HomeMy WebLinkAboutBROOKWOOD BLK 4 LT 10
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
Date Received August 23, 1976
Time of Inspection
Date of Inspection ~-.~j[])-~./~~/
,-%
REQUEST
FOR
Cony.
Approval requested by: % Dynam~c Rea~lty
Mailing Address: 501 west Northe~l~ Lights
Property Owner: Ronald Lita]i~n
Mailing Address: Star Route ~/Box 1535X 99507
Dale Hopkins
Phone: 279-7611
Phone:
3. Legal Description: Lot 10 Bl~ock 4 Brookwood Subdivision
4. Location: Rainbow ~venue, off of Huffman
5. Type of facility to be inspected Single Family
6. Well Data:
No. of 6edrooms
A. Type Individual B. Depth
C. Construction
D. Bacterial Analysis
Sewage Disposal System:
A. Installed 1974
On-site system
B. Installer
C. Septic Tank:
D. Seepage Pit:
1. Size
1. Absorption Area
2. Manufacturer
2. Material
E. Disposal Field: Total length of lines
8. Distances:
A. Well to: Septic tank
, Absorption area
, Sewer Lines
Nearest lot line
, Other contamination
B. Foundation to septic tank
Absorption area
C. Absorption area to nearest lot line
EQ-034 (1/74) Page 1 of two pages
1. Type of Inspection:
2. Property Owner: ../~" ~/,/~"-~, . .~,~,~r~
Mailing Address: .,~/~,~ ~ l ~ ~ i' ~
3. Name of Buyer:
Mailing Address:
MUNICIPALITY OF ANCHORAGE UI"~' OF ANCHO~NG' E
3330 "C" Street, Anchorage, Alaska 99503 - 274.~i~ONMEN~AL
REQUEST F R APPR VA' -
O O LOF
INDIVIDUAL SEWER and WATER FACILITIES
CMRO VA FHA CONV
4. Name of Lending Institution:
Day Phone
Mailing Address: Phone
Name of Realtor or Agent: _.~.~,~_.~ ~4~,~' ~
Mailing Address: .-~'"~ J /_.x~. ~Ja-~_~/~,t,m ~/t~ ~/~ _,L~ Phone ~"7~//
Legal Description:
Location: ~
Type of Facility to be inspected:
Water Supply
Type of Supply: Public Utility
If Individual, number of dwellings presently served
If Individual, depth of well ~,~_ .~. ·
No. Bdrms.
Individual
Sewage Disposal System
Type of System: Public Utility
If Individual, date of installation
Individual (on-site)
EQ-037 (1/74)
Page 2 of two pages - Re( Jt for Approval of Individual S r & Water Facilities
Legal Description Lot 10 Block 4 Brookwood Subdivisio~
'
Approved~ ,~ · Disapproved
Approval Valid for one year from date signed
Greater Anchorage Area Borough, Department of Environmental Quality
Date
DIAGRAM OF SYSTEM
I certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED
Date
EQ-034 (1/74)
172
m\ \
HUF'FM,qN
II
F/oo 11
II
//'
//
/ /
163
171 ~:~)~ 173
178
Rabbit Creek Area Reference Map-P13
1974 JH
R & M CONI~ULTANTS, INC,
September 9, 1976
MUNICiPALiTY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL pRO1'[C. TION;
SEP 0 976
RECEIVED
Department of Environmental Quality
Sewer and Water Section
2518 E. Tudor Road
Anchorage, Alaska 99507
Attn: Lara Harrison
Re: Percolation Test on Existing Disposal System
Lot 10, Block 4, Brookwood Subdivision
Dear Ms. Harrison:
Enclosed is a copy of the results of the percolation test which was
conducted on the septic system located on the above described lot.
Please inform Mr. Dale Hopkins of Dynamic Realty of your conclusions.
If you should have any questions concerning this test or this letter,
please do not hesitate to call.
Very truly yours,
R & M CONSULTANTS, INC.
Junior Engineer
EY/sc
Enclosure
ANCHORAGE FAIR~=AN K8 JUNEAU
R &IV1 CONSULtANtS, INC.
September 8, 1976
'"U~MENTAL PROTECTION.
SEP 1 0 ;g76
. .o. RECEIVED
Mr. Ron Litalien
Star Route A
Box 1538X
Anchorage, Alaska
99507
RE: Percolation Test On Existing Disposal System;
Lot 10, Blk 4, Brookwood Subdivision
Dear Mr. Litalien:
On September 2, 1976, at the request of Mr. Dale Hopkins of Dynamic
Realty, our office conducted a percolation test on the septic system
located on the above described lot.
The following table represents the level of the liquid in the septic
tank. The depth of the tank was 9.6 feet below the top of the vent.
The depth of liquid in the tank was initially 4.4 feet above the bottom
of the tank and 5.2 feet below the top of the stand pipe. The tank had
not been pumped prior to the test and was, therefore, assumed to be at
the outlet level. For the test, the liquid level was measured from the
top of the stand pipe.
Summary of Measurements
Level of Liquid M~ter Reading
Time In Septic Tank in Gallons Remarks
11:40 5:16 0 (initial)
1:13 5:02 50
3:21 4:00 155
4:30 5:01 155 (final)
Fill Storage
Start Test
105 gallons
105 gal/197 min =
0.53 gpm, End Test
The meter used during the test was a Neptune 5/8" standard water meter
which was borrowed from the Anchorage Water Utility. The meter had
previously been calibrated and approved for' installation by the utility
company.
Since the house on the lot concerned was occupied, it can be assumed
that the leachfield in question was at its normal degree of saturation.
To further insure normal saturation and to fill any possible storage in
the system, 50 gallons of water were added to the septic tank before
beginning the percolate, on test.
ANCHORAGE FAIRBANKS JUNI~AU
Mr. ROn Litalien
September 8, 1976
- Page 2 -
If it is assumed that the existing three bedroom residence will house
six people, the average daily load on the disposal system can be expected
to be 450 gallons per day, or 0.31 gpm.
Since the existing disposal system accepted 105 gallons in 3.25 hours or
0.5 gpm, I would conclude that the leach field is presently performing
in an acceptable manner for a private residence.
It should be noted, however, that during the test, a small amount of
water entered the basement of the residence through a floor drain.
Because water did enter the basement with only a 105 gallon surge, it
can be assumed that the septic tank has a low surge capacity. Therefore,
care should be taken whenever surging the septic tank with a large
amount of water, i.e. washing clothes, bathing, etc.
If you should have any questions concerning this test or this letter,
please do not hesitate to call.
Very truly yours,
R & M CONSULTANTS, INC.
Junior Engineer
Ronald J. Rieland
Senior Engineer
EY/RJR/ddp
GREA' R ANCHORAGE AREA BOR("'$H
Department of Environment Quality
3500 Tudor Road
Anchorage, Alaska 99507
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATION
MAILING ADDRESS
LEGAL DESCRIPTION
PHONE
SEPTIC TANK:
D,STANCE t4
FROM WELL O//~//~'
INSIDE LENGTH
MANUFACTURER
INSIDE WIDTH
MATERIAL ,~:~)~r ~
NUMBER Of
COMPARTMENTS
LIQUI'D DEPTH
LIQUI'D CAPACITY/.~){~)O GALLONS.
TILE DRAIN FIELD:
DISTANCE FROM WELL ~/~/]' FOUNDATION ~2g///~
NUMBER OF LINES C>~ DISTANCE BETWEEN LINES
ABSORPTION AREA ~ O O SQ. FT.
DEPTH: TOP OF TILE TO FINISH GRADEC~ I
TOTAL LENGTH ·
NEAREST LOT LINE/~) ~/0 ~/~ OF LINES /25-
,TRENCH WIDTt~~ IN. TOTAL EFFECTIVE
DEPTH OF FILTER
MATERIAL BENEATH TILE c:~ 4
IN. ABOVE TILE
IN.
WELL:
TYPE
BUILDING
FOUNDATION
CESSPOOL
APPROVED
CONST RUCTION
NEAREST
LOT LINE __,
OTHER SOURCES
DISAPPROVED
NEAREST
SEWER LINE__
DEPTH
SEPT lC SEEPAGE
, TANK , SYSTEM
REMARKS
DISTANCE FROM:
DISTANCES:
SEWER LINE DEPTH:
PIPE MATERIAL:./
LOT SLOPE:
REMARKS:
Form PW*027
DIAGRAM OF SYSTEM
DATE/~//~.//ZTAPP ROY ED
GREATER ANCHORAGE AREA BOROUGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 "C" STREET ANCHORAGE, ALASKA 99503
TELEPHONE 274-4561
PERMIT NO.
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
,NSTALLAT,ON LODAT,ON g";--'J''-' - 7 --"' ....
-.6J
SEEPAGE PiT
TO BE INSTALLED BY
DRAIN FIELD OTHER
NOTEz THIS PERMIT !$ NOT VAl-ID WITHOUT SOU,. TEST
EGAL DESCR,FT,ON ZOT/O
INSTALLATION O;: SEPTIC TANK
TYPE AND SIZE OF FACILITY TO BE SERVED
FINANCED THROUGH
SOIL TEST RESULTS ~~~
COMPLETION DATE ANTICIPATED
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE
TYPE
MINIMUM DISTANCES, REQUIREMENTS,,,,-
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE PIT
., SEEPAGE PIT
DRAIN FIELD
-/
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK
TO NEAREST LOT LINE.
SEEPAGE AREA SIZE '"~"~/~' TYPE "~
SEEPAGE PIT
ALSO CONSIDER AREA WELLS.
WELL TO SEPTIC TANK
DRAIN FIELD
WATER MAIN TO SEPTIC TANK /'"~/ /
/
DRAIN FIELD
SEPTIC TANK,
f - - , SEEPAGE PIT
TO RIVER, LAKE STREAM.
DIAGRAM OF SYSTEM
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON pIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEl. BACKI~ilL.,L
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
G .A .A .B ·
OR
I. ICENSED I~ESIGNER
I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF (~REATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DATE _ _ . APPLICANT'S SIGNATURE
FORM NO, LQ-01 6
GrEATEr ANChOrAGE ArEA BOROUGH
~ ~)D]~ES~ HIEAI. TH DE:P~i~TMENT
td-7-s-s.v-~.c-er . F.o. Eox ~e
~27 [c~[e S~eet ANCHORAGE, ALASKA 99501
PHONE 272-6467
3~27 wear 7~th Aveaus
/achorage, Alaska
SUBO'ECT~ P~oposed On-Site
~ewage Disposal $Tstem
the ins~allati~ of a ~200-ga11~ ~q~d capaci~ septic
in co=i~c~i~ wi~~aqu~ feet of p~o~ly Installed seepa~
~a ~ a ~s of' sewage disposal fo~ a thee bedlam ho~
located ~ the s~je~t p:ope~=y.
This latter ia to ~e.~ve as preliminary approval. Final approval
will be ~anted upon completion of an on-site inspection by this
Department of the installed system prio~ ~o backfill.
Please contact us as much in advance aa possible to perfo~ the
The water system serving the subject property is the Brookwood
Subdivtsio~ community system which meets with the approval of
this Dapa~msnt,
-DAVID R. I,. DUnCAn, M, D.
~edtcal D~_~ector
BY:
Chief
Cnent /;f~', /- ? ?
ALASKA. TESTLAB
1940 Post Road
Anchorage, Alaska
Sheet / of /
v¢O No. /~g~o ,,
T.H. No. /
'~ Tech. _ %../, ~'.J
FHA No. .:.,~
Location, Lot /,Q -- ,Block , ,Subdivision · . · -
P~.,~com~oN ~s~
~,.',:.,~,.,...,..,,:.......:~.:.-?.~,.,....,~:.~.~..:, ......: ..... :,..,.:.~&.~.~:~ .... :....~. ~.,....: ....,..,..,:. .... ..,. :.: ...... . ....
Depth S
Feet Visual - Unified . Location Sketch
Reading
Date
Gross Time
Net
Time
Depth to H20
Net Drop
o
ADAMS · CORTHELL · LEE ° WINCE
&. ASSOCIATES
CONSULTING ENGINEERS
AFFILIATED WITH
A~ASKA TESTLAB
1940 POST .ROAI~ - ANCHORAGE:. ALASKA
TEL. 272-34~8
April 10, 1968
Work Order #8640
Mr. Lee Browning
3837 West 74th Avenue
Anchorage, Alaska
Subject:
Percolation Test - Lot 10, Block 4,
Brookwood Subdivision
Dear Mr. Browning:
A percolation test has been performed on the subject
lot. The test was performed in a test hole which had. been
· dug and saturated by you. The field test dataare shown on
the attached sheet.
The percolation rate was determined to be 1 inch per
approximately 5-1/2 minutes.
Very truly yours,
ADAMS, CORTHBLL, LBE, WINCB
~ ASSOCIATBS
Frank W. Wince,' P.E.
FWd/kc
Enclosures
^~rtl 17, 1~73
Feueral tfoustng. Administrai:ton
34,; ~.~esL Fifth Avenue
/~nchorage, Alaska 99501
Let 10, Lllock 4, Brookwood S/D
i~r. Lawrence Sebring i~as submitted a soil test to :his
...e~artm~nt an~ has been issued a per~i~ to install an on-
si t~ sewa~e syste~, for the subject lo:. lne lo: is serveu
~,y a co~:m~unity w~'ll.
Ti~e sewerage syste~: can be expected to function satisf~ctorily
if it is installed and maintained in aCcorOance with
~,~',.~ ~tate laws.
.,1 ncerely,
:~san L. Dickerson
Sanitarian
js
CC:
L~wrence Sebrin9
SRA Box 1540C
WILLIAM A. EGAN, $OVERNOR
SOUTHCENTRA£ REGIONAL OFFICE
MACKAY BLDG.
338 DENALI STREET
ANCHORAGE 9950J
c
SI, BJB : 10, Mock 4
We have revimced your situation in light of the interpretation of
the 40,000 Sq. Ft. -20,000 Sq. Ft. requircment contained in Section
18 AAC 72.030 of the Department of Environmental Conse'm~ation Waste
Water Regulations. It is our finding that since you had m.mership
of the lot on or before February 5, 1973 and that you intend to
construct a private residence for your personal use, that this particu-
lar Section of the %'aste Water Regulations is not applicable in your
case.
We would hmcever advise you that of course all existing BorOugh
Regulations are ~n effect and are applicable in all cases except
where State requirements are more stringent.
Kyle J. Cherry
Regional Envirm~mental Engineer
CC:
I~EC~.IVED
~P. EATER ANCHORAGE AREA BOROUGH
ADAMS * CORTHELL * LEE * WINCE
& ASSOCIATES
CONSULTING ENGINEERS
AFFILIATED WITH
ALASKA TESTLAB
1940 POST ROAD - ANCHORAGE, ALASKA - 9B501
TEL. 2?2-3428
April 10, 1968
Work Order #8640
Mr. Lee Browning
3837 West 74th Avenue
Anchorage, Alaska
Subject:
Percolation Test - Lot 10, Block 4,
Brookwood Subdivision
Dear Mr. Browning:
A percolation test has been performed on the subject
lot. The test was performed in a test hole which had been
dug and saturated by you. The field test data are shown on
the attached sheet.
The percolation rate was determined to be 1 inch per
approximately 5-1/2 minutes.
Very truly yours,
ADAMS, CORTHELL, LEE, WINCE
& ASSOCIATES
Frank W. Wince, P.E.
FWW/kc
Enclosures
RICHARD S. ADAMS, P.E. ALAN N. CORTHELL, P.E. HARRY R. LEE, P.E. FRANK W. WINCE, P.E,
L A S K A T E S T L A B Sheet
1940 Post Road WO No
Anchorage, Alaska Date
F~No. "- Tech. ' ~ ~
~cation', ~ /~ ,Block ~ ' ,Subdivision ' ~sS~~ m
3'
PERCOLATION TEST, DAT/~
Depth Soil Class
Fee t Visual - Unified
~eading
Location Sketc~h
Date Gross Time Net Time Depth to H20 Net Drop
Peroo~al
1 "/ . ,s- ',,.. : MinUte.
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" ~S. treet, Anchorage, Alaska 99503 274-4561
~%~r Date Received May 7, 1976
Time of Inspection
Date of Inspection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
1. Approval requested by:
Mailing Address:
2. Property Owner:
Mailing Address:
Dynamic Realty % Donita Gose
3380 C Street
Frank & Willa Konte
Star Route A Box 1538, 99507
Phone: 279-7611
Phone: 344-5017
3. Legal Description: Lc~ 11 Block 4 Brookwood Subdivision
4. Location: Rainbow Avenue
5. Type of facility to be inspected Single Family No. of bedrooms
6. Well Data: ~m~mm~mm~- ~~_~J~ (n ~r~~Ct~
A. Type ~~ ~~ B. Depth
e
A. Installed
C. Septic Tank:
D. Seepage Pit:
E. Disposal Field:
Distances:
e
C. Construction
Sewage Disposal System:
67-68
1. Size
1. Absorption Area
Total length of lines
D. Bacterial Analys~is
On-site system
B. Installer
2. Manufacturer
A. Well to: Septic tank
Nearest lot line
B. Foundation to septic tank
, Absorption area
, Other contamination
. , Absorption area
C. Absorption area to nearest lot line
2. Material
, Sewer Lines
EQ-034 (1/74) Page 1 of two pages