Loading...
HomeMy WebLinkAboutSOUTH HILLS BLK 2 LT 2South Hills Block 2 Lot 2 #017-063-05 Development Services Department Building Safety Division .o♦ P, On -Site Water &Wastewater Program 4700 Bragaw Street F.O. Box 196650 _ Mark Be ich Anchorage, AK 99519-6650 Mayor '.' m.'n, "'Vershn (907)343-7904 Pump Installation Log Well Drilling, Permit Number: SW Date of Issue: Parcel Identification Numbertl19(—C63 QS Legal Description � P Tw r N Yet & Address: Pump Installation Date: 7 -a:5 -P7 Pump Intake Depth Below Top of Well C2sing:VV0 feet Pump Afanufacturer's Name: Api -"Wv,po >/n<�• Pump NIodel: 1QP Pump Size / hp Pitless Adapter Burial Depth: /3r feet Pitless Adapter Manufacturer's Name: 17/t Pitless Adapter Installer: /0 Well Disinfected Upon Completion?Yes ❑ No )) M _ ethod of Disinfection: ; �JLIlt� rQ �l o/ 9� I +Y� Comments: I Pump Installer Name ANCHORAGE WELL & PUMP SERVICE, INC ?'30 EAST 76TH AVE. ANCHORAGE, ALASKA 99518 (907)243-0740 - FAX:(907)243-0742 E-MAIL: pumpmanjim@att.net Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. . Municipality of Anchorage Development Services Department •°` ` Building Safety Division On-Site Water & Wastewater Program, 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 - A . z . www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW030499 PID Number: 017-063-05 Name: DON & BARBARA GRAY Wastewater System: ❑ New ■ Upgrade Address: 7246 HILLSIDE WAY * ANCHORAGE, AK 99516 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 345-1009 4 O Deep Trench O Shollow Trench ■ Bed OMound OOther LEGAL DESCRIPTION Soo Rating: Total Depth from original grade: 2.0 GPD/Sq. rt. 3.5 (MAX) rt. Block: Lot: Subdivision: 2 2 SOUTH HILLS Depth to pipe bottom from original grade: Gravel depth beneath pipe: SEE DWG. FL 0.5 F. Township: Range: Section: — — —grade: Fill added above original Grovel length: SEE DWG. Ft. 30 FL WELL❑ New ❑Upgrade Gravel width 10 � Number of Ones: Datonce between lines: 5 (Private. A B,C): Total Oe Cord To: Total absorption area: Ft. 2 Ft. Pipe material: FL FL 300 so. FL D 3034/ F-810 Driller Date Drilled: Static Water Level: Ft.AKWWC, Installer. INC. Data Installed: 12/10-11/2003 Yield: Pump Set At Cooing Height Above Ground: GPM Ft. TANK SEPARATION DISTANCES 0Septic 0Holding ■S.T.E.P. ■other To From Septic Tank Absorption Field Lift Station Holding Tank Public/Private Sewer unes Manufacturer. ORENCO SYSTEMS Capacity in gallons: 1500 Well 100'+ 100'+ - - 25'+ Material` FIBERGLASS Number of compartments: 2 Surface water 100'+ 100'+ — — — LIFT STATION Lot Line 5'+ **5'+ — — _ Size In gallons' Manufacturer. 1500 ANCHORAGE TANK ORENCO SYSTEMS Foundation 5'+ 10'+ — _ _ 'Pump on' level at: 'Pump off' level at: High water alarm at TIMER TIMER 1 46'0-- 6"Curtain CurtainDrain NONE KNOWN Pump Make k Model: Electrical Inspections performed by: #20 OSI OS HHF M.O.A. Remarks: BENCH MARK *THIS IS AN ADVANTEX TREATMENT SYSTEM Location and Description:TOP OF GARAGE FLOOR SLAB **WAIVER GRANTED Assumed Elevation: 103.93 rL ENGINEER'S SEAL OF b �� Inspections performed by: AKWWC, INC. Dates: 1st 12/10/2003 4 �..;. 12/10/2003 „ : „ Q 2nd 3rd 12/11/2003 ..... _ e f A. Garn ss.: Development ices Department Approval d�9 s .goo Reviewed and approved by: Date:0¢ ��4p p o�F,00 \ (Rev. 12/01) ro f e s s(an O�O�o�oo PERMIT NUMBER: AS—BUILT DRAWING PARCEL ID NUMBER: SW030499017-063-05 01 11 ST1 114.86 117.49 MH 119.37 125.17 DBL1 122.72 128.13 DBL2 1123.62 128.79 FD 188.36 48.76 MT1 1138.61 140.73 C01 1129.201122.08 CO2 122.74 116.49 MT2 1121.281115.531 NEW DRAINFlELD a TH#2 CID INSTALLED FLOWI `• •,'' DIVERTER o �iy I //'�� `• •.�• 1 il, cow +'FCOI, I I ---- JA \ANEW 1500 GALLON ADVANTEX TREATMENT SYSTEM i 10 FEET UTILITY EASEMENT J EXISTING SEPTIC SYSTEM TO BE USED AS A RESERVE SfiE i I / / TH11 % I LINE UNDER DRIVEWAY�= =s` INSTALLED DOUBLE C�O� \ / INSULATED WITH 6INCHES ��.: \ k I / IBLUEBOARD \ 6 N ULATIONF4 FEET WIDE � I a TH#2 CID INSTALLED FLOWI `• •,'' DIVERTER o �iy I //'�� `• •.�• 1 il, cow +'FCOI, I I ---- JA \ANEW 1500 GALLON ADVANTEX TREATMENT SYSTEM i 10 FEET UTILITY EASEMENT 12/17/2003 DRAWN BY. ALASKA NVATER & WASTE NNAT.ER C.J.G. . e - CONSULTANTS, INC. SCALE: 5701 E. TUDOR ROAD. SUITE 101 •ANCHORAGE. AR 99507 •PHONE (907)357-6179 •FAX (907)558-321.6 1" = 40' PREPARED FOR: PHONE NUMBER: PAGE NUMBER: DON & BARBARA GRAY (907) 345-1009 2 OF 3 LEGAL DESCRIPTION: SOUTH HILLS, SUBDIVISION; LOT 2, BLOCK 2, TYPE OF WORK: AS—BUILT DRAWING OF SEPTIC SYSTEM UPGRADE .i0F 0 are • ...... • • . 'WlflofesslO 0\ % I � I 12/17/2003 DRAWN BY. ALASKA NVATER & WASTE NNAT.ER C.J.G. . e - CONSULTANTS, INC. SCALE: 5701 E. TUDOR ROAD. SUITE 101 •ANCHORAGE. AR 99507 •PHONE (907)357-6179 •FAX (907)558-321.6 1" = 40' PREPARED FOR: PHONE NUMBER: PAGE NUMBER: DON & BARBARA GRAY (907) 345-1009 2 OF 3 LEGAL DESCRIPTION: SOUTH HILLS, SUBDIVISION; LOT 2, BLOCK 2, TYPE OF WORK: AS—BUILT DRAWING OF SEPTIC SYSTEM UPGRADE .i0F 0 are • ...... • • . 'WlflofesslO 0\ 1 PERMIT NUMBER: SW030499 AS -BUILT DRAWING PARCEL ID NUMBER: 017-063-05 1 TH#2 FINAL GRADE - 97.13 (AVG.) TOP OF TANK - 94.15— TOP OF ADVANTEX POD - 97.68 (AVG.) — - INLET - INVERT OF PIPE - 93.14— I.V 1 1506 GALLO, ADVANTEX 11,TANK FINAL GRADE 96.64-97.21 FABRIC 2 5 FEET OF iA.OA' SAND nLTER"- .."*...**.""--".*,--.v:. TOP OF SAND 92.93 (A BOTTOM OF S)7.)M G, - 90.43 (AVG. RELATIVE ELEVATION OF BOTTOM OF TEST HOLE - 1.93 (ELEVATION OF IMPERMEABLE SOILS 88.43) DATE: 12/17/2003 at t DRAWN BY: ALASKA AVATE R & INAS TE NNIATI E RC.J. G. CONSULTANTS, INC. SCALE: 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE. AK 99507 * PHONE (907)337-6179 1 FAX (907)338-3246 N.T.S. PREPARED FOR: PHONE NUMBER: PAGE NUMBER: DON & BARBARA GRAY (907) 345-1009 3 OF 3 LEGAL DESCRIPTION: SOUTH HILLS SUBDIVISION; LOT 2, BLOCK 2, TYPE OF WORK: PROFILE AS—BUILT DRAWING OF SEPTIC SYSTEM UPGRADE TOP OF MANHOLE 97.13 (AVG.) P OF TANK - 94.15 , ORIGINAL GRADE 0 HIGHEST POINT - 93.93 INVERT OF DISTRIBUTION LINE - 93.45 (AVG.) RightFax 12/17/2003 5:24 PAGE 1/1 RightFax Inspection Report Municipality of Anchorage, Building Safety. Division 4700 South Bragaw INSPECTION: VOICE 343-8300 INSPECTION: FAX (907)249-7777 INFO: 343-1062 Name dove Permit 03-3540 Address NHN HILLSIDE WAY Phone 272-0972;, Legal j Inspection Date 12/18/2003 Subdlvlslon SOUTH HILLS Comments or.Dlrectlona Inspection Retro Electrical Reinspection , Y NO NONCOMPLIANCE OBSERVED II ❑ ; CORRECTIONS ESSENTIAL AS EXPLAINED BELOW WILL RE-EXAMINE AT NEXT DO NOT CONCEAL UNTIL REINSPECTION INSPECTION i COMMENTS: (for Inspector use only) i i LCL ►�%�r� J �r l d�d, t ✓ Inspector Date. ,i 'i MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW030499 Legal Description: jSOUTH HILLS BLK; Design Engineer: 0041 AK Water & Wastewater Consultant Owner Name: Don & Barbara Gray Owner Address: 7246 HILLSIDE WAY ANCHORAGE, AK 99516-3741 iDpM �Z. 31D P „ ?�'�Deff Date Issued: Dec 04, 2003 Expiration Date: Dec 03, 2004 Parcel ID: 017-063-05 Site Address: Lot Size: 72000 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: Date: Municipality of Anchorage a� Development Services Department Building Safety Division t c " On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 .ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING i Parcel I.D. ���—���—� S Permit Number 5-w03404g9 Property owner(s) DON AND BARBARA GRAY Day phone 345-1009 Mailing address (1) 7246 HILLSIDE WAY * ANCHORAGE AK Mailing address (2) Zip Code 99516 Legal description (Lot, Block & Sub'd.) LOT 2. BLOCK 2: SOUTH HILLS S SUBDIVISION Legal iodescription (Section, Township & Range) N/A Lot Size �? . O 0 y Acre Sq.Ft. Number of Bedrooms 4 THIS APPLICATION IS FOR: Sewer Only ❑ 1 Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade 0 THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. ALASKA WATER & WASTEWATER CONSULTANTS INC. Permit Fees: _ `'(yy Date of Payment: Receipt Number. Waiver Fees: 1 <�� Date of Payment: ' W Receipt Number. �� `"t ALASKA WATER � WASTEWATER CONSULTANTS, INC. REVISED December 3, 2003 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Septic System Upgrade on Lot 2, Block 2; South Hills Subdivision ADVANTEXT"TREATMENT SYSTEM To whom it may concern: 1. GENERAL: The existing 4 bedroom house is served by a on-site well and septic system. The septic system consists of a 1250 gallon concrete septic tank and a concrete ring seepage pit type drainfield. The drainfield is in a state of failure and must be upgraded in order to sell the house. Two test holes were excavated on the property. We are proposing to design the septic system around the 30 foot radius of test hole 42. Due to the poor soil conditions and the small area around the test hole, we are proposing to use an Advantex treatment system and a bed type drainfield. 2. SOILS: See the attached logs, which shows the soil classifications, groundwater monitoring, and the percolation test results. 3. DRAINFIELD APPLICATION RATE: A percolation test was performed in test hole #2 between the depths of 2.5 to 3.0 feet and 4.0 to 5.0 feet and found the rates ranged from 5 to 24 minutes/inch. The Advantex system has received class III approval and due to the visual appearance of the soils, we are going to conservatively assume an application rate of 2.0 GPD/FT2 (see attached M.O.A. Engineer Bulletin 2000-1). 4. TRENCH DESIGN: a. Percolation Rate: 5 & 24 minutes/inch b. Proposed Application Rate: 2.0 gallons/day/ft2 c. Number of Bedrooms: 4' d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 300 ft2 3701 E Tudor Road, Suite 101 —Anchorage, AK 99504 Ph: (907)337-6179 — Fax: (907)338-3246 — Website: akwwc.com f. Total Depth: 3.5 feet (maximum) g. M.O.A. Approved Sand Filter: 2 to 3 feet h. Effective Depth: 0.5 feet i. Width: 10 feet j. Minimum Length: 30 feet long k. Effective absorption area: 300 f12 5.ORENCO PACKAGE SYSTEM: The STEP tank with the Advantex Treatment System will be manufactured by Anchorage Tank & Welding to meet the latest design criteria established by Orenco Systems, Inc. The point of contact at Anchorage Tank is Lowell McNutt. As with their standard STEP tank, it is equipped with a high water alarm per M.O.A requirements. 6. SURFACE WATER: There is no surface water within 100 feet of the proposed septic system upgrade. 7. TOPOGRAPHY: As can be seen on the attached design, the proposed drainfield is to be installed on a 5± percent slope. In short, there are no slope concerns. 8. WAIVER TO IMPEARMEABLE SOILS: A visually rated impermeable layer was found at a depth of 5.5 feet in test hole 42. We are requesting that the vertical separation distance between the bottom of the drainfield, and the impermeable soil layer, be waived to 4 feet. Justification for this reduced separation distance is summarized as follows: • The effluent being discharged to the drainfield is from an Advantex treatment system, which has CBOD and TSS levels that are expected to be less than 10 mg/L. In addition, the total nitrogen levels are expected to be less than the effluent from a lined Intermittent Sand Filter (effluent from an ISF can be discharged into a drainfield that is only 4 feet from bedrock and impermeable soils) • There will still be a 4+ feet separation distance between the bottom of the drainfield and groundwater • There will be no discernable benefit (reduced BOD, TSS, or total nitrogen) achieved by passing the effluent through 6 feet of soil vs. 4 feet of soil. It is generally agreed upon that the pathogen reduction occurs within the first 4 feet of soil, hence the 4 feet required separation distance to groundwater. It is reasonable to assume that by the time the effluent passes through 4 feet of the insitu 5 & 24 minute per inch soil that the BOD and TSS levels will be essentially zero (0). It is further assumed that there will be no more reduction in total nitrogen achieved by building the mound several feet higher. The highly treated effluent will probably not see further reduction in nitrogen levels without introduction of a carbon source (as is the case with ISF effluent). • As can be seen on the attached soil log for test hole #2, the soils between 1.5 to 3.5 feet is a mostly silt (ML) and the soils between 3.5 to 5.5 feet is a mixture of gravel and silt (GM/ML). Based upon these soil conditions, it is our opinion that there is an adequate silt content to treat the effluent from the Advantex treatment system • As can be seen on the attached site plan, the population density of the area is low. In short, it is our opinion that there is minimal to no risk on the neighboring properties with the granting of this waiver. Based upon the facts presented, we are requesting that the vertical separation distance between the bottom of the proposed drainfield and an impermeable soil layer be reduced to 4 feet. 3701 E Tudor Road, Suite 101 — Anchorage, AK 99504 Ph: (907)337-6179 — Fax: (907)338-3246 — Website: akwwc.com 9. LOT LINE WAIVER REQUEST: We request a 5 foot lot line waiver from the northwest property line to the proposed drainfield. We are unaware of any adverse effect on the road right of way with the granting of this waiver. 10. CLOSING: I am open to any suggestions from your department that would be an improvement to the proposed system. I am unaware of any negative impacts that this installation would impose on adjacent wells, or septic systems. If you have any questions, please call us at 337-6179. '.E., M.S. NOTE: Attached is a site plan drent,ing, a design draining, an Advantex detail, a bed detail, t►vo soil logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 3701 E Tudor Road, Suite 101 — Anchorage, AK 99504 Ph: (907)337-6179 — Fax: (907)338-3246 — Website: akwwc.com , 105 SOUTH HILLS S/D; LOT 4, BLOCK 1 THj1♦ I I PROPOSED SEPTIC UPGRADE (SEE DESIGN, PAGE 2 OF 4) /D: s \ SLOT 5. LLOOCK 1 NO ENCROACHMENT `a_ j 1 CONCERNS 100• WFI IBJ A l I'C J I I ice `! I EXISTING M / 4 BEDROOM)) / I HOUSE I I / SLOT 2. LOCKHILLS /1 l \�lJs 1�. w us 1 I I I ' / SOUTH HILLS S/D; / LOT 3. BLOCK 1 \A - SOL" HILLS S/0; LOT 1, BLOCK 1 r ' f T°O' µ6f I �91 ?9p/_s � I + I I 1 I / \ I I LOSOUTHN . BLOCK 2. I NO ENCROACHMENT + CONCERNS I I I I I I I I I 1 + SOUTH HILLS S/D; LOT 4. BLACK 2 i i I �P" I I 1 i - - - - - - - - - - - - - - I I I 1 I SOUTH HILLS S/D; LOT 5. BLOCK 2 + 1 I I CPQ I I I I i ALASKA. INIATER & WASTE NAIATER CONSULTANTS, INC. 3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE. AK 99507 • PHONE (907)337-6179 • FAX (907)338-321.6 PREPARED FOR PHONE NUMBER: DON & BARBARA GRAY 345-1009 LEGAL DESCRIPTION: SOUTH HILLS SUBDIVISION; LOT 2, BLOCK 2; TYPE OF WORK: SITE PLAN FOR SEPTIC SYSTEM UPGRADE DATE: 11/18/2003 EXISTING SEPTIC SYSTEM I I SOUTH HILLS S/D; LOT 1, BLOCK 2 NO ENCROACHMENT CONCERNS i I I i I I L--------------- -------------- SOUTH -------------- --------------SOUTH HILLS S/D; LAT 6, BLOCK 2 I I I � I I I I WN BY:,='C .� ► .'il J.L.M. LE: vw 1" = 100' ..... ..... E NUMBER: .. ... ... ..... 1 OF 4 e fr y A. am s; 79 � f � c J1+�1* ewe ' • ...... • •; ��.o,�:-:'' 1�k It ProfeSSionO NOTE: THE CONTRACTOR SHALL HAVE THE NORTHWEST LOT LINE AND THE 100 FEET / WELL RADIUS FLAGGED BY A REGISTERED / LAND SURVEYOR PRIOR TO CONSTRUCTION. r � I r I EXISTING SEPTIC SYSTEM TO \ BE USED AS A RESERVE SITE THIll / ``c •' �. <�% \ INSTALL INSULATE UNE UNDER DOUBLE `'' ...• •� DRIVEWAY WITH 4 INCHES OF CLEANOUTS / p�Jp / ���;�. •`. �1 RIGID INSULATTION 4 FEET WIDE \ CO \ Co o ` ti II'i c •' INSTALL FLOWDIVERTERr zg FCO/ I I '_�---------- '' 60 s I i \ PROPOSED 1500 GALLONINSTALL / FIBERGLASS ADVANTEX rn DOUBLE TREATMENT SYSTEM (SEE DETAIL o CLEANOUTS \ DRAWING, PAGE 3 OF 4) PROPOSED DRAINFIELD. EXCAVATE A BED / I THAT IS 3.5 FEET DEEP MAXIMUM BY 10 / I FEET WIDE BY 30 FEET LONG. ADD 2.0 TO 3.0 FEET OF M.OA. APPROVED SAND o I FILTER AND THEN 0.5 FEET OF CLEAN, NOTE: ALL SEWER LINES MUST HAVE WASHED SEWER DRAINROCK. (SEE DETAIL 3+ FEET OF COVER OR MUST BE DRAWING, PAGE 4 OF 4) INSULATED WITH 2 INCHES OF RIGID I INSULATION WITH 2+ FEET OF COVER. - -— J 10 FEET UTILITY EASEMENT V 11/18/2003 DRAWN BY: ALASKA. INATER & WASTE AVATER SALE J.L.M. oQV� CONSULTANTS, INC.4 1 " = 40' PA ............... 3701 E. TUDOR ROAD. SUITE 101 •ANCHORAGE. AK 99507 •PHONE (907)337-6179 •FAX (907)338-5246 D PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ..... .. ........ ..... DON & BARBARA GRAY 345-1009 2 OF 4 e ey , ornes * O LEGAL DESCRIPTION: Ovo4r C —79 GZQ� SOUTH HILLS SUBDIVISION; LOT 2, BLOCK 2, s ,moo TYPE OF WORK: ��Deap�ofessto�o�� DESIGN OF SEPTIC SYSTEM UPGRADE (ADVANTEX TREATMENT SYSTEM) �DO0000� AdvanTex' Treatment System AX20 - Mode 1a 40x94Pod 3-4 bedrooms tori Orenco SystemsO l—'parol 6• ,nM 6- 6' GWED AX20 POD DATE: .. 4z. 11/18/200; iL as q DRAWN BY: ALASKA N'E'ATER & WASTE INATERSCALE.J•L.M. CONSULTANTS, INC. 3701 TUDOR ROAD, SUITE 101 • ANCHORAGE. AK 99507 • PHONE (907)337-6179 *.FAX (907)338-3246 N.T.S. PREPARED FOR: PHONE NUMBER: PAGE NUMBER: DON & BARBARA GRAY (907) 345-1009 3 OF 4 LEGAL DESCRIPTION: SOUTH HILLS SUBDIVISION; LOT 2, BLOCK 2, TYPE OF WORK: DETAIL DRAWING OF ADVANTEX TREATMENT SYSTEM (AX20 MODE 1a) ... f . y ry�ess:.. . 9 E 7953' A 40��-ro f es sloe°o UFTSTATION 1 ! i OPTIONAL i ilI 1500. GALLON I SURE SECTION " ADVANTEX TANK OF V PIPE OVER ! ! ! 1 THIS CONNECTION E TO PROVIDE SHEER PROTECTION- EXTEND TO BRIDGE EXCAVATION DATE: .. 4z. 11/18/200; iL as q DRAWN BY: ALASKA N'E'ATER & WASTE INATERSCALE.J•L.M. CONSULTANTS, INC. 3701 TUDOR ROAD, SUITE 101 • ANCHORAGE. AK 99507 • PHONE (907)337-6179 *.FAX (907)338-3246 N.T.S. PREPARED FOR: PHONE NUMBER: PAGE NUMBER: DON & BARBARA GRAY (907) 345-1009 3 OF 4 LEGAL DESCRIPTION: SOUTH HILLS SUBDIVISION; LOT 2, BLOCK 2, TYPE OF WORK: DETAIL DRAWING OF ADVANTEX TREATMENT SYSTEM (AX20 MODE 1a) ... f . y ry�ess:.. . 9 E 7953' A 40��-ro f es sloe°o ORIGINAL 30 FEET LONG r-----------------------------------------------� I MT I I 0 I I I I CD I I I I I I I i 4' PERF. PIPE I I I I I CID I O I I I L -- ------------------------------------------ J --FINAL GRADE 2+ FEET OF COVER :TER FABRIC 4+ FEET TO IMPERMEABLE SOILS (SEE WAIVER REQUEST) AND TO GROUNDWATER NAL GRADE y�I�f: 'j1��:/ �:i►� ��%ii� �f�1�i1�I�I�f�1�i►�l►�I�i►�I�1, }`I�I�i iii" i�`I�f�1 DRAWN BY: J•L•'"'• 4 ALASKA. INIATE R & VVASTE�'VATER 9 Ste' - CONSULTANTS, INC. ' 3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE, AK 99507 • PHONE (907)337-6179 • FAX (907)338-3246 • PREPARED FOR: PHONE NUMBER: PAGE NUMBER: DON & BARBARA GRAY 345-1009 4 OF 4 DO ffr Go a s- 4+ FEET TO IMPERMEABLE SOILS (SEE WAIVER REQUEST) AND TO GROUNDWATER NAL GRADE DATE: 11/18/2003 04 F DRAWN BY: J•L•'"'• 4 ALASKA. INIATE R & VVASTE�'VATER 9 Ste' - CONSULTANTS, INC. ' 3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE, AK 99507 • PHONE (907)337-6179 • FAX (907)338-3246 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: DON & BARBARA GRAY 345-1009 4 OF 4 DO ffr Go a s- LEGAL DESCRIPTION: SOUTH HILLS SUBDIVISION; LOT 2, BLOCK 2, p� _ p Prof eass�o�o\ co �Orof �4 TYPE OF WORK: DETAIL DRAWING OF PROPOSED DRAINFIELD ALASKA WATER & WASTEWATER CONSULTANTS, INC. Ol E. TUDOR ROAD. SUITE 101 • MCHORAGE. AK. 9950 • HON • 907 —61 9 • FAX. (907)338-3246 • WEBSIT okwwc.coi SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: SOUTH HILLS SUBDMSION; LOT 2, BLOCK 2 PERFORMED FOR: DON GRAY DATE: 11/5/2003 (f (feet) ORGANICS TEST HOLE #1 (PAGE 1 OF )) 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 GM/SM/ML SOIL CLASSIFICATIONS DATE GW rORG ;,., _... 11/13/2003 ML I I (.I I GM CL UPPER 2 BENCH 3 GC�; OL °o ° o SW MH gotESC SPCH 2 3/4" 1 SM � �' ,' OH 1 1 1 , — MPERMEABLE) DEPTH TO GROUNDWATER DATE DRY 11/5/2003 DRY 11/13/2003 DRY 11/18/2003 I — ....... .. . . .............. I. .: f A... .r S ....... C 7953 Q n `1 4044I'pro f e s stonooc DATE READING 19 1 , / THJI I 1 4:47 1 I — UPPER 2 BENCH 3 1 � 2 3/4" 6" 3 1/4" — 4 5:47 30 2 3/4" 1 5 #2 F J' 1 1 1 , — , 6:17 30 2 3/4" 3 1/4- /4" EXISTING i 4 BEDROOU \ e/HOUSE I ------------ - �� _ _ _—�-----------�--- -------------------------------- SITE PLAN - I 1 "=100' DATE READING 19 CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 11/12/2003 1 4:47 — 6" — UPPER 2 BENCH 3 5:17 5:17 30 — 2 3/4" 6" 3 1/4" — 4 5:47 30 2 3/4" 3 1/4" 5 5:47 — 6" — 6 6:17 30 2 3/4" 3 1/4- /4" 19 PERCOLATION RATE 9.2 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 2.5 FT. AND 3.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: NICK HEITSTUMAN COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W P FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: h0 -04v pQ'0� ALASKA WATER & WASTEWATER 4 CONSULTANTS, INC. �' •'yam �O 0. SUITE 101 - ANCHORAGE. AK. 99507 - PHONE* — — • o wwc.co ... ... ...........� SOIL LOG - PERCOLATION TEST . LEGAL DESCRIPTION: SOUTH HILLS SUBDMSION: LOT 2, BLOCK 2 -J f Gi imess: PERFORMED FOR: DON GRAY DATE: 11/5/2003 4 TH 'clp (feet] TEST HOLE # 1 �r000l 1 (PAGE 2 OF 2) SOIL CLASSIFICATIONS 2 GW ORG GP ML I^�j I I W I GM CL 4 GC OL °o o SW MH SP 5 NCH SEE SITE PLAN SM ,' OH 6 0 SC PAGE 1 OF 2 w 7 naDEP'TH TO GROUNDWATER DATE $ o 9 w SEE Q PGS 0 10 � cn w 11 ~ o: TIME (MINUTES) READING (INCHES) 0 12 z 0 13 3 6:09 — 6 1/2" — v in14 g U 15 '' 0 16 w cn 17 18 19 PERCOLATION RATE 120+ (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 5.0 FT. AND 5.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ED NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: NICK HEITSTUMAN COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W S ERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 111!7 3 DATE READING CLOCK NET TIME WATER LEVEL NET DROP 11/6/2003 1 5:39 — 6 1/2" — LOWER BENCH 2 6:09 30 6 1 /2" 0" 4 6:39 30 6 1 /2" 0" 5 6:39 — 6 1 /2" — 6 7:09 30 6 1 /2" 0" AILASKA WATER & WASTEWATER CONSULTANTS, INC. SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: SOUTH HILLS SUBDIVISION; LOT 2. BLOCK 2 PERFORMED FOR: DON GRAY DATE: 11/10/2003 DEPTH ---- (feet) ORGANICS TEST HOLE #2 (PAGE 1 OF 2) 7 9 VISUALLYLRATED IMPERMEABLE 10- 11 12 B.O.H. 13- 14- 15- 16- 17] 314151617 18 SOIL CLASSIFICATIONS DEPTH TO GROUNDWATER GW ORG GP ( ML GM CL GC OL SW MH SP CH SM ,' OH DRY IMIM DRY 11/13/2003 ': �'• : • It 4:52 SC DEPTH TO GROUNDWATER DATE DRY 11/10/2003 DRY 11/13/2003 DRY 11/18/2003 4:52 - DATE READING CLOCK TIME NET TIME (MINUTES) TH#1. I ; 11/12/2003 1 4:52 - 6 - UPPER BENCH 2 5:22 30 4 3/4" 1 1/4" 3 5:22 - 6" - 4 5:52 30 4 3/4" /4"5 1 1/4- 5 5:52 - 6" - EXISTING i 6:22 30 4 BEDR001� ; �,-HOUSE -------------- �� _--_---------------�--- ------------- -------------------- SITE PLAN L:_ DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 11/12/2003 1 4:52 - 6 - UPPER BENCH 2 5:22 30 4 3/4" 1 1/4" 3 5:22 - 6" - 4 5:52 30 4 3/4" /4"5 1 1/4- 5 5:52 - 6" - 6 6:22 30 4 3/4" 1 1/4" 19 PERCOLATION RATE 24 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 2.5 FT. AND 3.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: NICK HEITSTUMAN COMMENTS: PERFORMED BY AKWWC, INC. [.-JEFFREY A. GARNESS, CERTIFY THAT THIS WAI PEWORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:1 Zb O ALASKA NATER & WASTEWATER•.yap0 CONSULTANTS, INC.701 L TUDOR ROAD. SUfTE 101 * ANCHORAGE. AK. 99507 6-PHONL- O _ _ a ..Gc Q .......D SOIL LOG — PERCOLATION TEST O „ • fn: LEGAL DESCRIPTION: SOUTH HILLS SUBDIVISION; LOT 2, BLOCK 2 .Je ss.: 795 ` D PERFORMED FOR: DON GRAY DATE: 11/10/2003 Q4'sf�' •' Atic°iz,OD (feet) 44��� rofess�000G— TEST HOLE 2 00000 1 (PAGE 2 OF 2) SOIL CLASSIFICATIONS 2 GW ORG GP ML I , GM CL 4 GC OL °o o ° o SW MH ': SP 5 CH SEE SITE PLAN U.NCH SM OH 6 Sc PAGE 1 OF 2 W 7 a DEPTH TO DATE GROUNDWATER g o 04 � 1 OF 2 9 W 0 x 10 11—DATE READING 0 12 z LOWER 0" 6" 0 13 v N 14 U 15-0 ul 16 W in 17 18 19 PERCOLATION RATE 5 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4.0 FT. AND 5.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: NICK HEITSTUMAN COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WA P FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: I o CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 11/12/2003 1 4:54 — 6" — BENCH 2 5:24 30 3 5:24 — 6" — 4 5:54 30 0" 6" 5 5:54 — 6" — 6 6:24 30 0" 6" Municipality of Anchorage Department of Health and Human Services 825 "l-° Street Rick Mystrom. P.O. Box 196650 Anchorage, Alaska 99519-6650 Mayor http'//wwn.ci.anchorage.ak.us ENGINEER BULLETIN 2000-1 July 7, 2000 TO: Engineers involved with the Design, Inspection and construction of On -Site Water and Wastewater Disposal Systems. r SUBJECT: I. Application rates for Advanced Wastewater System Technologies. H. Requirements.for the Design and Installation of HDPE Septic Tanks. ? 1.3 4 J I. Effective immediately, application rates for all approved advanced wastewater system j ; technologies will be calculated according to the following table: d j All Categories must use a sand filter layer in gravel soils which have a percolation rate of less than 1 minute per inch. Soil Percolation Rate Category II System Category III System 1-5 4 galJday/ 6 gal./day/ft- 6-15 3 galJday/ 5 gal./day/ 16-30 2 galJday/ff 4 gal./day/ft 31-60 1 galJday/ft 2 gal./day/ft 60-120 0.5 galJday/ft 0.5 gal./day/ft Note: The above application rates are valid for systems using a discharge pump only. Systems using gravity feed only shall be allowed 50% -of the above application rates. For clarification, Category 11 Systems currently approved include the BioCycle System and the Reactex (Upflow) Filter System. Category III systems currently approved include the Intermittent Dosing Sand Filter. II. Effective immediately all permit design submittals for wastewater disposal systems must state the type of septic tank proposed for use (steel, concrete or HDPE). All permit design submittals using HDPE septic tanks shall include seasonal high water table information for the proposed location of the septic tank. Note also that the maximum burial depth for HDPE septic tanks is 4 feet from top of tank to finish grade. If the tank type is changed to HDPE after the permit is issued, the DHHS must be notified, and the necessary ground water and burial depth information must be subm�ed prior to installation. crely, 1 s Cross, P gram Manager, On -Site Services • it ;Building Safety Division];i On -Site Water and Waste%nrater Program I i' 'I I ;III 4700,South Bragaw St. ! s E T Y 1 ? P.O. Box 196650 Anchorage, AK 99519-6650 www.oi.anchorage.ak.us " I' I' (907) 343-7904:.;, P J' i' ON-SITEISEWERMELL SUBMITTAL COMMENT SHEET j To: ALASKA WATER A WASTEWATER CONSULTANTS INC.; { ,I lig • I , Legal description: SOUTH l-IILLS SUBDIVISION BLOCK 2 !LOT 2 I ,I r I I r The attached paperwork has been reviewed and is being returned Ifor the following reasons: i I I I � I, { il' I,` -..I II' �I r'� I �I � il' a, II,'•` I, Original signature or stamplmissing on j' ❑ Calculation error in design!, j I• I ;n I 9r I' I Ili ' { I I I 1. I' ❑ Additional soils information needed.; ,: Water monitoring results' inadequate I I, I Ili I I •I � j� , II ❑ Discrepancy in information �submittetl I ❑ Topographic information missing for inatlequate I f j j ❑ Incomplete; missing i I i ! i � Incom tete• missin i � I c ❑ P 9 , I I t' I ;�! Iw II � � i. I Illlr I t i eedled. al de uac test informat on n Addition a III { ❑ I I q Y I. I I I j �I Water sam` le unacce' table. r P P, I I I , qJ; iii., ., I , II ❑ Measured!proposed 'distancesldimensionsmissing. ISI, I. Ic "III,,. I� '', Locations of all soils, percolation and water monitoring tests not shown. ; I'I d I i . c Proposed system too deeplfor.soils information submitted. ` I I I ' II IL': I -IIS l II i I I:IIj°I D;; S I I I 1. ❑ Well log required I; I I� ❑ Omission in ;narrative i I I I I I, I. I I ,I r � I tank or field. I I Insufficient fill'over ,r I III, , 1:��, ® Other. PLEASE TALK�SOME IN THE (VERTICAL' WAIVER (REQUEST ITO 1�IMPERMEABLE SOILS :1THAT., DENSITY ' IS LOW 1 I IN i THE III AREA' I' I, & 11 SOILS 111 HAVE 11 'ADEQUATE SILT j CONTENT FOR ADEQUATE TREATMENT OF SEPTIC TANK (EFFLUENT &I ETC. Name of reviewer: DAN Date: 12/2/031 • I I t i it .'�' I I11 'I and re' submit our re uest. Please su 1 ,the necessar information , 'I ! AA Y Y Y I q i I `I II, I, Ir I, IIS �I{ I! I' I,iI !i' ilsl I 1 I Ir,f l (III i I I I � I ' i 'ItP I •!' j' II il. ' j;f ( ,, I II ' LEAVE THIS FORM jATTA CHED;jTO THE PAPERWORK; 1 i .I L� I i� ,tii C � � II 1Y;' II I I 'r I III•( � II , II'I I ��'I' I I I I' ''; I II {:, II i� , 'I ' •i •JII i„ !I' I ;• I I I Municipality of Anchorage Mark Begich, Dlayor Building Safely Division P.O. Box 196650. 4700 Bragaw Street Anchorage, Alaska 99519-6650 • (907) 343-83019 Fax (907) 343-8200 littp:H%v%%iv.mttn i.org November 21, 2003 Jeff Gamess, PE Alaska Water & Wastewater Consultants, Inc. 3701 E. Tudor Road, Suite 101 Anchorage, Alaska 99507 Subject: Waiver Request for South Hills Block 2 Lot 2 Waiver Request # WR030108 PID #017-063-05 Dear Mr. Gamess: Your request for waiver of the required 10 feet horizontal separation from a property line to a wastewater absorption field has been approved. The approved separation distance is 5 feet from the Northwest Property Line to the proposed Drainfield. This waiver approval applies to the existing on-site wastewater disposal system to property line separation only. Any future upgrade to the on-site wastewater disposal system will required all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343- 7904. Sincerely, Daniel Roth Civil Engineer On -Site Water & Wastewater Program Municipality of Anchorage Development Services Department • Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak-.us (907)343-7904 WR#: 030108 PID#:017-063-05 Date Received: 11121103 Waiver Review Worksheet HAM Permit#: Legal Description: South Hills Block 2 Lot 2 Engineer: Alaska Water & Wastewater Consultants, Inc. 3701 E. Tudor Suite 101 Applicant: Don & Barbara Gray n Sf E T Y Waiver Requested: 5 foot Lot Line Waiver from the Northwest Property Line to the proposed Drainfield Criteria: Geology A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: Points: ............................................................................... Waiver is Granted: X Waiver is not Granted. List Conditions or Reasons for above: S 5E 4*6I EER 15' r :4 F_D L F r -E,? o F Tl(S T I P C/4I -�Oti jo4rr-n rHIS Appy oww- �9LS'O IAICLUtil=S It.A1VF/? TO TMPER'VrQ .4"PHL1ftpE p -Y TYPSOILS GF � /'Vy-p or TKE JP�QI�lgco 7141 IJ *1/- $0 Tu S Tf Fi Et% /,v Tlt(C- Eiv� ��vFEIQ' S L F_ TIER. Date: 12 0 3 By: V 4 N Name of Reviewer ............................................................................... Rec#: 44843 Amount: $150.00 Date Paid: 11/21/2003 GRED l.R ANCHORAGE AREA BW1JGH n ON � Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME 6/L z SL' MAILING ADDRESS�d'Ul% l� / /%1L/� GCYO PH 0NEJ�r/-lJ/sf� LOCATION ��G� ��� �� y�%� LEGAL DESCRIPTION SEPTIC TANK: DISTANCE NUMBER OF FROM WELL,"f/� MANUFACTURER f �/�/�f� MATERIAL%�<'>�y 4� COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY 5 �� GALLONS. SEEPAGE PIT: NUMBER OF PITS DIAMETER __ OR WIDTHS-' LENGTH DEPTH _ 1 ✓'�/ 1; /-5 / -i`; . lii /GL/.3 c°�%✓L ' tel✓ C-3 ) i LINING MATERIAL CRIB SIZE: DIAMETERDEPTH � DISTANCE FROM: WELLfJ'� hfGr�= TOTAL EFFECTIVE BUILDING FOUNDATIONLZ' NEAREST LOT LINE tz/ ABSORPTION AREA (WALL AREA) / SQ. FT. ADDITIONAL ABSORPTION _ /!/SGL �✓Gi���s� �%C�jUE'L. .�/��.G��/c.L WELL: TYPE CONSTRUCTION CONSTRUCTION BUILDING NEAREST NEAREST _ FOUNDATION��ZG/���^� LOT LINE CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMA DISTANCES: f/� ���✓ INSTALLED BY:�'�C/�>!%�i PIPE MATERIAL" I LOT SLOPE: REMARKS: ,r9- �r-n�lc� ✓�sr3i��rio�ci Form No. EQ -031 u012ra DISTANCE FROM: SEPTIC s -� SEEPAGE TANK •' SYSTEM DIAGRAM OF SYSTEM n n e� ,lk, 3' R h DATAPPROVED G.A.A.B. �'o� REATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 3ewwue DISPOSAL SYSTEM — APPLICATION AND PERMIT NAME OF APPLICANT • 11 T K INSTALLATION LOCATION LEGAL DESCRIPTION c INSTALLATION OF: SEPTIC TANK — TYPE AND SIZE OF FACILITY TO BE SERVED PHONE -34-�' a/'5-4�Z SEEPAGE PIT V ` 1X?DRAIN FIELD , OTHER 4J FINANCED THROUGH TO BE INSTALLED BY SOIL TEST RESULTS .l� NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE e-DTYPE r_S-" ^� SEEPAGE AREA SIZE /6 rx l �_ TYPE C'.e..rn�'�` MINIMUM DISTANCES, REQUIREMENTS -1 FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT v — i DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL / --2 SEPTIC TANK SEEPAGE PIT DRAIN FIELD TO NEAREST LOT LINE. $- J WELL TO SEPTIC TANK �jdy `. SEEPAGE PIT `� a'5E- 5 DRAIN FIELD ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK d 1 SEEPAGE PIT DRAIN FIELD SEPTIC TANK, SEEPAGE PIT �N FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REG D NG INSTALLATION. G.A.A.S. OR LICENSED DESIGNER 1 CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCH DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATE 15 1 1 APPLICANT'S SIGNATURE✓ FORM NO. EQ -016 AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE Gravelly Sand (SP) Silt Some Sand (ML) Silt, Some Sand Trace Clay (ML -CH) rj Sand, Trace Silt (SP) rASilty Sands (SP -SM) 1 0C2 0.0' 2.0'- 6.0' 13.0' �! 20.0' T.D. No [dater Table T.H. 2 5-8-74 0.0' o. s Gravelly Sand 0.5' Silty Sands (SM) Z 5� 6.0' D 0 Sand, Some Silt (SP -SM) % 15.0' ° a•' Gravelly Sand a'• w/Some Silt (SP) J 30.0' T.D. o�F.o No Water Table DON GRAY PROPERTY CC Engineering & Geologiccl Consultants Inc. LOG OF TEST BORINGS 4 ANCHORAGE FAIRBANKS ALASKA JUNEAU Anchorage Alaska �- S — SCAI_[ 11i-51 DWN BY .�RJ CHKD BY WED PROJ• NO. 462025 DWG No. A-01 Dar.= - _------------- _ Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcell.D. 017-063-05 HAA# N 2 1. GENERAL INFORMATION Expiration Date: 10 Complete legal description SOUTH HILLS SUBDIVISION; LOT 2 BLOCK 2 -- Location (site address or directions) 7246 HILLSIDE WAY * ACHORAGE, AK. 99516 Current Property owner(s) DON AND BARBARA GRAY Day phone 345-1009 Mailing address 7246 HILLSIDE WAY * ACHORAGE, AK, 99516 - Lending agency Mailing address Real Estate Agent Mailing address NIEL THOMAS W/ COLDWELL BANKER Day phone Day phone 265-9105 2525 "C" STREET * ANCHORAGE AK 99503 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual On-site l� Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, Ltd. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, Ltd. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for bedrooms. Disapproved. 337-6179 Date 04 X Conditional approval for 4 bedrooms, with the fllowing stipulations: At the time of title transfer, the new property owner shall sign the attached maintenance agreement which shall be returned to this office before and unconditional approval is issued. Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Manitenance Agreements t/ Supplemental Engineer's Reort Other By: / CeP!L (�f Original Certificate Date: -7 (Rev. 12101) Municipality of Ancn'Qrage a _. Development Seryl ces,Department �yunw Building Safety Division $fi9TY On -Site Water & WastdWater Program ' e epff,(rsse tse�yst _ iri. a er " Tgal New depth _in. .Q. ox '96"8 P nch rage AK 89519 6650 16-6V Absorption rate >_ �,u, xewxaY ' t*��anci�orage ak us KIMIC''Vninwni . 4 g.p.m. - g.p.m.NOT SO � NLW KeeunS kF7-7 /r'a11J rvi. �yunw e epff,(rsse tse�yst _ iri. a er " Tgal New depth _in. iTf1"depth _ in, " .„ Absorption rate >_ g.p.d. KIMIC''Vninwni M, d'alf6nse Ac High water alarm level at in. Cycles tested— Meets alarm & circuit requirements? line On On tank Water main field an in..... .......... date._ Waiver Fee $ Date of Payment Receipt Number J fr a 53 Pr T,