HomeMy WebLinkAboutSOUTH LAKEWOOD HILLS #1 BLK 6 LT 7016 161 I Municipality of Anchorage ttBMITTA On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 2 ON-SITE WASTEWATER INSPECTION REPORT NOV 0 6 2017 Permit Number OSP171282 PID Number: 015-151-26 Dwelling: C Single Family (SF) ❑ Duplex(D) ❑ Multiple (SF and/or D) Project: ❑ New ii Upgrade Name WELL FARGO ABSORPTION FIELD Address ❑� Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 0.6 GPD/SF 12 Ft LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 4.0 Ft. 8.0 Ft. SOUTH LAKEWOOD HILLS #1 B6 LOT 7 Fill added above original grade Gravel length Township Range Section 1-2' Ft. 65' Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 2.0' Ft. Ft. To, Septic 'Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist.between trenches From l Tank Field Tank Line 1040 Ft2 Ft. Well 100'+ 1100'+ 50'+ TANK 0Septic ElS.T.E.P. ❑ Holding ❑Other Manufacturer Capacity Surface Water 100'+ 10(Y+ ANCH TANK 1250 Gal. Material Number of compartments Lot Line 10'+ 101+ STEEL 2 NA - Foundation 10'+ 10'+ LIFT STATION Manufacturer Capacity Curtain Drain 1 UN UN Gal. Pump on level at Pump off level at High water alarm at Remarks in. in. in. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank 3034 Tank drainfito eld 3034 MIKE N ANDERSON,P,E, Draintield 3034 CO/MT3034 !Inspector MIKE N ANDERSON, P.E. BENCH MARK (Assumed elevation) 103.2 ft Ins daction tes: rt 10/30/17 2nd 11/30/17 Location and description 31a 4th GARAGE SLAB COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL 4,`,` �tamp O1= At .....,„A.. � CSS,`! Conditional Approval: Date p w'�..• • .:�f+ * :Pi 49TH r01 4 ---T • r i •.MICHAEL N. ANDERSON .a4 r e� ,C -9469 ``..� 4ru'f'f 1�•Lehr7- �'L' Approved I 4... Date 7"17 tkvi-Ruff scv��Y.-. Inspection Reporl_9-1-12.doc J . Permit No. OSP171282 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On—Site Wastewater Disposal System and/or Well Inspection Report Legal Description: SOUTH LAKEWOOD #1 BLK 6, LOT 7 PID No.: 015-151-26 MARK A B I TC01 40 73 1 C04 53 85 C 06 )( )( 9( , )( O )( )( ); Q x x xex x x x ),7 i! 1 '�I'/ 1 1 C I- - - _ I x \ x SEW 1250 STEEL TANK --x--- _ Ti/ ART \\ \V x 1 • Ix I 1CO3 \ r cot \ / " \ •I • 1 SYSTEM DECOMMISSIONED x `° 01 \ �: CO2, \\ ,$• x J - r` CO, x \ _ \ .... 1 :) IVEW,4Y C. ---- 1 1 � 1 x ` I II ( x 1 a � X x \ x \EXISTING WELL \ I 1 I \1 x7- ASBUILT I x 1 SCALE: 1"=30' I \` CO' CO2 TCO, cos C04 COS rCQ6 ���O 1711114, lz ruT ..• �� F 4��,�. „rut,I - '-u, L l'472;:".**.. ..••••Y'l .. _/—nom fABRi[ V 2r _` \"� 952 / QALLdI 't. Q y,q 'M' • STEEL TAM( 95 0 M 97 / s2_/ '\1' =.M1Ci,AEL N. ANDERSON.14 : 9Q9 / \90.9 I•%%... No. CE 9469 •'� ` •• ''� SEPTIC SECTION ./ .14/14�•r•""''''1'•' S N.T.S. )4 2,0 94, J 444 / i::��4••. �NJvn a MUNICIPALITY OF ANCHORAGE 1„ ,,,- On-Site Water &Wastewater Program Abise`t PO Box 196650 4700 Elmore Road • Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 r. <, �1 http://www.muni.orglonsite I)c.•parttuenI 4N CHO_R HVf On-Site Wastewater Disposal System Permit Permit Number: OSP171282 Effective Date: 10/2/2017 Work Type: Septic Upgrade Expiration Date: 10/2/2018 Tax Code Number: 01515126000 Site Legal Address: SOUTH LAKEWOOD HILLS #1 BLK 6 LT 7 G:2638 Site Mailing Address: 11151 WILDWOOD DR, Anchorage Owner: WELLS FARGO BANK N.A. Lot Size in Sq Ft: 31284 Design Engineer: ANDERSON CONSTRUCTION & ENGINEERING Total Bedrooms: 4 This permit is for the construction of: E Disposal Field Q Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: /lap Date: /fv„�l Issued By: U" Date: 794/7 • MUNICIPALITY OF ANCHCR051.11. Community Development Department ` Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water& Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-151-26 Property owner(s) WELLS FARGO BANK Day phone Mailing address Site address Legal description (Sub'd.. Block & Lot) SOUTH LAKEWOOD HILLS#1 BLK 6, LOT 7 Legal description (Township, Range & Section) Lot Size 31284 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade ❑X Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy PI (SF and/or D) Private Well (_J Water Storage THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. If44/44— (Signature of property owner or authorized agent) Permit/Rush Fees: 7 c"o•46 Waiver Fees: Date of Payment: �q/ASjl? Date of Payment: U Receipt Number: r /ow Receipt Number: Permit No. d5,711' Waiver No. Permit App__-.- : c Sept. 25, 2017 Municipalities of Anchorage Departments of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Fax 249-7847 Re: New Septic Permit for Conditional COSA Legal: SOUTH LAKEWOOD HILLS #1 BLK 6 LT 7 To Whom it may concern: This is a request for a septic permit on the above referenced lot the old system has failed. A test hole was excavated and found silty sands, SM, for the entire depth. The perc rate was found be 22 minutes therefore a simple deep trench was designed with an effective depth of 8 feet. No water was measured in the test hole during or after the excavation. The tank will also be replaced at the same time. The slope around the site fairly flat with no cut banks within 100 feet, see site plan. This system will not impact any of the neighboring properties due to the lot layout. This is also a conditional COSA to close the loan. Twice the excavation/engineering amount will be set into escrow for payment of the repairs, see attached email from title company. Please call me if you have any questions. Sincerely Michael N. Anderson, P.E. 4661 Natrona Anch, Ak 99516 Ph 727-8864 DESIGN CRITERIA: I MOUND OVER (TH#1) o r� GRADE 4 BDRM X 150 = 600 GPD -ORG I SOILS = 600/0.6 = 1000 GPD 1 0 FILTER FABRIC 1000 GA/16 =63' a 0 ��� •"0 PIPE (1)TRENCH SEWER ROCK 12.0' DEEP 8.0' EFFECTIVE I SM -12.0 2.0' WIDE 2.0' I 63' LONG 19 0 F i SEPTIC FIELD SECTION I I II -MICHIGAN BLVD- I- 1 I I 1 Ir" II II I I , 1 II II I 1 I 1 ' II I :i, - - - - -J I- - - - -w1 1 L II > - 1 I ___ � - - - -Q -- ` ~MACBET�tvE� - o II f _ _----- I ' II g' II I _ — _ — 11 - -,I1 _ -w`� • chi ;1 cc I u) I 1 PROPERTY LINE �7EXISTINGWELL iOOI \ / 1 0'1RADIUS I0 - - - - ` �' PROPOSED \ I �, I I .`� -�� � - \_ S DRAINAGE FIELD J ,(� ' — '�7 ' 11 ,_s., EXISTING HOUSE .'-----1--- L — III 1 I I f11 - - - -r- - - - 5 1 4-- 112TH AVE,' J b ,L1 w w ix III co J 1 III UJ III L III � � � � -Ir- III 1 - - - � - - - - l,, I \ N. Septic Design Prepared for ...�t11ts%%•_ WELLS FARGO BANK .���,� OF 44'ly.4. �. • SOUTH LAKEWOOD HILLS #1, BLOCK 6, LOT 7 = '•49 „ ,�.., Anchorage, Alaska S T" • • • r Michael N. Anderson, P.E. DATE: 9/21/2017 ♦�� '; ICHAEL N. ANDERSON:: 1 �r, •. No. 0 94 4601 NATRONA AVE DRAWN: DJR 1�` '+ ANCHORAGE, ALASKA 99516 •i ••''t •.z?•,/'�„x )•~ (907) 345-3377/FAX: (907) 345-1391 SCALE: 1"=200' t4 4M 'i".;�*� 4 • - -1 — — 1 .„--- 1 • _ • 1 )• / I I \ SEPTIC •♦ I � `• /// k I • `\� II 1 \ / 1 t I 1 / / I 1 • I r I��-�,J I f /1 tI I WELL r1 • • 1 i .l 5 1 ••t 1 1 1 • 1 11 1.1 ••'• r Ir r<1 �I 1 I // II / 1•\ 1 / _ / / / 1• ALL WELL RADIUS' / ~1_ ' / i/ •• TO BE STAKED BY // 1 PROPERTY LINE •• SURVEYOR PRIOR // �/ • TO EXCAVATION /� L11 ,/r- •� L/' ��- - — — ��/ / N 11 ' 11 M M M )1 A / — CC _ ____ _ _ .- \ l'---_ .... -.. ....+- i 1 ----— J I __ J --.r _ --- 5-6°i° PROPOSED FIELD K x _•` ✓ 1 j t v'o � `••MT I 1 -- I . •�• / fist tiUtg4 K `y`+ x `, CONTOURS �`, I /// EXISTING I \� ••� gei � �, I TYP.--.,„<:,....,♦ // HOUSEi `�\ I I /r •` 11 ; -a /'1 DCO " > L.1 /' ••• `OCO CO I 1•\ SEPTIC ••h / • // 11 pR��� P-1 4 BEDROOM HOME JI�y?• c��i1` ~ I ,1• •/ \•• X • l! I 11 mss. y 111 I w x 1250 GALLON TANK ♦•• 1 x 1 W WELL I x �\ 1 I i I f r I o I EXISTING SYSTEM l 1 x f` � x TO BE I yl 11 II II II I' 1 1' II N 'llN N )♦ MN N -L_ DECOMMISSIONED- rPROPERTY LINE A10 t Al 0 / PER UPC w Q ��EXISTING WELL • // -112TH AVE- // 100'RADIUS • / / • / / > / / / • , / / / • / / i — Septic Design Prepared for WELLS FARGO BANK =���E OF q�-4,..-4, •• ...AY-, SOUTH LAKEWOOD HILLS #1, BLOCK 6, LOT 7 :: 49T �r �� Anchorage, Alaska r r P.E. �... . .. w P Michael N. Anderson, .E. DATE: 9/21/2017 �,,0':MICHAEL N. ANDERSON, 4601 NATRONA AVE DRAWN: DJR O. No. 9 69 ;•��`i ANCHORAGE, ALASKA 99516 �1 • •., �, 414P (907) 345-3377/FAX: (907) 345-1391 SCALE: 1"=50' 444 SS:� �; • • 'Ail Municipality of Anchorage .� V....*I; _ S 89'59'00' E. 190.00 I ; aat 1.- Y ft- (13 o `t � co b 100 0 0 a 29.3 z QI o O � �T4-- SEPTIC • O I TWO STORY • O _I 14.1 WOOD FRAME Z HOME • N ( 2 8.4 WELL • o o 0 0 ( o in 30X3.38 - ( S 89'59'00" E. 190.00 cA o L -__---------------- _-_--E.__1_1. 2 t __ _ 1/ . -- - Bobby F. Burnett GRAPHIC SCALE: T Inch = 30 Feet 2941 Uarriage Drive Anchorage, Alaska 99507 (u07) 350-5541 15 0 15 30 ( Date Scale Legal Description _ — Of' A4.1110. \r 8/04/201 ( 1' - 30' If- Grid AS-BUILT Lot 7 BLOCK 6 ,kS�`� � ' SW 2638 SOUTH LAKEWOOD HILLS SUED. ;' �.4 °Y � Drawn by Field Book FIRST ADDITION f* .4 9 * N * #BFB ASB-2017 PLAT # P-611 / I hereby certify that the property described hereon has been surveyed / a by me. or at my direction, and that the improvements situated thereon . DOBBY F. BURNEPI : are within the property lines and do not overlap or encroach on the LS-5484 property lying adjacent thereto unless otherwise shown. That no + O _' 7 '� improvements on the property lying adjacent thereto encroach on the , - _ premises in question and that there are no roadwa s, trenamisBloII P��p" lines or other easements on said property except as shown. , SSIONAL t' GREA'[ . ANCHORAGE AREA BORO H Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM ~,¢z;,.,,o ,,¢~t. o¢~¢ SEPTIC TANK: D STANCE FROM WELl INSIDE LENGTH NUMBER OF MANUFACTURER -~t(,~/%~T' MATERIAL /~t~]2~L~ COMPARTMENTS / INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY~ ¢0 GALLONS. DISTANCE FROM WELL /O~)/~/- FOUNDATION ~¢ J~/~ NEAREST LOT LINE_ ~-0 /~/~ TOTALOF LINES LENGTH NUMBER OF LINES / DISTANCE BETWEEN LINES ABSORPTION AREA ~.2>¢j ~, ~ SQ. FT. LENGTH OF EACH LINE t(~ ~'*~" ! ~'-~t~_/t'/-/ ¢>t~/'~7~ DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE ///~ MATERIAL BENEATH TILE IN. ABOVE TILE TRENCH WIDTH~ IN. TOTAL EFFECTIVE IN. WELL: TYPE_ ~:,~'"A/O/g. CONSTRUCTION ~ /'7 Z2I~_/g_LE!-~ BUILDING /.j*_ NEAREST /,./~. NEAREST FOUNDATION /~ LOT LINE /¢ , SEWER LINE__ CESSPOOL , OTHER SOURCES APPROVED J/' DISAPPROVED REMARKS DEPTH ~'! ~ / DISTANCE FROM: · , SYSTEM_ DISTANCES: INSTALLED BY: ~<~-~' SEWER LINE DEPTH: PIPE MATERIAL: LOT SLOPE: DIAGRAM OF' SYSTE~ Form LQ-032 ANCHORAGE AREA BC--' tlGH (i/Ill IHI)\T~ · ~ ' Department;~3E0n;ir~;eme;ntal Quality · " Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE FROM WELL INSIDE LENGTH . MANUFACTURER ~<-~/~-- MATERIAL INSIDE WIDTH LIQUID DEPTH ,d~ NUMBEROF ~ ~ COMPARTMENTS .LIQUID CAPACITY ~ GALLONS. SEEPAGE Pit: NUMBER OF PITS __ LINING MATERIAL BUILDING FOUNDATION__ ADDITIONAL ABSORPTION DIAMETER OR WIDTH CRIB SIZE: DIAMETER NEAREST LOT LINE__.. LENGTH DEPTH DEPTH DISTANCE FROM: WELL TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) SQ. FT, TYPE ~//~ / ~/' CONSTRUCTION BUILDING NEAREST NEAREST FOUNDATION LOT LINE SEWER LINE __ DEPTH ~/ ;? DISTANCE FROM: SEPtiC -- SEEPAGE TANK /~ / SYSTEM / ~ / CESSPOOL APPROVED OTHER SOURCES DISAPPROVED DISTANCES: INSTALLED BY: f~/-~<~') pipe MATERIAL;_ LOt SlOPe: REMARKS: ~¢//'~'~<-".~-;,-~ ~-~-~.~ Form NO, EQ-031 DIAGRAM OF SYSTEM APPROVED /G'A'A'B,' zz ~-"~/:'Z-~'>.~,~_ . SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT GREATEr ANCHORAGE AREA BorOUGh DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO, INSTALLATION LOCATION LEGAL DESCRIPTION PHONE TYPE AND SIZE Of FACILITY TO bE SERVED /-/ '~ ' 4: ~F ~'/t~ COMPLETION DATE ANTICIPATED ~/~n O'/ - ,, OTHER. NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION, TANK SIZE TYPE SEEPAGE AREA SIZE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO-SI~R~4C'TANK FOUNDATION TO SEEPAGE Pit SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK ~ t SEEPAGE PIT TO NEAREST LOT L~NE. WELL TO ~,c TANK WATER MAIN TO SEPTIC TANK , DRAIN FIELD SEEPAGE PIT ALSO CONSIDER AREA WELLS. '~ -, DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVAT}ON 5 FEET INTO UNDISTURBED SOIL, 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO E~OROUGH REGULATIONS REGARDING INSTALLATION. TYPE DIAGRAM OF SYSTEM I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAle) CODE. THE ABOVE GREATER ANCHORAGE ArEA BorOUGh SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT INSTALLATION OF: SEPTIC TANK / SEEPAGE PIT ~ DRAIN FIEL FINANCED THROUGH TO BE INSTALLED BY PHONE OTHER -~/c~.,-~ ,~_~ -- NOTE= THIS PERMIT IS NOT VALID WITHOUT SOIL TEST SOILTEST RESULTS/ FINAL INSPECTION: 24 HOUR NOT~CE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION· SEPTIC TANK TO SEEPAGE Pit WALL SEPTIC TANK SEEPAGE PiT WELL TO SEPTIC TANK /~/'~--~7 / . SEEPAGE PIT. DIAGRAM OF SYSTEM WATER MAIN TO SEPTIC TANK DRAIN FIELD -. SePT]C TANK, ~' ~ ~ SEEPAge PIT TO RIVER. LaKE, STReAM. _, SEEPAGE PIT · DRAIN FIELD CAST IRON INTO AND OUT Of SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOil. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PET FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL SACKF"I LL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM ES IN ACCORDANCE WITH SAID CODE. ~/~j 4040 'B" STREET, ANCHORAGE ALASKA 99503 PHONE: 707-270.2581 25 November 1974 WO 17168 Attention: Project: Subject: Gentlemen: Custom Homes, Inc. 3430 Hooper Circle Anchorage, Alaska Mr. Clyde Hass Lot 7, Blk 6, South Lakewood Hills Subd. Subsurface Investigation Transmitted herein are the results of the subsurface investigation performed on the above property on November 22, 19~4. The test pit was excavated by others. The logging and sampling was p~erformed by Mr. Bruce Kenworthy, technician of our staff. The soils were visually classifed in ~he field in accordance with sheets 1 [hrough 3, following the text. This field classification was verified by visual review of samples based on the same criteria, in the laboratory. The test hole was logged as indicated on Table A, soil description. Summary Bottom of Test Pit: Frost Line: Free Water Line: 12 feet 6 inches None observed Sample Depth Type of Sample 1 2'-'6' 2 .6'-8' 3 8'-12' Grab Grab Grab Remarks: 1. 2 3 Test pit located 40 feet east of Northeast Corner of existing house. Elevation: Existing ground Date of Exploration: 22 Nov. 1974 Mr. Clyde Haas PaL,.e 2 2,5 November 1974 WC~ 17168 The seepage area required per bedroom by soil type (per the Great(~r Anchorag, Area Borough) is as follows: Soil Type (Unified Classification) Seepage Area Required ML SM SP SW GM GW 275 ft.2/bedroom 250 ft.2/bedroom 150 ft.2/bedroom 125 ft.2/bedroom 225 ft.2~bedroom 85 ft.2, bedroom Soils reqmring greater than 250 ft.2/bedroom are not allowed in seepage pit area calculations (per the Greater Anchorage Area Borough) . The .seepage area required at depth can be expressed as follows: Depth Unified Soils Seepage Area Feet Classification Required 0.5-2.0 ML 2.0-8.0 GW 8.0-12.0 GM 275 ft.2/bedroom 85 ft.2/bedroom 225 ft;2,bedroom Enclosed are some excerpts from Statd and Borough ordinances which may be of value to you. For further restrictions, particularly with reference to location of the seepage pit, we call your attention ~o the Greater Anchorage Area Borough Ordinance 28-68. If there should be any questions on the above please contac~ our office. Ver.y truly yours, ALASKA TESTLAB ~K~n~n;th W. Bleds~e~, FA[C~---~ Laboratory Superintendent Approved'~"i . ~ ' /~____~ Laboratory Manager KWB: mm Enclosure Test Pit No. 1 Depth in Feet ' From To 0.0 0.5 0,5 2.0 2.0 8.0 8.0 12'.0 Bottom of Test Pit: Frost Line: Free Water Level: TABLE A Elevation: Exist. Grnd. Soil Description W.©. tI17168 ;,akewood Iii)Is L7, B6 F-4, Peat, P ~;, brown, soft, wet. F-4, Sandy Silt, ML , reddish tan, wet, sOft, no'n plastic. NFS, Sandy Gravel , GW, tan! damp, medium to high density; · many cobbles, to 6" (sharp to subrounded) . F-l, Silty Sandy Gravel, G~, tan, damp, medium to high density to high density, many cobbles, to 6", sharp. 12 ft. 6" (inches) None Sample Deptl~ 1 2'-6' 2 6'-8' 3 8'-12' Type of Dry Blows / 6" M% Sam~)le Strength Group ........ Grab ........ Grab ........ Grab MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete a~l pa~ts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. I PROPERTY OWNER PHONE James W. Lambert & Bernice Lambert 344-5533 MAILING ADDRESS unknown PROPERTY RESIDENT (If different from above) PHONE ll2th Avenue & Wildwood Drive 2. BUYER PHONE Orville I. & Jean A. Benge' MAILING ADDRESS 825 N. Bunn, Anchorage, Alaska 3. LENDING INSTITUTION I PHONE Coast Mortgage Co. I 279-0665 MAI LING ADD R ESS P.O. Box 1200, Anchorage, Alaska 99510 4. REAL~FOR/AGENT PHONE Tanner Magowan-Curt Carley 274-2521 MAI LING ADDR ESS 5. LEGAL DESCRIPTION Lot 7, Block 6 South Lakewood Hills STREET LOCATION ll2th Avenue & Wildwood Drive 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] One ~ Four [] Other__ ~ SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY [] Three [] Six 7. WATER SUPPLY ~ INDIVIDUAL* * ATTACH WELL LOG. A weli log is required for all wells drilled [] COMMUNITY since June 1975. For wells drilled prior to that date, give well [] PUBLIC UTI L[TY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM [~ INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY 1974 If individual/on-site, give installation date If system is over two (2) years 9Id an adequacy test is required by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72~010(3/78) ,{ O? THIS SIDE FOR OFFICIAL USE ONL ' DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE I NSPECTO R INSPECTOR I NSP ECTOR DIRECTIONS: 1. TYPE-OF RESIDENCE NUMBER OF BEDROOMS [~ SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO ~ FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY [~/~ INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILI~ED [] PUBLIC UTI LITY Connection Verified LOG RECEIVED 3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER I~ II N DI VI DUAL/ON -SITE DATE INSTALLED E~PUBLIC UTILITY Connection Verified INSTALLER []Septic Tank or []Holding Tank Size: If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES Septic/Holding Tank Absorption Area Sewer Line I Nearest Lot Line WELL TO: Absorption Area to nearest Lot Line 5. COMMENTS [~APPROVED FOR ~/ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) E: D~SAPPROVED DATE B~ ~Tit'.~ ~'~ ~ ~ 2/ fl /I / ~/~ LEGAL DESCRIPTION ~'~ ~ Z ~~ ~ 5~ ~~ /~ 72-010 (Rev, 3/78) May 25, 1978 R&M No. 851525 James and Bernice Lambert SRA Box 22L Anchorage, Alaska 99507 Attention: Curt Carly Subject: Adequacy Test on Existing Sanitary Sewer System; Lot 7, Block 6, 8outh Lakewood Hills 8ubdiv±slon, Anchorage, Alaska Dear Mr. Lambert: At your request of May 22, 1978, we conducted a test of the septic system on the above described property. During the test the liquid level in the septic tank was monitored as water was added to the system. table: The measurements are summarized in the following Liquid Level Below Top Total Gallons Time of Standpipe Added 1:10 10.2 0 1:15 10.2 25 1:21 10.1 50 1:30 10.1 100 1:40 10.1 150 1:45 10.1 200 2:00 10.2 200 The meter used during the test was a Rockwell 5/8" standard water meter which had previously been Calibrated by R&M Consultants, Inc. If the 4 bedroom residence on the property is to house 8 people, the average load on the system can be expected to be 600 gallons per day or .42 gallons per minute. During the test, the system accepted 200 gallons in 50 minutes. This indicates an average effluent acceptance rate of approximately 4 gallons per minute at the time of the test. May 25, 1978 James and Bernie Lambert Page -2~ Because the house on the lot is occupied, we assume that the leach field was at its normal degree of saturation. We can therefore conclude that the system is disposing of effluent at an adequate rate for a 4 bedroom resi- dence. We appreciate this opportunity tO be of service to you. you have any 9uestions concerning this test or if we service. Please contact us if can be of additional Very truly yours, R&M CONSULTANTS, INC. Staff Geologist Jim McCaslin Brown, Ph.D. Project Manager JMB/kah GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received Time of Inspection Date of Insgection / REQUEST FOR APPROVAL OF ~I"NDIVI,DUALC~SEWER & WATER FACILITIES FOR CONVENTIONAL ~l,'~ ?Approval requested by: C1ycl~ ~aas '?"-!/i~']'i'Mailing Address: $~20 Hooper Circle ' 21!' Property Owner: · ~,~ s-'~' Ma i 1 ing Address: ~", ~' Legal Description: Phone: Phone: Lot 7, Block 6, S. Lakewood Hills Subdivision Wildwood/Rockridge Location: ,5. Type of facility to be inspected Single Family No. of bedrooms 6. Well Data: ~ ,, ~ nd~¥~dual {: ',/:?:A. Type , ,~.. i?D?Construction :i/!"'~. ."'Sewage Disposal System: , , A. Inst~lled ~i::~.?iii.:,-.-~.i:i,'C~' Septic Tank: ~]/ 'iD? Seepage Pit: ~ [E. Disposal Field: -' '~ 8.-~ Di ~tances: Installer B. Depth D. Bacterial Analysis Satisfactory 1. Size 1. Absorption Area Total length of lines 2. Manufacturer 2. Material - .,,,A.,Well to: SePtic tank ?,... :~ Nearest lot line B. Foundation to septic tank , Absorption area , Other contamination , Absorption area , Sewer Lines - C. Absorption area to nearest lot line EQ-034 (1/74) Page 1 of two pages Page 2 of two pages - Rem',est for Approval of Individual ~.~-'~er & Water Facilities Legal Description Lot 7, Block 6, Lakewood Hills Subdivision )r0yed' · ~. ~u~,~Z~YDisapproved Date AugUst"5; ~,97_5 - Approval ~¥alid for one year from date signed i;~:-i-ii--:? ~: ,- ~reater Anchorage ^rea Borough, Department of [nvironmental Quality .' ~'.~i:': DIA~RA~ OF S¥SI'[M I certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and wa~er facilities and these facilities are operating satisfactorily. SIGNED Date July 25, 1975 gRe//k r ANCHORAGE AREA OUGH 3330 C STREET, Mr. Clyde Haas 3430 Hooper Circle Anchorage, AK 99502 SUBJECT: Lot 7 Block 6 South Lakewood Hills Subdivision. Dear Mr. Haas: ......... ..:...;S.~::... Thi.s office has to date not yet approvea the sewer system on the subject lot. Since verbal notification of the deficien ....... -,~, · · cies has apparently not promoted action, written notice is - ~ :'""." now being given. W,ith five (5) days of receipt of this notice.~he following items are to be corrected: \/T) Move septic tank (s) so the tank well di ~/ce ~s a minimum of 100 feet. ~/-~ ~ ~, Pr.Ovl?e.proper air-tight caps on all cleanout ~ pipes ]nc/uaing the'six inch sump. 0~-- - Seal hole around wires from well casing. In - :'., .--' ,/~ddition, all bare wires must be properly insulated ':" '"~ Vt~o prevent accidental shock. OI/-. '/~'i:'' You w~'ll need an inspection for all three items listed above. The inspection and approval must be included in the five day -~ warning' period. This office will take legal steps to insure compliance if '' '~'~' necessary. Since the house has oeen occupied on a temporary approval basis since December, we feel the five day dead- ::':? line is justified. 4040' "B" STREET, ANCHORAGE, ALASKA 09503 PHONE: 907-279-2581 July 15, 1975 W.O. 917416 Custom Homes, Inc. 3430 Hooper Circle Anchorage, AlasKa ATTENTION: PROJECT: SUBJECT: Gentlemen: Mr. Clyde Haas Lot 7, Block 6, South Lakewood Hills Subdivision Septic Tank Pit Inspection Transmitted herein, in accordance with your request, are the results of an inspection, performed by the writer of the septic tank pit at the .project location. The depth of the pit had been extended to t3.0 feet plus by a backhoe. The material from 12.0 feet to 13.0 feet was a dark gray sand NFS, SP and no water was observed in the pit at 13.0 feet. This inspection was performed at 8:15 AM, July 15, 1975. If there should be any questions on the above, please contact our office. Very truly yours, ALASKA TESTLAB Laboratory Supervisor KWB/vms GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received 1. Approval requested by: Mailing Address: 2. Property Owner: Time of Inspection Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR ~--~-~- Phone: Mailing Address: 3. Legal Description: 4. Location: 5. Type of facility to be inspected 6. Well Data: A. Type ,, No. of bedrooms B. Depth C. Construction ~-',~-/~--~-- D. Bacterial Analysis Sewage Disposal System: /~ '~w~ ~z--~A~ ~-~-/. A. Installed C. Septic Tank: D. Seepage Pit: E. Disposal Field: Distances: A. Well to: Septic tank Nearest lot line B. Foundation to septic tank /¢ ?~F- B. Installer 1. Size /~ ~/,~ 2. Manufacturer 1. Absorption Area 2. Material Total length of lines , Absorption area , Other contamination , Absorption area C. Absorption area to nearest lot line , Sewer Lines EQ-034 (1/74) Page 1 of two pages ~Pa<J~ 2 of two pages - k~st for Approval Legal D~scrdption '? ~ ~ ~ of Individual o:wer & Water Facilities Approval Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74) [ ~' .~.:DEPARTMENT OF HEALTH AND SOCIAL . .CES DIVISION OF PUBLIC HEALTH INDIVIDUAL AND SEMI.PUBLIC BACTERIOLOGICAL'WATER ANALYSIS INDIVIDUAL [] SEMI-PUBLIC [] CHLORINE RESIDUAL PPM REPORT RESULTS Tg'~ NAME ADDRESS ADDRESS Lab No. OFFICE ~,A~alysls shows Ibis Water SAMPLE to be: ~ Safisfaclor¥ E Unsatisfactory ~ Questionable ~ Sample too long in transit; sample should not be over 48 hours old at examination to indicate reliable results. Please send new samoJe [] Bottle 0token in lransit, please send new sample, SANITARIAN'S REMARKS COMPLETE THIS SECTION ONLY IF WATER IS AN INDIVIDUAL SUPPLY SAMPLE COLLECTED BY DATR COLLECTED TIME COLLECTED ~ · ~ Sample Collected Fram I~l'Kitchen Tap [] Balhroom Tag [] Basement Tc~ [] Olher (List] Well -- [] Dug ~ Driven [] Drilled ~ Bored SOURCE: [] Spring [] Cistern [] Olher Dug Well or Cistern Constructiom Walls--[] Wood [] Concrete ,[] Metal [] Tile BHck or Top -- [] Wooc [] Concrete [] Mete [] Open Top [] Concrete LOCATION: GENERAL: Does Water Become Muddy or Discolored? [] ~es [] N~ Diameter of Well Deplh Feet. Well Caslng Material Diameter Depth PURPOSE OF EXAMINATION: Illness Suspected? [] Yes New Source of Supply? [] Yes ~ No Repairs ?o Syslem? READ INSTRUCTIONS ON REVERSE SIDE BEFORE COLLECTING SAMPLE 06 1220 ,~ BACTERIOLOGICAL WATER ANALYSIS RECORD Lactose Broth 1Otc 1Otc ?Oct 1Oct 1Oct 1.0cc /,Oct 24 Hours 48 Hours EMB AGAR Lactose 8roth, 24 hrs. 48 ~rs, Gram's stain Coliform Density Most orobable No. per IOOcc) MF Results Reported by This ana]ysls [ndicales Coliform Organisms to b&: Absent Clyde Haas Ju!y g~, 1975 Page taR Until thts matter ts resolved, tMs offtce ~s disapproving the sewer and water factllttes on th~s lot. Stnceeely, '~ susan E. Oswalt Saflttar~an SRO/st cc: ~arl ~111er RECEIPT FOR CERTIFIED MAIL--30~ (plus postage) ST,.REET AND NO~ :1 A P.O., STATE A~D zip CODE OPTIONAL SERVICED FOR ADDITIONAL FEES RETURN ~ 1. SHOWS tO whom and date delivered ........... 1~ WJth delivery to addressee only ............ RECEIPT 2. Shews to whom date and where delivered ,. SERVICES W th del very to addressee only ............ DELIVER TO ADDRESSEE ONLY .......................................... ~ ........... 50d SPECIAL DELIVERY (extra fee required) .................................... PS Form ' NO INSURANCE COVERAGE PROVIDED-- (See other side) Apr. 1971 3800 NOT FOR INTERNATIONAL MAIL * o~o: Je?~ o- 4eo-?4s RECEIPT FOR CERTIFIED MAIL--30~ (plus postage) STREET AND NO. /~ ' P.O., STATE AND ZIP CODE OPTIONAL SERVICES FOR AOOITIONAL FEES RETURN ~. 1. Shows to whom and date delivered ........... 15¢ With delivery to addressee only ............ 65¢ RECEIPT 2. Shows to whom date and where delivered ,. 35¢ SERVICES W th del very to addressee only ............ 85¢ DELIVEN TO ADDRESSEE ONLY ...................................................... SPECIAL DELIVERY (extra fee required) .................................... POSTMARK OR DATE PS Form 3800 Apr. 1971 NO INSURANCE COVERAGE PROVIDED-- (See other side,) NOT FOR INTERNATIONAL MAIL * ~o: 197d 0 - ~dO-~3 J~ 3L ~975' 3430 ~oc~ Circl~ .~nc~u:~ra~e, Alaska 99502 SUbJeCT: (1n-site s~wer system o~ ~t 7, BI~ 6, ~ ~ ~1~ $1, 1975 1) tt~ tnatall~t/~ of a ~dir~ trunk was ~le~al aha ~ let~r £s to ad~d~e you that thim ~ep~t w~ll not grmat ap~rov~ ~r If you hav~ ~',.y quear~bu~m c~mu:m~nmi.ng this mat~, p~ o~ntact th~s office a~ 274.-.4961. SENDER: ge ~u~e fo follow lnsfrucfiens on'other s;de · / PLEASE FURNISH SE~RVlCE(S) INDICATED BY CHECKED BLOCK(~)* _ ~ ~ Showtov~hom, dateandaddress ~ Deliver ONLY ~.~A~/~/~L_J where dehver,ed V o ,., ~ to addressee' FROM: GREATER ANCHORAGE AREA BOROUGH ........... ~_.__-.-. .......... -'-, z' DATE ANSWER TO: DEPARTMENT: "/~L J)~-~. REQUESTED: RECEIVER: REQUESTED ACTION SCHEDULE " ~EOR INFORMATION ONLY ~ PREPARE BACK-UP INFORMATION ~OR IMMEDIATE ACTION ~ CALL ME BEFORE YOU ANSWER ~ ~R YOUR CONSIDERATION ~ NEED YOUR RECOMMENDATION ~OTHER 'ED 89° 59' 'l~ J 0 PROPOSED CONSTRUCTION PLAN I hereby certify that I have surveyed the following described property:. Anchorage Recording Precinct, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach en the property lying adjacent thereto, that no improvements on prop- erty lying adjacent thereto encroach on the premises m question and that there are no roedways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska .'::::/" (-HEWITT V. LOUNSBURY & ASS¢CIATES Engineers, Surveyors & Planners/ FIELD BOOK No • lithitio i U * Municipality of Anchorage o On-Site Water and Wastewater Program e ' 'lir (907) 343-7904 5 Ar r T CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 015-151-26 Expiration Date: / '-O-7 / 7 1. GENERAL INFORMATION Complete legal description SOUTH LAKEWOOD HILLS #1, BLK 6. LOT 7 Location (site address) _11151 WILDWOOD DR ANCH AK Current Property owner(s) WELLS FARGO BANK Day phone Mailing address Real Estate Agent Day phone 2. TYPE OF DWELLING: ,\ 2 3 4 5 F_ ® Single Family (w/wo ADU) Q fi ❑ Duplex `ro 'NVQ ❑ Multiple Dwellings (Single Family and/or Duplex) c-: OL'�' /- 1 3. NUMBER OF BEDROOMS: 4 scA /. .% <" o - ' 4. TYPE OF WATER SUPPLY: TYPE OF W S�T'EWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver/Variance request for: Distance: Received by: /AA— Date: 7 2-7/( ? COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 117(a. Waiver Fee $ Date of Payment 4/25/0 Date of Payment Receipt Number 103q/ Receipt Number COSA# C5 / /-/G — Waiver# .. r1� le- 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm MIKE N ANDERSON, P.E. Phone 727-8864 Address 4661 NATRONA AVE. Engineer's Printed Name MIKE N ANDERSON. PE Date 9/23/17 •'• ',4:1�. .—!,5,...1 r. 1 • ,d* '01 : 12, 49TH • co 6. DS ATURE .•MICHAEL N. ANDERSON 94 9 ,04 System #1 Approved for bedrooms. 'E •/,,•—•.f •7i?5 •,.c�=L, 1 Fo .••• 11" ` System #2 Approved for bedrooms. ��N. a _„,:-- Disapproved. Conditional approval for bedrooms, with the following stipulations: ,,,ikoAkk tttirl F-V V V(1112,CeAik-4"40 6 (761.A.‘-(e-C, -:e 47/ `,, .. --..,...„.----„-- ----- r...... cor„:“; _t:LC 1-- < < < ;, 74. � ¢ Qt1 ti- BY _ wl QJ t 1-v —6 Original Certificate Date: C("2- I --1 7 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 10.10.12 Doc If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system _ Certificate of On-Site Systems Approval Checklist Legal Description: SOUTH LAKEWOOD 1111.1.~ 1, 13I.K 6, LOT 7 Parcel ID: 015-151-26 A. WELL DATA Well type Private If A. B. or C provide PWSID # Well Log (Y/N) N Date completed 1975? Sanitary seal (YIN)Y Wires properly protected (Y/N) Y Total depth 212 ft. Cased to 212 ft. Casing height (above ground) 18"+ FROM WELL LOG AT INSPECTION Date of test 9118/2017 Static water level ft. 121 ft. Well production g.p.m. 5+ g.p.m. WATER SAMPLE RESULTS Coliform NEG colonies/1 00 mL Nitrate mg/L Arsenic: ND ug/L Date of sample: 9-18-17 Collected by: Mike Anderson B. SEPTIC/HOLDING TANK DATA - Tank Type/Material STEEL Date installed 10/30117 Tank size 1250 gal Number of Compartments 2 Cleanouts (YIN) Y Foundation cleanout (YIN) Y Depression over tank (Y/N) Y High water alarm (YIN) NA Date of pumping NEW Pumper NEW C. ABSORPTION FIELD DATA— Date installed 10/30/17 Soil rating (sf/bedroom) 0.6 System type DEEP TRENCH Length 65 ft Width 2 ft. Gravel below pipe 8.0 ft Total depth 12.0 ft. Eff. absorption area 1040 ft2 Monitoring tube Y Depression over field N Date of adequacy test NEW Results (Pass/Fail) NEW For 4 bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) UNKNOWN If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off" level at in.High water alarm level at in. Datum Cycles tested Meets alarm &circuit requirements? E. SEPARATION DISTANCES- WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot *90'+ On adjacent lots 100'+ Public sewer main 100'+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 50'+ Holding tank 100'+ Animal containment areas 100'+ Manure/animal excrete storage areas 100'+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10'+ Property line 10'+ Absorption field 10' Water main 100'+ Water service line 50'+ Surface water 100'+ Wells on adjacent lots 100'+ ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10 Water main 100'+ Water Service line 50'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain 50'+(None Known) Wells on adjacent lots 100'+ F. COMMENTS NEW SYSTEM INSTALLED PER DESIGN G. ENGINEER'S CERTIFICATION n I certify that I have determined through field inspections and vim OF Ai:7\).) review of Municipal records that the above systems are int conformance with MOA COSA guidelines in effect on this date. r��•'� ••'�`V' art * • 4 9 T N ., ; Engineer's Printed Name MIKE N. ANDERSON, PEei /%'�'Y'� Date 1115/2017 • ..+ MICHAEL N. ANOLRSCN��'• C 469 COSA canary sheet_2-6-15.doc .- . ("iv '61.'4\ 30 S 89'59'00" E. 190.00 j -4112 s.- . Qf N. N. In cD or o \ 0 \ oENCLOSED UNDER U7 • y O . 6-- • o . rep, o . 14 1 TWO STORY Z p WOOD FRAME HOME — 28.4 WELL• I i • p o I �M r, r 1 i } ,CHAINLNK FENCE TYPICAL rt 30 73.38 S 89'59'00" E. 190.00 w o O E . 112th AVE . Bobby F. Burnett GRAPHIC SCALE, 1 Inch = 30 Feet 2941 Uarriage Drive Anchorage, Alaska 99507 ril II (907) 350-5541 15 0 15 30 60 ��'..\‘ Date Scale Legal Description 411r-c, OF .f 11/04/2017 1" = 30' / � `Q,' Lot 7 BLOCK 6 . Grid AS-BUILT ,` , 1 +_ SW 2638 SOUTH LAKEWOOD HILLS SUBD. , *4 • �� j`. Drawn by Field Book FIRST ADDITION r BFB ASB-2017 PLAT # P-611 0 I hereby certify that the property described hereon has been surveyed BOBBY F. BURNETT / by me, or at my direction, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the IS-6484 ' property lying adjacent thereto unless otherwise shown. That no 4‘4,, �7-q a?..... imp\1444...... rovements on the property lying adjacent thereto encroach on the 1 AV premises in question and that there are no roadways, transmission ` 33IONlLNAN. L AI } linea or other easements on said property except as shown. \` 1b:410.-