HomeMy WebLinkAboutSOUTH HILLS BLK 6 LT 16A MUNICIPALITY OF ANCHORAGE He~ h and Environmental Prot¢ ~.on Fourth Floor West 825 L Street Anchorage, Alaska 99501 279-2511, x 224, 225 ...... ~N-sP~CHON REPORT ON-SI'~E SEWACE DI,.gPOSAL SYST~:M NAM~."T~_'_L). ....... MAILING ADDRESS ~: ~'~ .~O~ ~ .~_~ .... PHONE __. SEP flC TANK: ,,q E)I!HANC[-"~/~) IVlANUFACIUHER~ M&IEI]IAL COMPARTMENTS NUMBER OF ........... .~ INSIf)[~ L. ENGllt .......... INSIDE w DY t QUll) DJ'PIN ..... LI()LJID CAPAC TY~_GA_.ONS. TI,LE [)RAIN FIELD: 0..,,~ N[:Ai~[tS r [01 LINE oFTOTALLINELENGTH ..... DISTANCE BE~WE[N LINIS ..... I liEN(Il WI[)IIt~IN, TOFAL [FI:'ECTIV[ SEEPAGE Class: __ Depth: Well Distance To: Lot Line Bldg: Sewer Line: Pipe ~aterials: # of Bedrooms: Installer: O~UC~:~ Remarks: Log .... Crib Rings/CRIB SIZE: DIAME1E. t ....... )EPI It _ _ DISTANCE FROM: WELL 1OTAL EFFECTIVE June 20, 1977 R & M NO. 751178 Mr. Ted Gifford 4546 Business Park Blvd. Anchorage, Alaska Subject: Soil Investigation for Sanitary Sewer System, Lot 16 Block 6, South Hills Subdivision, Anchorage, Alaska Dear Mr. Gifford: At your request of June 16, 1977, we conducted a subsurface soils investigation at the proposed location of the sanitary sewer system on the subject lot. The investigation complied with those procedures required by the Municipality of Anchorage Department of Health and Environmental Protection. This investigation, which was accomplished on June 16, 1977, consisted of a test hole drilled to a depth of 16 feet below the existing ground surface. The test hole was sited according to the instructions furnished by Mr. William Bredeson and its location is shown in attached Drawing A-01. Drilling was accomplished with a rotary drill rig using continuous flight solid-stem auger with an outside diameter of 6 inches. A sample was taken at the depth shown on the soils log in Drawing A-O1. The sample will be held in storage at our lab for approximately six months. In addition, all material brought to the surface by the augers was continuously monitored by an experienced engineering geologist. The topography at the drilling site is generally steeply-sloping to the North. At the time of the investigation the site had original vegetation consisting of spruce and alders. The top of the test hole was located at original ground surface. The soils encountered in the bore hole are shown in the test hole log in Drawing A-01. The symbols used in Drawing A-01 are explained in Drawings B-01 and B-02. This log displays specific conditions encountered at the test location. However, subsurface conditions may vary in other partss of the lot without any apparent surficial evidence of the change. Groundwater was not encountered in the test hole. Bedrock was not encountered. At the time the hole was drilled seasonal frost was not present. Based on the visual classification of the soil and the requirements set forth by the Municipality of Anchorage, a percolation test was not necessary within the test hole on the subject lot. June 20, 1977 Mr. Gilford Page -2- We appreciate this opportunity to be of service to you. Please contact us if you have any questions concerning this letter or we can be of additional service. Very truly yours, R & M CONSULTANTS, INC. M. Ayres Staff Geologist Jim McCaslin Brown, PhD. Bead, Earth Science Department JMA:JMS/sl Attachments: Drawings A-01, B-01 and B-02 iILLSIDE DR[ YE 2 1 TH EAST 132 AVE Lot 16, Block 6, South Hills Subd. Anchorage, AK Not To Scale Distances shown are approximate and have not been measured by surveying methods. SCALE ,See aboveJ~ TEST HOLE LOG Scale: 1"=3' O' ORGANIC SILT WITH SOME SAND Dark brown 2.0' GRAVELLY SA~D WITH SOME SILT (SM) ~ r Ol~ln 3.5 ' SANDY GRAVEL w/ TRACE TO SOME SILT (GP) Occassional cobbles 5.0' GRAV~EL WITH SOME SMD, TRACE SILT (GW) Many cobbles, A ® Boulder at 15' Refusal on boulder 16.0 T.D. Groundwater was not encountered. This log depicts subsurface soils observed within the test hole at the location shown. See Drawings B-01 and B-02 for explanation of symbols. LOCATION ~KETCE AND : TEST ttO~E LOG ! ~ TED GIFFORD ]2940 IPROd'NO 751178 [DWG. NO. A-01 ___J MUN,O,PAL,TY OE,  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTI~iCiPALiT¥ OF ANCHORAGE 025 L Street - Anchorage, Alaska 99501 DEPT. OF h-ALTH & ENVIRONMENTAL p~O fECTION ENVIRONMENTAL ENGINEERING DIVISION .-- Telephone 264-4720 NOV 2 & 1978 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEW~~ DIRECTIONS: Complete aH parts on page 1, Incomplete requests will not be processed, Please allow ten 110) days for processinfi. MAILI DDRESS ' PHONE MAILING ADDRESS 4. REALTOR/AGENT PHONE 6. TYPE OF RESIDENCE · ~ SINGLE FAMILY MULTIPLE FAMILY WATER S PPLY 7. ~ INDIVIDUAL* t'_J COMMUNITY [] PUBLIC UTI LITY NUMBER OF BEDROOMS [] One [] Four [] Other__ [] Two [] Five ~ Three [] Six * ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior to t~at ~t% give well depth(attach I o g if ava i lab,e.g__) ** I f individual/on-site, give installation date([~_l~l _. If system is over two (2) years old an adequa~ test is requh-ed 8. SEWAGE DISPOSAL SYSTEM  INDIVIDUAL/ON-SITE*~ PUBLIC UTILITY by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72~010(3/78) ~2~(~ L~ THIS SIDE FOR OFFICIAL USE ONLY INSPECTION APPOINTMENTS TIME TIME DATE DATE DATE RECEIVED TIME DATE 1. TYPE OF RESIDENCE F~.] SINGLE FAMILY Ii~] MULTIPLE FAMILY 2. WATER SIJpPLY F~] INDIVIDUAL EJ COMMUNITY [--] PUBLIC UTILITY Connection Verified 3. SL:WAGE DISPOSAL SYSTEM ~_~ INDIVIDUAL/ON -SITE F] PUB[_IC UTILITY NUMBER OF BEDROOMS [~] ONE L] TWO [~ THREE [-_'] FIVE; ~ [] L~J FOUR [~] SIX PERMIT NUMBER OTHER DEPTH OF WELL DATE DRILLED LOG RECEIVED [_~Septic-r~k or lC] ~o d 19 Trak ~~ Size:.~ _~ If Tank is'ho,~:E~ SOILS RATING give dinlensions: ~%--( TYPE OF TANK MANUEACTURE~. ,~ TOTA~ ABSORPTION AREA MATERIAL. [ ~~ 4. DISTANCES Septic/HoMing Tank WEE LTO: Abso, ption Area to nearest L~t Line PERMIT NUMBER DATE INSTALLED 5. COMMENTS ~J-~APPROVED FOR __'.~__ ...... BEDROOMS [~] CONDITIONAL APPFtOVAL (letter must accompany cci tificate) [~] I)ISAPPROVED ~ 72-010 {Rev. 3/78) 2NV7 /1AO~JVHo~ I ~ ~1,~$07£ OJ oem×e~ (£0~-8L.)