Job No. 5941
BESSE, EPPS POl-rS
Engineering, Planning & Surveying
2220 E. 88th Ave.
Anchorage, Ak. 99507
Telephone (907) 349-6451, 344-1352
June 24, 1981
MUNrCIPALffY OF ANCHORAGE
DEPT. OF HEALI'H &
FNVIRONMENTAL PROTECTION
State of Alaska
Department of Environmental
437 E Street, 2nd Floor
Anchorage, Alaska 99501
Conservation
J'.N 2 9 1981
RECEIVED
Attention: Mr. 'rom Murrell
Dear Mr. Murrell:
Subject: Proposed Infiltration Gallery to serve Southpark Subdivision
Attached please find a copy of the proposed location of the infiltration
gallery to serve Southpark Subdivision which we discussed last week. It is our
intention to construct the gallery this week and begin test pumping and monitoring
of water quality upon completion.
As we discussed, the final design will depend upon amount of water and actual
field conditions encountered. As-builts of the gallery will be submitted upon
completion.
Actual usage of the water from the gallery will probably not occur until
next year. During this time, monitoring, testing and final design of the pump
house and distribution system will be taking place.
If you have any questions or desire additional information, please advise.
DAG/jl
cc: John Lynn, DHEP
John Berggren
June 30, 1980
338 Denali Street
Macl(ay Bldg., Room 1206
Anchorage, Alaska 99501
(907) 274-5527
P.O. 8ox 1207
Soldotna, Alaska 99669
(907) 262-5210
P.O, Box 1064
Wasilla, Alaska 99687
(907) 376-5038
18-06LH
Department of Health and
Environmental Protection
Municipality of Anchorage
825 L Street
Anchorage, AK 99501
Attention Mr. John W. Lynn
MUNICIPALITY OF ANCHORAGE
ENVIRONMLNi'AL ~,,©i~CTION
JUl. :[ 1980
RECEIVED
Subject: South Park Water System
Dear Mr. Lynn:
We have reviewed the preliminary plans for the proposed Southpark
Subdivision, phase I (23 lots). We hereby give our conceptual ap-
proval for the use of well #1 in conjunction with 87 gallon hydronu-
matic storage tanks in each home for use as an initial water system.
Our comments follow:
(i)
Our calculations show that the proposed system will meet
the minimum water requirements for the 23 homes proposed
in phase I. Experience however, has shown that when sub-
divisions are built around small yield wells that are pumped
at or near their rated capacity, water shortages will occur
in the future. Well yields nearly always drops with time.
(2) A centralized water storage tank is usually preferable in
the long run as opposed to individual storage tanks.
(3) Fire protection under the proposed system will be limited.
(4)
Expansion of the subdivision beyond 23 houses under the pro-
posed system will be severely limited without additional
water from another source.
In reviewing this project we noted that the percolation tests conducted
within the subdivision were not in accordance with the U.S.D.H.E.W.
Department of Health & page 2 June 30, 1980
Environmental Protection
Manual of Septic-Tank Practice. Results from these tests may not
accurately determine the suitability of the soils for the use of septic
systems.
If you have any questions concerning our conceptual review of this
project, please fee]. free to contact me.
Tom Murrell
Environmental Engineer
cc:
imc
David A. Grenier
Tryck, Nyman & Hayes
NYMAN
Street Anchorage, Alaska 99501 /907 279-05
Cable TNHANCAK/Telex 090-25332
8171.0
June 20, 1980
Department of Health & Environmental Protection
Municipality of Anchorage
825 "L" Street
Anchorage, AK 99501
Attention: Mr. John W. Lynn
Subject: Sou~hpark Subdivision
Dear John:
In response to your letter dated June 17, 1980, regarding the
proposed subdivision plat for Southpark, the following additional
information is submitted:
Item No. 1---Lot 4, Block l: An additional soils test was taken on
this lot located within the proposed drain field. This additional test
answers the concerns expressed about this 'lot.
Item No. 2.--Lot l, Block 3: A soils test was also taken on this
lot in the revised proposed drain field location.
Item No. 3: The drain field location for Lot 2, Block 3 has been
revised as recommended. (The existing cut bank will be to a minimum of
2 to 1 or less.)
Item No. 4: The drain field for Lot 3, Block 3 has also been
revised as recommended.
Item No. 5: Please regard this letter as acknowledgment for the
need of proper abandonment of the existing wells within Phase I. This
will be accomplished as per DHEP requirements within the next six to
eight weeks.
Item No. 6: The design of the water system to serve Phase I is
nearing completion and will be submitted to the State Department of
TIRYG(
NYMAN
"2-
Mr. John W. Lynn
June 20, 1980
8171.0
Environmental Conservation as well as DHEP for review and approval.
Attached, please find a letter addressed to the Municipality of Anchorage
Planning Department dated June '16, 1980, regarding the water system and
supply as it is being designed to serve this first phase.
Also attached are copies of the additional soils tests that were
taken which included Lot 2/3, 4 and 7 of Block 1 and Lot 1, Block 3. If
there are any further questions or if we may provide additional information
at this time, please advise.
Very truly yours,
cbh
Attachments: As above
cc: Mr. John S. Berggren,
Bounty Development Co.
825 "L' STREET
ANCHORAGE, ALASKA 99501
(907) 264-4111
June 17, 1980
Dave Griener
% Tryck, Nyman and Hayes
740 I Street
Anchorage, Alaska 99501
Subject: Southpark Subdivision
This department has reviewed the requested soils prior to
final approval and inspected the site on June 16, 1980.
The soils work is adequate and this department finds the
following criteria necessary for approval of Southpark
Subdivision:
(1)
Lot 4 Block 1; must be combined with Lot 3 Block 1
due to lot size, high water table, slope and limited
area due to 100 foot creek set ])ack.
(2)
Lot 1 Block 3; has ground water streams crossing or
existing from the lot with marshy areas noted. This
department requests the lot be incorporated with
another lot.
(3)
Re-design sewer system location on Lot 2 Block 3 due
to water seeps at ground level for proposed leach-
field area. Water seeps noted at base of the cutbank.
(4)
Lot 3 Block 3; proposed sewer leachfield area located
in fill consisting of root wads and organic material.
Sewer system must be relocated.
(5) Submit letter of intent guaranteeing proper abandonment
of dry wells.
Dave Griener
% Tryck, Nyman
June 17, 1980
Page Two
and Hayes
(6)
Submit ~lans and State approval
system and its adequacy. Also,
well and water system.
of tenative water
dispensation of
If there are any furLher questions, please call this
office at 264-4720.'
Sincerely,
John W. Lynn
Environmental Specialist
JWL/ljw
cc: Jerry Weaver
Planning Department
71.1
June 16, 1980
Municipality of Anchorage
Plan~ting Depar tmellt
City ilall Annex
Ancilorage, AK 99501
Attention: Hr. Jerry Weaver
Subject:
Southpark Subdivision
Water Supply -
Jerry:
As you know, we are in tile process gl~ completing the final plat for
the firs': phase of Sou~hpark Subdivision consisting of 23 'lots and 2
tracts. One of ~he conditions of approval is to provide a come,unity
water system.
Au adequate supply of water for the first phase can be served by
the existing well drilled last sumner, located directly east of the gas
line and north of Southpark Bluff Drive. This well has been pump tested
and found to have a sustained yield in tile range of lO gallons per
mi)lute. The system proposed for this first phase would connect the well
directly to the distribution system. Each residence would be required
Lo install its own pressure/storage tank (similar to a Well-X-Troll,
Model 252) which would allow water flow not only into the house, but
also back out to tile main distribution lithe.
After completion of the first phase, several options are available
for expanding the system, l'he first alternative is to utilize the well
drilled this spring located off-site in Little Rabbit Creek Valley, east
of the gas line. This well was pump tested with a sustained yield of 14
gallons ))er minute. When tied in with either individual pressure tanks
or a centralized storage tank, this well would be capable of serving all
of the 53 lots approved within Southpark Subdivision.
Another alternative for providing community water to the approved
subdivision (or additional surrounding properties) is installing an
infiltration gallery along the banks of Little Rabbit Creek. This
concept bas been reviewed by the Department of Environmental Conservation
-2-
Mr. Jerry Weaver
8171.1
June 16, 1980
and }{as received their concept approval. ^ copy of ti)etr letter is
attached.
The proposed infiltration gallery system would consist of approximately
100 feet of trench backfilled with layered sands and gravels. A perforated
pipe would be placed in the bottom of the trench (approximately 20 feet
deep) and would be designed to have backwash capability to allow cleaning
of tile filter material when required. This trench would collect,
filter, and direct the water to a screened well casing similar to that
of a typical well. From the well, the water would be pumped directly
through a filter which would consist of a fabric screen {Renntngen-
Petter type) which would have the capability of filtering out trace
contaminents. The water would then be chlorinated and pumped to the
distributio)) sysCem. This syst~ would have the capability of producing
approxi,,~ately 300 to 400 gallons per minute.
If you have any questions or desire additional information at this
time, please advise.
Very truly yours,
TRYCK, IiYMAN & HAYES
David A. Grenier, P.E.
cbh
A~tachmen~: As above
cc: Mr. John S. Berggren
FLEVATION:
FIELD LOG
CLIENT
DRILLING CONTRACTOR
RR~LLER
EQUIPMENT
SAM~ER
SOIL DESCRIPTION
W_O. RK~O. RDE R NO.
_TIM~ START
TIME FINISH
WATER LEVELj~*_,I, 'TIME --
SHEET OF
COMMENTS
FI EVATION:
FIELD LOG
CLIENT
DRILLING CONTRACTOR
SAMPLER
SOIL DESCRIPTION
BORING _N QL "~__~-~ ,-~'i
W~ORK ORDER N..O~
TIMF' W_ART
TIME FINISH
WATER LEVEL//lll ¢TIME
SHEET OF
COMMENTS
~ALAS K~'~-~T'E$~LA B
ELEVATION:
FIELD LOG
CLIENT
DRILLING CONTRACTOR_~' .~,)
_O_R!i:_LER
EQUIPMENT
SAMFA_ER
SOIL DESCRIPTION
W~ORK~OROER NO.
TIM~TART
TIME FINISH
WATER L EVE LJ~/~_~,/<. TIME
SHEET OF
COMMENTS
ELEVATION:
FIELD LOG
CLIENT
SOIL DESCRIPTION
BO_R. iN__G__Ng~__7 - / ....
WORK OHDER NO,
T~IM~_R T
TIME FINISH
W~ATER _Lg~.EL/~*,~_TJ_ME_
COMMENTS
,/,.,,/j
WELL RESERVE EASEMENT
AFFECTING PORTIONS OF TRACTS A; LOT 6, BLOCK 2; LOT 8, BLOCK 3 & LOT 9,
BLOCK 3
SOUTHPARK SUBDIVISION
An easement is hereby created for the purpose of restricting the use of
portions of Tract A; Lot 6, Block 2; Lot 8, Block 3 & Lot 9, Block 3 in
Southpark Subdivision, a Subdivision of Tract A, Road Dedication, (Plat
No. P77-21) to provide a well reserve within a 200.00 foot radius of a
proposed well. The restrictions placed on the use of the above-described
tract and lots are in accordance with Title 18 of the State of Alaska
Administrative Code, Environmental Conservation, Chapter 80, Drinking
Water, whereas the minimum separation between the well and wastewater
treatment and disposal systems, sewage pump stations, sewer main clean-
outs, sewer line manholes, coinmunity sewer lines, and other potential
sources of contaminants, all as defined in said Chapter 80, shall be
200.00 feet (unless a lesser distance is approved by the State), and the
minimum separation between the well and private sewer lines shall be
100.00 feet.
The limlts of the well reserve easement are shown by attached "Exhibit
A, Southpark Well Site" and the easement is described more particularly
as follows:
The area within a circle having a radius of 200.00 feet and a
center point located as follows: Beginning at the southeasterly
corner of Lot 6, Block 2, thence South 62° 20' 45" East 119.8 feet
more or less, thence North 27° 39' 15" East 34.6 feet more or less
to ~]e well casing.
IN WITNESS WHEREOF, the persons below as owners and/or representatives
of the af~ec~ted tracts~aDd lots hereunto set their hands and their seals
this ~r/~day of __(--~/~(/~%~_ , 1980.
/
GEneRAL ENTERPRISES ~ INC.
NOTARY ' S ACKNOWLEDGEMENT ' '
S%[bscribed and sworn to before me this __~_~/~/day o.f
, 198o, , ./:---
~ ~"or' Alaska
My commission expires ~.~/62~
rm
rn
R,::...! IVED
JUN 2 7 ]980
To,el<, Nyma;l & Ilayes
4040 "B" STREET
ANCHORAGE, ALASKA 99,503
(907) 278-1551
DATi:: I~ROJI=OT / W.O.
MEMO su.aECT:
SIGNED',
May 9, 1980
W.O. #A19218
Bounty Development Company
SRA Box 470-B
Anchorage, Alaska 99507
Attention: John Berggren
Subject: Phase I, Southpark Terrace Estates, Soils Investigation
Gentlemen:
We herewith transmit four copies of the subject report. The
purpose of this investigation was to determine the feasibility of
constructing on-site wastewater disposal systems. Design absorp-
tion areas for the drain fields are given on a lot-by-lot basis.
Sincerely yours,
ALASKA TESTLAB
James R. Finley, Jr.,
Geotechnical Engineer
PoE.
Approved by:
Melvin R. Nichols, P.E.
Laboratory Manager
JRF/mg
Attachments
cc: Dave Grenier,
Tryck, Nyman & Hayes
TABLE OF CONTENTS
Introduction .
General Conclusions
Soils and Surficial Geology
Ground Water
Percolation Rates
Field Exploration Program and Percolation Test Methods
Pag_~
1
2
3
6
6
'7
Table A - Percolation Test Results
Table B - Recommended Absorption Areas
Tables C-O - Test Hole Logs
Sheets 1-7 - Grain Size Distribution Curves
Sheets 8-10 - Standard Explanatory Information
Appendix A - Soils and Recommended Septic System Design Criteria
for Individual Lots
Appendix B - Report Dated January 26, 1979, Titled "Addendum
No. 1 to Subsurface Investigation, 40 Acre Parcel
on Old Seward Highway" and Report Dated January 23,
1979, Titled "Subsurface Investigation, 40-Acre Parcel
on Old Seward Highway"
SOILS INVESTIGATION
SOUTHPARK TERRACE ESTATES SUBDIVISION, PHASE I
ANCHORAGE, ALASKA
Prepared for
BOUNTY DEVELOPMENT COMPANY
Prepared bY
ALASKA TESTLAB
SOILS INVESTIGATION
SOUTHPARK TERRACE ESTATES SUBDIVISION,
ANCHORAGE, ALASKA
PHASE I
INTRODUCTION
This report presents the results of a subsurface investigation
and sununarizes the results from two previous investigations
conducted in the western one-half proposed Southpark Terrace
Estates Subdivision. Southpark Terrace Estates is located south
of Anchorage off the Old Seward Highway, south of Little Rabbit
Creek and east of Potter Marsh. The 40 acre parcel is in Section
SW 1/4 of the NE 1/4, Township 11, Range 3W, Seward Meridian,
Alaska.
In October 1978, Mr. John Berggren excavated 19 test pits on the
property. The purpose of these test pits was to determine soil
conditions to evaluate the feasibility of using the property as a
gravel pit and aggregate source. In January 1979, Alaska Testlab
was retained to determine the suitability of the parcel for a
proposed subdivision having on-site wastewater treatment systems.
Visual classifications of the 19 test pits dug with the client,
Mr. John Berggren, was verified by Mr. James Mack from Alaska
Testlab. Verification involved cleaning out the snow and the
sluffed soils in the test pits. Then Test Holes 20 through 34
were excavated with a backhoe and logged by Alask~ Testlab.
During this same program, Test Holes 35 through 37 were drilled
using a Nodwell mounted Mobile B-50 drill rig equipped with a
solid flight auger. Percolation tests were performed in these
test borings.
A report was issued on January 23, 1979 which included the results
of the test borings and test pit excavations (Holes 1 through
37). Addendum No. 1, issued on January 26, 1979, contained a map
of soils in the proposed subdivision showing estimated percola-
tion rates. Further information was required and on September 12,
1979, Alaska Testlab, at the request of the client, attempted to
perform percolation tests in Test Pits 2, 6, 7, 10, 14, 15 and
22° These test pits were flooded with water using a water truck.
It was planned to conduct the percolation'test the following day.
Up to 100 gallons of water was placed in each of the test pits
and it was estimated that the percolation rates of the soils was
between one and five per inch in every hole. It was concluded
that the map in Addendum No. 1 showing estimated percolation
rates were representative of values for percolation properties in
the test pit areas.
The current investigation involved drilling 13 test borings at
selected areas within the proposed subdivision for the purpose of
performing percolation tests and evaluating the required septic
system absorption trench area for each lot.
For convenience, each lot is discussed individually in the
appendix. A general description of the soils conditions, ground
water conditions is presented along with a recommended location
for the septic system. A percolation rate is given based on
either borings and percolation tests on the lot, or from adjacent
lots within the same landform. The following is a generalized
discussion and summary of the study.
GENERAL CONCLUSIONS
Most of the Phase I area of the proposed subdivision is suitable
for the construction of on-site wastewater disposal systems.
Soils are, for the most part, coarse and free-draining. Percola-
tion rates measured by field tests range from 0.5 to 8 minutes
per inch.
At this time the northern part of~the proposed subdivision is
unsuitable for placement of conventional on-site sewage disposal
2
system due to a high ground water table. This includes Lots 7
and 8 of Block 1 and Lots 1, 2 and 3 of Block 2. However, with
development of the surface drainage system and the public water
system this condition may well be alleviated. Less significant
amounts of ground water were detected in Block 1, Lots 1 through
4 where seepage was observed in two test holes after drilling.
The amount of down slope seepage in this area is probably small
and the condition temporary. Drain fields mos~ probably can be
placed on the down slope portion of these lots because the soils
are granular in that area. Because of the free-draining charac-
teristics, no shallow down slope seepage is expected in this
area. Lots 4, 5 and 6 of Block 2 could have ground water, but a
drain field system which meets state and municipal regulations
can probably be constructed on these lots by using a shallow
absorption trench.
Table A lists the results of the percolation tests and Table B
the recommended design drain field absorption rates per lot. If
actual soil conditions vary from the assumed conditions as stated
in the discussion in Appendix A, the absorption area requirements
may change. A more free-draining soil may result in less absorp-
tion area required. A tighter, siltier soil may result in the
need for more absorption area. We cannot over emphasize the need
for careful lnspectlo of each system as it is constructed.
SOILS AND SURFICIAL GEOLOGY
The surficial geology of the region has been mapped by the U.S.
Geologic Survey(1) on a s~cale of 1 to 24,000. Because of the
large scale of the geologic map, a study of the available aerial
'(1)
Schmoll, H. R. and Dobrovolny, E., 1972, Generalized Geologic
Map of Anchorage and vicinity, Alaska, U.S. Geologic Survey.
3
photography and test boring information was initiated to refine
the map in the area of concern. Figure 1 shows a generalized
surficial geology map of the proposed.subdivision. The U.SiG.S.
identified three landforms within the 40 acre parcel including:
al -
gm -
alluvium in abandoned stream channels and terraces along
modern streams; gravel and sand generally well bedded and
well sorted. Generally excellent material for on-site
sewage disposal.
glacial and marine deposits consisting chiefly of dimicton,
but including some beds of fine sand and silt. Thin beds of
gravel and sand occur locally. These soils are generally
adequate for on-site sewage disposal.
mg -
marine, glacial and lacustrine deposits consisting of a
variety of interbedded materials with some fine-grained
material including dimicton, stoney silt, silt, fine-grained
sand and some clay. These soils must be examined closely as
to their suitability for on-site sewage disposal.
Dimicton is a glacial till consisting of a mixture of silt, sand
and gravel. Often it contains scattered cobbles and boulders.
Through the center of the property and along the western boundaries
in Lots 1, 2, 3, and 4, Block 1, there is a deposit of granular
soil which appears to be kame terrace deposits. A kame terrace
is an accumulation of stratified drift or a~lluvium layed down by
streams between the margin of the glacier and the adjacent valley
wall. Upon disappearance of the glacier, the deposit is left as
a constructional terrace which differs from a stream terrace in
that it does not represent the remnants of a mass of sediment
found extending completely across the valley. Kame terraces are
usually flat and narrow and is often pitted by kettles. In some
areas, as in this subdivision, several terraces occur in a series
4
marking successive positions of ice-marginal streams as a glacier
thinned by wasting.
Soils in this landform are characterized by Test Pits 19, 22, 28,
32, 15, and 8, also Boring 5-2. Soils are' generally non-frost
susceptible and contain only a trace of silt are generally well
sorted and well graded. The grain size distribution of typical
composite soil samples, Groups B and C, are shown on Sheets 1
through 4.
The hill on Lots 5 and 6, Block 1 was mapped as "gm" by the
U.S.G.S. Test Pit 23 appears to confirm this, as 12 feet of
gravelly silt was found. However, Test Pits 23A and Boring 35
found clean layered sands and gravels. It is probable that this
is a glacial alluvium overlying glacial till. Glacial alluvium
is defined as material deposited in irregular shaped hills in or
near glacial ice consisting chiefly of gravel and sand, moderately
well bedded and well sorted.
The other hills and slopes are glacial till deposits, either the
"mg" or the "gm" landform units. These two units often grade
from one to the other and the chief difference is that the "mg"
landform is often interbedded with sands and gravels and the "gm"
landform is predominantly dimicton, or a mixture of gravel, silt
and sand. Soils in these landforms can vary significantly over
very short distances. Groups D and E are typical soils in this
landform although layers of Group B and C soils can be found.
Sheets 5 through 7 show the grain size distribution for these
soils. Borings 36, 8-3, 9--3 and 7-3 show typical soil strati-
graphy in this landform unit.
Lots 1, 2 and 3 in Block 3 and Lot 4 in Block 4 contain some
areas of clean fine to medium sand. The limits of these deposits
are not well defined by the present available information.
5
GROUND WATER
Several areas of high ground water were observed. On Lot 3'of
Block 2, five test borings were drilled and high ground water was
encountered in all five while drilling. ~our of the borings
(Boring I-2, 8-1, 4-1 and 1-1) on the lower or west side of the
property were dry when drilling, however, when a percolation test
was attempted several days later, the holes were filled with
water (1-1/2 to six feet below the surface). Test Pit 23 also
encountered water seepage from three to four feet and Test Pit 23A,
at eight feet depth. The water present is the result of downstope
seepage.
Test Pits 19 and 22 encountered clean gravels with no water.
However, Test Borings 1-1 and 4-1 were drilled upslope. These
test pits were located on the lower part of the slope on a gravel
terrace. Lots 4 and 5 may also have water problems. Boring 5-2
encountered ground water at 13 feet while drilling and Boring
3-2A, drilled on the boundary between Lots 3 and 4, encountered
water at seven feet.
PERCOLATION RATES
Percolation rates are quite high in the alluvial deposits because
of the high permeability of the soils. Permeability is a physical
property of the soil and is a measure of the ease of which water
flows through the material. It depends predominantly on the soil
grain size. Percolation rates in the granular, clean soils are
less than two minutes per inch. Based on design criterJ, a in the
"Manual of Septic Tank Practice", published by the U.S. Department
of Health, Education and Welfare, Public Health Service, the
required absorption area in square feet per bedroom is 85 square
feet. It is recommended that the septic systems be designed to
provide a minimum absorption area of 100 square feet because the
permeability of the soil. can decrease with continued use of the
6
drain field system. The glacial alluvial deposits in Lots 5 and
6 of Blocks 1 also have similar permeability and absorption area
requirements.
The soil in the glacial till
lot. The maximum percolation
(gm or mg) deposits vary from lot to
rate measured was 0.5 minutes per
inch. The boring in which this test was conducted had a thick
clean sand layer. The minimum percolation rate was eight minutes
per inch in Boring 8-3 and in Boring 36. The absorption area
requirements will depend on exactly where the drain field system
is placed on the lot and the soils encountered in the drain field
trench. Where no percolation test was performed on the lot, the
assumed percolation rate in this landform was eight minutes per
inch, thus the required absorption area is 150 square feet per
bedroom. Table A lists the results of the percolation tests and
Table B the recommended design absorption rate for each lot.
FIELD EXPLORATION PROGR~34 AND PERCOLATION TEST METHODS
The current exploratory program was conducted on April 10 and tl,
1980 and the percolation tests on April 14 and 15, 1980. The
test borings were drilled to a depth of 16 feet by a Mobile B-50
drill rig mounted on a Nodwetl carrier and equipped with solid
'flight augers. The drill is owned and operated by Denali Drilling,
Inc. The operation was supervised, the test holes were logged,
and the percolation tests performed by Mr. O.Mo Hatch, Alaska
Testlab engineering geologist. Samples were collected by retrieving
them as they were brought to the surface b~ the augers. The
samples were classified and placed in plastic bags to preserve
the natural moisture content. In the laboratory the samples were
again visually classified and the moisture content of each sample
was measured. The moisture contents appear on the boring logs,
Tables C through O.
7
A slotted PVC pipe was placed in the hole after drilling to keep
the test hole open. The pipe in the hole was then filled with
water and left to soak overnight.
the holes were refilled with water
observed for a period of one hour.
period of 10 minutes was recorded.
Upon returning the next day,
and the percolation rate
The lowest percolation for a
This is not a standard
percolation test, but we understand that the Municipality prefers
that the test be conducted in this manner.
8
TABLE ~A
PERCOLATION TEST RESULTS
~orin~
1979 Series
35
36
37*
1980 Series
5-2 (Lot 5,
3-3
4-3
5-3
7-3
8-3
9-3
4-4
Block 2)
Percolation Rate
(Minutes/Inch)
3
8
27
1
0.5
0.5
8
0.5
8
1.6
2
Landform
mg/gm
mg
al
al
mg/gm
mg/gm
mg/gm
mg/gm
mg/gm
al
*Not in Phase I area
TABLE B
RECOMMENDED ABSORPTION AREAS
Block
1
2
2
2
2
3
3
3
3
3
3
'3
3
4
4
4
4
Lot
1
3
5
6
7'
2~
3'
4
2
3
4
5
6
7
8
9
2
3
4
Absorption Area
(ft /bedroom)
Comments
100
100
150
150
Upper part of lot is silt with
high water level. DO not install
system in this area.
Upper part of lot is silt with
high water level. Do not install
system in this area.
Possible high water level due to
downslope seepage.
Possible high water level due to
downslope seepage.
100
100
Possible high ground water.
tlon necessary.
High ground water.
Further explora-
High ground water.
High ground water.
High ground water.
100 Possible seepage (7' to 13'
depth) on northeast portion of
lot.
100 Water at 13' depth in April 1980.
lO0
100
100
150
150
150
150
150
125
Soils conditions may be highly
variable.
150
150
150
100
Test ttole #Lot 1,
Block 1
Table C
WO #A19218
Date: 4/10/80
Logged by: O.
Hatch
D__epth in Feet
From To
0.0 1.0
1.0 2.0
2.0 6.0
6.0 8.0
8.0 16.0
Soil Description
Brown Peat, soft, Pt
F-4, brown Sandy. Silt, damp, medium dense,
non-plastic, ML
NFS, brown Sandy Gravel, 45% sand, damp,
medium dense, rounded particles to 3", GW
F-l, brown Silty Sandy Gravel, damp, medium
dense, subrounded particles to 6", GM
F-4, brown Gravelly Sandy Silt, very gravelly
13' to 16', damp, stiff, non-plastic, ML
Bottom of Test Hole:
Frost Lille:
Free Water Level:
16.0 Feet
1.0 Foot
None Observed While Drilling
5.0 Feet After Drilling (4/14/80)
Sa.
No. Depth
1 5.0
2 10.0
3 15.0
Type of Dry
Blows/6" M% Sample S_trength Group Unified
4.7 G N C GW
8.7 G N D ML
8.9 G N D ML
Remarks: 1.
30
50
60
Type of Sample, G=Grab, SPT = Standard Penetration,
U = Undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
Test Hole #Lot 4,
Block 1
Table D
WO #A19218
Date: 4/11/80
Logged by: O.
Hatch
Depth in Feet
From To
0.0 1.0
1.0 3.0
3.0 10.0
10.0 16.0
Soil Description
Brown Peat, damp, soft, Pt
F-4, brown Sandy Silt, damp, medium dense,
non-plastic, ML
F-4, brown Gravelly Sandy. Silt, 20% gravel,
damp, dense, non-plastic, subrounded particles
to 6", ML
F-l, brown very Silty Sandy
30% sand, 40% gravel, damp,
to 6", SM/GM
Gravel, 30% silt,
subrounded particles
Bottom of Test Hole:
Frost Line:
Free Water Level:
16.0 Feet
1.0 Foot
None Observed While Drilling
6.0 Feet After Drilling (4/14/80)
Sa.
No. Depth
1 5.0
2 10.0
3 15.0
Type of Dry
Blows/6" M% Sample Strength Group Unified
7.9 G N D ML
8.9 G N D ML
7.9 G N D SM
Remarks: 1.
3.
4.
5.
6.
Type of Sample, G=Grab, SPT = Standard Penetration,
U = Undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, .see Sheet 3.
Test Hole #Lot 8,
Block 1
Table E
WO #A19218
Date: 4/11/80
Logged by: O. Hatch
D__epth in Feet
From To
0.0 0.5
0.5 3.0
3.0 12.0
Soil Description
Brown Peat, damp, soft, Pt
F-4, brown Gravelly Sand~ Silt, damp, dense,
non-plastic, ML
F-4, brown to olive Gravelly Sandy Silt,
fine to coarse sand, 15 to 25% gravel, 40 to
50% sand, damp, medium dense, subrounded
particles to 3", grades siltier at 12' depth,
ML
Bottom of Test Hole:
Frost Line:
Free Water Level:
12.0 Feet
1.0 Foot
None Observed While Drilling
2.5 Feet After Drilling (4/14/80)
Sa.
No. Depth
1 5.0
2 10.0
3 15.0
Type of Dry
Blows/6" M% Sample Strength ~roup Unified
7.7 G N D ML
9.4 G N D ML
10.6 G VL D ML
Remarks: 1.
3.
4.
5.
6.
Type of Sample, G=Grab, SPT = Standard Penetration, .
U = Undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
Test Hole
#Lot 1,
Block 2
Table F
WO #A19218
Date: 4/11/80
Logged by: O.
Hatch
Depth in Feet
From To
0.0 0.5
0.5 7.0
7.0 16.0
Soil Description
Brown Peat, damp, soft, Pt
F-4, brown to olive Gravell_~ Sandy Silt,
damp, ML
F-2/F-4, olive Gravelly. Silty Sand, fine to
coarse sand, damp, medium dense, grades to
gravelly sandy silt by 15' depth, SM/ML
Bottom of Test Hole:
Frost Line:
Free Water Level:
16.0 Feet
1.0 Foot
None Observed While Drilling
1.5 Feet After Drilling (4/14/80)
Sa.
No. Depth
1 5.0
2 10.0
3 15.0
Type of Dry
~lows/6" M% Sample Strength ~roup Unified
13.6 G VL D ML
9.0 G N E SM.
12.2 G VL D ML
Remarks: 1.
3.
4.
5.
6.
Type of Sample, G=Grab, SPT = Standard Penetration,
U = Undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
Test Hole #Lot 3,
Block 2
Table G
WO #A19218
Date: 4/11/80
Logged by: O.
Hatch
D__epth in Feet
From To
0.0 1.0
1.0 2.0
2.0 8.0
Soil Description
Brown Peat, damp, soft, Pt
F-4, brown Sandy Silt, damp, stiff, non-plastic,
ML
F-4, brown very Gravell~ very Sandy Silt,
damp to saturated, dense, non-plastic, ML
Bottom of Test Hole:
Frost Line:
Free Water Level:
8.0 Feet
1.0 Foot
Boring 3-2 2.0 Feet:
Boring 3-2A -'7.0 Feet
Boring 3-2B - 6.0 Feet
Boring 3-2C - 6.0 Feet
. Boring 3-2D - 4.0 Feet
Sa.
Depth
5.0
Type of Dry
Blows/6" M% Sample Strength Group Unified
9.1 .G N D ML
Remarks: 1.
3.
4.
5.
6.
Type of Sample, G=Grab, SPT = Standard Penetration,
U = Undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
Test Hole #Lot 5,
Block
Table H
WO ~A19218
Date: 4/11/80
Logged by: O.
Hatch
D__epth in Feet
From To
0.0 0.5
0.5 1.5
1.5 14.0
14.0 16.0
Soil Description
Brown Peat, damp, soft, Pt
F-4, brown Sandy Silt, damp, dense, non-plastic,
NFS, brown very Sand~ Gravel, trace silt,
40 to 5C% sand, damp, medium dense, rounded
particles to 3", saturated at ~3' depth, GM/GW
F-4, brown Sandy Silt with trace gravel,
saturated, non-plastic, ML
Bottom of Test Hole:
Frost Line:
Free Water Level:
Percolation Rate =
16.0 Feet
1.0 Foot
13.0 Feet While Drilling
1 minute/inch with water level at 5.0 feet
PVC pipe
in
Sa.
No. Depth
1 5.0
2 10.0
3 15.0
Type of Dry
~lows/6" M% Sample ~trength ~roup Unified
13.7 G N C GM/GW
6.3 G N C GW
12.1 G L D ML
Remarks: 1.
3.
4.
5.
6.
Type of Sample, G=Grab, SPT = Standard Penetration,
U = Undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
Test Hole ~Lot 3, Table I
Block 3
WO ~A19218
Date: 4/10/80
Logged by: O. Hatch
Depth in Feet
From To
Soil Description
0.0 1.5 F-4, brown Sandy Silt, damp, dense, non--
plastic, ML
1.5 8.0 NFS, brown Gravelly Sand, fine to coarse,
20% gravel, damp, medium dense, rounded to
subrounded particles to 1", SP/SW
8.0 10.0
F-l, brown Silty Gravelly Sand/Sandy Gravel,
damp, medium dense, rounded to subrounded
particles to 2", GW-GM/GM
10.0 16.0 NFS, brown Sand with traces of gravel and
silt, fine to coarse, damp, medium dense, SP/SM
Bottom of Test Hole:
Frost Line:
Free Water Level:
Percolation Rate = 0.5 minutes/inch with water level
falling 11.5 feet in 70 minutes
16.0 Feet
0.5 Feet
None Observed While Drilling
in PVC pipe
Sa. Type of Dry
No. Depth Blows/6" M% Sample Strength Group Unified
1 5.0 5.1 G N B SW
2 10.0 6.5 G N C GM/GW
3 15.0 7.1 G N B SM/SP
Remarks: 1.
3.
4.
5.
6.
Type of Sample, G=Grab, SPT = Standard Penetration,
U = Undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
Test Hole ~Lot 4,
Block 3
Table J
WO ~A19218
Date: 4/10/80
Logged by: O.
Hatch
Depth in Feet
From To
0.0 0.5
0.5 1 .5
1.5 3.5
3.5 12.0
12.0 16.0
Soil Description
Brown Subsurface Organics, soft, Pt
F-4, brown Sa~_~y Silt, damp, dense, non-
plastic, ML
F-4, brown Gravelly Sandy ~ilt, damp, dense,
non,plastic, subrounded particles to 2"
F-2, brown silt~ fine Sand with traces gravel,
40 to 45% nbn-plastic silt, damp, medium dense,
grades to 30% silt by 10'
F-4, brown Gravelly Sand~ ~ilt, 20% gravel,
damp, medium dense, non-plastic, ML
Bottom of Test Hole:
Frost Line:
Free Water Level:
Percolation Rate = 0.5 minutes/inch with water level
falling 7 feet in 45 minutes
16.0 Feet
1.0 Foot
None Observed While Drilling
in PVC pipe
· Sa. Type of Dry
No. Depth Blows/6" M% Sample Strengt~ ~roup Unified
1 5.0 14.1 G VL -- ML
2 10.0 9.8 G N -- SM
3 15.0 11.4 G VL D ML
Rsmarks: 1.
3.
4.
5.
6.
Type of Sample, G=Grab, SPT = Standard Penetration,
U = Undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
Test Hole
#Lot 5,
Block 3
Table
WO #A19218
Date: 4/10/80
Logged by: O. Hatch
~pth in Feet
From To
0.0 1.0
1.0 16.0
Soil Description
F-4, brown Sandy Silt with trace Peat, damp,
medium dense, non-plastic, ML
F-4, brown Gravelly Sandy Silt with some
cobbles and boulders, damp, stiff, non-plastic,
subrounded particles to 8", ML
Bottom of Test Hole:
Frost Line:
Free Water Level:
16.0 Feet
Trace Observed
None Observed While Drilling
Percolation Rate = 8 minutes/inch with water level at 4.0 feet depth
in PVC pipe
Sa. Type of Dry
No. Depth ~$1ows/6" M% S_ample Strength Group Unified
1 5.0 11.4 G VL/N D ML
2 10.0 8.2 G VL/N D ML
3 15.0 10.2 G VL D ML
Remarks: 1.
3.
4.
5.
6.
Type of Sample, G=Grab, SPT = Standard Penetration,
U = Undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
Test Hole #Lot '7,
Block 3
Table
L
WO #A19218
Date: 4/11/80
Logged by: O. Hatch
De~)th in Feet
From To
0.0 0.5
0.5 1.5
1.5 10.0
10.0 16.0
Soil Description
Brown Feat, damp, soft, Pt
F--4, brown Sandy Silt, damp, medium dense,
non-plastic, ML
F-l, brown very Silty Sandy Gravel/Gravell~
Sand, damp, dense, SM/ML
F-4, brown Gravelly ~and~ Silt, damp, very
dense, 10 to 20% gravel, non-plastic, ML
Bottom of Test Hole:
Frost Line:
Free Water Level:
Percolation Rate =
16.0 Feet
1.0 Foot
None Observed While Drilling
0.5 minutes/inch with water level in PVC pipe
falling 9.0 feet in 50 minutes
No. Depth
5.0
10.0
15.0
Type of Dry
Blows/6" M% Sample Strength Group Unified
9.7 G N D ML/SM
10.9 G N D SM
10.7 G N D ML
Remarks:
3.
4.
5.
6.
Type of Sample, G=Grab, SPT = Standard Penetration,
U
TM undisturbed.
Dry Strength, N=None, L=Low,.M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural ClassJ. fication, see Sheet 2.
Unified Classification, see Sheet 3.
Test Hole
#Lot 8
Block 3
Table M
WO #A19218
Date: 4/11/80
Logged by: O.
Hatch
Depth in Feet
From To
0.0 0.5
0.5 2.5
2.5 4.0
4.0 7.0
7.0 9.0
9.0 16.0
Soil Description
Brown Feat, damp, soft, Pt
F-4, brown Gravelly Sandy Silt, damp, dense,
non-plastic, subrounded particles to 2", ML
F-l, brown Silty Sandy Gravel, damp, dense,
rounded and subrounded particles to 3", GM
NFS, brown Sandy Gravel with trace silt and
cobbles, damp, dense, rounded and subrounded
particles to 6", GW/GM
NFS, brown Gravelly Sand, fine to coarse sand,
damp, dense, rounded particles to 1"
F-4, brown Sandy Gravell~ Silt, 30 to 40%
coarse sand, damp, medium dense, ML
Bottom of Test Hole:
Frost Line:
Free Water Level:
Percolation Rate =
16.0 Feet
1.0 Foot
None Observed While Drilling
8 minutes/inch with water level at
PVC pipe
6.0 feet in
Sa.
No. Depth
1 5.0
2 10.0
3 15.0
Type of Dry
Blows/6" M% Sample Strength Group Unified
7.3 G N C GW/GM
9.3 G VL D ML
10.5 G VL D ML
Remarks: 1.
3.
4.
5.
6.
Type of Sample, G=Grab, SPT = Standard Penetration,
U = Undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
Test Hole #Lot 9,
Block
Tab].e N
WO #A19218
Date: 4/11/80
Logged by: O. Hatch
Depth in Feet
From To
0.0 0.5
0.5 1.5
1.5 6.0
6.0 8.0
8.0 13.0
13.0 16.0
Soil Description
Brown Peat, damp, soft, Pt
F-4, brown Sandy Silt, damp, medium dense,
non-plastic, ML
NFS, brown fine to coarse Sand with traces
of gravel and silt, damp, medium dense, SP/SM
F-2, brown fine to coarse Silty Sand with -traces
of gravel, damp to wet, medium dense, SM
~'-2, brown slightly Silty Gravelly Sand, damp,
medium dense, SW/SM
F-4, brown Gravelly Sandy Si~t, damp, medium
dense, non-plastic, rounded and subrounded
particles to 2", ML
Bottom of Test Hole:
Frost Line:
Free Water Level:
Percolation Rate = 1.6 minutes/inch with water level
in PVC pipe
16.0 Feet
1.0 Foot
None Observed While Drilling
at
6.0 feet
Sa. Type of Dry
No. Depth Blows/6" M% Sample Strength Group Unified
1 5.0 8.6 G N B SP/SM
'2 10.0 5.7 G N C SW/SM
3 15.0 11.3 G VL D ML
Remarks: 1.
3.
4.
5.
6.
Type of Sample, G=Grab, SPT = Standard Penetration,
U = Undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
Test Hole #Lot 4,
Block
Table 0
WO #A19218
Date: 4/10/80
Logged by: O. Hatch
D_~e~h in Feet
From To
0.0 0.5
0.5 1 .5
1 .5 8.0
8.0 16.0
Soil Description
Brown Peat, damp, soft, Pt
F-4, brown Sandy Silt, damp, medium dense,
non-plastic, ML
F-4, brown Gravelly Sandy Silk, damp, medium
dense, non-plastic, ML
NFS, brown fine to medium Sand with traces of
silt and gravel, damp, medium dense, rounded
particles to 2", grades coarser at 15', SP/SM
Bottom of Test Hole:
Frost Line:
Free Water Level:
Percolation Rate = 2
16.0 Feet
1.0 Foot
None Observed While Drilling
minutes/inch with water level at
PVC pipe
6.5 feet in
1
2
3
Depth
5.0
10.0
15.0
Type of Dry
Blows/6" M% Sample Strength Group Unified
11.5 G N -- ML
8.9 G N B SP/SM
3.4 G N B SW
Remarks:
3.
4.
5.
6.
Type of Sample, G=Grab, SPT = Standard Penetration,
U = Undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
g
.J
g
o o ~ ,~ o 3 o o o o o
Test Hole Log - Description Guide
precision of a laboratory testing procedure. If thc log includes soils samples,
to verify the field examination.
The logs often iuclude the following items:
Depth Intcrva~l - usually shown to 0.1 foot, within that zone no
significant change itl soil type wits observed through drill action, direct
observation or sampling.
Frost Classification - NFS, Fl, F2. F3, F4, see "Soil Classification
Chart"
Texture of Soil - An engineering classification of the soils by particle
size and proportion, see "Soil Classification Chart". hole tile
proportions are approximate and modifications to the soil group due to
stratification, inclusions aud changes in properties are included.
Moisture Content this is a qualitative measure:
~, no or little apparent surface moisture,
wet, ilo free water, often soft, if cohesive soil,
saturated, free water nla¥ b.e sqtleezcd out, ifa free drainiug soil:
sand. ('['he moisture content is further defincdby reference to
LW, NP, M%or dilatency.)
mixtures with or without a fine fraction, derived from drilbng action
and/or sample data; usually described as: very loose, loose, medium
Stiffness - refers to nlore-ordess cohesive soils and fine grained silts of
the clay-silt groups. Derived from drill action and/or sample data. Very
soft, soft, stiff, very stiff and hard are conlntonly used ternls.
Particle size - The largest particle recovered by tile split spuott is
1-3/8", Shelhy tube Y', auger flights (minute man)_'~", Auger flights
(B-SO hollow stem) 6"-8". Larger particles are descrihed indirectly by
action of tile drilbng and are referred to as cobbles, y' to 8", or
boullcrs 8 4. Therefore witch reviewing the gradation sheets, il' any,
tile description oil tile bole log must be considered for an bldication of
larger particles,
Unified Soil Cbssi£ication - This is a two letter code. See Unified
Classificatkm sheet for further definition, hi some cases AASHO and/or
FAA soil classifications may be shown ;ts well as the uniticd.
Atterberg Limits - useful for fine grained and other plastic soils.
P_l; natural moisture content believed to be less than plastic limit
PI+; natural moisture content believed to be between plastic and liquid
L~v+; natur,d nloisture content believed to be greater than liquid bnlit
NI~; nLm-plastic, useful as a modifying description uf some silty
Rock flour finely ground soil that is not plastic but otherwise appears
similar to ~ clayey silt.
Organic Content -- usually described as Peat, PT, sonlctimesincludes
~iscrcte particles such as wood, co;ti, etc. as a nlodifier to all inorganic
soil, Quantity described as; trace, or an estimate of volunle, or, itl case
of all organic, - as Peat. Tbis may include tundra, muskeg and bog
material.
Muck - a modifier used to describe very soft, semi-organic deposits
u~, ~ly occuring below a peat deposit.
Amorphus peat - organic particles nearly or fully disintegrated.
Fibrous Peat organic particles more-or-less intact,
Frost Linc - seasonal frost depth as described by drilling action and/or
samples at tbe time of drilling.
Frozen Ground -- other than frost line, described by samples, usually
includes description of ice content, often will include modified Unified
Classification for frozen soils - this is it special case re[sled to
permafrost studies.
Free Water Level - The frcc water level noted during drilling. This is
Blow/6" The number of blows of a 1,lO weight free fitlliug 30" to
advance a 2" split spoon 6"; the number of blows for a 12" advance is,
by definition, the staudard penetration.
natural Jnoisture content of the soil sample, usually not
pcrfornled on clean sands or grawqs below tile water table.
Type of Sample -
S~P, refers to 2" split spoon driven into tile soil by 140 pound
weight, a disturbed saulple,
S, thin wall tube, "Shelby" used to obtain undisturbed samples
of fine grained soil,
.G, "gr,,h' disturbed sample from auger flights or wall of t~ench,
SOIL CLASSIFICATION CHART
30% GRAVEL
CLAY
CLAYEY
CLAYEY CLAYEY
CLAYEY
DR
SILTY SILTY
SILTY ~
SAND
GRAVELLY SAND
SANDY GRAVEL
SILTY
GRAVEL
SAND GRAVELLY SAND SANDY GRAVEL GRAVEL -\
0 I 0 20 30 40 50 60 70 80 90 100
GRAVEL (+#4 SCREEN) % BY WEIGHT
NONFROST SUSCEPTIBLE SOILS ARE INORGANIC SOILS CONTAINING LESS THAN 3% FINER THAN 0.02 mm.
GROUPS OF FROST-SUSCEPTIBLE SOILS:
F1 GRAVELLY SOILS CONTAINING BETWEEN 3 AND 20% FINER THAN 0,02 mm,
F2 SANDY SOILS CONTAINING BETWEEN 3 AND 15% FINER TITAN 0.02 mm.
F3 a. GRAVE~LLY SOILS CONTAINING MORE THAN 20% FINER THAN 0.02 mm. AND SANDY SOILS
(EXCEPT FINE SILTY, SANDS) CONTAINING MORE THAN 15% FINER THAN 0.02 mm,
b. CLAYS WITH PLASTICITY INDEXES DP MORE TFIAN 12, EXCEPT VARVED CLAYS,
F4 a. ALL SILTS INCLUDING SANDY SILTS,
b, FINE SILTY SANI}S CONTAINING MORE THAN 15% FINER THAN 0.02 mm.
c, LEAN CLAYS WITH PLASTICITY INDEXES OF LESS THAN 12,
d, VARVED CLAYS.
TF1YCK" Office
NYMAN
ENGINEERS / PLANNERS/SURVEYORS
8]7] .o
February 13, 1979
Street Anchorage, Alaska 99501 /907 279-05
Cable TNHANCAK/Telex 090-25332
Department of Health & Environmental
Municipality of Anchorage
825 L Street
Anchorage, Alaska 99501
Protection
Attention: Mr. John W. Lynn
Subject:
Dear John:
Additional Information Regarding /~- ~"~
:Bou~ty:T, er~ace'Subdivision:, Case N°.(50777 "~l
Attached please find a preliminary plat of Bounty Terrace which
shows topographic information along with proposed well site locations.
Also attached is a copy of the sub-surface soil investigation reports
dated January 23, 1979 and Addendum No. 1 dated January 26.
A community well is proposed for this site along with on-site
individual sewer systems. The actual location of the well will depend
upon where a successful drilling attempt ]s made. When the well drilling
is completed, its location will be verified ]n the field by survey methods
and shown on the plat. The lot configuration will then be finalized so
that building sites and septic systems will be outside the required 200'
radius. In laying out the final plat design all applicable guidelines
of the Municipal Health and Environmental Protection Agency regarding
on-site septic systems and their relation to lot size and soil type will
be followed. We will resubmit the plat to your department which will
shown the actual location of the well and final lot layout for your approval.
If you have any questions or desire additional information at this
time please contact this office.
Very truly yours,
TRYCF,/~YMAN ~'/~IAYES/~
]ja
encl.
cc: John Berggren
JAY $. HAMI~OIVD, GOVEIrIIiOIt
338DENALISREET
MACKAYBUILDING, ROOM 1206
ANCHORAG~ ALASKA 99501
May 2, 1979
MUNICIPALITY OF ANCHORAGE
DEPT. Of ? "1.!:~ &
HHVIRONk'ENI'AL i ~ )iiC'I'ION
Mr. David A. Grenier
Tryck, Nyman & Hayes
740 I St.
Anchorage, Alaska 99501
RECEIVED
Dear Mr. Grenter:
We have received and reviewed a plat showing two
proposed locations for exploratory wells in the
subject subdivision. If sufficient water is lo-
cated, then a community system will be designed
and developed. Either location is acceptable to
this Department, and a certificate approving con-
struction of the exploratory well or wells is en-
closed with this letter. The construction approv-
al will be expanded to include the wellhouse,
distribution systems, and related facilities once
those plans are reviewed and approved by this
office.
If you have any questions pertaining to our review
of this proposal, please feel free to contact me
at 274-5527.
Sincerely,
James O. Starr
Environmental Engineer
Enclosure
cc:JDHEP
mm
18-06LH
LOT l, BLOCK 3
Soils and Ground Water
No test borings or test pits were drilled on this lot. Based on
the Generalized Geologic Map of Anchorage, the predominant land-
form on this lot is "mg" (glacial till). The soil conditions
appear to be quite complex. Areas of gravel and sand[ may well be
present.
Location of Septic System
The preferred location for the septic system drain field is on
the west, downslope side of the lot near the south property line.
D__e.~ign Absorption Area
As soils conditions are complex, it would be prudent to design
the septic system so as to provide an absorption area of 150
square feet per bedroom. This is the maximum required area for
other lots in Blocks 3 and 4. IIf~clean sands are encountered it
may be possible to reduce the absorption area requirements.
Test Hole ~3
9epth in Feet
From To
0.0' 8.0'
Table A
WO ~A18753
Logged By: Client
Date: 10-28-78
Soil Description
Peat, wet.
Bottom of Test Hole:
Frost Line:
Free Water Level:
Remarks:
8o0I
None Observed
None Observed
Hole filled with water and snow when
observed by Alaska Testlabo
Test Hole #4
pepth in Feet
From To
0.0' -- 1.0'
1.0' - 3.0'
3.0' - 8.0'
Table A
WO %A18753
Logged By: Client
Date: 10-28-78
Soil Description
Organic Topsoil.
Silty ~and~ Gravel, GM - F-l, damp.
Fine Gravelly Silty Sands, SM - F-2/F-3,
damp.
Bottom of Test Hole:
Frost Line:
Free Water Level:
Remarks:
8.0t
None Observed
None Observed
Test Hole Logged By Client
Verified by Alaska Testtab
.
LOT 2, BLOCK
Soils and Ground Water
Test Pit 21 was excavated on this lot in 1978. The pit was in
relatively clean gravels and sands and Test Pit 21 encountered
eight feet of sandy gravel, overlying gravelly silt. No ground
water was encountered.
Based on these test pits and information from adjacent lots, it
appears that two geologic units are present on the lot. The
upper part of the lot is the glacial unit "gm" (glacial till) and
the lower terraces are probably kame terraces deposited by water
flowing along the edge of the glacier as it retreated. Test
Pit 21 appears to be on the border between the landform units.
These terrace deposits are cleaner and more sorted than the till
deposits.
Location of Septic System
The recommended location for the septic system is on the lower
(southwest) portion of the lot on the terraces. Soils on the
higher part of the lot are less permeable and possibly have a
'high water level due to downslope seepage.
pesign Absorption Area
Based on the information available, it is recommended that the
system be designed for 1~0 square feet of absorption area per
bedroom provided clean gravel or sand (less than 10 percent silt)
is encountered.
Test Hole
~epth in Feet
From To
0.0' - 2.0'
2.0' - 8,.0'
8.0'- 12.0'
Table A
WO %A18753
Logged By: J.D. Mack
Date: 1-9-79
Soil Description
Topsoil.
Sand~ Gravel with cobbles to 8 inches, G~,
Gravell~ Silt, MI,, F-4, damp.
Bottom of Test Hole:
Frost Line:
Free Water Level:
12.0'
None Observed
None Observed
Sample Depth M%
1 2.0'- 8.0' 5.4
2 8.0'-12.0' 12.2
Type of Dry
Sample Strength Group Unified
G None C GW
G Slight D ML
Remarks: 1.
3.
4.
5.
6.
Type of Sample, G=Grab, SP = Standard Penetration,
U = undisturbed.
Dry Strength, N=None, L=Low, M=Medium, H=High.
Group refers to similar material, this study only.
General Info,nation, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
.I
I
I
1i
~'~T ',lll"r Ii i ~i "
~iii i~ii ii17'~' "" '~ ' "'
~-, ~ !, , · ~
I,~, ~
iil
IIII I!¥1 ..... I
:,, ~ ~', .: ,~,
,, ~1 ./~1
'" "' ':" 'l
il! ,, , ,' ,,~,
.I