Loading...
HomeMy WebLinkAboutSOUTHPARK #2 BLK 3 LT 26 (~--~ MUNICIPALITY OF ANCHORAGE /" RTMENT OF HEALTH AND HUMAN SE ,ES Environmental Health Division 825 "L' Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Name DISTANCES Add .... 5~¢ec¥. Eo,.qp,,.~,,j g~.?ld~.~ ~ SEPTIC ABSORPTIO~ WELL ~ ~ ~or~ ~r~ P~& ~ ~ ~ ~,_~ ~ ~ TANK FIELD Permit NO No. et ~ed~ms LOT LINE -- ~ ~<~ ~ AS-BUILT .lAG.AM (Show mocatmo, o, well. ~eptic system, property mines. ,oundat .... ~ ~ ~_ "~ ~L[ J~ ~~'.~J~,~ ~· · drweway, water bodies, TANKS ~SEPTIC ~ HOLDING *,{ ~ / I TYPE OF SYSTEM ~ ....... ~ TRENCH ~' BED U W, DRAiN U OTHER ...... onginal grade /t ~'- '~ ~/, J ~ FT ~ '~ ~ Fl ' ' FHI added above odgmn~l grade ~rave, depth beneath pmpe % To,al abs4,,o~ .... Distance%et .... mine, 6 ~'TSgFlj ~ ~SO~V WELLS ~ PRIVATE ~ OTHER ,Identify) REMARKS: I ~>~-¢~ ~/--' ~ ceflJfy that this in~pection was pedormed according lo all ~unicipal ~nd St~te~idelines in e[~ : ~ ~ / ~ - ~ J '~ 72-013 (3/85) DEF:'ARTMEiqT JIF HEAl_TH AIqD ENVIRONMENTAL. F'ROTECTION 8~5 L STREET, ANCHGRAGE, AK 99501 ' ~64.-4'7R0 C}N--E~ Z TE ~SEZD~ZR F'EF~ I T PEi::d'l I T Iq[): DATE ISSUED: 07/30/I]5 APPL I L']AIqT: ADDRESS: CONTACT I::'H 0 NE ." SCHRECK CO BLJILDERS 2640 IVORY DRIVE ANCHORAGE, AK 99516 345-5415 LEGAL DESCRIP: LOT SIZE: LGT LGCATtON: MAX BEDROOMS: 8UBDIVISIGN: SOIJTH PARK] ~ LOT: 26 SECTION: 3 TOWNSNIP: :LIN RANGE: 3W ~4894 (SQ. ET. OR ACRES) STANWOGD CIRCLE 4 BLOCK~ 3 Listed below are the options available t.o you in designing your septic system.. Cheese the option thai. best fits your site. BLED DEP'I'H T8 PIPE BOTTOM (FT.') 1.5 e~' GRAVEL. DEPTH (FT.) 0.5 TGTAL DEPTH (FT.) R.O GRAVEL WIDTH (FT.) ~9.0 ,~' GF(AVEt... LENG'/H (FT.) 58.0 ~: . GF~AVEI._. VOLUME (CU. YDS. ) 6~. 3 TANK SIZE (GALS) 1,250.0 e'[' GOIL RATING (SQ.FT./BR) ~77 ~ 1]}~A ][ N 1.5 1.5 3.0/' 5.0 210.0 ~'* 77.8 1,250.0 ** ' 33'7 ~'~ DEF'TH TO PIPE BO'fTOM < ~.0 I--T. REQUIRES ADDITIONAL GROUND COVER e~ DEPTH TO PIPE BOTTOM < 3.5 FT. REQUIRES INSULATION '~'~- DEPTH TO F'IPE BGTTOM < 4.0 FT. MAY REG!UIRE A LIFT STATION · ~ GRAVEL LENGTH > 75 FT. REI~UIRES MULTIPLE RUNS (NO]' EXCEEDING 75 FT. EACH) ~ TANK MUST HAVEE A]~ L. EAST TWO COMPAF~TMENTS I certify that: 1. I am familiar with the requirements £er on-site Sewers and wells as set For'th by the Municipality oF Anchorage (MOA) and the State oF Alaska. 2. I will i'nstall the system in accordance with all MOA codes and regulatiens~ and in compIiance with the design criteria oF th:is permit. · 3. I will adhere to all MOA and State of Alaska requiremen'Ls ~or the set back distances From any existing well, wastewater disposaI system or public sewerage !system on this or any adjacent or nearby lot. 4. I unders'Land that this permit is valid for a maximum oF 4 bedrooms.and any enlargement will r. equire an additional permit. IF A L. IF'I' STATION I8 INSTALLED IN AN AREA COVERED BY MOA BLIILDING CODES, THEN ¢].) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (R) A,.~-BUILF~ WII..L. NOT BE APPROVED WITHOUT APl ELECTRICAl_ INSPECTION REPORT~ ~:~ND (3) ]'HE ELECTRICAL. WORK MUST BE DONE BY A LICENSED ELECTRICIAN. DATE: SIGNED ............. P%)PL I CAN]": .... Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST DATE PERFORMED: (ENGINEER'S SEAL) LEGAL DESCRIPTION: 1 2 3- 4- 7- 8- 9- 10- 13-, 14- 15- 16- 17- 18- 19- 20- Township, Range, Section: SLOPE SITE PLAN S L DEPTH? p Depth to Water ADer Monitoring? . Date: MUNICIPALITY OF ANCHOP~Gf DEPT. OF HEALTH & Gross Net Depth to Net Reading Date Time Time Water Drop ENVIRONMENTAL PROTECTION OCT j RECEIVED PERCOLATION RATE ~ 6~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ,~L FT AND '~l~' FT ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: po U/~'~ 6_650 ANCHORAGE, ALASKA 99502-0650 (907) 264-4111 TONY KNOWLES. MA YO Fl DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Permit #: 840323 January 31, 1985 TO: Permit Applicant SUBJECT: Lot 26 Block 3 South Park //2 Subdivision A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1984. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site sewer system, the original as-built inspection report and the yellow copy must be sent to this office for review and approval, and for documentation. If there are any further questions, please call this office at 264-4720. Sincerely, rKeith E. Bandt, Supe~viso Environmental Engineering Program KEB/ljw enc: Copy of Permit SWP/057 MUNICIPALITY OF ANCHORAGE DEPARTMENT OE HEALTH BND ENVIRONMENTAL PROTECTION 825 L STREET, ANCHORAGE, AK 99501 PERMIT NO: DATE ISSUED: C~-~--SITE SE~.~E~: ~: ~JELL PERMIT ' 05?09?84 APPLICANT: A,M.C. INC. ADDRESS: P .0. BOX 4-2882 ANCHORAGE, AK 99509 CONTACT PHONE: ~45-5815 LEGAL BEdE. RIP. SUBDIVISION: 'SOUTH PARK SECTION: 5 TOWNSHIP: LOT SIZE: ~0000 (SQ. FT.. OR ACRES) MAX BEDROOMS: 4 LOT: 26 RANGE.: ~W BLOCK: LISTED BELOW ARE THE OPTIONS AVAILABLE TO YOU IN DESIGNING YOUR SEPTIC SYSTEM. CHOOSE THE OPTION THAT BEST FITS YOUR SITE, TP, E~-tCH BE[) DEPTH TO PIPE BOTTOM (FT.) 4. 0 4. 0 GRAVEL DEPTH (FT.) 4, 0 0.5 TOTAL DEPTH (FT.) 8.0 4. GRAVEL WIDTH (FT.) 2.5 26.0 GRAVEL LENGTH (FT.) 116.0 ** 51.0 GRAVEL VOLUME (CU. YDS. ) 48.5 49. i TANK SIZE (GALS) 1,258.8 SOIL RATING (SQ. FT.?BR) [.,~_ 4.0 2.5 7.5 5.0 'iO0. 0' ' 74.0 t., 250. 0 25-4"1 GRAVEL LENGTH > 75 FT. REQUIRES MULTIPLE RUNS TANK MUST HAVE AT LEAST TWO COMPARTMENTS (NOT EXCEEDING 75 FT. EACH) CERTIFY' THAT: i. I BM FAMILIAR 2. 5; WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE (MOA) AND THE STATE OF ALASKA. I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH ALL MOA CODES 8ND REGULATIONS, AND IN COMPLIANCE WITH THE DESIGN CRITERIA OF THIS PERMIT. I WILL ADHERE TO ALL MOA AND STATE OF ALASKA REQUIREMENTS FOR THE SET BACK DISTANCES FROM ANY E~ISTING WELL~ WASTEWATER DISPOSAL SYSTEM OR PUBLIC SEWERAGE SYSTEM ON THIS OR ANY ADJACENT OR NEARBY LOT. t UNDERSTAND THAT THIS PERMIT IS VALID FOR R MAXIMUM OF 4 BEDROOMS AND ANY ENLARGEMENT WILL REQUIRE AN ADDITIONAL PERMIT. IF A LIFT STATION IS INSTALLED IN RN RRER COVERED BY MOA BUILDING CODES, THEN (i) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND <5) THE SIGNED ............... 8PPLICRNT': *7~:E~'~-~--7/~ ..... MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION B2B L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: OL 2 3 ~1 4 5 6 7 8 9 10 11 12 13 DATE PEREO.MED: Ad~'F,'on ¢/-2 SLOPE SITE PLAN ,/ WAS GROUND WATER /V~/O S ENCOUNTERED? P E IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop u o 'z -- .~ ~ - i/~ ~1 ,~ PERCOLATION RATE (minutes/inch) TEST RUN BETWEEN ~..'/.~ FT AND '~ FT 2~ / 21 ~ ~7' lX ~ -~ , ~_ 14 15 17 18 20- COMMENTS rm%d ~ PERFORMED BY: 72-008 (6/79) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 82S L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SOILS LOG ~ [~PERCO LATIO N TEST PERFORMED FOR: DATE PERFORMED: ~"~' c~~') '~'~-~ LEGAL DESCRIPTION: G fa/'$ vj SLOPE SITE PLAN 10 11 13- 14- 15- C. Reid, Jr, 2{ 2251-E ~ COMMENTS I PERFORMED BY: WAS GROUND WATER /j~(~ I~ ENCOUNTERED? O P E IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop / ,' , +/60 I0:1 g.. z/ ~l '~/ff _~o ; ./~ PERCO LATIO N RATE ~ ~7/~¢~ (minutes/inch) TEST RUN BETWEEN ~-~ , FT AND *.~, 5 FT MUNICIPALITY OF ANCHORAGE DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION ~PPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE 1o General Information Application Date (a) Legal Description (include lot, block, subdivision, section, township, Location (address or directions) range) (b) Applicants Name Applicants Address (c) Applicant is (check one) Lending Institution Buyer ~ ; Other ~--~ (explafn); (d) Lending Instftut~on . Address Telephone - Home Business ~Y ~'~ ~ ; Owner/bultdgr~ -' Teleph_._one (e) Real Estate Coo & Agent Address Telephone (f) Mail the HAd to the following address: 2. Type of Residence Single-Family~ Multi-Family~ Other (describe) NUmber of Bedrooms _ 3. Wate~ Supplz~ Note: If community well system~ must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. Sewage Disposal 0nsfte~ Public I ] Community~--~ Holding Tank~--] Note: If community well system, must have ~£itten confirmation from the State Department of Environmental Conservation attesting to the legality and status. [Page 1 of 2] ~ngineeri~g Firm Providing Inspections, Tests, File Search~ Data and Info~ation As certified by my seal affixed hereto and as of the validation date sho~ below, I verify that my investigation of this Health ~thority Approval shows that the on-site water supply and/or wastewater disposal system is safe, f~ction~ and ~equate for the number of bedrooms and type of structure indicated herein° I further verify that, based on the information obtain~ from the ~nicipality of ~chorage files and from my investigation and inspection, the on-site ~ter supply and/or ~stewater disposal system is in compliance ~th ~1 Municipal and State codes, ordinances, and regula- tions in effect on the date of this inspection. Name of Firm Address Date (ENGI~E~ S~) DHEP Approval Approved for ~-~bedrooms Approved ~ Disapproved Terms of Conditional Approval Conditional CAUTION TIlE bCONICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIROMb~NTAL PROTECTION (DHEP) ISSUES ttEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT- ATIONS GIVEN IN PARAGRAPH 5 ABO~E BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO pURCHASERS OF HOMES ~ND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL ~ND STATE REQUIRE- b~NTSo Ei~PLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA ,BEFORE A CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK~ RR4/ej/D18 [Page 2 of 2] (DMEP SEAL) 7-19-84 MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal Description: MUNICIPALITY OF ANCHORAG(~ DEPT. OF HEALI'H & ENVIRONMENTAL PROT£CTION RECEIVED ..Y,,~ ¢, $ A. WELL DATA eification IfA, B, C, D.E.C. Approved (Y/N) ¥e.5 sent (Y/N) Date Completed Yield~.~/ Total Depth'~ Cased to Depth of (3routing Static Water Level~ Pump Set At / Casing Height Above Grou~d~n ~ Sanitary Se/..~asing (y/N) ~le;C~rria~ialonW~is;ga in~eOs~rnodmUit;~il~) ~'-~.~~~ep.~es~ion Around Wellhead (Y/N) To N~l;r::to:t~iaCnSh;l~r L.~/ To Nearest SewerT° Nearest ~n Lot_ Water Sample Co~y . · Date '"'""~; Date ~ Water Sa~st Results B. SEPTIC/HOLDING TANK DATA Date Installed Standpipes (~) Depression over Tank (Y/~) Pumping/Maintenance Contract on File (Y/N) Holding Tar~k High-Water Alarm (Y/N) Separation Distances from Septic/Holding Tank: To Water-Supply Well 2..00 To Property Line II ' To Water Main/Service Line G r- Course Er Size /Z ~,"O No. of Compartments ;~' Air-tight Caps ~.~N) Foundation Cleanout ~)N) Date Last Pumped /¢~' ~,- A- ; for z/,4 f¢/~ Temporary Holding Tank Permit (Y/N) /CA To Building Foundation /-~ ~ To Disposal Field ~ /4 ' To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 72-026(11/84) .!~ .. C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed ¢/- /4 Width of Field ,Z ~ 2. '7 -~ ~' //~-., Type of System Design Length of Field ,5-~, Depth of Field ,Z ' Gravel Bed Thickness ~" Square Feet of Absorption Area /~ ~2, Depression over Field Results of Last Adequacy Test Separation Distance from Absorption Field: To Wate?Supply Well G /- 2_oo ' To Building Foundation ' /2. Lot A/.A To Water Main/Service Line ~ r'- lo ' To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments Standpipes Present Date of Last Adequacy Test To Property Line /5~ To Existing or Abandoned System on ; On Adjoining Lots ~o ~ 4 To Cutbank (if present) D. LIFT STATION Date In~talled_.~ Size in Gallons ~'- "Pump On" Level at -~ ...... . High Water Alarm Level at Tested for Electrical Codes (Y/N) Comments Dimensions Manhole/Access (Y/N) "Pump Off" Level at __~..~ Ve n t~(_yZN)~.-~--~'~'~'' ,--~'~ u~p~ng-~uring Adequacy Test. Meets MOA ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I~h?e checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed ~/~"~' ~'"¢¢'~ 4¢~z/'~'~¢"~ Date ¢ - 'z. ~ ' ~ ,- Company ~¢¢ /n,~, MOA No. ~ ~S'¢~y Receipt No. ~ ~% ~%'¢~ 7% Date of Payment /0 ~//~5~ Amount: $ ~ ~ Page 2 of 2 72-026 (11/84) ALASKA Department of Health and Human Services 825 L Street/Suite 4 Anchorage, Alaska 99503 eIiOIROIlmeF/TAL COBTROL SeRuICE!S, If/C. ~nqinccrinq 6 [nuironmcnl~J Studies MUNICIPALITY OF ANCHORAG,'= DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION September 20, 1985 1 I 1985' RECEIVED Dear Susan: This is in regards to South Park Addition #2, Block 3, Lot 26. Recently, I did an inspection on this lot, in which they were going to install a bed. Prior to construction, I met Steve Schreck on the lot, to discuss how to place the bed. I stressed to Steve that there were two district soil stratas on the lot -- according to the soil log, a nice sandy silty gravel from 1 to 4 feet and a denser siltier soil from 4 to 12. They had dug another test hole hoping to find better soils, but instead it matched the soil log. I showed them how the layers differed distinctly -- the good soil was light, loose, and flaky, sloughing to the touch. The soil deeper than this was tighter, not as sandy, with more silt. I explained to Steve that the most important thing on this lot was to not accidentally dig through the good soll -- that they must have 2 feet of the good soll beneath the bed. Well., the next day they had me come up to inspect the bed system, and wouldn't you know it, they had dug down 5 feet deep at the east end of the bed and 2 feet at the west end (the lot slopes and they were keeping it level.) At first, I was very angry at them for ignoring my advice, so I went out to the truck and got my post hole digger to dig a hole about two feet deep in the extreme NE corner of the bed, intending to show them that they wdre in the wrong soil and had ruined the lot. However, to my surprise, the light loose sandy soil continued beneath the bed -- apparently, it got deeper in that direction. I chose to use the post hole digger, because that way I could make sure they weren't tricking me by putting fill type material in the bed in place of the tight soil, because I am very aware of the different feel of digging through fill as opposed to natural soil. Steve then told me that they had checked the soil in that corner to make sure they would still be in good soil, since he really is nervous about shallow beds and wants his septic systems as deep as possible. At any rate, the point is, this bed is built entirely in a nice sandy silty gravel soil, which I have confirmed in the field. If you have any questions, please feel free to call. Sincerely, Darcy~vens Engineering Geologist Lgroy C.~Reid Jr., PhD, P.E. President~ 1200 [Uesl 33rd Aucntm, SuJle E~ ~, Anchoroclc, Alaska 99503 ,(907) 561-5040