, on any lots located
in the area.
The system, if constructed as designed, will have no adverse impact
on drainage patterns in the area. The current drainage pattern will
be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
LOT 1', BLOCK 1, BUNNY SLOPES
SITE PLAN
SCALE 1" -- 50'
300.43
NSB'54'Og"E
252.38
30
IIm
L '-- ~so.oo__.
J 10' Ttlecom & £
.',
I"-..~'J
s8g,,*48'lg"E _
LOT 1; BLOCK 1, BUNNY SLOPES
JOB
SHEET NO.
CALCULATED BY
CHECKED BY
SCALE
OF
DATE
DATE
......................................... : ............................. SYSTEM PLAN
......................................... : ......................... SCALE 1" = 20'
............ NOTE:
Verify the Integrity of the Existing Concrete Septic Tank. -
Place Diversion Valve at Intersection of Old and New Trenches ....
Place Two New Post Tank Cleanouts. ..
P~OOUCT 2~4-1 ~ngm She~) 205-I (Pmd~d) t(~ inc Gnmlea Ma~. 01471 TD O~dif PHO~ TOLL
LOT 1, BLOCK 1, BUNNY SLOPES SUBDIVISION
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Three Bedroom Home
Perc. Rate: 12 Min./In.
Application Rate: .8 GPD/SF
Reduction Factor: .5
Shallow Trench System
1,000 Gallon Tank (Existing)
4' Gravel Beneath Dist. Pipe
3 Bdrms. X 150 GPD / .8 GPD/SF = 562.5 SF of Absorption Area
562.5 SF / 5 LF X .5 (Red. Factor) = 57 LF Total Absorption Trench
Therefore: Construct a Shallow Wide Absorption Trench System With a
Total Length of 57 L.F. Distribution Pipe Placed at 5' Below Ground
Surface. Verify the integrity of the existing septic tank and resuse if
acceptable.
NOTE:
TYPICAL WIDE TRENCH SYSTEM
(NO SCALE)
Bottom of Trench to be 4' Above Groundwater.
Grade Area Over Trench to Drain
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L' Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCR,PT,ON: ~1t t~, l~lS~'l' ~
r~/~.
1
2
9
10
11
12
13
14
15
16
17
18
19
20
COMMENTS
SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Depth
to
Water
Menitoring?
Gross Net Depth to Net
Reading Date Time Time Water Drop
' 3';~ 1~5,~ ~.-~ ~,'/~
PERCOLATION RATE I ~ [m~nutes/,nch) PERC HOLE DIAMETER
TEST RUN BETWEEN - 7 FT AND -- ~ FT
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
THAT TTIS TEST WAS
PERFORMED IN
72-008 (R~. 4/85)
GREATER ANCHORAGE AREA BORL, GH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME ~
LOCATION.
MAILING ADDRESS ~¢-X ~'~-~ ~ i~A
LEGAL DESCRIPTION LOT I
PHONE
SEPTIC TANK:
DISTANCE ,
FROM WELL
INSIDE LENGTH
MANUFACTURER ~.A t~-~/~]
INSIDE WIDTH
~ MATERIAL
LIQUID DEPTH
NUMBER OF
COMPARTMENTS
LIQUID CAPACITY /~O GALLONS.
SEEPAGE llil~:'-r
NUMBER OF PITS
DIAMETER
OR WIDTH__, LENGTH , DEPTH
LINING MATERIAL
BUILDING FOUNDATION
ADDITIONAL ABSORPTION
CRIB SIZE: DIAMETER__DEPTH DISTANCE FROM: WELL
TOTAL EFFECTIVE
NEAREST LOT LINE__ ABSORPTION AREA (WALL AREA) ,<~-'C
SQ. FT.
WELL:
BUILDING--) /--~ NEAREST NEAREST
FOUNDATION _'t~U LOT LINE SEWER LINE
CESSPOOL , OTHER SOURCES
APPROVED DISAPPROVED REMARKS
DEPTH DISTANCE FROM:
SEPTIC gt~I SEEPAGE
, TANK , SYSTEM
DISTANCES:
INSTALLED BY: ~)~'~ ~)
REMARKS:
DIAGRAM OF SYSTEM
j\
APPROVED
G.A.A.B.
GREaI __.R ANCHORAGE AREA bOr 'gh-~/'~ --;'~
PERMit NO.
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 "E" STREET ANCHORAGE, ALASKA 99503
TELEPHONE 274-4561
SEWAGE DISPOSAL SYSTEM APPLICATION AND PERMIT
INSTALLATION LOCATION
'EGAL DESCR,PT,ON '
INSTALLATION Of: SEPTIC TANK
TYPE AND SIZE OF FACILITY TO BE SERVED
FINANCED THROUGH ~2~~d
SOIL TEST RESULTS t
COMPLETION DAte ANtICIPAtED
~ sEE2GE PIT v DRAIN FIELD
TO BE INSTALLED BY
FINAL INSPECTION: 24 HOUR NoTIce REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTA QUIREM S
FOUNDATION TO SEPTIC TANK ~~--~~~
FOUNDATION TO SEEPAGE PIT , DRAIN FIELD
TYPE
DIAGRAM OF SYSTEM
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK , SEEPAGE PiT
TO NEAREST LOT LINE. ~ /
WELL TO SEPTIC TANK -
DRAIN FIELD / ~ /r
WATER MAIN TO SEPTIC TANK
DRAIN FIELD
., DRAIN FIELD
SEEPAGE PIT
ALSO CONSIDER AREA WELLS.
SEEPAGE PIT
SEPTIC TANK, , SEEPAGE PIT , DRAIN FIELD
TO RIVER, LAKE, STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBed SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
BOROUGH ~
LICENSED DESIGNER
I CERTIFY THAT I AM FAMILIAR WITH THEJ~IIREMENTS OF GREATER .~NCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DES SY AC r A CE~WiTH SAID CODE. -- //
:2TRM NO, EQ_0, $ PLICANT'S SIGNATURE7
SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT
Legal Description_ 'F L,,~ ,, N~ ,,
!
Application to Install: Septic tank _ eepag,e plt Drain field__, Other
To Serve the Following Facility._ 3
Financed Through ~J44~,,~ ........ To be Installed
Percolation Test Results_ , .......... ~tieipated Dat. of Co~let~m_.
BELOW T0 BE FILLED O~ BY ~ALTH DEP~T~NT
~ ,,, . permit to install a
' "
- _ ~~__as descmibed ~elow. Size of ~t
__~0~ · ~tic tank size. /~ Type ~,,S~page ~ea
DISTANCES:
DIAGRAM OF SYSTEM
I certify that I am familiar with the requirements of Greater Anchorage Area Borough
Ordinance No. 28-68 and that the above described system is in accordance with said code.
T.H. -1
8-21-75
ORGANICS w/TRACE SILT
SILT, TRACE aAHD
0.0w
3.0~
SAND, SOP1E SILT
(SP-SM 200 sq. ft./bedroom)
6.0'
INT.E~YE~ OF SANDY
NO WATER TABLE
20.0' T.D.
Log represents
Lot 1, Block 1
Bunny Slopes
Subdivision
R Consultants Inc.
ANCHORAGE FAIRB'ANK$
ALASKA
John Masneri Property
Log of Test Hole
Anchorage, Alaska
Parcel I.D.
4.
Complete legal description Bunny Slopes LOL -1 I
Location (site address)
Current Property owner(s)
Mailing address
Real Estate Agent
Expiration
B 9 70
10 77
\_S A F€
/A\J)
0
M�00-qwwm
Stanley M. Masneri Day phone (907) 440-1771
PO Box 110230 Anchorage AK 99511
2. TYPE OF DWELLING:
Fx-1 Single Family (w/wo ADLI)
❑ Duplex
F-1 Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: -3
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
Z
Individual
El
Individual Water Storage
D
Holding Tank
1-1
Community Class Well
0
Community
0
Public Water System
E]
Public Sewer
0
WaiverNariance request for: Distance:
Received by: I Date:f
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 5-1-121M
Date of Payment -Z/I/ a 16
Receipt Number 6 L3wn
COSA # 1"?U 9 11
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
Cl /I
1 -zi 1
As certified bymyseal, affixed hereto and as of the validation date shown below, |verify that myinvestigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this app|icebon,
shows that the on-site water supply and/or wastewater disposal eysbano is (are) aefe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(ore) in compliance with all applicable Municipal and State codes,
ordinances, and regulations ineffect atthe time ofinstallation.
Name OfFirm
Address PO
Engineer's Printed Name Michael Anderson, PE
6. DSD SIGNATURE
System #1 Approved for bedrooms
Disapproved
~�
��ond�ioDo|approval for --]
Phone (9O7)522-7773
Date 4/23/18
bedroorne, with the following stipulations:
`
Original Certificate Date:
The Municipality ofAnchorage Development Services Division (DSD) issues Certificates ofOn-Site Systems Approval (CO8A) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered inthe State ofAlaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
COGACheokkst X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
on»xblue sheet -C *' � "
Bunny Slopes, |nf1
Legal Description: `^ ~ ^^'"'� ' ^-"` '
A. WELL DATA
Well [�['v�t�
type Private IfA,[lorCprovide PWS |D#__
10/04/68
Da�uom�e�d Sanitary seal (YIN) \/
Total depth _12O ft. Cased to 120** ft�
FROM WELL LOG
Date uftest '~'~ 1O/D^1"/°~��
�
Static water level `~��~ ft.
�
Well production ° 9 -P.M.
WATER SAMPLE RESULTS:
O
Co|iColiformno|onias/10OmL Nitrate _,309 mQ/L
35.7 4/18/18
Arsenic — ug/L Date of sample. —
Ifmore than fseptic system ioonthe lot:
COSAChecklist # —of
___
Structure served bythis system
Well Log (//N)Y
Wires properly protected (Y/N)_,______.
Casing height (above ground) 16 in.
AT INSPECTION
4/21/18
R�
_� ft�
Collected by: Forge
�p O�rrpt� 5
TankTvpe8No�hpd`�~~�""'`� ~'~~~ O��in����`��^�.^�
1250 1 YTanke�*_.�°�^'_gm|� Numb�rof<�onnpo�ments_^C|eonouba/YYN)_,____
Foundation cleanout (Y7N)N N Depression over tank (Y/N)_~,__ High water alarm (Y/N)_
Date of pumping 5/26/2018 Pumper Around The Clock Pumping
71
Date installed 5/26/18 Soil rating (g.pdm2or*u«`drnl) ]8GPD/SF System type Deep Trench
Length 48 ft. Width 1'5 ft. Gravel belowpipe A
ft.
108 �7� `/ NTota deoth~fL E�aboorpdonarea .ft~ yNonUohngtube __.__ Depression over fi�d_~,_
Date ofadequauytest New Const. Reauho(Pasa/Fai()For bedrooms
Fluid depth inabsorption field before test in. Water added— gal. New depth in.
Elapsed Time: min. Final fluid depthin. Absorption rate >= g-p.d.
Any rejuvenationtreatment (past 12mo.)(YIN &type) |fyes, give date
________
D. LIFT STATION
Date installed___
"Pump on" level ad
Datum
_ Size in gallons __
in. "Pump off" level at
_ Cycles tested
ff
K8anho|o/Aooess(//N)_______
High water alarm level cd____
Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
WELL 0NLOT TO:
**�
8eptictanW|ift station��'�=1/l0/
on lot "~ On adjacent lots ' ~=
/
Absorption > 1�O/
on�e|don|Vt '=� <]nadjacent lots > '~~ 1DM
/7�'
Public uevvermain �p' ~ Public eevvermanhole/cleanout >100''°°1OO
'' ~ ��>75'
Animal
service line >^- Holding tank ' ~^
^
Anima|oontainnnentareas >50' Man ure/an imal excrete storage areas >100/
SEPTIC/HOLDING TANK {)NLOT TO:
�
Building foundation >~/
n Property line >51
[1' VV
Water main >1 '" aterservice line >1O/
Wells onadjacent lots >1OO'____.,~^°___
ABSORPTION FIELD {}NLOT TO:
Property> 1O/
|ine '~ Building foundation >10/
/
VVaterService line >10/ 8u��1DO
aoewahar '�~
0OO�� yJ��f��
Curtain drain None Noted = VVe||a on adjacent lots >1OO'
Absorption field >9
Surface water >1OO/
Water main >1/Y
Dhveway, paddng/vehicleetom�,1O/ge�_��
F. COMMENTS
New absorption trench installed. Old system connected with diverter valve.
**Casing depth aSSUOOed from
information recorded OOwell log.
+*+F[OrDmost recent surveyor aSbuilt.
G. ENGINEER'S CERTIFICATION
/
certify that /have determined through field inspections and
review of Municipal records that the above systema are in 49 Id.
conformance with MOA COS4guidelines /neffect unthis date.71
K�'��B��| /\D�6�[�D� ���� �
Engineer's Printed Name Michael " ' ` ° ' ' `Michael E. Anderson
-
R/12/18
Date
in.
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT (• jr1.7) 907-343-7904
On-Site Water and Wastewater Section Fax: 343-7997
www.muni.org/onsite
Arsenic Advisory
Certificate of On-Site Systems Approval # osc181175
Subdivision: Bunny Slopes, Block: , Lot: 1
A water sample revealed an arsenic concentration of 35.7 micrograms per liter
(ug/L). The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. information on arsenic is available from the On-Site Water and
Wastewater Program website (www.muni.org/onsite) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On-Site
Systems Approval.
Mailing Address: P.0. Box 196650 *Anchorage,Alaska 99519-6650 *www.muni.org
Municipality of Anchorne
P.O. Box 196650 0 4700 Elmore Road
Anchorage, Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997
http://Www.muni.org/Onsite
Develoiument Services Department
On -Site Water and Wastewater Section
Waiver#: OS1t181xxx COSA#: OSC181175 Permit#:
PID#: 017-092-30
Legal Description: Bunny Slopes Lot 1
so a-- 11 *
Applicant: Stanley Masned
i} Ct2t
Ag
Your request for a waiver of the required 100 feet horizontal separation from the septic tank to
the private well has been approved. The approved separation distance is 95.0 feet. Condition has
existed for at least 43 years and water sample results do not indicate that tank is affecting the
water quality of the well.
This waiver approval applies to the existing septic tank only. Any future upgrade to the on-site
wastewater disposal system will require all separation distances be met or another approval from
this department.
.. M a 2 a. a a M a z 2 M M M a a a a a a a a a a a a a a 0 a 9 a a a z M K 0 M M 2 X a 2 a a a a a a a a a a a a a a z 0 M 2 ff a M a a a a a a a a a a a I
Waiver is Granted: X Waiver is not Granted:
Date: Approved by:
Name of Reviewer
a a a M a M M a a a a a a a a M a N 8 a R a B H a H 2 a a a a a M 2 M a M a a I
'M" , V"'. A
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
Parcel I.D. #
0i'7
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
~'~ .~',:-.~' NAA#
GENERAL INFORMATION
Complete legal description
Location (site address or directions)
Property owner
Mailing address
Lending agency
Mailing address
~[_~ :,~r c,~. " Day phone
,
~ ....· ~, f.;,, Day phone
Agent
Address
Day phone
2, NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Unless otherwise requested, HAA will be held for pickup.
Individual well
Community well
Public water
NOTE:
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
NOTE:
Individual on-site
Holding tank ~
Community on-site
Public sewer
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72.025 Rev. 1/91) Front MOA~*21
STATEMENT OF INSPECTION BY ENGINEEi:I
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
NameofFirm / ~/~'~/ ,J ~-~".,-.L~;,'~Y ~--- Phone c-~-~ c7/~
Address "~ ~> I.,~ /~'-~/
Engineer's signature ~ ~.c~f.--~-~ Date ~'~c~,J¢2'~-.,/~1
/
/~S SIGNATURE
. Approved for
bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
Additional Comments
By:
Date
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements, Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued, The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-025(Rev, 1/91) Back MOA#21
Municipality of Anchorage
Department of Health & Human Services
HEALTH AUTHORITY APPROVAl. CHECKI.IST
LegalDescription: L~.~T'I, t~-.-./ ~i~t>,~ ParcelI.D. ~J-]
A. WELL DATA
Well type ~-- -g ~
Log present (Y/N)
Total depth
Sanitary seal (Y/N)
If A, B, or C, attach ADEC letter. ADEC water system number ~//~
Y' Date completed I0/~/~.~ Driller
i ~ Cased to ! ~ Casing height ;,~-~
Wires properly protected (Y/N)
Date of test
Static water level
Well flow
Pump level
SEPARATION DISTANCES FROM WELL TO:
FROM WELL LOG
g.p.m.
Septic/holding tank on lot
Absorption field on lot
Public sewer main
Sewer service line
AT INSPECTION
; On adjacent lots
; On adjacent lots
Public sewer manhole/cleanout
Petroleum tank
WATER SAMPLE RESULTS:
Coliform
//0/.[/
Date of sample:
Nitrate
Collected by:
Other bacteria
B. SEPTIC/~ TANK DATA
Date installed c~ ,-~',Z-;7~-~
Cleanouts (Y/N) /
High water alarm (Y/N)
Date of pumping
Tank size / ~ J)-O Compartments
Foundation cleanout (Y/N) ~ Depression (Y/N)
'h'///~- Alarm tested (Y/N)
~/~/~i Pumper A JI-'
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot 'i~.')
To property line
Surface water/drainage
On adjacent lots ~'/g~-~' Foundation
Absorption field /7/(~ Water main/service line
72-026 (Rev. 7/91) Front CONTINUED ON BACK PAGE
C. LIFT STATION
Date installed
Manufacturer
Size in gallons
Manhole/Access (Y/N)
Vent (Y/N)
"Pump on" level at
"Pump off" level at
High water alarm level
Cycles tested
Meets MOA electrical codes (Y/N)
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot
On adjacent lots
Surface water
D. ABSORPTION FIELD DATA
Date installed
Length ~ ~>~ Width
Total absorption area ,--~4
Depression over field (Y/N)
Results (pass/fail) '~
Peroxide treatment (past 12 months) (Y/N)
Soil rating /~-t'~ System type
Gravel thickness /0 /
Total depth
Cleanouts present (Y/N)
Date of adequacy test lO/b?- "5
for ~ bedrooms
~ If yes, give date
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot /~'~ '''~
To building foundation
On adjacent lots ~ ~:~
Surface water
Curtain drain
On adjacent lots ~/0~-2 Propertyline ~ ~
To existing or abandoned system on lot ~///~
Cutbank ~//A Water main/service line
Driveway, parking/vehicle storage area J. ~
E. ENGINEER'S CERTIFICATION
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effrr~.n~,r.,.t on the.. ~..date of this inspection.
Signature
Engineer's Name I~ - i. ~I'~, [F~[~i4_~9.~ ~---
Date
HAA Fee $
Date of Payment
Receipt Number
Waiver Fee: $
Date of Payment
Receipt Number
72-026 (Rev. 3/91) Back MOA 21
John Masneri
P.O.Box 111793
Anchorage, Ak. 99511
345-1978
~nicipality of Anchorage
Health and H~nan Services
On Site Services Section
825 L St. #502
P.O.Box 196650
Anchorage, Ak. 99519-6650
Re. On site i~spection approval for lot 1 Bunnyslopes.
To whom it may concern;
Mr Tobben Spurkland, the P.E. in charge of our on site inspection
suggested that I write this note to explain the change in status of our
home from a four (4) bedroom house to a two (2) bedroom house.
The following changes have been made in the floor plan of our home.
1) One of the two bedrooms was converted and plumbed into a hot
tub room.
~2) The second bedroom has been set up as an exercise room
containing the following;
a) A Nordic Ski machine.
b) A Proform electric treadmill.
c) A weight bench and weight set.
d) A stationary bicycle.
e) A gravity exerciser.
I hope this satisfactorily explains the change J.n the number of
bedrooms in our h~me.
Sincerely
ohn t~asneri
Certified Well
Location....,?/.'. ................................................... , ...................................................... ,,.
~,,e ~om~,~...Z.'/....~. :.Z ............................................................................
Depth of well ................ .~- -~-.. ......................................................................................
Size of casing ..... .~. /(
Distance to water whil.e pumping .................... : ........................................... at rate
of ............. .~-.. ..................... :...gallons per hour.
Description of Formation. '"' from · : to '
-' - -'z ~'..': ~:' "-'~
~ ,
'\N~....,. i'ceftif~,.the,'abov~tru'&:'and'~otrect;:':::':'.'"-::~-.ii"':'i :'-" .....
o¢ ~ ~ ~o~.:~?_~.~ 0:.~.:~~ ........................................
~ .~; ,_~ ~x'~'~e.~~ ' .... Driller
$wafford Drilling
3401 Spenard Road
Spenard, Alaska
We advise you to attach this certificate to your deed.
~.03 ~ ~'51'1'{, ~IVENIJE
LD,7' 1 £L.WNY
203 WESl 15TH. AYENUE SUITE 206
ANCHDRAGE, ALASKA 99502-3904
(907) 279-3916
RESIDENTIAL WELL INSPECTION
LEGAL:
Lot 1 BLll']l"/y Slope S/D
LOCATION:
5100 E 142nd~ Ave
OWNER:
John Masher i
TYPE OF WELL: Pr'ivate~ Single F.'amily
WELL LOG AVAILABLE:
Yes
INSTALLATION REQUIREMENTS MET:Yes
WELL YIELD FROM WELL LOG:
Ga].lons per' Minute
PUMP YIELD FROM TEST:
Gal 1 ons per Mi nute
DATE OF INSPECTION:
TEST PROCEDURE: Well was pumped at a constant rate while the
dr awdown was mon i toted w i th an ac~ust i c
probe. At the beginning o~ the test water level was ~ound at 78
~eet below top o~ casing. At a pumping rate o~ 5 gallons per
minute the water level dropped down to the pump intake~ 99 ~eet
below top o~ casing. At that time 90 gallons had been delivered,,
The well recovery was monitored ~or 2 h~}ur's. Durin~ this time the
well recovered to 80 ~eet. 90% recovery.
This well c~an proctuce 800 gallons per day.
TEST FOR E.COLI AND TOTAL NITROGEN: Water' was tested ,For E.Coli
and total nitrogen on Oct. 15 and (]ct,, 23.
E.Co].i O. Total Nitrogen ND (None Detected).
Max. allcJwable Total Nitrc)gen 10 rog/1.
TEST RESULTS: Th i s
Municipality (:)f Anchorage.
well meet. s the r'equirements o~ the
The Municipal requirement -Fc~r well qlo~ is 150 gallons c,{ wa'tier
per bedroom per clay. This well exceed this requirement. The
assessment of the condi ti on c)~c the (.~e]. 1 appl ~m es only to the
cc)nditions as o-~ ti'ne day tested. The .Flow rate may change due to3
subsurface conditions that may not be observed ~r'om the sur~ace~
and changes in the land use and other the
aclui-Fer .Feeding the well.
20~ HEST 15¥H, ~VENUE SUITE 20&
~NCHOR~GE, ALASK~ 99502-~904
SEPTIC SYSTEM ADEQUACY TEST
LEGAL:
Lot 1 Bunny Slope S/D
LOCAT I ON:
5.1.00 E 142nd. Ave.
OWNER:
John Masneri
RES I DENCE:
Si n(..~l e [--ami
2 Bedrooms
WELL:
Private: On Site
SEPTIC SYSTEM:
FROM MUNICIPAL. RECORDS~' 4 Bedroom System
.... (") Gal One Compares.
TANK: Espinosa ~.x.~ .....
ABSORPTION SYSTEM: Lo~ Crib Trenc:h
ABSORPTION AREA: 500+ Sq,, Ft.
SOIL RATING: 125
INSTALLATION DATE: 09/23/75
DATE OF LAST PUMPING:
A+ 09/09/91
DATE OF TEST:
October 23, 1991
TEST PROCEDURE: System was inspected and measured. Tank was
found with 4 feet of cover and with a liquid level of 52.5 inch-
es. Tr"ench clean []L~t was 5.5 ft. deep and dry. 6-inch trench
monitor tube was 16 ft. deep with 124 inches o-f water. The moni
tor may not be perforated.
340 gallons o-~ clean water" was added to the trench while the
water- ].evels in the tank and the monitor tube were monitored. The
water level in the tank did not change~ while the level in the
monitor rose 12 inches. The absorpt:i.~)n was monitored .~or 75
minutes. During this time the water level in the sump dropped
back to the pre test level, indicating that all the added water
had passed out of the system
TEST RESULT: This system meets the code requirements of
the Heal th and Social Services
Department of the Municipality of Anchorage.
NOTE The operat:ional life o-~ all septic systems depencls on the
local soil conditions~ groundwater levels that may fluctuate
dur':i, ng the year~ and the water usage of the family being served
by the system. These cond:i, tions are outside the control of the
eva]uator of this septic system. We can there.~;~:e_not give any
estimate o~ how lonq., thi=. system will ~unA~l'oO:;s~t~.~¢~actory.. .., ,. .~
czLtrrent c)r future c)ccupants. ,;.~ '~'-~'~ ... ,, ~, ,,,.
Legal
Owner
Client
Test
T.D.B.T.P.
LLA. B.
S.U.
~T,,P.
ARCTIC SPECIALTIES AND SUPPLY
Serving Alaskan Engineers with Well and Septic Adequacy Tests and Soil Percs since 1986
P.O. BOX 771747 e. EAGLE RIVER, ALASKA 99577 · TELEPHONE (907) 694-7112
Phone
Phone
Date
zT
MUNICIPALITY OF ANCHORAGE Y~~4~
DEPARTMENT OF HEALTH & ENVIRONMENTAL PRO7 ECT~IC[PALiTy ~:
825 L Street- Anchorage, Alaska 99501 DEPT. OF : ~ .L, :
ENVIRONMENTAL ENGINEERING DIVISION
Telephone 264-4720 AU0 2 ~5
J~ J-JFJJl p J J
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PROPERTY OWNER PHONE
~AI LI~ADD~ ESS
PROPERTY RESIDENT (If different from above) PHONE
PHONE
2. BUYER
MAILING ADDRESS,
3. LENDING INSTITUTION~' J PHONE
MAILING
ADDRESS
PHONE
4. REALTO~ENT
MAILING ADDRE88
/9/c'e s T
5. LEGAL DESCRIPTION
L,,/
STREET LOCATION .
6. TYPE OF RESIDENCE
S
INGLE FAMILY
[] MULTIPLE FAMILY
7. WATER SUPPLY
INDIVIDUAL~
COMMUNITY
[] PUBLIC UTILITY
NUMBER OF BEDROOMS
[] One [] Four
[] Two [] Five
[~ Three [] Six
f -
[] Other
* ATTACH WELL LOG. A well log is required for ail wells drilled
since June 1975. For wells drilled prior to that date, give welt
depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
INDIVI DUAL/ON-SITE~*
PUBLIC UTILITY
**If individual/on-site, give installation date ( ~ 71~'
If system is over two (2) years old an adequacy test is required
by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010(3~78)
THIS SIDE FOR OFFICIAL USE ONLY
TIME
I NSPECTI ON APPOI NTM ENTS
TIME
DATE RECEIVED
TIME
DATE DATE DATE
NSPECTOR INSPECTOR INSPECTOR
DIRECTIONS:
NUMBER OF BEDROOMS
1. TYPE OF RESIDENCE
[] SINGLE FAMILY
[] MULTIPLE FAMILY
[] ONE [] THREE [] FIVE
[] TWO [] FOUR [] SIX
[] OTHER
2. WATER SUPPLY
[] INDIVIDUAL
[] COMMUNITY
[] PUBLIC UTILITY
Connection Verified
3. SEWAGE DISPOSAL SYSTEM
E~ INDIVI DUAL/ON -SITE
[]PUBLIC UTILITY
Connection Verified
E~Septic...Ta[~k_or [] Holding Tank
Size: I ',.~_~-O If Tank is homemade
give dimensions:
TYPE OF TANK
TOTAL ABSORPTION AREA
4. DISTANCES
WELL TO:
Absorption Area to nearest Lot Line
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
PERMIT NUMBER
DATE INSTALLED
INSTALLER
SOILS RATING
INearest Lot Line
5. COMMENTS
(~APPROVED FOR ~--~ BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[] DISAPPROVEDBY (~) ~//
DATE
LEGAL DESCRIPTION
72-010 (Rev. 3/78)
2.49 EAST 515T AVENU~'''
CONSULTANTS, INC.
P.O. BOX 6087 ANCHORAGE, ALASKA 99503 TELEPHONE D07-~'79-0483
I"A! I'{B AN K.'$
JIJNE.%Li
TELEX 090-35419
August 22, 1975
R & M Ho. 5620913
John Masneri
SRA Box 456
Anchorage
Alaska 99507
RE: Test Hole and Soil Log Report for Sanitary System
Lot 1, Block 1, Bunny Slopes Subdivision
Dear Mr. Masneri:
We are submitting herewith the test boring results and our comments regard-
ing soil conditions encountered at the subject site. This investigation
was performed in accordance with your request of August 21, 1975, and those
procedures outlined in a letter dated July 15, 1975, by Rolf Strickland of the
Greater Anchorage Area Borough Department of Environmental Quality.
A single test hole was put down within the Lot 1 area for the purpose of
defining general subsurface soil conditions for the proposed sanitary
system. Excavation was accomplished with an auger type drilling rig and the
test hole was extended to a total depth of 20.0 feet below ground surface.
The final log prepared for the test hole has been included in Drawing A-01.
Ground water was nog encountered in the test hOle.
We appreciate being given this opportunity to be of service to you. Should
you have any questions with regard to the above, please do not hesitate to con-
tact us.
Very truly yours,
R & M CONSULTANTS, INC.
Vice President
JWR/ja
xc: GAAB