Loading...
HomeMy WebLinkAboutSOUTH HILLS BLK 3 LT 2South Hills Block 3 Lot 2 #017-072-24 Inspection Rep)D i-1-12.doc Municipality of Anchorage Community Development Department Page 1 of 4 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP121280 PID Number: 017-072-24 ❑ New ❑✓ Upgrade Name: William & Dolores Duty ABSORPTION FIELD ❑ Deep Trench EI Shallow Trench 2 Bed ❑✓ Mound Address 7700 Our Own Lane ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 0.7 GPD/SF 0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade +.5 Ft. Gravel depth beneath pipe 0.5Ft. Subdivision Block Lot South Hills 3 2 Fill added above original grade 3.0 Ft. Gravel length 41 Ft. Township Range Section Gravel vddth 23Ft. Beds: Number of Lines 4 Distance between lines 5Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 943 Fe N/A N/AFt. Well 100.7 111.0 111.0 N/A 83.9 TANK ❑ Septic p S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1250Gal. Surface Water 103.2 105.0 105.0 N/A Material Number of compartments Lot Line 65.2 16.5 65.2 N/A Steel 2 NA Foundation 12.3 15.8 12.3 N/A LIFT STATION Manufacturer Capacity Curtain Drain N/A N/A N/A N/A Anchorage Tank/ Orenco 250 Gal. Remarks Pump on level at 43 in. Pump off level at 40 in. High water alar at 45 in. Pump make and model P005 Electrical Inspections performed by Installer PIPE MATERIAL Housetotank 3034 Tankto drainfeld 3034 Anderson Construction Dralnfield 3034 CO/MT 3034 Inspector Pannone Engineering Services BENCHMARK (Assumed elevation) 100ft Inspection ,r dates: 1 11/13/12 2nd 11/13/12 Location and description V 11/13/12 a 11/14/12 Corner of House COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Date #erti` �atnope� LApprve(Date al 4 Inspection Rep)D i-1-12.doc NOTE: EXPOSED BOTTOM OF BED IS NOT TO BE DRIVEN ON. \ OUR OWN LANE i '77 10' UTILITY ES MT g 3 WELL (E) > II Lo w WELL (E) w �3 \ J 102.0` I _� 115.8 TH-1 NOTES: PANNONE ENG SVC LLCof a\\ Date RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 C� •"" gS+ll� 6/17/2013 PHONE (907) 272-8218 FAX (907) 272-8211 /�Cppy+� Scale TH .. .... SOUTH HILLS, BLOCK 3, LOT 2 .... ... . P.I.D. NO n-02-24 • teven •R. •Penna-ne• / WILLIAM 8c DOLORES DUTY / PERMIT N0. .•. CE 8149 OSP121280 7700 OUR OWN LANE tt+cys,• PLAN ANCHORAGE, AK 99516 1�'�'•••---- Sheet ll\� owss 2 OF 4 A • 4BB M1 FC 28.5 � C1 21.7 HOES (E) T1 20.7 26.6 T2 - 19.3 LS A M2� M1 VI\ 39.7 M2 M1 M3 M3 IV, C1 s ... �1 .5 1 67.7 ' �w ,.:: T1 ABANDONED COLLAPSED 1250g TANK T2 -�- AND LIFT STATION (E) PER CODE NEW DRAIN FIELD , (BY REMOVAL).., `, M4 REMOVED ALL BIOMATTED MATERIAL INSTALLED NEW 1500g S.T.E.P. TANK /TH-2 WITHIN 10' OF NEW BED. 3 103.2 TH-1984 (LEE REID) 41 LF x 23'W x 0.5'ED, O.O'TD W/ 2' SAND, AND t3' MOA TYPE II FILL \ AS NECESSARY TO REPLACE BIOMATTED MATERIAL AND CREATE SEPARATION ` --`DISTANCE TO GROUND WATER. REEK /5 2 v� NOTES: PANNONE ENG SVC LLCof a\\ Date RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 C� •"" gS+ll� 6/17/2013 PHONE (907) 272-8218 FAX (907) 272-8211 /�Cppy+� Scale TH .. .... SOUTH HILLS, BLOCK 3, LOT 2 .... ... . P.I.D. NO n-02-24 • teven •R. •Penna-ne• / WILLIAM 8c DOLORES DUTY / PERMIT N0. .•. CE 8149 OSP121280 7700 OUR OWN LANE tt+cys,• PLAN ANCHORAGE, AK 99516 1�'�'•••---- Sheet ll\� owss 2 OF 4 A B M1 FC 28.5 0.0 C1 21.7 29.5 T1 20.7 26.6 T2 15.9 19.3 LS 15.2 16.4 M1 18.4 39.7 M2 21.8 30.9 M3 51.6 64.0 M4 1 9.4 1 67.7 NOTES: PANNONE ENG SVC LLCof a\\ Date RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 C� •"" gS+ll� 6/17/2013 PHONE (907) 272-8218 FAX (907) 272-8211 /�Cppy+� Scale TH .. .... SOUTH HILLS, BLOCK 3, LOT 2 .... ... . P.I.D. NO n-02-24 • teven •R. •Penna-ne• / WILLIAM 8c DOLORES DUTY / PERMIT N0. .•. CE 8149 OSP121280 7700 OUR OWN LANE tt+cys,• PLAN ANCHORAGE, AK 99516 1�'�'•••---- Sheet ll\� owss 2 OF 4 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK WAS IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. 3. SCOPE OF WORK: INSTALLED NEW 1500g S.T.E.P. TANK AND SOIL ABSORPTION SYSTEM. 4. GROUNDWATER WAS OBSERVED AT A DEPTH OF 6.0' AS EVIDENCED BY THE SOIL TEST HOLE, AN APPARENT WATER TABLE WAS NOT OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 6.0 FEET BELOW EXISTING GRADE. OL 9]4 —3.5 GM I —7'5 BOH t3' MOA NPE II TO REPLACE' REMOVED BIOMATTED MATERIAL AND CREATE SEPARATION DISTANCE TO GROUND WATER 'o 1500g S.T.E.P. TANK (P) DESIGN PARAMETERS PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 4 (600 gpd) TANK SIZE: 1500g S.T.E.P. PERC RATE = <1 MPI SOIL RATING: 0.7 GPD/SF AREA ROD: 858 SF SYS. TYPE: BED 0.5' E.D. RIGID INSULATION FILTER FABRIC 1Ya" 0 DRAIN PIPE W/ X" HOLES 8" O.C. DRAW ROCK 6" ABOVE PIPE INV TOPSOIL AND DRAIN ROCK VEGETATED 102.4 TH-1984 90.5' LEE REID) —1.0 OL 9].4 ML —5.0 GW SECTION _7.5 BOH $9/24/1984 w� m� Fz �z RIGID INSULATION i o i FILTER FABRIC o o DRAIN ROCK 6" ABOVE PIPE INV o r ¢ t84" 0 DRAIN PIPE W/HOLES 18" O.C. _102.4 10 99.4- " 97.4 97.4 TRENCH SEE DESIGN PROFILE LEGEND W WATER LINE/ WELL RADIUS — SS — NEW SEPTIC USED: REPLACED EXISTING 41 LF X 23' WIDE, 0.5' E.D., 0.0' TD 2' SAND TOTAL AREA: 943 SF ABBREVIATIONS CU COPPER DIP DUCTILE IRON PIPE TH TEST HOLE FC FOUNDATION CLEAN OUT T# TANK CLEAN OUT NO. C# CLEAN OUT NO. M# MONITOR TUBE NO. R. 1. RIGID INSULATION DCO DOUBLE CLEAN OUT DV DIVERTER VALVE FS FLOW SPLITTER BFG BELOW FINISH GRADE OG ORIGINAL GRADE FG FINISH GRADE TS&V TOPSOIL AND VEGETATE NOTES: PAMONE ENG SVC, UCs'�' OF q� \kDate RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 .... '•...4,9 1 6/17/2013 � ' PHONE (907) 272-8218 FAX (907) 272-8211 /�g�p �y�+ Scale *; 4911.1 *,� NTS �... .....:.. P.I.D. NO SOUTH HILLS, BLOCK 3, LOT 2 „% 017-072-24WILLIAM & DOLORES DUTY j••Ste've'n R. Pannone % PERMIT NO. �r. !] '. CE 8149 % 7700 OUR OWN LANE OSP121280{mss, r DESIGN DETAILS ANCHORAGE, AK 99516 1� �A� ••••• Pr sheet 3 OF 4 TEST HOLE 2 ORGANICS 1 CLOCK TIME WATER NET TIME LEVEL READING NET DROP FILL/ <1 MPI 2 SEPTIC 2 Scale NTS MATERIAL! SOUTH HILLS, BLOCK 3, LOT 2... WILLIAM & DOLORES DUTY 7700 OUR OWN LANE ANCHORAGE, AK 99516 3 BIOMAT 4 4 SOILS LOG Sheet eOF 4 ML SILT 6 GW 6— s RAVEL- GRAVEL- LOOSE BOH 7 s 9 10 11 12 13 14 15 16 17 18 19 DATE PERFORMED: 11/13/12 SOILS LOG - PERCOLATION TEST SLOPE X TH 10' UTILITY E MT D_ SITE PLANLLJT L TH-1 s 4BR HOUSE (E) TH-2 WAS GROUND WATER ENCOUNTERED? N IF YES, AT WHAT DEPTH? -- DEPTH TO WATER AFTER MONITORING? - DATE: --/--/-- SLOPE TH X READING DATE CLOCK TIME WATER NET TIME LEVEL READING NET DROP 1 11/13/12 <1 MPI 1/;;/2013 RECORD DRAWING 2 Scale NTS SOUTH HILLS, BLOCK 3, LOT 2... WILLIAM & DOLORES DUTY 7700 OUR OWN LANE ANCHORAGE, AK 99516 3 P.I.D. NO n-672-24 PERMIT NO. OSPI21280 4 SOILS LOG Sheet eOF 4 5 6 PEROLATION RATE <1 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 5 FT AND 6 FT COMMENTS: Test hole excavated by ANDERSON CONSTRUCTION, Prec hole was presoaked After the hole was ore -soaked a readine was unable to be taken due to the Dercolation rate. PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. NOTES: PANNONE ENG SVC, LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 ���� r of kNkk i '��•'•' '•'9S (� /ry�P ?y+� tri �.... ... .... / Steven R. Pannone / (�+P '• CE 8149 �� ,� i'P 1/;;/2013 RECORD DRAWING Scale NTS SOUTH HILLS, BLOCK 3, LOT 2... WILLIAM & DOLORES DUTY 7700 OUR OWN LANE ANCHORAGE, AK 99516 P.I.D. NO n-672-24 PERMIT NO. OSPI21280 SOILS LOG Sheet eOF 4 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP121280 Tax Code Number: 01707224000 Work Type: Septic Upgrade Permit Effective Dates: September 13, 2012 to September 13, 2013 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: SOUTH HILLS Site Legal Address: SOUTH HILLS BLK 3 LT 2 G:2940 Owner/Address: DUTY WILLIAM D & DOLORES K 7700 OUR OWN LN ANCHORAGE AK 995163821 Site Mailing Address: 7700 OUR OWN LN, Anchorage Lot Size in Sq Ft: 46790 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. AMC 15.65.060.8.3 Received Issued By: I?— MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program Mayor Dan Sullivan ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. (2 072- u/ Propertyowner(s) IJI1LIy44d-0CyLo2cS fa)j j� Day phone Mailing address 11020 WK b,d V Site address 7700 0JK OuYy Lg ir�z' Legal description (Sub'd., Block & Lot) ffwT/l#JLLS,&ax 3, 1or2 Legal description (Township, Range & Section) Lot Size _710 Sq. Ft. Number of Bedrooms THIS APPLICATION IS FOR: THIS APPLICATION IS AN: (® all that apply) Initial ElAbsorption Field Septic Tank Upgrade UL Tank ❑ Renewal ElHolding Privy ❑ Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized Permit/Rush Fees: $536 - Date 53bDate of Payment: 'y1Rg11D Receipt Number: 0a5_0 / -p Permit No. 616PI2/a2 Waiver Fees: Date of Payment: Receipt Number: Waiver No. GABuilding\On SiteTorms\Client FormsTermit App_010411.doc (Rev. 1/11) Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve0paneneak.com September 13, 2012 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: South Hills, Block 3, Lot 2 Septic System Permit Upgrade Request Ladies and Gentlemen: I am writing to request a permit to upgrade the septic system be issued for this property. The proposed systems will serve an existing four (4) bedroom house. Currently the lot is developed. The bed will be removed and replaced. The existing collapsed 12508 septic tank and lift station will be abandoned per code, and a new 1500g S.T.E.P. tank will be installed. This lot is served by a private well that is located over 100 feet from this system. The surrounding lots are also served by private wells. There are no wells within 100 feet of this system. 1. Soils. A single test hole was excavated by Pannone Engineering Services in August of 2012, and the ground water monitored for seven days. Groundwater was observed at 6.0' in the test hole monitor tube after the seven day monitoring period. Bedrock was not encountered in the test hole. It is my opinion, based on the results of the percolation tests and overall soils appearance; an application rate of 0.7 gallons/day/square feet should be used for conventional wastewater system. 2. Soil Absorption System Design. a. See Sheet 2 of the design package. Due to the space constraints a bed width of greater than 15' is necessary. Installing contractor is experienced and will use appropriate equipment to prevent driving on bed. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The topography slopes from northeast to southwest at approximately 8%-10% in the area of the proposed drain field. There are no steep slopes in the area. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 Page 2 of 2 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On -Site Department, the note will be removed and 'Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of the surrounding or existing lots. There are no wells or septic systems within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Attachments -Soils Log -Septic System Design Mailing: P.0, Box 1.00217, Anchorage, AK 99510-0217 Physical: 332 East Manor Ave, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX. (907) 272-8211 EXPOSED BOTTOM 0FBED |SNOT TO8EDRIVEN ON. OUR OWN LANE HOUSE 108.0 13.9 ss ss vv� ABANDON COLLAPSED 1250g TANK (E) DRAIN FIELD (E) (P) AND LIFT STATION (E) PER CODE TH 1984 REMOVE ALL BIOMATTED MATERIAL INSTALL 1 500g S.T.E.P. TANK (P) (LEE REID) WITHIN 10' OF NEW BED. 100.0 105.0 AS NECESSARY TO REPLACE BIOMATTED MATERIAL AND CREATE SEPARATION DISTANCE TO GROUND WATER. MEAN ANNUAL FLOOD LEVEL NOTES: PAMONE ENG SVC, IM Date FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 ...... 9/13/12 PHONE (907) 272-8218 FAX (907) 272-8211 10v SOUTH HILLS, BLOCK 3, LOT 2 017-072-24 WILLIAM & DOLORES DUTY St Pa no.* PERMIT NO. 7700 OUR OWN LANE 1p, 1. 8149 OSP121280 PLAN ANCHORAGE, AK 99516 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. 3. SCOPE OF WORK: INSTALL NEW 1500g S.T.E.P. TANK AND SOIL ABSORPTION SYSTEM. 4. GROUNDWATER WAS OBSERVED AT A DEPTH OF 6.0' AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 6.0 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. H-3.5 Y -7.5 BOH 33' MOA TYP REMOVED BIOM AND CREATE SEPAR TO 'o '9 z i L�l Fa v E 15008 S.T.E.P. TANK (P) DESIGN PARAMETERS PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 4 (600 gpd) TANK SIZE: 1500g S.T.E.P. PERC RATE = <1 MPI SOIL RATING: 0.7 GPD/SF AREA ROD: 858 SF SYS. TYPE: BED 0.5' E.D. R FABRIC 0 DRAIN PIPE W/ M" HOLES O.C. IN ROCK V ABOVE PIPE INV IN ROCK SECTION mz z� =8 o� z PROFILE ML GW -7.5 9/24/1984 TRENCH SEE DEIGN LEGEND W WATER LINE/ WELL RADIUS — SS — NEW SEPTIC USE: REPLACE EXISTING 41 LF X 23' WIDE, 0.5' E.D., 0.0' TD 2' SAND TOTAL AREA: 943 SF WITCURAWIVIIISPIN CU mz DIP z� TH i8 FABRIC o t J ROCK 6" ABOVE PIPE INV zo F 0 DRAIN PIPE W/1§" HOLE �na O.C. 11 TRENCH SEE DEIGN LEGEND W WATER LINE/ WELL RADIUS — SS — NEW SEPTIC USE: REPLACE EXISTING 41 LF X 23' WIDE, 0.5' E.D., 0.0' TD 2' SAND TOTAL AREA: 943 SF WITCURAWIVIIISPIN CU COPPER DIP DUCTILE IRON PIPE TH TEST HOLE FC FOUNDATION CLEAN OUT T# TANK CLEAN OUT NO. C# CLEAN OUT NO. M# MONITOR TUBE NO. R.I. RIGID INSULATION DCO DOUBLE CLEAN OUT DV DIVERTER VALVE FS FLOW SPLITTER BFG BELOW FINISH GRADE OG ORIGINAL GRADE FG FINISH GRADE TS&V TOPSOIL AND VEGETATE NOTES: PANNONE ENG SVC LLC '��"""N� Date P.O. BOX 100217 ANCHORAGE, AK 99510 r C� °F A�Asli� 9/13/12 FOR CONSTRUCTION � .� PHONE (907) 272-8218 FAX (907) 272-8211 /�g�py�� Scale NTS �.... ... :.. P. 1. NO SOUTH HILLS, BLOCK 3, LOT 2 •......... % on -072-24 WILLIAM & DOLORES DUTY Steven Pannone PERMIT N0. PF;CE 8149 j 7700 OUR OWN LANE �� �s • .. OSP121280 DESIGN DETAILS ANCHORAGE, AK 99516 Sheet 2 OF 3 TEST HOLE 1 SOILS LOG - PERCOLATION TEST SITE PLAN OR ORGANICS SLOPE 10' UTILITY El MT ORGANIC SILT 3 OL MIXTURE WELL (E) 3 3 4 J p E- 5 TH-1 GM SILTY GRAVEL \� 6 XTH 46R \ HOUSE I, 8 BOH \ \ w 10 W-� W �1 TH-1984 12 (LEE REID) ` 13 WAS GROUND WATER SLOPE 14 ENCOUNTERED? Y 15 IF YES, AT WHAT TH 16 DEPTH? -6.0-' X 17 DEPTH TO WATER AFTER MONITORING? -6.0'- 18 DATE: 8/23/12 19 DATE PERFORMED: 8116/12 PEROLATION RATE <1 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 3.5 FT AND 4.5 FT COMMENTS: Test hole excavated by A+ HOME SEVICES. Prec hole was presoaked. After the hole was pre-soaked a reading was unable to be taken due to the percolation rate. PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. NOTES: PAM 7�7� LLC .���� FOR CONSTRUCTION Pl1L\1\Ol\i'i ENG SVC, LLti. .�". QF A(\\`� D9/13/12 P.O. BOX 102954 ANCHORAGE, AK 99510 r �� q@ �� PHONE (907) 272-8218 FAX (907) 272-8211 j g�p 9��� s.a. W: NTS ....... ... ....* P.I.D. NO SOUTH HILLS, BLOCK 3, LOT 2 .....- •, •••••• 17-072-24 Steven R. Pannone WILLIAM & DOLORES DUTY PERMIT NO. 9� : CE 8149 � OSPI21280 SOILS LOG ANCHORAGE, OAK 99516 WN LANE�till�\0.`=`� Sheet 3 READING DATE CLOCK TIME NATER NET TIME LEVEL NET DROP READING 1 8!16/12 <t MPI 2 3 4 5 6 �^ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE NEW L L 1 A ❑ UPGRADE MAILING ADDRESS 7 ®C3 OUR 0 W&I L4 N L LEGAL DESCRIPTION Lot '�-50U_t14iLLS56C . 3 LOCATION NO. OF BE ROOMS B �2 tl L� UY DISTANCE TO: Well tQ� Absorption arear loo Dwelling �. P�7 NO. PER'W686 o®6•Z h QManufacturer - A) C HOR 4 GC Mater' No. of co rtments yI- Li . capacity in gallons IF HOMEMADE: Inside length Width Liquid depth Y DISTANCE TO: Well Dwelling PERMIT NO. JAZ 2 Z F Manufacturer Material Liquid capacity in gallons 0 w= DISTANCE TO: Well Foundation Nearest lot line PERMIT NO. j LL Z No. of lines Length of each line Total length of lines Trench width Distance between lines 1=- Z inches F Top of tile to finish grade Material beneath tile Total effective absorption area inches Length l n Width t Depth S s PERM6 O T tj w� Type of crib Crib diameter. Crib depth Total effective absorption area p, I T' N DISTANCE T0: Well �' Building foundation Nearest lot line 1 1 J Class a . Depth Driller Distance to lot line PERMIT NO. wRII` 71 DISTANCE TO: Building foundation Sewer line Septic tank 1 O3 t Absorption area(s) P ® f 1 C7 OTHER PIPE MATERIALS 03o34 SOIL TEST RATING I IS c� INSTALLER GEAG-E E - q REMARKS FJG. i > •'PAN 4 ' GJAJ d r FAillAic PLiGep 1AD 13ED A3 DEsifveo 57-84 J 11 '/V!; ZCI D 4V.' 611--u CA'r,:r C' a v L Fr Z. 2r If APPROVED DATE LEGAL %/1ib1g¢ G 14, LLS t11N R A W 5 cc T 72-013 (Rev. 3/78) J m H._J 1%,A I C:'::IL: P` if-­-* L_ Xi _T"V t �' >t . PA (. ' V-1 CJ Fes" rN C-ti ✓E r DE!"'AR.TMEN'T' OF' HEEAL:TH AND ENVIRONMENTAL PROTE:MT:I ON 825 1.._ S'T RE•-: ET a ANCIFIORAGE., AK 99501: 264-4720 C] ih A — - ::,, I "T"' E�: �; � � W. i1��11� �� fix.,,: 1 �1 f 1._.1 � `EE 1 ":1{1�1; .1 . � .. ' PERM TT NO e 841-0862 t862 ENGINEERED DES I GN10t i)A'1`E": Tf'tGIfEI},; D"),/10/04 AF'F'LICANT­ a WI1 I.._IAM DUTY J ADDRESS,, 7.700 OUR OWN LANE ANCHORAGE v Ar05:!.6., CONTACT PHONE -3*45­4547 LEC:it-?!.... l7ESCRIF­ SUDDIVIISION. SOUTH HILLS LOT. ^ BLOCK- _ SECTION: = TOWNSHIP: 1,11\1 RANGE: .3W LOT SIZE. 1.25A (SO. FT. OR ACRESD 'I: certify that.. I- :1: Rm familiar with the requirements for bri-site sewers :,ant`! VJEa.!..1.'s as set. forth by the Municip ality of Anchorage (MOA) and the State cif' Alaska. 2. T will install, the system in accordance with all. MOA c:o(Jes and regulations., and in compliance with the design criteria of this permit.. I will. adhere to all MOA and State of Alaska requirements for the set back distances from any existing well., wastewater dit:posal system or putblic sewerage yst..E:?tit on this or any adjacent. or nearby lot.. IF" A 1__IF7 STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, I`HEN (:I.) AN ELECTRICAL PERMIT AND INSPECTION MUST RE OBTAINED; (`.?) AS--I"� IJ i LTS WIL._I.- NOT BE APPROVED WITI...!OUT AN L:LI...:CTRTCAL INGF'ECT:I:ON RI-71ORT-,, AND (1-1r) Tl-IE" ELECTRICAL WORK ,MUciT BE. DONE BY A LICENSED ELECTRICTAN. fi.T.fihIED 1') ,,., I}ATE- .__...---.... t-PPLICf-'NTc WILLIAM DUTY I'>>,""..`UED BY DATE„ � 1 Ir 5IR 5Z � y til- w i� ji sa�7�d MUNICIPALITY OF ANCHORAGE Department �,,f\Health and Environmental,.x�rotection 825 'Street, Anchorage, AK. 501 264-4720 Permit # # # HANDWRITTEN PERMIT # # # L AND -m-SITE SEWER PERMIT Applicant: / (;,G /gMn Ti Mailing Address : r%��d Qv� aoq �it�, Location: 407- ,� Qlz .laud l��c f6o✓ Phone Number: S SC/ice Legal Description - / N - Lot Size: % Type of Soil Absorption System Is: / Trench: Drainfield: Seepage Bed:y Holding Tank: Maximum Number of Bedrooms: Soil Rating(sq.ft/br) /9J The Required Size of the.Soil Absorption System Is DEPTH 9J LENGTH 4-0 GRAVEL DEPTH G WIDTH The.length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE / a GALLONS # # Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. ' # # # TWO(2) INSPECTIONS ARE REQUIRED # # # Backfilling of any system without final inspection.and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 3 I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more tha 3 bedroo Signed: Issued by: Applicant iS o,�.G/ vi�t o2 0 Date: ir�s� lc�ea� SWP/024 (1/81) 7C /v2 S X /•,S / � J' o�'l Gbf'o.- J�€1�1 �/ `� 9 TO / ! S w1 FROM ¢a.nCyvr�//Y�//.��a i..v. niv�Tah€'l'aiT�".a�C�S�4u#+43Y -k SUBJECT! r g 13//x`° *3 0v% !/`s ! DATE I- MESSAtirE REPLY Redlrm9 4S 471 Poly Pak (50 sets) 4P471 SEND PARTS 1 AND 3 WITH CARBON INTACT -PART 3 WILL BE RETURNED WITH REPLY DATE SOILS LOG ' MUNICIPALITY OF ANCHORAGE a� DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST r PERFORMED FOR: LEGAL DESCRIPTION: 2 �{ w�Q�� rou ,r 3 [y,, �e� 4 t ,, f� ars ukk- 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMENTS PERFORMED BY: 72-008 (6/79) WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? DATE PERFORMED: n a t S L O P % E Z Reading.,Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE TEST RUIN BETWEEN FT AND oz�r! e-trt L'jyd, MON s�=oa CERTIFIED BY: (minutes/inch) __ FT DA ~1 SOILS LOG' MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION ❑ PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 264.4720 1SOILS LOG — PERCOLATION TEST PERFORMED FOR: �t `I Mm I/j Lot PERFORMED: .Y� (�� r� I� / LEGAL DESCRIPTION: sootk I-�(�S Lot Z' 8),ck-3 SLOPE SITE PLAN IF EIT I &L- &rjNhlL Sty' -1 1 ( P5 S ENCOUNTERED? ` L 2 O ML(k 3 t r� E DEPTH? 4 o rL e( 5 C-iv� grR�e) 6 ® 6 6t. ty 100V l 7 . r 8 9 10- 11 12 13- 314151617 14- 15- 16- 17 81920 18- 19- 20 COMMENTS Soy` WAS GROUND WATER ( P5 S ENCOUNTERED? ` L Depth to Water O P IF YES, AT WHAT t r� E DEPTH? o rL e( ZN ■o c U1 NEENNEEMEN Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE (minutes/inch) TEST RUN BETWEEN FT AND FT 3(% v: S ✓ally d `^_ -19bt:1 PERFORMED BY:�a<t� MDA S`r O`( o11/ CERTIFIED BY: 72-008 (6/79) /�° Z/*/7 �o ,s1,144 U*14-v GREAOIER ANCHORAGE AREA BORO'v,�H DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TUDOR ROAD POUCH 6-650 ANCHORAGE, ALASKA 99502 TELEPHONE 279-8686 10P 7 SEWAGE DISPOSAL SYSTEM — APPjdC/ATION AND PE NAME OF APPLICANT INSTALLATION LOCATION LEGAL DESCRIPTION C !' e v MAILING Z' h; Z LJ PERMIT NO. � 9 INSTALLATION OF: SEPTIC TANK�,/ SEEPAGE PIT DRAIN FIELD , OTHER TYPE AND SIZE OF FACILITY TO BE SERVED i,> FINANCED THROUGH SOIL TEST RESULTS COMPLETION DATE ANTICIPATED TO BE INSTALLED BY E NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE MINIMUM DISTANCES, REQUIREMENTS / FOUNDATION TO SEPTIC TANK �_ FOUNDATION TO SEEPAGE PIT ze'/ DRAIN FIELD SEEPAGE AREA SIZE SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK f , SEEPAGE PIT ` DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK `� R , SEEPAGE PIT DRAIN FIELD ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK SEEPAGE PIT - DRAIN FIELD P J / SEPTIC TANK, '� / � SEEPAGE PIT 00 DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. 4 HEALTH A THORITY OR LICENSED DESIGNER TYPE DIAGRAM OF SYSTEM CERTIFY ��%f fNC N6 THAT THE 1 CERTIFY THAT 1 AM FAMILIAR WITH/THE REQUIREMATS OF GREATER A HORAGE AREA BOROUGH O D ANCE NO. 28.68 A THAT THE ABOVE DESCRIBED %Y�iSTEM jS IN ACCORDANCE WITH SAID CODE. 4 DATE `- ( PLICANT'S SIGNATURE 'i L,eceab,er 4-0, 1 J7 Mr. Jit,,I PickneY : t. Rt. At box 400" Anehur-a(,Te, Alaska 9Q-507 SuLj,c-ct: Installation of on-site sewakC systeli, Lot Clock '3t "uUtIl dills Subt;iVisioll. Dear Otr. Pickney: ot', February 2�, l972, you ubtiAined a perv;,i t to instal I, all un -site sewage systLi, on,block 3 Lot South fills SUbqivisiorl which is still outstanin in uur'files.'... In our telephone conversation edrTier this wotith you stated that a cessi)ool was still being use", oil the property. j Si rets cesst)ools are illeg,�l wit;jin thi! Borou�ih, this office Will allow you until July 15, 1973 to Put in d septic tank and seepage pit (u'r'drainfi�,I,) vjjjich will conforti, to Borough specifications. To j first 9 this./you First need a stils test Laken by a 3eolo5ical firl'...' Upol, receipt of tile soils test, we -all estirjjjte the pit size needed for the existing building on the property and you will then be able to co,,,Iplete installation. final inspection aiiust be iijade on the installation before backfilling is Completed. F4ilurL- to copply with 5orough re�--,ulatiuns %tay result in court action to be taken aainst you. Any questions may be directed to this offiee. Sincerely, D.A. Darr Levi vironoental Control Officer 1 m Hefty Drilling S.R.A. Box 1553 H AnchorageAlasks, .. {j WELL LOG wii Lam Duty Lot 2 Blk. 3 Date.Drilleds 6-9-84 South Hills''Subd, Static Water Level 5 gpm feet Gallons Per Minute 30+ Artesian Draw Down N/A feet Total Feet of Caesing,,53 ICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION NOV 2 2984 Tvne Material Drilleds RECEIVED 0 feet to 20' Sandi gravel II 20 feet to 27. Surface water 22 feet to 50 clay (Prev) gravel I 5n feet to 53 gravel w/water to - - to I Hefty Drilling S.R.A. Box 1553 H AnchorageAlasks, .. {j MUNICIPALITY OF ANCHORAGE ox Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 017-072-24 1. GENERAL INFORMATION Expiration Date: l ` / — 2--Z-- Complete legal description SOUTH HILLS BLOCK 3, LOT 2 Location (site address) 7700 OUR OWN LANE, ANCHORAGE, AK 99516 Current property owner(s) WILLIAM & DOLORES DUTY Day phone Mailing address 7700 OUR OWN LANE, ANCHORAGE, AK 99516 Real estate agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ® Private Septic Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5 Waiver Fee $ Date of Payment l (7 a Date of Payment Receipt Number 1 �q r 51 Receipt Number COSA # 0 sc a Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Address 13030 SUES WAY, ANCHORAGE, AK 99516 Engineer's Printed Name CURTIS HUFFMAN, PE Date 7/16/22 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & FWCS 6. DSD SIGNATURE System #1 Approved for _q_ bedrooms System #2 Approved for bedrooms Disapproved �A l l • .& i . _ ....•.. .... ...V�.1.': . Curtis Huffman CE 128991 c�s�Fq' . ,7/16/22. •���,��`�� 1,\,DPROFESSION�� r Conditional approval for bedrooms, with the following stipulations: QP��TY 0)z.. IX ON-SITP WATER AKin m By: � N11__ Original Certificate Date: — l The Municipality of Anchorage Development Services bivision (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other Legal Description: SOUTH HILLS BLK 3 LT 2 Parcel ID: 017-072-24 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ® Well log is filed with Onsite (or attached) Date drilled 6/9/84 Total depth 53 ft Cased to 53 ft ® Sanitary seal is functioning correctly ® Wires are properly protected Casing height (above ground) 24 in. Date of flow test for COSA 7/15/22 Static water level at beginning of test ARTESIAN 4 ft. Well production at time of test 6+ qpm Comments Structure served by this system Water storage tank volume NA gallons Well disinfected for coliform test? ❑ Yes ® No ® Coliform bacteria is Negative Nitrate 1.06 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ® Arsenic less than MRL (ND) Collected by FES Date of Sample 7/15/22 B. TANK DATA C. LIFT STATION Age of tank(s) 10 years ® Required maintenance completed Tank type/material S.T.E.P / STEEL Age of lift station 10 years Measured operating fluid level in septic tank * Lift station material STEEL ® Standpipes/foundation cleanout per record drawing Comments: *MOA STEP MAINTENANCE Date of pumping 7/13/22 D. ABSORPTION FIELD DATA Which system tested (date installed) 11/13/12 Adequacy test date 7/15/22 ® ALL standpipes present per record drawing Results ID Pass For 4 bedrooms Total measured depth from grade 4.1 ft (max) Fluid depth prior to test 0 in (DRY/MOIST) Measured depth to pipe invert from grade _ft (min) Water added 600 gal ® N/A — pressurized field New depth 0 in. (DRY/MOIST) ® Monitor tubes go to bottom of effective. If not, state depth into effective MOA IR SHOWS 0.5'ED Elapsed time 180 min ® Code -required soil cover over field Final fluid depth 0 in (DRY/MOIST) ❑ System presoaked Absorption rate 600 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N date of test) Ifes, enter date Gallons introduced gallons y Comments/Deficiencies: ALL 4 MTS WERE DRY/MOIST FROM START TO ADEQUACY TEST END Nirs E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ® Yes if No ft Community Sewer Manhole/Cleanout > 100' ® Yes if No ft ® Yes if No Neighboring Tank > 100' ® Yes if No ft Private Sewer/Septic Line > 25' ® Yes if No Absorption Field on Lot > 100' ® Yes if No ft Holding Tank > 100' ® Yes if No Neighboring Absorption Fields > 100' Surface Water > 100' ® Yes Animal Containment > 50' ® Yes if No ® Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ®Yes if No ft ® Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ® Yes if No ft Surface Water > 100' ft ft ft ft Mil ® Yes if No ft Property Line > 5' ® Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ® Yes if No ft Private Wells > 100' ® Yes if No _ Water Main > 10' ® Yes if No ft Community Wells > 200' ® Yes if No _ Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ® Yes if No ft If absorption field is under driveway comment below Property Line > 10' ® Yes if No _ ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' ® Yes if No _ ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATIONi�k�1 1 certify that l have determined through field inspections and review ,,!,�Q� • • ` ` of Municipal records that the above systems are in conformance with /' aj •; i� I MOA COSA guidelines in effect on this date. : ` • Curtis Huffman �¢� �'F; •, CE 128991 .*,4 i ��l<c • . 7/22/22.. • •�.s ��1�� pROFESS10Nt�.aAW M ft OUR OWN LANE 8503S CD 0 L0 to _ S89057'05"W 152.53 10' Utility Easement I Well W Shed 'i > _N 'a Wood fence (typ) > I 2.0 OH 4.5- C6 24.0 Y + 1 1/2 Story o Frame House N deck I� 'I 38. 48.0 ° shed N_ �p deck c0 ° I M Lot 3 N oO ° V_ it M`Manhole I Lot 1 SCALE: V= 50' Sauna a ( O Chain link fence Septic vent (typ) J ( 00 CD ( 00 EO I C:) OF • q�qs 1 A. oa I �'?' 49th • • � �d� Z Shed I j E 00 . ai ®i ':'Elizabeth L. ftotka . R 00 (uj �` -�F • • 8036 - LS , • •Jew® F ..r OT 2 W 0FESSI OtAp,\_ r AS -BUILT NO CORNERS SET THIS DATE I hereby certify that I have performed a Mortgagee's inspection in accordance with ASPLS Standards of the following described property: LOT Z BLOCK 3 _ SOUTH HILLS SUBDIVISION Anchorage Recording Precinct, Alaska, and that the S85052110"Eimprovements situated thereon are within the property lines O 152.90] and do not overlap or encroach on the property lying to adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and O that there are no roadways, transmission lines or other OLD RABBIT visible easements on said property except as indicated - CREEK ROAD hereon. --- Dated at Anchorage, Alaska `-- — -- this 12th day of AUGUST , 2022. EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED FRED WALATKA &ASSOCIATES, L.L.C. PLAT ARE NOT SHOWN HEREON BEEngineers and Surveyors UNLESS OTHERWISE NOTED. FB 22-2, pg 61-62 907-248-1666 This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered, the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product. MUNICIPALITY OF ANCHORAGE ' DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE 1. General Information Application Date i (a) Legal Description (include lot, block, subdivision, section, township, range) Location (address or directions) (b) Applicants Name to; j. (_ ;; Applicants Address "7'7 hone - Home. < ; `' business (c) Applicant is (check one) Lending Institution ; Owner/builder Buyer � ; Other E_:�j (explain); .� (d) Lending Institution Address (e) Real Estate Co. & Agent Address Telephone (f) Mail t(h��e(� HAA to the following address: 5 �- - 2. Type of Residence Single -Family Multi -Family Number of Bedrooms L1. 3. Water Supply IndividualWell L� . Community Other (describe) Public E Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. Sewage Disposal Onsite EEJ Public [-::I Community E::l Holding Tank El Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. [Page 1 of 2] Jk as. 9 5. Engineering Firm Providing Inspections, Tests, File Search, Data and Information As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that, based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regula- tions in effect on the date of this inspection. Name of Firm %� LSC �,� Telephone i - 4r-,'; Address1 % ��• %JF 44`4$�p Date.,� ��7 !„/ J.j `� ��A• "*4to No.'a�7;ti��gnt,`T�`aT"�•�e 0,0 e � r� �f s • t (ENGINEER SEAL) ir.00 "O.” a gas *Cos.. «f v C. Reid, Jr. G� 6. DHEP Approval ®�-09� o%2 Q•51UE.¢�•� A Approved for bedrooms By - Approved 'yL Disapproved Conditional Terms of Conditional Approval CAUTION THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION (DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES ANDI THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE- MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK. (DHEP SEAL) RR4/ej/D18 [Page 2 of 2] 7-19-84 MUNICIPALITY OF ANCHORAGE - DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION ap MUNICIPALITY OF ANCHORAGE (MOA) NOV 2 11984 HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 RECEIVED A. WELL DATA Legal Description: Lot Z_ ,t ry _3 �a�fiM le'LLs tt/lb i( �Gy1 S'"�z 3 Well Classification r/?t . V/AtC If A, B, or, C. D.E.C. Approved(Y/N) .,U Well Log PresentDate Completed Yield30tGP.,A-1 Total Depth 53 Cased to 53 � Depth of Grouting Static Water Level ARTE,51� N Pump Set At t 1 /c1LNOcc�.ai Casing Height Above Ground 2` Sanitary Seal on Casing iI)_ Electrical Wiring in Conduit CYyN) Depression Around Wellhead (Y Separation Distances from Well: To Septic/Holding Tank on Lot On Adjoining Lots � /u} To Nearest Edge of Absorption Field on Lot !/a ; on Adjoining Lots > oo To Nearest Public Sewer. Line To Nearest Public Sewer Cleanout/Manhole A)/Y-A- To Nearest Sewer Service Line on Lot �rrs Water Sample Collected By ; Dat 57/fif Water Sample Test Results 5 17 ®S f;'4C-T'C'x Y Comments PAR a2aLe_ Ln 6 A AJ' -1 6 5901tT� vt eTc //12�as oti� c ons B. SEPTIC/HOLDING TANK DATA 6 Date Installed 111j1,fp�4 Size 1, ZS -0 No. of Compartments Standpipes CVN) Air -tight Caps fYN) Foundation Cleanout YXt�7) Depression over Tank (Y& Date Last Pumped A✓t.&I Pumping/Maintenance Contract on File (YM)A)/)4,for Holding Tank High -Water Alarm (YM) A� A� Temporary Holding Tank Permit (Y ),o Separation Distances from Septic/Holding Tank: To Water -Supply Well 103 ° To Building Foundation r To Property Line ) 7 ` To Disposal Field 1S' To Water Main/Service Line, To Stream, Pond, Lake, or Major Drainage Course - Comments tri �cfe riea �y fi� ✓� su Receipt #Q�{1 b 7 Date Paid: Amount: yet y� (Page 1 of 21 2-15-84 - < 2 13 3 /4,-u5 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata J5p'�� Type of System Design d3& n Date Installed Length of Field Lf,/ Width of Field 23Depth of Field .S' Gravel Bed Thickness ,5 Square Feet of Absorption Area 9 f-3 a� Standpipes Present N) Depression over Field (Y& Date of Last Adequacy Test ,y/14 Results of Last Adequacy 'lest Separation Distance from Absorption Field: To Water -Supply Wall //$ ' To Property Line /l / To Building Foundation /S To Existing or Abandoned System on Lot On Adjoining Lots 1,) 3o To Water Main/Service Line AJ/to, To Cutbank(if present) ata To Stream/Pond/Lake/or Major Drainage Course jc)5- r To Driveway, Parking Area, or Vehicle Storage Area i.) 'Z 8' Comments 1NFO,eA4A1-i0AJ' pL,,w �5%sU•� r I.�PP/( �=�iL�? Ni suet -�t Gam D. LIFT STATION Date Installed (I/l letsq Dimansions 36" o A, Size in Gallons - /6 7 15&//yo_d. Manhole/Access CO/N) "Pump On" Level at 4Z'"Pump Off" Level at High Water Alarm Level at 4(4 Vent Y ) Tested for Pumping Cycles during Adequacy Test. Meets MOA Electrical Code (_N) Cormnts I .SEE ATIAC H t L"LFC rR04L A L_ I/USPc-r_r: ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or corformvd to all MOA HAA Guidelines in effect on the date of this inspection. OF Signed lo, Date jy�P••••HM••000%i���� CompaXV[R $ MOA NO. SThi -02�{ ERS+y�, KB1/d5/s [Page 2 of 21 t 2-15-84 Soils Rating in Absorption`Strata Type of System Design Date Installed Length of, Field Width of Field Depth of Field Gravel Bed Thickness Square Feet of Absorption Area Standpipes Present (Y/N) Depression ovek%'dld (Y/N). Date of Last Adequacy Test Results 'of:LastrAdequacy;;Zbst Separation Distanee',frcm Absorption Field: To Water -Supply Well'" To Property Line To Building•Foundation To Existing or Abandoned System on Lot on Adjoining Lots To Water Main/Service Line' To Cutbank(if present) To Stream/Pond/Lake/cr Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area ComTents D. LIFT STATION i Date Installed Dimensions Size in Gallons Manhole/Access "pump on" Level at, Z%� "Pump Off" Level at High Water Alarm Level at',- qC09 `l Vent (YM) Tested for Pumping Cycles during Adequacy Test. Meets MDA Electrical CodesfY ), ; Caaments i i * Check Permitted Bedroom Rating Against HAA Request ** j I, certify that I have checked, verified, or conformed to all MOA HAA Guidelines in effect ENGINEERS SEAL 2-15-84 ALASKA bUInOMPTAL COnTnOL SRUS, 1110. engineering & Enuironmenral Studies SPECIFICATIONS FOR SUBSURFACE ELEVATED BED ALTERNATIVE WASTE WATER TREATMENT SYSTEM — SOUTH HILLS SUBDIVISION, BLOCK 3 — LOT 2 1.0 GENERAL 1.1 THE DRAWINGS, SHEETS 1 THRU 4, SHALL BE A PART OF THIS SP E CIFIC A TION. 1.2 ALL MATERIALS AND WORKMANSHIP SHALL MEET THE REQUIREMENTS OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERMIT. 1.3 ALL EXCAVATIONS AND DEPTHS ARE ADVISORY AND ARE TO BE VERIFIED OR MODIFIED IN THE FIELD BY THE ENGINEER. 1.4 ITIS THE RESPONSIBILITY OF THE OWNER TO OBTAIN ALL NECESSARY PERMITS. OR EASEMENTS. 2.0 THE LIFT STATION 2.1 THE STOCK MATERIAL FOR THE LIFT STATION SHALL BE EITHER GALVANIZED STEEL (ASTM A-4444-76), OR ALUMINUM CULVERT, CAPABLE OF BURIAL TO 10 FT. 2.2 THE 36" DIAMETER PIPE FOR THE LIFT STATION SHALL HAVE A WELDED WATER TIGHT BOTTOM OF THE SAME THICKNESS AND COMPOSITION AS THE CULVERT. 2.3 ALL PENETRATIONS OF THE LIFT STATION SHALL BE WELDED AND WATER TIGHT. ALL WELDS SHALL BE CLEANED OF SLAG. WELDS ON GALVANIZED STEEL WILL BE SPRAYED WITH ZINC RICH PAINT OR COATED WITH BITUMASTIC. 2.4 THE TOP CAP SHALL BE RAIN TIGHT AND SECURELY FASTENED WITH SCREWS. A TWO INCH LAYER OF POLYURETHANE FOAM SHALL BE GLUED TO THE INSIDE OF THE TOP CAP. 2.5 ALL ELECTRICAL FITTINGS AND CONNECTIONS IN THE LIFT STATION SHALL MEET THE REQUIREMENTS FOR A WATER TIGHT SER VICE. 2.6 THERE SHALL BE A HIGH LEVEL ALARM, PEABODY BARNES 6147 OR EQUAL SET AT THE LEVEL OF THE SOIL PIPE FROM THE SEPTIC TANK. THE BUZZER SHALL BE LOCATED NEAR THE ELECTRICAL CONTROL PANEL OR IN A LOCATION DESIGNATED BY THE HOMEOWNER. 2.7 THE SUMP PUMP SHALL BE CAPABLE OF DELIVERING 10 GPM AT A HEAD OF 20 FEET. 2.8 PROVIDE A CALDER COUPLING AT THE CONNECTION OF THE 4" SOLID PVC INFLUENT PIPE AND 4" STEEL NIPPLE. 2.9 THE PUMP SHALL BE CONTROLLED BY A DIFFERENTIAL MERCURY FLOAT SWITCH, ADJUSTED TO ALLOW A TWO FOOT SPAN BETWEEN 'ON' AND 'OFF', AS SHOWN IN THE DRAWING. ALL RELAYS AND ELECTRICAL CONTACTS SHOULD BE LOCATED OUTSIDE THE CHAMBER TO PROTECT THEM FROM CORROSION, PREFERRABLY IN A DRY LOCATION WITHIN THE HOME. 2.10 COAT THE INTERIOR OF THE CHAMBER WITH BITUMASIC PAINT OR TAR TO APROXIMATELY 3.5 FEET ABOVE THE BOTTOM. 1200 West 33rd Auenue, Suite 13 • Anchorage, Alaska 99503 • (907) 561-5040 2.11 MOA BUILDING CODES: WHEN LIFT STATIONS ARE INSTALLED WITHIN THE MUNICIPALITY, AN ELECTRICAL PERMIT AND INSPECTION ARE REQUIRED. IN AREAS NOT COVERED BY MOA BUILDING CODES, THE SYSTEM SHALL BE INSPECTED BY A LICENSED ELECTRICIAN TO INSURE THAT THE ELECTRICAL INSTALLATION IS IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS. 3.0 SEEPAGE BED 3.1 THE GRAVEL FOR THE BED SHALL BE SCREENED TO THE SIZES INDIC A TED. 3.2 THE SAND SHALL HAVE AN EFFECTIVE SIZE OF 0.4 TO 0.6 MM AND A UNIFORMITY COEFFICIENT OF NOT MORE THAN 4. 3.3 THE BERM AROUND THE SEEPAGE BED SHALL BE CONSTRUCTED OF IMPERMEABLE MATERIAL, AND ON A SLOPE OF 1 FOOT VERTICAL PER 3 FOOT HORIZONTAL. 3.4 THE BOTTOM OF THE EXCAVATION SHALL BE RAKED WITH THE BACKHOE BLADE TO INSURE THAT THE BOTTOM HAS NOT BEEN COMPACTED DURING EXCAVATION. THE BOTTOM ELEVATION SHALL BE PLUS OR MINUS 2". 3.5 TWO OBSERVATION PIPES SHALL BE PLACED AS SHOWN IN THE DRAWINGS. THEY SHALL BE RIGID PVC, ASTM 3033 D-3034. THE SECTION SHOWN WITH HOLES MAY BE EITHER DRILLED 0.5" HOLES C 6INCH CENTERS ON OPPOSITE SIDES OF THE PIPE OR A SECTION OF PERFORATED SEWER PIPE MAY BE CLAMPED TO THE SOLID SECTION WITH A NO HUB COUPLING OR SOLVENT JOINT. A RUBBER RAIN -CAP (JIMCAP OR EQUAL) SHALL BE PLACED ON THE TOP OF THE PIPE. 3.6 THE INSULATION REQUIRED SHALL BE DOW EXTRUDED BLUE STYROFOAM INSULATION BOARD OF THE THICKNESS SHOWN ON THE DR A WINGS. 3.7 THE TOP AND SIDES OF THE BED SHALL BE PLANTED WITH A WHITE CLOVER AND RED FESCUE MIX. ALASKA ENVIRONMENTAL CONTROL SERVI(?'�, INC. 1200 West 33rd Avenue Suite B ANCHORAGE, ALASKA 99503 Phone 561-5040 JOB 6'/7&� W f SHEET N0. OF CALCULATED BY 'K 2!: '/ DATE CHECKED BY DATE_ u SCAIF MOW 2041.,li�ve%w I.x. G�, *a 01411 /0 3 7 ALASKA ENVIRONMENTAL CONTROL SERVIQ�, INC. 1200 West 33rd Avenur Suite B ANCHORAGE, ALASKA 99503 Phone 561-5040 JOB SHEET NO,/j�, OF. CALCULATED BY VIA= DATE- & -o r ?y CHECKED BY DATE ALASKA ENVIRONMENTAL CONTROL SERVIO`--'�, INC. 1200 West 33rd Avenues Suite B ANCHORAGE, ALASKA 99503 Phone 561.5040 JOB--�C�c...iF`l "t SHEET NO. OF CALCULATED BY V A��y DATE CHECKED BY DATE 0204.! M s Inc., GMu Mw. 01471 0 Z/&/ r ALASKA ENVIRONMENTAL " ' _- CONTROL SERVICES, INC. SHEET NO. OF 1200 West 33rd Ave` Suite $ IROS 8/30/84 ANCHORAGE, ALAb:.A 99503 REVISED BY •si DATE Phone 561.5040 CHECKED BY DATE L /FT STATION DETAIL GALVANIZED OR PAINTED I%4"D/A PULL-PIPE CONNECTED TO , METAL COVER NEMA 4 2" URETHANE FOAM P/TL ESS ADAPTER FOR ENCLOSURE GLUED TO COVER PUMP REMOVAL GROUND LEVEL POWER AND PUMP i l CONTROL LINES / -4 DIA STEEL PIPE it 1� PITLESS ADAPTER j ItCONDU/T _ PUMP CONTROL I =2" COUPL ING PUMP 4' MIN 2"SOLID P. E OR AB :P-OWER TO ABSORPTION AREA FIL LET WELD _.: AROUND PAPE HEAT TAPE _ GALVANIZED STEEL ,%'(ASTM A-4444-761 4 "DIA SOLID PVC PIPE ALARM OR ALUMINUM CUL VERT CORD FROM SEPTIC TANK -T ALARM LEVEL s„ "ON " — — PUMP LEVEL CALDER COUPLING % CLAMP DIFFERENTIAL MERCURY FLOAT SWITCH \ t� o 0 PUMP TOFF"LEVEL _ PUMP s1_. Pv -,--,- v GALVANIZED OR INSIDE OF PITSHALL RE COATED W/TH PAINTED STEEL PLAT 91TUM/NOUS PAINT U4_7AR 36" .. e 3 � a r 1A0.CfAH �K. 6gOl Ya 1071