HomeMy WebLinkAboutBRUIN PARK BLK 2 LT 7Bruin Park Lot 7 Block 2 #016-102-14 z }. I DEC d Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171167 PID Number: 016-102-14 ❑ New Upgrade Name: TRAVIS & HEATHER REIER ABSORPTION FIELD ❑ Deep Trench El Shallow Trench El Bed ❑Mound Address 11026 FOREST DRIVE ✓❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 5 1.0 GPD/SF 5.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 1.5 Ft. Gravel depth beneath pipe 3.5 Ft. Subdivision Block Lot BRUIN PARK 2 7 Fill added above original grade 2.5 Ft. Gravel length 2@51 Ft. Township Range Section Gravel width 5.OFt. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 944 z Ft 2 10 Ft. Well 100.2 121.9 113.5 N/A 83.5 TANK El Septic r❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer ANCHORAGE TANK Capacity 2000Gal. Surface Water 100+ 100+ 100+I N/A Material Number of compartments Lot Line 57.5 20.0 68.8 N/A STEEL 2 NA Foundation 17.8 r28.3 37.4 N/A LIFT STATION Manufacturer Capacity Curtain Drain 50+ 50+ 50+ N/A ORENCO 500 Gal. Remarks Pump on level at TIMED in. Pump off level at in. High water alarm at 45in. Pump make and model P2005 Electrical Inspections performed by MOA BUILDING SAFETY Installer PIPE MATERIAL House to tank 3034 Tank to 3034 drainfield BEEKS CONTRACTING Drainfield 3034 CO/MT 3034 Inspector PANNONE ENGINEERING SERVICES BENCH MARK (Assumed elevation) 105.0 ft Inspection��' 12/19/17 nd dates: 2 12/21 /17 Location and description 3rd 12/21/17 4`h 12/4/18 BOTTOM TRIM AT POINT B COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp rG OF �4L,Qll�� Conditional Approval: Date -= ,o c� Steven ° °�annone Approved61Date110ff f CE 814c .• ... Vp 4 m6pecuon nepor[_ i- i- i t.coc Q. LES. I Q N PARAMETERS Z\ PRIMARY SEPTIC SYSTEM P 0 T 7 FC 37.1 24.3 L 38.5 NO. BEDROOM: 5 '750 gpd) TANK SIZE: 2,000g S.T,E.P. Ci 36.4 REM6VED TANK (E) PERC RATE: <1 MPI GRADE BREAK/ TOP OF SLOPE 48.1 R MOA CODE. STALLED 20OOg S.T.E.P. TANK /P SOIL RATING: 1 GPD/SF AREA ROD: 750 SF 59.1 SHED' W/ FC BEFORE CONNECTED TO END OF EACH FIELD SYS. TYPE: WIDE TRENCH— 3.5 ED RF:0.54 cl MIN LENGTH: 81 LF INSTALLED DRAIN FIELD USED: (2EA) 51 LF x 5.0'W x 3,5'ED x5T (2 EA) 51 LFx5'Wx3.5' E.D., 5.0' TD W/ 1,25"0 PIPE W/ HOI ES TOTAL AREA: 944 SF DRILLED 30" O.C. INSTALLED MT AT EACH END I 12.1\\ 105.2 J U LEE REID 1989 •/ WELL (E) RESERVE DRAIN FIELD REUSE EXISTING (BASED ON CAT 111) 38LF x 5'W x 35ED x 6*TD DRAIN FIELD DRAIN FIELD EXISTING GRADE 10% 2.5 15 Qt FILTER FABRIC 0 . - /ID RAI N ROCK 0 ABOVE INV 025 n,125, DRAIN I — O.G. TRENCH 1:100.0 TRENCH 2: 98,0 20009 S.T.E.P,3.5' DRAIN ROCK TANK I I \ 11 "I UtArNmur- I '> 7T5BR DRIVEWAY HOUSE (E) DRIVEWAY 00.2 0 1— z 0 F.G. TRENCH 1.5 102 TRENCH 2 100.5 TRENCH 2: 96.5 TRENCH 2: 96.5 TH PES (SOIL CONFIRMATION —T:T E-7 SP 10 11 12 � SOH DATE PERFORMED: I 9DECI 7 NOTES: PNE ENG SVC, LLC Date RECORD DRAWING P.O. BOX 102954 ANCHORAGE, AK 99510 12/12/18 PHONE (907) 272-8218 FAX (907) 272-8211Scale 1 60' BRUIN PARK B2 L7 P.I.D. NO TRAVIS & HEATHER REIER PERMIT NO. DRAWN ACP 11026 FOREST DRIVE A!.. CE 8149 OSP 17116 7 ANCHROAGE, AK 99516 Sheet 2 OF 3 A B FC 37.1 24.3 TI 38.5 35.1 T2 36.4 46.0 LS 36.2 48.1 M 1 45.8 59.1 24 83.6 50.6 M3 rM 58.1 72,5 M4 91,0 I 65.3 U LEE REID 1989 •/ WELL (E) RESERVE DRAIN FIELD REUSE EXISTING (BASED ON CAT 111) 38LF x 5'W x 35ED x 6*TD DRAIN FIELD DRAIN FIELD EXISTING GRADE 10% 2.5 15 Qt FILTER FABRIC 0 . - /ID RAI N ROCK 0 ABOVE INV 025 n,125, DRAIN I — O.G. TRENCH 1:100.0 TRENCH 2: 98,0 20009 S.T.E.P,3.5' DRAIN ROCK TANK I I \ 11 "I UtArNmur- I '> 7T5BR DRIVEWAY HOUSE (E) DRIVEWAY 00.2 0 1— z 0 F.G. TRENCH 1.5 102 TRENCH 2 100.5 TRENCH 2: 96.5 TRENCH 2: 96.5 TH PES (SOIL CONFIRMATION —T:T E-7 SP 10 11 12 � SOH DATE PERFORMED: I 9DECI 7 NOTES: PNE ENG SVC, LLC Date RECORD DRAWING P.O. BOX 102954 ANCHORAGE, AK 99510 12/12/18 PHONE (907) 272-8218 FAX (907) 272-8211Scale 1 60' BRUIN PARK B2 L7 P.I.D. NO TRAVIS & HEATHER REIER PERMIT NO. DRAWN ACP 11026 FOREST DRIVE A!.. CE 8149 OSP 17116 7 ANCHROAGE, AK 99516 Sheet 2 OF 3 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 TEST HOLE PES OR I ORGANICS BOH DATE PERFORMED: 12/19/17 SOILS LOG PERCOLATION TEST SLOPE SITE PLAN SHED TH —PES TH WAS GROUND WATER ENCOUNTERED? y IF YES, AT WHAT DEPTH? 12.0' DEPTH TO WATER AFTER MONITORING? DATE. SLOPE I u TH / 5BR HOUSE (E) / READING DATE CLOCK TIME WATER NET TIME LEVEL READING NET DROP 1 12/19/1-/ 10:40 - 5.900 - 2 0:44:304.5 MIN 10.900 5.00 3 10:45 5-900 - 4 10: 49: 5C 4.8 MIN 10.900 5.00 5 10:50 - 5.900 6 I 10:55:015.02 MIN 10.900 5.00 PEROLATION RATE 1.02 inch —JrnLin �P � TEST RUN BETWEEN 3 FT AND 4 FT COMMENTS: Test hole excavated by BEEKS CONTRACTING. Prec hole was presoaked. Test run for at least one hour. Last 3 readings reported, PERFORMED BY: DAN MORAN, I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. NOTES: PANNONE ENG SVC, LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 ... . .... .. ...... ........ . . annon CE 8149 Dote 12/12/18 RECORD DRAWING Scale NTS BRUIN PARK B2 L7 TRAVIS & HEATHER REIER 11026 FOREST DRIVE ANCHROAGE, AK 99516 P.I.D. NO 016-102-14 DRAWN ACP PERMIT NO. OSP1 71167 Sheet 3 OF 3 %, "'` MUNICIPALITY OF ANCHORAGE °. ° �r,cnt On-Site Water&Wastewater Program ca' s; PO Box 196650 4700 Elmore Road .f- Anchorage,Alaska 99519-6650 Phone.(907)343.7904 Fax:(907)343-7997 http.//www.muni.orgionsite epartmen1 44cwoaa6a On-Site Wastewater Disposal System Permit Permit Number: OSP171167 Effective Date: 8/8/2017 Work Type: Septic Upgrade Expiration Date: 8/8/2018 Tax Code Number: 01610214000 Site Legal Address: BRUIN PARK BLK 2 LT 7 G:2633 Site Mailing Address: 11026 FOREST DR, Anchorage Owner: REIER GERALD T & HEATHER D Lot Size in Sq Ft: 41600 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 5 This permit is for the construction of: 0 Disposal Field El Septic Tank ❑ Holding Tank 0 Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: A percolation test is to be completed at time of construction of the septic field to confirm the design percolation rate. Location of test hole shall be as shown on permitted site plan. If percolation rate is <1 mpi, a sieve analysis shall be done on the soil to confirm 51% or more passes a #4 sieve. If the results require a design change, construction of the system shall stop pending On-site review and approval of a change order. Please submit stamped and signed results of the percolation test, as well as the sieve analysis if required, with the inspection report/record drawings. / � w /� ? Received By: r4.— �iN Date: / Issued By: 6,tx.' av: c Date: cF/c5/7 0 I MunichaNty off Arachoraue u,p,1 �Lh.1�, P.O. Box 196650 G 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http:llwww.muni.orglOnsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW ** ** Waiver#: OSV171065 COSA#: Permit#: OSP171167 PID#: 016-102-14 Legal Description: Bruin Park Block 2 Lot 7 Engineer: Pannone Engineering Services Applicant: Travis & Heather Reier Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance is 10.0 feet. See engineer's waiver request and profile drawing for justifications. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. [] The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granted: Date: 0! 0/ 0 1 Approved by: Name of Reviewer **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE / ti". ) ---___i Community Development Department �: ,�/, Pho-� 0 -34 Development Services Division `'� • ' ' 4, On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION a 30\1 L 9 2.017I c. Parcel I.D. 016-102-14 it o 6 Q 9� Property owner(s) Travis & Heather Reier Day phone Mailing address 11026 Forest Park Drive, Anchorage, AK 99516 Site address 11026 Forest Park Drive Legal description (Sub'd., Block & Lot) Bruin Park, Block 2, Lot 7 Legal description (Township, Range & Section) Lot Size 41,600 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: lE all that apply) Absorption Field El Initial ❑ Single Family (SF) El (w/wo ADU) Septic Tank ❑x Upgrade ❑X Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Separation from slope Distance: 10.0 I certify that the above information is correct. I further certify that this is in accordance with applicable Munici•al Codes. 1 - (Signature of property owner or authorized agent) Permit/Rush Fees: Jr I— Waiver Fees: 915- Dateof Payment: {,!?JOIN Date of Payment: Ip1 30)17 Receipt Number: 05b'31 Receipt Number: DZ 145 t 6 Permit No. C(Den I1 Jo/ Waiver No. 05N/111066 Permit App_ - .:. .C: Pannone Engineering Services ac Steven R. Pannone, Principal Registered Professional Engineer E-mail:steve@panengak.com June 28, 2017 Subject: Bruin Park, Block 2, Lot 7 Septic System Permit Request Design Narrative This is a design narrative for a permit to install an upgrade septic system to be issued for this property. The proposed system will serve an existing five (5) bedroom house. Currently the lot is developed. The system will utilize a new 2000g S.T.E.P. tank. This lot and the surrounding lots are served by private wells. There are no wells within 100' of the proposed septic system. 1. Soils. One test holes was conducted in the area by Leroy C. Reid Jr. in 1989. Bedrock was not encountered in those test holes. Ground water was encountered at a depth of 10 feet in November of 1989. The test hole for the existing system on the subject property rated the soil at 150sf/br. An additional test hole will be performed at the time of construction. The upgrade design is based upon the original design absorption rate using 1 g/sf/d (150 sf/br) 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The existing topography on the lot generally slopes from east to west, with a slope of approximately 10% in the area of the drain field, and a slope of approximately 50% as close as 10' downslope of the proposed drain field. See waiver request. 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 Pannone Engineering Services iic Steven R. Pannone, Principal Registered Professional Engineer E-mail:steve@panenaak.com June 28, 2017 Municipality of Anchorage Development Services Department On-Site Water&Wastewater Program 4700 Elmore Road P. 0. Box 196650 Anchorage, Alaska 99519 Subject: Bruin Park, Block 2, Lot 7 Septic System to Steep Slope Waiver Request Ladies and Gentlemen: I am writing to request a separation distance waiver between the proposed septic system and a slope of greater than 25%to ten feet (10'). The soils in this area are typically Hydrologic Soils Group A which contains organics underlain by poorly graded sand (SP), as shown on the soils log. Due to the nature of and drainage capacity of the soils found in the area (HSG A) the designed infiltration line of 45% for septic system installation on steep slopes should be used instead of the assumed/worst case soil classification infiltration line of 25%. The slopes and soil types enable installation of any conventional system without the system effluent "daylighting" further down the slope of the hill provided bury depth requirements are met. Granting this waiver will not pose a threat to the safety of this lot or the surrounding lots. Mailing: P.O. Box 100217, Anchorage. AK 99510-0217 Physical: 332 East Manor Ave, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 Page 2 of 2 Please contact me if you have any comments or concerns. Sincerely, • I � 11 Steven R.P. none 4.4 136gS041 .1P4P Steven R. Pannone, P.E. Owner/Civil Engineer Attachments: -Site Plan Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor Ave, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 f CN< • N / 0 / ,POS" 11 1 06 �0 /� OPS • / / / / • LL �C / ' f r § W J \ U DECOMMISSION EXISTING TANK PER CODE AND INSTALL 2000g S.T.E.P. TANK / n. / INSTALL FOUNDATION CLEAN OUT SHED • GRADE BREAK/ TOP OF SLOPE-L ; TH-1 (P) SH LOT 7 • DRAIN FIELD (P) 1 GARAGE N (2EA) 51 LF x 5'W x 3.5'ED x 5'TD 1 70 WITH 1.25" PIPE WITH ,Ah ‘'% 12 ' Ya" HOLES DRILLED 30" O.C. ��. I� 6 . ` M ------..,,,:---- /. � INSTALL MT AT EACH END 4i ; // ` • ci, a' 1114 NI �4 ,;, • -4 5BR DRIVEWAY r/ , • rHOUSE 7/i ,•- 1; N10.0 \O (E) `2i) 101.7 t• /1.- - / TH-1 Alife / :6% LEE REID 1989 101.0 J<v r WELL (E) E. `" • 7i �O / WELL (E) • Qc , , N /• k • \�. �� N / ' RESERVE DRAIN FIELD V M-------- -----M REUSE EXISTING (BASED ON CAT III) s� 38LF x 5'W x 3.5'ED x 6'TD ' , / \42\ /\ DESIGN PARAMETERS PRIMARY SEPTIC SYSTEM NO. BEDROOM: 5 (750 gpd) LEGEND TANK SIZE: 2,000g S.T.E.P. W WATER LINE/ PERC RATE: <1 MPI WELL RADIUS ABBREVIATIONS SOIL RATING: 1 GPD/SF TH TEST HOLE AREA RQD: 750 SF SS NEW SEPTIC SYS. TYPE: WIDE TRENCH- 3.5'ED (P) PROPOSED RF:0.54 _ - _�B_ - — GRADE BREAK (E) EXISTING MIN LENGTH: 81 LF CO CLEAN OUT NO. USE: - 0 0 RETAINING WALL MT MONITOR TUBE NO. (2EA) 51LFx5'Wx3.5' E.D., 5.0' TD TYP TYPICAL TOTAL AREA: 944 SF NOTES: >>>����\v Dote PANNONE ENG SVC, LLC of A� �1 8�4�2017 FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 ..-�� qs ll PHONE (907) 272-8218 FAX (907) 272-8211 "ea,:' �� 1;7I scale DRAWN BY: If*; •• 1- • * 1"=50' DRM rild •.,410���,. \. - I.D. NO BRUIN PARK, BLOCK 2, LOT 7 / 016-112-14 - TRAVIS & HEATHER REIER 'teven'F�. F'onnorae PERMIT NO. 0 -v•, CE 8149 e Ai — 11026 FOREST DRIVE #+ rJ. ., • '�. 0SP171167 PLAN ANCHORAGE, AK 99516 ll T404; ••. 1 f SheetOF 3 A\vV%- DRAIN FIELD DRAIN FIELD EXISTING GRADE 10% - - 2.5 _._ 3.5 50.0 SECTION NOTES: PANNONE ENG SVC, LLC cf.A�`gs�1 8%4/2017 FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 r PHONE (907) 272-8218 FAX (907) 272-8211 ecb.• �i� 91To Scale DRAWN BY: ;or: • *.'49 1. /\ *1, NTS / ...'��� .. =. .D. NO DRM BRUIN PARK, BLOCK 2, LOT 7 �, W / 016-102-14 TRAVIS & HEATHER REIER -- Steven R. Pannone' PERMIT NO. CE 8149 4 J OSP171167 11026 FOREST DRIVE fe cs . � DESIGN DETAILS ANCHORAGE, AK 99516 4k .iEp•• '*... Sheet `` N\\NO■-t 2 OF 3 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55. 2. SCOPE OF WORK: INSTALL NEW TANK AND DRAIN FIELD. 3. GROUNDWATER WAS ENCOUNTERED AT A DEPTH OF 10.0 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 10.0 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 4. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 5. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 6. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 7. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 8. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 9. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED-LINE AS-BUILT DRAWINGS TO THE ENGINEER. THE RED-LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. 10. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN-OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 11. THE CONTRACTOR PROVIDED DATA (UPON WHICH THIS RECORD DRAWING IS BASED) APPEARS TO REPRESENT THE PROJECT AS CONSTRUCTED. THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR. 12. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE AS-BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. CONTRACTOR: BY: , TITLE: • DATE: DESIGN PARAMETERS RESERVE SEPTIC SYSTEM NO. BEDROOM: 5 (750 gpd) TANK SIZE: 2,500g ADVANTEX W/ 2 AX20 PODS AND AUX PUMP VAULT PERC RATE: <1 MPI SOIL RATING: 6 GPD/SF AREA ROD: 125 SF SYS. TYPE: WIDE TRENCH- 3.5'ED RF:0.54 MIN LENGTH: 13.5 LF USE: EXISTING 38LFx5'Wx3.5' E.D., 6,0' TD TOTAL AREA: 352 SF NOTES: PANNONE ENG SVC LLC _—„oz.-x.1% Date OF AL l 8/4/201 7 FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 P'��'' 'QS PHONE (907) 272-8218 FAX (907) 272-8211RAGE, 49% DRAWN BY: pi' *' I ."� * NTS BRUIN PARK, BLOCK 2, LOT 7 . • +2-14 TRAVIS & HEATHER REIER t'te en f . 'ann•pe PERMIT NO. CE 8149 •ck- 0SP171167 11026 FOREST DRIVE r • DESIGN DETAILS ANCHORAGE, AK 99516 +�k�`o�iPo►TSs�o�'� Sheet 3 \��� MUNICIPALITY OF ANCHORAGE ~)1~--/~)~'-//7 DEPARTMENT OF HEALTH AND HUMAN SERVICES Environmental Health Division 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Name , DISTANCES Z:~5'/?'~ '~' /'f//,~.r,¢14~J,..., ~¢~e~ ~ SEPTIC ABSORPTION WELL Addres~ ~ TANK FIELD ~ - 2~ ~ ~ r ~ WELL LEGAL OESCRIPTION LOT LINE  I Subdivision ,cDt ~ e,o~k ~ I ~ ~ FOUNDATION ~'~ ~ ~.~ Township, Range, S~tion ~ / ~ ~ ~ ;'~O/ ~ ~, / ~/~ --/~ --/~ driveway,AS'BUILT DIAGRAM (Show location of well, septic system, prope~y lines, foundatiOn,water bodies, etc,) TANKS Manufacturer Capacity in gallons ~ Material No. of Compa~ments ~ TYPE OF SYSTEM ~ ~ TRENCH ~ BED ~ W. DRAIN ~ OTHER ~ ~ Depth to pipe bottom from Total depth from original grade or~ai.a, ar~de ~,3~ FT ~ FT Gravel depth beneath pipe Fill adde~ above origi~ai grade ~'~ ~ FT ~,~ FT Gravel length ~ /FT Gravel width ~/ FT Total absorption area Distance between lines ~ so ~T ~/~ FT Number of lines Soil rating Pipe material ~ ~ Date Installed Installer . ~/~ ~ ~ , ,, WELLS ~ PRIVATE ~ OTHER (Identilv) oassification (A,e,C) Tota~ Depth ~ Cased to ~,~ /~ / ~TI /~ / FT '~ ~'~ ~.. . ..~,' ~/d,.~ ~;,//. ~ ;-/~-;? REMARKS: ~ale: ~ ~ ~ ENGINEER'S SEAL ~.~ ~ ~a/~ ~a= ~ ~..~/~. ,.s,ec,o~s~e~orme~: ,- ,. I ~ ~ /~e ¢ ~ ~'//e d cedily that this inspe~ion was pedormed according to all Municipal and State guidelines in effect on this date: ~f~ ~ ~/~ ' Health Depadmenl Approval: _ ~ ~ . Date: 72-013 (3/85)  ALASKA E[1UIRO[lmEI1TAL CONTROL $ERUICE$, IFIC. o I~nqince~'in§ ~ Enuironmenlal Studies 1200 LUest 33rd Auenue. Suite [~. Anchoraq¢. Alosko 99503.[907) 561-5040 TO ~A~. S U B J E CT ,....~.~,,,~.,,-..Z..,...,...,.~'~r/,~l,:.:..~ ...................................................................................................................................................... //~,~,.~, ~...~:.~,~.~ ................................. MUNICIPALITY OF ANCHORAGE D ~t~?,. ,. OF,....HE~L:[:H & ENVIRONMENTAL PROTECTION INSPECTION REPORT MUNICIPALITY OF ANCHORAGE,3500 EAST TUDOR BUILDING ROAD SAFETY DIVISION NSPECTIONS (907) 563-3464 INFORMATION (907) 786-821 FOOTING [] ELEC. TEMP. FOUNDATION [] ELEC. SERVICE 0-;:- BOND BEAM [] ELEC. ROUGH FRAMING [] ELEC. FINAL INSULATION - [] OTHER SHEETROCK [] STRUCT. FINAL [] FIRE FINAL OTHER [] ZONING [] PLBG. UNDGR. [] [] PLBG. ROUGH [] "~ GAS TEMP. [] [] GAS [] [] MECHANICAL [] MECH. FINAL [] [] PLBG. FINAL [] [] OTHER [] [] NO NONCOMPLIANCE OBSERVED [] WILL REEXAMINE AT NEXT INSPECTION [] CORRECTIONS ESSENTIAL AS EXPLAINED BELOW [] DO NOT CONCEAL UNTIL REINSPECTED INSPECTOR DATE WHEN CORRECTIONS ARE MADE, PLEASE CALL FOR INSPECTION ~ DO NOT REMOVE THIS NOTICE 84-002 [Rev,~l 1/87) :Dliii:~J :1; A'T :[ EIN l:::'l::~[::)l"t ¢~F:'I;::I::~:E)VIE)',:) 1:::'1::;: :~: Cfi:;; "I"C! CE]f",IEi'T'I::;..'UCT' V¢~'T']:[31q::ii~ klU~ilYl" ]:fie C)I::'ENIE:[:)/C:L,,E)St:ii:):.~ N]:C']H'T', "t"H:t:~ii~ F:'E:I::;:I"f]:T' I:;:' ]: ~:;i:l."!!:t!!i; Ot",1 :1. 2/::!!; :I. P~I",':h'.':~lql:)C)lxll!!i::[:), ¢":~ 1,,., :1: I:::'1" '°,/ ALASKA 6FIUIROFImI FITAL CORTROL $ERUICI $, IRC. .,~ I~nclincerinq ~, I~nuironm~nlal Studies SPECIFICATIONS FOR A FIVE-WIDE WASTEWATER TREATMENT SYSTEM LEGAL DESCRIPTION: LOT 7, BLOCK 2, BRUIN PARK SUBDIVISION. 1.0 GENERAL 1.1 The Drawings, sheets 1 thru 5, shall be a part of this specification. 1.2 All materials and workmanship shall meet the requirements of the Municipality of Anchorage, Department of Health & Human Services (DHHS), the conditions of the permit, and all applicable rules and regulations currently in effect. 1.3 All elevations and depths are advisory and are to be verified or modified in the field by a DHHS approved inspector. 1.4 It is the responsibility of the property owner or installer to adhere to approved designs for installation, maintain the specified separation distances, and have the appropriate inspections. 1.5 It is the responsibility of the property owner or installer to report to the engineer any observed conditions which would put the system in violation of state or Municipal regulations. 1.6 If the installation is not inspected by an AECS engineer, AECS will not be responsible for the installed system. An engineer at AECS should be consulted prior to construction, to determine the number of inspections that will be required and to explain what these inspections will involve. 2.0 SEPTIC SYSTEM 2.1 The existing septic tank may be used, if it meets the capacity requirements for the residence and the approval of DHHS. Older systems may need tank integrity verified. If not, then specifications 2.2 through 2.6 apply. 2.2 The septic tank shall be a UPC-approved two-compartment tank, constructed of 12 gauge steel with bitumastic coating, set level on undisturbed soil and insulated with overlying layer of 2 inch burial type polystyrene. 2.3 The septic tank shall be a minimum of 5 feet from 1412 We, St 33Rb c~v6nu6 · ,kncho~ac~6, Alaska 99503 · (907) 279-5553 2.4 2.,5 2.6 2.7 the house foundation, and a minimum of 5 feet from the absorption area. The septic tank and drainfield shall be a minimum of 100 feet from any private well or body of water, 150 feet from Class "C" wells, and 200 feet from Class "A" or "B" wells, unless otherwise specified. Less than the required separation distance must have prior approval or waiver by Alaska Department of Environmental Conservation (ADEC). Piping shall be fitted with a mechanical watertight calder coupling of the inlet and outlet of the septic tank. Piping shall be 4 inch ASTM D-3054 or cast iron, sloped a minimum of 1/4 inch per foot from the house to the tank and 1/8 inch per foot from the tank to the trench. Cleanouts shall be installed as designated, capped with air-tight rain caps (Jim Caps or equivalent), and extend a minimum of 2 feet above ground level. If a lift station is required, it shall be a combination lift station septic tank per Anchorage Tank and Welding, Inc. design. Specifications and design drawings are on file with the Municipality and the engineer, 3.0 DRAINFIELD 3.1 The gravel for the drainfield shall be 0.5 to 2.5 inch, screened rock with less than 3 percent passing the No. 200 sieve. All substitutes must have prior DHHS approval. 3.2 The bottom and side of the excavation shall be raked with the backhoe blade to ensure that it has not been compacted during excavation. The bottom elevation shall be level. 3.3 Monitor standpipes(s) shall be placed as shown in the drawings, and shall be rigid PVC ASTM D-8034, or 4 inch cast iron. The section shown with holes may be drilled 0.5 inch holes on the 6 inch centers on opposite sides of the pipe, or a regular section of perforated sewer pipe, clamped to a solid section, with either a no-hub coupling or a solvent joint. The perforated section of the monitor tube shall be located in gravel only. A 3.4 3.5 3.6 3.7 rubber rain cap (Jim Cap or equivalent) shall be placed over the top of the pipe. The distribution pipe shall be 4 inch rigid PVC with a minimum crush strength of 1500 pounds or equal. All distribution pipes shall be laid level. If the final grade of the drainfield is less than 4 feet from the gravel, insulation is required using burial type polystyrene rigid board insulation. There shall be 1 inch of insulation for every foot of soil less than the required 4 feet of cover, but there must be at least 18 inches of soil cover even though insulation is used. The solid pipe extending from the septic tank or lift station to the drainfield shall also have a minimum of 4 feet of cover or an equivalent layer of insulation to prevent freezing of the line. Filter fabric is required on top of rock. It is recommended that the area excavated and the area in the vicinity of the drainfield shall be planted with a white clover, red rescue mix, or with Kentucky bluegrass. 4.0 INSPECTIONS 4.1 A minimum of three inspections are required for installation of the trench. The first inspection will be of the excavation to verify that the installation will be in the proper soil. 4.2 The second inspection will be after placement of the gravel, monitor standpipe(s) and distribution pipe to verify proper installation before backfill. 4.3 The third inspection will be after final backfill, grading and seeding to ensure that adequate soil cover has been proved over the drainfield. 4.4 The inspection of the septic tank can be incorporated with any one of the above listed inspections. 4.5 The lift station will require either an MOA electrical inspection or certification by a licensed electrician depending on whether the building code applies to this part of the city. ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. JOB SHEET NO CALCULATEO,V /, CHECKED BY DATE SCALE PRODUCT 21)4-1 ~ Inc., Groton, Mas~. 01471 0 Z Iii J H X o Z · LI hi n ri H c o 0 L 0 C $ .J J H 0 > o Z 0 mo .0 fl' ZU ~ 0~ "~ >~; <OZ m z gram Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES ,, SOILS LOG -- PERCOLATION TEST PERFORMED FOR: ~/~ LEGAL DESCRIPTION: 1 2 3 4 5 WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT / ~) DEPTH? /'~ p E, SLOPE SITE PLAN Depth to Water Alter/~,, /,8/~o/1~'~, Monitoring? Date: 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE __ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FT AND FT COMMENTS PERFORMED ACCORDANCE WITH ALL STATE'AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. 72-008 (Rev, 4/85) CERTIFY THAT THIS TEST WAS PERFORMED IN DATE: /~-/'/~'? ALASKA ENVIRONMENTAL' CONTROL SERVICES, INC. !200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 561-5040 JOB SHEET NO. CALCULATED BY o~ .4- DATE REID, JR~ i'¢E~2251 4¢'*" Me ~o poe ./ ,N 9'. EAS~,M~NTS OF RECORD, 'OTHER THAN THOSE SHOWN O~ THE RECORDED PLAT ARE NOT SHOWN HEREON. The-information hereon 'is for the use of lending institut'ions.-showing-the ,relationship of existing* structures and platted easements and lot lines. It is not to be used for positioning additional'' structures or fencelines. DRAWN: DMS" IFB ] 6RID: 10-20-89 :. ~ .......... [ .,DATE .... SCALE: : . : 1"=30! 9-53 2633 · AS-BUILT/No oorners set this date I hereby certify that l' have performed a ~;ortagec'~ ~- spe.ction of the lollowEng described property: Bruin Park Subd..,L,ot 7,Blk. 2 ,,. Ancho~rage }l~cording ~ecinct, Alaska, and that the men~ ~ituat~ th~aon ~e wi~ the pro~2 ~ne~ and do "'not'overlap or'end.ch on the pro~ty lying adjacent ~er~ ~, that no ~p~vemen~ on pro~ lying adjacent ~ereto e~t~oach on the pre~as ~ question ~d that ~ are roadway,, W~sm~ion lines or other visible e~man~ on said ~roperty except ~ lndica~d Dated at ~orage, ~uka · ~j~ 2Q, day of, Oct. ,, 1989 ~ 688.4565 t MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION RECEIVED ,N EASEMEN"i'8 OF RECORD, 'OTHER THAN THOSE SHOWN.O~ THE RECORDED PLAT ARE NOT SHOWN HEREON. The~-information hereon 'is for the use of lending instit~'i'Ons-sho~ing-the .relationship of existing' structures and platted easments and lot lines. It is not to be used for positioning additional structure~ or fencelines. DRAWN:_ '.. DMS ,' SCALE: . " ' 10-20-89 FB: ' ' ' !"=30', , 9-53 2633 - AS-BUILT"No' oorners ,se~ ~his date hereby certify that 1' have par/ormed a ~orlagee'~ spectlon 0% the following described property: , ~ Bruin Park Subd. ,Lp.t ~,Blk.... 2 Anchorage P~cording Precinct, Alaska, and that the improve- masts situated thereon are within the pro~ert¥ lines and do 'not'overlap or'encroach on the property lying adjacent there~ to, that,no im. provements on property lying adjacent thereto encroach on t~e premises in question and that there are no roadways, ~ansmi~s/on lines or other visible ea.~ment~ on said property except as indicated he.i-eon~ Dated at Anchorage, A~ask& . m!: 20 da3, or.,, Oct. · . - 688-4566 .SEWA.RI.).&.. A...SS.OCIATES LAND SURVEYING WATER WELL RECORD STATE OF ALASKA DEPARTMENT OF NATURAL RESOURES Division of ISeologicol 8~ Geophysicel Surveys Drilling Permit No. LOCATION OF WELL (Please complete either ia, lb or lc.) A.D.L. No. ~a~.lBorough Subdivision Lot Block I-'~.I '/4qlrs. Secfion No. TownshiPN0 Range E['-J Meridian ~.,~,,~ 7 "Z- _o,_o,_of_ sn wn  DISTANCE ~ND ~' '~ ROAD INTERSECTIONS ~. OWNER OF WELL: DIRECTION FROM ,, Address'. ~ ~.-~-~4: .~ ,,1 ~c~. Feet Below 4. WELL DEPTH: (final) 5. DITE~F CO~PLETIO~ Material Type Top Bottom ·- '' '~ ' ' ~ ~,,,. ~ ,~. ,al'd/,,. o.,,~ w.,~,, 17 ,~,.I,,. , diem. in. to__ fl. Depth Stlckup . 9. FINISH OF WELL:~. Type: ~ /- - Dlomefer: ~ Slot/M Size: Length ..'~ .~- Set between ft. and ft. .~ Backfillin~ Gr~vel pock " / t'i / ~ . .~,' I0. STATIC WATER LEVEL: .~'~_ '~ ........... /'~ ~ AbOve or ~:Below land surface Dote ~, ,~,::, /~ ' fl. ,flor hrs. pumping~g.p.m.  Materiel: ~ Neat Oenent ~ Other: 't, I~.PUMP: (If available) HP Length of Drop Pipe ft. ~apacily g.p.m. 14. REMARKS: 16. WATER WELL CONTRACTOR'S CERTIFICATION: 15. Water Temperature ~o ~ F ~ C This well was drilled ~r ~sdlction and this ~eport is true fo the~est of my knowledge and belief; /r~i~F~r~'a Busi.~s No~ ' ' Conlract' Licen~ Number ~,,,,,~ ~, Z~.~ //~2/~ ,~..~~ /~'~>~'~. -,': //' m...... ~ dt ~ori'z~d ~present, five Form O~-WWR (Il/81) C~y~isiri~tio~.;'"WHl~E~ -~t~fe ~6~S, PINK-Driller, CANAEY-CusIomer MUNICIPALITY Of ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Sita Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 (907) 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILLY DWELLING Parcel I.D. # 016-102-14 HAA # ,,~/'q ( i(' ?(2:'/ I ~ 1. GENERAL INFORMATION Complete legal description BRUIN PARK SUBDIVISION: LOT 7. BLOCK 2. Location (site address or directions) 11026 FOREST DRIVE Property owner Mailing address Lending agency Mailing address LARRY DONAHUE Dayphone 244-5568./5447-5150 11026 FOREST DRIVE ANCHORAGE. ALASKA 99516 Day phone Agent TAMMY KELLY w./ REMAX PROPERTIES Address 2600 CORDOVA STREET ANCHORAGE. ALASKA Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: 2 TYPE OF WATER SUPPLY: Individual well xx Community well Public water Day phone (907~ 276-2761 99505 NOTE: ff community well system, provide written confirmation from State ADEC attest- lng to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding Tank Community on-site Public sewer XX NOTE: If community wastewater system, provide written confirmation from State ADEC lng to the legality and status of system. 72-025 {Rev, 1/91 } Front MOA #21 Computer Version 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verity that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wast°water disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of investi ation and insp,~ction, the on-s te water supply and/or wast°water Anchors efi es and from my g ' ulat OhS n effect d sposalg~ystem is in comp ance with all Munici ,P, al/and State codes, ordinances, and reg on the date of this inspection. , /-7/ [ ^, o~,^ ,^,A'~ ~/~S/T~'~/~ITER CONSULTANTS, INC.. Phone_ (907) Name of Firm **~-,o, ............ Address 0901 DEBAReROA.D/, ~'~L'T/E 2//¢/ANCHORAGE, ALASKA 99504 .= 3/~o Engineer's Signature-( .... ~,,iY~- ~=' .O,~- In conducting this .valuation. AWWC. ,n/,tfJmpt(~J to provids a th°r°Ugh' consden#ous eegtheedng ~aiysis of fhe system in accordance wffh ADEC and MOA DHHS Guidelthss & Regulations, The repotted ~:=',~ "~. ,', ? ' "dtI. tI. tI. 4, ·. a~dsspt~ssystsrnsdepond~nth~lcca~s~tIsc~dtIi~n~r~und~t~w~$th~t~n.~y#uct~at°~sdngthe ~....," .,.. ~ . . .:....~ guaranis° future performance o! tbs system, no~' do lbeY gusranisa thst there are ~o hidden de~ect~ or ,'" encro~chrnsnts. AVVWO, tho. can lhere~ore ~o~ provide a~y wauanty Cot future performance nor giro any ~t~._ ' tfr~ A. G~rn ess.: sstImat~ ~ h~w ~ng ~h~ syst~rn ~ c~ntin~ ~ meet ~h~ °poratI~ns~ regulrerne~t~ ~f th~ A~ ~r M~A ~ ~ ,~-7955 OHHS, The cent°hi of this report Is rot th~ sole bene§t o! ths re'met listed ~bove, Any retis~ce upon et ss° ~Hh~ r~port by a~y ~h~r pors~n ~r Par~y ~s n~t au~;h~ri~ed~ n~r wi~ ~t c~n~r a~ ~ega~ r~gh~ wha~w~. ' · ' ' 2. Alaska Wa ter a.d Wast°water Cot~sultants. thc, shall be pold $1.165.00 at, or pdor to, closing for the ~:~e~ engineering sap/Ices provided. 6, DHHS SIGNATURE L.--'/ Approved for_ ~'- . bedrooms Disapproved Conditional approval for bedrooms, with the following stipulations: Additional Comments. The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72K)25 (Rev. 1/91 ) Back MOA g21 Computer Version Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVIC~R Environmen~i Se~i~s Division 825 "L" Street, Rm 502 ~chomge, Alaska 99501 (907) Health Authority Approval Checklist Legal Description: BRUIN PARK SUBDIVISION; LOT 7, BLOCK 2 Parcel I.D.: A. WELL DATA Well Type PRIVATE Log present (Y/N) Total depth Sanitary seal (Y/N) Date of test 141' IfA, B, or C, attach ADEC letter. ADEC water system number Y Date completed Cased to 141' YES FROM WELL LOG 12/lO/B9 12-10-89 Casing height (above ground) Wires properly protected (Y/N) AT INSPECTION 5/15/2000 57' 42' 17" YES 016-102.14 Static water level Well production 40 g.p.m. 6.5+ g.p~m. , .~'~ %c~/~. Other bacteria ~ Collected by: A.W.W.C., INC. Number of Compartments 2 Cleanouts (Y/N). YES NO High water alarm (Y/N) N/A WATER SAMPLE RESULTS: Coliform ~ Nitrate Date of sample: ~ c~ _[(~ B. SEPTIC/HOLDING TANK DATA Date installed 12/8/89 Tank size 1250 Foundation cleanout (Y/N) YES (iN BASEMENT) Depression (Y/N) Pumper. A+ HOME SERVICES Soil rating (g.p.d./fl2 or ff2/bdrm) 150 5' Gravel thickness below pipe 3.5' Total depth Date of Pumping 5/15/2000 C. ABSORPTION FIELD DATA Date installed 12/8/89 Length 58' Width Effective absorption area 552 SO.FT. Date of adequacy test 5/15/2000 Fluid depth in absorption field before test (in.); Fluid depth 31.5 (ins) Minutes later: Peroxide treatment (past 12 months) (Y/N) 72-026 (Rev. 3/96)* Computer Version Monitoring Tube present (Y/N) YES Depression overfield (Y/N) Results (Pass/Fail) PASS For 28.5 Immediately after 461 173 Absorption rate = NONE KNowN If yes, give date System type SHALLOW TRENCH 6' NO 2 Bedrooms gal. water added (in.): 58.25 ,300+ C.P.D. D. LIFT STATION Date installed 12/8/89 Manhole/Access (Y/N) YES High water alarm level at*. 45" Cycles tested ;5 Size in gallons 1250 "Pump on" level at* 43" ."Pump off" level at* *Datum BOTTOM OF TANK 39" E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot Public sewer main Sewer/septic service line 100'+ 100'+ N/A 25'+ On adjacent lots. 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Lift station N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation. 5' + Property line 5' + Water main/service line 10'+ Surface water/drainage. 100'+ SEPARATION DISTANCES FROM ABSORPTION FIELD ON LOT TO: *8' Building foundation 100' + 10'+ NONE KNOWN Property line Surface water Curtain drain Absorption field. Wells on adjacent lots 5'+ F. ENGINEER'S CERTIF I certify that l/f~d~l of Municip§[ recor~s/i with MOA ~AA g~ic/~ Signature Engineer's Nam/e Date 100'+ *SEE AFFACHED WAIVER REQUEST. .Water main/service line 10'+ Driveway, parking/vehicle storage area Wetls on adjacent lots 100'- field Inspections and review systems are In conformance )n this date. JEFFREY A. GARNESS >g 10'+ '4--~ ~) ¢ ,, Waiver Fee $ HA,& Fee $ Date of Payment (-~> '-- ~-?/~-- E:~ C) Date of Payment Receipt Number ¢2'~¢z7 ~'k~(/~l/? "~,,~ , Receipt Number 72-026 (Rev. 3/96)* Computer Vemlon AK Water & Wastewater Consultants, Inc. ATTN: Jeffrey Garness, PE 6901 De Barr Road, Suite 2B Anchorage, AK 99504- March 31, 2000 Subject: Waiver Request forBRUIN PARK BLK 2 LT 7 Waiver # WR000015 Lot Line Request for Parcel ID 016-102-14 Dear Engineer: Your request for a waiver of the required 10 feet horizontal separation of the on-site wastewater disposal system to the lot line has been approved. The approved separation distance is 8 feet. This waiver approval applies to the current on-site wastewater disposal system and lot line separation only. Any future upgrade to the on-site wastewater disposal system and lot line will require all separation distances to be met or another waiver approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-4744. Sincerely, jeffPoet~ ~a'~'7~ Engineering Technician III On-Site Water Quality Program MUNICIPALITY OF ANCHORAGE Department of Health & Human Services On-Site Services Waiver Review Worksheet WR#000015 PID# 016-102-14 HA#: HA000113 Permit~ Date Received: Mamh 24, 2000 Legal Description: Bruin Park Subdivision, Lot 7, Block 2 Engineer: Alaska Water & Wastewater Consultants 6901 Debarr Road, Suite 2-B, Anchorage, AK 99503 Applicant: ~.F~,~ /'~E)~'/'?~ .......... Waiver Requested: Property line wiaver on the subject property for the separation distance between the leachfield and the southwest property line at 8 feet. Criteria: 1. Geology A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation 2. Special Conditions: 3. Other: Points: Total: WaiverisGranted: ~ List Conditions or Reasonsfor above: Waiver is not Granted: Date: ~-3)'~o l~j~e of Reviewer Rec.~: 05795 Amount: $115.00 Date Paid: March 24, 2000 ALASKA WATER & WASTEWATER October 21, 1999 Municipality of Anchorage Department of Health & Human Services On-Site Services Section P.O. Box 196650 · Anchorage, Alaska 99519-6650 Subject: Lot Line Waiver for Lot 7 Block 2; Brain Park S/D To whom it may concern: Request you issue a property line waiver on the subject property for the separation distance between the leachfield and the southwest property line at eight (8) feet. Enclosed is a copy of a recent asbuilt survey by Shane Holt, Land Surveyor. The clean-out at the end of the leachfield is located approximately 8 feet from the southwest property line. We measured the distance between this cleanout and the neighhoring well (Lot 8; Blk 2). It meets the 100 fi separation distance requirement. We do not anticipate any adverse effects by issuance of this waiver. If you have any questio~ Sincerely, ~ , please contact us at 337-6179, or 244-9612. JAG/gd 6901 Debarr Road, Suite 2-B * Anchorage, Alaska 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * email: awws~alaska.net 03/21/2000 18:52 9072589701 TAMERA KELLY PAGE 82 8 38°03'00"W 160.00' N 38~03'00"E 160.00' MUNICIPALITY OF ANCHORAGE ~ ' Department of Health & Human Services DIVISION OF ENVIRONMENTAL SERVICES 343-4744 Parcel I.D. # CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF' ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING 1. GENERAL INFORMATION (Must be completed prior to submittal) (a) Legal Description (include lOt, block, subdivision, section, township, range) (b) Prop~pwner ~ d~ ~ Telephone : (home) Mailin~es~)~~ ~ o~/~ ~'~'"*"*"~"' - '" Tele hone (c) Lending I~stitution '..~ ' P Business Mailing Address (d) Real Estate Company and Agent Address Telephone (e) Mail the HAA to the following address: (or check hereJZ, if hold for pick up.) List contact person and day phone number below: TYPE OF RESIDENCE Single-Family,S.. Number of bedrooms WATER SUPPLY Individual Well)~ Community [] Public [] Note: If community well system, must have written confirmation from the State DePartment of Environmental Conservation attesting to th legality and status. SEWAGE DISPOSAL On-site,S[. Public [] Community [] Holding Tank Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legailty and status. 72-025 (Rev. 7/88) Page 1 of 2 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional .and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance witl~ all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Address Date Telephone 03. ~ ~'--.J-'Y-J'"J~ 6. DHHS APPROVAL Approved for // bedrooms by Conditional The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval cerificated based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DH HS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 7/88) Back Page 2 of 2 MUNICIPALITY OF ANCHORAGE (MOA) H.ealth~ Au~'~'0HtY Approval (HAA) ~":~ :if~,",, .CHECK,~t~~. ~FEi~RUARY 1984 ...... = 343-4744 A. WELL DATA Well Classification Well Log Present CH) Total Depth/~ / ~ Cased to /~/ Static Water Level -.~;~ Casing Height Above Ground /~,~ Electrical Wiring in Conduit(~,,~) SEPARATION DISTANCES FROM WELL: To Septic/Holding Tank on Lot To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line To Nearest Sewer Service Line on Lot Water Sample Collected by ~' Water Sample Test Results ~c'/'.' Comments Legal Description: __ Date Completed _ Depth of Grouting //',~ · Pump Set At ~',,/:,,o~ ~ . Sanitary Seal on Casing ~N) Depression Around Wellhead (Y/~ If A, B, C, D.E.C. Approved (Y/N) Yield /'~)'~'/ /'~ ~'' ; On Adjoining Lots /OZ- / ; On Adjoining Lots /~d ¢ ' To Nearest Public Sewer Cleanout/Manhole ; Date /2-/x ~-/~' ?' B. SEPTIC/HOLDING TANK DATA Date Installed /~/~,~/~'~,,' Size Standpipes~)'N) Depression over Tank (Y/~ /,2.¢-o No. of Compartments Air-tight Caps~)N) Foundation Cleanout (Y/(~ Date Last Pumped Pumping/Maintenance Ool~tadt.'Dn ,~jle (Y/N) ~J/,~. ; for X J/,4 Holding Tank H~g~-Wate'f.AJarm (.~),~_ ~/4 Temporary Holding Tank Permit (Y/N) SEPARATION D~.STA. R c~S:F~u-~ r~ ~.E~HOLDi NG TANK: To Water Su Well /~/ To Bu~l - p~y ..... ~ d~ng Foundation To Property Li~~ ~ To Disposal Field ~ / To Water Main/Su~e~Lin~ ~ ~' To Stream, Pond, Lake or Major Drainage Course ~/o~ / Comments 72-026 (Rev, 7/88) Front Page 1 of 2 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field Square Feet of Absortion Area Depression over Field (Y~) Type of System Design Length of Field ~'¢ / Depth of Field ¢' ~' Gravel Bed Thickness 3 5- ' Statndpipes Present ~N) Date of Last Adequacy Test Results of Last Adequacy Test SEPARATION DISTANCE FROM ABSORPTION FIELD: To Water-Supply Well /0~/ To Building Foundation Lot /~ / To Water Main/Service Line ,~. To Stream, Pond, Lake, or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area To Property Line To Existing or Abandoned System on ; On Adjoining Lots -~ ¢ / To Cutback (if present) Comments D. LIFT STATION ._.~_,~ _~'e.~¢7c Date Installed {~-/7'js'?' Dimensions 5 22 Size in Gallons ~[~/'~5~ ~,& 7~ Manhole/Access~) "Pump On" Level at ~~/~ ~4 h~t "Pump Off" Level at ,, High Water Alarm Level at ~t¢~¢'~ ~ ~ Vent ~N) Tested for ~ Pumping Cycles during Adequacy Test. Meets MOA Electrical Codes ~) ~ ~ ~ Comments **Check Permitted Bedroom Rating Against HAA Request** I certify that I have checked, verified, or conformed to all MOA and H inspection. ~ Signed ~~'"'"~ Company Date / 2-/~-~//~' ? MOA NO. ~ -'~'~-~/ Receipt No. Date of Payment Amount: $ ,~&~u~[ir~,~i~,~a~fect on the date of this ~ ~~ t Engineer's Seal Receipt No. Waiver Fee: $ Date of Payment 72-026 (Rev. 7/88) Back Page 2 of 2