Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SOUTHPARK #2 BLK 2 LT 10
outhpark #2 Block 2 Lot 10- #020-501 -33 Municipality of Anchorage Pae 1 or 3 Development Services Department 9 On-site Water and Wastewater Program 4700 South Bragaw, Street P.O. Box 196650 Anchorage. AK 99519-6650 wwwclanchorage.sk.us (907)343-7W4 ONSITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO30140 Nr r PID Number. 020.501.33 Jason L. Roth Wastewater System: Upgrade 45841 South rk Loop Anch. AK 99516 ABSORPTION FIELD 345.7219 N b a19.aua M. FOur(4j_ Deep Trench Inspections performed by: MEA Dates: 1" 6116/03 Department of Health and Human Services ap pprovai6/18/03 Reviewed and 1099)y- approved b ( y ate: 4 / Rev. 099) 100.0 Ft Engineer's Stamp •••�gagees 49th 't'eei je00 0 cttMICHAEL E. ANDERSON W �Sr-\ No. CE -4381 J{� LEGAL DESCRIPTION Salr'A"e Tar Opmfrvnvq. 131� ta. acaHM.ott .45 ciWe 8 Ft. 2 10 South rkEftNo.2 DOM b VP bW from 2 *rV* Pr10. GrM "M e.n9.tn per. Ta"""9 Rrps: Sxnort: Ft. g Fa �meC Ft tcor�mprr �.w. Grt.ait•Vb: 2.3 Ft. 112 Well: Municipal Water System 3 Ft. 0111aM. b..n... n... CM`tW— (P"S. A S. CI: Taal DtpIR r.a9C b. alAl r Ft. 2 >12 FL DaMr FL 1'344 Flt ASTM 3034 PVC oreEENW atreWwrtwN.Ft Y Ft Faro So Acreage Systems 6116.611812003 r ca" Atwre Gtoub GF'" Ft. Ft TANK SEPARATION DISTANCES STEP To From Septic Absorption Lilt Holding uowprt ata Tank Field Station Tank sewerure r Anchorage Tank 1,500 W« >200' >200' >200' WA >25' Steel Two (2) at.r.9.wr. >100' >100' >100' WA LIFT STATION >10' >10' WA 250 GM Anchorage TanklOrenco FaMe1� >5' >10' >5' WA "'"°°" r .9t. K None Noted 42 in °irp "� • � 42 in 44 In. ewv.� frrp.acn.,.bm., q Rntrtu: Orenco Municipality of Anchorage BENCH MARK Garage Slab Inspections performed by: MEA Dates: 1" 6116/03 Department of Health and Human Services ap pprovai6/18/03 Reviewed and 1099)y- approved b ( y ate: 4 / Rev. 099) 100.0 Ft Engineer's Stamp •••�gagees 49th 't'eei je00 0 cttMICHAEL E. ANDERSON W �Sr-\ No. CE -4381 J{� Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 Permit Number. SW030140 On -Site Wastewater Disposal System or Well Inspection Report 42 M1 Ball Valve Connected To Existing Bed,, Four Bedroom Home =xisting 1,250 Gallon STEP fink Pumped, Crushed and Backfilled, PLAN AS -BUILT SCALE 1"= 30' LOT 10, BLOCK 2, SOUTHPARK BLUFF SUBDIVISION NO. 2 Page 2 of 3 PID No. 020-501-33 A a C 51 8.5 14.4 S2 10.7 21.6 MH 11.4 22.8 Mt 42.1 47.2 M2 45.3 60.0 Municipality of Anchorage Page 3 of 3 4700 South Brraagaw StreetTAAnchorage, AK 99519.6655 - 343-7904 Onsite Wastewater Disposal System or Well Inspection Report Permit Number. SW030140 PID No. 020-501-33 3/16'OrIFlces Q 4' NORTH LEG Y 50' (Trench Length) 3/I6'OrlFlces a 4' SOUTH LEG V 49th PROFILE AS—BUILT • ..�. - �mmmom �=MIOUEL L ANO[RS01 J�4,y N0. CEr381j Scale: T-10' �i=fd.N- /c� ID:O JUL 01'03 15:46 No -002 P.01 .. � 06/10/2005 Oe:J6 PAZ•:D07:�434211 1 BUILDING SAFEI -'— -.•• 0601 .�;SMALL ELECTRICAL PROJECT FORMS % NO. 2354 sP . Date of Work "/ <<.. Site address:Lot -A. Block_ Trect: Subdivision: :4= Elektrtcel Contrtraotor; : C p Phone: 0 Contact Penson: 2 Cal ,%e Ole Desotfpllon of Eleoklanl Work If this Is a rein'ntact electrf�t inspectors N there are any question'about this p WonPiss" Includo the original Small Electrical Project Form no. H Sketch of work and location F. Inspector's 1n A Pbonk%3 S This form can only ba used under the conditions defined ThIs firm must be completed be Building Safety Policy 040. '.• aginning work : . Permit Number: SW030140 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 l - Lop —1 Z -3L) Pm Z 1j(30V"— ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: May 19, 2003 Expiration Date: May 18, 2004 Parcel ID: 020-501-33 Legal Description: SOUTHPARK #2 SUBDIVISION BLOCK 2 LOT 10 Design Engineer. 0014 Anderson Engineering Site Address: 15651 SOUTHPARK LOOP Owner Name: JASON L. ROTH Lot Size: 0 SO. FT. Owner Address: 15651 SOUTHPARK LOOP Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. AK 99516 - This permit is for the construction of. ❑✓ Disposal Field E✓ Septic Tank Holding Tank [] Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907)343-7904(24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either. A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received BI Issued BI Date: Date: J 03 Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D.-020452-83� 0M_ Permit Number SW !7 30 140 Property owner(s) Jason L. Roth Day phone 345.7219 Mailing address (1)15651 Southpark L000 Anchorage AK99516 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 10, Block 2. Southoark Subdivision Addn No 2 Legal description (Section, Township & Range) Lot Size r33S 7_ Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms Four(4) Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade - 19 THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. 0,_,� , (Signature of property owner or authorized agent) Permit Fees:—�i�iiJ . Waiver Fees: Date of Payment: O 3 Date of Payment: Receipt Number: 1 Receipt Number: (Rev. 12/00) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) May 9, 2003 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 10, Block 2, Southpark Subdivision Subdivision No. 2 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The existing absorption bed on Lot 10, Block 2, Southpark Subdivision No. 2 has failed and must be replaced. We are therefore requesting a permit be issued for the construction of a new absorption system to serve the proposed home. The attached Site Plan and backup documentation identify the location and configuration of the new septic system and the parameters used in the design. Also identified on the plans are the location of the water service on the lot, the existing system and the test hole location. Existing drainage patterns are shown and will not be altered by the construction of the new system. The original septic system was constructed in 1988 and consists of a 94' long by 24' wide absorption bed. Test holes used to design that system indicated silty gravel materials to depths of 16' with percolation rates between 30 and 50 minutes per inch. No groundwater was noted at any time. Our test hole indicated similar results with better percolation rates near the surface of the lot. We are proposing therefore to construct a deep trench system with a 6' effective depth. The distribution pipe will be placed at 2' below the surface and the total depth will be 8'. A 1,500 gallon combination septic tank and lift station will be required to treat the sewage generated in the house and transport the effluent to the absorption area. Ball valves will be placed and the existing absorption bed tied in to the system for possible future use. The new absorption system will be constructed a minimum of 10' from the existing water service line, existing absorption bed and house foundation. Surface drainage patterns will be maintained after construction is complete. The ground surface on the lot slopes as shown on the attached Site Plan with a shallow slope near the proposed absorption trenches. The new trenches will be constructed on Lot 10, Block 2, Southpark No. 2 May 9, 2003 Page Two a fairly flat surface in conformance with Municipal requirements and parallel to ground contours where possible. All components of the new septic system will be constructed a minimum of 10' from the existing water service on the lot. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments ? 49th MICHAEL E. •NIERSIN! No CE -4181 i N N .p JS w 4k9 19 P 0 9000 ,P B � 18 68.30 Subdivisi Served.p Gemma $ By Munici Water;§y t No Confli With Ne h ring N$ep 1c Sy ms m R �. •12 e 10 s ,z P 4, vem 3 s g 14 `v A` O s en-: AREA MAP =t 49th ..._:....�. QIP.. •. Y�C�uEL E. ANDERSON � Z ♦��,' No. cE4,e, SITE PLAN -0 / Ilir J 49 SCALE 1' = 30' 'CI E. •HOER50N No. CE4MI LOT 10, BLOCK 2, SOUTHPARK SUBDIVISION NO.2 DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House Deep Trench System Perc. Rate: 40 Min./Inch 1,500 Gallon STEP Tank Application Rate: .45 GPD/SF 6' Drainfield Rock 4 Bedrooms X 150 GPD/.45 GPD/SF(Application Rate) = 1,333 SF Absorption Area 1,333 SF/12 SF/LF =I 11 LF Trench Length THEREFORE: Construct 2 - 56' Long x 3' Wide x 6' Effective Depth Absorption Trenches. Flow Line Elevation in Trenches to be 2' Below Original Ground Surface. Total Depth to be 8' Below Existing Ground. Maintain 10' Separation From Water Service on Lot. Provide 3' of Cover Over Trench and 4' Over Septic Tank or Provide 2" Insulation and 2' of Cover. Maintain 12' Separation Between Trenches. Natural Backfill Geotextile Fabric 6"'1' Perforated PVC (Holes Down) 6-0-1 1 ,>� Drainfield Rock 3' I ----I L DEEP TRENCH SE NOTE: Grade Area Over Trench to Drain Away. A 4L Minimum 6' Separation From Bedrock. i , ,,,` ,,,,, ,,,,,,, Minimum 4' Separation From Groundwater. ��il%r)� ��f Minimum200' Separation From Wells in the Area. i""'TIC ?W4,� Minimum 100' Separation From Surface Water or Streams. �i c s; M cw�` e.0 oEason Minimum 10' Separation From Water Service Line. ni si No. `E"°' ? r; 2 3 4 5 6 7 8 9 I( 11 17 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH 8 HUMAN SERVICES 825 L STREET, ANCHORAGE, AK 99502-0605 PROJECT #: M0319 SOILS LOG - PERCOLATION TEST PERFORMED FOR: Jason Roth LEGAL DESCRIPTION: Lot 10, Block 2. Southoark Subdivision No 2 TEST HOLE # 1 SL OG Gr Grass/Topsoil I , GM .2% Silty Gravel More Dense WAS GROUNDWATER ENCOUNTERED? NO IF YES, WHAT DEPTH? DEPTH OF WATER None AFTER MONITORING: DATE: 4/29/2003 roan E u« No. CEAMI BOH S L O P E DATE PERFORMED: 5/1/2003 SITE PLAN N See Site Plan <2% READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 5/1/2003 4:42 12.0" 1 5:12 30 5.625" 6.38" Recharge 5:13 12.13" 2 5:43 30 6' 6.13" Recharge 5:44 11.75- 3 6:14 30 S 7S" PERC RATE: S.0 MIN./INCH PERC. HOLE DIAMETER: 6" TEST RUN BETWEEN 2.0 FT. AND 3.0 T. COMMENTS: NO IMPERMEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST TEST PERFORMED BY: M. ANDERSON I, MICHAFL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: S/8/2003 2 3 4 5 6 7 8 9 IC 11 17 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH a HUMAN SERVICES 825 L STREET, ANCHORAGE, AK 99502-0605 PROJECT #: M0319 SOILS LOG - PERCOLATION TEST PERFORMED FOR: Jason Roth LEGAL DESCRIPTION: Lot 10. Block 2. Southoark Subdivision No 2 TEST HOLE # OG Grass/Topsoil GM Silty Gravel More Dense 4L BOH IN 2"r" WAS GROUNDWATER ENCOUNTERED? NO IF YES, WHAT DEPTH? DEPTH OF WATER None AFTER MONITORING: DATE: 4/29/2003 S L 0 P E DATE PERFORMED: 5/1/2003 SITE PLAN N See Site Plan .2% READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 5/1/2003 4:15 8.25" 1 4:45 30 7.38" .87" Recharge 4:46 8.38" 2 S:16 30 7.63" .7S" Recharge S:17 8.S" 3 5:47 30 7.75" FERC RATE: 40 MIN./INCH FERC. HOLE DIAMETER: 6" TEST RUN BETWEEN5�O FT. AND 6.0 T. COMMENTS: NO IMPERMEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST TEST PERFORMED BY: M. ANDERSON I, MICHAEL EMI_ MICHAEL ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 5/8/2003 PRESSURE DISTRIBUTION CALCULATION Elevation at Highest Discharge Point Pressure at Highest Discharge Point Liquid Level in Tank (Elevation) Diameter of Holes in Distribution Line Diameter of Distribution Line Hole Spacing in Distribution Line Length of Transport Line Diameter of Transport Line Q 12.4jr= 12.4(.1875)(.1875MS— .9748 GPM/Orifice _ .9748.30 = 29 GPM TDH = (110-100) + .0192(29)(29) + .000995 75) (29)I.bS (1.25) • a 10 + 16.8 + 12.9 39.7' 105' 5' Head 100' .1875" (3/16") 1" 4' 75' 1.25" Therefore 30 Orifices @ 4' Spacing With 39.7' Total Dynamic Head. S 350.00 - I t EFFLUENTPUMPS 1/2 Hp to 11/2 Hp 4 SINGLE PHASE, 60HZ 115/2W VOLT .20 OSI 15 HHF - 9 stage PC#2 J IT. F; 300.00 if, 1{ i It 4. if fall -It if, -4- .io OSI 10 HH stage 250.00 - :7- N 1 it -LL if .......... Aj- . N I j I if 200.00- ii Ill I if •14+ 7 _i� I 44- HHF-5 < If Z> 150.00 - L :If Is 444. -4- 100 00 f L—L L2 If IN _L _L 44-4- 44-1 7 :1 1 if I 40 OSI 05 HH - 2 stage" 50. 00- it I it I 39.7 IJ 4- ... .. . .. TDA If: A niu 51i L if 200SIOSHHF-5 stage If -4- '-t w / 1/4" flow controller f 0.00- o.oD 5.00 .10.00 15.00 20.00 25.00 100 35.00 40.00 45.00 50-00 GPM' NET DISCHARGE, GPM LqRENCO SYSTEMS, 94" COLONIALROAD ROSEBURG, OR9747U (503)673-0165 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 10, BLOCK 2, SOUTHPARK SUBDIVISION, NO. 2 GENERAL: The scope of this project includes the removal of the existing 1,500 gallon STEP tank on the lot. It also includes the procurement and placement of a new 1,500 -gallon STEP tank at the location shown on the site plan and the construction of 2 new 56' long by 3' wide by 6' effective depth absorption trenches also shown on the Site Plan. The total depth of the trenches will be 8' below existing ground and the distribution pipe will be placed at 2' below the surface. All components of the new absorption trenches and septic tank must be constructed a minimum of 10' from the water service on the lot and 100' from any surface water. Insulation will be required atop the trenches to prevent freezing. A minimum of 4' of cover is required over the STEP tank. In lieu of cover 2" of insulation and 2' of cover may be provided. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK/LIFT STATION INSTALLATION The 1,500 -gallon STEP tank must be constructed by a certified tank manufacturer. Construction shall include an 18" manhole to provide access to the lift station. 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Lot 10, Block 2, Southpark No. 2 May 9, 2003 Page 2 of 3 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 4. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 5. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drain field. 6. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAIN FIELD CONSTRUCTION: The drain field shall be constructed to the dimensions shown on the design. The bottom of the trenches shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drain field rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drain field rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drain field are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drain field rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: The lift station must be constructed by a municipally approved septic tank manufacturer. An Orenco 20 OSI 05 HHF-5 pump is recommended. Lot 10, Block 2, Southpark No. 2 May 9, 2003 Page 3 of 3 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES Environmental Health Division 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Name DISTANCES R& -x 71-fZ%.-R Tp SEPTIC ABSORPTION Address FROM TANK FIELD WELL $wX 309 , eR WELL .��.y� Phones) Permit No. No. of Betlr oms v,+.+ '/' ?ice '%- -8'33 ig's, LEGAL DESGNIPTION LOT LINE 30 .y /off Lot Block Sivision © 'q_ S% azL7/f 3>'wx Z FOUNDATION Township, Range, Section I / / T l� 2 S�� AS -BUILT DIAGRAM (Show location of well, septic system, property lines, foundation, LJ driveway, water bodies, etc.) TANKS K SEPTI C U� _17*Z ❑ HOLDING Manufacturer 4 6 Q� pacify m gallons n(.L . l _ /.. I� S , y Material No. or GOmpanmenta TYPE OF SYSTEM ❑ TRENCH BED ❑ W. DRAIN ❑ OTHER Depth to pipe bottomfrom > Total depth from original grade original grade Oo S• /a $rS FT �—,3 L Nor -"ePr= FT Fill added above original grade Gravel depth beneath pipe ,?— FT 0,5" FT Gravel length Gravel width FT Z® FT Total absorption area Distance between lines / IrVO SO FT 1 S FT Number of lin Soil rating Pipe material 3/Z SO FT % b�/O IW Installer pp C" Date Installed N,e.VL'tz �'1 S WELLS ❑ PRIVATE �< OTHER tldentity) Date Installed: REMARKS: Dale: this inspection was perlormed according to all Municipal and Slate guidelines in effect an this dale: Health Department Approval: —1/ F/ )13(3/85) SEAL d ~ - ��STALL FE� ��qI��EERS ATTACH�D A��R��ED �ESIm AFlER HOURS CALL 313-4681 A�D iEAVE A �1[�SE'AGE g[� RECO��EP l CER[IFY TF!AT: 1. I am �amiliar wit� the requirements �or on-site sewers and wells as sei [orth by t�e Muric1paliiy n� Anchorage %M[A) and e �La�I. Iy Alaska. 2. l w��l install U�e systen in acco,�ance w�U� all ��O� co�es and re�ulai�ons, and in compiia/�c� with t�e �esign c,i!eria o�this perpit T, I will adhere Lo all �OA and Siate o��las�a requiremenis �or the sei baci 6�s1ances �/om any exisiing we�l, *asiewaLer �is7osal sys�em or �ublic . s����arage sysiem rn th1s or ��y a�jac��r� or nearby lot. 4. I undersiand that �h�s �ermii is vali1 �nr a maximum v; 4 hec|rooms. I alsu un�e�stand that ii�e capacity of t�e Lot`al system is 4 �ed,00ms �nd any enlar�emenL �ill requ�re an ad�i�ional permii. Signe�: " TU�mER 8 -/��^^��� LU!L THE TURNER COMPANY April 13, 1988 Municipality of Anchorage Dept. of Health & Human Services P.O.Box 196650 Anchorage, Alaska 99519-6650 IN RE: 10/2 SOUTHPARK SUBDIVISION # 2 To Whom It May Concern: Please be advised that this letter is written to authorize Alice A. Smith to act upon my behalf, to sign any and all paper work necessary for my company to obtain a septic permit for the above referenced property. Thanking you in advance for your consideration to this request, I remain, Sin e ely, Rexford L. Turner PRESIDENT MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH 8. ENVIRONMENTAL PROTECTION APR 2 01988 RECEIVED 4155 Tudor Centre Anchorage, Alaska 99508-4155 (907) 562-5881 P.O. Box 3489 Palmer, Alaska 99645-3489 (907) 745-8334 A onff e EC ALASKA MUIROfl nTAL COnTROL SMUICC�;J�41 L,,A OFANCHORAGE Cs ENVIRONMENTAL SERVICES DIVISION a �ngineerinq & �nuironm¢ntal Studies • SPECIFICATIONS FOR A TRENCH -TYPE WASTEWATER DISPOSAL SYSTEM 1'PR 1 51988 SOUTH PARK SUBDIVISION #2, BLOCK 2, LOT 10 1.0 GENERAL RECEIVED 1.1 The drawings, sheets 1 through 5, shall be a part of this specification. 1.2 All materials and workmanship shall meet the requirements of the Municipality of Anchorage, Department of Health & Human Services (DHHS), the conditions of the permit, and all applicable rules and regulations currently in effect. 1.3 All elevations and depths are advisory, and are to be verified or modified in the field by an DHHS approved inspector. 1.4 Ii is the responsibility of the installer to adhere to approved designs for installation, maintain the specified separation distances, and have the appropriate .inspections. 1.5 If the installation is not inspected by an AECS engineer, AECS will not be responsible for the design. An engineer at AECS should be consulted prior to construction, to determine the number of inspections that will be required and to explain what these inspections will involve. 2.0 SEPTIC TANK 2.1 If there is an existing septic tank it may be used if it meets the capacity requirement for the residence and the approval of the MOA. 2.2 The septic tank shall be a UPC -Approved two-compartment tank, constructed of 12 -gauge steel with bitumastic coating and set level on undisturbed soil. If the tank is buried at a depth of 4 feet or less, it may be insulated with an overlying layer of 2 inch burial type polystrene rigid board insulation. 2.3 The septic tank and bed shall be a minimum of 100 feet from any private well or body of water, 150 feet from Class C wells, and 200 feet from Class A or B wells, unless otherwise specified. Less than the required separation distance must have prior approval or waiver by ADEC or MOA. 2.d The septic tank shall be a minimum of 5 feet from the house foundation, and a minimum of 10 feet from the absorption area. 2.5 Piping shall be fitted with a mechanical watertight calder coupling on the outlet and inlet of the septic tank. Piping shall be 4 -inch solid PVC ASTM D3034 or cast: .iron, sloped a minimum of 1/4 inch per lineal foot. If the piping is buried at a depth of 4 feet or less, 1200 West 33rd Auenue, Suite B • Anchorage. Alaska 99503 •(907) 561-5040 it must be insulated with an overlying layer of 2 inch burial type polystrene rigid board. 2.6 Cleanouts shall be installed as designated and capped with air -tight rain caps (Jim caps or equivalent), and extended a minimum of 1 foot above ground level. 2.7 If a lift station is required it shall be combination lift station septic tank per Anchorage Tank and Welding, Inc, design. Specifications are attached. 3.0 Absorption Area 3.1 The gravel for the trench shall be 0.5 to 2.5 inch, screened rock with less than 3% passing #200 sieve residual. All substitutes must have prior DHHS approval. 3.2 The bottom and sides of the excavation shall be raked with the backhoe blade to insure that it has not been compacted during excavation. The bottom elevation shall be level. 3.3 Monitor standpipe(s) shall be placed as shown in the drawings, and shall be rigid RVC ASTM D3034, or 4 inch cast iron. The section shown with holes may be 0.5 inch holes drilled on 6 -inch centers on opposite sides of the pipe, or a regular section of perforated sewer pipe, clamped to a solid section, with either a no hub coupling or a solvent joint. A rubber rain cap (Jim cap or equivalent) shall be installed over the top of the pipe. 3.4 The distribution pipe shall be 4 inch rigid PVC with a minimum crush strength of 1500 lbs. All distribution pipes shall be laid level. 3.5 Trenches may be paralleled, but must have a minimum separation distance between the trenches of 6 feet or 2 times the gravel depth (whichever is greater). 75 feet is the maximum allowed linear length of any trench. 3.6 If the final grade over the trench is less than 4 feet above gravel, insulation is required, using the burial type polystyrene rigid. There shall be 1 inch of insulation for every foot of soil less than the required 4 feet of cover, but there must be at least 24 inches of soil cover even though insulation is used. The solid pipe extending from the septic tank to the drainfield shall also have 4 feet of cover or an equivalent layer of insolation to prevent freezing of the line. 3.7 If insulation is not necessary, the gravel shall be covered with a layer of nonwoven Geotextile fabric (such as Mirafa.i, Fibretex 200 grade, Poly Filter Y or equivalent). 4.0 INSPECTIONS 4.1 A minimum of two inspections are required for the installation of the trench. The first inspection will be of the excavation to verify that installation will be in the proper soil. 4.2 The second inspection will be after placement of the gravel, monitor standpipe and distribution pipe to verify proper installation before backfill. Anchorage Tank & welding, Inc. 2700 Porcupine Dr. - Anchorage, Alaska 99501 - - (907) 272-3543 i.. TANK FOR LIFT SYSTEMS A. SEPTIC TANK SHALL, BE A MODIFIED F1NCUORAGE TANK • STEEL TANK; THE DESIGN OR ANALYSIS SHALL BE IN ACCORDANCE: WITH ACCEPTED ENGINEERING PRACTICE AND LOCAL, REGULATORY AGENCIES. B,, THE: TANKS SHALL BE DESIGNED FOR LOADING S S' AND STATE. 1 •t MUNICIPAL f tN.Es t TRET BY MJ CONDITIONS A., REQUIRED REGULATIONS, Cr ALL WELDING SHALL BE IN ACCORDANCE. WITH APPLICABLE CODES AND tSTANDARDS, D COATING, SHALL.: DE TNE:MEC; 46-465 HI -BUILD TANK COATING AND APPLIED AS FOLLOWS: 1. SURFACE: PREPARATION - ALL SURFACES MUST BE DRY, CLEAN, AND REASONABLY FREE OF RUST AND MILL SCALE EXCESS RUST, MIL.L., SCALE: AND j WELDING SLAG SHALL, BE R!:Mt]VEi:i BY W.T.(dE BRUSH OR OTHER MEANS AS NECESSARY. 2, APPLICATION SHALL. BE: AIRLESS SPRAY TOUCH UP WITH BRUSH OR ROLLER, 3. THINNING SHALL BE ACCOMPLISHED WITH APPROVED MATERIAL. AND WILL NOT EXCEED 50 4. SURFACE TEMPERATURE :SHALL NOT BE: BELOW 401=' OR 5 BELOW DEW POINT WHICH EVER IS (_.OWER. I ' =� Anchorage Tank &Welding, inc. - 2700 Porcupine fir. - Anchorage, Alaska 98501 j907) 272-3543 i 2, RISER A, OUTLET" RISERS SHALL., BE GALVANIZED STEIL: CULVERT, AND SHALL BE G+C INCHES (MINIMUM), HIGH, SHALL.; HAVE A MINIMUM NOMIMAL DIAMETER OF 24 INCHES, AND SHALL BE CAPABLE. OF BEING EQUIPPED WITH THE FOLLOWING:' A. A JUNCTION (NEMA 4X) BOX OR f::WlJAK, BONDEIa 0R ATTACHED TO THE RISER. B. UL LISTED ELECTRICAL. CORD GRIPS, INSTALLED IN THEE J- --BOX-A, A LID -- SHALL BE FURNISHED WITH THE RISER, IT SHALL. BE. CONSTRUCTED OF 'FIBERGLASS OR EQUIVALENT AGGREGATE FINISH. C. RISER INSTALLATION — EACH RISER SHALL BE: SEALED OR WELDED TO THE TOP OF THE:. TANK IN SUCH A MANNER j AS TO PREVENT INFILTRATION OF GROUND WATER j WHERE. PRESENT,' D. INSULATION 2" RIGID EXTRUDED POLYSTYRENi'! SHALL BE PLACED IN THE RISER DIRECTLY BELOW THE LID, E. INSULATION - 2" SPRAYED URETHANE ON CIRCUMFERENCE OF RISER. . z Anchorage Tank & Welding, Inc. -.2700 Porcupine Dr. Anchorage: Alaska 90501 - NOT 2720543 3, EFFLUENT PUMI':I:NG ASSEMBLY A. EFFLUENT PUMPING ASSEMBLY SHALL BE ORENCO SYSTEMS (TM) MODEL OST WE :1.000 SERIES CONSISTING OF FOLLOWING:; 1.. 1/3 H.P. MYERS SSM25 11b VOLT OR EQUAL 2 SCREENED PUMP VAULT (UA PATENT 04439323) 59" DEEP, '3/16'" TIICK,HLGH-DENSITY PVC C',YCLINDE::R HOUSES THE: PUMP, LEVEL, CONTROLS, AND SCREEN AND SERVES AS A BAFFLE TO PREVENT THIN SCREEN FROM CLOGGING THE FIF TLEN 1-•1/2" IIIA. HOLES ARE DRILLED 114 ;THE VAULT AT A LEVEL THAT PLACES THEM AT ABOUT THE MIDWAY POINT IN T'HI'N: DEPTH OF THE SEPTIC FLAP CHECK: ALLOWS THE. VAULT TO DRAINWHEN REMOVINI:.FROM TANK, SCREEN; 15" DIA, CYLINDER OF HIGH-DENSITY POLYETHYLENE I:& MESH CAST INTO FIBERGLASS BOTTOM. 3, AL•!... PL..UMBING SHALL BE PVC OR OTI-CR NON CORRODING MATERIA..:, B, PUMP CONTROLS AND ALARM SYSTEM CONTROL. SHALL.: BE ORE.NCO SYSTEMS (TM) ML.. -3F CONSISTING OF1 1.. AUDIBLE ALARM PANEL MOUNT WITH A MINIMUM OF SO DB SOUND PRESSURE AT 24 -INCHES, OPERATING TEMPERATURE 30AC? TO 65AC, CONTINOU S SOUND. { 1 ; _ Anchorage Tank & Welding, Inc. 2700 Porcupine Dr. \� - Anchorage, Alaska 98501 J t - - (907) 272-3543 2. OIL --TIGHT VISUAL ALARM WITH PUSH -TO -SILENCE ,. F1'..ATURE. AUTOMATIC AUDIO—ALLARM RESET', 3, 3, :1.:3 AMP MOTOR RATED TOGGLE SWITCFI, SINGLE POLE, DGULjLt. THIdUtJ WITH THREE POSITIONS; MANUAL (MAN), AL!TOMA-rIC (AUTO), ANL, CENTER tL (OFF) (11,0,A.), RLCOMMENSlA'r:1:OPdS ANDSTANDARDS t "NEMA ,dX—RFaTIi:I), FIBERGLAS .OR EQUAL, E:NCLO;WRE WITH HINGED .COVER, C, LI.VLL, CONTROL FLOATS SHALL. BE Ot.I:'.NCi:? SYSTEMS ('rM7 I MF2 CONS.IST"ING OF' 2 MERCURY FLOATS ON Al, JUSTP,ItL,E;: PVL' STEM WHICH ATTACHES TO VAULT - ONE FLOAT SIONAI.,S ALARM,' THE OTtll'.I1 SWIlCIII £i PUMP ON C?Ff", P; r D. INSTALLATION. ALA, PUMPING SYSTEMS SHALL, ESI: f INSTALLED IN ACCORDANCE WITH ii'f:: MANUFACTURER'S RLCOMMENSlA'r:1:OPdS ANDSTANDARDS 1/3 hp effluent pump, va 4ous manufactures Reserve Cap=ty M GAUGE 121 1/2' 810 above Alo,rnm 209 GAL 221 GAL 333 GAL Reserve Capaoty 97• 48 1/2' <4 BEDROOM) above Pune on- 260 319 GAL 415 GAL pacrtY Between (5 L 6 SEDROOM) Pump an 4 Pulp off 112 GAL 113 GAL 176 GAL Alam 46' 47 1/2-1420 Float Levet an 43. 44 1/2• 39' Settings Off Sr 40 U2' 36' LIFT STATION DATA 1250 M GAUGE 121 1/2' 810 40 1/2° (3 BEDRnM 1500 12 GAUGE 145 97• 48 1/2' <4 BEDROOM) 2000 10 GAUGE 194• 129 MY 64 5/9' (5 L 6 SEDROOM) SIZE CHART NOTE — LIFT STATION TANKS MUST BE 250 GALLONS LARGER THAN STANDARD TANKS F13t SAME APPLICATION W➢TTC- CCC. ATTAPIST ALASKA ENVIRONMENTAL JOB ��a �Z Soot parEt Z CONTROL SERVICES, INC. 1200 West 33rd Avenue, Suite B SHEET Ho- of S ANCHORAGE, ALASKA 99503 CALCULATED BY '4 2� «✓ DATE (907) 561-5040 CHECKED BY DATE' l c93.5 iZX15TINo ru-xw.. • �� 92.2 '.':PROPobao `.e�aV. ,�-- 5U2FACA DYa1r1ACoB p'oFAZA 4k •......... {� r�' re • e/1 jell CD�I/•�• OY C. 44 REID JR e J PV 9� ' �i� '• CE -225, Lor /o 2:$ 575 t l n N 2 907 ati st s�' Z, P�T.,9RIV6}ypi •�� 42 n. S-7 9- �� s (Le6.n. (TYAc+L� �.p 7t torr 1 TRM -TDP OF R6 9 mm -.ss 3 _ PLOT PLAN ' X - - AS BUILT XENNETH G. LANG, L.S. 1731 GEORGE .BELL _CIRCLEr-ANCHORAGE, ALASKA 99515 T I HAVE SURVEYED THE FOLLOWING DESCRIBED - SCALE (907) 395-6976 I HEREBY CERTIFY THA _-B�� i0 u - PROPERTY, LOT 10 BLOCK'Z h00 H / n •••,.... tC', "� '&WCV40R.nG:H RECORDING DISTRICT, ALASKA, AND THAT THE IMPROVE- G of : • fi r MENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND DO NOT �� `li'r`y:'•�,"+ ENCROACH ONTO THE PROPERTY ADJACENT THERETO, THAT NO IMPROVEMENTS. �y ON THE PROPERTY LYING ADJACENT THERETO ENCROACH ON THE SURVEYED r1 PREMISES AND THAT THERE ARE NO ROADWAYS, TRANSMISSION LINES OR a YERNEiI L fiC H ty OTHER VISIBLE EASEMENTS ON SAID PROPERTY EXCEPT AS INDICATED ,HEREON. - - :.�•�,. • ......•,•• ,�1 DATED THIS THE 2.5 DAY OF Ml1 LL*i r 198$, AT ANCHORAGE, `+��•+ �' � D~ ALASKA. - z O s r3 s� a " 9rr1 q�All n N � IZ':. zSo 6 \ A. Lo as.3 D Ss•9 s�5•S° 585-251'02 Yzl . lO Tai. wts�—sPss�+nNr �F«+Nn-`Ja Rsrn2 nc.�� LOL9-- PLOT PLAN 'jC AS BUILT - SCALE .,ENNETH G. LANG, L.S. 1731 GEORGE BELL CIRCLE,_.ANCHORAGE5 ,._ALASKA 9951. -(907) 345-6476 --.I I: HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: LOT 10, BLOCK Z "{jpu."'PaR'.KSU�S�n1151 i.1 OD 2 r - co ,.-•�•.191, a _ _ rrt n A - NC"oa.N w6' - RECORDING DISTRICT, ALASKA, -AND THAT HE IMPROVE .cj ' t M TS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND DO NOT 47�•43`C"=� *u14 ENCROACH ONTO THE PROPERTY ADJACENT THERETO, THAT NO IMPROVEMENTS ON THE PROPERTY LYING ADJACENT THERETO ENCROACH ON THE SURVEYED to PREMISES AND -THAT THERE ARE NO ROADWAYS, TRANSMISSION LINES OR Ilk .y,EQp{G. win- OTHER VISIBLE EASEMENTS ON SAID PROPERTY EXCEPT AS INDICATED 1q '. CS-5202 HEREON. wf.............o¢�Y Tu _,ANCHORAGE,.,_-, DATED THIS THE �.:�S� DAY OF V�, 198 "I AT ..::ALASKA. MUNICIPALITY OF ANCHORAGE +.rl DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION �825 L. Street, Anchorage, Alaska 99507 264-4720 SOILS LOG — PERCOLATION TEST OILS LOG PERCOLATIONS TEST PERFORMED FOR: - DATE PERFORMED: LEGAL DESCRIPTION: T/7 ,53-7Q 6 .So,iti ���k� AW 2 B �i �' /C 'xi, '3 T1) W X49' - SLOPE SITE PLAN 9 rx m 4 cpm 2 'a 3. y,4.%e 5 t_ 1 6 t a 7 9 WF 10 11. 12- 13 - w` ?; i 14; 15- 16- 17- i' tc U C. Reid, A� T o. 2251E •��� �%k 'OROFESSO l bran }o grsy- tya.un s(1 { Y spa Y cZ ro(Y.t I/ if a i 5(tykjly Mere,, (arGCr Cv6v J TH. /3o 7Toy WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? S �L/C1/L/)� L O P E 90 Reading Date Gross Time Net Time Depth to Water Net Drop 3/3t 90? 43� 30 2,2,4 l.$q ' ND qyo Ible, - 3.0 zyl 2 32 ,oq Oy- PERCOLATION RATE SD (/minutes/inch) - TEST RUN BETWEEN ___L_— FT AND FT COMMENTS®®0®®®0E6 S / /SS f b/C '�v o frfe Sc�1�, s!js4r. PERFORMED BY: �f�J.A�,f%S CERTIFIED BY: 72-008 (6/79) DATE: PERFORMED FOR v)lorrsT ILS LOG MUNICIPALITY OF ANCHORAGE -DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST 625 L. Street, Anchorage, Alaska 99501 264-4720 - SOILS LOG — PERCOLATION TEST LEGAL DESCRIPTION: To TF T4oG/E M MF Cv 2- 3 3 cm gray quovP� Cf11hm 0, Yo it EJ •• eroYReid, Jr. tri" No 2251-E O ROFESSIONP`a SLOPE DATE PERFORMED: 2 6 Z Llj} ex 3j4 ttlw R- SITE PLA WAS GROUNDWATER S ENCOUNTERED? L Depth to Water Net Drop P E IF YES, AT WHAT DEPTH? ■■NEEM■■■■ MENNEEMMEN Mir■■■■■■■■ ■■■■■■■■■■ Reading Date Gross Time Net Time Depth to Water Net Drop S'3 I fNd� 1/4 /6 36 .7a , /D yrr,o yr/7 9; 70 /d PERCOLATION RATE `T� (minutes/inch) TEST RUN BETWEEN FT AND FT PERFORMED BY: /3GUey-7S CERTIFIED BY: 72-008 (6/79) - unicfpc' my ®H Anchorage January 12, 1988 P.O. BO; 196650 ANCHORAGE, ALASKA 99519-6650 (907) 343-4200 )TO MrAnom B.X Tom Fink, MAYOR DEPARTMENT OF HEALTH & HUMAN SERVICES Rexford L. Turner/Jim Jett PO Box 3489 Palmer, Alaska 99645 Subject: Lot 10 Block 2 Southpark Subdivision #2 A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1987. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site sewer system, the original as -built inspection report (three-part form) must be sent to this office for review and approval, and for documentation. Effective January 1, 1988, a new fee schedule is in effect. When re -applying for a new permit, the new fees are; $90.00 for an on-site sewer permit; $50.00 for a well permit; $140.00 for a combined sewer and well permit. If there are any further questions, please call this office at 343-4744. Since y, r Robert W. Robinson Program Manager On-site Services RWR/ljw enc: Copy of Permit 11UNICIPALITY OF ANCHORAGE Department of Health & Human Services 825 L Street, Anchorage, Alaska 99501 343-4720 0N-S1TF 8EWER pERMTT Permit Number: 870216 Data lsoued: 08/12/87 Owner Name: REXFOSIP L. TURNER / JIM JEFF Day Phone: Owner Address: FO BOX 3485' 745-8334 PALMER, AK 99645 Parcel Id: 020-052-94 Lot Lnqei: Subdivision: JOUTHPARK #2 Lot: 10 Block: 2 Sections 3 Township: 11N Range: 3W Lot Size 23575 (sq^ft. or acres) Max Dedrooms: This Permit: 4 Total Capacity; 4 SEWER SYSTEMS: Listed below are the options available to you in designing your sewer system. Choose the option that best fits your site.. T P E N C H B E D W. U R to I N Depth to Pipe Bottom (ft): 4.0 4,O 4,0 Hravel Depth (ft): 5,0 0.5 3.5 iota! Depth (ft): 9.0 4.5 7.5 nravel Width (ft): 2.5 30.0 5.0 ?ravel Length ([t): 152.0 :* 60.0 ** 164.0 ** Gravel Volume (cubic yds): 77.1.1b6.7 121.5 Soil Hatinq Used (sq [t/hrm): 300 279 380 ** Gravel /lengLh > 50 feet requires multiple soils tests:: ** Grave] length > 75 feet requires multiple runs (not exceeding 75 ft each),, SEPTIC TANK: Minimum total sepiic tank caparity: 1;230 Each septic gallons. tank must have at least 2 compartments. Depth to top of septic tank(s) < 4.0 Wet reouires insulation rvpr tank(s), LIFT STATl= I[ a lift station is installed, a high water alarm must be connected to the residence` ADVISE TITS OFFICE PRIOR TO THE FIRST AND SECOND INSPECTIONS, 0,U9 TELF-P113NE NUMIER I3 343-4740 !-\ 11;illLIT PAL ITY 0F 1)14C140RAGE Department o[ Healtn & Human Services SA25 L Street, Anchorage, Alaska 77501 343-4720 ONJ-SITE SEWER 1? EV RMIT Permit Numbe,: 870210 Page 2 1 CERTIFY THW: 1. r am familiar with the requirements for on-site sewers and wells as set forth hy the Municipality of Anchorage (MOA) and the State of Alaska. 2. 1 will install the system in acco,dance with all MOA codes/ and regulations, and in compliance with the design criteria of this permit, 3. I will adhe,e to all MOA and State of Alaska requirements For the set back distances from any elisting well, wastewater disposal system or public sewerage system on this or any adjacent or nearby lot, 4. T un�erst is valid for a maximum of 4 bedrooms, I also und K the total system is 1 hedrooms and any enla will require an additional permit. �� � Girne�: L/ DAT�: �y ------T---`---'------^--------------- ----`----------- (Owner> L �EXFOR"I lssued }�y: D4TE: THE TURNER COMPANY August 10th, 1987 Municipality of Anchorage Dept. of Health & Human Services P. 0. Box 196650 Anchorage, Alaska 99519-6650 In Regard: 10/2 Southpark Subdivision #2 To Whom It May Concern, Please be advised that this letter is written to authorize Jim Jett to act upon my behalf, to sign any and all paper work necessary for my company to to obtain a septic permit for the above referenced property. Thanking you in advance for your consideration to this request, I remain, Sin eely, // i Rexford L. Turner President RLT:hlm P.O. Box 3489 Palmer, Alaska 99645 (907)745-8334 A rc. ALASKA MUIROhR nTAL COnTROL SCRUICCS, InC. 5 o Cngineerinq & 6nuironmental Studies 1200 West 33rd Auenue. Suite B • Anchorage. Alaska 99503. 907) 561-5040 To Municipality of Anchorage Department of Health & Human —rviees--_.. �_ . �_-__ ---A% _naTe_Au9ut �� 825 L. Street ------Anchorage,—AK:-53950 SUBJECT _South Park Subdivision #2 Lot .10, B1k. 2 On July 24, 1987 we reinstalled a slotted monitor tube in the testhole, 83-70A to a depth of 15.5 feet. On July 31, 1987 there was no water detected in the Y •' - _ ��+e rte/ - 100,0. ,� - .. .: ... j . ,,. - sM;"!iFl. �iRLO:'C".pS:'Y��.}t! .Y•�',+wd� ;:Y.. - :._:/,., v ,i. _ _. is t •?,� �M—V �°� ' . .�V•e��.ae��®�: P yy�� -Aty 04 l�i � i ,. • • ne eeereoe.aotae� Y ce-223x ; c�56�- Ar 'c S �• 90 7 s 6 g 2S:o ZS.o a_ fG N . 7.0 L r9T lD 76'7 - w q Z3/5�. i9 N �F It'i „ o L2s n N `1 �� y 585-25-02 i ls-, raL.f, p si slwatls 1 '' FOUND -/S (LIAR. �TjemG PLOT PLAN ' X - AS BUILT r. - ,. SCALE I 3 _ KENNETH G. LANG, L.S. 1731 GEORGE BELL CT-RCLEi.-ANCHORAGE,, ALASKA 99515 (907) 345-6476 I HEREBY CERTIFY THAT I' HAVE SURVEYED THE FOLLOWING DESCRIBED it OF PROPERTY: LOT. 1BLOCK'2'f7G1erFC'Pd(L1'—S},i�Stin115i0rJ./a�O�Z , �da��. ,..Y•����iy AWCHo2s6i RECORDING DISTRICT, ALASKA, AND THAT HE IMPROVE- 4 y'�. 14ENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND DO NOT S4� ENCROACH OUTO THE PROPERTY AQJACENT THERETO, THAT NO IMPROVEMENTS , Q" ON THE PR02ERTY LYING ADJACENT THERETO ENCROACH ON THE SURVEYED �'1 �' -t C yr it PREMISES JUM THAT THERE ARE NO ROADWAYS, TRANSMISSION LINES OR OTHER VISIBLE EASEMENTS ON SAID PROPERTY EXCEPT AS INDICATED -•.aaa HEREON. - �•�'�„ •.• L3.5201, C`�Y •'•• aaJ�4p DATED THIS THE 1DAY OF �lr , 198 r AT ANCHORAGE, .- MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-0720 SOILS LOG — PERCOLATION TEST m. ...T XIM90ILS LOG PERCOLATION TEST PERFORMED FOR: DATE PERFORMED: LEGAL DESCRIPTION: %O B -50-%h of -P Ala 2 Z L' 16 �t` B PtJ A 3 ar /�am SL I I SITE PLAN Fog 1 'r 2 broon 70 gray-bra.on t sll+y Jew} Brave! 3 �` q✓ave{ �(� ,� (/v r. 4;' m' 3 5 6 7 8 *" .. t. � 5(�gM(y m>re F lo�gc-r yvavel 9 10 11 12 13 14 15 16 17 Date r,.A k "111lowH Net Time Depth to Water Net Drop 3/31 a .7c 2,11 1.01 1R qyo r`aao 30 zyl 2 37 'D Reid, Jr. ;•�V� �7 D 1. ii o. 2251 -E. °'t•,j�6' a1��pROFESSIO�:;� WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Q Reading Date Gross Time Net Time Depth to Water Net Drop 3/31 90? $3? .7c 2,11 1.01 . ry0 qyo r`aao 30 zyl 2 37 'D /o yo �7 D 1. ii os PERCOLATION RATE 6-0 (minutes/inch) TEST RUN BETWEEN FT AND �16— FT .Atr in, nn• tge PERFORMED BY: . e42 S CERTIFIED BY: 72.008 (6/79) DATE: ' ' 21 3 PERFORMED FOR: LEGAL DESCRI 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 yayvl% SS h � ILS LOG I MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST �Glc,m r7v6---n!q✓vybvouX SI i+y S9 y 9ro*A (C&S of Sa" cm 9yaY c�yauP�l q✓dU�( sl2e �'�ylr calffi✓ c(Ya � '.4 O� .. 1 or r� '• 9'! YJTlN••N/�,f/�• eroy C. Raid, Jr. No. 2251E ?ROFgSSIPNP�-� DATE PERFORMED: ///Qd�, =;u 2 6 Z Lit) 1,C'' 4 T f I w AIA) SLOPE SITE PLA WAS GROUND WATER Q ENCOUNTERED? IF YES, AT WHAT DEPTH? Q P Reading Date Gross Time Net Time Depth to Water Net Drop 3-3I y;1 n9 tA00 0 F vb q;1662 2a N,d 9t/7 V; �a I> PERCOLATION RATE �-� (minutes/inch) TEST RUR BETWEEN ._L FT AND FT ,a 9, ZIIA4rn -i.-,. rro 4" /2t. PERFORMED BY: 80(16/" S CERTIFIED 72-006 (6/79) DATE: z/ !9 -aJ �1 Mmlici afity \ Pt, H 6-650 s \ ANCHORAGE, ALASKA 99502-0650 "4'-` '1 (907) 264-4111 Anchorage TONY KNOWLE S, AAA YOR DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Permit #: 840726 day- n��v January 31, 1985 TO: Permit Applicant SUBJECT: Lot 10 Block 2 Southpark Subdivision #2 A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1984. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site sewer system, the original as -built inspection report and the yellow copy must be sent to this office for review and approval, and for documentation. If there are any further questions, please call this office at 264-4720. Sincerely, Keith E. Bandt, Supe visor Environmental Engineering Program KEB/ljw enc: Copy of Permit SLOP/0 5 7 � | . ` . ` ^ t-11LJt%0 ��F�e-2ht__ I -IF'V CJF� DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION ~ B25 L STREET, ANCHORAGE, AK 99501 264~4720 ' C3 M_E5 I -r EE: E3 IE --"W EE rR% F� FE r;� �-1 I -IF PERMIT NO: 840726 DATE ISSUED: 08/27/84 � APPLICANT: ADDRESS: LEGAL DESCRIP: LOT SIZE: MAX BEDROOMS: LANDMARK -VENTURE LTD P O BOX 111654 ANCHORAGE, AK 99511 345-4807 SUBDIVISION: SOUTH PARK #2 SECTION: 3 TOWNSHIP: 11N 27575 (SQ.FT" OR ACRES) 3 U]T: 10 BLOCK: 2 RANGE: 3W Listed below are the options available to you in designing your septic system. Choose the option that best fits your site. -T- F? too 04 10 1-1 EA01a FR 41 y4 DEPTH TO PIPE BOTTOM (FT") 4^0 4"0 4"0 GRAVEL DEPTH (FT") 7^0 0^5 3"5 TOTAL DEPTH (FT") 11"0 4.5 7^5 GRAVEL WIDTH (FT") 2.5 24.0 5^0 GRAVEL LENGTH (FT.) 59"0 46"0 89^0 ** GRAVEL VOLUME (CU"YDS") 41"0 40"9 66"0 TANK SIZE (GALS) 1,000"0 ** 1,000"0 ** 1,000"0 ** SOIL RATING (SQ"FT^/BR) 275 242 275 � ** GRAVEL LENGTH > 75 FT" REQUIRES MULTIPLE RUNS (NOT EXCEEDING 75 FT" EACH) ** TANK MUST HAVE AT LEAST TWO COMPARTMENTS ' -^- -- - - - - - - - - - - - - - - - - - - - - - -,- - - - - - - - - - - -- I certify that: 1" T am familiar with the requireients for.on-site sewers and wells as set forth by the Municipality of Anchorage (MDA) and the State of Alaska" 2^ I will install the system in accordance with all MOA codes and regulations, and in compliance with the design criteria of this permit. 3. I will adhere to all MOA and State of Alaska requirements for the set back distances from any existing well, wastewater disposal system or public: sewerage system on this or any adjacent or nearby lot" 4� I understand that this permit is valid for a maximum of 3 bedrooms and any enlargement will require an additional permit. , � IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE ELECTRICAL WORK MUST BE DONE BY A LICENSED ELECTRICIAN. SIGNED DATE: ----------------- APPLICANT:MARK-VENTURE LTD ^ \/ '1;:'-71-Y -. /ISSUEDBY DATE" / �J~l SOILS LOG MUNICIPALITY OF ANCHORAGE +,e DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 264.4720 SOILS LOG — PERCOLATION TEST PERFORMED FOR: -PA Pn/tne— DATE PERFORMED: '4 X LEGAL DESCRIPTION: Sr uT%1 P K 13/cam' 2 lot /Q %— D FT SLOPE SITE PLAN (FPE ) I OL dr.:�. m�rY r."i 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 -fQn 'Si#7 s=«!y y v c016Ie S COMMENTS WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? _ "'1'_ nom__ L n G S °% Reading Date Gross Time Net Time Depth to Water Net Drop -Z' .5 /a /Z53" L6 rGS Its Ky /e lyy ,G3 It3Yr-% G5 to fI ,od PERCOLATION RATE TEST RUN BETWEEN (minutes, 3 JZ FT AND FT I PERFORMED BY: MOA STfiY UZSC CERTIFIED BY: 72-008 (6/79) MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Parcel I.D. 020-501-33 Certificate of On -Site Systems Approval Expiration Date: Legal description SOUTHPARK #2 BLK 2 LT 10 Site address 15651 SOUTHPARK LOOP Anchorage AK Current property owner(s) ELIZABETH & WALBERT SCHULPEN X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: 2003 trenches had 10" of water in them, measured June 2023 By:U5 4" Original Certificate Date: Cy This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory X Arsenic Advisory Other COSA Approval—June 2022 MU M CUP U 11Y OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 020-501-33 Complete legal description SOUTHPARK #2 BLOCK 2, LOT 10 Location (site address) 15651 SOUTHPARK LOOP, ANCHORAGE, AK 99516 Current property owner(s) ELIZABETH & WALBERT SCHULPEN Day phone 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ® Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ® Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 20 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ® Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ S�V Waiver Fee $ Date of Payment 40 / zo z 3 Date of Payment r COSA # 05C 2 12- 3 Waiver # COSA Application.doc COSA Checklist.docx COSA Checklist Legal Description: SOUTHPARK #2 BLOCK 2, LOT 10 Parcel ID: 020-501-33 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA - PUBLIC &/OR CLASS “A” WATER Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume NA gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank *NA Date of pumping 5/24/2023 Required maintenance completed, if AWWTS Comments: *1500 STEP TANK C. LIFT STATION Required maintenance completed Age of lift station 20 years Lift station material STEEL Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 5/23/1988 ALL standpipes present per record drawing* Total measured depth from grade 3 ft (max) Measured depth to pipe invert from grade 3.2 ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective (ED). If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced 2000 gallons 6/21/23 date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 6/22/23 Results Pass Fluid depth prior to test 0 in Water added 800 gal New fluid depth 0 in Elapsed time <5 min Final fluid depth 0 in Absorption rate 650 gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 6 in Effective depth used 0 in Effective depth remaining 6 in Comments/Deficiencies: *A+ excavated - resurrected and extended buried bed septic pipes. 1988 bed presoaked and tested. The other field is marginally operating. Approximate total measured depths from existing grade – more cover over cleanouts. ED per elevation measured shots & appears approximate. COSA Checklist.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) - NA Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS Per MOA file – water service line is 10’+ from each absorption field. G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 08/30/2023 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 8/30/23 Septic Tank Advisory Certificate of On -Site Systems Approval # OSC231236 Subdivision: SOUTHPARK #2 Block:2, Lot: 10 The septic tank for this property is 20 years old. The average life of an asphalt coated steel septic tank is 20 years. Typical replacement costs are $10,000 or more, not including engineering, surveying or MOA permitting fees. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 30 year old steel tank MAY look like. f MaiUng Address P O Box 196650 *Anchorage, Alaska 99519 6650 *www muni org • •- _� Municipality of Anchor.t�• a '0 �� °?�� 8�, � On-Site Water and Wastewater Pro• j,� ��; 4 �V d i (907) 343-7904 `�' ' 5 A E T Y JUL 162018 Certificate of On-Site Systems !.s •roval Cu Parcel I.D. 020-501-33 Expiratio1 := L 13— le( 1. GENERAL INFORMATION Complete legal description Southpark #2, Block 2, Lot 10 Location (site address) 15651 Southpark Loop, Anchorage, AK 99516 Current Property owner(s) Allen Jefferey Day phone Mailing address 15651 Southpark Loop, Anchorage, AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Four 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual CI Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System Q Public Sewer ❑ WaiverNariance request for: Distance: Received by: //.1A0-11 c( P9lg Date: / 2L0/5/ COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 52L Waiver Fee $ Date of Payment .941(4 19)19) Date of Payment Receipt Number �0153c1 D Receipt Number COSA# r)60 J ` . Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone (907) 522-7773 Address PO Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 7/12/2018 pF A�,�Sil eco.. 6. DSD SIGNATURE Pl/tiaj, 044,e,Vr-/ j*:49 Tht /,‘ *� System #1 Approved for bedrooms Michael E.Anderson r ,•%. 4381-E • System #2 Approved for bedrooms ,ll�l.\\Es `� Disapproved Conditional approval for bedrooms, with the following stipulations: • OF A/V�;h,� ows W • Wp,TEE �ER • o WS1etPROL), 47-7 • rr qr0\\ By: Original Certificate Date: Z '—( The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: •�`:• l' COSA Checklist X Nitrate Pid?ripory, Septic System Advisory Arsenic-Ath isor . Well Flow Advisory Other •,c`` . COSA blue sheet_f c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Southpark #2, Block 2, Lot 10 Parcel ID: 020-501-33 A. WELL DATA Well type Public Water If A, B, or C provide PWSID# Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEP/Steel Date installed 6/16/2003 Tank size 1500 gal. Number of Compartments 3 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) Y Date of pumping i - I ' 1 8 Pumper Ar --time) \/(C'eS C. ABSORPTION FIELD DATA Date installed 6/18/2003 Soil rating (g.p.d./ft2 or ft2/bdrm) .45 GPD/SF System type Deep Trench Length 2 @ 56 ft. Width 3 ft. Gravel below pipe 6 ft. Total depth 8-9 ft. Eff. absorption area 1344 ft2 Monitoring tube Y Depression over field N Date of adequacy test 7/7/2018 Results (Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test 0/0 in. Water added 800 gal. New depth 21/19 in. Elapsed Time: 580 min . Final fluid depth 1/1 in. Absorption rate >= 600 g p d None Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed 6/16/2003 Size in gallons 1500 Manhole/Access(Y/N) Y "Pump on" level at 42 in. "Pump off' level at 38 in. High water alarm level at 44 in. Datum Bottom of Tank Cycles tested Three Meets alarm&circuit requirements? Y E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >1 00' On adjacent lots >100' Absorption field on lot >100' On adjacent lots >100' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer/septic service line >25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: >10'Building foundation Property line >5 Absorption field >5 >10' >10' >100' Water main Water service line Surface water Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10 Building foundation >10 Water main X10 Water Service line Surface water Driveway, parking/vehicle storage 0 Curtain drain None Noted Wells on adjacent lots X100' F. COMMENTS 611 Votive & 4t. L AL Sin fiD G. ENGINEER'S CERTIFICATION ��...b.",...-‘,..OFA I certify that I have determined through field inspections and A..74) .•• ,`Q • ' •S/r-1� review of Municipal records that the above systems are in �C . • 9 conformance with MOA COSA guidelines in effect on this date. %*.•49 TH /\ ..*-0, Engineer's Printed Name Michael E. Anderson, P.E. r��� ,� / IAe 7/13/2018 F •. Michael E.Anderson : �# s . •4381-E ••` � Date �' • � tkIF'PROFESSIONP4.� \\\\��~ COSA brown sheet 10-10-12.doc 9,9 ,„)._el) MUNICIPALITY OF ANCHORAGE {RJ�.11C 1 Phone: 9C7-3, . !QV-! Development Services Department ___ / Fax. + �• r 997 On-Site Water&Wastewater Section Lilt StationiPurnp Vault Maintenance Log Owner-- e 1 i pn Street Address_ Eo I Sz1ki-1.=xrK T- - PhaneSg5 c1 I l`%_ Legal Desc. 4 2 ,__c-YnLcrk-*t-}.rte.— PID Septic"anis; -sludge level Q� inches -Pumping: required yes. .0___,o -Pumping completed�y .r a Lattalatigill "1 1B-1g" -Pump basket cleaned Q -'1" -Effluent filter cleaned 6Z)-fisa -Control floats cleaned X, �--� -Proper float settings confirmed ( ILQ -Operation satisfactory ( Ar inl-atstem; -Dedicated electrical alarm circuit --o,1?'":',. no •Audible and visual alaxsn inside dwelling i• -Alarm system operation �facielY) Rpt Satisf QtQa Manhole Riser -Ground water intrusion at riser to tank connection yes >1Q -Ground water intrusion around pipe penetrations yes ^rte, -Ween hn►e fiinc?ional . ; ''r, -Manhole lid: Functional �y Q Insulated yX5 no I roperiy Secured C '- c2 Other -AU manufacturer required inspections and maintenance completed Fi. rio • Comments: Dataiatrinanr Technician t1 `� Lc - LI- 1:3211-_, Date of maintenance vV f O Company W 5�' �'_ C-r Signature___ - Data-J3 .: � I Veiling Address:P.0.Box 196650* Anchorage,Alaska 99519-6650*www.muni_or5i iii Parcel I.D. 020-501-33 hyo $y Municipality of Anchorage On -Site Water and Wastewater Program ' (907)343-7904 sa [rz Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Expiration Date: I a — 2:z — / `j - Complete legal description Southpark #2 13I1<2 Lt10 Location (site address) 15651 Southpark Loop Dr., Anchorage Ak. 99516 Current Property owner(s) Jason Roth Day phone Mailing address 15651 Southpark Loop Drive, 99516 Real Estate Agent Colin Roth Day phone 727-1911 2. TYPE OF DWELLING: I] Single Family (w/wo ADU) ❑ Duplex ❑ Multiple .Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual Fx I Individual Water Storage ❑ Holding Tank ❑ Community Class A Well 0 Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for:. Received by- i"` l Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $_ 14'1O— Waiver Fee $ Date of Payment L pp la Date of Payment Receipt Number CA0) GL C*jReceipt Number COSA# ��Je O�e 5Oo Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Pannone Engineering Services LLC Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone 6. DSD SIGNATURE _z System #1 Approved for bedrooms System #2 Approved for _ bedrooms Disapproved Phone (907) 272-8218 Date 12/31/12 Conditional approval for bedrooms, with the following stipulations: By: Zz d Original Certificate Date: 1-3-13 urn' nchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the r r entations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet f ', c If more than 1 septic system is on the lot: COSA Checklist # t of I Structure served by this system -t.-- Certificate Certificate of On -Site Systems Approval Checklist Legal Description: Southpark #2 BIk2 U10 A. WELL DATA Well type Community Date completed Total depth ft. Date of test Static water level If A, B, or C provide PWSID # A, ID#213475 Sanitary seal (Y/N) Cased to ft. FROM WELL LOG in Well production g.p.m. WATER SAMPLE RESULTS: Parcel ID: 020-501-33 Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) in. AT INSPECTION Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: Collected by: ft. B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 6/16/03 Tank size 1250 gal. Number of Compartments 2— Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Date of pumping 12/28/12 Depression over tank (Y/N) N High water alarm (Y/N) Pumper A+ Home Service NA C. ABSORPTION FIELD DATA Date installed 6/16/83 Soil rating (g.p.d./W or ftz/bdrm) 0.45 System type Trench Length 56/56 ft. Width 2.5 ft. Gravel below pipe 6/6 ft. Total depth '0.6111.0 ft. Eff. absorption area 1344 ftz Monitoring tube Y Depression over field N Date of adequacy test 12/27/12 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 24/12 in. Water added 610 gal. New depth 41/28 in. Elapsed Time: 1440 min. Final fluid depth 24/12 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed 6/16/03 Size in gallons 250 Manhole/Access (YIN) Y 'Pump on' level at 42 in. "Pump off' level at 42 in. High water alarm level at 44 in. Datum Bottom of tank Cycles tested 2 Meets alarm & circuit requirements? Yes E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer /septic service line Animal containment areas On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5+ Water main 10+ Water service line 10+ Wells on adjacent lots 200+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water Service line 10+ Surface water 100+ Curtain drain 50+ Wells on adjacent lots 200+ F. COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Steven R Pannone Date 12/31/12 COSA brown sheet -1 0-10-1 2.doc Absorption field 5+ Surface water 100+ Water main 10+ Driveway, parking/vehicle storage 110+ MUNICIPALITY OF ANCHORAGE • DEPARTMENT OF HEALTH i£ HUMAN SERVICES Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 ICIPALITY OF ANCHORAGE NMENTAL SERVICES DIVISION DEC 0 2 1991 CERTIFICATE OF HEALTH AUTHORITY RECEIVED APPROVAL FOR A SINGLE FAMILY RWELLING Parcel I.D. It oao —o5a _Sd HAA # 4Q- 9/06-,7.5- 1. 75 1. GENERAL INFORMATION Complete legal description LO i j 0 / 13tcck a SoLdh 41Y �t1cc�1JiSio�, ADD # 2 8WChnraa12- Location (site address or directions) )5(0_51 S LbOID Property owner JQs�>1 Day phone ab� 3b30 Mailing address 5 �5lAyk �6�_�(�1bYdL1� �L Lending agency Day phone Mailing address Agent Day phone Address Unless otherwise requested, HAA �(w�,illl be held for pickup. 2. NUMBER OF BEDROOMS: q / — 3. TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Ra, 1/91) Front MOA x21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I furtherverify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Address Engineer's signature y I Careyl`yn�� 4a1.,✓iP��°° # 353 6. DHHS SIGNATURE Approved for bedrooms. -- Disapproved. -- Conditional approval for bedrooms, with the following stipulations: AAVAA= Additional Comments 0 UJITIC Date 12 The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Fay. 1/91) Back MOA N21 Legal Description: A. WELL DATA Well type A Log present(Y/N)_ Totaldepth NAr Sanitary seal (Y/N) Date of test Static water level Well flow Pump level Municipality of Anchorage Department of Health & Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Parcel LD If A, B, or C, attach ADEC letter. ADEC water system number Date completed "�"© 't Driller NA Casedto Nb Casingheight NA' Wires properly protected (Y/N) NA FROM WELL LOG AT INSPECTION SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot 1" ; On adjacent lots NA - Absorption field on lot ASF( ; On adjacent lots A) A, Public sewer main AIA Public sewer manhole/cleanout Sewer service line Ne)- Petroleum tank Nd WATER SAMPLE RESULTS: Coliform Nk Nitrate Date of sample: B. SEPTIC/HOLDING TANK DATA Date installed 5-Z3-62 Cleanouts (Y/N) High water alarm (Y/N) Date of pumping tl116 h Other bacteria Collected by: Tank size I r3OO Compartments 2. Foundation cleanout (Y/N) Nk3 Depression (Y/N) Al - Alarm tested (Y/N) Pumper A �- liom� S'cr✓ c SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: r We] I(s)onlot IJ -4 4100 On adjacent lots NA +100 Foundation /Z To property line 30r Absorption field 25� Water main/service line ~2 5 r Surface water/drainage +150 72-026 (Rev. Bret) Front - CONTINUED ON BACK PAGE C. LIFT STATION r ANcrl tl}tf�C. Date installed 5 - 23 - es Manufacturer v A keWa vn Size in gallons S a a Manhole/Access (Y/N) or -.s It If Vent (YEN) Yes "Pump on" level at " `/Z "Pump off' level at -0 v�Z u High water alarm level "17 t/z- Cycles tested Meets MOA electrical codes (Y/N) YYs SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot )ac) f, On adjacent lots (Uo * Surface water N A . D. ABSORPTION FIELD DATA Date installed 5- 03 - 8-91 Soil rating 3 1 2N System type b eoi Length I? At Width Z° Gravel thickness o•5 Total depth Total absorption area 18$O 54. Cleanouts present (Y/N) YC -S Depression over field (Y/N) Date of adequacy test /I (L r- /q" Results (pass/fail) M55 for 4 DwVA6 bedrooms Peroxide treatment (past 12 months) (Y/N) - No If yes, give date SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot To building foundation _ On adjacent lots 57 Surface water NA - Curtain drain E. ENGINEER'S CERTIFICATION On adjacent lots Property line /01 To existing or abandoned system on lot utbank NA Water main/service line Driveway, parking/vehicle storage area — 1 certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. f Signature Engineer's Name Y elE� Date r Care) s. Mc rr , - a'G3 'u HAA Fee $ _ ta' Waiver Fee: $ Date of Payment t % Date of Payment Receipt Number 2�6-z o L cy l i Receipt Number 72-026 (Rev. 3/91) flack MOA 21 WALTER J. NICKEL, GOVERNOR DEPT. OF ENVIRONMENTAL CONSERVATION r ANCHORAGE DISTRICT OFFICE I 563-6775 3601 "C" STREET, SUITE 322 ANCHORAGE, ALASKA 99503 FOR: Ken Ackerman November 18, 1991 PWSID # 213475 My review of the records on file in this office reveals that the South Park Subdivision Class "A" Public Water System, is in compliance with the routine coliform bacteria samples requirements listed in Table C, and with the inorganic sampling listed in Table B of 18 AAC 80.200. Sincerely, f5t�/" / V"/i( Byron Roys Environmental Engineer BR/cf �-119 pnntc!I on recycled paper by O MUNICIPALITY OF ANCHORAGE • Department of Health & Human Services M t DIVISION OF ENVIRONMENTAL SERVICES 343-4744 CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING Parcel I.D.# OZQ-619-8y HAA# K—L SS 1, GENERAL INFORMATION (Must be completed prior to submittal) (a) Legal Description (include lot, block, subdivision, section, township, range) -,r+, ,/ r% EG j L6T 10 , 3 ex 4-'= so*, 7.w Al- Z-- T S ,ei n (address'or.directions) y 'e. vl �.48,C Lea�.y. (b) Property 6wner- Tu�/zx'"'✓JT. Telephone: (home) Business Mailing Ai3dress. --D$tX 3�k (c) Lending Institution_��� ' .�T/O/1/69 G Telephone ALLC`— Mailing Address (d) Real Estate Company and Agent Address Telephone (e) Mail the HAA to the following address: (or check here , if hold for pick up,) List contact person and day phone number below: 2. TYPE OF RESIDENCE Single -Family Number of bedrooms 3. WATER SUPPLY Individual Well ❑ Community( Public ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to th legality and status. 4. SEWAGE DISPOSAL On-site'X, Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legailty and status. 72-025 (Rev. 7/8B) Page 1 of 2 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional .and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm /� Tele/phone X79 -SSS) Address /Yly fi 0/� Ax g5rej Date • LER C. REID, JR. ITrleer' X151 �,� w 6. DHHS APPROVAL Approved for%bedrooms by y/ ` Date Approved 0 � Disapproved Conditional Terms of Conditional Approval CAUTION. The Municipality of Anchorage Department of Health and Human Services (DH HIS) issues Health Authority Approval cerificated based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72025 (Rev. 1/88) Back Page 2 of 2 • MUNICIPALITY OF ANCHORAGE (MOA), Health Authority Approval (HAA) { CHECKLIST - FEBRUARY -4984 U;�.. 343--4744 A. WELL DATA Well Classification vv;v,V_0 Orth LQgp�Description: L Tie X/1�L Ssn7A� �i�hek 41/Z C001/1 Log Present(Y/N) Cased to Static Water el Casing Height Abov ound — Electrical Wiring in Conduit SEPARATION DISTANCES FRO To Septic/Holding Tank on Lot _ sib Ti/.J Z30J 36?- 3 If A, B, C, D.E.C. Approved&N) Date Completed Depth of Grouting To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line To Nearest Sewer Service Line on Lot Water Sample Collected by Water Sample Test Results Comments Aays Yield Pump Set At . Sanitary Seal on Casing (Y/N) — Depression Around Wellhead (Y/N) On Adjoining Lots ; On Adjoining Lots To Nearest�kublic Sewer Cleanout/Manhole ; Date B. SEPTIC/HOLDING TANK DATA Date Installed �y3Size /Sda No. of Compartments Standpipes ON) Air-tightCaps(N) Z Foundation Cleanout N) Depression over Tank (Y/6 Date Last Pumped /�4 Pumping/Maintenance Contact on File (Y/N) —A/* ; for �✓�� Holding Tank Hjgh Water.Alarm (Y/N) Temporary Holding Tank Permit (Y/N) SEPARATION,DT$TANCES ROM SEPTIC/HOLDING TANK: To Water Supply Welk { �tl �'� To Building Foundation 9� ., .'.:.. J To Property Line � ' 30 To Disposal Field To Water,Main%Service Line:, a � To Stream Pond; Lake or Major Drainage Course Comments 72-026 (Rev. vae) Front Page 1 of 2 G.io az s.?ileo, of- z C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Sz3-88 3 /Z Type of System DesignD Length of Field Width of Field ZO Depth of Field / - 3 Gravel Bed Thickness D S Square Feet of Absortion Area /8po Statndpipes Present (N) //.. Depression over Field (Y,© Date of Last Adequacy Test Results of Last Adequacy Test ��/R SEPARATION DISTANCE FROM ABSORPTION FIELD: r i To Water -Supply Well To Property Line /o i To Building Foundation To Existing or Abandoned System on Lot eo ; On Adjoining Lots i To Water Main/Service Line To Cutback (if present) �✓ To Stream, Pond, Lake, or Major Drainage Course ZOO To Driveway, Parking Area, or Vehicle Storage Area /o Comments D. LIFT STATION Date Installed S 7,3 -9,T' Dimensions /Z X T Size in Gallons /fot7 Manhole/Access Y/ ii ) i ?� "Pump On" Level at - ��41 "Pump Off' Level at �D�i High Water Alarm Level at ell Vent(ON) Tested for owe Pumping Cycles during 1___ 1 ili- t• Meets MOA Electrical Comments "Check Permitted Bedroom Rating Against HAA Request" -r Aim 5r4 ewh6o . I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed GG!—t� lN�- ®� 1* � p• _ Company AGS �•`�°,ee.A4 �� : .�e'� b�® Date — 9-% �4g7"e,°°e° $neer'sSeal MOA No. / 0�f s � �e •°eov°• a ne°°na •.. j IE C. REID, JR. FF A®4c� �Recei U�rPy�1�0 0 No. t No.Receipt Receipt Date of Payment / Waiver Fee: $ C) c) Amount: $ / / U Date of Payment 72-026 (ROV. ]/88) Back Page 2 of 2 INSPECTION REPORT MUNICIPALITY OF ANCHORAGE, BUILDING SAFETY DIVISION 3500 EAST TUDOR ROAD IKIQ0PrTInNA /onn AAA-aaea INFORMATION (907) 786-8211 i � � � �• ' OO NOT REMOVE THIS NOTICE M -W2 (Rm 11/87) t C NAME ('•� -: �. �%. PERMIT NO. - -3 3 STREET ADDRESS - '/PHONE- % I I I - LOT / BLOCK /"?/ SUBDIV.—" ' / DATE FOOTING ❑ ELEC. TEMP. ❑ PLBG. UNDGR. — ❑ FOUNDATION ❑ ELEC. SERVICE ElPLBG. ROUGH — ❑ BOND BEAM ElELEC. ROUGH ❑ GAS TEMP. ❑ FRAMING 11ELEC. FINAL EJ/ GAS ❑ - INSULATION ElOTHER ElMECHANICAL ❑ SHEETROCK 1-1MECH. FINAL ElSTRUCT. FINAL EJFIRE FINAL ElPLBG. FINAL ElOTHER tElZONING ElOTHER ❑ O NO NONCOMPLIANCE OBSERVED CORRECTIONS ESSENTIAL AS - \EXPLAINED BELOW WILL REEXAMINE AT NEXT INSPECTION ❑ DO NOT CONCEAL UNTIL REINSPECTED COMMENTS / f J INSPECTOR DATE WHEN CORRECTIONS ARE MADE, PLEASE CALL FOR INSPECTION Q AfA-t j/f�STEVE COWPER, GOVERNOR 'IfAAJIS [ DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE/WESTERN DISTRICT OFFICE 563-6775 3601 C STREET, SUITE 1334 ANCHORAGE, ALASKA 99503 DATE: August 31, 1988 PWSID: 213475 To Whom It May Concern: According to the records on file in this office, the SOUTH PARK TERRACE SUBDIVISION Water System is in compliance with the State of Alaska Drinking Water Regulations. Sincerely, i ,t�-- Michael/p- Lewis, PE Environmental Engineer NPL:pkk , , OQ / �O AQP J� 1:1O LOT 10 / 23,575 sq. ft. Cb / O - ry�'ry. / 25' ASPHALT DRIVEWAY N /C\j REBAR W/CAP wo j LOT 11 SEPTIC MANHOLE �J Ci? CO 175 3.1 C\i 3.8' STONE PAVERS zo CANT. 0 r\ o CAN -r. x-3 8.0' 40.2, — 2 -STORY FRAME HOUSE O 1.4' N 85°25'02" E 178.50' SEPTIC STANDPIPES � LEJ REBAR ELECTRICAL TRANSFORMER LOT 9 �i *:49TH *; ............................. 0 15 30 % B u Sahz LS -14837 = • 5 — rf 1lt1�OO ESS II���P``� \` EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED SUBDIVISION PLAT (83-213) ARE NOT SHOWN HEREON. THIS DOCUMENT DOES NOT CONSTITUTE BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR ESTABLISHING PROPERTY BOUNDARIES. THIS SURVEY REPRESENTS A MORTGAGE LOCATION SURVEY PREPARED IN ACCORDANCE WITH THE ASPLS MORTGAGE LOCATION SURVEY STANDARDS. THIS MORTGAGE LOCATION SURVEY SHOULD ONLY BE USED FOR A SINGLE PROPERTY TRANSACTION. RE -USE OF THIS DRAWING BY THE ORIGINAL CLIENT OR BY OTHERS, FOR ADDITIONAL USES ATA LATER DATE WITHOUT EXPRESS CONSENT OF THE SURVEYOR ISA VIOLATION OF FEDERAL COPYRIGHT LAW. UNLESS GROSS NEGLIGENCE IS DISCOVERED, THE LIABILITY EXTENT OF THE PREPARER SHALL BE LIMITED TO THE AMOUNT OF FEES COLLECTED FOR SERVICES IN PREPARATION OF THIS PRODUCT. JOB # 23116 I NO CORNERS SET THIS DATE I SCALE 1" = 30' AS -BUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: LOT 10, BLOCK 2, SOUTHPARK SUBDIVISION ADDITION No. 2 ANCHORAGE RECORDING DISTRICT, ALASKAAND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST EXCEPTAS INDICATED. DATED THIS 28th DAY OF JULY, 2023, AT ANCHORAGE, ALASKA. FIXED HEIGHT, LLC C.O.A.122554 Land Surveying Services 907.290.8949 225 VV 23rd Ave., Anchorage, AK 99503 WWW.FIXEDHEIGHTCOM i O¢ cA Lot 11 Septic vent • j q ,ry Septic vent J � � O� co ry• o en '"-- Septic vent. CP As 40 .0 h -Septic vent 2StoryFram �v f 7.5 otrs e 30 .2 OH o e H O 1.5 3.8 o 2.0 OH I LOT 10 14.3 �g m o o a ma.o 2.00 z.a t A N5°25'02"E 178.50 t Lot 9 25 Note: Asphalt & concrete is approximate due to snow and ice - OF 4 ce. OF,4 1 � EASEMENTS OF RECORD. OTHER THAN THOSE SHOWN ON THE RECORDED PLAT ARE NOT SHOWN HEREON, Fb 12-8, pg 54 BE 8377Q SCALE: 1"= 40' l �asemet< Lot 13 �F � s N' f AS -BUILT NO CORNERS SET THIS DATE I hereby certify that I have performed a Mortgagee's inspection of the following described property: LOT 10 BLOCK 2 _SOUTHPARK SUBDIVISION ADDITION No Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Andmragc, Alaska this 14th day of December ,2012 FRED VVALATKA& ASSOCIATES (907-248-1666) Engineers and Surveyors