Well Owner.
M-W DRILLING, Inc.
P.O. Box 110378 · 10330 Old Seward Highway
(907) 349-8535
ANCHORAGE, At. ASKA 99511
GILBERT BREWINGTON
DRILt, ING LOG
_Use of Well DOMESTIC
Location (address of: Township, Range, Section, if known; m' distance main road
TRACT D-1, BREWINGTON S/D
EKLUTNAr ALASKA
Size of casing. 6" Depth of Hole~202 feet Cased to 45 feet
Static water level 80.70 ft. l~b)~!~) ibelow) land surface. Finish of well (checkone)
Screen ( ); Perforated ( . ).
Describe screen or perforation N/A
Well pumping test at 1 . 5 gallons pe~ (~) (minute) for 1
of drawdown from static level. AS BUILT NOTES: 1 )
Date ofcompletioL05 OCTOBER 1998
open end ( X );
hours with 100%
WELL DRY GROUTED WITH 2
SACKS OF BENTONITE GRANULES
Depth in feetfrom
ground surface
WELL LOG
Give details of formations penetrated, size of material, color and hardness
0 TO 2 cASING STICK UP
2 TO. 5 GRAVEL: BROWN, SILTY
CO,BBLES
RAVEL
GRAVEL: SI:LTY
BEDROCK: LIGHT GREY SILTSONE~'~RGILLITE
AS'ABOVE: BLACK GREY; WATE~'SEA~,IN SPORADIC FRACTURES
5 .TO 12
12 TO. 20
20 TO. 41.
41 TO 69
69 TO 202
TO
TO
,TO
TO.
, oRECEIVED
.TO AUG 2_0 1999
~Mpnicipality of Anchorage
D'Sp'~, Heaifi, &fl-luman Services
~A Certified Contractor
Certificate No's. ,~i4 ~ 573
1- CUSTOMER
MUNICIPALITY OF ANCHORAGE
Department of Health and Haman Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(9O7) 343-4744
ON-SITE WATER SUPPLY PERMIT
Initial
Permit Number: SW980392
Legal Description: ¢,'~ E ~ / 4,'¢¢ ~Fo ~v' / T,~/~ c 7
Design Engineer: 0000 None Required
Owner Name: Gilbert & Dorothy Bmwington
Owner Address: PO BOX 877541
Wasilla, AK 99687-7541
Date Issued: Oct 02, 1998
Expiration Date: Oct 02, 1999
ParcelID: 057-121-04
Total Bedrooms: 2
Site Address:
Lot Size: 872507 SQ. FT.
Permit Bedrooms: 2
This permit is for the construction of:
~ Disposal Field [] SepticTank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 (24 hours ). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By.
Date:
Rick Mystrom,
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6850
343-4744
August 18, 1997
Gilbert L & Dorothy V Brewington
PO Box 877541
Wasilla, Alaska 99687 7541
Subject: Tract D-1 Brewington (formerly Tract D Brewington)
Permit #SW960253, PID #057-121-05 (formerly 051-121-04)
The subject permit, issued August 15, 1996 by this office for a
single family well and/or on-site wastewater system, has
expired as of August 15, 1997.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. Ail inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
/a~me~srely' ~ Cross, P
Mrogram Manager
On-site Services
anc: Copy of Permit
cc: Eagle River Engineering Services
PAGE
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NLTMBER:SW960253
DESIGN ENGINEER:EAGLE RIVER ENGINEERING SERVICES
OWNER NAME:BREWINGTON GILBERT L &
OWNER ADDRESS:P.O. BOX 877541
WASILLA, ALASKA 99687
DATE ISSUED: 8/15/96
EXPIRATION DATE:
PARCEL ID:05712104
LEGAL DESCRIPTION:
BREWINGTON TR D
LOT SIZE: 872507 (SQ. FT.)
NUMBER OF BEDROOMS: 2 THIS PERMIT:
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80) .
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
1 OF
8/15/97
SPECIAL PROVISIONS
RECEIVED BY: ~
ISSUED BY:. /*--~.~~
Eagle River Engineering Services
Louis Butera, P.E.
P.O. Box 773294 (907) 694-5195 tel
Eagle ]~iver, J~ 99577-3294 (907) 694-3297 fax
July 23, 1996
Jim Cross, P.E.
Manager, On-Site Services
Municipality of Anchorage
P.O. Box 196650
Anchorage, AK 99519
Re: Brewington, Tract D (2)
Narrative & Permit Application
Dear Mr. Cross:
The proposed well and septic system will have very limited impact on adjacent properties for
the following reasons:
1. The surrounding lots are very large, 20 acre tracts, allowing sufficient room for
septic sites.
2. Immediate neighboring septic systems are all +30' distance.
3. Reserve space is adequate, due to absorption capacity and lot size.
4. Drainage will not be affected and is not a major consideration in our design.
If you have any questions please call our office at 694-5195.
Sincerely,
Louis Butera, P.E.
\1996\96-066A-NAR.DOC
I / _
~ I - / / ~ ~' [' PARKING
~ ] DL~ TH ~ ~YSTEM
~ I
~ -~ (BO ACRES)
~ I ~ TEST HOLE
~ ~ ~ · - MONITOR TUBE
~ o - S~ER CL~NOUT
~ ~ - WELL
J ~ ~ - ~SEMENT
PROPOSED L~CHFIELO
~ N 89'50'~1' E
5 13~1.61' ~ NO SURFACE WATER +100'
ND KNOWN CURTAIN DRAINS
ND NEIGHBORING WELLS DR SEPTICS +~00'
TRACT C . TRACT D IS PRDPDSED FOR
SUBDIVISION AS TRACT D-1 AND
WELL/SEPTIC SITE PLAN
LEGAL: BREWlNGTON TRACT D
A EAGLE RIVER ENGINEERING SERVICES ~% ..LOUrS A. 8UTERA.'
P.O. Box 7732~ ~2~ '. cE-s7ss .'
EAGLE RIVER, A~ 99577
(soT) ss~-s~ss ~AX: (907) S~-S2S7 ~
EAGLE RIVER
ENGINEERING SERVICES
P.O. Box 773294
Eagle River, Alaska 99577
(907) 694-5190
ERES Project No.: 96-066
Calculated By: LB
Date: 8/9/96
Legal: BREWINGTON TRACT D-2
Single Family 2 Bedroom Dwelling
TEST HOLE 2
Shallow Trench Subsurface Wastewater Disposal Field
Water use at 150 gallons per bedroom = 300 gallons
Percolation rate = 11 minutes per inch
Wastewater application rate = 0.8 gallons per day per square foot
Required absorption area = 375 square feet
Trench width ON) = 5 feet
Gravel depth (D) = 2 feet
Required length = Shallow trench factor * Required absorption area / W
Shallow trench factor = (W + 2) / ON + 1 +2 D)
Shallow trench factor = 0.70
Total Excavation Depth = 4.0 feet
Required length = 53 feet
SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM
LEGAL:
Brewington Tract D (2)
REVISED 08/09/96
GENERAL
1. The well and septic plan are for a single family residence only.
2. The drawing and or site plan shall be a part of this specification.
3. All materials and workmanship shall meet the Anchorage Department of Health
requirements.
4. All soil tests are advisory to the design and are to be verified or modified in the
field by the engineer.
5. All excavations and depths are advisory and are to be verified in the field by the
contractor to meet Municipality of Anchorage requirements.
6. It is the responsibility of the owner to obtain all necessary permits or easements
and to locate any adjacent multi-family wells.
7. The excavation is to be exactly in the area shown on the site plan, any deviation
requires engineer approval.
8. It is always recommended that a surveyor locate the nearest lot line position and
the location of any easements.
9. Any remaining open test hole excavations shall be filled.
SEPTIC TANK
1. Septic tank shall be 1,000 gallon, minimum, MOA approved.
SHALLOW TRENCH
1. The trench is to follow the natural land contour to maintain uniform total depth
of the trench bottom.
2. The bottom of the trench shall be level, plus or minus 1.5".
3. The total depth of the trench excavation is not to exceed 4' at any point.
4. The effluent line within the trench shall be laid level within 0.03'.
5. The trench gravel is to be covered with typar fabric material.
6. Soil or combination of soil and extruded board insulation to a depth of 3' or
equivalent is to roe placed over the leachfield.
The area over the trench is to be finish graded to prevent ponding of surface
water runoff.
The septic tank and leachfield must not be closer than 100' to any existing
private well, 150' to any Class "C" well, or 200 feet to any community well.
RECOMMENDED LEACHFIELD DIMENSIONS:
TOTAL DEPTH = 4' GRAVEL DEPTH = 2' under pipe, 2" over pipe
TRENCH LENGTH = 53' TRENCH WIDTH = 5'
SOIL RATING = 0.8 GPD/fta BEDROOM CAPACITY = 2
SEPTIC TANK = 1,000 gallons, minimum
Twenty-four (24) hours notice required for all inspections.
\1996\96-066a-spc.doc
SINGLE FAMILY ON-SITE WORKSHEET
ERES PROJECT NUMBER: 96-066 CALCULATED BY:
LEGAL DESCRIPTION: BREWINGTON TRACT D-2
NUMBER OF BEDROOMS: 2
WATER USE PER BEDROOM: 150 GALLONS
PERCOLATION RATE: 11 MINUTES PER INCH
DEPTH TO GROUNDWATER: 9.3 FEET
DEPTH TO IMPERMEABLE LAYER: 14 FEET
ANTICIPATED DEPTH OF COVER: 2 FEET
MOUND OR BED SYSTEM
LB
USABLE SOIL STRATA
TOTAL USABLE DEPTH: 5.3
USABLE SOIL STRATA DEPTH: 3.3
WASTEWATER APPLICATION RATE: 0.5
ABSORPTION AREA REQUIREMENT: 600
MINIMUM BED LENGTH
'i2 FEET WIDE BED 50
15 FEET WIDE BED 40
TRENCH SYSTEM
WASTEWATER APPLICATION RATE: 0.8
ABSORPTION AREA REQUIREMENT: 375
SHALLOW TRENCH OPTIONS
5 FEET WIDE TRENCH
GAL/SQ.FT
SQ.FT
FEET
FEET
GAL/SQ.FT
SQ.FT
DEEP TRENCH OPTIONS
3 FEET WIDE TRENCH
EFFECTIVE REQUIRED TRENCH EFFECTIVE REQUIRED TRENCH
DEPTH (FT) ENGTH (FT) DEPTH (FT) ENGTH (FT)
1 66 4 NA
2 53 4.5 NA
2.5 48 5 NA
3 44 5.5 NA
3.5 NA 6 NA
4 NA 7 NA
8 NA
9 NA
DESIGN SPECIFICS
FIELD SYSTEM: S
GRAVEL DEPTH: 2
TRENCH OR BED WIDTH: 5
LENGTH:
TOTAL
EXCAVATION
DEPTH: 4.0 FEET
(B=BED, S=SHALLOWTRENCH & D=DEEP TRENCH)
FEET
FEET
FEET
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street. Anchorage. Alaska g9502-0650
SOILS LOG -- PERCOLATION TEST
TS'
10
11
12
13
14
15
16-
17-
18-
19
20
Township. Range. Section:
COMMENTS
SLOPE
WAS GROUND WATER
ENCOUNTERED?
E
IF YES, AT WHAT ~/ 0~
SITE PLAN
Reading Date Gross Net Oei3Th to Net
~'/~/,4 ~--~ Time Time Water Orom
~ ~ ~35 I0~//t !~ u/l~,
~ ~ ~, ~ ~(,,1,~"
-- (mlnules~ncnl PERC HOLE DIAMETER __
FTAND 5/ ~'~ FT
PERCOLATION RATE
TEST RUN EETWEEN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS '`ATE. DATE:
72-008 (Rev.
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL
8
9-
10
12
13
14'
t7
18
20-
COMMENTS .
Township, Range, Section:
SLOPE Sn'E
WI'F'H
S
IF YES. AT WHAT 0
E
Deplh to Water After
PERCOLATION RATE ¢//'~'/ (mmutes/mch) PERC HOLE DIAMETER ~ y/
TEST RUN BETWEEN ~"~ FTAND ~'5 FT
FERVOR.ED .~: ~"TN , ~ £~ 5'~ ~: ~,- CERT,P~ THAT TH,S TEST WAS .ERFORMED ,.